RUGGEDCOM Modules. Preface. Introduction 1. Power Supply Modules 2. Copper Ethernet Modules 3. Fiber Optic Ethernet Modules 4.

Size: px
Start display at page:

Download "RUGGEDCOM Modules. Preface. Introduction 1. Power Supply Modules 2. Copper Ethernet Modules 3. Fiber Optic Ethernet Modules 4."

Transcription

1 Preface Introduction 1 RUGGEDCOM Modules Power Supply Modules 2 Copper Ethernet Modules 3 Fiber Optic Ethernet Modules 4 Serial Modules 5 Control Modules 6 Switch Modules 7 Network Redundancy Modules 8 Blank Modules 9 For MX5000RE 06/2018 RC1333-EN-03

2 RUGGEDCOM Modules Copyright 2018 Siemens Canada Ltd All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of Siemens Canada Ltd. Disclaimer Of Liability Siemens has verified the contents of this document against the hardware and/or software described. However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this material. The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice. Registered Trademarks RUGGEDCOM and ROS are trademarks of Siemens Canada Ltd. Linux is the registered trademark of Linus Torvalds in the United States and other countries. The registered trademark Linux is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a world-wide basis. Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner. Security Information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit support.automation.siemens.com. Warranty For warranty details, visit or contact a Siemens customer service representative. Contacting Siemens Address Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7 Telephone Toll-free: Tel: Fax: ruggedcom.info.i-ia@siemens.com Web ii

3 RUGGEDCOM Modules Table of Contents Table of Contents Preface... v Alerts... v Related Documents... vi Training... vi Customer Support... vi Ordering RUGGEDCOM Products... vii Chapter 1 Introduction Available Modules Installing/Removing Modules Dimensions... 7 Chapter 2 Power Supply Modules RUGGEDCOM MX5000REPN PS MHIF Chapter 3 Copper Ethernet Modules RUGGEDCOM MX5000REPN LM M4CG RUGGEDCOM MX5000REPN LM M8TX RUGGEDCOM MX5000REPN LM M12TX Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM MX5000REPN LM M4FG RUGGEDCOM MX5000REPN LM M4FG RUGGEDCOM MX5000REPN LM M4FX RUGGEDCOM MX5000REPN LM M8FX Chapter 5 Serial Modules RUGGEDCOM MX5000REPN LM MS iii

4 Table of Contents RUGGEDCOM Modules Chapter 6 Control Modules RUGGEDCOM MX5000REPN MCM01 L3SEL3HW RUGGEDCOM MX5000REPN CM01 L3SECL3HW Chapter 7 Switch Modules RUGGEDCOM MX5000REPN MSM RUGGEDCOM MX5000REPN SM MSM RUGGEDCOM MX5000REPN SM MSM Chapter 8 Network Redundancy Modules RUGGEDCOM MX5000REPN LM MPRP Chapter 9 Blank Modules RUGGEDCOM MX5000REPN PS XX RUGGEDCOM MX5000REPN LM XX iv

5 RUGGEDCOM Modules Preface Preface This document details RUGGEDCOM power and line modules available for use with devices in the RUGGEDCOM MX5000RE series of multi-service routers and switches. It is intended for use by network technical support personnel responsible for the installation, commissioning and maintenance of routers and switches. It is also recommended for use by network and system planners, system programmers, and line technicians. CONTENTS Alerts Related Documents Training Customer Support Ordering RUGGEDCOM Products Alerts The following types of alerts are used when necessary to highlight important information. DANGER! DANGER alerts describe imminently hazardous situations that, if not avoided, will result in death or serious injury. WARNING! WARNING alerts describe hazardous situations that, if not avoided, may result in serious injury and/or equipment damage. CAUTION! CAUTION alerts describe hazardous situations that, if not avoided, may result in equipment damage. IMPORTANT! IMPORTANT alerts provide important information that should be known before performing a procedure or step, or using a feature. NOTE NOTE alerts provide additional information, such as facts, tips and details. Alerts v

6 Preface RUGGEDCOM Modules Related Documents Other documents that may be of interest include: RUGGEDCOM MX5000RE Installation Guide Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs, experience and application. Siemens' Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastructure technologies. Siemens' unique mix of IT/Telecommunications expertise combined with domain knowledge in the utility, transportation and industrial markets, allows Siemens to provide training specific to the customer's application. For more information about training services and course availability, visit or contact a Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit to submit a Support Request (SR) or check on the status of an existing SR. Telephone Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple ios or Windows mobile device and be able to: Access Siemens' extensive library of support documentation, including FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales, Technical Support, Training, etc. Ask questions or share knowledge with fellow Siemens customers and the support community vi Related Documents

7 RUGGEDCOM Modules Preface Ordering RUGGEDCOM Products Use the RUGGEDCOM-Selector to select and configure RUGGEDCOM products and accessories. Once selected, an item(s) can be transferred to the Siemens Industry Mall and ordered. RUGGEDCOM-Selector For more information, refer to Ordering RUGGEDCOM Products vii

8 Preface RUGGEDCOM Modules viii Ordering RUGGEDCOM Products

9 RUGGEDCOM Modules Chapter 1 Introduction Introduction This catalog details the various power and line modules available for the RUGGEDCOM MX5000RE. Modules allow network designers to quickly and cost effectively adjust their communications infrastructure to the needs of the facilities and the network. It is intended to be used as a supplement to the Installation Guide for the device: RUGGEDCOM MX5000RE Installation Guide IMPORTANT! Only qualified personnel should be allowed to install and work on this equipment. Qualified persons in the sense of the safety-related notices in this manual are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards. CONTENTS Section 1.1, Available Modules Section 1.2, Installing/Removing Modules Section 1.3, Dimensions 1

10 Chapter 1 Introduction RUGGEDCOM Modules Section 1.1 Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM MX5000RE. NOTE All modules are conformal coated. Power Supply Modules RUGGEDCOM MX5000REPN PS MHIF Specifications Input Range: 88 to 300 VDC or 85 to 264 VAC Terminal Type: Terminal located on chassis Article Numbers 6GK6050-0RL16-0AA1 Copper Ethernet Modules RUGGEDCOM MX5000REPN LM M4CG02 Specifications Ports: 4 Speed: 1000 Mbps Interface: TX Connector: Micro-D Article Numbers 6GK6050-0ML20-0FD1 (Module) 6GK6050-0RL20-0FD1 (Module with Patch Panel and Cables) 6GK6050-0AR00-4RD0 (Patch Panel and Cables) RUGGEDCOM MX5000REPN LM M8TX02 Specifications Ports: 8 Speed: 100 Mbps Interface: TX Connector: Micro-D Article Numbers 6GK6050-0ML20-0ND1 (Module) 6GK6050-0RL20-0ND1 (Module with Patch Panel and Cables) 6GK6050-0AR00-8RD0 (Patch Panel and Cables) RUGGEDCOM MX5000REPN LM M12TX01 Specifications Ports: 12 Speed: 100 Mbps Interface: TX Connector: RJ45 Article Numbers 6GK6050-0ML20-0NB1 (Module) 6GK6050-0RL20-0NE1 (Module with Patch Panel and Cables) 6GK6050-0AR00-6RR0 (Patch Panel and Cables) Fiber Optic Ethernet Modules RUGGEDCOM MX5000REPN LM M8FX11 Specifications Mode: MM Speed: 100 Mbps Interface: FX Ports: 8 Connector: LC Article Numbers 6GK6050-0ML20-0BD1 (Module) 6GK6050-0RL20-0BD1 (Module with Patch Panel and Cables) 6GK6050-0AR00-8MM0 (Patch Panel and Cables) 2 Available Modules

11 RUGGEDCOM Modules Chapter 1 Introduction RUGGEDCOM MX5000REPN LM M4FX11 RUGGEDCOM MX5000REPN LM M4FG01 RUGGEDCOM MX5000REPN LM M4FG03 Distance: 2 km (1.2 mi) Specifications Mode: MM Speed: 100 Mbps Interface: FX Ports: 4 Connector: LC Distance: 2 km (1.2 mi) Specifications Mode: MM Speed: 1000 Mbps Interface: SX Wavelength: 850 nm Ports: 4 Connector: LC Distance: 500 m (1640 ft) Specifications Mode: SM Speed: 1000 Mbps Interface: LX Wavelength: 1310 nm Ports: 4 Connector: LC Distance: 10 Km (6 mi) Article Numbers 6GK6050-0ML20-0BH1 (Module) 6GK6050-0RL20-0BH1 (Module with Patch Panel and Cables) 6GK6050-0AR00-4MM0 (Patch Panel and Cables) Article Numbers 6GK6050-0ML20-0BK1 (Module) 6GK6050-0RL20-0BK1 (Module with Patch Panel and Cables) 6GK6050-0AR00-4MM0 (Patch Panel and Cables) Article Numbers 6GK6050-0ML20-0CR1 (Module) 6GK6050-0RL20-0CR1 (Module with Patch Panel and Cables) 6GK6050-0AR00-4SM0 (Patch Panel and Cables) Serial Modules RUGGEDCOM MX5000REPN LM MS01 Specifications Standard: RS232/RS422/RS485 Ports: 8 Connector: DB9 Article Numbers 6GK6050-0ML20-0KB1 (Module) 6GK6050-0RL20-0KB1 (Module with Patch Panel and Cables) 6GK6050-0AR00-8DR0 (Patch Panel and Cables) Control Modules RUGGEDCOM MX5000REPN MCM01 L3SEL3HW Specifications Layer 3 Standard Edition, Layer 3 Hardware Article Numbers 6GK6050-0ML30-0BA1 (Module) 6GK6050-0RL30-0BA1 (Module with Patch Panel and Cables) 6GK6050-0AR00-1CP0 (Patch Panel and Cables) Available Modules 3

12 Chapter 1 Introduction RUGGEDCOM Modules RUGGEDCOM MX5000REPN MCM01 L3SECL3HW Specifications Layer 3 Security Edition, Layer 3 Hardware Article Numbers 6GK6050-0ML30-0CA1 (Module) 6GK6050-0RL30-0CA1 (Module with Patch Panel and Cables) 6GK6050-0AR00-1CP0 (Patch Panel and Cables) Switch Modules RUGGEDCOM MX5000REPN MSM36 RUGGEDCOM MX5000REPN MSM61 Specifications Mode: SM Speed: 1000 Mbps Interface: LX Wavelength: 1310 nm Ports: 2 Connector: LC Distance: 10 Km (6 mi) Specifications Layer 3 Article Numbers 6GK6050-0ML40-0RA1 (Module) 6GK6050-0RL40-0RA1 (Module with Patch Panel and Cables) 6GK6050-0AR00-1SP0 (Patch Panel and Cables) Article Numbers 6GK6050-0ML40-0VA1 (Module) 6GK6050-0RL40-0VA1 (Module with Patch Panel and Cables) 6GK6050-0AR00-0XF0 (Patch Panel and Cables) RUGGEDCOM MX5000REPN MSM70 Specifications SFP Sockets: 2 Speed: 10 Gbps Network Layer: Layer 3 Article Numbers 6GK6050-0ML40-0XA1 (Module) 6GK6050-0RL40-0WA1 (Module with Patch Panel and Cables) 6GK6050-0AR00-1SP0 (Patch Panel and Cables) Network Redundancy Modules RUGGEDCOM MX5000REPN LM MPRP Specifications Ports: 2 Speed: 1000 Mbps Interface: LX Port Type: RJ45 Distance: 10 km (6.2 mi) Protocol: PRP Article Numbers 6GK6050-0ML20-0PR1 (Module) 6GK6050-0RL20-0PR1 (Module with Patch Panel and Cables) 6GK6050-0AR00-2PR0 (Patch Panel and Cables) 4 Available Modules

13 RUGGEDCOM Modules Chapter 1 Introduction Blank Modules RUGGEDCOM MX5000REPN PS XX Specifications Blank power supply module, full panel Article Numbers 6GK6050-0RL10-0AA1 RUGGEDCOM MX5000REPN LM XX Specifications Blank line module, half panel Article Numbers 6GK6050-0RL20-0AA1 Available Modules 5

14 Chapter 1 Introduction RUGGEDCOM Modules Section 1.2 Installing/Removing Modules Always refer to the Installation Guide for the RUGGEDCOM MX5000RE for instructions on how to install or remove a power or line module. The Installation Guide cites important, chassis-specific safety warnings that should be followed to avoid damage to the module and/or device. Additional installation/removal instructions may also be provided in this for select modules. Make sure to review all information provided for a module before installing or removing it. 6 Installing/Removing Modules

15 RUGGEDCOM Modules Chapter 1 Introduction Section 1.3 Dimensions Power and line modules conform to the following dimensions: NOTE All dimensions are in millimeters (mm) Figure 1: Power and Line Module Dimensions Dimensions 7

16 Chapter 1 Introduction RUGGEDCOM Modules 8 Dimensions

17 RUGGEDCOM Modules Chapter 2 Power Supply Modules Power Supply Modules The following power supply modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 2.1, RUGGEDCOM MX5000REPN PS MHIF 9

18 Chapter 2 Power Supply Modules RUGGEDCOM Modules Section 2.1 RUGGEDCOM MX5000REPN PS MHIF The RUGGEDCOM MX5000REPN PS MHIF power supply module provides high VDC or VAC power to the RUGGEDCOM MX5000RE and features a failsafe relay to protect against critical error conditions. The module accepts either AC or DC power inputs from an external power supply. IMPORTANT! The required power input for the RUGGEDCOM MX5000REPN PS MHIF is located on the chassis. For more information about the RUGGEDCOM MX5000RE chassis options, refer to Article Number 6GK6050-0MB00-0AG1 and 6GK6050-0MB00-0AG2. LEDs indicate when the module is receiving and supplying power. LED State Description O Green The module is supplying power I Green The module is receiving power 1 2 Figure 2: RUGGEDCOM MX5000REPN PS MHIF 1. I LED 2. O LED Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Characteristics Environment Input Range 88 to 300 VDC or 85 to 264 VAC Ingress Protection IP30 Internal Fuse Rating 6.3 A, 250 V(T) a Operating Temperature -40 to 85 C (-40 to 185 F) Maximum Power Consumption b Insulation 84 W c 2800 VDC for 1 minute Operating Relative Humidity Storage Temperature 5 to 95% (non-condensing) -40 to 85 C (-40 to 185 F) a (T) denotes time-delay fuse. Internal fuse is not user-replaceable. b Power consumption varies based on the device configuration. c Rating at 85 C (185 F) ambient temperature at worst-case load. Ordering Information Description Article Numbers VDC or VAC, supports terminal block on front. 6GK6050-0RL16-0AA1 10 RUGGEDCOM MX5000REPN PS MHIF

19 RUGGEDCOM Modules Chapter 3 Copper Ethernet Modules Copper Ethernet Modules The following copper Ethernet modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 3.1, RUGGEDCOM MX5000REPN LM M4CG02 Section 3.2, RUGGEDCOM MX5000REPN LM M8TX02 Section 3.3, RUGGEDCOM MX5000REPN LM M12TX01 11

20 Chapter 3 Copper Ethernet Modules RUGGEDCOM Modules Section 3.1 RUGGEDCOM MX5000REPN LM M4CG02 The RUGGEDCOM MX5000REPN LM M4CG02 module features four 10/100/1000Base-TX Micro-D ports. IMPORTANT! This module is only compatible with RUGGEDCOM MX5000REPN SM 61. Each port features a dedicated LED that indicates its link/activity state. State Description 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected Figure 3: RUGGEDCOM MX5000REPN LM M4CG02 1. Alarm LED 2. Micro-D Ports 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Pin-Out Description The following are the pin-out descriptions for the Micro-D ports: Pin 10/100Base-TX 1000Base-TX 1 1 TX+ B+ 2 Reserved (Do Not Connect) D+ 3 Reserved (Do Not Connect) 4 Reserved (Do Not Connect) C+ 6 Figure 4: Micro-D 10/100Base-TX Port Pin Configuration 5 RX+ A+ 6 TX- B- 7 Reserved (Do Not Connect) D- 8 Reserved (Do Not Connect) C- 9 RX- A- 12 RUGGEDCOM MX5000REPN LM M4CG02

21 RUGGEDCOM Modules Chapter 3 Copper Ethernet Modules Technical Specifications Characteristics Environment Speed 10/100/1000 Mbps Ingress Protection IP40 Interface TX Operating Temperature -40 to 85 C (-40 to 185 F) Connector Micro-D Operating Relative Humidity 5 to 95% (non-condensing) Cable Type > CAT-5 Storage Temperature -40 to 85 C (-40 to 185 F) Duplex FDX/HDX Wiring Standard TIA/EIA T568A/B Nominal Distance 100 m (328.1 ft) Isolation 1.5 kv Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 4 x 10/100/1000TX Micro-D 6GK6050-0ML20-0FD1 Module with Patch Panel and Cables 4 x 10/100/1000TX Micro-D 6GK6050-0RL20-0FD1 Patch Panel and Cables 4 x Micro-D connectors to RJ45 connectors 6GK6050-0AR00-4RD0 RUGGEDCOM MX5000REPN LM M4CG02 13

22 Chapter 3 Copper Ethernet Modules RUGGEDCOM Modules Section 3.2 RUGGEDCOM MX5000REPN LM M8TX02 The RUGGEDCOM MX5000REPN LM M8TX02 module features eight 10/100Base-TX Micro-D ports. Each port features a dedicated LED that indicates its link/activity state. State Description 2 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected 1 3 Figure 5: RUGGEDCOM MX5000REPN LM M8TX02 1. Alarm LED 2. Port LEDs 3. Micro-D Ports Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Pin-Out Description The following are the pin-out descriptions for the Micro-D ports: Pin 10/100Base-TX 1000Base-TX 1 1 TX+ B+ 2 Reserved (Do Not Connect) D+ 3 Reserved (Do Not Connect) 4 Reserved (Do Not Connect) C+ 6 Figure 6: Micro-D 10/100Base-TX Port Pin Configuration 5 RX+ A+ 6 TX- B- 7 Reserved (Do Not Connect) D- 8 Reserved (Do Not Connect) C- 9 RX- A- Technical Specifications Characteristics Environment 14 RUGGEDCOM MX5000REPN LM M8TX02

23 RUGGEDCOM Modules Chapter 3 Copper Ethernet Modules Speed 10/100 Mbps Ingress Protection IP40 Interface TX Operating Temperature -40 to 85 C (-40 to 185 F) Connector Micro-D Operating Relative Humidity 5 to 95% (non-condensing) Duplex FDX/HDX Storage Temperature -40 to 85 C (-40 to 185 F) Cable Type > CAT-5 Wiring Standard TIA/EIA T568A/B Nominal Distance 100 m (328.1 ft) Isolation 1.5 kv Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 8 x 10/100Base-TX Micro-D 6GK6050-0ML20-0ND1 Module with Patch Panel and Cables 8 x 10/100Base-TX Micro-D 6GK6050-0RL20-0ND1 Patch Panel and Cables 8 x Micro-D connectors to RJ45 connectors 6GK6050-0AR00-8RD0 RUGGEDCOM MX5000REPN LM M8TX02 15

24 Chapter 3 Copper Ethernet Modules RUGGEDCOM Modules Section 3.3 RUGGEDCOM MX5000REPN LM M12TX01 The RUGGEDCOM MX5000REPN LM M12TX01 module features sixteen 10/100 Base-TX RJ45 ports, but only twelve ports are connected to the RUGGEDCOM MX5000RE enclosure via the associated patch panel. The module features two dedicated LEDs to indicate link/activity state. LED State Description 2 3 Speed Yellow The port is operating at 1000 Mbps Off The port is operating at 10 or 100 Mbps Link/Activity Yellow (Solid) Link established Yellow (Blinking) Activity 1 4 Off No link detected Figure 7: RUGGEDCOM MX5000REPN LM M12TX01 1. Alarm LED 2. Speed LED 3. Link/Activity LED 4. Ethernet Ports Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Pin-Out Description The following are the pin-out descriptions for the RJ45 ports: 8 1 Pin 10/100Base-TX Name 1000Base-TX Description 1 RX+ BI_DB+ Receive Data+ or Bi-Directional Figure 8: RJ45 Ethernet Port Pin Configuration 2 RX- BI_DB- Receive Dataor Bi-Directional 3 TX+ BI_DA+ Transmit Data+ or Bi-Directional 4 Reserved (Do Not Connect) 5 Reserved (Do Not Connect) 6 TX- BI_DA- Transmit Dataor Bi-Directional 7 Reserved (Do Not Connect) 8 Reserved (Do Not Connect) 16 RUGGEDCOM MX5000REPN LM M12TX01

25 RUGGEDCOM Modules Chapter 3 Copper Ethernet Modules Technical Specifications Characteristics Environment Speed 10/100 Mbps Ingress Protection IP40 Interface TX Operating Temperature -40 to 85 C (-40 to 185 F) Connector RJ45 Operating Relative Humidity 5 to 95% (non-condensing) Cable Type > CAT-5 Storage Temperature -40 to 85 C (-40 to 185 F) Duplex FDX/HDX Wiring Standard TIA/EIA T568A/B Nominal Distance 100 m (328.1 ft) Isolation 1.5 kv Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 16 x 10/100Base-TX RJ45 6GK6050-0ML20-0NB1 Module with Patch Panel and Cables 12 x 10/100Base-TX RJ45 6GK6050-0RL20-0NE1 Patch Panel and Cables 12 x RJ45 connectors to RJ45 connectors 6GK6050-0AR00-6RR0 RUGGEDCOM MX5000REPN LM M12TX01 17

26 Chapter 3 Copper Ethernet Modules RUGGEDCOM Modules 18 RUGGEDCOM MX5000REPN LM M12TX01

27 RUGGEDCOM Modules Chapter 4 Fiber Optic Ethernet Modules Fiber Optic Ethernet Modules The following fiber optic Ethernet modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 4.1, RUGGEDCOM MX5000REPN LM M4FG01 Section 4.2, RUGGEDCOM MX5000REPN LM M4FG03 Section 4.3, RUGGEDCOM MX5000REPN LM M4FX11 Section 4.4, RUGGEDCOM MX5000REPN LM M8FX11 19

28 Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM Modules Section 4.1 RUGGEDCOM MX5000REPN LM M4FG01 The RUGGEDCOM MX5000REPN LM M4FG01 module features four 1000Base-SX fiber optic Ethernet ports. IMPORTANT! This module is only compatible with RUGGEDCOM MX5000REPN SM 61. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state. State Description 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected Figure 9: RUGGEDCOM MX5000REPN LM M4FG01 1. Alarm LED 2. Ethernet Ports 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -9 to -2.5 dbm Speed 1 Gbps Receiver Sensitivity -20 dbm Mode MM (Multi-Mode) Receiver Saturation 0 dbm Interface SX Power Budget 11 db Connector LC Environment Ingress Protection Operating Temperature IP40-40 to 85 C (-40 to 185 F) Cable Type Wavelength a Nominal Distance a 62.5/125 μm 850 nm 0.5 km (0.3 mi) Operating Relative Humidity 5 to 95% (non-condensing) 20 RUGGEDCOM MX5000REPN LM M4FG01

29 RUGGEDCOM Modules Chapter 4 Fiber Optic Ethernet Modules Storage Temperature -40 to 85 C (-40 to 185 F) a Typical. Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 4 x 1000SX, Multimode, 850nm, LC, 500m 6GK6050-0ML20-0BK1 Module with Patch Panel and Cables 4 x 1000SX, Multimode, 850nm, LC, 500m 6GK6050-0RL20-0BK1 Patch Panel and Cables 4 x Multi Mode Military Circular Fiber Connectors with LC connectors 6GK6050-0AR00-4MM0 RUGGEDCOM MX5000REPN LM M4FG01 21

30 Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM Modules Section 4.2 RUGGEDCOM MX5000REPN LM M4FG03 The RUGGEDCOM MX5000REPN LM M4FG03 module features four 1000Base-LX fiber optic Ethernet ports. IMPORTANT! This module is only compatible with RUGGEDCOM MX5000REPN SM 61. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state. State Description 1 Green (Solid) Green (Blinking) Off Link established Activity No link detected 2 2 Figure 10: RUGGEDCOM MX5000REPN LM M4FG03 1. Ethernet Ports 2. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -9.5 to -3 dbm Speed 1000Base-LX Receiver Sensitivity -21 dbm Mode Single-Mode Receiver Saturation -3 dbm Interface LC Power Budget 11.5 db Cable Type 9/125 μm Environment Ingress Protection IP40 Wavelength b Nominal Distance a 1310 nm 10 km (6.2 mi) Operating Temperature -40 to 85 C (-40 to 185 F) Operating Relative Humidity 5 to 95% (non-condensing) 22 RUGGEDCOM MX5000REPN LM M4FG03

31 RUGGEDCOM Modules Chapter 4 Fiber Optic Ethernet Modules Storage Temperature -40 to 85 C (-40 to 185 F) b Typical. Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 4x 1000LX Singlemode, 1310nm, LC, 10km 6GK6050-0ML20-0CR1 Module with Patch Panel and Cables 4x 1000LX Singlemode, 1310nm, LC, 10km 6GK6050-0RL20-0CR1 Patch Panel and Cables 4 x Single Mode Military Circular Fiber Connectors with LC connectors 6GK6050-0AR00-4SM0 RUGGEDCOM MX5000REPN LM M4FG03 23

32 Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM Modules Section 4.3 RUGGEDCOM MX5000REPN LM M4FX11 The RUGGEDCOM MX5000REPN LM M4FX11 module features four 100Base-FX fiber optic Ethernet ports. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state. State Description 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected Figure 11: RUGGEDCOM MX5000REPN LM M4FX11 1. Alarm LED 2. Ethernet Ports 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -19 to -14 dbm Speed 100 Mbps Receiver Sensitivity -32 dbm Mode MM (Multi-Mode) Receiver Saturation -14 dbm Interface FX Power Budget 13 db Connector LC Environment Ingress Protection Operating Temperature IP40-40 to 85 C (-40 to 185 F) Cable Type Wavelength c Nominal Distance a 62.5/125 μm 1300 nm 2 km (1.2 mi) Operating Relative Humidity 5 to 95% (non-condensing) Storage Temperature -40 to 85 C (-40 to 185 F) c Typical. 24 RUGGEDCOM MX5000REPN LM M4FX11

33 RUGGEDCOM Modules Chapter 4 Fiber Optic Ethernet Modules Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 4 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0ML20-0BH1 Module with Patch Panel and Cables 4 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0RL20-0BH1 Patch Panel and Cables 4 x Multi Mode Military Circular Fiber Connectors with LC connectors 6GK6050-0AR00-4MM0 RUGGEDCOM MX5000REPN LM M4FX11 25

34 Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM Modules Section 4.4 RUGGEDCOM MX5000REPN LM M8FX11 The RUGGEDCOM MX5000REPN LM M8FX11 module features eight 100Base-FX fiber optic Ethernet ports. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state. State Description 1 Green (Solid) Green (Blinking) Off Link established Activity No link detected Figure 12: RUGGEDCOM MX5000REPN LM M8FX11 1. Ethernet Ports 2. Alarm LED 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -19 to -14 dbm Speed 100 Mbps Receiver Sensitivity -32 dbm Mode MM (Multi-Mode) Receiver Saturation -14 dbm Interface FX Power Budget 13 db Connector LC Environment Ingress Protection Operating Temperature IP40-40 to 85 C (-40 to 185 F) Cable Type Wavelength d Nominal Distance 62.5/125 μm 1300 nm 2 km (1.2 mi) Operating Relative Humidity 5 to 95% (non-condensing) Storage Temperature -40 to 85 C (-40 to 185 F) d Typical. 26 RUGGEDCOM MX5000REPN LM M8FX11

35 RUGGEDCOM Modules Chapter 4 Fiber Optic Ethernet Modules Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module 8 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0ML20-0BD1 Module with Patch Panel and Cables 8 x 100FX, Multimode, 1300nm, LC, 2km 6GK6050-0RL20-0BD1 Patch Panel and Cables 8 x Multi Mode Military Circular Fiber Connectors with LC connectors 6GK6050-0AR00-8MM0 RUGGEDCOM MX5000REPN LM M8FX11 27

36 Chapter 4 Fiber Optic Ethernet Modules RUGGEDCOM Modules 28 RUGGEDCOM MX5000REPN LM M8FX11

37 RUGGEDCOM Modules Chapter 5 Serial Modules Serial Modules The following serial modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 5.1, RUGGEDCOM MX5000REPN LM MS01 29

38 Chapter 5 Serial Modules RUGGEDCOM Modules Section 5.1 RUGGEDCOM MX5000REPN LM MS01 The RUGGEDCOM MX5000REPN LM MS01 module features eight serial DB9 ports that may be used with a null modem (crossover) serial cable. 2 1 Figure 13: RUGGEDCOM MX5000PN LM MS01 1. Alarm LED 2. Serial Ports Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Operating Modes Each serial port can be run in RS232, RS485 or RS422 mode. On initial power-up, all serial ports default to RS485 mode. However, each port can be individually set to RS232, RS485 or RS422 mode via RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM MX5000RE. Pin-Out Description The following are the pin-outs for the DB9 connectors: 5 1 Pin Function RS232 Mode RS422 Mode RS485 Mode Figure 14: DB9 Serial Port RX- 2 RX TX+ TX+/RX+ 3 TX RX+ 4 Reserved (Do Not Connect) 5 COM (Isolated GND) 6 COM (Isolated GND) 7 TX- TX-/RX- 8 Reserved (Do Not Connect) 30 RUGGEDCOM MX5000REPN LM MS01

39 RUGGEDCOM Modules Chapter 5 Serial Modules Pin Function RS232 Mode RS422 Mode RS485 Mode 9 COM (Isolated GND) Body Screws Chassis GND a Chassis GND a a Connected internally. Connecting to RS485 Devices Each RS485 port can communicate with multiple RS485 devices by wiring devices together in sequence over a single twisted pair with transmit and receive signals on the same two wires (half duplex). For reliable, continuous communication, adhere to the following guidelines: To minimize the effects of ambient electrical noise, use shielded cabling. The correct polarity must be observed throughout a single sequence or ring. The number of devices wired should not exceed 32, and total distance should be less than 1219 m (4000 ft) at 100 kbps. The Common terminals should be connected to the common wire inside the shield. The shield should be connected to earth ground at a single point to avoid loop currents. The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring < 1219 m (4000 in) 120Ω 10nF 6 120Ω 10nF Figure 15: Recommended RS485 Wiring 1. MX5000RE Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth (Connected At a Single Point) 6. RS485 Devices (32 Total) RUGGEDCOM MX5000REPN LM MS01 31

40 Chapter 5 Serial Modules RUGGEDCOM Modules Technical Specifications Characteristics Environment Baud Rate 1200 to kbps Ingress Protection IP40 Connector DB9 Operating Temperature -40 to 85 C (-40 to 185 F) Isolation 2.5 kv Operating Relative Humidity 5 to 95% (non-condensing) Storage Temperature -40 to 85 C (-40 to 185 F) Certification This module has been certified to comply with the requirements of the relevant standards. Category Standard EMC FCC Part 15 (Class A), EN (CISPR22 Class A), IEC , IEEE 1613 Safety UL , CSA C22.2 No Hazardous Location (CSA/UL) Class I, Div 2 Emitted Interference EN (Class A) Interference Immunity EN Railway EN 50155, EN Ordering Information Item Description Article Number Module Module with Patch Panel and Cables 8 x RS232/RS422/RS485 via DB9 Serial Line Module 8 x RS232/RS422/RS485 via DB9 Serial Line Module 6GK6050-0ML20-0KB1 6GK6050-0RL20-0KB1 Patch Panel and Cables Panels for MX5000RE Serial module. 6GK6050-0AR00-8DR0 32 RUGGEDCOM MX5000REPN LM MS01

41 RUGGEDCOM Modules Chapter 6 Control Modules Control Modules Control modules are the central processing engine for the device. The RUGGEDCOM ROX II operating system running on the module controls and coordinates the functions of all modules installed in the system. Each control module is equipped with an RS232 serial console port for initial management functions, and a locally connected 10/100Base-T Ethernet port for system management out-of-band from the switch fabric. Other features include: Alarm LED to indicate the system status Removable 1 GB Compact Flash (CF) card, which contains active and fallback installations of the RUGGEDCOM ROX II operating system, the configuration database, and other system data A failsafe alarm relay, activated by the operating system to indicate a critical alarm. A lamp test and alarm cutoff button A utility USB port for uploading/downloading files The following control modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 6.1, RUGGEDCOM MX5000REPN MCM01 L3SEL3HW Section 6.2, RUGGEDCOM MX5000REPN CM01 L3SECL3HW 33

42 Chapter 6 Control Modules RUGGEDCOM Modules Section 6.1 RUGGEDCOM MX5000REPN MCM01 L3SEL3HW The RUGGEDCOM MX5000REPN MCM01 L3SEL3HW control module features Layer 3 hardware and is preconfigured with RUGGEDCOM ROX II Layer 3 Standard Edition Figure 16: RUGGEDCOM MX5000REPN MCM01 L3SEL3HW 1. LT/ACO Button 2. CF Card Slot 3. Alarm LED 4. MGMT Port 5. USB Port 6. Console Port 7. Failsafe Relay Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Operating Temperature Operating Relative Humidity Storage Temperature -40 to 85 C (-40 to 185 F) 5 to 95% (non-condensing) -40 to 85 C (-40 to 185 F) Ordering Information Item Description Article Number Module Module with Patch Panel and Cables Control module with Layer 3 Standard Edition Layer 3 hardware Control module with Layer 3 Standard Edition Layer 3 hardware 6GK6050-0ML30-0BA1 6GK6050-0RL30-0BA1 Patch Panel and Cables Panels for MX5000RE Control Module 6GK6050-0AR00-1CP0 34 RUGGEDCOM MX5000REPN MCM01 L3SEL3HW

43 RUGGEDCOM Modules Chapter 6 Control Modules Section 6.2 RUGGEDCOM MX5000REPN CM01 L3SECL3HW The RUGGEDCOM MX5000REPN CM01 L3SECL3HW control module features Layer 3 hardware and is preconfigured with RUGGEDCOM ROX II Layer 3 Security Edition Figure 17: RUGGEDCOM MX5000REPN CM01 L3SECL3HW 1. LT/ACO Button 2. CF Card Slot 3. Alarm LED 4. MGMT Port 5. USB Port 6. Console Port 7. Failsafe Relay Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Operating Temperature Operating Relative Humidity Storage Temperature -40 to 85 C (-40 to 185 F) 5 to 95% (non-condensing) -40 to 85 C (-40 to 185 F) Ordering Information Item Description Article Number Module Module with Patch Panel and Cables Control module with Layer 3 Security Edition Layer 3 hardware Control module with Layer 3 Security Edition Layer 3 hardware 6GK6050-0ML30-0CA1 6GK6050-0RL30-0CA1 Patch Panel and Cables Panels for MX5000RE Control Module 6GK6050-0AR00-1CP0 RUGGEDCOM MX5000REPN CM01 L3SECL3HW 35

44 Chapter 6 Control Modules RUGGEDCOM Modules 36 RUGGEDCOM MX5000REPN CM01 L3SECL3HW

45 RUGGEDCOM Modules Chapter 7 Switch Modules Switch Modules Switch modules connect devices together on a computer network by using packet switching to receive, process and forward data to the destination device. The following switch modules are available for the RUGGEDCOM MX5000RE. CONTENTS Section 7.1, RUGGEDCOM MX5000REPN MSM36 Section 7.2, RUGGEDCOM MX5000REPN SM MSM61 Section 7.3, RUGGEDCOM MX5000REPN SM MSM70 37

46 Chapter 7 Switch Modules RUGGEDCOM Modules Section 7.1 RUGGEDCOM MX5000REPN MSM36 The RUGGEDCOM MX5000REPN MSM36 module features two 1000Base-LX fiber optic Ethernet ports. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each port set (transmit/receive) features a dedicated LED that indicates its link/activity state. State Description 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected 1 3 Figure 18: RUGGEDCOM MX5000REPN MSM36 1. Alarm LED 2. Ethernet Ports 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -10 to -3 dbm Speed 1 Gbps Receiver Sensitivity -20 dbm Mode SM (Single-Mode) Receiver Saturation -3 dbm Interface LX Power Budget 10 db Connector LC Environment Operating Temperature Operating Relative Humidity Storage Temperature a Typical. -40 to 85 C (-40 to 185 F) 5 to 95% (non-condensing) -40 to 85 C (-40 to 185 F) Cable Type 9/125 μm Wavelength a 1310 Nominal Distance a 10 km (6.2 mi) 38 RUGGEDCOM MX5000REPN MSM36

47 RUGGEDCOM Modules Chapter 7 Switch Modules Ordering Information Item Description Article Number Module 2x 1000LX singlemode, 1310nm, LC, 10km 6GK6050-0ML40-0RA1 Module with Patch Panel and Cables Patch Panel and Cables 2x 1000LX singlemode, 1310nm, LC, 10km 2 x Singlemode Military Circular Fiber Connectors with LC connectors 6GK6050-0RL40-0RA1 6GK6050-0AR00-1SP0 RUGGEDCOM MX5000REPN MSM36 39

48 Chapter 7 Switch Modules RUGGEDCOM Modules Section 7.2 RUGGEDCOM MX5000REPN SM MSM61 The RUGGEDCOM MX5000REPN SM MSM61 is a Layer 3/88 Gigabit throughput switch module that enables Gigabit throughput for up to 24 fiber optic Ethernet ports. 1 Figure 19: RUGGEDCOM MX5000REPN SM MSM61 1. Alarm LED Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Operating Temperature -40 to 85 C (-40 to 185 F) Ordering Information Item Description Article Number Module Module with Patch Panel and Cables Layer 3/88 Gigabit Throughput, no uplink ports Layer 3/88 Gigabit Throughput, no uplink ports 6GK6050-0ML40-0VA1 6GK6050-0RL40-0VA1 Patch Panel and Cables Full Blank Panel 6GK6050-0AR00-0XF0 40 RUGGEDCOM MX5000REPN SM MSM61

49 RUGGEDCOM Modules Chapter 7 Switch Modules Section 7.3 RUGGEDCOM MX5000REPN SM MSM70 The RUGGEDCOM MX5000REPN SM MSM70 is a Layer 3/88 Gigabit throughput switch module that enables Gigabit throughput for up to 24 fiber optic Ethernet ports. It also features sockets for up to two Small Form-factor Pluggable (SFP) transceivers. NOTE When connecting cables, make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Each transceiver socket features a dedicated LED that indicates the link/activity state of the associated SFP transceiver. State Description 2 Green (Solid) Green (Blinking) Off Link established Activity No link detected 1 3 Figure 20: RUGGEDCOM MX5000REPN SM MSM70 1. Alarm LED 2. SFP Transceiver Sockets 3. Port LEDs This module is only compatible with the following fiber optic Ethernet modules: RUGGEDCOM MX5000REPN LM M8FX11 Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -8.2 to 0.5 dbm Speed 10 Gbps Tx Minimum OMA -5.2 Minimum Extinction Ratio 3.5 Receiver Sensitivity OMA (dbm) Stressed RX Sensitivity (dbm) Receiver Saturation (dbm) 0.5 Power Budget (db) 4.4 Mode Interface Connector Cable Type Wavelength Nominal Distance SM (Single-Mode) LR LC 9/125 μm 1310 nm 10 km (6.2 mi) RUGGEDCOM MX5000REPN SM MSM70 41

50 Chapter 7 Switch Modules RUGGEDCOM Modules Channel Insertion Loss (db) 5.1 Allocation for Penalties (db) 2.3 Environment Operating Temperature Operating Relative Humidity Storage Temperature -40 to 85 C (-40 to 185 F) 0 to 85% (non-condensing) -40 to 85 C (-40 to 185 F) Ordering Information Item Description Article Number Module Layer 3/88 Gigabit Throughput, 2x 10G 6GK6050-0ML40-0XA1 Module with Patch Panel and Cables Layer 3/88 Gigabit Throughput, 2x 10G 6GK6050-0RL40-0WA1 Patch Panel and Cables 2 x Singlemode Military Circular Fiber Connectors with LC connectors 6GK6050-0AR00-1SP0 42 RUGGEDCOM MX5000REPN SM MSM70

51 RUGGEDCOM Modules Chapter 8 Network Redundancy Modules Network Redundancy Modules The following modules provide network redundancy functionality for the RUGGEDCOM MX5000RE. CONTENTS Section 8.1, RUGGEDCOM MX5000REPN LM MPRP 43

52 Chapter 8 Network Redundancy Modules RUGGEDCOM Modules Section 8.1 RUGGEDCOM MX5000REPN LM MPRP The RUGGEDCOM MX5000REPN LM MPRP module enables the device the interact with a redundancy network using the Parallel Redundancy Protocol (PRP). The module features individual Ethernet ports for connecting to each side of the network. NOTE For more information about PRP, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM MX5000RE Figure 21: RUGGEDCOM MX5000REPN LM MPRP 1. Alarm LED 2. Ethernet Ports 3. Port LEDs Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Technical Specifications Optical Characteristics Cabling Transmit Power -9.5 to -3.0 dbm Speed 1 Gbps Receiver Sensitivity to -3.0 dbm Mode SM (Single-Mode) Power Budget 9.5 db Interface LX Environment Connector LC Operating Temperature Operating Relative Humidity Storage Temperature -40 to 85 C (-40 to 185 F) 5 to 95% (non-condensing) -40 to 85 C (-40 to 185 F) Cable Type Wavelength Nominal Distance 9/125 μm 1310 nm 10 km (6.2 mi) 44 RUGGEDCOM MX5000REPN LM MPRP

53 RUGGEDCOM Modules Chapter 8 Network Redundancy Modules Ordering Information Item Description Article Number Module Module with Patch Panel and Cables 1x Pair (A/B) Gigabit PRP with 2x single-mode LC 10km Conformal Coating 1x Pair (A/B) Gigabit PRP with 2x single-mode LC 10km Conformal Coating 6GK6050-0ML20-0PR1 6GK6050-0RL20-0PR1 Patch Panel and Cables Panels for MX500RE PRP module 6GK6050-0AR00-2PR0 RUGGEDCOM MX5000REPN LM MPRP 45

54 Chapter 8 Network Redundancy Modules RUGGEDCOM Modules 46 RUGGEDCOM MX5000REPN LM MPRP

55 RUGGEDCOM Modules Chapter 9 Blank Modules Blank Modules The following blank modules are available for the RUGGEDCOM MX5000RE. IMPORTANT! Blank modules should be installed in empty slots to prevent the ingress of dirt or debris in the chassis. CONTENTS Section 9.1, RUGGEDCOM MX5000REPN PS XX Section 9.2, RUGGEDCOM MX5000REPN LM XX 47

56 Chapter 9 Blank Modules RUGGEDCOM Modules Section 9.1 RUGGEDCOM MX5000REPN PS XX The RUGGEDCOM MX5000REPN PS XX is a blank module designed to occupy empty power supply module slots in the RUGGEDCOM MX5000RE chassis. Figure 22: RUGGEDCOM MX5000REPN PS XX Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Ordering Information Description Article Numbers Power Supply Blank Module, Full Panel 6GK6050-0RL10-0AA1 48 RUGGEDCOM MX5000REPN PS XX

57 RUGGEDCOM Modules Chapter 9 Blank Modules Section 9.2 RUGGEDCOM MX5000REPN LM XX The RUGGEDCOM MX5000REPN LM XX is a blank module designed to occupy empty line module slots in the RUGGEDCOM MX5000RE chassis. Figure 23: RUGGEDCOM MX5000REPN LM XX Installing the Module For information about installing this module, refer to the Installation Guide for the RUGGEDCOM MX5000RE. Ordering Information Description Article Numbers Blank Module 6GK6050-0RL20-0AA1 RUGGEDCOM MX5000REPN LM XX 49

58 Chapter 9 Blank Modules RUGGEDCOM Modules 50 RUGGEDCOM MX5000REPN LM XX

RUGGEDCOM WIN5158-V Accessories

RUGGEDCOM WIN5158-V Accessories Preface Introduction 1 RUGGEDCOM WIN5158-V Accessories Open-Ended Female Cables 2 to RJ45 Cables 3 to Cables 4 to Cigarette Lighter Plug Cables 5 Siemens 02/2016 Drives & PLCs RC1256-EN-01 Copyright 2016

More information

RUGGEDCOM SFP Transceivers

RUGGEDCOM SFP Transceivers Preface Introduction 1 RUGGEDCOM SFP Transceivers Copper SFP Transceivers 2 Fast Ethernet SFP Transceivers 3 Gigabit Ethernet SFP Transceivers 4 10-Gigabit Ethernet SFP+ Transceivers 5 Installation/Removal

More information

RUGGEDCOM RS900GP. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS900GP. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS900GP Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2013 Copyright 2013 Siemens AG All rights reserved.

More information

RUGGEDCOM i802. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM i802. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM i802 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 01/2016 RC1004-EN-03 Copyright 2016 Siemens Canada Ltd.

More information

RUGGEDCOM MX5000RE. Preface. Introduction 1. Installing the Device 2. Device Management 3. Modules 4. Technical Specifications 5. Installation Guide

RUGGEDCOM MX5000RE. Preface. Introduction 1. Installing the Device 2. Device Management 3. Modules 4. Technical Specifications 5. Installation Guide Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 07/2018 RC1060-EN-08 Copyright 2018 Siemens Canada Ltd All rights reserved. Dissemination

More information

RUGGEDCOM RS8000. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS8000. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS8000 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2014 RC1020-EN-02 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RSG2100 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 3/2015 RC1040-EN-05 Copyright 2015 Siemens Canada Ltd.

More information

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS900 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2014 RC1024-EN-02 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RP100. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RP100. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RP100 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2014 RC1011-EN-03 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RS401. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS401. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS401 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 09/2016 RC1017-EN-05 Copyright 2016 Siemens Canada Ltd

More information

RUGGEDCOM RSG2100P. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RSG2100P. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 Installing Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 09/2018 RC1041-EN-13 Copyright 2018 Siemens Canada Ltd All rights reserved.

More information

RUGGEDCOM RSG2300. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG2300. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RSG2300 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2013 Copyright 2013 Siemens AG All rights reserved.

More information

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS900 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 9/2013 Copyright 2013 Siemens AG All rights reserved.

More information

RUGGEDCOM RSG2200. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG2200. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RSG2200 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2013 Copyright 2013 Siemens AG All rights reserved.

More information

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX

More information

RUGGEDCOM RS400. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS400. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS400 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 9/2014 RC1016-EN-03 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RS950G. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS950G. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS950G Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 12/2015 RC1037-EN-04 Copyright 2015 Siemens Canada

More information

Rugged Communication RUGGEDCOM RST Layer 2 rack switch with 10 Gbit/s uplinks. Edition 01/2018. Brochure. siemens.

Rugged Communication RUGGEDCOM RST Layer 2 rack switch with 10 Gbit/s uplinks. Edition 01/2018. Brochure. siemens. Rugged Communication RUGGEDCOM RST2228 19 Layer 2 rack switch with 10 Gbit/s uplinks Brochure Edition 01/2018 siemens.com/rst2228 RUGGEDCOM RST2228 Contents Field-modular high port density rack switch

More information

RUGGEDCOM RMC. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RMC. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RMC Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 01/2017 RC1006-EN-05 RUGGEDCOM RMC Copyright 2017 Siemens

More information

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RMC30 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 01/2017 RC1008-EN-05 Copyright 2017 Siemens Canada Ltd

More information

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 12/2015 RC1040-EN-09 Copyright 2015 Siemens Canada Ltd. All rights reserved.

More information

RUGGEDCOM RS400. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS400. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS400 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 09/2016 RC1016-EN-05 Copyright 2016 Siemens Canada Ltd

More information

RUGGEDCOM RSG2300. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RSG2300. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 Installing Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1046-EN-12 Copyright 2018 Siemens Canada Ltd All rights reserved.

More information

RUGGEDCOM RSG920P. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG920P. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction RUGGEDCOM RSG920P Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 4/205 RC72-EN-0 Copyright 205 Siemens Canada Ltd. All

More information

RUGGEDCOM i802. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM i802. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM i802 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 07/2017 RC1004-EN-05 Copyright 2017 Siemens Canada Ltd

More information

RUGGEDCOM RS401. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RS401. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 RUGGEDCOM RS401 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1017-EN-08 Copyright 2018 Siemens Canada Ltd

More information

RUGGEDCOM RSL910. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RSL910. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 RUGGEDCOM RSL910 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 09/2018 RC1305-EN-07 RUGGEDCOM RSL910 Copyright 2018

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

RUGGEDCOM RS969. Preface. Introduction. Installing the Device. Communication Ports. Technical Specifications. Dimension Drawings. Installation Guide

RUGGEDCOM RS969. Preface. Introduction. Installing the Device. Communication Ports. Technical Specifications. Dimension Drawings. Installation Guide Preface Introduction 1 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Accessories 6 Certification 7 10/2013 Copyright 2013 Siemens AG All rights reserved.

More information

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RSG2100. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RSG2100 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 06/2017 RC1040-EN-10 Copyright 2017 Siemens Canada Ltd

More information

Siemens Distributor RUGGEDCOM RSG920P. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4

Siemens Distributor RUGGEDCOM RSG920P. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4 Preface Introduction RUGGEDCOM RSG920P Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 02/206 Siemens Distributor RC72-EN-04 Copyright 206

More information

RUGGEDCOM RS910W. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS910W. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2016 RC1031-EN-03 Copyright 2016 Siemens Canada Ltd All rights reserved.

More information

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RMC30 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2014 RC1008-EN-02 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RS416. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RS416. Preface. Introduction 1. Installing Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 RUGGEDCOM RS416 Installing Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1018-EN-08 Copyright 2018 Siemens Canada Ltd All

More information

Preface Introduction Installing the Device RUGGEDCOM RMC Communication Ports Technical Specifications Certification Installation Guide 07/2018

Preface Introduction Installing the Device RUGGEDCOM RMC Communication Ports Technical Specifications Certification Installation Guide 07/2018 Preface Introduction 1 RUGGEDCOM RMC Installing the Device 2 Communication Ports 3 Technical Specifications 4 Certification 5 07/2018 RC1006-EN-07 RUGGEDCOM RMC Copyright 2018 Siemens Canada Ltd All rights

More information

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,

More information

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options Features and Benefits The RuggedMC is an industrially hardened fiber optical media converter specifically designed to operate in harsh environments such as those found in electric utility substations and

More information

RUGGEDCOM RS416P. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS416P. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS416P Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 06/2015 RC1019-EN-03 Copyright 2015 Siemens Canada Ltd.

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Dimension Drawings 6 Certification 7 12/2017 Siemens Drives & PLCs RC1359-EN-01 Copyright

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM RMC30. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 RUGGEDCOM RMC30 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1008-EN-07 Copyright 2018 Siemens Canada Ltd

More information

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch Quick Start Guide Elinx ESW100 Series 5 and 8 port Unmanaged Ethernet Switch ESW100 Series Documentation Number: ESW100series-1112qsg International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone

More information

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch Quick Start Guide Elinx ESW200 Series 5 and 8 port Unmanaged Ethernet Switch ESW200 Series Documentation Number: ESW200series-1112qsg International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone

More information

RUGGEDCOM RS416. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS416. Preface. Introduction 1. Installing Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS416 Installing Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2013 RC1018-EN-02 Copyright 2014 Siemens Canada Ltd. All

More information

RUGGEDCOM i801. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM i801. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1003-EN-05 Copyright 2018 Siemens Canada Ltd All rights reserved.

More information

PT-7728/7828 Quick Installation Guide

PT-7728/7828 Quick Installation Guide PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

RUGGEDCOM RS950G. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS950G. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS950G Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 7/2014 RC1037-EN-02 Copyright 2014 Siemens Canada Ltd.

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

Installation Guide. RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7

Installation Guide. RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7 RuggedMC RMC20 Installation Guide RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7 Web: http://www.ruggedcom.com/ Tel: +1 905 856 5288 Fax: +1 905 856 1995 Toll Free: 1 888 264 0006

More information

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS900. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS900 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2016 RC1024-EN-03 Copyright 2016 Siemens Canada Ltd

More information

Industrial Gigabit Managed Ethernet Switch

Industrial Gigabit Managed Ethernet Switch HMG-828 HMG-828E Industrial Gigabit Managed Ethernet Switch Features High Performance Network Switching Technology Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3X, IEEE 802.1p, IEEE 802.1q, IEEE 802.1d,

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

RUGGEDCOM RS910W. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS910W. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS910W Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 6/2014 RC1031-EN-02 Copyright 2014 Siemens Canada Ltd.

More information

RUGGEDCOM RMC8388. Rugged Media Converter. siemens.com/rmc8000. Edition 10/2015. Brochure

RUGGEDCOM RMC8388. Rugged Media Converter. siemens.com/rmc8000. Edition 10/2015. Brochure RUGGEDCOM RMC8388 Rugged Media Converter Brochure Edition 10/2015 siemens.com/rmc8000 Overview The RUGGEDCOM RMC8388 is a rugged, small form factor time converter that can convert time signals between

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

ProCurve Switch 1400 Series

ProCurve Switch 1400 Series The ProCurve Switch 1400 series provides plug-and-play simplicity for high-bandwidth connectivity. The Switch 1400 series consists of two unmanaged switches. The ProCurve Switch 1400-24G is a 24-port 10/100/1000

More information

RUGGEDCOM RX1510. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RX1510. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction RUGGEDCOM RX50 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 2/203 RC055-EN-0 RUGGEDCOM RX50 Copyright 203 Siemens AG

More information

PTC-101 Quick Installation Guide

PTC-101 Quick Installation Guide PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

RUGGEDCOM i800. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5

RUGGEDCOM i800. Preface. Introduction 1. Installing the Device 2. Device Management 3. Communication Ports 4. Technical Specifications 5 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 07/2018 RC1002-EN-05 Copyright 2018 Siemens Canada Ltd All rights reserved.

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

RUGGEDCOM RS930L. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RS930L. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction 1 RUGGEDCOM RS930L Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 10/2013 Copyright 2013 Siemens AG All rights reserved.

More information

Features and Benefits. Certifications

Features and Benefits. Certifications IMC-101G Series Industrial Gigabit Ethernet-to-fiber media converters Features and Benefits 10/100/1000BaseT(X) and 1000BaseSFP slot supported Link Fault Pass-Through (LFPT) Power failure, port break alarm

More information

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification Product Overview Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification Description This switch version has been specially certified for applications in the area of

More information

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide First Edition, February 2012 2012 Moxa Inc. All rights reserved. P/N: 1802001016020 Overview Moxa Industrial Media Converter, which

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-P308 Series 8-port unmanaged Ethernet switches with 4 IEEE 802.3af PoE ports Features and Benefits 4 IEEE 802.3af-compliant PoE and Ethernet combo ports Up to 15.4 W output at 48 VDC per PoE port Intelligent

More information

Quick Start Guide. Physical Description. The Port Status LEDs

Quick Start Guide. Physical Description. The Port Status LEDs Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. Capable of operating at temperature extremes of -40 C to +75 C, this is the switch of choice

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RNA managed

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RNA managed Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RNA managed 6GK6095-0GS2.-... RUGGEDCOM RS950G Technical Data Product-type designation RUGGEDCOM

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

IMC-P111FX / IMC-P111P Series

IMC-P111FX / IMC-P111P Series DIN-Rail Ethernet to Fiber Media Converter v1.0 / Jan, 013 IMC-P111FX / IMC-P111P Series Features IEC 61850-3 Ethernet to fiber media converter with 1x10/100Base-T(X) to 1x100Base-FX fiber or 1x100Base-FX

More information

RUGGEDCOM NETCONF. Preface. Introduction 1. NETCONF Capabilities and Namespaces 2. NETCONF Sessions 3. Getting Data 4. Changing Configuration Data 5

RUGGEDCOM NETCONF. Preface. Introduction 1. NETCONF Capabilities and Namespaces 2. NETCONF Sessions 3. Getting Data 4. Changing Configuration Data 5 Preface Introduction 1 RUGGEDCOM NETCONF NETCONF Capabilities and Namespaces 2 NETCONF Sessions 3 Getting Data 4 Changing Configuration Data 5 RUGGEDCOM ROX II Actions 6 Examples 7 NETCONF XML Elements

More information

GigaVUE-2404 // Data Sheet

GigaVUE-2404 // Data Sheet Mgmt Console M/S Rdy 10/100/1000 PORTS (SFP) G1 G2 G3 G4 G1 G2 G3 G4 1 1 2 2 3 3 4 5 4 5 6 6 7 7 8 8 SLOT 2 PORTS 9 16 SLOT 1 PORTS G1-G4 PORTS 1-8 SLOT 3 PORTS 17 24 PS ALARM CUTOFF UP WHEN INSTALLED

More information

RuggedServer RS400 Family

RuggedServer RS400 Family RuggedServer RS400 Family 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch Installation Guide October 14, 2009 www.ruggedcom.com RuggedCom Inc. I 300 Applewood Cres., Unit 1,

More information

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax: TM TM TM www.is5com.com Industrial Gigabit Ethernet to Fiber Media Converter Features Converts x 0/00/000Base-T(X) RJ45 port to x 000Base- LX/SX Fiber port or x 000Base-X SFP port Supports Jumbo Frame

More information

IMC-21GA Quick Installation Guide

IMC-21GA Quick Installation Guide IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a

More information

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS, Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax 724-746-0746 56-80830BB-00 Rev A1 June 2007 JUNE 2007 LGC320A, LGC321A, LGC322A,

More information

KFC-200. Installation Guide

KFC-200. Installation Guide KFC-200 10/100BASE-TX to 100BASE-FX Media Converters Installation Guide DOC.121221-1- (C) 2011-2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or

More information

RUGGEDCOM RX1500. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5

RUGGEDCOM RX1500. Preface. Introduction 1. Installing the Device 2. Communication Ports 3. Technical Specifications 4. Dimension Drawings 5 Preface Introduction RUGGEDCOM RX500 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6 /204 RC053-EN-03 RUGGEDCOM RX500 Copyright 204 Siemens

More information

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M Gigabit Ethernet Switch With 10G Uplinks Hardware Manual MS400860M Gigabit Ethernet Switch with 10G Uplinks Hardware Manual II About This Guide Purpose Audience Conventions This guide details the hardware

More information

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Stride Industrial Ethernet Switches

Stride Industrial Ethernet Switches 8-Port Ethernet Switch with Fiber Port STRIDE Industrial Ethernet Switch with eight 10/100BaseT RJ45 Ethernet ports and one 100BaseFX Fiber optic port (ST type multimode fiber connector for links up to

More information

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2 Use with 0 to 70 C ambient temperature SIMATIC Preface 1 Product combination 2 Product family 3 Process Control System PCS 7 Use with 0 to 70 C ambient temperature System Manual 02/2015 A5E35458345-AA

More information

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE Product Overview Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE Description The 10 Port Gigabit Switch has two 1000Base-X fiber ports to build up fiber rings (fast redundancy)

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

IMC-P111FX Series IMC-P111P Series

IMC-P111FX Series IMC-P111P Series DIN-Rail Ethernet to Fiber Media Converter v.1 / Oct, 017 IMC-P111FX Series IMC-P111P Series IMC-P111FX Series IMC-P111P Series Features Designed for Railway application and fully compliant with the requirement

More information

6GK6091-0AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS910 managed

6GK6091-0AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS910 managed Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEOM Serial Device Servers > RUGGEOM RS910 managed 6GK6091-0AT2.-... RS910 Technical Data Product-type designation Product description

More information

RUGGEDCOM RSG907R & RSG909R. Compact multi-port IEEE 1588 switches with HSR and PRP support. Rugged Communication. Edition 01/2018.

RUGGEDCOM RSG907R & RSG909R. Compact multi-port IEEE 1588 switches with HSR and PRP support. Rugged Communication. Edition 01/2018. Rugged Communication RSG907R & RSG909R Compact multi-port IEEE 1588 switches with HSR and PRP support Brochure Edition 01/2018 siemens.com/rsg900r RSG907R & RSG909R Contents The RSG907R and RSG909R are

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP General The IP protocol has already left the in-house environment and is going to take all

More information

Gigabit Ethernet 10 port Industrial Switch with Ring redundancy

Gigabit Ethernet 10 port Industrial Switch with Ring redundancy Product Overview Gigabit Ethernet 10 port Industrial Switch with Ring redundancy Description The new 10 port Gigabit Switch is equipped with two 1000Base-SX/LX Gigabit Ethernet fiber optic interfaces and

More information

RUGGEDCOM RX1500. Preface. Introduction 1. Installing the Device 2. Device Management 3. Modules 4. Technical Specifications 5. Installation Guide

RUGGEDCOM RX1500. Preface. Introduction 1. Installing the Device 2. Device Management 3. Modules 4. Technical Specifications 5. Installation Guide Preface Introduction 1 RUGGEDCOM RX1500 Installing the Device 2 Device Management 3 Modules 4 Technical 5 Dimension Drawings 6 Certification 7 01/2018 RC1053-EN-08 Copyright 2018 Siemens Canada Ltd All

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX KGC-352 Series Installation Guide DOC.070820-KGC-352-1- (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation

More information