Installation Quick Reference Guide. BACnet Alarm v1.0

Size: px
Start display at page:

Download "Installation Quick Reference Guide. BACnet Alarm v1.0"

Transcription

1 Installation Quick Reference Guide BACnet Alarm v1.0

2 Contents User Responsibility 4 Introduction 5 Features 5 Description of BACnet Alarm 5 Shipment Details 5 The BACnet Alarm Back Box 5 The Frame Assembly 5 Description of Modules 6 System Power Supply 6 BASremote Master Device 6 BASremote Expansion Device 6 Installation 7 BACnet Alarm Box 7 Wiring 8 System Power Supply 8 BASremote Master/Expansion Device 8 Configuration 9-15 System Configuration 9-10 Web Configuration BASremote 11 Configure Settings 12 Reset IP Address on BASremote Master Device 13 Channel Type Change and Save: Channel Name, BASremote Unit Group/Value/Description Dimensions 16 Spare Part Numbers 16 Diagram A 17 BASremote Master Device 17 Diagram B 18 BASremote Expansion Device 18 Diagram C 19 Complete BACnet 19 2 Amico Corporation

3 Appendix A: Wiring Diagram Auto-Switch Power Supply 20 Appendix B: Wiring Diagram BASremote Devices Power Input Connection 21 Appendix C: Wiring Diagram Master Device to Expansion (Slave Connection) 22 Appendix D: Wiring Diagram Master Alarm Computer Interface Module to BASremote Master Device 23 Appendix E: Wiring Diagram Dry-Contacts Signals Inputs 24 At factory shipment vs after installed and connected at facility 24 Appendix F: Wiring Diagram BASremote Master Devices with Cat-5 Cables 25 Appendix G: Technical Specifications 26 Cable Requirement 26 Contact Info

4 User Responsibility The information contained in this Installation and Operation Guide pertains only to the BACnet Alarm. This product will perform to conformity as described in this guide when assembled, operated, maintained and serviced in accordance with the installation instructions provided. The BACnet Alarm MUST be checked periodically. Parts that are broken, missing, worn, distorted or contaminated must be replaced immediately. Should such repair or replacement become necessary, please contact Amico Corporation or their distributors. The BACnet alarm should not be repaired or altered without prior written or verbal approval of Amico Corporation or its distributors. Failure to comply will void all warranty on the alarm. Statements in this manual preceded by the words WARNING, CAUTION and DANGER are of special significance. Please read these sections carefully. WARNING: Denotes steps which can prevent injury. CAUTION: Denotes steps which can prevent damage to equipment. DANGER: Denotes steps which can prevent electrical shock to equipment or prevent serious injury and/or death. 4 Amico Corporation

5 Introduction The BACnet interface system shall be an Amico Alert-1 series. The BACnet Interface Module provides a convenient method of interfacing Amico Master Alarm to building automation systems that utilizes BACnet technology. The BACnet interface complies with BACnet/IP as defined in ANSI/ASHRAE Standard It is composed of a 3rd party BACnet devices wired and configured to translate dry-contacts signal from Amico Master Alarm panel to a BACnet/IP format which can be access with any BACnet/IP server. The BACnet system can handle up to 30 master alarm points, each master circuit board needs a computer interface to communicate from the Master to BACnet device. FEATURES INCLUDE: NOTE: Network accessible I/O with built-in 10/100 Mbps Ethernet port Supports BACnet/IP Adheres to BACnet Application Specific Controller (B-ASC) profile Supports up to 30 Master Alarm inputs Low-voltage 24 VAC or VDC powered LED indicators for inputs, outputs, CPU status, and Ethernet activity/link/data rate If more information is required about this BASremote Device, the Contemporary Control installation guide, BASremote user manual and data sheet will be provided. The Contemporary Control web Link: Description of BACnet Alarm SHIPMENT DETAILS When you receive the BACnet alarm from Amico Corporation, the package will consist of two main sections; the BACnet Alarm Back Box and the Frame Assembly. The BACnet back box assembly will be pre-configured, with the appropriate modules, based upon the customer s specifications. THE BACNET ALARM BACK BOX The BACnet Alarm Back Box contains the auto-switchable System Power Supply with an ON/OFF switch, a built-in fuse and terminal block (115 VAC, or 220 VAC). This design will reduce installation time and eliminate the risk of improper installation since all the modules are connected and tested at the factory THE FRAME ASSEMBLY The Frame Assembly consists of the BACnet frame with screws to mount. 5

6 Description of Modules SYSTEM POWER SUPPLY AC Supply 115 to 220 VAC Fuse (1 AMPw) G N L L - Live N - Neutral G - Ground Ground Toggle Switch The System Power Supply has been pre-installed into the back box assembly. The System Power Supply converts the AC voltage supply to the alarm into DC voltages: 24 VDC (regulated) required by BACnet Device. This unit also contains the main ON/OFF power switch, the transformer, the heat sink, the main fuse and fuse holder. The System Power Supply can be easily removed and reinstalled by unscrewing it from the back box. DC Power Cable: Connect to Annunciator Module BASREMOTE MASTER DEVICE The BASremote Master provides the ultimate in flexibility. It can be used for expansion I/O at remote locations where an Ethernet connection exists. Its built-in router and gateway capabilities address unique integration needs where more than one communications protocol is involved. It can operate as BACnet/IP and Modbus TCP remote I/O, Sedona Framework controller, Modbus Serial to Modbus TCP router, Modbus Serial to BACnet gateway, and Modbus master to attach Modbus slaves all at the same time. A 10/100 Mbps Ethernet port allows connection to IP networks and popular building automation protocols such as Modbus TCP, BACnet/IP, and Sedona SOX. Six universal I/O points can be configured through resident web pages using a standard web browser and without the need of a special programming tool, your IT department can easily interact with the BASremote Master. BASREMOTE EXPANSION DEVICE The BASremote Expansion devices can communicate with Master device, up to 3 Expansion devices can be connected with Master Device. Each device has up to six universal I/O points. It s an additional universal I/O can be achieved with the simple addition of BASremote Expansion modules. The BASremote PoE has the same capabilities as the BASremote Master except it is powered over the Ethernet connection thereby providing a "One Cable Solution". 6 Amico Corporation

7 Installation BACNET ALARM BOX Static Electricity, Discharge body static before opening/installing the device The Amico BACnet is shipped in one container holding two separate packages. One package contains the BACnet. The other package contains the window and the frame assembly. Install the BACnet back-box to the studs of the wall at the desired height. Ensure that the box is securely in place. The mounting brackets are adjustable to suit the thickness of the wall. MAKE SURE the box is squared and flush with the finished wall surface, to ensure that the frame assembly will fit properly. The recommended mounting is 66" (1676 mm) from the top of the BACnet box to the finished floor. NOTE: The Power Supply, BASremote Master and BASremote Expansion devices are pre-tested and mounted inside the BACnet alarm box. 7

8 Wiring SYSTEM POWER SUPPLY TURN OFF THE POWER SWITCH BEFORE CHANGING ANY MODULES AND/OR DISCONNECTING ANY CABLES, OR ELSE THE FUSE WILL BLOW TO PROTECT THE CIRCUITRY. 1. Ensure that the ON/OFF switch is in the OFF position. 2. Through the top left side of the back box, bring in the AC power wires. Knockouts are provided for making conduit connections to the box. All wiring is to be installed according to local and national codes. 3. Connect the AC power to the terminal blocks as shown in the wiring diagram in Appendix A and as specified in the technical specification. 4. To protect from static electricity, ensure to discharge body static before installing the BACnet Device and connecting Source Equipment signal wires BASREMOTE MASTER/EXPANSION DEVICE Low Voltages Wires: 1. Pull the dry-contact signal wires from computer interface module into the BASremote Master/Expansion device s terminals. Make the connections to the terminal blocks located on the side of the module as labeled. The wiring is fail-safe normally closed (NC) connections from the source equipment. The signal level is 5 VDC. 2. Make the appropriate wiring connections as per Appendix D & E. 3. These devices should be connected with a #22 gauge standard wires from sources or Master alarm Computer interface module. Make sure the polarity (+ & -) on each channel. CAT-5 Cable: The 2 CAT-5 cables can be connected from each BASremote Master Device to a PC, laptop, or server to monitor by BMS or any similar system. Please refer to wiring Appendix F. Note: To turn ON power and make sure all LEDs are devices are powered up and flashed. Status: During boot-up, this LED flashes green. Once all files are loaded, it glows solid green to indicate the unit is operational. Ethernet: This LED glows if a valid link exists to an operating Ethernet device. It indicates speed by colour green for 100 Mbps and yellow for 10 Mbps. I/O: Each of these LEDs glows green when the associated I/O point is in alarm condition (ON) and normal condition LED will be clear (OFF). 8 Amico Corporation

9 Configuration SYSTEM CONFIGURATION Before the BACnet connects to BMS server system. It is recommended to test with laptop or PC to make sure all contacts work. To test this BACnet device, Java software should be installed before it disconnects from Internet. Download the Java program base on your operating system for initial setup ( recommends Windows 10). Once the Java program is downloaded, make sure to disconnect internet connection. NOTE: The PC should be temporarily disconnected from the Ethernet/LAN in case the master s default address matches that of a device on the existing LAN. The procedure for altering the IP address creates a temporary LAN composed of nothing but the master, the PC used to configure it with a CAT5 cable connecting the two. To Change IP & Subnet Addresses: Control Panel > Network and Sharing System > Ethernet / LAN > Properties > Internet Protocol Version 4 (TCP/IPV4) > Select Use the following IP address > IP address: and Subnet Mask:

10 Configuration To Ping BASremote Master Devices from Laptop/PC: After Network Setup is completed, connect both BASremote Master devices one by one into laptop/pc to make sure communication between laptop/pc and BACnet from Command Prompt. CAT-5 Cable Laptop BASremote Master Device Go to Search Bar > type CMD > select Command Prompt > type PING > Enter When Ping is replied from IP Address, make sure the Ping statistics shows at the Command Prompt. 10 Amico Corporation

11 Configuration WEB CONFIGURATION BASREMOTE Open the Internet Browser and type in (Default BASremote Master Device IP address) on the address bar and hit Enter. Authentication: If prompted for a user ID and password when accessing the BASremote webpage, type in: User name: admin & Password: admin Java System Software will popup automatically and ask to login, type in: User name: admin & Password: admin A security warning window will pop up, please click on I accept the risk and want to run this application and click Run (It is recommended to get an approval with your IT administrator)

12 Configuration CONFIGURE SETTINGS BASremote Web Configuration page will be appear with Remote Configuration and Current Settings. As current settings, the dry-contact channel LED bar will display the present value in green LED (On/Off) Individual Channel Settings Configure Settings Channel 1-6 LED Status Channel Names 1-6 If you need to make any changes on System Name, IP Address, Subnet Mask, Gateway Address, Expansion Units, Device Instance, etc., you have to click on Configure Settings and save it for UPDATE. If any changes are made, make sure to reset BACnet power (turn-off) and close all BASremote Configuration Web pages from Laptop/PC; otherwise the memory won t reset. When you restart the system, all changes or modification will register into the BACnet memory and save all info. 12 Amico Corporation

13 Configuration RESET IP ADDRESS ON BASREMOTE MASTER DEVICE To reset the Master module to its default values of the IP address ( ), Gateway address ( ) and Subnet Mask ( ), use a paperclip or similar tool to press the reset switch while the unit is repowered and until the reboot is complete. Once the Status LED stops flashing, release the reset switch. The unit will now use the default values. Reset IP 13

14 Configuration CHANNEL TYPE CHANGE & SAVE: CHANNEL NAME, BASREMOTE UNIT GROUP / VALUE / DESCRIPTION , Text Message & Login User Name and Password (Option) 14 Amico Corporation

15 Configuration If there is any fault signal on BACnet device, it will automatically send an or text message to Admin. You can create your own address or Text message. Creating or Changing Username & Password For security reason, you can create your own Username & Password. When the setup is completed, the BASremote Master Devices can connect directly to BMS or to any similar server systems. It is recommended that an IT qualified technician should handle future setup or modification. NOTE: If more information is required about the BASremote Devices, Contemporary Control Installation Guide, BASremote User Manual and Data Sheet will be provided with each BACnet Device for more details. Here is the Contemporary Control web link:

16 Dimensions A2P-BACNET-30 12" [ " mm] 24" [609.6 mm] 24" Height 24" Width 12" Depth 3.88" Weight 15 lb NOTE: It is recommended to install the Master Alarm and the BACnet Device closer to each other. To protect from static electricity, ensure to discharge body static before installing the BACnet Device and connecting Source Equipment signal wires. SPARE PART NUMBERS DESCRIPTION BAS Remote Master 6PTS Universal I/O BAS Remote Expansion 6PTS Universal I/O BACNET Power Supply Module 24VDC Alarm BACNET Device Window Computer Interface MOD. English 10-PTS MODEL NUMBER A2P-BACNET-6M A2P-BACNET-6X A2P-POWER-BACNET A2X-BAC-WIN-U5 A2P-COMP Amico Corporation

17 Diagram A BASREMOTE MASTER DEVICE Dry-Contact Inputs 0-10 VDC Each device can handle up to 6 signals CH 1-3 DO NOT REMOVE CH 4-6 Default IP Address /69 LEDs - Staus/Ethernet Ethernet CAT-5 Cable Port 10/100 Mbps Ethernet with auto-negotiation and auto -MDIX. Protocols supported include HTTP, IP, UDP TCP, SOAP, BACnet/ IP, Modbus TCP and Sedona SOX. Power Input 24 VDC Expansion Port Proprietary bus supporting up to three expansion modules requiring no configuration. CH from 1-6 Input signals LED status NOTE: The units are tested and basic cables are connected on each devices for standard setting. Do not disconnect wires or remove terminals from each devices. Do not open or modify the device, warranty will be voided. If any wires are removed at the site, make sure to connect all wires properly. Otherwise it can cause damage to the BACnet devices. 17

18 Diagram B BASREMOTE EXPANSION DEVICE Dry-Contact Inputs 0-10 VDC Each device can handle up to 6 signals CH 1-3 CH 4-6 DO NOT REMOVE LEDs - Staus/Network Power Input 24 VDC Expansion Port Proprietary bus supporting up to three expansion modules requiring no configuration. CH from 1-6 Input signals LED status NOTE: The units are tested and basic cables are connected on each devices for standard setting. Do not disconnect wire or remove terminals from each devices. Do not open or modify the device, warranty will be voided. If any wires are removed at the site, make sure to connect all wires properly. Otherwise it can cause damage to the BACnet devices. 18 Amico Corporation

19 Diagram C COMPLETE BACNET BASremote Expansion Devices Master Device to Expansion Slave Connection (Pre-wired) ON/OFF Toggle Switch Ground Wire AC Supply Input 115 to 220 VAC Terminal Power Supply A2P-POWER-BACnet Fuse Holder An Extra 1 Amp Fuse DC Connector 24 VDC Input Connections (Pre-wired) BASremote Master Devices Input Signals Labeling Location Input Channels from Source Equipment or Master Alarm: 1 to 30 Inputs (Do not throw terminals) Input Signals LED Status Status & Network LEDs Master Devices IP Address Status & Ethernet LEDs CAT-5 Cable Connections Master Devices Instance # 19

20 Appendix A WIRING DIAGRAM AUTO-SWITCH POWER SUPPLY AC Supply 115 to 220 VAC 115 to 220 VAC G N L L - L - Live N - N - G Neutral - Ground G - Ground Fuse holder (1 AMPw) Fuse (1 AMPw) ON/OFF Toggle Switch Toggle Switch Ground DC Power Cable: Connect to Annunciator Module Ground (Black) DC Power Cable: Connect to Annunciator Module 24 VDC (Orange) CAUTION: 1. Verify that power has been switched off prior to working on the alarm 2. Risk of electric shock, disconnect power at the circuit breaker before removing the power supply shield 20 Amico Corporation

21 Appendix B WIRING DIAGRAM BASREMOTE DEVICES POWER INPUT CONNECTION Expansion - 1 Expansion - 2 Expansion - 3 G AC Supply 115 to 220 VAC N 115 to 220 VAC L L - L - Live N - N - G Neutral - Ground G - Ground Fuse holder Fuse (1 AMPw) (1 AMPw) Ground ON/OFF Toggle Switch Toggle Switch COM - Ground HI - 24 VDC DC power Cable: Connect to Annunciator Module Master - 1 Master - 1 DC Power Cable: Ground Connect to Annunciator Module (Black) 24 VDC (Orange) COM - Ground HI - 24 VDC CAUTION: 1. Verify that power has been switched off prior to working on the alarm 2. Risk of electric shock, disconnect power at the circuit breaker before removing the power supply shield NOTE: The units are tested and basic cables are connected on each devices for standard setting. Do not disconnect wire or remove terminals from each devices. Do not open or modify the device, warranty will be voided. If any wires are removed at the site, make sure to connect all wires properly. Otherwise it can cause damage to the BACnet devices. 21

22 Appendix C WIRING DIAGRAM MASTER DEVICE TO EXPANSION (SLAVE CONNECTION) Expansion - 1 Expansion - 2 Expansion - 3 D + D + D - D - Master - 1 Master - 2 D + D - NOTES: Each BASremote Master Device can handle up to 3 BASremote Expansion Devices. These Devices are pre-wired and tested from factory. Do not remove wires or terminals, unless its is needed for a signal connection or for replacement only. The units are tested and basic cables are connected on each devices for standard setting. Do not disconnect wires or remove terminals from each devices. Do not open or modify the device, warranty will be voided. If any wires are removed at the site, make sure to connect all wires properly. Otherwise it can cause damage to the BACnet devices. 22 Amico Corporation

23 Appendix D WIRING DIAGRAM MASTER ALARM COMPUTER INTERFACE MODULE TO BASREMOTE MASTER DEVICE Computer Interface Module Module Source Equipment Dry contacts for interface with: Dry Building contacts Management for interface with: Building Management System. System Contacts or are BACnet Commondevices contacts and NC, open are on common Alarm. and NC, open on Alarm. Ratings: 24VDC 0.1A Ratings: 24VDC 0.1A CH01 CH02 CH #22 Gauge Stranded Wires Master Master Module Module SW-2 To Master Alarm Computer Inerface Module CH01 to CH03 To Master Alarm Computer Inerface Module CH04 to CH06 CH "+" N/C, N/O CH "-" Common, Ground CH01 CH02 CH03 Master CH04 CH05 CH06 NOTES: Each Device can handle up to 6 channel Inputs Use minimum #22 gauge stranded wire (does not have to be shielded or twisted pair) 23

24 Appendix E WIRING DIAGRAM DRY-CONTACTS SIGNALS INPUTS To Master Alarm Computer Inerface Module CH07 to CH09 To Master Alarm Computer Inerface Module CH10 to CH12 To Master Alarm Computer Inerface Module CH13 to CH15 To Master Alarm Computer Inerface Module CH16 to CH18 To Master Alarm Computer Inerface Module CH19 to CH21 To Master Alarm Computer Inerface Module CH22 to CH CH07 CH08 CH09 Expansion Expansion Expansion - 3 CH10 CH11 CH12 CH13 CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH CH22 CH23 CH24 #22 Gauge Stranded Wires To Master Alarm Computer Inerface Module CH01 to CH CH01 CH02 CH03 To Master Alarm Computer Inerface Module CH04 to CH06 Master Master - 2 CH04 CH05 CH06 To Master Alarm Computer Inerface Module CH25 to CH27 CH25 CH26 CH27 To Master Alarm Computer Inerface Module CH28 to CH CH28 CH29 CH30 AT FACTORY SHIPMENT VS AFTER INSTALLED AND CONNECTED AT FACILITY BACnet ship from factory BACnet installed at facility Note: Basic wires are connected and tested with each device (ship all input terminal to connect signals) Note: After installed, all dry-contact wires and CAT-5 cables are connect at the field 24 Amico Corporation

25 Appendix F WIRING DIAGRAM BASREMOTE MASTER DEVICES WITH CAT-5 CABLES Expansion - 1 Expansion - 2 Expansion - 3 Master - 1 Master - 2 Ethernet Port 1 CAT-5 Cable Ethernet Port 1 CAT-5 Cable 2 Network CAT-5 Cables to connect to server 25

26 Appendix G TECHNICAL SPECIFICATIONS Supply Voltage: Output Voltage: Current Draw: Fuse (1/4 * 1-1/4): VAC, Hz 24 VDC 1 Amp. Max. Fast Blow 1 Amp CABLE REQUIREMENT: Source Equipment to BACnet Device: Cable: Minimum #22 gauge stranded wire (does not have to be shielded, twisted pair) Signal: 5 VDC - < 5 µa NOTE: For Master Alarm, source equipment signal wires must be connected to normally-closed dry contacts. No electrical voltage can be present and contacts must be closed during normal equipment operation. When contacts are open; an alarm condition will be activated. No solid wire should be used for connecting BACnet device. To protect from static electricity, ensure to discharge body static before installing the BACnet device and connecting Source Equipment signal wires. CONTACT INFO: Amico Corporation - Alarm Technical Department Toll Free Tel: Ext Direct: adepartment@amico.com Contemporary Control Systems, Inc. - Technical Support Specialist Tel: Ext. 113 Direct: dmateo@ccontrols.com 26 Amico Corporation

27

28 Amico Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada 71 East Industry Court, Deer Park, NY 11729, USA Toll Free Tel: Tel: Fax: APE-OPER-BACNET-ALRM

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BACnet Communication Card RXRX-AY01 RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED

More information

BAS Router BACnet Multi-Network Router

BAS Router BACnet Multi-Network Router BAS Router BACnet Multi-Network Router The BAS Router provides stand-alone routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and BACnet MS/TP thereby allowing the system integrator to

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

SHEET. BAS Portable Router BACnet Multi-Network Router. BAS Portable Router

SHEET. BAS Portable Router BACnet Multi-Network Router. BAS Portable Router BAS Portable Router d a t a SHEET BAS Portable Router BACnet Multi-Network Router The BAS Portable Router provides stand-alone routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and BACnet

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

ETH044-4 SSR (230VAC) and 4 Digital IO

ETH044-4 SSR (230VAC) and 4 Digital IO ETH044-4 SSR (230VAC) and 4 Digital IO Technical Documentation WARNING Mains Voltages can be Lethal. If you are not confident with using these voltages, please use a qualified electrician to wire this

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

TIME SERVER NETSILON. Quick start.

TIME SERVER NETSILON. Quick start. TIME SERVER NETSILON Quick start This document refers to the following products: 907,900 NETSILON 7 (100-240 VAC) 907,901 NETSILON 7 (18-36 VDC) 907,902 NETSILON 7 (100-240 VAC + 18-36 VDC) www.bodet-time.com

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.

More information

BACnet /IP to MS/TP Adapter User Guide

BACnet /IP to MS/TP Adapter User Guide BACnet /IP to MS/TP Adapter User Guide Document Revision History: Version 1.0 - Initial Release February, 2010 BACnet/IP to MS/TP Adapter - User Guide 1.0 05DI-UGBRTPB-10 Copyright Distech Controls Inc.

More information

Innovative Electronics for a changing world MANUAL POE 4+4 GM

Innovative Electronics for a changing world MANUAL POE 4+4 GM Innovative Electronics for a changing world MANUAL POE 4+4 GM Index: Description Technical and connections Screen shots Physical Description: The POE 4 +4 GM is an 4+4 = 8 Channel Gigabit DC passive power

More information

GUIDE. EIPR Skorpion IP Router EIPR

GUIDE. EIPR Skorpion IP Router EIPR a p p l i c a t i o n GUIDE EIPR EIPR Skorpion IP Router The EIPR links two Internet Protocol (IPv4) networks together passing appropriate traffic while blocking all other traffic. One of the networks

More information

BACnet/IP to BACnet MS/TP Router

BACnet/IP to BACnet MS/TP Router BACnet/IP to BACnet MS/TP Router Features Compact Size Routes between BACnet /IP and BACnet MS/TP networks 10/100Mbps Ethernet Auto-MDIX port Optically isolated MS/TP communications port MS/TP baud rates:

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information

SEM3 - Embedded Micro Metering Module

SEM3 - Embedded Micro Metering Module SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or

More information

MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication Module

MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication Module Installation and Maintenance Manual IM 916-2 Group: Controls Part Number: IM 916 Date: October 2009 Supercedes: IM 916-1 MicroTech III Rooftop and Self Contained Unit Controller BACnet IP Communication

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Installation and Operation Manual. Model ER8500U / ER16500U. Patent Pending. Head-end Installation ER8500U and ER16500U. Rack Mounting Options

Installation and Operation Manual. Model ER8500U / ER16500U. Patent Pending. Head-end Installation ER8500U and ER16500U. Rack Mounting Options USA EUROPE Model ER8500U / ER16500U Installation and Operation Manual Reduce risk of fire or electrical shock. Do not expose this product to rain or moisture. Note: This installation should be made by

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

Innovative Electronics for a changing world MANUAL. POE 4 GM PCB only

Innovative Electronics for a changing world MANUAL. POE 4 GM PCB only Innovative Electronics for a changing world MANUAL POE 4 GM PCB only Index: Description Technical and connections Screen shots Physical Description: The POE 4 GM is an 4 Channel Gigabit DC passive power

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Contents Summary... 3 Introduction... 5 User-define Terminal Parameters... 6 Fault Exclude... 14

Contents Summary... 3 Introduction... 5 User-define Terminal Parameters... 6 Fault Exclude... 14 Contents Summary... 3 Safety Precaution... 3 Product Introduction... 4 Interface Description... 4 Introduction... 5 Packing List... 5 Wiring... 5 User-define Terminal Parameters... 6 Login Webpage... 6

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet or IP Installation and Maintenance Manual IM 853 Group: Controls Part Number: IM 853 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module, Ethernet

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

BASview2 a simple web-based graphical interface

BASview2 a simple web-based graphical interface BASview2 a simple web-based graphical interface BASview2 is a stand-alone, embedded, web-based graphical interface for building automation and process automation systems. It can be accessed from any web

More information

Portable BASrouter BACnet Multi-Network Router

Portable BASrouter BACnet Multi-Network Router Portable BASrouter BACnet Multi-Network Router The Portable BASrouter is a compact BACnet multi-network router which provides versatile standalone routing between BACnet/IP, BACnet Ethernet (ISO 8802-3),

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

User Manual Revision English

User Manual Revision English Document code: MN67815_ENG Revision 1.002 Pagina 1 di 23 User Manual Revision 1.002 English Modbus TCP Slave / KNX - Converter (Order Code: HD67815-KNX-B2) for Website information: www.adfweb.com?product=hd67815

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Startup Guide. NetAXS-123. Version 5.2

Startup Guide. NetAXS-123. Version 5.2 NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Installation and Maintenance Manual IM 963 Group: Controls Part Number: IM 963 Date: April 2010 Supercedes: New Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet) Daikin

More information

1. General Description

1. General Description ipio-2, ipio-8, ipio-16 Monitor and Control of Digital I/O 1. General Description The ipio is a network attached, web enabled digital input and output device. The ipio can be controlled and monitored with

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

Installing and Managing the Switch

Installing and Managing the Switch CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4

More information

CAUTION READ CAREFULLY

CAUTION READ CAREFULLY Docking Drawer Install Manual for DD 21 + 24 Slim Applicable Models: 0290-00030, 0290-00030W, 0290 00031, 0290 00031W 0230-00004. r5 10/21/2015 CAUTION READ CAREFULLY Failure to follow these instructions

More information

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

User Manual Revision English

User Manual Revision English Document code: MN67591_ENG Revision 1.001 Pagina 1 di 22 User Manual Revision 1.001 English Ethernet/IP / Modbus Master - Converter (Order Code: HD67591-232-A1, HD67591-485-A1) for Website information:

More information

Installation Instructions

Installation Instructions Infinityt Series WiFi (Wireless) Broadband Remote Access Module Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 SAFETY

More information

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending ILF-100WD User Manual Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending Rev. 1.17 02/24/2009 Table of Contents Installation and Configuration...3 Network Configuration...4

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

Quick Start Guide. NP290W Turbo Wireless HomePlug

Quick Start Guide. NP290W Turbo Wireless HomePlug Quick Start Guide Turbo Wireless HomePlug Contents Chapter 1 Introduction... 3 1.1 Minimum Requirements... 3 1.2 Typical Turbo Wireless HomePlug Connection... 3 1.3 Package Contents... 3 Chapter 2 Turbo

More information

UR51 Industrial Cellular Router

UR51 Industrial Cellular Router UR51 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR51 industrial cellular router. This guide describes how to install the UR51 and

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Quick Start Guide V5.0

Quick Start Guide V5.0 Quick Start Guide V5.0 IDair, LLC Per the Unites States Government Code of Federal Regulations Title 47, Chapter I, Federal Communications Commission (FCC), this device complies with Subchapter A, Section

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax: Description of options TCP/IP Ethernet module user s manual DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189320029B Legal information

More information

Pythia Technologies Inc MS0-BR. BACnet MSTP to BACnet IP Router

Pythia Technologies Inc MS0-BR. BACnet MSTP to BACnet IP Router MS0-BR BACnet MSTP to BACnet IP Router 1 Table of Contents CHANGE HISTORY... 3 1. INTRODUCTION... 4 2. SPECIFICATIONS... 5 3. CONNECTORS... 6 4. POWER... 6 4.1 POWER SUPPLY PRECAUTIONS... 7 4.2 LIMITED

More information

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English BN interface Model name: BMS-IFBN640TLUL English Contents Precautions for safety.................................................... 3 Introduction.............................................................

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers DECK All-In-One Enclosure Quick Installation Guide for Field Installers 1 Contents Legal Statement... 2 Preliminary Considerations... 2 Required Installation Tools and Materials... 2 Networking Information...

More information

SR-201 Network Relay Quick Start Guide

SR-201 Network Relay Quick Start Guide SR-201 Network Relay Quick Start Guide Table of Content Connect to your device...2 Change configurations...3 Setup remote control via internet...4 Android software...5 Integrate to your applications...6

More information

hdpv.org Ampt Communications Unit Installation Manual D

hdpv.org Ampt Communications Unit Installation Manual D hdpv.org Ampt Communications Unit Installation Manual 57070008-1 D 2 Copyright 2016-2019 Ampt LLC. All rights reserved. No part of this document may be reproduced, retransmitted, or copied in any form

More information

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX BASgatewayLX d a t a SHEET BASgatewayLX Modbus to BACnet Gateway Modbus remains a popular network interface. It is commonly found on jobs such as boiler control, variable speed drives, and metering applications,

More information

UPS READY POWER DISTRIBUTION ASSEMBLY

UPS READY POWER DISTRIBUTION ASSEMBLY UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of

More information

Solis Single Phase Inverter

Solis Single Phase Inverter PV Grid Tie Inverter Solis Single Phase Inverter Installation and Operation Manual Ningbo Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712,

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

1 Introduction Purpose of this Manual General Specifications Access Levels and Passwords Access and Passwords Addresses...

1 Introduction Purpose of this Manual General Specifications Access Levels and Passwords Access and Passwords Addresses... Installation Manual 5100 Series, Catalog 5140 Quad-Ethernet Module Accessory 72EE for New Series 300 Transfer Switches, (with Group G controller) & 5210 Digital Power Meter Section 1 Introduction Purpose

More information

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these

More information

UR72 & UR75 Industrial Cellular Router

UR72 & UR75 Industrial Cellular Router UR72 & UR75 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR72/UR75 industrial cellular router. This guide describes how to install

More information

Acti 9 Communication System

Acti 9 Communication System Acti 9 Communication System Diagnostics User Manual 05/2012 DOCA0042EN-00 www.schneider-electric.com This document contains general descriptions and/or general technical specifications of the products

More information

User Manual Revision English

User Manual Revision English Document code: MN67716_ENG Revision 1.000 Page 1 of 24 User Manual Revision 1.000 English BACnet Master / PROFIBUS Slave - Converter (Order Code: HD67716-IP-A1, HD67716-MSTP-A1, HD67716-PTP-A1) For Website

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH 8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH West Penn Wire 2018 94-000880-A / SE-000880-A Page 1 / 20 Introduction The 8 Button IP Controller (Model: AV-IP-C8-WH) is a versatile

More information

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.0.2

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.0.2 HD Mini IR Waterproof Fixed Network Camera Quick Start Guide Version 1.0.2 Welcome Thank you for purchasing our network camera! This quick start guide is designed to be a reference tool for your system.

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

UniStream HMI Panel. CPU-for-Panel

UniStream HMI Panel. CPU-for-Panel UniStream HMI Panel Installation Guide USP-070-B10,USP-104-B10, USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD.  Address: 34 Main Street, Whitesboro, NY 13492 MODEL 9007/9008 TENNIS SCOREBOARD Instruction Manual Address: 34 Main Street, Whitesboro, NY 13492 Phone: 315-736-3967 Toll Free: 800-383-6060 Fax: 315-736-4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1. SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE Manual No. D4600-7010 Revision Date: 08/2016 Control: 1.0 Microframe Corporation 604 South 12th Street Local: 918-258-4839

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

BASR Versatile BACnet/IP Controller/Gateway. BASremote. User Manual # TD MH. (for firmware version 3.7.x)

BASR Versatile BACnet/IP Controller/Gateway. BASremote. User Manual # TD MH. (for firmware version 3.7.x) BASR Versatile BACnet/IP Controller/Gateway BASremote User Manual # (for firmware version 3.7.x) Trademarks Contemporary Controls and CTRLink are registered trademarks of Contemporary Control Systems,

More information

Chore-Tronics Mobile Server

Chore-Tronics Mobile Server Chore-Tronics Mobile Server Installation & Operator s Instruction Manual Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Group A division of

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information