CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Size: px
Start display at page:

Download "CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual"

Transcription

1 550 Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: Kanata, Ontario Facsimile: KK A9 Technical Support: Canada -CONTROL

2 550 Analog Input Hardware Manual Control Microsystems Inc. All rights reserved. Printed in Canada. Trademarks TeleSAFE, TelePACE, SmartWIRE, SCADAPack, TeleSAFE Micro6 and TeleBUS are registered trademarks of Control Microsystems Inc. All other product names are copyright and registered trademarks or trade names of their respective owners. Material used in the User and Reference manual section titled SCADAServer OLE Automation Reference is distributed under license from the OPC Foundation. 550 Analog Input Hardware Manual October 9, 007

3 Table of Contents OVERVIEW... 3 IMPORTANT SAFETY INFORMATION... 3 INSTALLATION Field Wiring Address Selection Input Offset Selection... OPERATION AND MAINTENANCE Data Format % Input Offset % Input Offset Maintenance Troubleshooting Calibration SPECIFICATIONS... 6 APPROVALS AND CERTIFICATIONS... 3 Index of Figures Figure : 550 Typical 0mA Field Wiring... 6 Figure : 550 Typical 5 Volt Field Wiring... 6 Figure 3: 550 Analog Input Address Switches... 7 Figure : 550 Input Offset Switches Analog Input Hardware Manual October 9, 007

4 Overview The model 550 analog input module adds eight analog inputs to the 5000 Series input/output system. Up to sixteen model 550 modules may be connected to the I/O bus, for a total of analog inputs per I/O bus. These inputs are used with devices such as pressure, level, flow, and temperature transmitters; instrumentation such as ph and conductivity sensors; and other high-level analog signal sources. The 550 module is configured for either 0mA current loop or 5 volt operation. The current loop has 50 ohm current sense resistors on the inputs. It is otherwise identical to the voltage module. DIP switches enable or disable a 0% input offset. The module measures 0 to 0mA or 0 to 5 V signals with the offset disabled. The module measures to 0mA or to 5 V signals with the offset enabled. The 550 module uses a bit successive approximation analog to digital (A/D) converter. A single chip microcontroller with integral watchdog timer operates the A/D and communicates over the I/O bus. All inputs are transient protected and optically isolated from the main logic power. The inputs are single ended. They share a common return. 550 Analog Input Hardware Manual October 9, 007 3

5 Important Safety Information Power, input and output (i/o) wiring must be in accordance with Class I, Division wiring methods Article 50- (b) of the National Electrical Code, NFPA 70 for installations in the U.S., or as specified in Section -J of the Canadian Electrical Code for installations within Canada and in accordance with the authority having jurisdiction. WARNING! EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS, DIVISION. WARNING! EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. WARNING! EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. 550 Analog Input Hardware Manual October 9, 007

6 3 Installation The installation of the 550 module requires mounting the module on the 7.5mm by 35mm DIN rail and connecting the module to the system I/O Bus. Refer to the System Configuration Guide, at the beginning of this manual, for complete information on system layout, I/O Bus cable routing and module installation. 3. Field Wiring The 550 module provides eight single ended analog inputs. All inputs share a common return (SIG COM). Controller, modem and I/O modules use screw termination style connectors for termination of field wiring. They accommodate solid or stranded wires from to AWG. The connectors are removable. This allows module replacement without disturbing the field wiring. Leave enough slack in the wiring for the connector to be removed. CAUTION: To remove the connector: Remove power before servicing unit. Pull the connector upward from the board. Apply even pressure to both ends of the connector. To install the connector: Line up the pins on the module with the holes in the connector. Make sure all the pins line up properly. Push the connector onto the pins. Apply even pressure to both ends on the connector. Connect an external -30V DC power supply to the Power Input terminals. This is to power the isolated analog input circuits. 5V power required for the digital circuitry is available on the I C bus. Refer to the specifications for details. The 0mA version supports loop powered and self-powered transmitters. Loop powered transmitters connect between the + volts and the analog input. The loop current continues to the volt return through a 50 ohm resistor built into the 0mA input circuit. Self-powered transmitters connect to the analog input and to SIG COM. Figure : 550 Typical 0mA Field Wiring shows how to wire these transmitters. 550 Analog Input Hardware Manual October 9, 007 5

7 Volt Input + SIG 0 3 COM SIG COM Current Sense Resistors + + V Supply + + V Supply wire loop powered transmitter shown on Input Self powered transmitter shown on Input 6 Figure : 550 Typical 0mA Field Wiring The 5 volt version is identical to the 0mA version except that the 50 ohm input resistors are not installed. 5 volt signals connect from the analog input to SIG COM. Figure : 550 Typical 5 Volt Field Wiring shows how to wire 5 volt inputs. Volt Input + SIG 0 3 COM SIG COM + V Supply 5 Volt transmitter shown on Input 6 + Figure : 550 Typical 5 Volt Field Wiring 550 Analog Input Hardware Manual October 9, 007 6

8 3. Address Selection The 5000 Series I/O bus will support a maximum of forty I/O (input/output) modules Series I/O module types may be combined in any manner to the maximum supported by the controller used. The types of input and output modules available are: Digital Input modules Digital Output modules Analog Input modules Analog Output modules Counter Input modules Each type of I/O module, connected to the I/O bus, must have a unique I/O module address. Different types of I/O modules may have the same module address. The address range supported by the SmartWIRE, SCADAPack or TeleSAFE Micro6 controller module may restrict the I/O module address range. Refer to the controller manual for the maximum address supported. Four address switches labeled,, and set the module address. To set the address: Open all four switches by pressing down the left side of the switch. Close the switches that total to the desired address. Figure 3: 550 Analog Input Address Switches shows the switch setting for each of the 6 module addresses How to Set Switches Determine the module address. Press the side of the switches shown in gray above. Press this side to ignore switch value Press this side to add switch value Figure 3: 550 Analog Input Address Switches 550 Analog Input Hardware Manual October 9, 007 7

9 3.3 Input Offset Selection The 550 module can apply 0% input offset to the signals measured. With the offset enabled, the module reads -0mA signals or -5 V signals. With the offset disabled the module reads 0-0mA signals or 0-5 V signals. To enable the 0% offset: Open the two switches labeled 0% by pressing down the left side of the switches. Close the two switches labeled 0% by pressing down the right side of the switches. To disable the 0% offset (and select 0% offset): Open the two switches labeled 0% by pressing down the left side of the switches. Close the two switches labeled 0% by pressing down the right side of the switches. Figure : 550 Input Offset Switches shows the switch settings for enabling and disabling the offset. 0% Input Offset 0% Input Offset How to Set Offset Switches Determine the desired offset Press the side of the switches shown in gray. 0% Offset 0% Offset 0% Offset 0% Offset Press this side to disable switch function Press this side to enable switch function Figure : 550 Input Offset Switches 550 Analog Input Hardware Manual October 9, 007

10 Operation and Maintenance. Data Format 5000 Series analog input and output modules use 6 bit signed numbers (5 bits plus sign). s with less than 6 bit resolution normalize the data into the 6 bit format. The 550 module has a bit, unipolar, analog to digital (A/D) converter. There are 096 A/D counts in the input signal range. The module can be configured to use 0% or 0% input offset. The input resolution is better with the 0% input offset, due to the smaller input range... 0% Input Offset The 0% input offset configuration measures 0-0mA or 0-5V signals. The input resolution is:.ua/count on 0mA version.mv/count on the 5 V version The table below shows the A/D output value for several input signals... 0% Input Offset Current(mA) Voltage(V) A/D Output The 0% input offset configuration measures -0mA or -5V signals. The input resolution is: 3.9uA/count on the 0mA version 0.976mV/count on the 5 V version The table below shows the A/D output value for several input signals. Current(mA) Voltage(V) A/D Output < < Analog Input Hardware Manual October 9, 007 9

11 . Maintenance This module requires no routine maintenance. If the module is not functioning correctly, contact Control Microsystems Technical Support for more information and instructions for returning the module for repair..3 Troubleshooting Problem 0mA inputs always read 0. Reading is at or near 0 for all input signals. Reading is constant. 0mA readings are not accurate. Action Check transmitter power. Check if the input transient suppressers are damaged. Check that the analog input is not forced. Check for a damaged 50 current sense resistor.. Calibration The 550 module is calibrated and burned in at the factory. It does not require periodic calibration. Calibration may be necessary if the module has been repaired as a result of damage. There are three potentiometers for calibration of the analog inputs. The 5V ADJ. potentiometer (R5) adjusts the gain in the 0% offset configuration. The V ADJ. potentiometer (R9) adjusts the gain in the 0% offset configuration. The V ADJ. potentiometer (R9) adjusts the zero in the 0% offset configuration. Adjustment of the zero in the 0% offset configuration is not necessary. Calibration requires that you read the converted value from the module using a communication or SCADA controller module. Refer to the controller module manual for details. To calibrate the module:. Apply input signals to as many channels as possible.. Measure voltage between U, pin 6 and U, pin. Adjust the 5V ADJ. potentiometer for V. 3. Measure voltage between U3, pin and U, pin. Adjust the V ADJ. potentiometer for.000 V.. Measure voltage between U3, pin 7 and U, pin. Adjust the V ADJ. potentiometer for.000 V. 5. Set offset dip-switches to 0%. Close both 0% dip-switches (press down on the right). Open both 0% dip-switches (press down on the left). 6. Apply.99 V (for 5 V version) or 9.993mA (for 0mA version). 7. Read the converted signal from the communication controller. Adjust the 5V ADJ. potentiometer for readings that alternate between 375 and 3760 on all channels.. Set offset dip-switches to 0%. Close both 0% dip-switches (press down on the right). Open both 0% dip-switches (press down on the left). 9. Apply.0005 V (for 5 V versions) or.00ma (for 0mA version). 550 Analog Input Hardware Manual October 9, 007 0

12 0. Read the converted signal from the communication controller. Adjust the V ADJ. potentiometer for readings that alternate between 0 and on all channels.. Apply.995 V (for 5 V versions) or 9.99mA (for 0mA version).. Read the converted signal from the communication controller. Adjust the V ADJ. potentiometer for readings that alternate between 375 and 3760 on all channels. 3. Repeat steps through if necessary. 550 Analog Input Hardware Manual October 9, 007

13 5 Specifications Disclaimer: Control Microsystems reserves the right to change product specifications without notice. For more information visit Input Points Resolution Input Resistance Converter type Accuracy Input Offset Type Normal mode rejection Over-scale Input Capacity (without damage) Isolation Reading Update Time Response Time Power Requirements Terminations Dimensions Mounting Packaging Environment bits 00k nominal for 5V inputs 50 for 0mA inputs Successive approximation +/ 0.% of full scale at 5 o C (77ºF) +/ 0.% of full scale over temperature range DIP switch configurable for 0% offset Single ended 60dB at 50 / 60 Hz. Continuous: 60% over scale sustained input signal. 0.5A maximum current and.v maximum voltage. Transient:.5kV surge withstand capability as per ANSI/IEEE C VAC from the logic power 00ms 0ms typical for 0% to 90% signal change 5V at 0mA to V at 0mA (loop power extra at 0mA maximum per loop) pole, removable terminal block to AWG 5 amp contacts.5 inch (0mm) wide.65 inch (mm) high.75 inch (mm) deep 7.5 x 35 DIN rail Corrosion resistant zinc plated steel with black enamel paint 5% RH to 95% RH, non-condensing 0 o C to 60 o C 0 o F to 0 o F 550 Analog Input Hardware Manual October 9, 007

14 6 Approvals and Certifications Safety Non-Incendive Electrical Equipment for Use in Class I, Division Groups A, B, C and D Hazardous Locations. 550 Analog Input Hardware Manual October 9, 007 3

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual 550 Differential Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS Potentiometer Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Potentiometer Analog Input Module. Hardware Manual 55 Potentiometer Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual 550 Thermocouple Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual 503 and 50 Digital Input Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual 5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

CONTROL MICROSYSTEMS Toggle Switch Digital Input Module. Hardware Manual

CONTROL MICROSYSTEMS Toggle Switch Digital Input Module. Hardware Manual 5 Toggle Switch Digital Input Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 8 Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support:

More information

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual 50 and 50 Digital I/O Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual 506 and 507 Relay Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual 50 High Speed Counter Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual 5601 and 5601A Input/Output (I/O) Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

5502 Differential Analog Input Module

5502 Differential Analog Input Module 550 Differential Analog Input Installation, Operation and Maintenance Setup Manual //07 Copyright 0-07 Schneider Electric Canada Inc. All rights reserved. 550 Differential Analog Input The information

More information

5504 Thermocouple Analog Input Module

5504 Thermocouple Analog Input Module 550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

CONTROL MICROSYSTEMS. SCADAPack Micro 16. Quick Start Guide

CONTROL MICROSYSTEMS. SCADAPack Micro 16. Quick Start Guide SCADAPack Micro 16 Quick Start Guide CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

5403 and 5404 Digital Input Modules

5403 and 5404 Digital Input Modules 503 and 50 Digital Input Modules Installation, Operation and Maintenance Setup Manual //07 Copyright 0-07 Schneider Electric Canada Inc. All rights reserved. 503 and 50 Digital Input Modules The information

More information

CONTROL MICROSYSTEMS Input/Output (I/O) Module. Hardware Manual

CONTROL MICROSYSTEMS Input/Output (I/O) Module. Hardware Manual 5604 Input/Output (I/O) Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical

More information

5401 and 5402 Digital I/O Modules

5401 and 5402 Digital I/O Modules 50 and 50 Digital I/O Modules Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

5521 Potentiometer Analog Input Module

5521 Potentiometer Analog Input Module 55 Potentiometer Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

CONTROL MICROSYSTEMS. SCADAPack 100 Controller. Hardware Manual

CONTROL MICROSYSTEMS. SCADAPack 100 Controller. Hardware Manual SCADAPack 100 Controller Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

SCADAPack E 5405 Digital Input Hardware Manual

SCADAPack E 5405 Digital Input Hardware Manual SCADAPack E 5405 Digital Input Hardware Manual 2 SCADAPack E 5405 Digital Input Hardware Manual Table of Contents Part I 5405 Digital Input Module 3 1 Technical... Support 3 2 Safety... Information 4 3

More information

5607 Input/Output (I/O) Module

5607 Input/Output (I/O) Module 5607 Input/Output (I/O) Module Installation, Operation and Maintenance Setup Manual 5/19/2011 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

CONTROL MICROSYSTEMS. TeleSAFE Micro16 Controller. Hardware Manual

CONTROL MICROSYSTEMS. TeleSAFE Micro16 Controller. Hardware Manual TeleSAFE Micro16 Controller Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

SCADAPack E 5505 RTD Input Hardware Manual

SCADAPack E 5505 RTD Input Hardware Manual SCADAPack E 5505 RTD Input Hardware Manual 2 SCADAPack E 5505 RTD Input Hardware Manual Table of Contents Part I 5505 RTD Input Module 3 1 Technical... Support 3 2 Safety... Information 4 3 Overview...

More information

5601/5601A Input / Output (I/O) Module

5601/5601A Input / Output (I/O) Module 5601/5601A Input / Output (I/O) Module Installation, Operation and Maintenance Setup Manual 5/19/2011 Safety Information The information provided in this documentation contains general descriptions and/or

More information

SCADAPack E I/O Module Hardware Manual (337E Only) Version: Date: August 2017

SCADAPack E I/O Module Hardware Manual (337E Only) Version: Date: August 2017 SCADAPack E 5606 I/O Module Hardware Manual (337E Only) Version: Date: August 2017 Table of Contents 1 Legal...5 Information 2 Technical...6 Support 3 Safety...7 Information 4 Overview...10 5 Installation...11

More information

SCADAPack E 5607 I/O Hardware Manual

SCADAPack E 5607 I/O Hardware Manual SCADAPack E 5607 I/O Hardware Manual 2 SCADAPack E 5607 I/O Hardware Manual Table of Contents Part I 5607 Input/Output Module 3 1 Technical... Support 3 2 Safety... Information 4 3 Overview... 6 4 Installation...

More information

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7 User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7

More information

SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack 350E 357E. Smart Remote Terminal Unit SCADAPack 350E 357E Smart Remote Terminal Unit 1 The SCADAPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12-30 Vdc supply, various communication links and a wide range

More information

SCADAPack Input/Output Module Hardware Manual. Version: February 2016

SCADAPack Input/Output Module Hardware Manual. Version: February 2016 SCADAPack Version: Date: February 2016 Table of Contents 1 Legal Information...6 2 Technical Support...7 3 Safety Information...8 4 Documentation...11 Check 5 About this Manual...13 6 About the 5607 I/O

More information

5604 Input/Output (I/O) Module

5604 Input/Output (I/O) Module 5604 Input/Output (I/O) Module Installation, Operation and Maintenance Setup Manual 5/19/2011 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

5910 Ethernet Gateway Module

5910 Ethernet Gateway Module Hardware Manual 2/24/2017 Copyright 2014-2017 Schneider Electric Canada Inc. All rights reserved. 5910 Ethernet Gateway Module The information provided in this documentation contains general descriptions

More information

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940 May 2015 PACSystems* RX3i and Series 90-30 IC693MDL940 / IC694MDL940 Output Module, Relay, NO, 2 Amp, 16 Point The Series 90*-30 and PACSystems * MDL940 2 Amp Relay Output module provides 16 normally-open

More information

SCADAPack 32. Smart RTU

SCADAPack 32. Smart RTU SCADAPack 32 Smart RTU 1 Compared to the SCADAPack 300 platform, the SCADAPack 32 is a higher performance Smart RTU built to meet the demands of larger applications including support for up to 10 gas flow

More information

EMS467 Monitoring System. Installation and Operations Manual Section 40

EMS467 Monitoring System. Installation and Operations Manual Section 40 EMS467 Monitoring System Installation and Operations Manual 00-02-0672 01-26-10 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V

More information

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 7B31 FEATURES Interfaces, amplifies, and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

CONTROL MICROSYSTEMS. SOLARPack 210. Hardware Manual

CONTROL MICROSYSTEMS. SOLARPack 210. Hardware Manual SOLARPack 210 Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876

More information

SCADAPack 312E 313E 314E

SCADAPack 312E 313E 314E Smart Remote Terminal Units The 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital I/O that

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Process Current Output 7B39 FEATURES Interfaces, isolates and filters a 0 V to + 10 V or +1 V to +5 V input signal. Provides an isolated process current output of 0 ma to 20 ma or 4 ma to 20

More information

SCADAPack 530E 535E. remote Programmable Automation Controller

SCADAPack 530E 535E. remote Programmable Automation Controller SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

SCADAPack Smart RTU

SCADAPack Smart RTU SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated

More information

Isolated Process Current Input with Loop Power 7B35

Isolated Process Current Input with Loop Power 7B35 Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either

More information

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B41 FEATURES Interfaces, amplifies and filters unipolar and bipolar voltage inputs. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V. All 7B41

More information

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223 May 2014 PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223 Analog Current Input Module 16 Channel The PACSystems* RX3i/Series 90* 16-Channel Analog Current Input module provides 16 single-ended

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

SCADAPack E Input/Output Module Hardware Manual. Version: March 2016

SCADAPack E Input/Output Module Hardware Manual. Version: March 2016 SCADAPack E Version: Date: March 2016 Table of Contents 1 Legal Information...5 2 Technical Support...6 3 Safety Information...7 4 About this Manual...11 5 About the 6601 I/O Expansion Module...12 6 Hardware

More information

SCADAPack E Input/Output Module Hardware Manual. Version: March 2016

SCADAPack E Input/Output Module Hardware Manual. Version: March 2016 SCADAPack E Version: Date: March 2016 Table of Contents 1 Legal Information...6 2 Technical Support...7 3 Safety Information...8 4 Documentation...11 Check 5 About this Manual...13 6 About the 5606 I/O

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters INTRODUCTION: Table of Contents Page Introduction 1 Description 1 Specifications 2 Specifications (Display Option) 3 Installation

More information

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack 312E 313E. Smart RTUs for water SCADAPack 312E 313E Smart RTUs for water 1 SCADAPack 312E and 313E Smart RTUs feature 32-bit processing, serial and US communications, integrated 12-30Vdc power supply, advanced power-management and a

More information

Black Box Tech Support: FREE! Live. 24/7.

Black Box Tech Support: FREE! Live. 24/7. Black Box Tech Support: FREE! Live. 24/7. Tech support the way it should be. Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com. About Black Box Black Box Network Services is your

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

SCADAPack E Input/Output Module Hardware Manual. Version: Date: August 2017

SCADAPack E Input/Output Module Hardware Manual. Version: Date: August 2017 SCADAPack E Version: Date: August 2017 Table of Contents 1 Legal Information...5 2 Technical Support...6 3 Safety Information...7 4 Documentation Check...10 5 About this Manual...11 6 About the 5610 I/O

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

PACSystems* RX3i IC694ALG233

PACSystems* RX3i IC694ALG233 November 2015 PACSystems* RX3i IC694ALG233 Advanced Diagnostics Analog Current Input Module 16 Channel The PACSystems* RX3i 16-Channel Analog Current Input module provides 16 single-ended input channels.

More information

TelePACE Studio Ladder Logic Training Manual

TelePACE Studio Ladder Logic Training Manual TelePACE Studio Ladder Logic Training Manual SCADA products... for the distance TelePACE Studio Ladder Editor Training Manual 1999-2009 Control Microsystems Inc. All rights reserved. Printed in Canada.

More information

Actuator Commissioning Tool

Actuator Commissioning Tool Document No. 129-287 Actuator Commissioning Tool Product Description The 985-047 Actuator Commissioning Tool provides a portable instrument for exercising, calibrating, and testing resistive, proportional

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Operation and Maintenance Manual

Operation and Maintenance Manual VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery

More information

SCADAPack 330E 333E 334E 337E

SCADAPack 330E 333E 334E 337E Smart Remote Terminal Units The 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital I/O that

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01 01 Series RoHS Compliant Product Description The Series remote pressure transducers are designed for differential pressure applications. The sensors are remotely installed on existing plumbing runs. The

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1 Stellar Instruments SC1 Controller & Display System General User s Manual Copyright 2013 Stellar Instruments 1 Contents Section 1 General... 3 Section 2 Base Unit A (Multi-Event Programmable Timer)...

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital

More information

Chassis Power Supplies

Chassis Power Supplies PDC24 / PAC Chassis Power Supplies (PDC24 / PAC) Issue 3 October 2005 INTRODUCTION PURPOSE Two Power Supply Units (PSUs) provide a dual-redundant source of 5.4Vand 12Vdc onto the backplane for the modules

More information

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016 Septembery 2016 RSTI-EP Slice I/O EtherCAT Network Adapter Module PWR, BF, MT, L/A IN, L/A OUT, RUN, and ERROR LEDs Ethernet Ports Door for Micro USB Port EtherCAT Network Adapter Power Supply LED The

More information

User's Manual: Series 250T DC Current/Voltage Two-Wire Transmitters

User's Manual: Series 250T DC Current/Voltage Two-Wire Transmitters User's Manual: Series 250T DC Current/Voltage Two-Wire Transmitters Table of Contents Page INTRODUCTION: Introduction... 1 Description... 1 Specifications... 2 Specifications (Display Option)... 3 Installation...

More information

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized RTD Input 5B34 FEATURES Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD measurements are provided by the 5B35).

More information

SCADAPack 100 Controller

SCADAPack 100 Controller Installation, Operation and Maintenance Setup Manual 2/24/2017 Copyright 2014-2017 Schneider Electric Canada Inc. All rights reserved. The information provided in this documentation contains general descriptions

More information

Differential Liquid/Gas Pressure Transmitter

Differential Liquid/Gas Pressure Transmitter Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com Smart Remote Terminal Units The SCDPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

PACSystems* RX3i IC694ALG232

PACSystems* RX3i IC694ALG232 November 2015 PACSystems* RX3i IC694ALG232 Advanced Diagnostics 16 Channel Input Analog Voltage Module The PACSystems* RX3i 16-Channel Analog Voltage Input module provides 16 single-ended or 8 differential

More information

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules DBK48 Multipurpose Isolated Signal-Conditioning Module Description 1 Safety Concerns 2 Hardware Setup 2 Installing 8B Modules 4 Installing Plug-in Resistors to Create 4 to 20 ma Loops 5 Making Terminal

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs Multi-Channel Analog Output Modules DC Current or DC Voltage Outputs Discrete Outputs DI-917MB/DI-918MB Models DI-917MB: 4 current output channels DI-918MB: 4 voltage output channels Analog Output DI-917MB:

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112 SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay

More information

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Magnetic Style Safety Interlock Switches

Magnetic Style Safety Interlock Switches Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment

More information

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions ACTIONI/Q Q498 DC Powered DC Input Field Configurable Isolator with Math Functions Q498-0000 Provides 2 Isolated Analog Inputs, 1 Analog Output & 1 Frequency Output, as well as a Discrete Input & Output

More information

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson.

PCS Ferguson 8000 Series Overview Manual. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. The PCS Ferguson 8000 Series brand is trademarked by PCS Ferguson. These documents and materials are copyrighted by PCS Ferguson. 2016 All rights reserved. For information contact: PCS Ferguson 3771 Eureka

More information

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V Product Information SIMATIC S7-300 Digital Output Module SM 322; DO 16 UC24/48 V X 2 as of Version 3 4 New Digital Output Module Available The S7-300 Digital Output Module SM 322; DO 16 UC24/48 V has been

More information

WARNING 25.2 POWER L.V X1 X2 Y0 C1 Y1 C2 Y2 C3 Y3 ELC-EX NN. 3. Extension unit clip 4. Input/output terminal

WARNING 25.2 POWER L.V X1 X2 Y0 C1 Y1 C2 Y2 C3 Y3 ELC-EX NN. 3. Extension unit clip 4. Input/output terminal POWER L.V 006--7 506000-E ELC-ENNDR/T ELC-E6NNDR/T ELC-ENNDN ELC-ENNAN ELC-ENNNR/T ELC-E6NNNI Instruction Sheet Digital Input Digital Output Module WARNING This Instruction Sheet provides descriptions

More information

VersaMax* Analog Input, 16-Bit Thermocouple Module

VersaMax* Analog Input, 16-Bit Thermocouple Module VersaMax* Analog Input, 16-Bit Module Product Description The Analog Input Module is an intelligent module that accepts seven independent thermocouple or millivolt inputs. The module receives power from

More information