Cisco HyperFlex HX240c M4 Node

Size: px
Start display at page:

Download "Cisco HyperFlex HX240c M4 Node"

Transcription

1 Spec Sheet Cisco HyperFlex HX240c M4 Node CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.10 JANUARY 12,

2 CONTENTS OVERVIEW DETAILED VIEWS Chassis Front View Chassis Rear View BASE HX240c NODE STANDARD CAPABILITIES and FEATURES CONFIGURING the HX240c M4 Node STEP 1 VERIFY SKU STEP 2 SELECT RISER CARD (OPTIONAL) STEP 3 SELECT CPU(s) STEP 4 SELECT MEMORY STEP 5 SELECT DRIVE CONTROLLER SAS HBA (internal HDD/SSD/non-RAID support) STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) STEP 7 SELECT PCIe OPTION CARD(s) STEP 8 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL) STEP 9 ORDER POWER SUPPLY STEP 10 SELECT AC POWER CORD(s) STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM. 27 STEP 12 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) STEP 13 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE STEP 14 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE STEP 15 SELECT SERVICE and SUPPORT LEVEL OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER PDU SUPPLEMENTAL MATERIAL Hyperconverged Systems Chassis Block Diagram CPUs and DIMMs Physical Layout Memory Population Rules DIMM Population Order Serial Port Details Upgrade and Servicing-Related Parts Adding an Additional CPU (with CPU heat sink) or Replacing CPUs Motherboard Lithium Battery Thermal Grease (with syringe applicator) for CPU to Heatsink Seal Air Baffle Replacement Kit CPU Heat Sink Cleaning Kit Riser Card Configuration and Options RACKS PDUs KVM CABLE TECHNICAL SPECIFICATIONS Dimensions and Weight Power Specifications Environmental Specifications Compliance Requirements

3 OVERVIEW OVERVIEW Cisco HyperFlex Systems unlock the full potential of hyperconvergence. The systems are based on an end-to-end software-defined infrastructure, combining software-defined computing in the form of Cisco Unified Computing System (Cisco UCS) servers; software-defined storage with the powerful Cisco HX Data Platform and software-defined networking with the Cisco UCS fabric that will integrate smoothly with Cisco Application Centric Infrastructure (Cisco ACI ). Together with a single point of connectivity and hardware management, these technologies deliver a preintegrated and adaptable cluster that is ready to provide a unified pool of resources to power applications as your business needs dictate. Figure 1 Cisco HX240c M4 Node (24-drive) Front View Rear View 3

4 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the 24-drive Cisco HX240c M4 Node (with front bezel removed). Figure 2 Chassis Front View (24-drive version) 1 2 HDD24 HDD23 HDD22 HDD21 HDD20 HDD19 HDD18 HDD17 HDD16 HDD15 HDD14 HDD13 HDD12 HDD11 HDD10 HDD09 HDD08 HDD07 HDD06 HDD05 HDD04 HDD03 HDD02 HDD Front Mount Drives 1 Up to 23 x 1.2 TB SAS HDDs (for data) 1 x 1.6 TB SATA SSD (for caching) 7 Temperature status LED 2 Operations panel buttons and LEDs 8 Power supply status LED 3 Power button/led 9 Network link activity LED 4 Unit Identification button/led 10 Pull-out asset tag 5 System status LED 11 KVM connector 6 Fan status LED Notes x 120 GB SATA SSD internal drive (on PCIe riser) is used for SDS logs (used with KVM cable that provides two USB 2.0, one VGA, and one serial connector) For more information about the KVM cable connection, see KVM CABLE, page 52. 4

5 DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel. Figure 3 Chassis Rear View PCIe 03 PCIe 02 PCIe 06 PCIe 05 PSU PCIe 01 mlom PCIe 04 PSU PCIe riser 1 (slots 1, 2, 3) 7 Serial connector (RJ-45) 1 2 PCIe riser 2 (slots 4, 5, 6) 8 Two embedded (on the motherboard) Intel i350 GbE Ethernet controller ports (LAN1, LAN2) 3 Power supplies (DC power supplies shown) 9 VGA video port (DB-15 connector) 4 Modular LAN-on-motherboard (mlom) card slot Notes For serial port pinout details, see Serial Port Details, page Rear Unit Identification button/led 5 USB 3.0 ports (two) 11 Grounding-lug holes (for DC power supplies) 6 1-Gbps dedicated management port 5

6 BASE HX240c NODE STANDARD CAPABILITIES and FEATURES BASE HX240c NODE STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base node. Details about how to configure the node for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the HX240c M4 Node, page 8. Table 1 Capabilities and Features Capability/Feature Chassis CPU Chipset Memory Multi-bit Error Protection Embedded NIC Expansion slots Video Internal storage devices Cisco Flexible Flash drives Description Two rack unit (2RU) chassis Two Intel Xeon E v3 or v4 series processor family CPUs Intel C610 series chipset 24 slots for registered ECC DIMMs (RDIMMs) Supports multi-bit error protection. Two embedded (on the motherboard) Intel i350 GbE ports, supporting the following: Pre-Execution Boot (PXE boot) iscsi boot Checksum and segmentation offload NIC teaming Up to six PCIe slots (on two riser cards) Riser 1 (PCIe slots 1, 2, and 3), controlled by CPU 1 Riser 2 (PCIe slots 4, 5, and 6), controlled by CPU 2. If GPU is ordered, it goes into slot 5. Dedicated disk controller slot (see Figure 7 on page 39) An internal slot is reserved for use by the Cisco 12 Gbps Modular SAS HBA. The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller: Integrated 2D graphics core with hardware acceleration DDR2/3 memory interface supports up to 512 MB of addressable memory (8 MB is allocated by default to video memory) Supports display resolutions up to 1920 x Hz High-speed integrated 24-bit RAMDAC Single lane PCI-Express host interface running at Gen 1 speed Drives are installed into front-panel drive bays that provide hot-pluggable access. Small Form Factor (SFF) drives. Up to TB front-mounting SAS HDDs (for data) One 1.6 TB front-mounting SATA SSD (for caching) One 120 GB internal SATA SSD (for SDS logs) The system supports two internal 64 GB Cisco Flexible Flash drives (SD cards). The SD cards are mirrored to each other and are used for booting. 6

7 BASE HX240c NODE STANDARD CAPABILITIES and FEATURES Capability/Feature Interfaces Rear panel Power subsystem Modular LAN on Motherboard (mlom) slot WoL Front Panel One DB15 VGA connector One RJ45 serial port connector Two USB 3.0 port connectors One RJ-45 10/100/1000 Ethernet management port, using Cisco Integrated Management Controller (CIMC) firmware Two Intel i350 embedded (on the motherboard) GbE LOM ports One flexible modular LAN on motherboard (mlom) slot that accommodates the Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ interface card. Two PCIe 3.0 slots Front panel One KVM console connector (supplies two USB 2.0 connectors, one VGA DB15 video connector, and one serial port (RS232) RJ45 connector) Up to two of the following hot-swappable power supplies: 650 W (AC) 930 W (DC) 1200 W (AC) 1400 W (AC) One power supply is mandatory; one more can be added for redundancy. The mlom slot accommodates the following card: Cisco VIC 1227 Virtual Interface Cards The 1-Gb Base-T Ethernet LAN ports support the wake-on-lan (WoL) standard. A front panel controller provides status indications and control buttons ACPI This system supports the advanced configuration and power interface (ACPI) 4.0 standard. Fans Chassis: Six hot-swappable fans for front-to-rear cooling Storage controller Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity Integrated management processor Description Supports up to 23 front-mount HDDS (for data), one front-mount SSD (for caching) and one internal SSD drive (for SDS logs) Plugs into a dedicated internal disk controller slot No RAID support Baseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware. Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface card (VIC). 7

8 CONFIGURING the HX240c M4 Node CONFIGURING the HX240c M4 Node For the most part, this system comes with a fixed configuration. Follow these steps to see or change the configuration of the HX240c M4 Node: STEP 1 VERIFY SKU, page 9 STEP 3 SELECT CPU(s), page 11 STEP 4 SELECT MEMORY, page 14 STEP 5 SELECT DRIVE CONTROLLER, page 18 STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 19 STEP 7 SELECT PCIe OPTION CARD(s), page 20 STEP 8 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL), page 21 STEP 10 SELECT AC POWER CORD(s), page 24 STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 27 STEP 12 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 28 STEP 13 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE, page 29 STEP 14 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 30 STEP 15 SELECT SERVICE and SUPPORT LEVEL, page 31 OPTIONAL STEP - ORDER RACK(s), page 35 OPTIONAL STEP - ORDER PDU, page 36 8

9 CONFIGURING the HX240c M4 Node STEP 1 VERIFY SKU Verify the product ID (PID) from Table 2. Table 2 PID of the HX240c M4 Node Product ID (PID) HX240C-M4SX Description HX240c M4 Node, with two CPUs, memory, 23 HDDs, two SSDs, two power supplies, two SD cards, one VIC 1227 mlom card, no PCIe cards, and no rail kit The HX240c M4 Node: Includes two power supplies, two CPUs, memory, hard disk drives (HDDs), solid-state drives (SSDs), VIC 1227 mlom card, and SD cards Does not include rail kit or plug-in PCIe cards. NOTE: Use the steps on the following pages to see or change the configuration of the system. 9

10 CONFIGURING the HX240c M4 Node STEP 2 SELECT RISER CARD (OPTIONAL) There is one optional riser card, riser card 2. Order one riser card 2 from Table 3. Riser card 2 is the one on the right when viewed from the back of the server, and provides slots 4, 5, and 6. Table 3 Riser 2 Options Product ID (PID) Description UCSC-PCI-2-C240M4 PCIe Riser Board (Riser 2) for HXC240c M4 (3 slots: 2x8 and 1x16) NOTE: If no riser is selected, a riser blanking panel will be installed. You will not be able to install any PCIe cards without a riser selected For additional details, see Riser Card Configuration and Options, page

11 CONFIGURING the HX240c M4 Node STEP 3 SELECT CPU(s) The standard CPU features are: Intel Xeon E v3 or v4 series processor family CPUs Intel C610 series chipset Cache size of up to 55 MB Select CPUs The available CPUs are listed in Table 4. Table 4 Available Intel CPUs Highest Product ID (PID) Clock Cache DDR4 DIMM Intel Power Freq Size Cores QPI Clock Number (W) (GHz) (MB) Support (MHz) 1 E v4 Series Processor Family CPUs UCS-CPU-E52699E E v GT/s 2400 UCS-CPU-E52698E E v GT/s 2400 UCS-CPU-E52697AE E5-2697A v GT/s 2400 UCS-CPU-E52697E E v GT/s 2400 UCS-CPU-E52695E E v GT/s 2400 UCS-CPU-E52690E E v GT/s 2400 UCS-CPU-E52683E E v GT/s 2400 UCS-CPU-E52680E E v GT/s 2400 UCS-CPU-E52667E E v GT/s 2400 UCS-CPU-E52660E E v GT/s 2400 UCS-CPU-E52650E E v GT/s 2400 UCS-CPU-E52650LE E5-2650L v GT/s 2400 UCS-CPU-E52640E E v GT/s 2133 UCS-CPU-E52630E E v /0 GT/s 2133 UCS-CPU-E52630LE E5-2630L v GT/s 2133 UCS-CPU-E52620E E v GT/s 2133 UCS-CPU-E52609E E v GT/s 1866 UCS-CPU-E52658E E v GT/s

12 CONFIGURING the HX240c M4 Node Table 4 Available Intel CPUs (continued) Product ID (PID) Intel Number E v3 Series Processor Family CPUs Clock Freq (GHz) Power (W) Cache Size (MB) Cores UCS-CPU-E52699D E v GT/s 2133 UCS-CPU-E52698D E v GT/s 2133 UCS-CPU-E52697D E v GT/s 2133 UCS-CPU-E52695D E v GT/s 2133 UCS-CPU-E52690D E v GT/s 2133 UCS-CPU-E52683D E v GT/s 2133 UCS-CPU-E52680D E v GT/s 2133 UCS-CPU-E52670D E v GT/s 2133 UCS-CPU-E52667D E v GT/s 2133 UCS-CPU-E52660D E v GT/s 2133 UCS-CPU-E52658D E v GT/s 2133 UCS-CPU-E52650D E v GT/s 2133 UCS-CPU-E52650LD E5-2650L v GT/s 2133 UCS-CPU-E52640D E v GT/s 1866 UCS-CPU-E52630D E v GT/s 1866 UCS-CPU-E52630LD E5-2630L v GT/s 1866 Notes If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. QPI Highest DDR4 DIMM Clock Support (MHz) 1 12

13 CONFIGURING the HX240c M4 Node Approved Configurations (1) 2-CPU Configurations: Caveats Select two identical CPUs from any one of the rows of Table 4 on page 11. You must select two identical processors. For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 4 on page 11). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. 13

14 CONFIGURING the HX240c M4 Node STEP 4 SELECT MEMORY The standard memory features are: DIMMs Clock speed: 2400 and 2133 MHz Ranks per DIMM: 1, 2, 4, or 8 Operational voltage: 1.2 V Registered ECC DDR4 DIMMs (RDIMMs), load-reduced DIMMS (LR-DIMMs), or thru-silicon-via DIMMs (TSV-DIMMs). Memory is organized with four memory channels per CPU, with up to three DIMMs per channel, as shown in Figure 4. Figure 4 HX240c M4 Mode Memory Organization Slot 1 Slot 2 Slot 3 A1 A2 A3 Slot 3 E3 Slot 2 Slot 1 E2 E1 Chan A Chan E B1 B2 B3 F3 F2 F1 Chan B Chan F C1 C2 C3 CPU 1 CPU 2 G3 G2 G1 Chan C Chan G D1 D2 D3 H3 H2 H1 Chan D Chan H 24 DIMMS 1.5 TB maximum memory (with 64 GB DIMMs) 4 memory channels per CPU, up to 3 DIMMs per channel 14

15 CONFIGURING the HX240c M4 Node Select DIMMs Select the desired DIMMs from Table 5. Table 5 Available DDR4 DIMMs Product ID (PID) PID Description Voltage Ranks/ DIMM DIMM Options 2400-MHz DIMM Options UCS-ML-1X644RV-A 64 GB DDR MHz LRDIMM/PC /quad rank/x4 1.2 V 4 UCS-MR-1X322RV-A 32GB DDR MHz RDIMM/PC /dual rank/x4 1.2 V 2 UCS-MR-1X161RV-A 16GB DDR MHz RDIMM/PC /single rank/x4 1.2 V MHz DIMM Options UCS-MR-1X648RU-A 64 GB DDR MHz TSV-RDIMM/PC /octal rank/x4 1.2 V 8 UCS-MR-1X322RU-A 32GB DDR MHz RDIMM/PC /dual rank/x4 1.2 V 2 UCS-MR-1X162RU-A 16GB DDR MHz RDIMM/PC /dual rank/x4 1.2 V 2 Approved Configurations (1) 2-CPU configuration: Select either 8 or 12 identical DIMMs per CPU (16 or 24 total identical DIMMs). Refer to Memory Population Rules, page 42, for more detailed information. NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the system. 15

16 CONFIGURING the HX240c M4 Node Caveats System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support. See Table 6 for details. Table 6 DIMM Memory Speeds with Different CPUs DIMM Speed DPC 1866-MHz Capable CPU RDIMM (DR) 2133-MHz Capable CPU RDIMM (DR) 2133 DIMM 1 3 DPC (32 GB RDIMMs and 16 GB DIMMs) 2 DPC DPC Notes MHz DIMMs are the only offered and supported DIMMs for the HX220c M4 Node. Table MHz DIMM Memory Speeds with Different v4 CPUs DIMM and CPU Frequencies DPC LRDIMM (QRx4) - 64 GB RDIMM (2Rx4) - 32 GB RDIMM (SRx4) - 16 GB 1.2 V 1.2 V 1.2 V DIMM = 2400 MHz CPU = 2400 MHz 1DPC 2400 MHz 2400 MHz 2400 MHz 2DPC 2400 MHz 2400 MHz 2400 MHz 3DPC 2133 MHz 1866 MHz 2133 MHz DIMM = 2400 MHz CPU = 2133 MHz 1DPC 2133 MHz 2133 MHz 2133 MHz 2DPC 2133 MHz 2133 MHz 2133 MHz 3DPC 1866 MHz 1866 MHz 1866 MHz DIMM = 2400 MHz CPU = 1866 MHz 1DPC 1866 MHz 1866 MHz 1866 MHz 2DPC 1866 MHz 1866 MHz 1866 MHz 3DPC 1866 MHz 1600 MHz 1600 MHz The HX240c M4 Node supports the following memory reliability, availability, and serviceability (RAS) modes: Independent Channel Mode Lockstep Channel Mode Below are the system level RAS Mode combination limitations: Mixing of Independent and Lockstep channel mode is not allowed per platform. DIMMs for CPU 1 and CPU 2 must always be configured identically. 16

17 CONFIGURING the HX240c M4 Node Non-ECC DIMMs are not supported. Pairs of DIMMs (A1/B1, A2/B2, etc) MUST be the exact same (same PID, rev, DIMM loading order) Cisco memory from previous generation systems (DDR3) is not compatible with this system For more information regarding memory, see CPUs and DIMMs, page

18 CONFIGURING the HX240c M4 Node STEP 5 SELECT DRIVE CONTROLLER SAS HBA (internal HDD/SSD/non-RAID support) Choose the following SAS HBA for internal drive connectivity (non-raid): Cisco 12 Gbps Modular SAS HBA, which plugs into a dedicated RAID controller slot. Select Controller Options Select the following: Cisco 12 Gbps Modular SAS HBA (see Table 8) Table 8 Hardware Controller Options Product ID (PID) Controllers for Internal Drives PID Description Note that the following Cisco 12Gbps Modular SAS HBA controller is factory-installed in the dedicated internal slot. UCSC-SAS12GHBA Cisco 12 Gbps Modular SAS HBA Supports up to 24 internal SAS HDDs and SAS/SATA SSDs No RAID functionality. Ideal for SDS (Software Defined Storage) applications. It is also ideal for environments demanding the highest IOPs (for external SSD attach), where a RAID controller can be an I/O bottleneck. Approved Configurations The Cisco 12 Gbps Modular SAS HBA supports up to 24 internal drives with non-raid support. 18

19 CONFIGURING the HX240c M4 Node STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) The standard disk drive features are: 2.5-inch small form factor Hot-pluggable Drives come mounted in sleds Select Drives The available drives are listed in Table 9. Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs Product ID (PID) HDD Data Drive PID Description Drive Type Capacity UCS-HD12TB10K12G 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB SATA SSD Caching Drive UCS-SD16TB12S3-EP 1.6 TB 2.5 inch Enterprise Performance 6G SATA SSD (3X endurance) SATA 1.6 TB SATA SSD SDS Logs Drive UCS-SD120GBKS4-EB 120 GB 2.5 inch Enterprise Value 6G SATA SSD SATA 120 GB Approved Configurations (1) Cisco 12 Gbps Modular SAS HBA Caveats Select the following drives: Up to 23 front-mount 1.2 TB 12G SAS 10K RPM SFF HDD data drives (UCS-HD12TB10K12G) One front-mount 1.6 TB 2.5 inch Enterprise Performance 6G SATA SSD caching drive (UCS-SD16TB12S3-EP) One internal 120 GB 2.5 inch Enterprise Value 6 G SATA SSD SDS logs drive (UCS-SD120GBKS4-EB) See SELECT DRIVE CONTROLLER, page 18 for more details. You must choose up to 23 HDDs for data, one SSD caching drive, and one SATA SSD SDS logs drive. 19

20 CONFIGURING the HX240c M4 Node STEP 7 SELECT PCIe OPTION CARD(s) The standard PCie card offerings is: Modular LAN on Motherboard (mlom) Select PCIe Option Card The available PCIe option card is listed in Table 10. Table 10 Available PCIe Option Cards Product ID (PID) PID Description Card Height Modular LAN on Motherboard (mlom) 1 UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ N/A Notes The mlom card does not plug into any of the riser 1 or riser 2 card slots; instead, it plugs into a connector inside the chassis. Caveats Other considerations for the Cisco VIC 1227 card: VIC 1227 supports 10G SFP+ optical and copper twinax connections The VIC 1227 is supported with the following software releases: 2.0.8h (CIMC) and above, and 2.2.6f (UCSM). 20

21 CONFIGURING the HX240c M4 Node STEP 8 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL) Select GPU Options The available GPU PCIe options are listed in Table 11. Table 11 Available PCIe Option Cards Product ID (PID) PID Description Card Size GPU PCIe Cards UCSC-GPU-VGXK1 NVIDIA GRID K1 Full-height, double wide UCSC-GPU-VGXK2 NVIDIA GRID K2 Full-height, double wide UCSC-GPU-M60 1 M60 GPU GRID 2.0 Notes Requires 300 W cable kit (UCS-300WKIT-240M4) Full-height, double wide CAUTION: When using GPU cards, the operating temperature range is 32 to 95 F (0 to 35 C). NOTE: All GPU cards require two CPUs and a minimum of two power supplies in the server W power supplies are recommended. Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): Select GPU Power Cables Whenever you select a K1 or K2 GPU for this server, you must also select one power cable for each GPU selected (however, a maximum of one GPU can be selected). The available GPU power cables are listed in Table 12. Table 12 Available GPU Power Cables Product ID (PID) UCSC-GPUCBL-240M4 PID Description C240 M4 GPU Power Cable 21

22 CONFIGURING the HX240c M4 Node Caveats NVIDIA GPUs can support only less than 1 TB of total memory in the server. Do not install more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server. NVIDIA GRID K1 and K2 GPUs can be mixed. No other GPU mixing is allowed. Slot 5 on optional riser card 2 is the required slot for the GPU. A maximum of one GPU can be installed. If a GPU is installed, the chassis must be equipped with either a 1200 W or 1400 W power supply. 22

23 CONFIGURING the HX240c M4 Node STEP 9 ORDER POWER SUPPLY The HX240c M4 node requires at least one power supply. A lightly loaded system may require one or two 650 W power supplies. A fully loaded system might need to be powered with two larger capacity power supplies. Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): Table 13 Power Supply 1 Product ID (PID) UCSC-PSU2-1400W UCSC-PSU2V2-1200W 2 UCSC-PSU-930WDC UCSC-PSU2V2-650W PID Description 1400W AC Power Supply ( V) 2U & 4U C Series System 1200W / 800W V2 AC Power Supply for 2U C-Series Systems 930 W -48V DC Common Slot Power Supply for C-series Systems 650W V2 AC Power Supply for C-Series Systems Notes If a GPU is installed, the chassis must be equipped with a 1200 W or 1400 W power supply. 2. The power output is 1200W with a V input and 800W with a V input. NOTE: In a two power supply system, both power supplies must be identical. 23

24 CONFIGURING the HX240c M4 Node STEP 10 SELECT AC POWER CORD(s) Using Table 14, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the system. Table 14 Available Power Cords Product ID (PID) PID Description Images R2XX-DMYMPWRCORD CAB-N5K6A-NA No power cord (dummy PID to allow for a no power cord option) Power Cord, 200/240V 6A, North America Not applicable Plug: NEMA 6-15P Cordset rating: 10 A, 250 V Length: 8.2 ft Connector: IEC60320/C CAB-AC-L620-C13 AC Power Cord, NEMA L C13, 2M/6.5ft CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M 24

25 16A 250V OVE CONFIGURING the HX240c M4 Node Table 14 Available Power Cords Product ID (PID) PID Description Images CAB-250V-10A-AR Power Cord, 250V, 10A, Argentina 2500 mm Plug: EL 219 (IRAM 2073) Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Connector: EL 701 (IEC60320/C13) CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, Australia Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Plug: EL 210 (BS 1363A) 13 AMP fuse Connector: EL 701C (EN 60320/C15) CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7 Plug, EU Plug: M2511 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: VSCC SFS-250V-10A-ID Power Cord, SFS, 250V, 10A, India Plug: EL 208 Cordset rating 16A, 250V (2500mm) Connector: EL SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel EL-212 Cordset rating 10A, 250V/500V MAX (2500 mm) Plug: EL 212 (SI-32) Connector: EL 701B (IEC60320/C13) CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Plug: I/3G (CEI 23-16) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 )

26 From Plug End CONFIGURING the HX240c M4 Node Table 14 Available Power Cords Product ID (PID) PID Description Images CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) Connector: IEC C CAB-9K10A-UK Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Plug: EL 210 (BS 1363A) 13 AMP fuse Connector: EL 701C (EN 60320/C15) CAB-9K12A-NA Power Cord, 125VAC 13A NEMA 5-15 Plug, North America CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil 2,133.6 ± 25 CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available 26

27 CONFIGURING the HX240c M4 Node STEP 11 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM Select a Tool-Less Rail Kit Select a tool-less rail kit from Table 15. Table 15 Tool-Less Rail Kit Options Product ID (PID) UCSC-RAILB-M4 PID Description Ball Bearing Rail Kit Select an Optional Reversible Cable Management Arm The reversible cable management arm mounts on either the right or left slide rails at the rear of the system and is used for cable management. Use Table 16 to order a cable management arm. Table 16 Cable Management Arm Product ID (PID) UCSC-CMA-M4 PID Description Reversible CMA for tool-less ball bearing rail kit For more information about the tool-less rail kit and cable management arm, see the Cisco UCS C240 M4 Installation and Service Guide at this URL: NOTE: If you plan to rackmount your HX240c M4 node, you must order a tool-less tool-less rail kit. 27

28 CONFIGURING the HX240c M4 Node STEP 12 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (system). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments. The TPM ordering information is listed in Table 17. Table 17 Trusted Platform Module Product ID (PID) UCSX-TPM2-001 PID Description Trusted Platform Module 1.2 SPI-based NOTE: The module used in this system conforms to TPM v1.2 and 2.0, as defined by the Trusted Computing Group (TCG). It is also SPI-based. 28

29 CONFIGURING the HX240c M4 Node STEP 13 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE You must order two 64 GB SD cards. The SD cards are mirrored to each other and are used for booting. See Figure 7 on page 39 for the location of the SD cards. There are two locations, SD1 and SD2. Table GB Secure Digital (SD) Card Product ID (PID) UCS-SD-64G-S PID Description 64 GB SD Card Caveats You must select two 64 GB SD cards 29

30 CONFIGURING the HX240c M4 Node STEP 14 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE Several operating systems and value-added software programs are available. Select as desired from Table 1. Table 19 OSs and Value-Added Software PID Description Product ID (PID) VMware 1 HX-VSP-STD-D HX-VSP-STD-DL HX-VSP-EPL-D HX-VSP-EPL-DL HX-VSP-FND-D HX-VSP-FND-DL HX-VSP-STD-D HX-VSP-STD-DL Software Subscription HXDP-001-2YR HXDP-001-4YR Factory Installed - VMware vsphere6 Std SW and Lic (2 CPU) Factory Installed - VMware vsphere6 Standard SW Download Factory Installed - VMware vsphere6 Ent Plus SW+Lic (2 CPU) Factory Installed - VMware vsphere6 Enterprise Plus SW Dnld Factory Installed - vsphere SW (End user to provide License) Factory Installed - VMware vsphere6 Foundation SW Download Factory Installed - VMware vsphere6 Std SW and Lic (2 CPU) Factory Installed - VMware vsphere6 Standard SW Download Cisco HyperFlex HX Data Platform SW 1 Yr Subscription Cisco HyperFlex HX Data Platform SW 3 Yr Subscription HXDP-S001-1YR= Cisco HyperFlex HX Data Platform SW 1 yr Subscription v2.0 HXDP-S001-2YR= Cisco HyperFlex HX Data Platform SW 2 yr Subscription v2.0 HXDP-S001-3YR= Cisco HyperFlex HX Data Platform SW 3 yr Subscription v2.0 HXDP-S001-4YR= Cisco HyperFlex HX Data Platform SW 4 yr Subscription v2.0 HXDP-S001-5YR= Cisco HyperFlex HX Data Platform SW 5 yr Subscription v2.0 Notes Although VMware 6.0 is installed at the factory, both VMware 5.5 and VMware 6.0 are supported. 30

31 CONFIGURING the HX240c M4 Node STEP 15 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: Three-year parts coverage. Next business day (NBD) onsite parts replacement eight hours a day, five days a week. 90-day software warranty on media. Ongoing downloads of BIOS, drivers, and firmware updates. UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards. Smart Net Total Care for UCS For support of the entire Unified Computing System, Cisco offers the Cisco Smart Net Total Care for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco Smart Net Total Care for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table 20. Table 20 Cisco Smart Net Total Care for UCS Service Product ID (PID) On Site? Description CON-PREM-HX240M4S Yes ONSITE 24X7X2 HX240C M4 SFF - SFF CON-OSPT-HX240M4S Yes ONSITE Troubleshooting 24x7x4 HX240C M4 SFF-SFF CON-C4P-HX240M4S Yes ONSITE 24X7X4 HX240C M4 SFF - SFF CON-OSE-HX240M4S Yes ONSITE 8X5X4 HX240C M4 SFF - SFF CON-OS-HX240M4S Yes ONSITE 8X5XNBD HX240C M4 SFF - SFF CON-S2P-HX240M4S No SMARTNET 24X7X2 HX240C M4 SFF - SFF CON-SNTP-HX240M4S No SMARTNET 24X7X4 HX240C M4 SFF - SFF CON-SNTE-HX240M4S No SMARTNET 8X5X4 HX240C M4 SFF - SFF CON-SNT-HX240M4S No SMARTNET 8X5XNBD HX240C M4 SFF - SFF 31

32 CONFIGURING the HX240c M4 Node Unified Computing Partner Support Service Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them: Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice. PSS is available to all Cisco PSS partners. The Partner Unified Computing Support Option for the Cisco HX240C Node is: Partner Support Service for UCS Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. See Table 21. Table 21 Partner Support Service for UCS Product ID (PID) Service Level GSP On Site? Description CON-PSJ1-HX240M4S PSJ1 No UCS SUPP PSS 8X5XNBD HX240C M4 SFF - SFF CON-PSJ2-HX240M4S PSJ2 No UCS SUPP PSS 8X5X4 HX240C M4 SFF - SFF CON-PSJ3-HX240M4S PSJ3 No UCS SUPP PSS 24X7X4 HX240C M4 SFF - SFF CON-PSJ4-HX240M4S PSJ4 No UCS SUPP PSS 24X7X2 HX240C M4 SFF - SFF Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract. Smart Net Total Care services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to: Optimize the uptime, performance, and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in-house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources 32

33 CONFIGURING the HX240c M4 Node Enhance business agility by diagnosing potential issues before they affect your operations You can choose a service listed in Table 22. Table 22 UCS Computing Combined Support Service Product ID (PID) Service Level GSP On Site? Description CON-NCF2-HX240M4S NCF2 No CMB SPT SVC 24X7X2 HX240C M4 SFF - SFF CON-NCF2P-HX240M4S NCF2P Yes CMB SPT SVC 24X7X2OS HX240C M4 SFF - SFF CON-NCF4P-HX240M4S NCF4P Yes CMB SPT SVC 24X7X4OS HX240C M4 SFF - SFF CON-NCF4S-HX240M4S NCF4S Yes CMB SPT SVC 8X5X4OS HX240C M4 SFF - SFF CON-NCFCS-HX240M4S NCFCS Yes CMB SPT SVC 8X5XNBDOS HX240C M4 SFF - SFF CON-NCFE-HX240M4S NCFE No CMB SPT SVC 8X5X4 HX240C M4 SFF - SFF CON-NCFP-HX240M4S NCFP No CMB SPT SVC 24X7X4 HX240C M4 SFF - SFF CON-NCFT-HX240M4S NCFT No CMB SPT SVC 8X5XNBD HX240C M4 SFF - SFF Smart Net Total Care for UCS with Drive Retention With the Smart Net Total Care for UCS with Drive Retention (UCSDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed. Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements. If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 23 on page 34. NOTE: Cisco does not offer a certified drive destruction service as part of this service. 33

34 CONFIGURING the HX240c M4 Node Table 23 Drive Retention Service Options Service Description Service Program Name Service Level GSP Service Level Product ID (PID) Smart Net Total Care for UCS with Drive Retention UCS DR UCSD8 24x7x2 Onsite CON-UCSD8-HX240M4S OSPTD 24x7x4 Onsite Troubleshooting CON-OPSTD-HX240M4S UCSD7 24x7x4 Onsite CON-UCSD7-HX240M4SF UCSD5 8x5xNBD Onsite CON-UCSD5-HX240M4SF For a complete listing of available services for Cisco Unified Computing System, see this URL: 34

35 OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series systems, including the HX240c M4 Node. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 24. Racks are shipped separately from the HX240c M4 Node. Table 24 Racks and Rack Options Product ID (PID) RACK-UCS 1 RACK-UCS2 1 RACK-BLANK-001 RACK-CBLMGT-001 RACK-CBLMGT-011 RACK-FASTEN-001 RACK-FASTEN-002 RACK-JOIN-001 PID Description Cisco R42610 expansion rack, no side panels Cisco R42610 standard rack, w/side panels Filler panels (qty 12), 1U, plastic, toolless Cable mgt D rings (qty 10), metal Cable mgt straps (qty 10), Velcro Mounting screws (qty 100), M6 Cage nuts (qty 50), M6 Rack joining kit Notes Use these same base PIDs to order spare racks (available only as next-day replacements). For more information about the R42610 rack, see RACKS, page

36 OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack systems, including the HX240c M4 Node. This PDU is available in a zero rack unit (RU) style (see Table 25). Table 25 PDU Options Product ID (PID) RP P-U-2 PID Description Zero RU PDU For more information about the PDU, see PDUs, page

37 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL Hyperconverged Systems Cisco HyperFlex Systems let you unlock the full potential of hyperconvergence and adapt IT to the needs of your workloads. The systems use an end-to-end software-defined infrastructure approach, combining software-defined computing in the form of Cisco HyperFlex HX-Series nodes; software-defined storage with the powerful Cisco HX Data Platform; and software-defined networking with the Cisco UCS fabric that will integrate smoothly with Cisco Application Centric Infrastructure (Cisco ACI). Together with a single point of connectivity and management, these technologies deliver a preintegrated and adaptable cluster with a unified pool of resources that you can quickly deploy, adapt, scale, and manage to efficiently power your applications and your business. Figure 5 shows a small footprint cluster and Figure 6 shows a compute-intensive hybrid cluster. Figure 5 Small Footprint Cluster Using HX420c M4 Nodes Cisco HyperFlex Systems Connectivity (small footprint cluster) Cisco Nexus 9000 Series Switch (optional) Cisco Nexus 9000 Series Switch (optional) vpc Shared Services peer link vcenter Cisco UCS 6248UP Fabric Interconnect vpc vpc Cisco UCS 6248UP Fabric Interconnect DHCP NTP DNS Active Directory Legend Cisco HX240c M4 Nodes (3 minimum) Converged 10 GbE Interconnects Each HX240c M4 Node contains: - 2 x Intel Xeon CPU E (v3 2.5 GHz processor) GB (24 x 16 GB DDR4) RAM - 1 x Cisco 12G SAS HBA - 1 x 120 GB SATA SSD - 1 x 1.6 TB SATA SSD - 23 x 1.2 TB SAS 12 Gbs10K RPM HDDs - Cisco VIC1227 MLOM (2 x 10G ports) - 2 x 64 GB SD Cards 37

38 SUPPLEMENTAL MATERIAL Figure 6 Compute-Intensive Hybrid Cluster Using HX240c M4 Nodes and B200 M4 Blades Cisco HX Connectivity (compute-intensive hybrid cluster) Cisco Nexus 9000 Series Switch (optional) Cisco Nexus 9000 Series Switch (optional) vpc Shared Services peer link vcenter Cisco UCS 6248UP Fabric Interconnect vpc vpc Cisco UCS 6248UP Fabric Interconnect DHCP NTP DNS Active Directory Legend Cisco UCS HX240c M4 Nodes (3 minimum) Converged 10 GbE Interconnects CiscoUCS 5108 BladeChassis With 3 x B200 M4 Blades Each HX240c M4 contains: - 2 x Intel Xeon CPU E (v3 2.5 GHz processor) GB (24 x 16 GB DDR4) RAM - 1 x Cisco 12G SAS HBA - 1 x 120 GB SATA SSD - 1 x 1.6 TB SATA SSD - 23 x 1.2 TB SAS 12 Gbs10K RPM HDDs - Cisco VIC1227 MLOM (2 x 10G ports) - 2 x 64 GB SD Cards Each B200 M4 blade contains: - 2 x Intel Xeon ES-2680 v3 2.5 GHz processors GB (24 x 16 GB DDR4) RAM - Cisco VIC x 64 GB SD Cards. 38

39 SUPPLEMENTAL MATERIAL Chassis An internal view of the HX240c M4 Node chassis with the top cover removed is shown in Figure 7. The location of the two SD cards is marked with callout #5 and the location of the SATA SSD SDS logs drives is marked with callout #11. Figure 7 HX240c M4 Node Chassis With Top Cover Off FAN 06 SD2 SD1 7 1 FAN 05 FAN 04 FAN 03 FAN 02 FAN 01 CPU 2 CPU 1 Riser 2 Riser Drives (SAS/SATA drives are hot-swappable) 10 PCIe riser 1 (PCIe slots 1, 2, 3*) 2 Fan modules (six, hot-swappable) 11 SATA SSD SDS logs drives (two sockets available only on PCIe riser 1) 3 DIMM sockets on motherboard (either 16 or 24 DIMMs populated) 12 mlom card socket on motherboard under PCIe riser 1 4 CPUs and heatsinks (two) 13 Socket for embedded RAID interposer board (not used) 5 Cisco SD card slots on motherboard (two) 14 Cisco modular drive controller PCIe slot (dedicated slot and bracket) 6 USB 3.0 slot on motherboard (not used) 15 RTC battery on motherboard 7 Power supplies (hot-swappable, accessed through rear panel) 8 Trusted platform module (TPM) socket on motherboard, under PCIe riser 2 9 PCIe riser 2 (PCIe slots 4, 5, 6) 16 Embedded RAID header for RAID key (not used) 17 SuperCap power module (RAID backup) mounting location on air baffle (not shown) (not used) 39

40 SUPPLEMENTAL MATERIAL Block Diagram A simplified block diagram of the HX240c M4 Node is shown in Figure 8. Figure 8 HX240c M4 Node Block Diagram (simplified) UCSC-C240-M4S, 2U, 8-2.5" drives X4 SAS Connector SAS x4 SAS x4 UCSC-C240-M4S2, 2U, " drives 24-port SAS Expander X4 SAS Connector SAS x4 X4 SAS Connector... X4 SAS Connector. SAS x4 UCSC-C240-M4SX, 2U, " drives 36-port SAS Expander SAS x4 X4 SAS Connector... X4 SAS Connector. SAS x4 UCSC-C240-M4L, 2U, " drives 20-port SAS Expander SATA SAS x4 X4 SAS Connector... X4 SAS Connector X4 SAS Connector X4 SAS Connector Cables to modular RAID card or Wellsburg connectors or PCIe Interposer* SATA Cables to modular RAID card connectors or PCIe Interposer* A1A2 A3 B1B2 B3 Chan A Chan B C1C2 C3 Chan C D1D2 D3 Chan D Cables to Modular RAID card connectors or PCIe Interposer* E1 E2 E3 F1 F2 F3 Chan E Chan F G1G2 G3 H1H2 H3 Chan G Chan H. SAS x4 SAS/SATA Intel Wellsburg PCH X4 SAS Connector X4 SAS Connector Cables to modular RAID card connectors SAS/SATA USB Thumbdrive X2 AHCI PCIe DMI2 (x4) Gen2 SD1 SD2 DMI2 Intel Xeon Haswell XP (CPU 1) QPI (9.6 GT) Intel Xeon Haswell XP (CPU 2) Modular RAID Card PCIe x8 Gen 3 BMC PCIe PCIe x16 Gen3 PCIe x8 Gen3 PCIe x8 Gen3 PCIe x8 Gen3 PCIe x8 Gen3 X2 AHCI PCIe x16 Gen3 PCIe x8 Gen3 PCIe x8 Gen3 PCIe x16 Gen3 PCIe x8 Gen3 2-port i350 NIC GbE switch mlom Module (a variety of network cards can be installed here) PCIe Riser 1 (option 1) Slot 2 Slot 1 PCIe Riser 1 (option 2) Slot 3 Slot 2 Slot 1 PCIe Riser 1 (option 3) SATA 1 SATA 2 Slot 2 Slot 1 PCIe Riser 2 Slot 6 Slot 5 Slot 4 Rear Panel USB USB VGA Serial 1 GB-T 1 GB-T 1 GB-T (Mgmt) Network connectors (types vary with mlom module) Cisco tem Block Diagram Four Options for Drive Backplane Gen2 (6 Gb/s) Gen3 (12 Gb/s) USB 3.0 PCIe SD controller SD 3.0 QPI (9.6 GT) Front Panel KVM Connector X2 USB VGA 1 Serial PCIe x8 Gen 3 *For PCIe drives in slots 1 and 2 only PCIe x4 Gen3 PCIe x4 Gen3 PCIe Interposer (optional) X2 mini SAS HD 40

41 SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: CPU1 has channels A, B, C, and D CPU2 has channels E, F, G, and H Each DIMM channel has three slots: slot 1, slot 2, and slot 3. The blue-colored DIMM slots are for slot 1, the black-colored slots for slot 2, and the white slots for slot 3. As an example, DIMM slots A1, B1, C1, and D1 belong to slot 1, while A2, B2, C2, and D2 belong to slot 2. Figure 9 shows how slots and channels are physically laid out on the motherboard. The DIMM slots on the right half of the motherboard (channels A, B, C, and D) are associated with CPU 1, while the DIMM slots on the left half of the motherboard (channels E, F, G, and H) are associated with CPU 2. The slot 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding slot 2 (black) and slot 3 (white) slots. Slot 1 slots (blue) are populated before slot 2 slots (black) and slot 3 (white) slots. Figure 9 Physical Layout of CPU DIMM Channels and Slots 41

42 SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your HX240c Node, consider the following items: Each channel has three DIMM slots (for example, channel A = slots A1, A2, and A3). A channel can operate with one, two, or three DIMMs installed. If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically. Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1 Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2 Fill black slots in the channels third: A3, E3, B3, F3, C3, G3, D3, H3 Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized. Observe the DIMM mixing rules shown in Table 26 Table 26 DIMM Rules for HX240c Nodes DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot 1 DIMM Capacity RDIMM = 16, 32, or 64 GB DIMM Speed 2133-MHz 2 DIMMs in the same channel (for example, A1, A2, and A3) can have different capacities. DIMMs will run at the lowest speed of the DIMMs/CPUs installed For best performance, DIMMs in the same slot (for example, A1, B1, C1, D1) should have the same capacity. DIMMs will run at the lowest speed of the DIMMs/CPUs installed DIMM Type RDIMMs Do not mix DIMM types in a channel Do not mix DIMM types in a slot DIMMs per Channel (DPC) 1 DPC, 2 DPC, or 3 DPC See Table 6 on page 16 for valid RDIMM 1 DPC, 2 DPC, and 3 DPC memory configurations Notes Although different DIMM capacities can exist in the same slot, this will result in less than optimal performance. For optimal performance, all DIMMs in the same slot should be identical. 2. Only 2133-MHz DIMMs are currently available for the HX240c M4 node. 42

43 SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 27. Table 27 DIMM Population Order per CPU DIMMs per CPU Populate CPU 1 Slots Populate CPU 2 Slots 8 A1, B1, C1, D1, A2, B2, C2, D2 12 A1, B1, C1, D1, A2, B2, C2, D2 A3, B3, C3, D3 E1, F1, G1, H1, E2, F2, G2, H2 E1, F1, G1, H1, E2, F2, G2, H2 E3, F3, G3, H3 43

44 SUPPLEMENTAL MATERIAL Serial Port Details The pinout details of the rear RJ-45 serial port connector are shown in Figure 10. Figure 10 Serial Port (Female RJ-45 Connector) Pinout Serial Port (RJ-45 Female Connector) Pin Signal RTS (Request to Send) DTR (Data Terminal Ready) TxD (Transmit Data) GND (Signal Ground) GND (Signal Ground) RxD (Receive Data) DSR (Data Set Ready) CTS (Clear to Send) 44

45 SUPPLEMENTAL MATERIAL Upgrade and Servicing-Related Parts This section lists the upgrade and servicing-related parts you may need during the life of your HX240c Node. Some of these parts are configured with every system, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See Table 28. Table 28 Upgrade and Servicing-related Parts for HX240c M4 Node Spare Product ID (PID) Description UCSC-PCIF-01F= PCIe Full Height blanking panel 1 UCSC-PCIF-C240M4= PCIe Riser Blanking Panel 1 UCSC-PCI-2-C240M4= PCIe Riser 2 Assembly 1 UCSC-PCI-1A-240M4= PCIe Riser 1 Assembly UCSC-PCI-1B-240M4= PCIe Riser 1 Assembly (3 x8 slots) 1 UCSC-PCI-1C-240M4= UCSC-MLOM-BLK= M4 PCIe Riser 1 Assembly MLOM Blanking Panel UCSC-HS-C240M3= Heat Sink 1 UCS-CPU-LPCVR= CPU load plate dust cover (for unpopulated CPU sockets) N20-MBLIBATT= Replacement Lithium Battery for motherboard (CR2032) 1 UCSC-FAN-C240M4= UCSC-BAFF-C240M4= Fan Module (one) Air Baffle Replacement Kit UCSC-PSU-BLKP240= Power Supply Blanking Panel 1 UCSC-RAILB-M4= UCSC-CMAB-M4= UCS-SD-64G-S= N20-BKVM= Tool-Less Ball Bearing Rail Kit Reversible CMA for ball bearing rail kit 64 GB SD Card KVM local IO cable for console port UCS-CPU-GREASE3= CPU thermal grease syringe - needed for heatsink seal 2 UCSX-HSCK= UCS Processor Heat Sink Cleaning Kit (when replacing a CPU) 3 Notes This part is included/configured with your HX240c M4 Node (in some cases, as determined by the configuration of your node). 2. This part should be ordered with the purchase of each optional or spare Intel Xeon E v3 or v4 CPU processor kit 45

46 SUPPLEMENTAL MATERIAL Adding an Additional CPU (with CPU heat sink) or Replacing CPUs All Cisco UCS two CPU socket-capable systems can be upgraded from having one to having two CPUs configured or can also support replacement of the CPUs. You will need to order and install a heat sink when adding any additional CPU to a system. Instructions for installing the new CPU or replacing CPUs and heat sink can be found at the following link: NOTE: Unlike previous generation systems, the HX240c M4 Node has tool-less CPU sockets, so no separate tools (such as pick n place tools) are required to add or replace CPUs. See the section titled Replacing CPUs and Heatsinks. Motherboard Lithium Battery You can order a replacement motherboard battery. Installation instructions are found at this link: See the section titled Replacing the Motherboard RTC Battery. Thermal Grease (with syringe applicator) for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink (a grease syringe also ships with each CPU spare option kit). Instructions for applying thermal grease are found at: See the section titled Replacing CPUs and Heatsinks. CAUTION: Use only the thermal grease specified for this system (UCS-CPU-GREASE3=). This thermal grease comes in a white-tipped syringe and is to be used only in the HX220c M4 and HX240c M4 Nodes. Other systems use thermal grease in a blue-tipped syringe (UCS-CPU-GREASE=). Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the HX220c M4 or HX240c M4 Nodes. DO NOT use thermal grease available for purchase at any commercial electronics store. If these instructions are not followed, the CPU may overheat and be destroyed. 46

47 SUPPLEMENTAL MATERIAL NOTE: When you purchase a spare CPU, the thermal grease with syringe applicator is included. Air Baffle Replacement Kit Air baffles are designed to direct airflow through the system to maintain the temperature at a safe operating level. These baffles must always remain installed during operation. The Air Baffle Replacement Kit includes the air baffles needed for one HX240c M4 node. CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link: See the section titled Replacing CPUs and Heatsinks. NOTE: When you purchase a spare CPU, the CPU cleaning kit is included. 47

48 SUPPLEMENTAL MATERIAL Riser Card Configuration and Options The riser card 2 slot assignments are fixed and are shown in Table 29. Table 29 Riser Card 2 Slots Slot # Height Length Electrical Mechanical NCSI Physical Riser Card 2 Slot 6 Slot 5 Slot 4 6 Full Full x8 x16 No 5 Full Full 1 x16 x24 Yes 2 4 Full 3/4 x8 x24 Yes 2 Notes GPU capable slot 2. NCSI supported in only one slot at a time (default slot 5). If a GPU card is present in slot 5, NCSI support automatically moves to slot 4. 48

49 SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 11 on page 50) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: Cisco UCS B-Series servers and fabric interconnects Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 30. Table 30 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) Dimensions (H x W x D) with packaging x 24 x in. (2000 x 610 x 1102 mm) 89 x 33 x 47 in. (2261 x 838 x 1194 mm) x x in. (2000 x 599 x 1102 mm) 89 x 33 x 47 in. (2261 x 838 x 1194 mm) Distance from front mounting rail to rear mounting rail 29.2 in (741 mm) 29.2 in (741 mm) Weight lb (136 kg) lb (105 kg) Weight with packaging 354 lb (161 kg) 284 lb (129 kg) Side panels included Yes No Equipment mounting capacity Static load capacity 42RU 2100 lb (954 kg) 42RU 2100 lb (954 kg) Dynamic load capacity Not applicable Not applicable NOTE: The AC input connector is an IEC 320 C A/250 VAC power inlet. 49

50 SUPPLEMENTAL MATERIAL Figure 11 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed 50

Cisco HyperFlex HX220c M4 Node

Cisco HyperFlex HX220c M4 Node Data Sheet Cisco HyperFlex HX220c M4 Node A New Generation of Hyperconverged Systems To keep pace with the market, you need systems that support rapid, agile development processes. Cisco HyperFlex Systems

More information

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV C.19 JANUARY 22, 2016 WWW.CISCO.COM

More information

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs. , on page 1 External Features, on page 2 Serviceable Component Locations, on page 6 Summary of Server Features, on page 9 The server is orderable in different versions, each with a different front panel/drive-backplane

More information

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter , on page External Features, on page Serviceable Component Locations, on page Summary of Server Features, on page The server is orderable in different versions, each with a different front panel/drive-backplane

More information

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Data Sheet Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Fast and Flexible Hyperconverged Systems You need systems that can adapt to match the speed of your business. Cisco HyperFlex Systems

More information

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Data Sheet Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Fast and Flexible Hyperconverged Systems You need systems that can adapt to match the speed of your business. Cisco HyperFlex Systems

More information

Cisco UCS C24 M3 High-Density Small Form Factor Rack-Mount Server

Cisco UCS C24 M3 High-Density Small Form Factor Rack-Mount Server This product has been discontinued Spec Sheet Cisco UCS C24 M3 High-Density Small Form Factor Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.13 MARCH

More information

Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model) Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.17 JANUARY 13, 2015 WWW.CISCO.COM

More information

Cisco HyperFlex HX220c Edge M5

Cisco HyperFlex HX220c Edge M5 Data Sheet Cisco HyperFlex HX220c Edge M5 Hyperconvergence engineered on the fifth-generation Cisco UCS platform Rich digital experiences need always-on, local, high-performance computing that is close

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Cisco UCS B200 M3 Blade Server

Cisco UCS B200 M3 Blade Server Spec Sheet Cisco UCS B200 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.9 JUNE 7, 2013 WWW.CISCO.COM OVERVIEW...............................................

More information

Cisco UCS Integrated Infrastructure for Big Data and Analytics

Cisco UCS Integrated Infrastructure for Big Data and Analytics Scale Factor Cisco UCS Integrated Infrastructure Total System Cost TPCx-HS Performance Metric /Performance 386,270 USD Apache Hadoop Compatible Software MapR Converged Community Edition, Version 5.0 10.12

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Cisco UCS Integrated Infrastructure for Big Data

Cisco UCS Integrated Infrastructure for Big Data Scale Factor Cisco UCS Integrated Infrastructure Total System Cost TPCx-HS Performance Metric /Performance 842,308 USD Apache Hadoop Compatible Software IBM Open Platform (IBM IOP) 4.1 22.26 HSph@ 37,839.54

More information

Cisco UCS B22 M3 Blade Server

Cisco UCS B22 M3 Blade Server Spec Sheet Cisco UCS B22 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.5 FEBRUARY 14, 2013 WWW.CISCO.COM OVERVIEW...............................................

More information

Compute Cartridges for Cisco UCS M-Series Modular Servers

Compute Cartridges for Cisco UCS M-Series Modular Servers Spec Sheet Compute Cartridges for Cisco UCS M-Series Modular Servers CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.2 AUGUST 11, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments. The IBM System x3500 M4 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or

More information

NEC Express5800/R120h-2E System Configuration Guide

NEC Express5800/R120h-2E System Configuration Guide NEC Express5800/R120h-2E System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Cisco UCS Integrated Infrastructure for Big Data (Cisco UCS CPA v3)

Cisco UCS Integrated Infrastructure for Big Data (Cisco UCS CPA v3) Scale Factor Cisco UCS Integrated Infrastructure Total System Cost TPCx-HS Performance Metric /Performance 518,063 USD Apache Hadoop Compatible Software Cloudera Distribution for Apache Hadoop (CDH) 5.3.2

More information

Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)

Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) This product has been discontinued Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134

More information

Cisco UCS Integrated Infrastructure for Big Data

Cisco UCS Integrated Infrastructure for Big Data Scale Factor Cisco UCS Integrated Infrastructure Total System Cost TPCx-HS Performance Metric /Performance 861,868 USD Apache Hadoop Compatible Software Cloudera Distribution for Apache Hadoop (CDH) 5.3.2

More information

Cisco UCS Integrated Infrastructure for Big Data and Analytics

Cisco UCS Integrated Infrastructure for Big Data and Analytics 30 Total System Cost TPCx-HS Performance Metric /Performance 656,096 USD Apache Hadoop Compatible Software Cloudera Enterprise Edition V5.13.0 11.54 HSph@30TB 56,854.08 USD $/HSph@30TB Operating System

More information

Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model)

Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model) Spec Sheet Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 MARCH 27, 2013 WWW.CISCO.COM

More information

NEC Express5800/R120h-1M System Configuration Guide

NEC Express5800/R120h-1M System Configuration Guide NEC Express5800/R120h-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Cisco UCS C3260 Rack Server

Cisco UCS C3260 Rack Server Spec Sheet Cisco UCS C3260 Rack Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 AUGUST 12, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV A.16 OCTOBER 9, 2012 WWW.CISCO.COM CONTENTS

More information

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/R120d-2M Configuration Guide NEC Express5800/R120d-2M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

HostEngine 5URP24 Computer User Guide

HostEngine 5URP24 Computer User Guide HostEngine 5URP24 Computer User Guide Front and Rear View HostEngine 5URP24 (HE5URP24) computer features Intel Xeon Scalable (Skylake FCLGA3647 socket) Series dual processors with the Intel C621 chipset.

More information

Cisco UCS C240 M3 Server

Cisco UCS C240 M3 Server Data Sheet Cisco UCS C240 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking

More information

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v3 CPU)

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v3 CPU) This product has been discontinued Spec Sheet Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v3 CPU) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.19 June 19, 2017

More information

Cisco UCS C240 M3 Server

Cisco UCS C240 M3 Server Data Sheet Cisco UCS C240 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking

More information

SMF PaaS 27 Engine Feature SMF PaaS 30 Capacity Back Up Enablement ziip Engine Feature 1 Per Engine Per Month $200.

SMF PaaS 27 Engine Feature SMF PaaS 30 Capacity Back Up Enablement ziip Engine Feature 1 Per Engine Per Month $200. SIN Sirius Part Number Description Qty Unit of Measure UMC IBM Mainframe Systems 132 52 SMF PaaS 1 Tier One MIPS (0 99) 1 Per Installed MIP Per Month $64.18 132 52 SMF PaaS 2 Tier Two MIPS (100 800) 1

More information

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Altos R320 F3 Specifications. Product overview. Product views. Internal view Product overview The Altos R320 F3 single-socket 1U rack server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities effectively handle SMB

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Cisco UCS C24 M3 Server

Cisco UCS C24 M3 Server Data Sheet Cisco UCS C24 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking

More information

Flexible General-Purpose Server Board in a Standard Form Factor

Flexible General-Purpose Server Board in a Standard Form Factor Product brief Small and Medium Business, Storage, Networking, Web Hosting, and Security Appliances Intel Server Board S2600ST Product Family Featuring the Intel Xeon Processor Scalable Family Flexible

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Cisco UCS C260 M2 High-Performance Rack-Mount Server

Cisco UCS C260 M2 High-Performance Rack-Mount Server Spec Sheet Cisco UCS C260 M2 High-Performance Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV B.2 NOVEMBER 15, 2013 WWW.CISCO.COM OVERVIEW...............................................

More information

Cisco UCS C3160 Rack Server

Cisco UCS C3160 Rack Server Spec Sheet Cisco UCS C3160 Rack Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 SEPTEMBER 25, 2014 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco UCS B260 M4 Blade Server (with Intel Xeon E7 v3 CPU)

Cisco UCS B260 M4 Blade Server (with Intel Xeon E7 v3 CPU) Spec Sheet Cisco UCS B260 M4 Blade Server (with Intel Xeon E7 v3 CPU) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.21 June 19, 2017 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks enabling easy collaboration

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

PRIMERGY BX2580 M2. System configurator and order-information guide. PRIMERGY Server. Contents. Instructions Configuration diagram Configurator

PRIMERGY BX2580 M2. System configurator and order-information guide. PRIMERGY Server. Contents. Instructions Configuration diagram Configurator PRIMERGY BX2580 M2 System configurator and order-information guide Contents Instructions Configuration diagram Configurator # X BX2580 Dual Socket 20 # XI Processor 21 # XII Storage # XIII Memory # XIV

More information

Cisco UCS B420 M3 Blade Server

Cisco UCS B420 M3 Blade Server Cisco UCS B420 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.12 AUGUST 22, 2014 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Milestone Definition Date. The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public.

Milestone Definition Date. The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public. Product End-of-Life Notice End-of-Sale and End-of-Life Announcement for the Legacy Fixed-Configuration s for Cisco Unified Communications on Cisco UCS B200, C210, and C200 M2 Servers EOL8229 Cisco announces

More information

Cisco UCS B420 M3 Blade Server

Cisco UCS B420 M3 Blade Server This product has been discontinued Cisco UCS B420 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV C.10 DECEMBER 13, 2016 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

NEC Express5800/R120h-1E System Configuration Guide

NEC Express5800/R120h-1E System Configuration Guide NEC Express5800/R120h-1E System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini White Paper Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini February 2015 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 9 Contents

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Cisco UCS B200 M4 Blade Server

Cisco UCS B200 M4 Blade Server Spec Sheet Cisco UCS B200 M4 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.4 OCTOBER 31, 2014 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 17 Sas Expander

More information

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server Cisco UCS C210 M2 General-Purpose Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total

More information

Density Optimized System Enabling Next-Gen Performance

Density Optimized System Enabling Next-Gen Performance Product brief High Performance Computing (HPC) and Hyper-Converged Infrastructure (HCI) Intel Server Board S2600BP Product Family Featuring the Intel Xeon Processor Scalable Family Density Optimized System

More information

NEC Express5800/R120h-1E System Configuration Guide

NEC Express5800/R120h-1E System Configuration Guide NEC Express5800/R120h-1E System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Cisco UCS C260 M2 High-Performance Rack-Mount Server

Cisco UCS C260 M2 High-Performance Rack-Mount Server Spec Sheet Cisco UCS C260 M2 High-Performance Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.3 DECEMBER 2, 2011 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v4 CPU)

Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v4 CPU) Spec Sheet Cisco UCS B460 M4 Blade Server (with Intel Xeon E7 v4 CPU) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.9 August 31, 2017 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

NEC Express5800/D120h System Configuration Guide

NEC Express5800/D120h System Configuration Guide NEC Express5800/D120h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Altos T310 F3 Specifications

Altos T310 F3 Specifications Product overview The Altos T310 F3 delivers proactive management tools matched by best priceperformance technology ideal for SMB and branch office operations. This singlesocket tower server features an

More information

Cisco Content Delivery Engine 285 for Open Media Distribution

Cisco Content Delivery Engine 285 for Open Media Distribution Data Sheet Cisco Content Delivery Engine 285 for Open Media Distribution Cisco Content Delivery Engines (CDEs) are carrier-class appliances that power Cisco s CDN software for Internet video streaming.

More information

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server Spec Sheet Cisco UCS C210 M2 General-Purpose Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.3 DECEMBER 2, 2011 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini White Paper Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini June 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 9 Contents

More information

Cisco UCS B200 M2 Blade Server

Cisco UCS B200 M2 Blade Server SpecSheet Cisco UCS B200 M2 Blade Server Overview The Cisco UCS B200 M2 Blade Server is a two-socket, half-width blade server, using Intel s Xeon 5500 and 5600 Series processors with 12 DIMM slots, one

More information

Cisco UCS B22 M3 Blade Server

Cisco UCS B22 M3 Blade Server This product has been discontinued Spec Sheet Cisco UCS B22 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.8 MAY 9, 2015 WWW.CISCO.COM OVERVIEW...............................................

More information

Server Specifications

Server Specifications , page 1 Power Cord s, page 6 This appendix lists the physical, environmental, and power specifications for the server. Physical s, on page 1 Environmental s, on page 2 Power s, on page 2 Physical s The

More information

HP ProLiant DL360 G7 Server - Overview

HP ProLiant DL360 G7 Server - Overview Menu Hewlett Packard Enterprise Support Center Search Notifications Help Settings HP ProLiant DL360 G7 Server - Overview Product description What's new Product features Software overview Important links

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

Cisco Content Delivery Engine 280 for TV Streaming

Cisco Content Delivery Engine 280 for TV Streaming Data Sheet Cisco Content Delivery Engine 280 for TV Streaming Cisco Content Delivery Engines (CDEs) are carrier-class appliances that power the Videoscape Distribution Suite (VDS) software for TV video

More information

Cisco UCS C240 M5 Server Installation and Service Guide

Cisco UCS C240 M5 Server Installation and Service Guide First Published: 2017-07-14 Last Modified: 2018-05-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

Part Number Unit Descriptions

Part Number Unit Descriptions Part Number Unit Descriptions 2582B2A System x3100m4 Simple Swap (SATA) Xeon 4C E3-1220v2 69W 3.1GHz/1600MHz/8MB Form factor Tower (can be a 4U rack form factor using the optional Tower-to-Rack Conversion

More information

Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture

Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture WHITE PAPER Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture Based on the SQL Server 2016 Data Warehouse Fast Track

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

Servicing a Blade Server

Servicing a Blade Server This chapter contains the following sections: Replacing a Drive, page 1 Removing a Blade Server Cover, page 4 Air Baffles, page 5 Internal Components, page 6 Diagnostics Button and LEDs, page 7 Installing

More information

Cisco MCS 7825-I1 Unified CallManager Appliance

Cisco MCS 7825-I1 Unified CallManager Appliance Data Sheet Cisco MCS 7825-I1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture

Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture WHITE PAPER Cisco UCS C240 M4 Rack Server with Lightning Ascend Gen. II SAS SSDs from SanDisk 36TB Data Warehouse Fast Track Reference Architecture Based on the SQL Server 2014 Data Warehouse Fast Track

More information

Cisco UCS B440 M2 Blade Server

Cisco UCS B440 M2 Blade Server This product has been discontinued Spec Sheet Cisco UCS B440 M2 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.9 MAY 20, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................

More information

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Cisco UCS C210 M1 General-Purpose Rack-Mount Server Cisco UCS C210 M1 General-Purpose Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total

More information

QuickSpecs. HPE Cloudline CL7100 Server. Overview

QuickSpecs. HPE Cloudline CL7100 Server. Overview Overview The is Open Compute Compliant and is designed for service providers that need very high density compute platforms for Open Rack deployment. The CL7100 is based upon the OCPv1 (Open Compute Project)

More information

Cisco UCS B230 M1 Blade Server

Cisco UCS B230 M1 Blade Server This Product Has Been Discontinued SpecSheet Cisco UCS B230 M1 Blade Server Overview The Cisco UCS B230 M1 Blade Server is a two-socket, half-width blade server, using Intel s Xeon 6500 and 7500 Series

More information

Cisco UCS B460 M4 Blade Server

Cisco UCS B460 M4 Blade Server Data Sheet Cisco UCS B460 M4 Blade Server Product Overview The new Cisco UCS B460 M4 Blade Server uses the power of the latest Intel Xeon processor E7 v3 product family to add new levels of performance

More information

Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco UCS C200 M2 High-Density Rack-Mount Server Cisco UCS C200 M2 High-Density Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total cost

More information

Cisco UCS B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server Data Sheet Cisco UCS B230 M2 Blade Server Product Overview The Cisco UCS B230 M2 Blade Server is one of the industry s highest-density two-socket blade server platforms. It is a critical new building block

More information

Full Featured with Maximum Flexibility for Expansion

Full Featured with Maximum Flexibility for Expansion PRODUCT brief Data Center, Cloud, High Performance Computing Intel Server Board S2600WF Product Family Featuring the 2 nd Generation Intel Xeon Processor Scalable Family Full Featured with Maximum Flexibility

More information

Acer AW2000h w/aw170h F2 Specifications

Acer AW2000h w/aw170h F2 Specifications Product overview The Acer AW2000h w/aw170h F2 provides first-class performance, innovative technology, high configurability, and comprehensive management features. The 2U rack-mountable form factor saves

More information

Intel Select Solutions for Professional Visualization with Advantech Servers & Appliances

Intel Select Solutions for Professional Visualization with Advantech Servers & Appliances Solution Brief Intel Select Solution for Professional Visualization Intel Xeon Processor Scalable Family Powered by Intel Rendering Framework Intel Select Solutions for Professional Visualization with

More information

SmartPlay Select. Cisco Global Data Center Sales. Haresh Kripalani UCS Product Management. Jonathan Ralph Global Data Center Sales April 6, 2015

SmartPlay Select. Cisco Global Data Center Sales. Haresh Kripalani UCS Product Management. Jonathan Ralph Global Data Center Sales April 6, 2015 SmartPlay Select Cisco Global Data Center Sales Jonathan Ralph Global Data Center Sales April 6, 2015 Haresh Kripalani UCS Product Management Quick Links Guide Quick Program Guide Links Useful Links Outside

More information

Cisco UCS E-Series Servers

Cisco UCS E-Series Servers Data Sheet Cisco UCS E-Series Servers Product Overview Cisco UCS E-Series Servers, part of the Cisco Unified Computing System (Cisco UCS), are next-generation power-optimized general-purpose x86 64-bit

More information

Capacity driven storage server. Capacity driven storage server

Capacity driven storage server. Capacity driven storage server Capacity driven storage server Be ready for the era of big data? ASUS, as always, make servers in keeping with the market trend and deliver superior performance. To meet up with the big data demand, the

More information

NEC Express5800/R120e-2E Configuration Guide

NEC Express5800/R120e-2E Configuration Guide NEC Express5800/R120e-2E Configuration Guide Standard model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure

More information

Cisco UCS B200 M3 Blade Server

Cisco UCS B200 M3 Blade Server Data Sheet Cisco UCS B200 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C- Series Rack Servers with networking and storage

More information

Cisco UCS Mini. Report Date: November 20, 2017 Total System Cost TPCx-IoT Performance Metric Price/Performance 142, IoTps

Cisco UCS Mini. Report Date: November 20, 2017 Total System Cost TPCx-IoT Performance Metric Price/Performance 142, IoTps Cisco UCS Mini Total System Cost TPCx-IoT Performance Metric Price/Performance 133,662 USD 142,493.85 IoTps 0.94 USD $/IoTps DBMS Software 300 Million HBase 1.2.1 On Cloudera Distribution for Apache Hadoop

More information

Cisco UCS B440 M1High-Performance Blade Server

Cisco UCS B440 M1High-Performance Blade Server Cisco UCS B440 M1 High-Performance Blade Server Product Overview The Cisco UCS B440 M1 High-Performance Blade Server delivers the performance and reliability to power compute-intensive, enterprise-critical

More information

Change Log. 05/16/2014 Original release 2014 LENOVO. ALL RIGHTS RESERVED.

Change Log. 05/16/2014 Original release 2014 LENOVO. ALL RIGHTS RESERVED. Change Log Version Change 05/16/2014 Original release 2 Overview Product Features RS140 Technical Summary Operating System Support Mechanicals Front View Mechanicals / HDD Configurations Rear View Under

More information

GW2000h w/gw175h/q F1 specifications

GW2000h w/gw175h/q F1 specifications Product overview The Gateway GW2000h w/ GW175h/q F1 maximizes computing power and thermal control with up to four hot-pluggable nodes in a space-saving 2U form factor. Offering first-class performance,

More information

ThinkServer RD450 Platform Specifications

ThinkServer RD450 Platform Specifications ThinkServer RD450 Platform Specifications Components Dimensions Weight Processor RAID controller Specification 2U rack. Height: 87 mm (3.4 in), width: 482 mm (19 in), depth: 764 mm (30 in) Minimum configuration:

More information

Cisco UCS C24 M3 High-Density Large Form Factor Rack-Mount Server

Cisco UCS C24 M3 High-Density Large Form Factor Rack-Mount Server This product has been discontinued Spec Sheet Cisco UCS C24 M3 High-Density Large Form Factor Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.10 MARCH

More information

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Datasheet for Red Hat certification Standard server node for PRIMERGY

More information

HostEngine 3U Host Computer User Guide

HostEngine 3U Host Computer User Guide HostEngine 3U computer features Intel Xeon 3.2GHz or lower-speed single- or dual-processor(s) with the Intel C602 chipset. HostEngine 3U provides four PCI Express (PCIe) Gen 3.0 x16 expansion slots. Each

More information

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER Contract title : Supply of Information & Communication Technology Hardware Publication reference: 2017/386304 10/1/1.1/1.2.2a p 1 / Columns 1-2

More information

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server White Paper Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server Executive Summary This document describes the network I/O performance characteristics of the Cisco UCS S3260 Storage

More information

Cisco UCS C220 M5 Server Installation and Service Guide

Cisco UCS C220 M5 Server Installation and Service Guide First Published: 2017-07-14 Last Modified: 2018-03-19 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information