Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Size: px
Start display at page:

Download "Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications"

Transcription

1 DATA SHEET Advanced enset Controller, 200 Operation modes Display and unit front eneral Engine control M-Logic Optional applications DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax: Document no.: L SW version: 4.2x.x or later

2 200 data sheet UK 1. Application information 1.1. eneral information Application Description Application emulation Single-line diagrams Single-line application diagrams Optional power management applications Standard functions 2.1. Comparison Chart Comparisons Protections Set-up M-Logic Available variants Available options Available accessories Functional block diagram 3.1. Functional block diagram Automatic mains failure/mains power export/peak shaving/load takeover Single generator/load sharing/power management Displays 4.1. Display layouts Display layout - 213, 233, Display layout - 212, 222, 232, Display layout Display layout Display layout Rear side view Technical specifications 5.1. Technical specifications table Unit dimensions 6.1. Unit dimensions in mm (inches) Ordering information 7.1. Order specifications and disclaimer Variants Example Accessories Example: Disclaimer...32 DEIF A/S Page 2 of 32

3 200 data sheet UK Application information 1. Application information 1.1 eneral information Application The Automatic enset Controller,, is a control unit containing all necessary functions for protection and control of a genset. It can be used as a single unit for one genset, or a number of s can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains. The contains all necessary 3-phase measuring circuits, and all values and alarms are presented on the display. The is a compact all-in-one unit designed for the following applications: Standard plant modes Island mode Automatic Failure Fixed power Peak shaving Load takeover power export Applications Power plant with synchronising generators or a stand-alone generator. Can also be used in critical power plants. Critical power/emergency standby plants, black start generator. Power plant with fixed kw setpoint (including building load). Power plant where generator supplies peak load demand paralleled to the mains. Plant mode where the load is moved from mains to generator, e.g. peak demand periods or periods with risk of power outages. Power plant with fixed kw setpoint (excluding building load). The plant modes are configurable, and it is possible to change the plant mode on the fly both in single and in power management applications. All modes can be combined with Automatic Failure mode (AMF). The plant/genset is easily controlled from the display, or an HMI/scada system can be implemented using one of the communication options. Three display units can be installed per control unit Description 200 variants equipped with power management are able to handle simple or advanced applications for a great number of power plant projects within synchronising gensets, critical power/emergency standby applications or power producing applications. The following number of units can be controlled in a power management system: 16 mains feeders with mains and tie 8 bus tie s on the generator bus or load bus 16 generators with generator s The complete power management system can easily be monitored from the PC utility SW through a graphical supervision page. Running status, hours in operation, status, condition of mains and busbars and fuel consumption are just some of the values that are presented. DEIF A/S Page 3 of 32

4 200 data sheet UK Application information Application emulation In order to verify and test the functionality of the application, it is possible to use the emulation tool of the. Being connected to the gives the possibility to test a majority of the functionality, e.g. plant modes and logics, handling, mains and generator operation. Application emulation is useful for training, customising plant requirements and testing basic functionality that needs to be set up or verified. In a power management system it is possible to control the entire plant, being connected only to one of the connected controllers. 1.2 Single-line diagrams Single-line application diagrams 212/222 Island Busbar 213 failure. With separate transducer: Peak shaving, load takeover and mains power export 233/243 failure, peak shaving, load takeover and mains power export enerator (B) 200 (MB) 200 (MB) 200 Load Load enerator (B) enerator (B) Diesel generator set Diesel generator set Diesel generator set 222/232/242 Multiple gensets, load sharing, up to 128 generators (CANshare) 242 (222/243)/244 Island power management, up to 16 generators, up to 8 bus tie s Busbar CANbus Busbar CANbus enerator (B 1) enerator (B 2) enerator (B 1) enerator (B 2) Diesel generator set 1 Diesel generator set 2 Diesel generator set 1 Diesel generator set 2 DEIF A/S Page 4 of 32

5 200 data sheet UK Application information 242(222/243)/244/245 Up to 16 mains, 16 generators load sharing and up to 8 bus tie s 17 (MB 17) 245 BTB 33 Busbar CANbus enerator (B 1) 242 enerator (B 2) Diesel generator set 1 Diesel generator set 2 DEIF A/S Page 5 of 32

6 200 data sheet UK Application information 242(222/243)/244/246 Up to 16 mains with tie s, 16 generators load sharing and up to 8 bus tie s 17 (MB 17) 246 Load Tie (TB 17) BTB 33 Busbar CANbus enerator (B 1) enerator (B 2) Diesel generator set 1 Diesel generator set 2 DEIF A/S Page 6 of 32

7 200 data sheet UK Application information Optional power management applications Main - tie - main application. Ring bus may be used depending on applicational needs Consumers Consumers Consumers Consumers Tie 3 Tie 4 Bus tie 1 Bus tie 2 Bus tie 3 Bus tie 4 CANbus CANbus Diesel generator set 1 H-coupling. The tie controlled by the 200 mains is selectable depending on applicational needs. The bus tie can be present without an 200 controller (open/closed feedbacks are needed) (MB 17) 200 (MB 18) 200 Consumers Consumers Tie (TB 17) Tie TB 18) BTB 33 Busbar CANbus BUSBAR CANBUS enerator (B 1) enerator enerator enerator (B 2) (B 3) (B 4) Diesel generator set 1 Diesel generator set 2 Diesel generator set 3 Diesel generator set 4 X mains and 1 D. The tie controlled by the 200 mains is selectable depending on applicational needs. DEIF A/S Page 7 of 32

8 200 data sheet UK Application information (MB 17) (MB 18) (MB 19) (MB 20) Consumers Consumers Consumers Consumers Consumers Tie (TB 17) Tie (TB 18) Tie (TB 19) Tie (TB 20) Tie (TB 21) Busbar CANbus enerator (B 1) 200 Diesel generator set 1 DEIF A/S Page 8 of 32

9 200 data sheet UK Standard functions 2. Standard functions 2.1 Comparison Chart Comparisons Model Measuring enerator/busbar voltage (3-phase/ 4-wire) enerator current (3 x true r.m.s.) Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ CT selectable 1/5 Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ 100 to 690V AC selectable /busbar voltage (3-phase/4- wire) current or neutral current (1 x true r.m.s.) or ground current with 3rd harmonic filter Selectable AC configuration 3-phase/3-wire 3-phase/4-wire 2-phase/3-wire L1L3 (180º between phases) 2-phase/3-wire L1L2 (120º between phases) 1-phase/2-wire L1 Phase angle compensation gen/ busbar/mains synchronising over a D/Y transformer Single genset enset modes Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ 246 Χ Χ Χ Χ Χ Χ Χ X X X X X X X X X X Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Island operation Χ Χ Χ Χ Χ Χ Χ DEIF A/S Page 9 of 32

10 200 data sheet UK Standard functions Model Fixed power/base load AMF & ATS (auto mains failure operation) Χ Χ Χ Χ Χ Χ Peak shaving Χ Χ Χ Load takeover Χ Χ Χ power export Χ Χ Χ AMF mode Χ Χ Χ Multi-genset Power management plant mode Island operation Χ Χ Χ Fixed power/base load Χ Χ Χ Χ Χ Peak shaving Χ Χ Χ Χ Χ Load takeover Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ AMF mode Χ Χ Χ Χ Χ eneral Status relay Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ 16A crank and run relay Χ Χ Χ Χ Χ Χ Χ Lamp test Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ USB interface to PC power export Temperature-dependent coolingdown Time-based cooling-down Emergency cooling-down Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ X X X X X X X DEIF A/S Page 10 of 32

11 200 data sheet UK Standard functions Model kwh meter Produced kwh meter day Produced kwh meter week Produced kwh meter year Produced kwh meter total Operation hours and emergency hours counter B and MB operation counter Start attempt counter Maintenance counters, hours and days Free PC utility software for commissioning Control Start/stop sequences Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ X Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Synchronisation Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Nos. of s/ contactors to be controlled /2 1/ Run coil Χ Χ Χ Χ Χ Χ Χ Stop coil with wire break supervision J1939 regulation governor/avr Relay outputs for governor control/ AVR Analogue outputs for governor control/avr Digital load sharing (CAN share), with first up discrimination Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ IOM 220 IOM 220 IOM 220 IOM 220 IOM 220 IOM 220 IOM 220 X Χ Χ Χ Χ 246 DEIF A/S Page 11 of 32

12 200 data sheet UK Standard functions Model Use CAN share when PMS is down Analogue load sharing Event LO with real-time clock Alarm LO with real-time clock Battery test LO with real-time clock Engine diagnostic active alarm LO Engine diagnostic historical alarm LO I/Os Inputs (configurable) Relay outputs (configurable) Multi-inputs (configurable) 212 IOM IOM X X X IOM 230 IOM 230 IOM 230 IOM 230 IOM Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Emergency input Pick-up MPU/W/ PNP/NPN/tacho D+ alternator field flash circuit CANbus communication interfaces RS485/Modbus RTU slave interface(s) TCP/IP Modbus communication Χ Χ Χ Χ Χ Χ Χ SD card USB 2.0 service port M-Logic Simple logic configuration tool Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ 246 DEIF A/S Page 12 of 32

13 200 data sheet UK Standard functions Model Selectable input events Selectable output commands Power management functions Load-dependent start/stop Priority selection Manual Running hours Fuel optimisation round relay control Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ ATS control Χ Χ Χ Safety stop (fail class = trip and stop) Χ Χ Χ Load management Χ Χ Χ Χ Χ Secured mode Χ Χ Χ Quick setup/broadcast 246 Χ Χ Χ Χ Χ Χ Base load Χ Χ Χ Heavy consumer (HC) Asymmetric load sharing (LS) Common PF control Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ Χ CAN flags Χ Χ Χ Χ Χ Χ DEIF A/S Page 13 of 32

14 200 data sheet UK Standard functions Protections Protection (# alarms) (ANSI) 212/222/232/ /233/243 Reverse power x2 32R Χ Χ Χ Χ Short-circuit x2 50P/N Χ Χ Χ Χ Overcurrent x4 51 Χ Χ Χ Χ Voltage-dependent overcurrent x1 51V Χ Χ Χ Χ Overvoltage x2 59P Χ Χ Χ Χ Undervoltage x3 27P Χ Χ Χ Χ Overfrequency x3 81O Χ Χ Χ Χ Underfrequency x3 81R Χ Χ Χ Χ Unbalanced voltage x1 47 Χ Χ Χ Χ Unbalanced current x1 46 Χ Χ Χ Χ Underexcitation or VAr import x1 32RV Χ Χ Χ Χ Overexcitation or VAr export x1 32FV Χ Χ Χ Χ Overload x5 32F Χ Χ Χ Χ Busbar/mains overvoltage x3 59P Χ Χ Χ Χ Busbar/mains undervoltage x4 27P Χ Χ Χ Χ Busbar/mains overfrequency x3 81O Χ Χ Χ Χ Busbar/mains underfrequency x4 81U Χ Χ Χ Χ Busbar/mains unbalanced voltage /246 x1 47 Χ Χ Χ Χ Load shed via current # levels x3 51 Χ Χ Χ Χ Load shed via busbar freq. # levels x3 81 Χ Χ Χ Χ Load shed via overload # levels x3 32 Χ Χ Χ Χ Load shed via fast overload # levels Multi-analogue input 1/with wire break supervision Multi-analogue input 2/with wire break supervision Multi-analogue input 3/with wire break supervision x3 32 Χ Χ Χ Χ x2 NA Χ Χ Χ Χ x2 NA Χ Χ Χ Χ x2 NA Χ Χ Χ Χ Emergency stop x1 1 Χ Χ Χ Χ Overspeed x2 12 Χ Χ Low battery voltage x1 27DC Χ Χ Χ Χ High battery voltage x1 59DC Χ Χ Χ Χ DEIF A/S Page 14 of 32

15 200 data sheet UK Standard functions Protection (# alarms) (ANSI) 212/222/232/ /233/243 enerator external trip x1 5 Χ Χ external trip x1 5 Χ Χ Χ B synchronisation failure x1 25 Χ Χ Χ Χ B open failure x1 52BF Χ Χ Χ Χ B close failure x1 52BF Χ Χ Χ Χ B position failure x1 52BF Χ Χ Χ Χ MB synchronisation failure x1 25 Χ Χ MB open failure x1 52BF Χ Χ MB close failure x1 52BF Χ Χ MB position failure x1 52BF Χ Χ Close before excitation failure x1 48 Χ Χ Phase sequence error x1 47 Χ Χ Χ Χ Deload error x1 34 Χ Χ Χ Χ Crank failure x1 48 Χ Χ Running feedback error x1 34 Χ Χ MPU wire break x1 NA Χ Χ Start failure x1 48 Χ Χ Hz/V failure x1 53 Χ Χ Stop failure x1 48 Χ Χ Stop coil supervision (wire break) x1 5 Χ Χ Engine heater x1 26 Χ Χ Battery test alarm x1 NA Χ Χ Max. ventilation x2 NA Χ Χ Χ Χ Not in Auto x1 34 Χ Χ Χ Χ Fuel fill check error x1 NA Χ Χ EIC warning via J1939/comm. link EIC shutdown via J1939/comm. link EIC coolant temperature via J1939/comm. link EIC oil pressure via J1939/ comm. link EIC oil temperature via J1939/ comm. link x1 NA Χ Χ x1 NA Χ Χ x2 NA Χ Χ x2 NA Χ Χ x2 NA Χ Χ EIC communication error x1 NA Χ Χ /246 DEIF A/S Page 15 of 32

16 200 data sheet UK Standard functions Set-up Set-up is secured by three levels of passwords and is easily done via a menu structure on the display or via a PC and the free Multi-line 2 Windows based PC utility software. The PC utility software can be downloaded free of charge from This utility software allows the operator to monitor all relevant information during commissioning, save and upload/download settings, download software updates and even control the genset either from a USB connection local to the unit or over Ethernet from anywhere in the world M-Logic Customise your control system to your specific needs with this Boolean logic included in the. Control functions can be modified or created based on digital inputs, J1939/comm. link data, analogue inputs, alarms, limits, specific functions or operating conditions. This powerful system configuration tool is included in all systems without additional cost and is programmed by the free PC utility software. 2.2 Available variants Type Variant Description Item no. Note with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM with IOM Available options In order to perfectly match the product solution to specific applications, the functionality of the 200 can be equipped with a number of available options. The options selected by the customer will be integrated in the standard 200, hereby securing the same user interface unaffected by whether the application needs a highly complex or a more basic genset controller. DEIF A/S Page 16 of 32

17 200 data sheet UK Standard functions Option Description ANSI Option Type A A1 Loss of mains protection package Vector jump df/dt (ROCOF) Undervoltage with programmable time delay (6 point curve) Ut < Undervoltage and reactive power, U and Q (78) (81R) (27) (27+32RV) Software A4 Positive sequence (mains) voltage low (27) Software A5 Directional overcurrent (67) Software C C2 H enerator add-on protection package Negative sequence voltage high Negative sequence current high Zero sequence voltage high Zero sequence current high Power-dependent reactive power (12 point true field loss emulating the generator capability curve) IEC/IEEE inverse time overcurrent (curves: 6 fixed, 1 adjustable) Serial communication (47) (46) (59) (50) (40) (51) Software H2 Modbus RTU (RS485) Software I I1 L Application emulation Emulation, PC-controlled emulation of your application Heatfoil for display Software L2 Display -40 C (-40 F) Hardware N Ethernet communication N5 Ethernet TCP/IP Modbus RTU Software T T1 Special applications Critical power, redundant controller, short circuit limitation Software Note Requires software version 4.21 or later Requires software version 4.21 or later and Power management DEIF A/S Page 17 of 32

18 200 data sheet UK Standard functions 2.4 Available accessories Operator panels Accessories Description Item no. Note Additional Operator Panel, AOP-2 (X4) 16 configurable LEDs, 8 configurable buttons and 1 status relay. CANbus comm Five AOP-2 units can be used with each 200 unit Display gasket Display gasket IP Standard is IP52 Cables USB cable, 3 m (J7) For PC utility software Ethernet cable, crossed, 3 m (J4) For option N Documentation Designer s Reference Handbook (K1) CD-ROM with complete documentation (K2) DEIF A/S Page 18 of 32

19 200 data sheet UK Functional block diagram 3. Functional block diagram 3.1 Functional block diagram Automatic mains failure/mains power export/peak shaving/load takeover LOAD 200 AVR control Inputs Outputs CAN interface Neutral en. Voltage en. Current* round current Neutral Voltage Current* Breaker en. Breaker Communication TCP/IP RS485 Modbus CANbus www Additional Operator Panels External I/O Modules SCADA * current and ground current use the same AC current input and can therefore not be mounted simultaneously. They may or may not be used. DEIF A/S Page 19 of 32

20 200 data sheet UK Functional block diagram Single generator/load sharing/power management LOAD 200 AVR control Inputs Outputs CAN interface Neutral en. Voltage en. Current round current* Neutral Busbar Voltage en. Breaker TCP/IP Communication RS485 Modbus CANbus CANbus Load sharing/ Power management www Additional Operator Panels External I/O Modules SCADA *round current may or may not be used. DEIF A/S Page 20 of 32

21 200 data sheet UK Displays 4. Displays 4.1 Display layouts Display layout - 213, 233, Display layout - 212, 222, 232, 242 DEIF A/S Page 21 of 32

22 200 data sheet UK Displays Display layout Display layout DEIF A/S Page 22 of 32

23 200 data sheet UK Displays Display layout DEIF A/S Page 23 of 32

24 200 data sheet UK Displays Rear side view B OFF B ON MB OFF MB ON CONF 34 CONF 32 CONF 30 CONF MULTI INPUT CAN C CAN B CAN A RS MPU W/L RUN CRANK E-STOP COIL STOP - + POWER PREHEAT L1 L2 L3 N D B OFF 90 B ON 89 MB OFF 88 MB ON Available CANbus lines for the different 200 variants. 21x 22x 23x 24x CAN A X X CAN B X X X CAN C (Engine conmmunication) X X X X Terminals and are not available in 21x and 22x. DEIF A/S Page 24 of 32

25 200 data sheet UK Technical specifications 5. Technical specifications 5.1 Technical specifications table Accuracy Class o C Temperature coefficient: +/-0.2% of full scale per 10 o C Short circuit: 5% of 3.5*nominal current Earth current: 2% of 1 A or 5 A To IEC/EN Operating temperature o C ( o F) UL/cUL Listed: Max. ambient temp. 50 o C/122 o F With option L2: o C ( o F) Storage temperature C ( F) Climate 97% RH to IEC Operating altitude Up to 3000 m above sea level Measuring voltage V AC (+20%) UL/cUL Listed: V AC Phase to phase Load: 1.5 MΩ Frequency Measuring current Hz 1 A or 5A AC from current transformer Consumption max.: 0.3 VA/phase UL/cUL Listed: Use listed or R/C (XODW2.8) current transformers Current overload The unit has been tested with the following currents: I n 20 A: 60 sec. I n 100 A: 10 sec. I n 300 A: 1 sec. DEIF A/S Page 25 of 32

26 200 data sheet UK Technical specifications Magnetic pick-up input: Aux. supply Voltage: 2-70 V peak Frequency: Hz Resistance: Ω 6-36V DC continuously UL/cUL Listed: V DC 0V DC for 50 ms when coming from at least 12V DC (cranking dropout) Max. 25 W consumption With option L2-40 o C (-40 o F) Max. 45 W consumption Passive binary input voltage: Emergency stop input voltage: Multi-functional inputs: The aux. supply inputs are to be protected by a 12 A slow-blow fuse Bi-directional optocoupler ON: 8 36V DC <2 V: OFF Impedance: 4.7 kω ON: +8 36V DC (term. 25) <2 V: OFF Impedance: 4.7 kω Current input: 0(4)-20 ma From active transmitter: 0-20 ma, +/-1% Impedance: 50 Ω Binary input: Dry contact inputs 3V DC internal supply, with cable supervision Max. resistance for ON detection: 100 Ω Pt100: o C ( o F) +/-1% To IEC/EN Relay outputs, electrical rating: RMI: Ω, +/-1% Relays and 28-43: 250V AC/30V DC 8 A UL/cUL Listed: 250V AC/30V DC 6 A eneral use B300 Pilot duty Relay 23: 36V DC 8 A UL/cUL Listed: 24V DC 8 A eneral use Relay 26 and 27: 36V DC 16 A UL/cUL Listed: 24V DC 16 A eneral use DEIF A/S Page 26 of 32

27 200 data sheet UK Technical specifications alvanic seperation: 222, , , 246 Between AC voltage and other I/Os: 3250V AC, 50 Hz, 1 minute. Between AC current and other I/Os: 2200V AC, 50 Hz, 1 minute. Between relay outputs and other I/Os: 2200V AC, 50 Hz, 1 minute. Between aux supply and other I/Os: 550V AC, 50 Hz, 1 minute. Between binary input groups and other I/Os: 550V AC, 50 Hz, 1 minute. Between analogue input groups and other I/Os: 550V AC, 50 Hz, 1 minute. The same as above, but with no galvanic separation on analogue input groups. 212, 213 Mounting: Front size: Panel cutout: Display: Safety: Panel-mounted 312 x 219 mm (122.8 x 86.2 in) 297 x 204 mm (11.69 x 8.03 in) Tolerance: +0,4/-0 mm 240 x 128 pixel backlight STN To EN , installation category (overvoltage category) III, 600 V, pollution degree 2 To UL508 and CSA22.2 No Installation category (overvoltage category) III, 600 V, pollution degree 2 Protection: Front: IP52/NEMA type 1 (IP66/NEMA type 1 with gasket, option L1) Terminals: IP20/NEMA type 1 To IEC/EN EMC/CE: To EN /2/3/4 IEC IEC power distr. zone IACS UR E10 power distr. zone Vibration Hz: 2 mm pp Hz: 0.7 g. To IEC and IACS UR E Hz: 0.15mm pp Hz: 1 g. To IEC Response (class 2) Hz: 2 g. To IEC Endurance (class 2) Shock: 10 g, 11 ms, half sine. To IEC Response (class 2) 30 g, 11 ms, half sine. To IEC Endurance (class 2) 50 g, 11 ms, half sine. To IEC Bump 20 g, 16 ms, half sine. To IEC (class 2) Material Plug connections: All plastic materials are self-extinguishing according to UL94 (V1) AC voltage/current inputs: 3.5 mm 2 (13 AW) multi-stranded Other: 1.5 mm 2 (16 AW) multi-stranded Service port: USB A-B TCP/IP: RJ 45 Tightening torque, min.: Approvals: AC voltage input: 0.5 Nm (5-7 lb-in) Other: 0.5 Nm (5-7 lb-in) UL/cUL Listed to UL508 UL/cUL Recognized to UL2200 DEIF A/S Page 27 of 32

28 200 data sheet UK Technical specifications Weight: 200: 1.6 kg (3.5 lbs) Option J6: 0.2 kg (0.4 lbs) AOP-2: 0.4 kg (0.9 lbs) DEIF A/S Page 28 of 32

29 200 data sheet UK Technical specifications Response times: (Delay set to minimum) Busbar: Over-/undervoltage: < 50 ms Over-/underfrequency: < 50 ms enerator: Reverse power: <200 ms Overcurrent: <200 ms Short circuit: < 40 ms Directional overcurrent: <100 ms Over-/undervoltage: <200 ms Over-/underfrequency: <300 ms Overload: <200 ms Current unbalance: <200 ms Voltage unbalance: <200 ms React. power import: <200 ms React. power export: <200 ms Negative sequence I: <400 ms Negative sequence U: <400 ms Zero sequence I: <400 ms Zero sequence U: <400 ms Overspeed: <400 ms Digital inputs: <250 ms Analogue input: <250 ms Emergency stop: <200 ms Earth current: <100 ms : df/dt (ROCOF): <130 ms (4 periods) Vector jump: < 40 ms DEIF A/S Page 29 of 32

30 200 data sheet UK Technical specifications Positive sequence: < 60 ms Time-dependent undervoltage, U t < < 50 ms Undervoltage and re-active power low, U Q < <250 ms UL markings: Wiring: Use 60/75 o C copper conductors only Wire size: AW Terminal tightening torque: 5-7 lb-in Mounting: For use on a flat surface of a type 1 enclosure Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) DEIF A/S Page 30 of 32

31 200 data sheet UK Unit dimensions 6. Unit dimensions 6.1 Unit dimensions in mm (inches) 312 (12.28) 87 (3.43) 8 (0.31) 219 (8.62) 204 (8.03) 297 (11.69) DEIF A/S Page 31 of 32

32 200 data sheet UK Ordering information 7. Ordering information 7.1 Order specifications and disclaimer Variants Mandatory information Additional options to the standard variant Item no. Type Variant no. Option Option Option Option Option Option Example Mandatory information Additional options to the standard variant Item no. Type Variant no. Option Option Option Option Option Option C2 H2 L Accessories Mandatory information Item no. Type Accessory Example: Mandatory information Item no. Type Accessory Accessory for 200 Ethernet cable - 3 m crossed (J4) Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. DEIF A/S Page 32 of 32

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications DATA SHEET Advanced enset Controller, 200 Operation modes Display and unit front eneral Engine control M-Logic Optional applications DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45

More information

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET 200 Automatic DATA SHEET Operation modes Automatic mains failure/ats Island operation Fixed power/base load Peak shaving Load takeover Mains power export Multiple gen-set load sharing (128) Display and

More information

AGC 200 Advanced Gen-set Controller DATA SHEET

AGC 200 Advanced Gen-set Controller DATA SHEET AGC 200 Advanced Gen-set Controller DATA SHEET Operation modes Automatic mains failure Island operation Fixed power/base load Peak shaving Load take over Mains power export Protection (ANSI) 5 x Overload

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DATA SHEET Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DATA SHEET Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management DATA SHEET AGC PM Automatic Genset Controller, Plant Management Management of up to 992 gensets Island and parallel operation Plant black start capabilities Fuel-optimised control Integrated genset protection

More information

Automatic Gen-set Controller Multi-line D

Automatic Gen-set Controller Multi-line D Multi-line 2 4921240295D SW version.20.0 or later Standard functions Operation modes Automatic mains failure Island operation Fixed power/base load Peak shaving Load take over Mains power export Push-buttons

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AGC 200 Advanced Gen-set Controller Mounting Terminal strip overview I/O lists Wiring Document no.: 4189340610C SW version 3.5X.X or later Table of contents 1. ABOUT THIS DOCUMENT...

More information

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General DATA SHEET Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:

More information

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions Multi-line 2 492124027H SW version 2.1.X or later DEIF A/S Applications AMF (no synchronising) Island mode (stand alone) Generator controls Engine start/stop Configurable start sequence Protection and

More information

Basic Gen-set Controller multi-line F SW version 2.31.X or later

Basic Gen-set Controller multi-line F SW version 2.31.X or later multi-line 2 492124027F SW version 2.1.X or later Standard functions DEIF A/S Applications AMF (no synchronising) Island mode (stand alone) Generator controls Engine start/stop Configurable start sequence

More information

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X Multi-line 2 4921240335A SW version 2.4X.X Standard functions Applications Measuring system DEIF A/S Generator protection for hydro turbine driven generators Functions 2 sets of alarm set points Alarm

More information

DATA SHEET Genset Controller, GC-1F

DATA SHEET Genset Controller, GC-1F DATA SHEET Genset Controller, Engine control Generator monitoring Generator protection (ANSI) Mains monitoring Mains protection (ANSI) Engine monitoring Display panel DEIF A/S Frisenborgvej 33 DK-7800

More information

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET DATA SHEET Generator Protection (ANSI) 2 x reverse power (32) 5 x overload (32) 6 x overcurrent (50/51) 2 x overvoltage (59) 3 x undervoltage (27) 3 x over-/underfrequency (81) Voltage dependent overcurrent

More information

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General DATA SHEET Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45

More information

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General DATA SHEET Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

DATA SHEET Automatic Genset Controller, AGC-3

DATA SHEET Automatic Genset Controller, AGC-3 DATA SHEET Automatic enset, AC-3 Operation modes Engine control enerator protection (ANSI) Display /busbar protection (ANSI) M-Logic (Micro PLC) eneral DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45

More information

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET DATA SHEET Generator protection (ANSI) 2 x reverse power (32) 5 x overload (32) 6 x overcurrent (50/51) Inverse time overcurrent (51) 2 x overvoltage (59) 3 x undervoltage (27) 3 x over-/underfrequency

More information

DATA SHEET IOM 200 analogue interface for AGC 200

DATA SHEET IOM 200 analogue interface for AGC 200 DATA SHEET IOM 200 analogue interface for AGC 200 CAN interface to AGC 200 series TTL interface to PC LED indicators for unit and CANbus status GOV/AVR outputs selectable for DC current or DC voltage DEIF

More information

Generator Controller GC-1

Generator Controller GC-1 4921240293F Standard functions DEIF A/S Engine control Start preparation (preheater or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel solenoid selection (coil type) Idle

More information

Generator Controller GC-1F

Generator Controller GC-1F Controller 4921240310D Standard functions DEIF A/S Engine control Start preparation (preheating or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel solenoid selection (coil

More information

No longer for sale. Generator Controller GC-1. Data sheet. Standard functions

No longer for sale. Generator Controller GC-1. Data sheet. Standard functions 4921240293F DEIF A/S Engine control Start preparation (preheater or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel solenoid selection (coil type) Idle speed control Local

More information

Generator Paralleling Controller, GPC-3 DATA SHEET

Generator Paralleling Controller, GPC-3 DATA SHEET DATA SHEET Regulation modes Load sharing Fixed frequency Fixed power Frequency droop Generator protection (ANSI) 2 x reverse power (32) 5 x overload (32) 6 x overcurrent (50/51) 2 x overvoltage (59) 3

More information

DATA SHEET Automatic Genset Controller, AGC-4

DATA SHEET Automatic Genset Controller, AGC-4 DATA SHEET Automatic enset, AC-4 Single or synchronising gensets Power plant control Fast synchronising Control and protection Customised logic and control SW emulation of application DEIF A/S Frisenborgvej

More information

DATA SHEET Paralleling and Protection Unit, PPU-3

DATA SHEET Paralleling and Protection Unit, PPU-3 DATA SHEET Paralleling and Protection Unit, PPU-3 Regulation modes Generator protection M-Logic (Micro PLC) Busbar protection Free PC utility software Approved by all major classification societies DEIF

More information

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General DATA SHEET Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

PPM Protection and Power Management DATA SHEET

PPM Protection and Power Management DATA SHEET PPM DATA SHEET Power Management Multiple master system Redundant internal communication Load-dependent start/stop Fuel optimisation logic Programmable start priority Heavy consumer control Blackout start

More information

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Compact Genset Controller, CGC 200 DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free

More information

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit Compact system in one unit Generator Paralleling Controller multi-line 2 4921240189L Generator synchronisation, protection and control True 3-phase RMS measurements, voltages and currents galvanically

More information

Engine Controller EC-1

Engine Controller EC-1 Engine Controller 4921240292E Standard functions Engine control Engine monitoring DEIF A/S Start preparation (preheater or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel

More information

PPU Power Management (PPM)

PPU Power Management (PPM) PPU anagement (PP) 4921240291H Standard functions DEIF A/S management Load dependent start/stop Programmable start priority Heavy consumer control Blackout start sequence Supervision/control of a shore

More information

Delomatic 4, DM-4 Land DATA SHEET

Delomatic 4, DM-4 Land DATA SHEET Delomatic 4, DATA SHEET Application Features Power Management control and protection of complex power systems including diesel, gas and turbine generators, as well as mains and tie breakers Highly flexible

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

Delomatic 4, DM-4 Marine & Offshore DATA SHEET Delomatic 4, DATA SHEET Application Power management control and protection of complex marine and offshore applications including diesel, gas and turbine generators, as well as tie breakers and shore connections

More information

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring INSTALLATION INSTRUCTIONS Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Option H3 Serial communication Profibus DP

Option H3 Serial communication Profibus DP MULTI-LINE 2 DESCRIPTION OF OPTIONS Option H3 Serial communication Profibus DP Description of option Functional description Parameters Data tables Document no.: 4189340443H Multi-line 2 Option H3, Serial

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

MULTI-LINE 2 APPLICATION NOTES

MULTI-LINE 2 APPLICATION NOTES MULTI-LINE 2 APPLICATION NOTES Converting PPM-2 to PPM 300 Parameter conversion Wiring Options I/O list Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

DATA SHEET Selectable AC transducer, TAS-321 DG

DATA SHEET Selectable AC transducer, TAS-321 DG DATA SHEET Selectable AC transducer, TAS-321 DG Bi-directional current measurement on AC networks Power measurement using 2 phases on 3-phase networks Class 0.5 (IEC688) measurement Easy configuration

More information

Installation Manual. Multi Power Controller MPC-1 multi-line D

Installation Manual. Multi Power Controller MPC-1 multi-line D Installation Manual Multi Power Controller MPC-1 multi-line Complete control system in one package: - island operation - parallel with mains operation - emergency generator control 3-phase AC measurements

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview Basic Gen-set Controller 4189340302G (UK) SW version 2.1X.X Mounting Board slot positions Terminal strip overview DEIF A/S I/O lists Wiring DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614

More information

Engine & Genset Controls Z, page 1 of 12

Engine & Genset Controls Z, page 1 of 12 Multi Differential Relay, MDR-2 Generator Protection Unit, GPU-2 Paralleling and Protection Unit, PPU-2 Multi Differential Relay for protection against short circuits and currents Engine and generator

More information

DATA SHEET Selectable AC transducer, TAS-331DG

DATA SHEET Selectable AC transducer, TAS-331DG DATA SHEET Selectable AC transducer, TAS-331DG Measures power or reactive power on 3-phase AC networks Class 0.5 (IEC-688) measurement Supply and measuring voltage up to 690 V Easy configuration via PC

More information

Engines & Gen-sets N, page 1 of 6

Engines & Gen-sets N, page 1 of 6 Uni-line ANSI code 27, 59 ANSI code 59 ANSI code 27 RMV-112D RMV-122D RMV-12D Under- /overvoltage protection: Overvoltage protection (2 levels Undervoltage protection (2 levels 1 minimum and 1 maximum

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Generator Paralleling Controller, GPC-3, and variants Generator Protection Unit, GPU-3, and variants Paralleling and Protection Unit, PPU-3 Mounting Board slot positions I/O lists

More information

Multiple Generator Automatic Synchronising System

Multiple Generator Automatic Synchronising System R Millennium Power Manufacturing Corp. R Multiple Generator Automatic Synchronising System Synchronising System Type Choice Independent Control Cabinet Type Feature: Independent Control Cabinet Type Functions:

More information

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version: MULTI-LINE 2 APPLICATION NOTES Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com

More information

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A DATA SHEET DEPRECATED - PCM DEIF A/S Frisenborgvej DK-800 Skive Tel.: +4 64 64 Fax: +4 64 6 info@deif.com www.deif.com Document no.: N/A AWC 00 PCM data sheet - DEPRECATED. AWC 00 system. System specifications...

More information

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options Description of options Option A and B, Loss of mains protection package Automatic Gen-set controller 4189340394B SW 2.3X.X Description of options Functional descriptions DEIF A/S Parameter list DEIF A/S,

More information

Genset control and protection with safety system

Genset control and protection with safety system APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts

More information

NOT RECOMMENDED FOR NEW DESIGNS

NOT RECOMMENDED FOR NEW DESIGNS DATA SHEET DELOMATIC 4, DM-4 Gas Gas engine control Integrated speed governor Integrated air/gas mix control Combined heat and power control Generator control and monitoring Mains failure protections integrated

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75 EMS-GC10 Genset Controller Modbus Communication Mapping Manual 1311311 2013-10-10 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Genset Controller Unit Model EMS - GC10. Installation Manual Section Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200 QUICK START GUIDE AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614

More information

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version: MULTI-LINE 2 APPLICATION NOTES Converting to Parameter conversion Wiring Options I/O list Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com

More information

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs QUICK START GUIDE Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3 QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3 What's in the delivery? Getting started The first steps PC

More information

InteliLite MRS17 Click Here to Learn More

InteliLite MRS17 Click Here to Learn More InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The

More information

Genset Controller, GC-1F

Genset Controller, GC-1F INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK Genset Controller, GC-1F Installation instructions Functional description Parameter list Document no.: 4189340472M This description includes the following

More information

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC QUICK START GUIDE Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300 QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107B 1. Introduction

More information

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description Description of options Option C1 Generator add-on protection package Multi-line 2 version 2 4189340267E SW version 2.42.X Description of options DEIF A/S Functional description Parameter list DEIF A/S,

More information

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X Description of options Option M2 Configurable engine control cards Multi-line 2 version 2 4189340482B SW version 2.4X.X Description of options Functional description DEIF A/S Display units Additional functions

More information

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC QUICK START GUIDE Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC QUICK START GUIDE Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer Installation and start up instructions TAS-331DG Selectable AC transducer 4189300008G (UK) Watt or var transducer Supply and measuring voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA00000KD Revision No: 1 This is to certify: That the Electrical Measuring and Protection Relay with type designation(s) PPU-3, GPU-3 - Generator Controllers

More information

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel INSTALLATION AND COMMISSIONING INSTRUCTIONS Compact Genset Controller, CGC 200 Mounting Terminals and wiring, using the Utility Software and/or the front panel DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.:

More information

DGC-2000 DIGITAL GENSET CONTROLLER

DGC-2000 DIGITAL GENSET CONTROLLER DGC-2000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-2000) offers an integrated alternative for genset control and monitoring. Control includes engine starting and shutdown

More information

DATA SHEET Advanced Graphical Interface, AGI 100 series

DATA SHEET Advanced Graphical Interface, AGI 100 series DATA SHEET Advanced Graphical Interface, AGI 100 series Graphic overview and touch screen control VNC server functionality* Compatible with DEIF controllers Easy programming Multi-language support IP65

More information

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300 QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107C 1. Introduction

More information

APPLICATION NOTES H-coupling

APPLICATION NOTES H-coupling APPLICATION NOTES H-coupling Application description Functional description Wiring Basic setup Flowcharts Document no.: 4189340548A SW version 3.3X.X or later Table of contents 1. WARNINGS AND LEGAL INFORMATION...

More information

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3 OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3 Display and push-button functions Alarm handling Log list

More information

POWER SYSTEM ACCESSORIES

POWER SYSTEM ACCESSORIES POWER SYSTEM ACCESSORIES Monitor III Software Applicable Controllers Software for Monitoring and Control of: Decision-Maker 550 generator set controller Decision-Maker 340 generator set controller Decision-Maker

More information

M-Logic Internal Logic Controller Description of M-Logic Functional description List of possible selections for logics

M-Logic Internal Logic Controller Description of M-Logic Functional description List of possible selections for logics MULTI-LINE 2 APPLICATION NOTES M-Logic Internal Logic Controller Description of M-Logic Functional description List of possible selections for logics DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614

More information

DATA SHEET Advanced Graphical Interface, AGI 300 series

DATA SHEET Advanced Graphical Interface, AGI 300 series DATA SHEET Advanced Graphical Interface, AGI 300 series For dedicated HMI solutions Advanced programming software For marine and harsh environments Available in 3 sizes: 4.3", 7" and 15" DEIF A/S Frisenborgvej

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

General introduction Part 2, chapter 11

General introduction Part 2, chapter 11 Delomatic 4 DM-4 Land/DM-4 Marine General introduction Part 2, chapter 11 DEIF A/S Page 1 of 8 Document no.: 4189232111C Table of contents 11. THE DELOMATIC SYSTEM IN GENERAL... 3 GENERAL INTRODUCTION...

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

AUTOMATIC TRANSFER SWITCH CC2 & AC5 CONTROL PANELS

AUTOMATIC TRANSFER SWITCH CC2 & AC5 CONTROL PANELS AUTOMATIC TRANSFER SWITCH CC & AC CONTROL PANELS HIMOINSA MANUFACTURES AUTOMATIC TRANSFER SWITCH PANELS (ATS) WHICH TRANSFER POWER BETWEEN THE MAINS AND THE GENERATOR SET. A PIECE DESIGNED WITH A COMPREHENSIVE

More information

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...

More information

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305 DATA SHEET Advanced Energy Meter, AEM 380 & AEM 305 Easy installation MID-approved 5 optional communication interfaces Phase error detection Low power consumption Two tariffs Two-pulse output DEIF A/S

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5520 AUTOMATIC MAINS FAILURE CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND

More information

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1 Engine Protection Controllers p18-1 18 Stand Alone en-set Controllers p18-2 Automatic Mains Failure en-set Controllers p18-3 Automatic Transfer Switch Controllers p18-6 Accessories p18-10 Software p18-11

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

InteliPro. Protection Relay for Parallel Applications. Technical Specification

InteliPro. Protection Relay for Parallel Applications. Technical Specification InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the

More information

GC2000 Generator Controller Power Management and Protection

GC2000 Generator Controller Power Management and Protection GC2000 Generator Controller Power Management and Protection Control. Monitor. Protect. A powerful generator controller and power management system for marine and offshore applications SELCO s GC2000 provides

More information

DATA SHEET Advanced Graphical Interface, AGI 100 series

DATA SHEET Advanced Graphical Interface, AGI 100 series DATA SHEET Advanced Graphical Interface, AGI 100 series Graphic overview and touch screen control Compatible with DEIF controllers Easy programming Create macro commands Multi-language support IP65 protected

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

DATA SHEET Applicable for offshore or nearshore

DATA SHEET Applicable for offshore or nearshore AWC 400 Advanced Wind Turbine Controller DATA SHEET Applicable for offshore or nearshore environments Unrivalled robustness 5-year warranty Open programming in ANSI C/C and IEC63-3 DEIF A/S Frisenborgvej

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

PGC 4000v2 POWER GENERATION CONTROLLER

PGC 4000v2 POWER GENERATION CONTROLLER PGC 4000v2 POWER GENERATION CONTROLLER THOMSON POWER SYSTEM PGC 4000v2 OFFERS THE FOLLOWING: Superior control & monitoring system for Thomson Power Systems advanced Series 2400 Switchgear (refer to separate

More information

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM MARINE & OFFSHORE DEIF HAS A LONG AND RICH HISTORY OF PROVIDING CLASS APPROVED, RELIABLE BRIDGE INSTRUMENTATION, SWITCHBOARD EQUIPMENT AND POWER CONTROL.

More information

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc.

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc. Digital control range for diesel/gas engine generators Si-TEC Xtend CGC/TGC DATA SHEET Models Si-TEC Xtend Recip Control is available in two variations: 4 CGC Co-Generation Control 4 TGC Total Generator

More information