1 Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) R1-LIT-VC3000-E01 Index Model Chart 2 Ordering Information 2 Ordering examples 2 Operation Overview 3 Typical one to one application set-up 4 Installation of VC A) Inside an electrical cabinet of a fan coil unit 5 B) Outside of a junction box or electrical cabinet 5 C) Enclosed low voltage junction box (if required by local codes) 5 Communication Wiring to VTR73xxA Terminal Equipment Controller 6 From the VTR73xxA to the first VC3xxxX 6 From VC3xxxX to the controller 7 Possible network wiring topology 7 Wiring of Remote Inputs to VC3504E & VC3404E 7 Terminals, Wire Identification & Ratings 8 Typical Wiring Example 9 Specifications 9 Dimensions 10 Important Notice 10 1
2 Model Chart Applications VC3500E5000 VC3504E5000 VC3400E5000 VC3404E pipes 2 pipes with reheat 4 pipes 2 pipes 2 pipes with reheat 4 pipes 2 pipes 2 pipes with modulating pulsed reheat 2 pipes 2 pipes with modulating pulsed reheat VC3300E5000 Slave Fan Unit Slave fan control only Fan control Up to 3 speed Up to 3 speed Up to 3 speed Up to 3 speed Up to 3 speed Monitoring inputs None 4 FCU remote inputs 4 FCU remote inputs 4 FCU remote inputs None Control types On-Off line switched valve output control On-Off line switched valve output control On-Off line switched valve output control On-Off line switched valve output control Slave fan control only - 1 heat / cool output -1 cool output -3 fan outputs - 1 heat / cool output -1 cool output -3 fan outputs -1 heat / cool output -1 Modulating pulsed Vdc output for SSR electric reheat control -3 fan outputs -1 heat / cool output -1 Modulating pulsed Vdc output for SSR electric reheat control -3 fan outputs 3 fan outputs Ordering Information Please refer to the Operation overview section for related information on VTR73xxA and VC3xxxX arrangements and possible combinations. More than one VC3xxxX relay pack can be used for a single VTR73xxA terminal equipment controller. Only one VC3x04E relay pack with monitoring inputs can be used for a single VTR73xxA terminal equipment controller. Ordering example: A VC3500E5000 is for a 90 to 277 Vac powered FCU mounted relay pack with the following outputs: Three 90 to 277 Vac switching fan relay outputs Two 90 to 277 Vac switching valve relay outputs A VC3504E5000 is for a 90 to 277 Vac powered FCU mounted relay pack with the following inputs and outputs: One configurable universal input One configurable binary input One dedicated discharge air temperature monitoring input One dedicated return air temperature control input Three 90 to 277 Vac switching fan relay outputs Two 90 to 277 Vac switching valve relay outputs 2
3 A VC3300E5000 is for a 90 to 277 Vac powered FCU mounted relay pack with the following outputs: Three 90 to 277 Vac switching fan relay outputs Operation overview The VC3xxxX series line voltage switching transformer relay pack functions as a slave unit under the control of a single master VTR73xxA terminal equipment controller. Fan operation can be configured and wired for the following: 3 Speed configuration using 3 fan relays ( Low Med - High ) 2 Speed configuration using 2 fan relays ( Low - High ) 3 Speed configuration with Auto fan speed mode using 3 fan relays ( Low Med - High ) 2 Speed configuration with Auto fan speed mode using 2 fan relays ( Low - High ) Single fan speed configuration. The VTR7300 controller can be configured for typical 2 or 4 pipe heating and cooling fan coil unit applications. 2 or 4 pipe only operation can be configured and wired for the following: Cooling only Heating only Cooling and heating with network or local auto changeover 2 or 4 pipe only with electric reheat can be configured and wired for the following: Cooling only Heating only Cooling and heating with network or local auto changeover On-Off electric reheat only Cooling with on-off or modulating Vdc pulsed electric reheat ( model dependent ) Heating with on-off or modulating Vdc pulsed electric reheat ( model dependent ) Cooling and heating with network or local changeover with on-off or modulating Vdc pulsed electric reheat ( model dependent ) The VC3xxxX relay pack supplies power to the wall VTR73xxA terminal equipment controller. The VTR73xxA controller operates the VC3xxxX relay pack via a simple communication bus. A maximum of 10 VC3xxxX relay pack can be used under a single VTR73xxA terminal equipment controller. 3
4 3 wires minimum are required between the VTR73xxA controller and the first VC3000 relay pack. The 3 wire functions are as follow: 1 Tx / Rx communication 2 power hot 7.0 Vdc 4 Watts maximum ( required for the VTR73xxA controller power ) 3 power common Commands for fan speed and valve operation are issued from the VTR73xxA terminal equipment controller to the VC3xxxX relay pack. Typical one to one application set-up Local Inputs at VTR7300 Controller Special optional local function(s): - Remote motion detector(s) - Window contacts - Occupancy card holder Existing or New Field VTR7300 Wires 3 minimum required Ga Solid or Stranded Existing or New Communication Field Wires - BACnet MS -TP - LON TP -FT 10 - Wireless ( No wires ) High Voltage in cabinet wiring - Line powered 90 to 277 Vac - Line switching of fan & valves 90 to 277 Vac - Isolated heating output for electric reheat Model Dependent Optional FCU Monitoring Inputs - Service or Filter alarms - Supply air sensor - Return air sensor - Changeover sensor or contact Line Voltage Power Line Voltage Valves - 2 pipes or 4 pipes applications - Isolated line switching for electric reheat H C Line Voltage Fan - Configurable - Up to 3 speed fan control - Auto fan speed Installation IMPORTANT: ALL WIRING MUST CONFORM TO LOCAL AND NATIONAL ELECTRICAL CODE REGULATIONS. Please read the following instructions carefully before proceeding with the installation. Failure to follow the instructions could damage the product or cause a hazardous condition. Installation must be performed by a qualified service technician or electrician. Disconnect power supply before installing in order to prevent electrical shock. 4
5 There are three basic methods for installing the VC3000 transformer relay pack controller. A) Inside an electrical cabinet of a fan coil unit Use the plastic mounting tabs to secure the unit to the inside of the electrical enclosure. Secure to the inside with screws. Cut one or both plastic mounting tabs if space is needed inside the enclosure. Install a low voltage or high voltage metal separator if required (fig. 1). Do not exceed the maximum rated temperature of the unit. (65 o C/149 o F) Fig. 1 TYPICAL COIL UNIT Electrical Cabinet H C C C Low Voltage Connections to VTR7300 Controller B) Outside of a junction box or electrical cabinet Use the supplied lock nut to secure the transformer relay pack to the electrical junction box or to the electrical cabinet of the fan coil unit. C) Enclosed low voltage junction box type installation (if required by local codes) Install the transformer relay pack inside a 4 x 4 junction box. Cut one or both plastic mounting tabs if space is needed inside the enclosure. Use the supplied lock nut to secure the transformer relay pack (inside its junction box) to the main electrical junction box or to the electrical cabinet of the fan coil unit. 5
6 If replacing an old line voltage fan coil thermostat, label the wires before removal of the old thermostat. Electronic controls are static sensitive devices. Discharge yourself of any electrostatic build-up before manipulating or installing the terminal equipment controller. A short circuit or wrong wiring may permanently damage the terminal equipment controller or the equipment. VC3000 series transformer relay packs are to be used only as operating controls. If installed incorrectly the intended application may fail or lead to personal injury or loss of property. It is the responsibility of the end user to ensure that the device has been properly installed by a certified professional and that proper safety precautions have been taken to protect against failures. Communication Wiring to VTR73xxA Terminal Equipment Controller VTR73xxA Terminal Controller 3 - Tx / Rx 4-7 Vdc Power Hot 5 - Power Common VC3504E Relay Pack 1 - Tx / Rx 2-7 Vdc Power Hot 3 - Power Common VC3300E Relay Pack 1 - Tx / Rx 2-7 Vdc Power Hot 3 - Power Common To other VC3xxxX Relay Pack Only one VC3xxxX relay pack with remote monitoring inputs can be used under a single VTR73xxA controller. All other slave units must be either VC3xxxX relay pack(s) WITHOUT remote inputs. A maximum of 10 VC3xxxX relay packs can be used for a single VTR73xxA terminal equipment controller. From the VTR73xxA to the first VC3xxxX o Existing or new field wires o 3 minimum required Ga solid or stranded. Shield not necessary. 6
7 From the first VC3xxxX to the controller to all other VC3xxxX Relay Pack(s) o Existing or new field wires o 2 minimum required Ga solid or stranded. Shield not necessary. o Connect only common and 2 Tx / Rx communication Possible network wiring topology The VTR7300 to VC3000 transformer relay pack can use any network wiring topology as required or based on topology of existing wires. Daisy Chained Topology Mixed Daisy Chained & Star Topology Star Topology Wiring of Remote Inputs to VC3504E and VC3404E VC30x04E Relay Pack 4 - RUI1 5 - Scom 6 - RBI2 7 - SS 8 - RS Remote RUI 1 Input by configuration: - None ( monitoring only ) - Local changeover sensor ( 10K type2 COS ) - Local changeover contact ( COC NO or COC NC ) - Service alarm ( Service ) - Filter Alarm ( Filter ) Remote RBI 2 Input by configuration: - None ( monitoring only ) - Service alarm ( Service ) - Filter Alarm ( Filter ) SS Supply sensor: - 10K type2 monitoring only - Auto dectected RS Return Air Sensor: - 10K type2 main temperature copntrol - Auto dectected ( by-passes VTR73xxA internal sensor ) OR 7
8 Terminals, Wire Identification & Ratings VC3500E5000 VC3504E5000 VC3400E5000 VC3404E5000 VC3300E5000 Slave Fan Unit Low Voltage Terminals No local inputs Low voltage inputs No local inputs Low voltage inputs No local inputs Power Supply Fan line voltage contact Wire connections 1/2 HP maximum Valve line voltage contact output Yellow Wire connection 5A maximum Line voltage contact Wire connections 10A Maximum 1 Tx / Rx Tx / Rx Tx / Rx Tx / Rx Tx / Rx 2 7 Vdc 7 Vdc 7 Vdc 7 Vdc 7 Vdc 3 Com Com Com Com Com 4 RUI 1 RUI 1 5 Scom Scom 6 RBI 2 RBI 2 7 SS SS 8 RS RS 9 Heat - Heat - 10 Heat + Heat + LINE VOLTAGE CONNECTIONS 3 Fan speed control Brown, Blue, Red 4 Pipe Cool output, or 2 Pipe Heat/ Cool output 4 Pipe Heat output, or 2 Pipe Reheat output - 90 to 277 Vac universal all models - Black Hot L1 Power Vac (Switches: Brown, Blue, Red and Yellow) - White neutral power Vac 3 Fan speed control Brown, Blue, Red 4 Pipe Cool output, or 2 Pipe Heat/ Cool output 4 Pipe Heat output, or 2 Pipe Reheat output 3 Fan speed control Brown, Blue, Red 3 Fan speed control Brown, Blue, Red 2 Pipe Heat/ Cool output 2 Pipe Heat/ Cool output N/A N/A N/A N/A 3 Fan speed control Brown, Blue, Red Tx / Rx 7 Vdc Com Power Supply Beyond Comfort VC3500E Vac - 50/60 Hz 10A 1/2HP Max WHITE BLACK Tx / Rx 7 Vdc Com RUI 1 SCom RBI 2 SS Power Supply Beyond Comfort VC3504E Vac - 50/60 Hz 10A 1/2HP Max WHITE BLACK Tx / Rx 7 Vdc Com Power Supply Beyond Comfort VC3400E Vac - 50/60 Hz 10A 1/2HP Max WHITE BLACK Tx / Rx 7 Vdc Com RUI 1 SCom RBI 2 SS Power Supply Beyond Comfort VC3404E Vac - 50/60 Hz 10A 1/2HP Max WHITE BLACK Tx / Rx 7 Vdc Com Power Supply Beyond Comfort VC3300E Vac - 50/60 Hz 10A 1/2HP Max WHITE BLACK RED 8 RS RED LOW LOW BLUE BLUE MED MED 9 BROWN BROWN HIGH HIGH RED LOW Heat- BLUE MED Heat+ BROWN HIGH RS RED LOW Heat- BLUE MED Heat+ BROWN HIGH RED LOW BLUE MED BROWN HIGH COOL YELLOW COOL YELLOW COOL YELLOW COOL YELLOW Use copper conductors only. ORANGE ORANGE Use copper conductors only. Use copper conductors only. HEAT HEAT ORANGE ORANGE Use copper conductors only. Use copper conductors only. 8
9 Typical Wiring Example Brown - High Speed Blue - Medium Speed Red - Low Speed M M M 3 Speed 2 Speed Single S peed Applications Applications Applications Black - Hot Power Orange - Connected to Black-Hot White - Neutral Fan Speed Arrangement By Configuration Orange - Heating Valve Yellow - Cooling Valve V V VC3504E Relay Pack For 2 pipe applications use cooling valve yellow wire connection Orange - Electric Reheat R For electric reheat applications where current draw is under above 10 A use a line powered coil pilot duty relay or contactor for the heating element in place of the heating valve. Specifications Power supply: 90 to 277 Vac universal, Hz Fan line voltage contact electrical ratings: Brown, Blue, Red wires ½ HP maximum Main heat and cool line voltage contact electrical ratings: Yellow wire 10A maximum Isolated heat line voltage contact electrical ratings: Orange wires 10A maximum VTR73xx terminal equipment controller power output: 7.0 Vdc +/ - 10 C% 2.4 watts minimum Output ratings: - Heat valve: Vac maximum (orange wire) - Cooling valve: Vac maximum (yellow wire) - Fan 1/2 277 Vac maximum (red, blue, brown wire(s)) Operating conditions: 0 0 C to 50 0 C (32 0 F to F) 0% to 95% R.H. non - condensing Storage conditions: C to 50 0 C (-22 0 F to F) 0% to 95% R.H. non - condensing Approximate shipping weight: Agency approvals all models: 0.75 lb (0.34 kg) ctuvus: UL 873 (US) and CSA C22.2 No. 24 (Canada) CE: LVD 2006/95/EC (Europe Union) CE: EMC 2004/108/EC (Europe Union) CE for RF: RTTE 1999/5/EC FCC: Compliant to: Part 15, Subpart B FCC for RF: Compliant to: Part 15, Subpart C 9
10 Dimensions 1.30" 3.15" 3.94" 4.80" 2.75" 3.15" Important Notice VC3000 series transformer relay packs are to be used only as operating controls. If installed incorrectly the intended application may fail or lead to personal injury or loss of property. It is the responsibility of the end user to ensure that the device has been properly installed and that proper safety precautions have been taken to protect against possible failures. Tampering with the devices or incorrect application of the device will void warranty. 10
11
12 Beyond Comfort Viconics Electronics Inc Langelier Blvd. I St-Leonard I Quebec I Canada I H1P 3K9 Tel.: (514) I Fax: (514) I Toll free: sales@viconics.com I E01
Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet
Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet Application specific room controller with customizable screen colors. The VTR8300 is a line-voltage
More informationRoom Controllers. SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers SC3000 Relay Pack The SC3000 is a relay pack for line-voltage fan coil units. The device is used with SER7300 and SER8300
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationApplication Guide. Fan Coil (FCU) Application Guide. VTR8000 Series Room Controllers. Control Performance Energy savings Better building management
Application Guide Fan Coil (FCU) Application Guide VTR8000 Series Room Controllers Control Performance Energy savings Better building management Application Guide VTR8000 Fan Coil Controller 2 TABLE OF
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationVZ7000 Series. BACnet Commercial Zoning System
VZ7000 Series BACnet Commercial Zoning System A cost-effective, scalable zoning system for the commercial market that delivers unparalleled flexibility via the open BACnet communication protocol. VZ7000
More informationModular Room Control (MRC) Series Expansion Board
Installation Instructions Issue Date December 13, 2002 Modular Room Control (MRC) Series Expansion Board Application The Modular Room Control (MRC) system has the ability to expand its input/output capabilities
More informationNT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation
More informationSE7600E Series Application Guide
Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available
More informationNT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation on RS485 communication failure Retention of temperature set-point
More informationP216 Series Condenser Fan Speed Controller
P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version
More informationP216. Condenser fan speed controller. Product bulletin. Features
P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure
More informationSER8300 Room Controller
SER8300 Room Controller Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colors. The SER8300 is a line-voltage fan coil room controller
More informationclarity 3 Programmable Controller
clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated
More informationFX Input/Output (I/O) Modules XM07 and XM14
Product Bulletin FX I/O Modules Issue Date July 6, 2009 FX Input/Output (I/O) Modules XM07 and XM14 The FX Input/Output (I/O) Modules provide additional physical input and output points for FX field controllers
More informationViconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification
Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated
More informationRoom Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack
Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colours. The SER8300 is a line-voltage fan coil terminal
More informationVT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications
Product overview VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications 1 The VT7200 PI thermostat family is specifically designed for zoning applications. Typical applications
More informationRS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units
NT10 Series Revision Date April 16, 2014 RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on RS
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationDigital Lighting Systems, Inc.
, Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual
More informationRoom Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers
More informationX47.CE Product Guide
X47.CE Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Features... Page 2 Technical Overview... Page 3 Installation... Page 5 Commissioning... Page 5
More informationMAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration
Data Sheet Lighting Relay Panel Overview Leverage the Power of BAS Integration Exterior with Surface Mount Trim The Series UL Listed, Lighting Control Panel provides the capability to control high voltage
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationDatasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview
Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationDTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A
DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current
More informationBACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview
Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling with
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationETM-2040 Service Manual
Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes
More informationWireless General Purpose Adapter (WGA100) Installation Instructions
(WGA100) Installation Instructions Daintree s WGA100 DT111 forms (Rev. part 12.8.17) of the Daintree ControlScope control solution for commercial and industrial buildings. It transmits and receives messages
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationETM-2050/ETM-2051 Service Manual
Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes
More informationVRP5045W1045W 24 VAC Powered ZigBee Repeater For Schneider-Electric Wireless Networks Applications
1 24 VAC Powered ZigBee For Wireless Networks Applications Product overview The wireless repeater has been specifically designed to be used within a wireless ZigBee network, for wireless controllers. The
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationSE8300 Room Controller
SE8300 Room Controller Low Voltage Fan Coil Controller and Zone Controller Application Specific low voltage Room Controller with customizable covers and screen colors. Suitable for commercial and high
More information8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A
8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.
More informationSTR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions
STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA
More informationTAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta
TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationViconics VT7682S Wireless Central Manager Application Guide
Viconics VT7682S Wireless Central Manager Application Guide VT7682S_Application_Guide-E00 (028-6041 R0 Issue Date: January 10 th, 2012) Table of Contents Product Overview... 1 1.1. Features & Benefits...
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationSEZ7000 Series. Wireless Commercial Zoning System
SEZ7000 Series Wireless Commercial Zoning System A cost-effective, scalabe zoning system for the commercial market that delivers unparalleled flexibility via the ZigBee communication protocol. SEZ7000
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationdiode led 12VDC CONSTANT VOLTAGE DRIVER SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.
diode led a division of elemental LED 12VDC CONSTANT VOLTAGE DRIVER 12VDC SPECIFICATION SHEET OVERVIEW 12VDC Constant Voltage LED Drivers are the driver of choice to pair with 1V switches, low voltage
More informationTF243 Series Digital Thermostat Fan Coil Unit Control
TF243 Series Digital Thermostat Fan Coil Unit Control Features SPECIFICATION DATA General The TF243 series digital thermostat is designed for 3-speed fan and modulating valve control in a fan coil system,
More informationTC-9102 Terminal Controller
Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1095 TC-9102 Terminal Controller The TC-9102 Terminal Controller, the latest addition to the
More informationHardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN
Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN November 2005 Tracer MP581 Programmable Controller Hardware
More informationSCD96 DMX Output Interface. Installation guide
SCD96 DMX Output Interface Installation guide Contents Introduction 2 Welcome 2 Dimensions 2 Specification 2 Safety 3 Please read this first 3 Mounting 4 Location and spacing 4 Ambient atmosphere requirements
More informationdiode led 24VDC CONSTANT VOLTAGE DRIVER SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.
diode led a division of elemental LED 24VDC CONSTANT VOLTAGE DRIVER 24VDC SPECIFICATION SHEET OVERVIEW 24VDC Constant Voltage LED Drivers are the driver of choice to pair with 120V switches, low voltage
More informationSatellite INSTALLATION GUIDE
N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationADC7520 SERIES. 1600W Battery Chargers and Power Supplies
ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave
More informationField selectable application type and room module series, via dip-switches on controller
TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSEZ7260X5x45B Installation Guide for BACnet MS/TP Zone Controller
SEZ7260X5x45B Installation Guide f BACnet MS/TP Zone Controller CONTENTS Installation 2 Location 2 Installation 2 Typical Applications 4 Main outputs wiring 5 Wiring examples 8 CO2 Sens wiring 8 Configuring
More informationSE7600E Series Application Guide
SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationSmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationBACnet Product Overview
BACnet Product Overview Comfort and energy-saving of a HVAC system are all about control. With networking devices, you can monitor and control your equipment via a communication system anywhere and anytime
More informationSEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS
SEZ7656E1045B Installation Guide f BACnet MS/TP RTU Terminal with IAQ Control CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal, Identification and Function 4 Wiring 4
More informationUser Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.
User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationRoom Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack
Compatible with SmartStruure solution SmartStruure Lite solution Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationRXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13
s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationCompactBlock Guard I/O EtherNet/IP Safety Modules
Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval
More informationENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS
POWER MONITORING ENERCEPT Networked Power Transducer (Modbus RTU) DANGER US Patent No. 6,373,238 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in
More information20AMP Plug Load Controller
Project name Prepared by Date INDOOR AIRLINK LUTRON Catalog#: ALPP 20A or ALPP 20ACC Part #: 624097 or 655228 The 20AMP plug load controller is a radiofrequency (RF), receptacle switching solution that
More informationAirflow Pressure Sensor
Desigo TRA Airflow Pressure Sensor DXA.S04P1... Airflow Pressure Sensor (APS) is used to measure airflow for room pressurization and fume hood control applications. Differential Pressure (velocity) is
More informationSEZ7656R1045B / SEZ7656H1045B
SEZ7656R1045B / SEZ7656H1045B Installation Guide f BACnet MS-TP RTU / HP Room Controllers F Commercial Zoning Systems CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal,
More informationComponent identification
IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that
More informationInstallation Instructions
Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for
More informationTHERMOSTATS & CONTROLLERS
DESCRIPTION The Belimo ZIP Economizer Series saves energy in buildings by using cool outside air as a means of cooling the indoor space. This application can drastically reduce HVAC energy costs while
More informationDOR6. Components All functions and indications are on the front of the module. Characteristics
Priva Blue ID C-Line Relay output module Easy installation You simply click the module onto the DIN rail. The wiring connects to the module via spring terminals or screw connectors (optional). The module
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationOutput Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W
Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted
More informationSuitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.
TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with
More informationSpecification Sheet For electronically commutated motors
SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes
More information