SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS

Size: px
Start display at page:

Download "SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS"

Transcription

1 SIZE, AND POLYAMIDE PRE-DRILLED CONTROL STATIONS Size, and pre-drilled control stations with component fixed on the base* Compact enclosure, polyamide body and cover x M0 clearance entries at the bottom Supplied with earth terminals ( x.5 mm²) White self-adhesive dilophane identification label 58 x 8 mm A stainless steel fast multi-threaded screw ( / turn) Contact components fixed to the base of the box on integrated vertical DIN rail Sizes Pre-drilled cover function functions function (for 4-pole switch 0988 to ) (takes only 4-pole switch 0988 to ) in bottom position inspection window for ammeter 48 x 48 (takes only 4-pole switch 0988 to ) + ammeter window Zone & - & T = 55 C IP66 IK09 Zones : and and - - Conforming to ATEX Directive - /9 EC - Standards EN EC 008 II G for gas - EC 008 II D - T = + 55 C for dust According to IEC - Conforming to standards IEC //7 Ex ed IIC DIPA TA = + 55 C Approved type PCe CENELEC LCIE 00 ATEX 6047 IEC LCIE Ex declaration of conformity No. 50 Conforming to standards EN and IEC 64-- ; Ik09 mechanical withstand according to EN C to + 55 C Dimensions (mm): Size enclousure Size enclousure Coupling everal enclosures: additional of joining kit to pre-drilled stations Pre-drilled with x M0 entries at the top and x M0 entries at the bottom Polyamide compact box and cover brass earth continuity plate White self-adhesive dilophane identification label 58 x 8 mm A stainless steel fast multi-threaded screw ( and a half turn) Contact components fixed at the bottom of the box on integrated vertical DIN rail Size enclousure 04 Fixing details Sizes Pre-drilled cover /9/6 Joining kit vertical control stations DIA

2 6 L STAINLESS STEEL COMPLETE AND PRE-DRILLED CONTROL STATIONS L stainless steel complete control stations clearance entries for M0 at bottom for sizes and clearance entries for M5 at bottom for size External earth White self-adhesive dilophane identification label 58 x 8 mm Boxes delivered with cable gland except ( cable Size box 0 x 0 mm NC + NO push-button with. NC + NO red EMERGENCY STOP. mushroom-head button, push-pull x 6 A double pole switch with positions. handle can be padlocked in position 0 NC + NO push-buttons with. 6 L stainless steel pre-drilled control stations Boxes delivered without cable glands Size (0 x 0 mm) Pre-drilled cover for function (takes x 4-pole switch 0988 to ) Pre-drilled cover for Size (80 x 0 mm) Pre-drilled cover for (takes x 4-pole switch 0988 to ) Pre-drilled cover for functions Zone & - & T = 55 C IP66 IK 0 Zones : and and - Classification: - Conforming to ATEX Directive - /9 EC - Standards EN EC 008 II G for gas - EC 008 II D - T = + 55 C for dust - Conforming to standards IEC //7 Ex ed IIC DIPA TA = + 55 C Approved type JBe CENELEC LCIE 0 ATEX 68X IEC LCIE Ex.0.00X declaration of conformity No. 50 Conforming to standards EN et IEC 64-- Ik0 mechanical resistance according to EN C to + 70 C Size box Size box fix.00 ø Size (80 x 80 mm) (takes x 4-pole switches 0988 to ) Size box fix.00 ø

3 0 70 AD ALUMINIUM COMPLETE AND PRE-DRILLED CONTROL STATIONS Aluminium complete control stations clearance entries for M0 at bottom for sizes and clearance entries for M5 at bottom for size External earth White self-adhesive dilophane identification label 58 x 8 mm Boxes delivered with cable gland except ( cable Size box 0 x 0 mm NC + NO push-button with NC + NO red EMERGENCY STOP mushroom-head button, push-pull x 6 A double pole switch with positions handle can be padlocked in position 0 NC + NO push-buttons with. Aluminium pre-drilled control stations Boxes delivered without cable glands Size (0 x 0 mm) Pre-drilled cover for function 0.9 (takes x 4-pole switch 0988 to ) Pre-drilled cover for 0.9 Size (70 x 0 mm) Pre-drilled cover for. (takes x 4-pole switch 0988 to ) Size (0 x 0 mm) Pre-drilled cover for.5 (takes x 4-pole switches 0988 to ) Pre-drilled cover for functions Zone & - & T = 55 C IP66 IK 0 Zones : and and - Classification: - Conforming to ATEX Directive - /9 EC - Standards EN EC 008 II G for gas - EC 008 II D - T = + 55 C for dust - Conforming to standards IEC //7 Ex ed IIC DIPA TA = + 55 C Approved type JBe CENELEC LCIE 0 ATEX 6047 IEC LCIE Ex declaration of conformity No. 50 Conforming to standards EN et IEC 64-- Ik0 mechanical resistance according to EN C to + 60 C Size box Size box Size box

4 0 70 AD POLYESTER COMPLETE AND PRE-DRILLED CONTROL STATIONS Polyester complete control stations clearance entries for M0 at bottom for sizes and clearance entries for M5 at bottom for size External earth. Supplied with earth continuity plate White self-adhesive dilophane identification label 58 x 8 mm Boxes delivered with cable gland except ( cable Size box 0 x 0 mm Push-button with 0.8 NO + NC contacts red EMERGENCY STOP mushroom-head 0.8 button, push-pull NO + NC contacts 6 A double pole switch padlockable 0.8 in position 0 ; NO + NC contacts Push-buttons with red (0),. green (I) inserts NO + NC contacts Size box 0 x 0 mm green indicator push-buttons with NO + NC red indicator push-buttons with NO + NC Size (0 x 0 mm) Pre-drilled cover for (takes x 4-pole switch 0988 to ) Pre-drilled cover for functions Polyester pre-drilled control stations Size (0 x 0 mm) Pre-drilled cover for function (takes x 4-pole switch 0988 to ) 0.7 Pre-drilled cover for Size (70 x 0 mm) 0.7 Pre-drilled cover for 0.9 (takes x 4-pole switch) Pre-drilled cover for functions Zone & - & T = 55 C IP66 IK 0 Zones : and and - According to CENELEC : - Conforming to ATEX Directive - /9 EC - Standards EN EC 008 II G for gas - EC 008 II D - T = + 55 C for dust - Conforming to standards IEC //7 Ex ed IIC DIPA TA = + 55 C According to UL : - AEx ed IIC - - UL: E 4068 Approved type PCe CENELEC LCIE 00 ATEX 6047 IEC LCIE Ex declaration of conformity No. 50 Conforming to standards EN and IEC 64-- Ik0 mechanical withstand according to EN C to + 60 C Size box 0 Size box 0 Size box Pre-drilled cover for functions + mounted ammeter inspection window. Horizontal DIN rail 0987

5 POLYESTER COMPLETE AND PRE-DRILLED CONTROL STATIONS Zone & - & T = 55 C IP66 IK 0 Polyester boxes Black box, for push-buttons, indicators, switches Complete functions to be fixed components Supplied with Gravoply 6 x 8 mm identification label (yellow with black engraving) Internal earth : x 4 mm² terminals -function box threaded entries for M5 cable gland at bottom Max. 6 double pole switches Horizontal side by side switch mounting only possible for single pole switches Cat. No / Ø 0 Cat. No x Ø 5, 90 Pack. Zones : and and - According to CENELEC : - Conforming to ATEX Directive - /9 EC - and to standards EN II G for gas T (*) II D T = (*) for dust - Conforming to standards IEC //7 - Ex ed IIC t (*) - DIPA TA = (*) for dust T(*) Class acc. to combinations T5 T4 T Surface temp for Ta = + 40 C 85 C 00 C 5 C 00 C Approved type CAe CENELEC LCIE 0 ATEX 648X IEC LCIE Ex 0.0X Declaration of conformity No. 505 Conforming to standards EN and IEC 64-- combustible dust Ik0 mechanical withstand according to EN to + 55 C 89

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Control Stations & Switches: Switches, Circuit Breakers and Break Glass Call Points SWE Series: 16 and 20 A Switches Increased Safety SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product

More information

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use

More information

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,

More information

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety MRE Series 16 and 32 Amp Multiple Socket Outlets Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air

More information

M C. Ex d M-0... control, monitoring and signalling devices

M C. Ex d M-0... control, monitoring and signalling devices Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial

More information

Control Units Ex e in Stainless Steel LCS*.*

Control Units Ex e in Stainless Steel LCS*.* Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,

More information

Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612

Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612 TECHNICAL DATA SHEET NEW PRODUCT Rev. 6-03/2013 Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612 Ex de Contact blocks SERIES M-0530, M-0531 1 - New Product Technical

More information

74 PS range Push-buttons, selectors and indicators Ø 22mm

74 PS range Push-buttons, selectors and indicators Ø 22mm 74 PS range Push-buttons, selectors and indicators Ø 22mm Push-buttons, selectors, indicators and 22mm diameter pre-drilled technopolymer enclosures. Ideal for the creation of signalling and control units

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

Actuators. Stackable Contact Blocks (1, 2, or 3) with Contact Blocks

Actuators. Stackable Contact Blocks (1, 2, or 3) with Contact Blocks Unicode 2 Series: Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Actuators Stackable Contact Blocks (, 2, or 3) Pilot Light Stackable Pilot Light with Contact Blocks Panel Mounting Adaptor

More information

SPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.

SPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision. SPECIALTY PRODUCTS Flameproof housing Zones 1-2 and 21-22 to encase video cameras. Used for onshore and offshore sites and process supervision. Description Page Camera Housing eries Video Camera Housings

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30 - Ex zone 1 and 2, as well as 21 and 22 - Metal enclosure - Available in stainless steel enclosure - Reed contacts, coded - Actuation

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements

More information

Cable entry systems for potentially explosive atmospheres

Cable entry systems for potentially explosive atmospheres Cable entry systems for potentially explosive atmospheres Directive 94/9/EC (ATEX) ATEX stands for ATmosphère Explosible and is the short name for the European Directive 94/9/EC, regulating the market

More information

Cable Entry Systems for Potentially Explosive Atmospheres

Cable Entry Systems for Potentially Explosive Atmospheres Cable Entry Systems for Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) KEL-ER KVT 80 ATEX stands for ATmosphères EXplosives and is the short name for the European Directive 94/9/EC, regulating

More information

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof 757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Push Buttons and Operator Interface New Product Catalog XAL Control Stations Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

Load Disconnect Switches and Motor Switches

Load Disconnect Switches and Motor Switches Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus

More information

Installation Equipments

Installation Equipments Installation Equipments BCZ8 Series Explosion-proof and Socke ts to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Four enclosure types; Four current ratings (1A, 32A, 3A, 12A);

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

BA414DF Fieldbus indicator Single variable

BA414DF Fieldbus indicator Single variable FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe

More information

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner SideControl Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Throughwiring. single-ended. twin-ended

Throughwiring. single-ended. twin-ended Ordering details ellk 9... 18 W - 58 W Ordering details Type Version Terminals Throughwiring single-ended Throughwiring twin-ended Cable gland/ thread Threaded plug Blanking plug Order No. ellk 18/18 ellk

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green 22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Position Switches Series 8070

Position Switches Series 8070 www.stahl.de > Enclosures of type of protection "Increased safety > Dimensions and characteristic values according to EN 50041 > Replaceable contact in flameproof enclosure > Positive opening contacts

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Ex emergency pull-wire switches Ex ZS 71

Ex emergency pull-wire switches Ex ZS 71 Features/Options: Ex zone 1 and 21 Metal enclosure 2 contacts Wire length up to 35 m Small design Release by push-button (VD) Available without unlocking mechanism (per EN 60947-5-1) Wire pull and breakage

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Control Switches for Panel Mounting Series 8003

Control Switches for Panel Mounting Series 8003 > Switch function many switching arrangements ( or spring-return) possible via coding easy change of the coding possible on site max. 2 pole > For > With flexible lead or spring cage terminal www.stahl.de

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Page 1 of 5. Increased Safety, Encapsulation and Dust

Page 1 of 5. Increased Safety, Encapsulation and Dust IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx

More information

P Series PlexPower Distribution Panelboards Increased Safety

P Series PlexPower Distribution Panelboards Increased Safety Applications The P Series PowerPlex panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Other

More information

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A X ECONTACTOR 20 A/32 A/63 A/125 A/200 A II2 G Ex de IIC, t 1 IP65 water-and dust-tight Integrated load-break switch Locking in connected or disconnected position by keying axis 178 X TECHNIL FEATURES X1

More information

PlexPower Factory Sealed Panelboard Increased Safety

PlexPower Factory Sealed Panelboard Increased Safety Applications The IEC PlexPower factory sealed panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66 Zone 1 21 2 22 SKX 12 SKX 15 IP 66 C 20 +55 IM2 Enclosures made of glassfibre reinforced polyester resin 4 basic enclosure sizes Alone or in various combinations of merged set Equipped with built in devices

More information

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary

More information

Connect. Cable glands, locknuts and accessories

Connect. Cable glands, locknuts and accessories Connect Cable glands, locknuts and accessories 234 Our range of xxxxxxxxxx cable glands has been expanded to offer the most high quality glands available. Our wide range includes BW, CW, and A1/A2 gland

More information

Ex Junction Boxes & Control Stations

Ex Junction Boxes & Control Stations www.fibox.com Ex Junction Boxes & Control Stations Fibox Oy Ab Keilaranta D Espoo, Finland Tel. + () Fax. + () E-mail: info@fibox.fi Homepage: www.fibox.com Fibox Ltd. -, Songdo-Dong, Yeonsu-Gu, Incheon,

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Product Overview Automation

Product Overview Automation EN DE Product Overview Automation Automation at a glance Ident Systems CIS3 CIS3A CIS3A - Mini Read system Read/write system Read system Read/write system Read system Read/write system Head Evaluation

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without

More information

SA-P. Ex e. Stainless steel captive screws. Metal plates riveted onto lid

SA-P. Ex e. Stainless steel captive screws. Metal plates riveted onto lid SA-P - Zone 1, 2, 21, 22 - Polyester junction boxes - Choice of 9 sizes - With antistatic property - IK10 mechanical strength - IP66 Metal plates riveted onto lid Stainless steel captive screws ORIGINAL

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTR 55 Ex Diffuse reflection light scanner with background suppression Dimensioned drawing en 01-2011/05 50113748 1 khz 5 400mm 200mm with black-white error < 10% 10-30

More information

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

Ex-control switch Typ 292 without and Typ 293 with measuring instrument Ex-control switch GHG 9 and GHG 9 GHG 9 GHG 9 Technical data Ex-control switch Typ 9 without and Typ 9 with measuring instrument with GHG 9 Switch with GHG Switch Marking accd. to 0//EU D II G Ex ed ia

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Technical Data. General specifications. Output type Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 1, 2, 21, 22 und Division 2, can be installed in hazardous areas

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface

More information

ExCos-P Pressure sensor 20 Pa Pa

ExCos-P Pressure sensor 20 Pa Pa ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX

More information

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Main Range of product Series name Product or component type Device short name Sensor design Body type Head type Material Fixing

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary

More information