Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety
|
|
- Camron Solomon Henry
- 5 years ago
- Views:
Transcription
1 SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 - IK9 or IK1 Electrical Data: Voltage Up to 69 V Amperage Up to 2 A Operating Temperature: 16 A 2 A -2 C to +4 C -2 C to +4 C 35
2 SWE Series: 16 and 2 A Switches Increased Safety ATEX / IEC IP66 - IK9 or IK1 Applications: Designed to prevent operation in explosive atmospheres during connect and disconnect operation of lighting and light power loads. For use in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries and other process industries. Features: 16 Amp version: Two bottom M2 clearance holes. Switch mechanism fixed at the bottom of the box. Termination: Type 1: 2.5 mm 2 Type 2: 2.5 mm 2 flexible/4 mm 2 solid Internal earth: 2 x 2.5 mm 2 terminals 1 x white self-adhesive laminated plastic label with black lettering (58 x 18 mm) 2 Amp version: Two M2 threaded entries on the bottom of the box. Switch mechanism fixed on the bottom of the box. Padlockable handle in position using maximum 4 padlocks (maximum handle dia. 8 mm and minimum 15 mm length). Termination: 2.5 mm 2 flexible / 4 mm 2 solid Internal earth: 2 x 4 mm 2 terminals 1 x yellow self-adhesive laminated plastic label with black lettering (65 x 18 mm) Standard Material of Fixtures: 16 Amp version: Polyamide box. A2 stainless steel coarse pitch screws (1 and a half turn). Polyamide cable glands. Nickel plated brass locknuts. 2 Amp version: Polyester box A2 stainless steel captive screws. Polyamide cable glands. Catalog Number Logic: SWE XX XXXX X X Series: SWE = SWE Series Zone 1, 2 21, 22 ATEX / IEC Certified Amperage: 16 = 16 A 2 = 2 A Switch Type: S = Switch C = Changeover- Switch Wiring Diagram No. X X XX Number of Poles: 1 = 1-Pole 2 = 2-Pole 3 = 3-Pole 4 = 4-Pole Ordering Information: 16 A Switch - Type 1 Padlockable handle. Two M2 polyamide cable glands (cable dia. 6.5 to 14.5 mm) on the bottom. Contact Configuration: 1 2 Type Diagram No. Type (kg) (dm 3 ) Number Number Changeover switch C SWE16C11AG pole S SWE16S21AG A Twist Button - Type 2 Non-padlockable handle. Two M2 clearance holes on the bottom. Type Diagram No. Type (kg) (dm 3 ) Number Number Changeover switch C SWE16C1A pole S SWE16S2A A Switch Padlockable handle. Two M2 polyamide cable glands (cable dia. 6.5 to 14.5 mm) on the bottom. Changeover switch C SWE2C1AG pole S SWE2S22AG pole S SWE2S31AG pole S SWE2S41AG Cable Entry: A = 2 x M2 Options: G = With Polyamide Cable Gland P = With Brass Earth Continuity Plate Switching Arrangement: 16 A Switch C11 Positions X 1 X 16 A Twist Button C1 Positions X 1 X 2 A Switch C1 Positions X 1 X S31 Positions X X X S41 Positions X X X X S21 Positions X X S2 Positions X X S22 Positions X X X Closed contact 351
3 SWE Series: 16 and 2 A Switches Increased Safety ATEX / IEC IP66 - IK9 or IK1 Technical Data: Main 16 Amps Type 1 16 Amps Type 2 2 Amps Rated Insulation Voltage 75 V 5 V 5 V Rated Operating Voltage 69 Vac 1 / 11 V DC 1 5 V 5 V Rated Operating Current 16 A 16 A 2 A Switching capacity: AC 1 16 A 69 V 16 A 5 V AC A 4 V AC 14 1 A 4 V AC A 415 V 6 A 5 V AC 21 16A 5V AC 23 16A 4V AC 3 8 A 5 V AC 3 4 A 69 V DC 1 1 A 24 V DC 1 6 A 6 V DC 1 6 A 11 V (*) DC 13 1 A 11 V DC 13 2 A 24 V Termination (flexible/solid) 2.5 mm 2 / 4 mm mm mm 2 / 4 mm 2 (*) 2 contacts connected in series Compliances: Hazardous Area Gas Dust Certified Type PCe Zones Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T6 Surface Temperature T8 C Ambient Temperature -2 C to +4 C CE Declaration of Conformity 5221 ATEX Certificate LCIE ATEX 6472 IEC Certificate LCIE Ex.17 Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 (Polyester) / IK9 (Polyamide) Dimensions (mm): 16 A Version A Version Standards: Ex standards EN / IEC 679-; 679-1; 679-7; ; Product standards EN / IEC ; ; EMC standards EN / IEC 5515; Other standards EN / IEC 6529 (IP); (IK) 352
4 SWE Series: 4, 63 and 16 A Switches Increased Safety 4 A / 63 A Version Compliance Data: ATEX - IEC: 16 A Version Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T5 or T4 Ex td A21 T95 C or T13 C IP66 - IK1 Electrical Data: Voltage Up to 69 V Amperage Up to 16 A Operating Temperature: 4 A and 63 A 16 A -2 C to +55 C -3 C to +55 C 353
5 SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Applications: Designed to prevent operation in explosive atmospheres during connect and disconnect operation of power loads. For use in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries and other process industries. Features: 63 Amp version: Padlockable handle in position O using max. 4 padlocks (max. handle dia. 8 mm and min. 15 mm length). 3 or 4-pole switch mechanism with one NO early break auxiliary contact. Main contact termination: 35 mm 2 Auxiliary contact termination: 2.5 mm 2 Cable entries: 1 x M32 clearance on top 1 x M32 and 1 x M2 clearance on bottom 2 x M32 polyamide cable glands (cable 1 to 25 mm) 1 x M2 blanking plug Yellow laminated plastic label with black lettering (65 x 18 mm) 16 Amp version: Hinged door. Closed with plastic double bar locks (key supplied). Supplied with 4 fixing lugs. Padlockable handle in position O. 3 or 4-pole switch mechanism with one NO early break auxiliary contact. Main contact termination: 12 mm 2 Auxiliary contact termination: 2.5 mm 2 Cable entries: 1 x M63 clearance on top 1 x M63 and 1 x M25 clearance on bottom 2 x M63 polyamide cable glands (cable 36 to 44 mm) 1 x M25 blanking plug Standard Materials: Polyester (GRP) box. 316L stainless steel box. A2 stainless steel captive screws. Polyamide cable glands and blanking plugs. Nickel plated brass locknut. Catalog Number Logic: SWE XX XXXX X X Series: SWE = SWE Series Zone 1, 2 21, 22 ATEX / IEC Certified Amperage: 4 = 4A 63 = 63 A 16 = 16 A Ordering Information: Switch Type: S = Switch C = Changer or Selector Switch Wiring Diagram No. X X XX Number of Poles: 3 = 3-pole 4 = 4-pole Contact Configuration: 1 2 Polyester Box: 63 A Switch 2 x M x M2 3-pole switch S SWE63S32EG Pole Switch S SWE63S42EG A Switch 2 x M x M25 3-pole switch S SWE16S32JG Pole Switch S SWE16S42JG Stainless Steel Box: 16 A Switch 2 x M x M25 4-pole switch S SWE16S42JS Options: G = With Cable Gland and Blanking Plug P = With Brass Earth Continuity Plate S = Stainless Steel Box Cable Entry: A = 2 x M2 B = 3 x M2 C = 2 x M25 D = 2 x M x M2 E = 2 x M x M2 Switching Arrangements: F = 2 x M4 + 1 x M2 G = 2 x M5 + 1 x M2 H = 2 x M x M2 J = 2 x M x M25 S32 Positions Aux X X X X S42 Positions Aux X X X X X 354
6 SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Technical Data: Main 63 Amps 16 Amps Rated Insulation Voltage 69 Vac 69 Vac Rated Operating Voltage 69 Vac 69 Vac Rated Operating Current 63 A 16 A Rated Surge Voltage 6 KV 8 KV Switching Capacity AC 21 A / AC 22 A 63 A 23 V to 69 V 16 A 4 V to 69 V AC 23 A 15 kw 23 V 22 kw 4 V 8 kw 4 V 3 kw 5 V 11 kw 5 V 55 kw 69 V 18.5 kw 69 V 11 kw 23 V AC kw 4 V 9 kw 4 V 22 kw 5 V 7 kw 5 V 15 KW 69 V DC A 22 V (*) 16 A 44 V (*) DC A 22 V (*) DC 23 Auxiliary Rated Insulation Voltage 4 V 23 V Rated Operating Voltage 4 V 23 V Rated Operating Current 1 A 1 A Switching Capacity: (*) 2 contacts connected in series per pole 1 A 44 V (*) 16 A 22 V (*) 63 A 44 V (*) AC 15 6 A 23 V 4 A 4 V 6 A 23 V Others Termination (flexible/solid) 35 mm 2 12 mm 2 Compliances: Hazardous Area Gas Dust Certified Type CAe (Polyester box) Zones Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T5 at +4 C T4 at +55 C Surface Temperature T95 C at +4 C T13 C at +55 C Ambient Temperature -3 C to +55 C, -2ºC to +55ºC (4 A & 63 A) CE Declaration of Conformity 5235 ATEX Certificate LCIE 2 ATEX 6248X IECEx Certificate LCI 4.16X Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 Hazardous Area Gas Dust Certified Type JBe (Stainless steel box) Zones Conforming to ATEX 94/9/CE CE 81 II 2 G CE 81 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T5 at +4 C T4 at +55 C Surface Temperature T95 C at +4 C T13 C at +55 C Ambient Temperature -3 C to +55 C CE Declaration of Conformity 5232 ATEX Certificate LCIE 2 ATEX 6118X IECEx Certificate LCIE Ex 2.1X Other Certifications GOST Index of Protection (solid and liquid) IP66 Impact Resistance (shock) IK1 Standards: Ex standards EN / IEC 679-; 679-1; 679-7; ; Product standards EN / IEC ; EMC standards EN / IEC 5515; Other standards EN / IEC 6529 (IP); (IK) 355
7 SWE Series: 4, 63 and 16 A Switches Increased Safety ATEX / IECEx IP66 - IK1 Dimensions (mm): 4 A / 63 A Polyester Version 16 A Polyester Version 16 A Stainless Steel Version.. 356
Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety
CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC
More informationJunction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety
PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product
More informationSIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS
SIZE, AND POLYAMIDE PRE-DRILLED CONTROL STATIONS 0986 00 0986 0 0986 0 0986 8 Size, and pre-drilled control stations with component fixed on the base* Compact enclosure, polyamide body and cover x M0 clearance
More informationMRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
MRE Series 16 and 32 Amp Multiple Socket Outlets Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air
More informationATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety
Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air conditioning equipment Compressors Pumps For use
More informationCable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof
757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP
More informationATX JBEA and ECEA Series Aluminum Enclosures Increased Safety
Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,
More informationCable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationViamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations
Applications For use in locations where: Flammable gases, vapors and dusts are present A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary Typical
More informationActuators. Stackable Contact Blocks (1, 2, or 3) with Contact Blocks
Unicode 2 Series: Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Actuators Stackable Contact Blocks (, 2, or 3) Pilot Light Stackable Pilot Light with Contact Blocks Panel Mounting Adaptor
More informationP Series PlexPower Distribution Panelboards Increased Safety
Applications The P Series PowerPlex panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Other
More informationSPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.
SPECIALTY PRODUCTS Flameproof housing Zones 1-2 and 21-22 to encase video cameras. Used for onshore and offshore sites and process supervision. Description Page Camera Housing eries Video Camera Housings
More informationPlexPower Factory Sealed Panelboard Increased Safety
Applications The IEC PlexPower factory sealed panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationPosition Switches Series 8070
www.stahl.de > Enclosures of type of protection "Increased safety > Dimensions and characteristic values according to EN 50041 > Replaceable contact in flameproof enclosure > Positive opening contacts
More informationFELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationMicro Limit Switch Series 8064
> For universal application > Versions with snap-action contact positive opening contact > With connecting cable or with single cores when it is used as a built-in device > Width Single limit switch 11
More informationGrounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071
www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or
More informationEx e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612
TECHNICAL DATA SHEET NEW PRODUCT Rev. 6-03/2013 Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612 Ex de Contact blocks SERIES M-0530, M-0531 1 - New Product Technical
More informationViamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations
Class I, Division, Groups A, B, C, D Class I, Zone, Group IIC Class II, Division, Groups F, G Zone, Group IIIB Type R,, X Applications For use in locations where: Flammable gases, vapors and dusts are
More informationATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationDECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A
X ECONTACTOR 20 A/32 A/63 A/125 A/200 A II2 G Ex de IIC, t 1 IP65 water-and dust-tight Integrated load-break switch Locking in connected or disconnected position by keying axis 178 X TECHNIL FEATURES X1
More informationProduct manual plug, sockets and coupler 16 A.- Z0251
Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationHazardous Location plug and receptacle
DX Hazardous Location plug and receptacle Main Advantages u u Rugged Construction, cost effective design Rated f Zone 1 and Zone 21 applications Features & Ratings p. 209 Certifications & Testing p. 210
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationLoad Disconnect Switches and Motor Switches
Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationEx Junction Boxes & Control Stations
www.fibox.com Ex Junction Boxes & Control Stations Fibox Oy Ab Keilaranta D Espoo, Finland Tel. + () Fax. + () E-mail: info@fibox.fi Homepage: www.fibox.com Fibox Ltd. -, Songdo-Dong, Yeonsu-Gu, Incheon,
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationINSTALLATION TECHNOLOGY MADE EASY
INSTALLATION TECHNOLOGY MADE EASY Pre-assembled branching/terminal boxes for Zone 1 and Zone 21 Each user can enjoy the benefits of the exlink with the pre-assembled branching boxes without having to first
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationLoads and Motor Switchgears
5 Loads and Motor Switchgears Motor Switches BLK Series Explosion-proof Motor Switches to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Class I, Zone 1 and Zone 2 Class I, Division
More informationXLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance
XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2
More informationControl Switches for Panel Mounting Series 8003
> Switch function many switching arrangements ( or spring-return) possible via coding easy change of the coding possible on site max. 2 pole > For > With flexible lead or spring cage terminal www.stahl.de
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationE2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the
More informationMake the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)
Make the Switch SPEEDY BUILD Rapid Run Service AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (0A - 150A) Your Specialist in CONTROL SOLUTIONS Contents 3. Surface Mounting IP65 Plastic
More informationControl Units Ex e in Stainless Steel LCS*.*
Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm
Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationLinear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2
> For use in hazardous areas with gas group IIB+H 2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationSolConeX Wall-Mounted Socket, 16 A
SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the
More informationTechnical Data. General specifications. Output type Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationThreaded thermocouple Miniature design Model TC10-D
Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationInstallation Sensing distance Connection Output configuration Operation mode NO Operation mode NC
Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationDISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw
DB DISCONNECTABLE MOTOR SWITCH AC-3 UP TO 45 kw 7.5 kw/22 kw/45 kw AC-3 visible switch for motors Standard IP66/IP67 Impact resistant metal casing - IK09 LOTO compliant 70 DB TECHNICAL FEATURES AC-3 motor
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationPush Buttons and Operator Interface New Product Catalog XAL Control Stations
Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104
More informationTechnical Data. Dimensions
Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationD5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S
D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1
More informationGrounding Monitoring Device Series 8485
www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - P O W E R C I R C U I T B R E A K E R S Up to 630 A CEAG power circuit breakers enable making or breaking of circuits under normal operating conditions as well as cutting in, briefly conducting and
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationM C. Ex d M-0... control, monitoring and signalling devices
Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationSafety switches with manual mechanical delay and separate actuator
Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS short knob 20 seconds MECHANICAL DELAY C L05 L L20 long
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationVibration Sensor Type 640
Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Instruction Manual English Instruction Manual Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Edition: 12.04.10 Attention! Before Start-Up
More informationEX- Documentation VA 450 / VA 452. thermal mass flow sensor
EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected plugs & receptacles Sicherheit, auf die Sie sich verlassen können Extended Temperature Range Ex-plugs & receptacles 16 A and 63 A for Zone 1 and 21 www.crouse-hinds.de EATON 2.1.1 in
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationContender LED Luminaires Enclosed and Gasketed Fixtures
Class I, Division, Groups A,B,C,D Class I, Zone, Group IIC Class II, Division, Groups E,F,G Zone and, Group IIIC Class II, Division, Groups F,G Type R, 4, 4X Applications Enclosed and gasketed fixtures
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationDECONTACTOR METAL 20 A/30 A/50 A/90 A
DN DECONTACTOR METAL 20 A/30 A/50 A/90 A IP55 automatic (IP66/67 optional) AC-22 and AC-23 Integrated Breaking Capacity (IEC/ EN 60947-3) Impact resistant metal casing - IK09 Suitable for heavy industry
More information