OMEGA Air Circuit Breakers
|
|
- Estella Jones
- 5 years ago
- Views:
Transcription
1 OMEGA
2 PWR O/L S/C INS EF NRL A RM L RPI OMEGA Salient features: Current rating from 400A to 600A in frames sizes Available in Pole/4 Pole, Manually & Electrically operated, Fixed / Draw-out version Common Height & Depth all across the range High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity 0A in Fr-1 & 600A in Fr- are the world s most compact air circuit breakers in terms of width & volume High mechanical and electrical operating life Neutral pole rating: %, 100% & 00% Available in both NRYB & RYBN configuration in 4 Pole ACBs In-built Electrical & Mechanical Anti-Pumping Complete range conform to IS / IEC & IEC Complete range is RoHS compliant Breaking Capacities : Icu = Ics = Icw Rated current Frame-1 Frame- Frame- N : ka S : ka H : ka S : ka H : ka H : ka V : 100kA 0A 1000A 1A 1600A 000A 0A 00A 4000A 00A 600A UW1-08 UW1-10 UW1-1 UW1-16 UW1-0 UW1-5 UW-08 UW-10 UW-1 UW-16 UW-0 UW-5 UW- UW-08 UW-10 UW-1 UW-16 UW-0 UW-5 UW- UW-40 UW- UW-6 Salient features: Unique breaker front-facia architecture displays the electrical accessories equipped on the ACB (with rated control voltage & type of operating voltage) Superior safety features - arc chute interlock, smart racking shutter, ready to close. Right aligned design to offer better utilization of space, especially in a multi-tier panel design Modular & snap-fit accessories such as UVR, SR, CR, redefine the modularity on time scale of 5 mins. Ease of on-site convertibility from Manual to Electrical & Fixed to Draw-out version Unipolar, snap-fit control terminals for independent termination of wires of up to.5 mm each ON & OFF buttons can be independently padlocked to prevent unauthorized access Racking shutter can be padlocked to prevent inadvertent racking operation Upto breakers can be mechanically interlocked using bowden cable. he Interlock is suitable for fixed, draw-out or a combination A1 OFF OFF A ON Shunt Release 0-40V~
3 1 4 NODE O/P 1 O/P O/P O/P 4 PWR MN RELAY I/P 1 I/P I/P I/P 4 PWR 1 4 NODE O/P 1 O/P O/P O/P 4 MN DIGIAL I/O O/P 1 O/P O/P O/P 4 PWR MN ANALOG O/P S-OU G-OU S-IN G-IN PWR MN ZSI SAUS RELAY PWR MN CS ES ALARM M.MODE PS CURREN DELAY MODE FREQ REF ES ALARM M.MODE PS CURREN DELAY MODE FREQ EL Matrix Protection & Control Unit Salient features: UW-MX 1.0/1.0G/1.5G UW-MX.5/.5G UW-MX.5/.5EC UW-MX 4.5 Available in 8 versions: MX1.0/1.0G/1.5G, MX.5/.5G, MX.5/.5EC & MX4.5 Unique O-LED display for wider viewing angle ouch Screen technology to provide ease in navigation Pluggable Communication & Power metering modules for customization & future upgradation Dual protection set-groups & Password protection Soft-rating plug for precise protection at lower load currents Local fault annunciation through LED indication & pre-trip alarm. rip & Event recording, Query button for last trip record. Front accessible test port. Provision for on-load self-diagnosis of releases Modbus, Profibus & Zigbee communication protocols Power & Harmonics measurement Easy to integrate with HMI & PLC Energy monitoring & control through Energy Management System Smart Card module for ease of parameterization Oscillographs to display pre & post fault current & voltage in MX4.5, helps to analyze system parameters Protection releases conform to EMI/EMC standard UW-MX.5/.5EC UW-MX 4.5 UW-PS Power Supply (4VDC) - Available in input versions (85-VAC; VDC) CAN BUS CAN BUS UW-REL Relay Output - 4 Prog. contacts of 40V/6A rating for closing, tripping, fault annunciation & maximum demand UW-AO Analog Output - 4 Analog output - Output Analog signals of 4-0mA/ 1-10 VDC UW-CS rip Circuit Supervision - Monitors healthiness of Shunt rip Circuit UW-EL Earth Leakage Protection - Range 0. to 0A - Needs specified external Cs UW-Digital Input/Output Digital I/O Module - 4 Isolated digital inputs - 4 Relay outputs UW-ZSI Zone Selective Interlocking - Intelligent discrimination for short circuit & earth fault UW-REF Restricted Earth Fault Protection - Detects zone of Earth fault - Needs specified external Cs UW-M emperature Rise Protection - Monitors breaker terminal temperature - Selectable temperature levels 0 (85 0 C to 115 C) - Mounted inside breaker
4 4 Matrix Protection & Control Unit Features Basic Protection Additional Protection rip Records Event Records Smart Card Communication Advance Protection Additional features Metering Storable settings ( sets) Auxiliary Supply (4 VDC) Parameter Overload - Phase Overload - Neutral Short Circuit Directional Short Circuit Instantaneous Earth Fault Current Voltage Frequency Reverse Power Maximum Demand Last 5 trip data Last 10 event data Modbus Profibus Zigbee (wireless) rip Circuit Supervision ( CS ) Zone Selective Interlocking (ZSI) emperature rise (M ) Earth Leakage ( EL ) Restricted Earth Fault ( REF ) Relay output Load Management Digital Input & Output Analog Output Current % Loading Voltage Power & Energy Harmonics * - available as optional. For detailed information please refer product literature. MX 1.0 MX1.0G MX1.5G MX.5 MX.5G MX.5 MX.5EC MX 4.5 * * * * * * * Simulation kit : Universal test kit for all versions of Matrix P&C Unit Generates phase current and voltage with adjustable phase angles Graphical display & smart GUI with multi functional key operation Portable & hand held device to simulate faults Dual Power ON - battery & external supply Auto sensing of P&C Unit connectivity Memory card for data storage upto GB Stores 10 test records PC interface through USB & Modbus OMEGA
5 5 OMEGA echnical details : Frame Rated Uninterrupted Current (In) (A) Version Rated Operational Voltage at /60 Hz. Ue Rated insulation voltage at /60 Hz. Ui Rated Impulse withstand voltage Uimp Suitability for Isolation Degree of Protection on Breaker front Pollution degree suitability Utilization Category Compliance Rating for 4th Pole Rated Ultimate S.C. Breaking Capacity Rated Service S.C. Breaking Capacity Rated Short ime Withstand Capacity Rated S.C. Making Capacity Opening ime (ms) Closing ime (ms) Mechanical Life Electrical Life Icu (ka) Ics (ka) 400/415V 0/5V 660/690V 400/415V 0/5V 660/690V 0.5sec. Icw (ka) 1.0sec..0sec. Icm (ka) 400/415V 0/5V 660/690V with maintenance with maintenance without maintenance N S 6 H 4 S H S H S H H V H V upto 690V 1000V 1kV (Main Circuit) Yes IP5 Intrinsic, IP54 available B IS/IEC (Part-), EN60947-, IEC % & 00% % & 100% % Icu * *00 for 1600 N&S version. Dimensional details : U-POWER Omega offers common depth (41mm) and height (4mm) across the entire range. 7 Frame 1 ** Poles 4# 4# 4# A Panel Door 16 Disconnected 5 est 5.5 A 41 # Dimensions for 100% N. Contact us for % N & 00% N. ** Depth of Frame- ACB will be 10mm additional with use of equalizer link. (All dimensions in mm)
6 Electrical Standard Products (ESP) Branch Offices: REGISERED OFFICE AND HEAD OFFICE L& House, Ballard Estate P. O. Box 78 Mumbai el: Fax: Website: ELECRICAL SANDARD PRODUCS (ESP) 1, Sakar Complex I Opp. Gandhigram Rly. Station Ashram Road Ahmedabad 009 el: Fax: esp-ahm@lnebg.com 8, Cubbon Road, P. O. Box 98 Bangalore el: /04 Fax: esp-blr@lnebg.com 11/1, Zone II Maharana Pratap Nagar Bhopal el: /7/ 8 / 9 Fax: esp-bho@lnebg.com Plot No. 9, Annapurna Complex Lewis Road Bhubaneswar el: , Fax: esp-bbi@lnebg.com SCO, Sector 6-D Madhya Marg, P. O. Box 14 Chandigarh el: , Fax: esp-chd@lnebg.com 10, Club House Road, Annasalai Chennai el: / 4 / 5 / 109 Fax: / esp-maa1@lntebg.com 67, Appuswamy Road Post Bag 7156 Opp. Nirmala College Coimbatore el: / 1 / 5 Fax: esp-cbe@lnebg.com L& House, Group MIG-5 Padmanabhpur Durg el: / 14 / 1 / 9 Fax: esp-durg@lnebg.com Khairasol, Degaul Avenue Durgapur 71 1 el: 9848, 9849, 9844 Fax: esp-dgp@lnebg.com Milanpur Road, Bamuni Maidan Guwahati el: / Fax: hazrasudipto@lnebg.com II Floor, Vasantha Chambers , Fateh Maidan Road Hyderabad 0004 el: Fax: esp-hyd@lnebg.com D-4, Prithvi Raj Road, C-Scheme Jaipur el: / 16 / 17 / 18 Fax: esp-jai@lnebg.com Akashdeep Plaza, nd Floor P. O. Golmuri Jamshedpur Jharkhand el: / 8 Fax: esp-jam@lnebg.com Skybright Bldg; M. G. Road Ravipuram Junction, Ernakulam Kochi el: / 4 / 5 / 7 Fax: esp-cok@lnebg.com -B, Shakespeare Sarani Kolkata el: / / 4 Fax: / esp-ccu@lnebg.com A8, Indira Nagar, Faizabad Road Lucknow el: / 5 / 6 Fax: esp-lko@lnebg.com No: 7, Karpaga Nagar, 8th Street K. Pudur Madurai 607 el: , Fax: esp-mdu@lnebg.com EBG North Wing Office-Level Gate 7, Powai Campus Mumbai el: / 77 / 1156 Fax: esp-bom@lnebg.com 1, Shivaji Nagar North Ambazari Road Nagpur el: / Fax: /0 esp-nag@lnebg.com, Shivaji Marg P. O. Box 6 New Delhi el: / 5 / 6 Fax: esp-del@lnebg.com L& House P. O. Box /1, Dhole Patil Road Pune el: / Fax: , esp-pnq@lnebg.com rd Floor Vishwakarma Chambers Majura Gate, Ring Road Surat el: Fax: esp-sur@lnebg.com Radhadaya Complex Old Padra Road Near Charotar Society Vadodara el: / 1 / Fax: esp-bar@lnebg.com , Dwarakanagar Visakhapatnam el: / Fax: esp-viz@lnebg.com Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here. Electrical Standard Products Larsen & oubro Limited Powai Campus, Mumbai Customer Interaction Center (CIC) BSNL / MNL (toll free) : Reliance (toll free) : el : Fax : cic@lnebg.com Website : SP
system of Air Circuit Breakers
OMEGA system of Air Circuit Breakers PWR O/L /C IN EF NRL ALRM RIP system of Air Circuit Breakers OMEGA L& s new range of compact air circuit breaker U-POWER Omega with next generation of Matrix Protection
More informationEnergy Saving HRC Fuse-Links
Energy Saving HRC Fuse-Links Blade Type HN 3 A - 800 A Cylindrical Type HF A - 3 A L&T, India's largest manufacturer of low tension switchgear, offers the new generation of low watt loss HRC fuse-links
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationIntelligent Power Factor Controller with Automatic set-up. etacon Series. Automatic Power Factor Controller
Intelligent Power Factor Controller with Automatic set-up etacon Series Automatic Power Factor Controller Trouble-free Power Factor Correction is now at your fingertips, thanks to the etacon series of
More informationProgrammable Logic Controllers. Type: LX
Programmable Logic Controllers Type: LX LX 7 Series Micro Logic Controller Features of LX7S Control 10, 14, 20, 28, 40, 48 digital I/O points 2 serial ports (1 RS-232C, 1 RS485 with RTU) Program memory
More informationOVERSEAS OFFICES OF L&T AND ITS SUBSIDIARIES AUSTRALIA JAPAN RUSSIA
Metering Solutions Larsen & Toubro (L&T) is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions, in the fields of Engineering, Construction,
More informationProgrammable Logic Controllers Type:LX
Programmable Logic Controllers Type:LX LX 7 Series Micro Logic Controller Features of LX7S Control 10,14,20,28,40,48 digital I/O points 2 serial ports (1 RS-232C, 1 RS485 with RTU) Program memory size
More informationDazzle. Designed to. Inspired by the beauty of India
DESIGNED FOR YOU Designed to Dazzle Inspired by the beauty of India Ethereal Beauty lies in the whole and soul of India. And we have woven the same kind of magic into entice. Its beautiful ribless design,
More informationMaximum Retail Prices
Maximum Retail Prices Effective from 01-01-2016 Presenting L&T s New Range of Distribution Boards Add an appeal to your wall with the state-of-art L&T s New Range of DISTRIBUTION BOARDS The Distribution
More informationMusic. for your. walls
Music for your walls What is music? The wave that soothes ruffled nerves. The expression that connects the detached. The beat of passion. The rhythm of love. Music is in solace. Music is in joy. There
More informationMOTOR PROTECTION RELAYS. for Total Peace of Mind
MOTO POTECTIO ELAS for Total Peace of Mind Switchgear Factory, avi Mumbai Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationNW08 to NW63 fixed circuit breakers Circuit breakers
fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationC60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationSoft Starters. For selection and product demonstration, please contact any of our branch offices listed below: L&T SWITCHGEAR L&T SWITCHGEAR
For selection and product demonstration, please contact any of our branch offices listed below: L&T SWITCHGEAR REGISTERED OFFICE AND HEAD OFFICE L&T House, Ballard Estate P. O. Box 278 umbai 400 001 Telephone:
More informationHigh-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay
High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationAppendix 08: Details of Location under Each Category
Appendix 08: Details of Location under Each Category Dated: Sr. No. A Bank Location CATEGORY - A Type of 1 Hyderabad - DR DR Site Telangana 2 Mumbai - DC DC Site 3 Mumbai- DC 4 Bangalore-
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationCANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID:
CONTACT DETAILS For any information/clarification/grievance on matters connected with NRIs, please contact our BRANCHES spread across the country: NRIs may also contact the following NRI Cells/Offices.
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationHuman Machine Interface
Human Machine Interface About us Larsen & Toubro infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation,
More informationAir Circuit Breaker (ACB)
MPACT Air Circuit Breaker (ACB) Rated from 0 to 000A the MPACT circuit breaker has been designed to meet the most stringent demands in fault detection and safe interruption thereof. Available in frame
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationThe art of simplicity. sentron
The art of simplicity Data Sheet sentron 3WT s Sentron 3WT The Art of Simplicity. During the last decade, with the introduction of 3WN and 3WL Circuit Breakers, Siemens introduced a new perspective in
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Current Voltage, Frequency Molded case (MCCB) Insulated Case (ICCB) 200
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More information100% electricity. Automatic transfer switch controllers ATL series
100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC
More informationDatasheet SRB301ST 24V (V.2)
26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationCommunication COM option in Masterpact
CT CCM modbus CD CE Functions and characteristics Communication COM option in 056431 056401 The COM option is required for integration of the circuit breaker or switch-disconnector in a supervision system.
More informationNew SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SXP200002B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
More informationDatasheet - SRB 301LC/B-24V
27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit
More informationVideo Door Phone Collection 2017
Door Phone Collection 2017 Safe Home with Crabtree Door Phone Add Security to your lifestyle Crabtree VDP products are designed and developed to the highest quality standards for individual residential
More informationLine A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.
Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationMiniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :
Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique
More informationFUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS
Line A Inverse parallel scrs Load a Line B COMPACT SCR POWER CONTROLLERS O delta Line c inverse parallel scrs Load C 1 Compact Brochure Rev 3.51 www.ccipower.com 1-800-765-2799 FEATURES Auto-Ranging Input
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationLV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue
LV power circuit breaker and switch-disconnectors Masterpact NW Direct current 1000 to 4000 A Catalogue 2002 Get more with the world s Power & Control specialist Masterpact NW General contents Presentation
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationATS Automatic transfer switches Advanced version
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationEnhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades
Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades May 2012 / 1910DB1202 by Hal Theobald, Product Manager, Schneider Electric Services and Reza Tajali, P.E.,
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationNewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators
NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator
More informationASCO SERIES 230 Automatic Transfer Switch
ASCO SERIES 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230
More informationSoft starter- ASAB 1
Soft starter- ASAB 1 ASAB-Series Soft starter Soft start/stop static starters for three-phase asynchronous motors. The ASAB is an advanced digital soft start solution for motors from 7 kw to 800 kw. ASAB
More informationDIRIS A-30 Multifunction power metering & monitoring device - PMD
Single-circuit metering, measurement & analysis The solution for > Industry > Building > Infrastructures diris_986_a_us.psd Strong points Function The is a power metering and monitoring device that provides
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More informationComprehensive Feeder Protection FCOMP FEEDER CONTROL METERING PROTECTION RELAY
Comprehensive Feeder Protection FCOMP FEEDER CONTROL METERING PROTECTION RELAY Larsen & Toubro (L&T) is a technology-driven company that infuses engineering with imagination. The Electrical & Automation
More informationFeeder protection relay SPAA 121 C. Product Guide
Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationDatasheet - AZM300Z-ST-1P2P-A
08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs
More informationTECHNICAL DESCRIPTION
MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up
More informationDatasheet - MZM 100 B ST2-1P2PW2RE-A
19.03.2014-11:42:51h Datasheet - MZM 100 B ST2-1P2PW2RE-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationPowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006
PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical
More information4. CIRCUIT BREAKERS. Functional Emergency Switching
4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationLE ELECTRONICS Pvt. Ltd.
LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationSeries 2400 Paralleling Switchgear
Series 2400 Paralleling Switchgear SERIES 2400 PARALLELING SWITCHGEAR TYPICAL SERIES 2400 MULTIPLE GENERATOR/UTILITY PARALLELING SWITCHGEAR Intelligent, Configurable Switchgear for Distributed Generation,
More informationYour process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this
Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,
More informationDatasheet - MZM 100 B ST-1P2PW2REM-A
19.07.2016-15:57:28h Datasheet - MZM 100 B ST-1P2PW2REM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationFLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.
CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS
More informationMV Network Switchgear, Protection and Control
MV Network Switchgear, Protection and Control Ravinder Negi Manager, Services Execution INDIA Schneider Electric, New Delhi. Agenda An Overview MV Network Basic Definitions Circuit breaker Switchgear Control
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationE1 Plus Electronic Overload Relay
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations
More informationSeries 230 Automatic Transfer Switch
Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationCDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA
Application Applied to power distribution of AC Hz/60Hz, rated operational voltage 400/ 690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationSMART WIREFREE. Home Automation Solutions
Home Automation Solutions Collection 2017 What is Home Automation? Home automation systems are designed to make a home owners life more comfortable, convenient and secure. With a range of solutions available
More informationPEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers
Virtual Branch ecatalogue click here controllers HVAC/R controllers The PEAK 18 and PEAK 32 Controllers are configurable controllers that can be switched between MS/TP, Modbus RTU, and N2 Communication
More informationDatasheet - AZ 16-03ZVRK
23.07.2015-02:06:20h Datasheet - AZ 16-03ZVRK Safety switch with separate actuator / AZ 16 Preferred typ Thermoplastic enclosure Double-insulated Large wiring compartment 52 mm x 90 mm x 30 mm Multiple
More informationModel: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model: KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More information