E-Series and EF-Series Systems

Size: px
Start display at page:

Download "E-Series and EF-Series Systems"

Transcription

1 E-Series and EF-Series Systems Controller Upgrade Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S. Telephone: +1 (408) Fax: +1 (408) Support telephone: +1 (888) Web: Feedback: Part number: _A0 November 2015

2

3 Table of Contents 3 Contents Upgrading or replacing all controller canisters in a controller-drive tray... 4 Cabling considerations for controller-drive tray hardware upgrades... 8 Preparing to replace the controllers Removing controller canisters from a controller-drive tray Installing new controller canisters in the controller-drive tray Powering on the storage array Remounting volumes after changing the vendor from lsi to NETAPP Remounting volumes on a Windows host Steps for AIX hosts Remounting volumes on a VMware host Copyright information Trademark information How to send comments about documentation and receive update notifications... 31

4 4 Upgrading or replacing all controller canisters in a controller-drive tray About this task Use these procedures to replace all of the controllers in a controller-drive tray. You typically use these procedures when you choose to upgrade all of the controllers to a different model or platform. You might also use these procedures in the following situations: When all controllers in a controller-drive tray encounter hardware failures and are no longer functional. To upgrade the dual inline memory modules (DIMMs) in your controller-drive tray by replacing both controllers with the same model of controllers, but with different DIMMs. If you are upgrading the host interface cards (HICs) in your controller-drive tray by replacing both controllers with the same model of controllers, but with different HICs, refer to the applicable flyer for upgrade instructions: Replacing a Controller Canister in the E5560 Controller-Drive Tray to Replace a Failed Host Interface Card Replacing a Controller Canister in the E5512 or the E5524 Controller-Drive Tray to Replace a Failed Host Interface Card If you are upgrading the HICs in your controller-drive tray to 56-Gb/sec InfiniBand (IB) HICs, you can use procedures in the following document to convert the protocol of the new HIC from iscsi Extensions for Remote Direct Memory Access (iser) to Secure Remote Password (SRP). Converting an InfiniBand HIC from iser to SRP You can upgrade an E5400 storage array or an EF540 flash array that has Fibre Channel base ports and two-port iscsi HIC by installing new E5600 or EF560 controllers that have four-port HICs. You can then apply a feature pack in SANtricity Storage Manager to configure the HICs to operate with two iscsi ports and two Fibre Channel ports (Fibre Channel-iSCSI split mode). You can use the procedures in the following document to perform this upgrade. Upgrading E5400 or EF540 Controllers to E5600 or EF560 Controllers when Using Fibre Channel-iSCSI Split Mode For duplex controller-drive trays, you replace both controllers. For simplex controller-drive trays, you replace the one controller. In both cases, you must power off the controller-drive tray. As a result, you cannot access data on the storage array until you successfully complete the replacement. If your storage array participates in remote volume mirroring, only iscsi or Fibre Channel connections are supported between the primary site and the remote site. If the HIC configuration in your new controllers does not include iscsi or Fibre Channel connections, remote volume mirroring will not be supported. For Asynchronous Mirroring, the local storage array and remote storage array can run different versions of firmware. The minimum firmware version supported is SANtricity firmware version If you order a new controller, it will normally be shipped without a battery installed. When possible, you should remove the battery from your old controller and then install that battery in the new controller. However, for some controller upgrades, the battery from the old controller is not compatible with the new controller. In those cases, you must order a battery along with your new controller, and have that battery available before you begin these tasks.

5 Upgrading or replacing all controller canisters in a controller-drive tray 5 Some controller upgrades result in the Vendor ID in SCSI Inquiry Data changing from LSI to NETAPP. When the Vendor ID changes from LSI to NETAPP, additional steps are required on the Windows, VMware, and AIX operating systems to reclaim devices. Steps for these operating systems are included in this document. If you are replacing the controllers to upgrade to a new model, keep in mind that your current storage array might have premium features installed that the new model cannot support. For example, E2700 controllers do not support the legacy Snapshot premium feature. If you replace E2600 controllers with E2700 controllers, and your storage array was using the legacy Snapshots feature, you must disable that feature and delete or convert all volumes (that is, snapshots, repositories) associated with that feature before you replace the controllers. You can convert legacy Snapshots to Snapshots. Before you upgrade a controller-drive tray, you should disable any premium features used on your storage array that are not supported on the new controllers. If you change your controllers from 5x00 models to 2x00 models, your new storage array configuration will support lower numbers of some objects (for example, volumes) in the storage management software than your old configuration. You must make sure that your old configuration does not exceed the object limits listed below before you replace the controller(s). Maximum number of volumes Maximum number of partitions Maximum number of snapshot volumes Maximum number of member volumes per consistency group - 32 Maximum number of consistency groups - 16 Maximum number of views Maximum number of legacy RVM mirrors - 16 Maximum number of ARVM mirrors - 32 Maximum number of ARVM mirrors per mirror group - 32 Maximum total number or mirrors (Legacy RVM + ARVM) - 32 Maximum number of volume copies Maximum number of thin provisioned volumes Maximum number of drive slots in the storage array (controller-drive tray + all attached drive trays) - 192

6 6 To E2x00 To E5x00 To EF5x0 From E2x00 Battery - Reuse the old battery Vendor ID - Additional steps required Feature Support - Legacy snapshots are not supported on the E2700 Battery - Order a new battery Vendor ID - Additional steps are required when upgrading from E2600 to E5500 or E5600, or when upgrading from E2700 to E5400 Upgrades are not supported Feature Support - Legacy snapshots are not supported on the E5500 or E5600 Legacy RVM is not supported on the E5500 or E5600 with iscsi HICs Data Assurance is not supported on the E5500 or E5600 with iscsi HICs From E5x00 Battery - Order a new battery Vendor ID - Additional steps are required when upgrading from E5500 or E5600 to E2600, or when upgrading from E5400 to E2700 Feature Support - Legacy snapshots are not supported on the E2700 Battery - Reuse the old battery Vendor ID - Additional steps required when upgrading from E5400 to E5500 or E5600 Feature Support - No legacy snapshots for E5500 or E5600 No legacy RVM or Data Assurance for E5400/ E5500 with iscsi HICs Upgrades are not supported From EF5x0 Upgrades are not supported Upgrades are not supported Battery - Reuse the old battery Vendor ID - Additional steps required when upgrading from EF540 to EF550 or EF560 Feature Support - No Legacy Snapshots for EF550/EF560 No Data Assurance for EF550/EF560 with iscsi Attention: Possible loss of data access Before you replace the controllers, make sure that any premium features that are installed and any configuration of objects in the storage management software can be supported with your new controllers. Failure to do this will result in an out-ofcompliance condition or configuration errors. Contact technical support if you encounter configuration errors. Attention: Possible loss of data access Before you replace the controllers, upgrade your storage array to the latest version of the operating system (controller firmware), if possible. Normally, you will upgrade the new controllers to the latest version of the operating system after you install them. If you are not able to upgrade the existing controllers to version or later, then, after you

7 Upgrading or replacing all controller canisters in a controller-drive tray 7 install the replacement controllers, you must install an operating system version on them to match (same major version) what was installed on the old controllers. Contact technical support for assistance in making this determination. Attention: Possible loss of data access If any controller that you are replacing manages any secure volumes, the new controller needs the correct security key to manage those volumes. After you replace the controller and restore power to the controller-drive tray, you can use SANtricity Storage Manager to load the key from the file in which it was saved. Be sure that such a file exists and that you know the pass phrase required to install the security key before you replace the controller. To complete this procedure, you will need antistatic protection and one or two new controller canisters. You might also need new controller batteries. If your new controller canisters do not have the same host interface cards as the controller canisters you are replacing, you might need new host bus adapters, cables and Small Form-factor Pluggable (SFP) transceivers to re-cable your host connections. If the new controller canisters support different drive cabling from the old controller canisters, you might also need different drive cables.

8 8 Cabling considerations for controller-drive tray hardware upgrades Compare your current host cabling to the supported cabling for your new controllers to determine whether you can reuse SFPs, QSFPs or cables from your old cabling configuration. The HBAs, HCAs, or Ethernet adapters, as well as switches in the network fabric used to connect your hosts to your storage array must match the HICs in your controller canisters. Supported cables for E5500 and E5600 controller-drive trays and the EF550 and EF560 flash arrays HIC Data Rate and Protocol Number of Connectors Cable Connector Type Length 12 Gb/s SAS 4 MiniSAS-HD passive copper 1-5m MiniSAS-HD active copper 8-15m MiniSAS-HD optical 5-100m Fan-out cable type #2 Fan-out cable type #3 passive copper passive copper 6 Gb/s SAS 4 MiniSAS-HD passive copper 1-10m 2m 2m MiniSAS-HD active copper 5-20m Fan-out cable type #1 passive copper 56 Gb/s InfiniBand 1 2 QSFP+ passive copper 1-3m 2m QSFP+ optical 5-100m 40 Gb/s InfiniBand 2 2 QSFP+ passive copper 1-5m 16 Gb/s Fibre Channel QSFP+ optical m 4 SFP+ OM2 SW optical 2, 3, 5, 10, 25m SFP+ OM3 SW optical m SFP+ OS2 LW optical m 10 Gb/s iscsi 4 SFP+ OM2 optical 2, 3, 5, 10, 25m SFP+ OM3 optical m Twin-Ax passive copper 2-7m

9 Cabling considerations for controller-drive tray hardware upgrades 9 HIC Data Rate and Protocol Number of Connectors Cable Connector Type Length 1 Gb/s iscsi 4 SFP+ 3 OM2 optical 2, 3, 5, 10, 25m SFP+ 3 OM3 optical m Twin-Ax passive copper 2-7m RJ-45 4 passive copper 2-70m 1 This information applies to HICs with a maximum data rate of 56 Gb/s. These HICs can also be operated at 40 Gb/s. 2 This information applies to HICs with a maximum data rate of 40 Gb/s. These HICs can also be operated at 20 Gb/s. These HICs can be used only in the E5500 and EF550 models. 3 Optical cables for 1-Gb/s iscsi connections require a 1-Gb/s SFP. 4 Copper cables with RJ-45 connectors for iscsi connections require an SFP adapter. Supported cables for E2700 controller-drive trays HIC Data Rate and Protocol Number of Connectors Cable Connector Type Length 12 Gb/s SAS 4 MiniSAS-HD passive copper 1-5m 16 Gb/s Fibre Channel MiniSAS-HD active copper 8-15m MiniSAS-HD optical 5-100m 2 MiniSAS-HD passive copper 1-5m MiniSAS-HD active copper 8-15m MiniSAS-HD optical 5-100m 4 Fan-out cable type #2 Fan-out cable type #3 passive copper passive copper 4 SFP+ OM2 SW optical 2,3,5,10,25 m 2m 2m SFP+ OM3 SW optical m SFP+ OS2 LW optical m 2 SFP+ OM2 SW optical 2,3,5,10,25 m SFP+ OM3 SW optical m SFP+ OS2 LW optical m

10 10 HIC Data Rate and Protocol Number of Connectors Cable Connector Type Length 10 Gb/s iscsi 4 SFP+ OM2 optical 2,3,5,10,25 m SFP+ OM3 optical m Twin-Ax passive copper 2-7m 2 SFP+ OM2 optical 2,3,5,10,25 m SFP+ OM3 optical m Twin-Ax passive copper 2-7m RJ-45 Cat6a passive copper 2-100m 1 Gb/s iscsi 4 SFP+ 1 OM2 optical 2, 3, 5, 10, 25m SFP+ 1 OM3 optical m Twin-Ax passive copper 2-7m RJ-45 2 passive copper 2-70m 2 SFP+ 1 OM2 optical 2, 3, 5, 10, 25m SFP+ 1 OM3 optical m Twin-Ax passive copper 2-7m RJ-45 2 Cat5 passive copper 2-70m RJ-45 Cat6a passive copper 2-100m 1 Optical cables for 1-Gb/s iscsi connections require a 1-Gb/s SFP. 2 Copper cables with RJ-45 connectors for iscsi connections require an SFP adapter.

11 11 Preparing to replace the controllers Steps 1. Make sure that the existing storage array is updated to the latest released operating system (controller firmware) version. Note: If you are not able to upgrade the existing storage array to the latest version, keep a record of the current version. You will need to make sure that the operating system version on the new controllers you install matches the version that you are replacing. 2. If the Drive Security feature is enabled and a security key exists on the storage array, follow these steps to save the key: a. Go to the Array Management Window. b. From the Storage Array menu, select Security > Drive Security > Save Key. c. Save the security key to a location not on the storage array. 3. Perform the following steps to record the serial number for your storage array: a. In the EMW tree view, double-click your storage array. The AMW opens. b. In the Summary tab of the AMW, click the View Storage Array Profile link. c. Make a record of the value for Chassis Serial Number. You need this serial number to perform the steps in "Powering on the storage array." 4. Gather support data about your storage array by using one of these methods: Use the storage management software to collect and save a support bundle of your storage array. From the Array Management Window toolbar, select Monitor > Health > Collect Support Data Manually. Then name and specify a location on your system where you want to store the support bundle. Use the command line interface (CLI) to run the save storagearray supportdata command to gather comprehensive support data about the storage array. For more information about this command, refer to the current version of the Command Line Interface and Script Commands Programming Guide. Note: Gathering support data can temporarily impact performance on your storage array. 5. Ensure that no I/O operations are occurring between the storage array and all connected hosts. For example, you can perform these steps: Stop all processes that involve the LUNs mapped from the storage to the hosts. Ensure that no applications are writing data to any LUNs mapped from the storage to the hosts. Unmount all file systems associated with volumes on the array. Note: The exact steps to stop host I/O operations depend on the host operating system and the configuration, which are beyond the scope of these instructions. If you are not sure how to stop host I/O operations in your environment, consider shutting down the host.

12 12 Attention: Possible data loss If you continue this procedure while I/O operations are occurring, you might lose data. 6. If the storage array participates in a mirroring relationship, stop all host I/O operations on the secondary storage array. 7. Wait for five minutes to allow any data in cache memory to be flushed to disk. 8. In the Hardware tab of the Array Management Window, select the graphic representation of the storage array, and then select Monitor > Reports > Operations in Progress. 9. Wait for all operations shown on the Operations in Progress window to complete before continuing with the next step. 10. Turn off power to the controller-drive tray. 11. Wait for all of the LEDs on the controller-drive tray to go dark. 12. Turn off power to each drive tray that is connected to the controller-drive tray. 13. Wait for two minutes for all of the drives to spin down. Related tasks Powering on the storage array on page 22

13 13 Removing controller canisters from a controllerdrive tray About this task Attention: Possible hardware damage To prevent electrostatic discharge damage to the tray, use proper antistatic protection when handling tray components. Steps 1. Put on antistatic protection. Attention: Potential degraded performance To prevent degraded performance, do not twist, fold, pinch, or step on the cables. Many cables have a minimum bending radius. Check the specifications for your cables, and do not bend any cable tighter than the minimum specified radius. 2. Label each cable that is attached to the old controller canister. Depending on the HIC configuration, you might be able to reconnect some cables after you replace the controller canister. 3. Disconnect all of the interface and Ethernet cables from the old controller canister. If fiber-optic cables are present, you can use the two release levers to partially remove the controller canister. Opening these release levers makes it easier to press down the fiber-optic cable release tab. 4. If the old controller canister contains a Fibre Channel HIC or an InfiniBand HIC, remove the small form-factor pluggable (SFP+) transceivers (for Fibre Channel) or quad SFP (QSFP+) transceivers (for InfiniBand) from the HIC, and save them for possible reuse. 5. Remove controller A. a. Unlock and rotate the release handles out to release the controller canister. b. Using the release handles and your hands, pull the controller canister out of the controllerdrive tray. The following figures show the release handles for the E2612 and E2624 controller-drive trays and the E2660 controller-drive tray. The other controller-drive trays have a similar configuration for the release handles.

14 14 Removing a controller canister from the E2612 or the E2624 controller-drive tray 1. Release Handles 2. Controller Canisters Removing a controller canister from the E2712 or the E2724 controller-drive tray

15 Removing controller canisters from a controller-drive tray Release Handles 2. Controller Canisters Removing a controller canister from the E2660 controller-drive tray 1. Release Handles 2. Controller Canisters

16 16 Removing a controller canister from the E2760 controller-drive tray 1. Release Handles 2. Controller Canisters

17 Removing controller canisters from a controller-drive tray 17 Removing a controller canister from the E5400, EF540, E5500, or EF550 controller-drive tray Release Handles 2. Controller Canisters

18 18 Removing a controller canister from the E5460 or E5560 controller-drive tray 1. Release Handles 2. Controller Canisters 6. Set the old controller canister on a flat, static-free surface near the controller-drive tray with the release levers up. Position the controller canister so that you can access the top cover. 7. Choose one of the following options: If you will reuse the battery from the old controller in the new controller, continue with step 8 on page 18. If you will install a new battery in the new controller, go to step 11 on page Press down on both of the top cover latch buttons on the old controller canister, and slide the top cover to the rear of the canister. 9. Perform one of the following options, depending on your model of controller-drive tray, to release the old battery: For the E2600 controller-drive tray or the E2700 controller-drive tray, unscrew the thumb screw that secures the battery to the controller canister. For the E5400 controller-drive tray, the EF540 controller-drive tray, the E5500 controller-drive tray, the EF550 controller-drive tray, the E5600 controller-drive tray, or the EF560 controllerdrive tray, release the tab that secures the battery to the controller canister. 10. Remove the battery by sliding it towards the rear of the old controller canister.

19 Removing controller canisters from a controller-drive tray For a duplex controller-drive tray, repeat step 2 on page 13 through step 10 on page 18 for the second controller canister.

20 20 Installing new controller canisters in the controller-drive tray About this task Perform the following steps for each controller in the controller-drive tray. Steps 1. Unpack a new controller canister. a. Set the new controller canister on a flat, static-free surface near the controller-drive tray with the top cover up. b. Save all of the packing materials so that you can, if necessary, ship the old controller canister. 2. Push down the two top cover latch buttons that secure the top cover to the new controller canister. 3. Remove the top cover by sliding it to the rear of the new controller canister. 4. Are you installing the battery in an E2600 controller-drive tray or an E2700 controller-drive tray? Yes For an E2600 controller-drive tray or an E2700 controller-drive tray, go to step 9 on page 20. No Continue with the next step. 5. Insert the battery (either the new battery that you ordered or the battery that you removed from the old controller canister) into the new controller canister. Slide the battery into the canister, making sure it stays below the rivets on the wall of the new canister. 6. Keeping the locking handle at a 45 degree angle, align the connectors at the bottom of the battery with the connectors on the canister. 7. Push the battery down until you hear it click, and move the locking handle up to secure the controller battery to the controller canister. Attention: To make sure that the controller battery is seated correctly in an E5400 controllerdrive tray, an E5500 controller-drive tray, an E5600 controller-drive tray, an EF540 controllerdrive tray, an EF550 controller-drive tray, or an EF560 controller-drive tray, you might need to slide it out and insert it again. You will know it is secure when you hear it click into place, and when the locking handle does not move out of its upright position when you wiggle it. 8. Go to step 11 on page Insert the battery circuit board (either the new battery circuit board that you ordered or the battery circuit board that you removed from the old controller canister) by sliding it towards the front of the new controller canister. Note: To ensure that the battery is seated correctly in an E2600 controller-drive tray or an E2700 controller-drive tray, you might need to back it out of the connector to make sure that it is correctly aligned with the thumbscrew. 10. Tighten the thumbscrew to secure the battery circuit board in the new controller canister card. 11. Reinstall the top cover on the new controller canister by sliding it forward until the top latch covers click. 12. Slide the new controller canister all the way into the controller-drive tray. Rotate the release levers towards the center of the controller canister to lock it into place.

21 Installing new controller canisters in the controller-drive tray If your new controller canister has a Fibre Channel HIC or an InfiniBand HIC, install the SFP+ transceivers (Fibre Channel) or QSFP+ transceiver (InfiniBand) into the controller canister. Depending on the HICs involved in your upgrade, you might be able to reuse SFP+ transceiver or QSFP+ transceivers that you removed from your old controller canister. See Cabling considerations for controller-drive tray hardware upgrades on page 8 for details about cabling requirements. 14. Reconnect all of the cables between the controller-drive tray and the drive trays. Note: If you are upgrading to E2700 controllers from an earlier model, the drive cabling configuration might be different from the configuration used for the old controllers. If the drive cabling configuration is the same as it was with your old controllers, use the labels that you attached to the cables to reconnect the cables correctly.

22 22 Powering on the storage array About this task Note: If the controller upgrade involves a protocol change (for example, Fibre Channel to iscsi), any hosts groups, hosts, and volume-to-lun mappings defined in the host mappings tab remain intact. However, you must take steps to associate the new host ports with the hosts. If the controller upgrade does not involve a protocol change, all host port mappings will remain intact and no additional steps are required. Steps 1. Turn on the Power switch on the rear of each drive tray that is connected to the controller-drive tray. 2. Wait two minutes for the drives to spin up. 3. Turn on the Power switch on the rear of the controller-drive tray. 4. Wait three minutes for the power-up process to complete. 5. If you saved a Drive Security key in Preparing to Replace the Controllers on page 11, perform the following steps on each controller to import that key. a. If there is a mix of secured and unsecured drives in the storage array, create a new Drive Security key. Unsecured drives are unassigned drives, GHS drives, or drives which are part of a volume group or a disk pool that is not secured by Drive Security. Secured drives are assigned drives which are a part of a secured volume group or Disk Pool using Drive Security. b. Import the Drive Security key that you saved in Preparing to Replace the Controllers on page 11. (From the Storage Array menu, select Security > Drive Security > Import Key.) c. If there were only secured drives (no unsecured drives) in the storage array, the controller(s) will automatically reboot to complete the import operation. Wait for all controllers to boot up. When a controller finishes booting, its icon will appear in the Enterprise Management Window (EMW). 6. If the Drive Security feature is enabled, and the storage array has a mix of secured and unsecured drives, follow these steps: a. Run the set alldrives nativestate SMcli command. b. Reset all controllers using SANtricity Storage Manager. c. Wait for all controllers to boot up. When a controller has finished booting, it appears in the EMW. 7. Look at the LEDs on controller A to make sure that it is booting correctly. The Host Link Service Action Required LEDs turns green during the reboot. The seven-segment display shows the sequence OS+ Sd+ blank- to indicate that the controller is performing Start-ofday (SOD) processing. After the controller successfully completes rebooting, the seven-segment display shows the tray ID matching the seven-segment display on the second controller. You can then discover the new controller canister by using the storage management software.

23 Powering on the storage array 23 Controller LEDs and seven segment display on the E5500, EF550, E5600 and EF560 controller-drive trays 1. Controller Service Action Allowed LED (Blue) 2. Controller Service Action Required LED (Amber) 3. Seven-Segment Display 4. Host Link 1 Service Action Required LED (Amber 5. Host Link 2 Service Action Required LED (Amber) 6. Host Link 3 Service Action Required LED (Amber) 7. Host Link 4 Service Action Required LED (Amber) Controller LEDs and seven segment display on the E5400 controller-drive tray 1. Controller Service Action Allowed LED (Blue) 2. Controller Service Action Required LED (Amber) 3. Seven-Segment Display 4. Host Link 1 Service Action Required LED (Amber 5. Host Link 2 Service Action Required LED (Amber) 6. Host Link 3 Service Action Required LED (Amber) 7. Host Link 4 Service Action Required LED (Amber)

24 24 Controller LEDs on the E2600 controller-drive tray Host Link 1 Service Action Required LED (Amber) 2. Host Link 2 Service Action Required LED (Amber) 3. Battery Service Action Required LED 4. Controller Service Action Allowed LED (Amber) 5. Controller Service Action Required LED (Amber) Controller LEDs and seven segment display on the E2700 controller-drive trays 1. Controller Service Action Allowed LED (Blue) 2. Controller Service Action Required LED (Amber) 3. Seven-Segment Display 8. Perform these steps if any of the controller-drive tray s Service Action Required LEDs are on, or if the Controller Service Action Required LED is on: a. Check that the controller canister has been installed correctly and that all of the cables are correctly seated. Reinstall the controller canister, if necessary. b. Check the controller-drive tray s Service Action Required LEDs and the Controller Service Action Required LED again. If the problem is not corrected, contact technical support. 9. For a duplex configuration, repeat step 7 on page 22 through step 8 on page 24 for controller B.

25 Powering on the storage array Using the LEDs and the storage management software, check the status of all of the trays in the storage array. 11. Does any component have a Needs Attention status? Yes Click the Recovery Guru toolbar button in the Array Management Window, and complete the recovery procedure. If the problem is not resolved, contact technical support. No Go to step 12 on page Remove the antistatic protection. 13. Perform the appropriate action from the following choices to make sure that your new controllers are running with the correct operating system (controller firmware) level. If you were not able to upgrade the original controllers to the most recent operating system version, make sure that the version running on the new controllers matches the version that ran on the original controllers. If necessary, install the appropriate version on the new controllers. If you were able to upgrade the original controllers to the most recent operating system version, make sure that the latest version is also running on the new controllers. If necessary, install the latest version on the new controllers. 14. If your controller upgrade involves a protocol change (for example, Fibre Channel to iscsi), and you already have hosts defined for your storage array, perform the following steps to associate the new host ports with your hosts: a. In the Array Management Window, select the Host Mappings tab. b. From the Storage Array tree on the left of the window, select the host to associate with a port. c. From the Array Management Window toolbar, select Host Mappings > Manage Host Port Identifiers. d. To update the host port identifier information associated with each host, replace the host port IDs from the old host adapters with the new host port IDs for the new host adapter. e. Repeat step d for each host. 15. Gather support data about your updated storage array by using one of these methods: Use the storage management software to collect and save a support bundle of your storage array. From the Array Management Window toolbar, select Monitor > Health > Collect Support Data Manually. Then name and specify a location on your system where you want to store the support bundle. Use the CLI to run the save storagearray supportdata command to gather comprehensive support data about the storage array. For more information about the CLI command, refer to the current version of the Command Line Interface and Script Commands Programming Guide. Note: Gathering support data can temporarily impact performance on your storage array. 16. Perform the following steps to open a non-technical case with NetApp Technical Support. This action alerts NetApp Technical Support to the changes that you made to the configuration of your storage array. a. Get the serial number of the controller-drive tray that you recorded in Preparing to replace the controllers on page 11. b. Go to the NetApp support site at mysupport.netapp.com/eservice/assistant.

26 26 c. If the Login page appears, enter your username and password, and select Login. The Give Us Feedback page opens. d. Select Product Registration from the drop-down list under Category 1. e. Enter the following text in the Comments text box, substituting the serial number of your controller-drive tray for serial number: Please create alert against Serial Number: serial number. The alert name should be E-Series Upgrade. The alert text should read as follows: Attention: The controllers in this system have been upgraded from the original configuration. Verify the controller configuration before ordering replacement controllers and notify dispatch that the system has been upgraded. f. Click the Submit button at the bottom of the form.

27 27 Remounting volumes after changing the vendor from lsi to NETAPP About this task If your controller upgrade results in changing the vendor ID from LSI to NETAPP, you must take steps on each Windows, VMware or AIX host that uses volumes from the updated storage array. Refer to the task for the corresponding operating system on each host. Remounting volumes on a Windows host Steps 1. In the Device Manager, select Show Hidden Devices. 2. For each NETAPP SCSI Disk Device listed in the Device Manager, right-click on the entry and select Uninstall. If Windows displays a dialog with a message indicating that you should reboot the host, finish uninstalling all of the volumes before you scan for hardware and reboot. 3. Right-click in the Device Manager and select Scan for Hardware Changes. 4. Reboot the host. Steps for AIX hosts About this task After you replace the controllers, you might observer that host shows the new volumes on the storage array, but also shows the original volumes as failed.if failed volumes appear, perform the following steps. Step 1. From the command line, run the cfgmgr command. Remounting volumes on a VMware host About this task After you replace the controllers, you might observe the following conditions: VMware shows new paths for the volumes on the storage array, but also shows the original paths as dead paths. The hosts still list the volumes on the storage array as having LSI vendor IDs. This might occur when the volumes were claimed by the LSI rule at the start and so continue to use the same LSI rule when the volumes come back on line. The Display Name does not reflect the change from LSI to NetApp. This might occur because the display name became free test after initial discovery. In this case, you can change the Display Name manually.

28 28 If dead paths appear, perform the following steps. Steps 1. Perform a rescan on the each host. 2. Halt all host I/O operations to this subsystem. 3. To reclaim the volumes under NetApp rule, perform the following steps. a. From the command line, run the esxcli storage core device list command. Check the output from the command to identify volumes whose names have the form aa.xxxx. b. From the command line, run the command do esxcli storage core claiming reclaim -d naa.xxxxx to change the LSI vendor ID to NetApp.

29 29 Copyright information Copyright NetApp, Inc. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS (October 1988) and FAR (June 1987).

30 30 Trademark information NetApp, the NetApp logo, Go Further, Faster, AltaVault, ASUP, AutoSupport, Campaign Express, Cloud ONTAP, Clustered Data ONTAP, Customer Fitness, Data ONTAP, DataMotion, Fitness, Flash Accel, Flash Cache, Flash Pool, FlashRay, FlexArray, FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexVol, FPolicy, GetSuccessful, LockVault, Manage ONTAP, Mars, MetroCluster, MultiStore, NetApp Insight, OnCommand, ONTAP, ONTAPI, RAID DP, RAID-TEC, SANtricity, SecureShare, Simplicity, Simulate ONTAP, Snap Creator, SnapCenter, SnapCopy, SnapDrive, SnapIntegrator, SnapLock, SnapManager, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapValidator, SnapVault, StorageGRID, Tech OnTap, Unbound Cloud, and WAFL and other names are trademarks or registered trademarks of NetApp, Inc., in the United States, and/or other countries. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. A current list of NetApp trademarks is available on the web at

31 31 How to send comments about documentation and receive update notifications You can help us to improve the quality of our documentation by sending us your feedback. You can receive automatic notification when production-level (GA/FCS) documentation is initially released or important changes are made to existing production-level documents. If you have suggestions for improving this document, send us your comments by to To help us direct your comments to the correct division, include in the subject line the product name, version, and operating system. If you want to be notified automatically when production-level documentation is released or important changes are made to existing production-level documents, follow Twitter You can also contact us in the following ways: NetApp, Inc., 495 East Java Drive, Sunnyvale, CA U.S. Telephone: +1 (408) Fax: +1 (408) Support telephone: +1 (888)

Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray

Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray E-Series Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray To replace a failed E2700 controller canister in a duplex configuration, you remove the controller canister from the E2760

More information

Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays

Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays E-Series Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays The Recovery Guru in SANtricity Storage Manager monitors the drives in the storage array and can notify you of an impending drive

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.2.4 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

E-Series Converting the Protocol of E2800 Host Ports (New Systems)

E-Series Converting the Protocol of E2800 Host Ports (New Systems) E-Series Converting the Protocol of E2800 Host Ports (New Systems) October 2016 215-11500_A0 doccomments@netapp.com Table of Contents 3 Contents Converting the Protocol of E2800 Host Ports (New Systems)...

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.3.2 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Replacing a Power Canister in E5760 or E2860 Shelves

Replacing a Power Canister in E5760 or E2860 Shelves E-Series Replacing a Power Canister in E5760 or E2860 Shelves Each 60-drive controller shelf or drive shelf includes two power canisters for power redundancy. If a power canister fails, you must replace

More information

Upgrading E5400 or EF540 Controllers to E5600 or EF560 Controllers when Using Fibre Channel and iscsi

Upgrading E5400 or EF540 Controllers to E5600 or EF560 Controllers when Using Fibre Channel and iscsi E-Series and EF-Series Upgrading E5400 or EF540 Controllers to E5600 or EF560 Controllers when Using Fibre Channel and iscsi You can upgrade an E-Series E5400 storage array or an EF-Series EF540 flash

More information

E-Series Controller Upgrade Guide

E-Series Controller Upgrade Guide E-Series Controller Upgrade Guide February 2018 215-11799_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Controller upgrade considerations... 5 Controller

More information

FlexArray Virtualization

FlexArray Virtualization FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

FlexArray Virtualization Implementation Guide for NetApp E-Series Storage

FlexArray Virtualization Implementation Guide for NetApp E-Series Storage ONTAP 9 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage June 2017 215-11151-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents Where to find information

More information

Replacing a Power-Fan Canister in E5700 or E2800 Shelves

Replacing a Power-Fan Canister in E5700 or E2800 Shelves E-Series Replacing a Power-Fan Canister in E5700 or E2800 Shelves Each 12-drive or 24-drive controller shelf or drive shelf includes two power supplies with integrated fans. These are referred to as power-fan

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Clustered Data ONTAP 8.3 Volume Disaster Recovery Preparation Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

Navigating VSC 6.1 for VMware vsphere

Navigating VSC 6.1 for VMware vsphere Navigating VSC 6.1 for VMware vsphere Virtual Storage Console for VMware vsphere works with the VMware vsphere Web Client and has dropped support for the VMware Desktop Client. This change means that VSC

More information

Volume Disaster Recovery Express Guide

Volume Disaster Recovery Express Guide ONTAP 9 Volume Disaster Recovery Express Guide December 2017 215-11188_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster

More information

Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards

Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards To access this product, go to the NetApp support site at mysupport.netapp.com. Planning the Host Interface

More information

OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View

OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View April 2017 215-12036_B0 doccomments@netapp.com Table of Contents 3 Contents Logging in to Cloud Manager... 4 Creating NFS volumes...

More information

Inventory Collect Tool 1.4

Inventory Collect Tool 1.4 Inventory Collect Tool 1.4 Host and Storage Information Collection Guide For Transition Assessment NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

SNMP Configuration Express Guide

SNMP Configuration Express Guide ONTAP 9 SNMP Configuration Express Guide December 2017 215-11190_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 SNMP configuration

More information

Replacing a drive in E5724 shelves

Replacing a drive in E5724 shelves E-Series Replacing a drive in E5724 shelves The Recovery Guru in SANtricity System Manager monitors the drives in the storage array and can notify you of an impending drive failure or an actual drive failure.

More information

Replacing a Battery in E2800 or E5700 Shelves

Replacing a Battery in E2800 or E5700 Shelves E-Series Replacing a Battery in E2800 or E5700 Shelves Each controller canister in an E5700 or E2800 storage array includes a battery that preserves cached data if the AC power fails. To protect your data,

More information

Replacing a Drive Drawer in a 60-Drive Tray

Replacing a Drive Drawer in a 60-Drive Tray E-Series Replacing a Drive Drawer in a 60-Drive Tray The steps to replace a failed drive drawer in an E-Series 60-drive tray depend on whether the volumes in the drawer are protected by Drawer Loss Protection.

More information

Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray

Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray To access this product, go to the NetApp Support Site at mysupport.netapp.com. Planning the Host Interface Card Upgrade Use

More information

Disaster Recovery for Enterprise Applications with ONTAP Cloud

Disaster Recovery for Enterprise Applications with ONTAP Cloud Technical Report Disaster Recovery for Enterprise Applications with ONTAP Cloud Step-by-Step Guide Shmulik Alfandari, NetApp September 2016 TR-4554i Abstract This document describes the required steps

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Updated for 8.3.1 Clustered Data ONTAP 8.3 Using All Flash FAS with Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

All other components in the system must be functioning properly; if not, you must contact technical support.

All other components in the system must be functioning properly; if not, you must contact technical support. 80xx systems For all operating environments Replacing a chassis To replace the chassis, you must remove the power supplies, fan modules, and controller module or modules and I/O expansion module, when

More information

Installing a Cisco Nexus 3132Q-V cluster switch and a passthrough panel in a NetApp cabinet

Installing a Cisco Nexus 3132Q-V cluster switch and a passthrough panel in a NetApp cabinet Installing a Cisco Nexus 332Q-V cluster switch and a passthrough panel in a NetApp cabinet You can install the Cisco Nexus 332Q-V switch and pass-through panel in a NetApp cabinet with the standard brackets

More information

SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter

SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter July 2017 215-12093_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding on whether to read this information... 4 Importing

More information

Replacing an E5700 or E2800 Controller (Duplex Configuration)

Replacing an E5700 or E2800 Controller (Duplex Configuration) E-Series Replacing an E5700 or E800 Controller (Duplex Configuration) Each controller canister contains a controller card, a battery, and, optionally, a host interface card (HIC). When you replace a controller

More information

NetApp Data ONTAP Edge on SoftLayer

NetApp Data ONTAP Edge on SoftLayer Technical Report NetApp Data ONTAP Edge on SoftLayer Express Setup Guide Jarod Rodriguez, NetApp April 2016 TR-4502 Abstract This document provides instructions on how to quickly install NetApp Data ONTAP

More information

All other components in the system must be functioning properly; if not, you must contact technical support.

All other components in the system must be functioning properly; if not, you must contact technical support. 62xx systems For all operating environments Replacing a chassis To replace the chassis, you must remove the controller module or modules and I/O expansion module, when present, from the old chassis, remove

More information

Replacing a Failed Controller Canister in the EF550 Flash Array

Replacing a Failed Controller Canister in the EF550 Flash Array Replacing a Failed Controller Canister in the EF550 Flash Array To access this product, go to the NetApp Support Site at support.netapp.com. Use this procedure to replace a controller canister in the EF550

More information

Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray

Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray To access this product, go to the NetApp support site at support.netapp.com. You can determine

More information

OnCommand Cloud Manager 3.0 Administration Guide

OnCommand Cloud Manager 3.0 Administration Guide OnCommand Cloud Manager 3.0 Administration Guide June 2016 215-11111_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Backing up Cloud Manager... 5 Removing

More information

Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray

Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray To access this product, go to the NetApp support site at mysupport.netapp.com. You can determine whether you have a failed controller

More information

Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray

Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might

More information

iscsi Configuration for Windows Express Guide

iscsi Configuration for Windows Express Guide ONTAP 9 iscsi Configuration for Windows Express Guide December 2017 215-11180_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage March 2017 215-09444_B0 doccomments@netapp.com Table of Contents 3 Contents Preparing to use Windows hosts with ONTAP storage...

More information

Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray

Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray To access this product, go to the NetApp Support Site at support.netapp.com. You can determine whether you have a failed controller

More information

Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray

Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might

More information

NDMP in Clustered Data ONTAP for Tape Backup Software Applications

NDMP in Clustered Data ONTAP for Tape Backup Software Applications Technical Report NDMP in Clustered Data ONTAP for Tape Backup Software Applications Subhash Athri, NetApp June 2015 TR-4376 TABLE OF CONTENTS 1 NDMP Backups... 3 1.1 Tape Backup Topologies in Clustered

More information

Replacing the chassis

Replacing the chassis FAS9000 and AFF A700 systems Replacing the chassis Before you begin All other components in the system must be functioning properly; if not, you must contact technical support. About this task You can

More information

Installing and Configuring for AIX

Installing and Configuring for AIX SANtricity System Manager 11.30 Installing and Configuring for AIX Express Guide August 2016 215-11221_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this Express Guide...

More information

Replacing the chassis

Replacing the chassis FAS8200 systems Replacing the chassis To replace the chassis, you must move the power supplies, fans, and controller modules from the impaired chassis to the new chassis, and swap out the impaired chassis

More information

Replacing the chassis

Replacing the chassis AFF A200 systems Replacing the chassis Before you begin All other components in the system must be functioning properly; if not, you must contact technical support. About this task You can use this procedure

More information

Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray

Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray NOTE Possible equipment damage Only a qualified service technician should perform this procedure,

More information

SMB/CIFS Configuration Express Guide

SMB/CIFS Configuration Express Guide ONTAP 9 SMB/CIFS Configuration Express Guide November 2017 215-11170_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 SMB/CIFS configuration

More information

Inventory Collect Tool 2.2

Inventory Collect Tool 2.2 Inventory Collect Tool 2.2 Host and Storage Information Collection Guide For Transition Assessment NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager

OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager April 2017 215-12037_B0 doccomments@netapp.com Table of Contents 3 Contents Updating Cloud Manager... 4 Enabling automatic updates...

More information

Upgrading a Host Interface Card in the E5560 Controller-Drive Tray

Upgrading a Host Interface Card in the E5560 Controller-Drive Tray Upgrading a Host Interface Card in the E5560 Controller-Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might result.

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Clustered Data ONTAP 8.3 FC Configuration for ESX Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

FC Configuration for Windows Express Guide

FC Configuration for Windows Express Guide ONTAP 9 FC Configuration for Windows Express Guide December 2017 215-11173_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration

More information

SolidFire and AltaVault

SolidFire and AltaVault Technical Report SolidFire and AltaVault Back Up SolidFire Storage to the Cloud by Using AltaVault Mike Braden, NetApp August 2016 TR-4542 Abstract Effectively using storage at scale is how organizations

More information

E-Series Cabling E-Series Hardware

E-Series Cabling E-Series Hardware E-Series Cabling E-Series Hardware September 2018 215-13049_A0 doccomments@netapp.com Table of Contents 3 Contents Overview and requirements... 4 Cabling your storage system... 5 Host cabling... 5 Cabling

More information

Replacing drives for SolidFire storage nodes

Replacing drives for SolidFire storage nodes NetApp Replacing drives for SolidFire storage nodes You can hot-swap a failed solid-state disk (SSD) drive with a replacement drive. Before you begin You have a replacement drive. You have an electrostatic

More information

Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray

Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray The controller canister in either a E5512 controller-drive tray or a E5524 controller-drive tray has cache

More information

Replacing Failed Memory in the E2760 Controller-Drive Tray

Replacing Failed Memory in the E2760 Controller-Drive Tray Replacing Failed Memory in the E2760 Controller-Drive Tray To access this product, go to the NetApp Support Site at support.netapp.com. The controller canister in an E2760 controller-drive tray has both

More information

FC Configuration for ESX Express Guide

FC Configuration for ESX Express Guide ONTAP 9 FC Configuration for ESX Express Guide March 2017 215-11179-C0 doccomments@netapp.com Updated for ONTAP 9.1 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration

More information

NFS Client Configuration for ESX Express Guide

NFS Client Configuration for ESX Express Guide ONTAP 9 NFS Client Configuration for ESX Express Guide December 2017 215-11183_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 NFS

More information

Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray

Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray To access this product, go to the NetApp Support Site at mysupport.netapp.com. Before you replace the power-fan canister

More information

Replacing a PCIe card

Replacing a PCIe card AFF A800 systems Replacing a PCIe card To replace a PCIe card, you must disconnect the cables from the cards, remove the SFP and QSFP modules from the cards before removing the riser, reinstall the riser,

More information

Replacing a PCIe card

Replacing a PCIe card AFF A700s systems Replacing a PCIe card To replace a PCIe card, you must disconnect the cables from the cards in the riser, remove the riser, replace the riser, and then recable the cards in that riser.

More information

All Flash FAS SAN-Optimized Configuration

All Flash FAS SAN-Optimized Configuration Technical Report All Flash FAS SAN-Optimized Configuration Michael Peppers, NetApp June 2016 TR-4480 Abstract This technical report provides details about the SAN-optimized configuration for NetApp All

More information

Cluster and SVM Peering Express Guide

Cluster and SVM Peering Express Guide ONTAP 9 Cluster and SVM Peering Express Guide December 2017 215-11182_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Prerequisites

More information

NFS Configuration Express Guide

NFS Configuration Express Guide ONTAP 9 NFS Configuration Express Guide December 2017 215-11172_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 NFS configuration workflow...

More information

Replacing a Failed Drive in the EF550 Flash Array

Replacing a Failed Drive in the EF550 Flash Array Replacing a Failed Drive in the EF550 Flash Array To access this product, go to the NetApp Support Site at support.netapp.com. You can determine whether you have a failed drive in two ways: The Recovery

More information

Adding, Upgrading, or Replacing Host Interface Cards in E2800 Controller Shelves

Adding, Upgrading, or Replacing Host Interface Cards in E2800 Controller Shelves E-Series Adding, Upgrading, or Replacing Host Interface Cards in E800 Controller Shelves You can add host interface cards (HICs) to E800 controller shelves that have only baseboard host ports. Adding HICs

More information

Replacing Cisco Nexus 3132Q-V cluster switches

Replacing Cisco Nexus 3132Q-V cluster switches Replacing Cisco Nexus 3132Q-V cluster switches You must be aware of certain configuration information, port connections and cabling requirements when you replace Cisco Nexus 3132Q-V cluster switches. The

More information

iscsi Configuration for ESX Express Guide

iscsi Configuration for ESX Express Guide ONTAP 9 iscsi Configuration for ESX Express Guide December 2017 215-11181_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi configuration

More information

Volume Move Express Guide

Volume Move Express Guide ONTAP 9 Volume Move Express Guide June 2018 215-11197_G0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume move workflow... 5 Planning the method and timing

More information

1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:

1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node: AFF A200 systems Replacing DIMMs You must replace a DIMM in the controller module when your system registers an increasing number of correctable error correction codes (ECC); failure to do so causes a

More information

Cluster Switch Setup Guide for Cisco Switches. October _A0_ur005

Cluster Switch Setup Guide for Cisco Switches. October _A0_ur005 Cluster Switch Setup Guide for Cisco Switches October 2017 215-06775_A0_ur005 doccomments@netapp.com Table of Contents 3 Contents Switches supported by ONTAP... 4 Setting up the switches... 5 Required

More information

NetApp SolidFire Element OS. Setup Guide. Version March _A0

NetApp SolidFire Element OS. Setup Guide. Version March _A0 NetApp SolidFire Element OS Setup Guide Version 10.2 March 2018 215-12911_A0 doccomments@netapp.com Table of Contents 3 Contents SolidFire system overview... 4 Configuring a storage node... 5 Configuring

More information

Replacing a Controller Battery in the ST2500 M2 Array Module

Replacing a Controller Battery in the ST2500 M2 Array Module Replacing a Controller Battery in the ST2500 M2 Array Module Version 10.77 May 2011 51348-00, Rev. A Replacing a Controller Battery in the ST2500 M2 Array Module May 2011 Revision History Version and Date

More information

Replacing the NVDIMM battery

Replacing the NVDIMM battery AFF A800 systems Replacing the NVDIMM battery To replace the NVDIMM battery, you must remove the controller module, remove the battery, replace the battery, and then reinstall the controller module. About

More information

Replacing a Cisco Nexus 5596 cluster switch

Replacing a Cisco Nexus 5596 cluster switch Replacing a Cisco Nexus 5596 cluster switch Replacing a defective Cisco Nexus 5596 cluster switch in a cluster network is a nondisruptive procedure (NDU). Before you begin The following conditions must

More information

Volume Disaster Recovery Preparation Express Guide

Volume Disaster Recovery Preparation Express Guide ONTAP 9 Volume Disaster Recovery Preparation Express Guide August 2018 215-11187_F0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster recovery

More information

Upgrade Express Guide

Upgrade Express Guide ONTAP 9 Upgrade Express Guide December 2017 215-11234_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Cluster software update workflow...

More information

E-Series Maintaining E2800 Hardware

E-Series Maintaining E2800 Hardware E-Series Maintaining E2800 Hardware September 2018 215-13051_A0 doccomments@netapp.com Table of Contents 3 Contents Batteries... 6 Overview and requirements... 6 Battery overview... 6 Requirements for

More information

This diagram shows the workflow of the DIMM replacement procedure for a FAS2600 system.

This diagram shows the workflow of the DIMM replacement procedure for a FAS2600 system. FAS2600 series Replacing DIMMs This diagram shows the workflow of the DIMM replacement procedure for a FAS2600 system. Video overview This video shows an overview of the DIMM replacement procedure for

More information

Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop

Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop Technical Report NetApp FAS and HBase Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop Ankita Dhawale and Karthikeyan Nagalingam, NetApp September 2016 TR-4541 Abstract This document introduces

More information

NetApp SANtricity Storage Replication Adapter 5.6 Best Practices Guide

NetApp SANtricity Storage Replication Adapter 5.6 Best Practices Guide NetApp SANtricity Storage Replication Adapter 5.6 Best Practices Guide September 2016 215-10052_C0 doccomments@netapp.com TABLE OF CONTENTS SRA DOWNLOAD... 2 INSTALLATION PROCEDURE... 2 PASSWORD PROTECTED

More information

Upgrading or Host Interface Card in the ST2500 M2 Array Module

Upgrading or Host Interface Card in the ST2500 M2 Array Module Upgrading or Host Interface Card in the ST2500 M2 Array Module Version 10.77 May 2011 51346-00, Rev. A Upgrading or Replacing a Host Interface Card in the ST2500 M2 Array Module May 2011 Revision History

More information

StorageGRID Webscale NAS Bridge Management API Guide

StorageGRID Webscale NAS Bridge Management API Guide StorageGRID Webscale NAS Bridge 2.0.3 Management API Guide January 2018 215-12414_B0 doccomments@netapp.com Table of Contents 3 Contents Understanding the NAS Bridge management API... 4 RESTful web services

More information

SolidFire CLI Tools Release Notes

SolidFire CLI Tools Release Notes NetApp SolidFire CLI Tools Release Notes Version 1.5 November 2017 215-12706_A0_ur001 doccomments@netapp.com Table of Contents 3 Contents About these release notes... 4 New in this release... 5 Known

More information

NetApp System Manager 1.1 Quick Start Guide

NetApp System Manager 1.1 Quick Start Guide NetApp System Manager 1.1 Quick Start Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 USA Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

HCI File Services Powered by ONTAP Select

HCI File Services Powered by ONTAP Select Technical Report HCI File Services Powered by ONTAP Select Quick Start Guide Aaron Patten, NetApp March 2018 TR-4669 Abstract NetApp ONTAP Select extends the NetApp HCI product, adding a rich set of file

More information

iscsi Configuration for ESXi using VSC Express Guide

iscsi Configuration for ESXi using VSC Express Guide ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

Optimizing SAP Lifecycle Management with NetApp Solutions for SAP HANA

Optimizing SAP Lifecycle Management with NetApp Solutions for SAP HANA Technical Report Optimizing SAP Lifecycle Management with NetApp Solutions for SAP HANA Nils Bauer, NetApp July 2015 TR-4439 Abstract This technical report describes the optimization of SAP lifecycle management

More information

NetApp E-Series Storage Systems Hardware Cabling Guide

NetApp E-Series Storage Systems Hardware Cabling Guide NetApp E-Series Storage Systems Hardware Cabling Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

Replacing the boot media

Replacing the boot media FAS8200 systems Replacing the boot media The boot media stores a primary and secondary set of system (boot image) files that the system uses when it boots. Depending on your network configuration, you

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide April 2018 215-11792_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

OnCommand Unified Manager Reporting for Clustered Data ONTAP

OnCommand Unified Manager Reporting for Clustered Data ONTAP Technical Report OnCommand Unified Manager Reporting for Clustered Data ONTAP Dhiman Chakraborty, NetApp October 2015 TR-4122i Abstract This technical report (TR) introduces the reporting features that

More information

7-Mode Transition Tool 3.3 Installation and Setup Guide

7-Mode Transition Tool 3.3 Installation and Setup Guide 7-Mode Transition Tool 3.3 Installation and Setup Guide September 2017 215-12329-A0 doccomments@netapp.com Table of Contents 3 Contents Transition to ONTAP by using the 7-Mode Transition Tool... 4 Comparison

More information

Cluster Switch Setup Guide for Cisco Switches. May _A0_UR006

Cluster Switch Setup Guide for Cisco Switches. May _A0_UR006 Cluster Switch Setup Guide for Cisco Switches May 2018 215-06775_A0_UR006 doccomments@netapp.com Table of Contents 3 Contents Switches supported by ONTAP... 4 Setting up the switches... 5 Required cluster

More information

NetApp Storage Replication Adapter for E- Series Installation and User Guide

NetApp Storage Replication Adapter for E- Series Installation and User Guide NetApp Storage Replication Adapter for E- Series Installation and User Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-08653_A0 495 East Java Drive Fax: +1 (408) 822-4501 Release date:

More information

Installing and Configuring for Windows

Installing and Configuring for Windows SANtricity Storage Manager 11.40 Installing and Configuring for Windows Express Guide September 2017 215-11886_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this Express

More information

AltaVault Cloud Integrated Storage Installation and Service Guide for Virtual Appliances

AltaVault Cloud Integrated Storage Installation and Service Guide for Virtual Appliances AltaVault Cloud Integrated Storage 4.4.1 Installation and Service Guide for Virtual Appliances April 2018 215-130007_B0 doccomments@netapp.com Table of Contents 3 Contents System requirements and supported

More information

Upgrading Memory in the 6580/6780 Controller CRU

Upgrading Memory in the 6580/6780 Controller CRU Upgrading Memory in the 6580/6780 Controller CRU May 2011 51360-00, Rev. A ST2501 M2 Drive Module Initial Setup Guide May 2011 Revision History Version and Date 51360-00, Rev. A, May 2011 Initial release

More information

SANtricity Storage Manager Express Guide

SANtricity Storage Manager Express Guide SANtricity Storage Manager 11.25 Express Guide For VMware and Fibre Channel NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information