1 O UT IN O UT IN O UT IN (-) NO C 12 (+) 12 NO C GND IN A B A B A B T E RM I NAL I NT ERFACE O= Clear operations counter L xx=day(s) between battery load test C xx=day(s) between battery check test T=Battery load test CAUTIO N HOT RESISTOR!! S =Battery check test t akes 15 minutes?=d isply all values and selections E =exit terminal mode xx=value betw een 0 and 99 A l terminal inputs must be t erminated w ith the EN TER key S T AT US I ND I CA TOR S Bli n k in g Ch e c k Batter y LED, L oad or Check test in progress C ontinuosly iluminated Check Battery LE D, Battery Failure Bli n k in g L i ne A cti v e LE D, A C is present and unit functional C ontinuously of Line Active L ED, AC Line Failure K n if e S wit ch Cl o s e LE D, I luminated when sw itch closed T erminal S etting TTY N-1 F low C ontrol N one? E NTER, TO S TART C OM. OPTIONAL OPERATIONAL COUNTER LOCATION Document PC Dimensional Data - Output Unit, Enclosure, and Cable Connector Ø 1 1/8 COMMUNICATION CABLE Ø 1/2 9 Ø 1 1/8 3 1/8 CABINET END 2 1/2 SENSOR END 11 3/4 OUTPUT UNIT 11 3/4 x 2 1/2 x 9 2 5/ /4 TYPICAL MOUNTING 23 7/8 Ø 5/8 (X5) 3 32 BATTERY TESTER 28 TYP MNTG HEATER & FAN ASSY OUTPUT UNIT 2 12V 33AH BATTERIES Ø13/16 (X3) Sample Catalog Numbers The following sample catalog numbers (with quantities) are representative of typical complete systems. A complete system includes a Sensor Unit(s), an Output Unit, an Enclosure and Power Source, and Cable(s) (01) CSVS , (01) CVO , , (01) E1-125-S, (01) CAB One 550 BIL, 1200 amp combination current and voltage Sensor Unit, one Output Unit with 0-1A current output signal (O1 = 1A, O2 = null, O3 = null) and VAC voltage output signal (O1 = 1.44 VA, O2 = null, O3 = null), one standard enclosure utilizing customer supplied 125 VAC, and one 25 ft cable (03) CSVS , (01) CVO , , (01) E2-024-L, (03) CAB Three 350 BIL, 600 amp combination current and voltage Sensor Units, one Output Unit with 0-1A current output signals (O1 = 1A, O2 = 1A, O3 = 1A) and VAC voltage output signals (O1 = 1.44 VA, O2 = 1.44 VA, O3 = 1.44 VA), one large enclosure with SEECO supplied 24 VDC power source, and three 45 ft cables 6
2 Document PC Dimensional Data kv,, Type CSVS Sensor units 230 kv and up are provided complete with corona suppression rings, which are not depicted here. For additional details consult the factory. Dimensions in Inches (Unless Otherwise Specified) kv BIL A 54 1/2 63 1/2 71 1/2 89 1/ / / /2 B
3 Document PC Dimensional Data kv,, Type CSVS Dimensions in Inches (Unless Otherwise Specified) kv BIL A /2 22 1/2 26 1/2 30 1/2 38 1/2 B 7 1/
4 Document PC Catalog Numbers and Ratings To properly configure a complete sensor application, you must specify the catalog numbers for a sensor unit, an output unit, an enclosure and power source, and a communication cable. Consult the factory if assistance is needed to correctly specify the system components. Enclosure and Power Source Enclosure Size Std Large Power Source Catalog Value Supp. By Number 024 VDC Customer E1-024-S 048 VDC Customer E1-048-S 125 VDC Customer E1-125-S 120 VAC Customer E1-120-S 024 VDC Customer E1-024-L 024 VDC SEECO E2-024-L 048 VDC Customer E1-048-L 125 VDC Customer E1-125-L 120 VAC Customer E1-120-L Solar SEECO E4-024-L Enclosure catalog E1-125-S Power Source - The Output Unit will operate with customer supplied 24, 48, and 125 VDC or 120 VAC. An optional SEECO supplied 24 VDC power source complete with batteries, battery charger, and battery testing mechanism can be provided, which requires customer supplied 120 VAC. A solar power source can also be supplied for geographically remote applications. Enclosure - The Output Unit is provided complete with an enclosure. The standard enclosure is provided for most typical applications and is sized to accommodate the output device, terminal blocks for output signal wiring connections, up to three circular, MS connectors and power source inputs. A larger enclosure is available and is sized to accommodate the above material plus the optional SEECO supplied 24 VDC or solar power source, or other customer equipment. Communication Cable Catalog Number Base Length CAB -XXXX Note: To complete the Communication Cable catalog number, add the required cable length to the base catalog number. Add leading zeroes where necessary to create a four digit length value, i.e. a 175 foot linear length would be specified as CAB Communication from the Sensor Unit to the Output Unit is digital not analog, providing a maximum cable length of up to 4,000 feet. The cable length can be specified in 10 foot increments. One cable is required per Sensor Unit. The cable has a UV protected black PVC jacket, which is sunlight resistant, impervious to moisture and vapor penetration and is suitable for installation in both wet and dry locations. Each end of the cable is pre-terminated with a circular, MS connector for quick and easy connection to both the Sensor and Output Unit devices. Cable is suitable for direct burial. Cable catalog CAB
5 Document PC Catalog Numbers and Ratings To properly configure a complete sensor application, you must specify the catalog numbers for a sensor unit, an output unit, an enclosure and power source, and a communication cable. Consult the factory if assistance is needed to corrrectly specify the system components. Sensor Unit Voltage Catalog Number Nom BIL Wght, kv kv 600 Amp 1200 Amp 2000 Amp Lbs CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS CSVS Specify the catalog number that corresponds to your BIL and continuous current requirements. Output Unit Output Signal Format Catalog Number Current Outputs Voltage Outputs Current Voltage Base O1 O2 O3 O1 O2 O3 0-.5A/0-1A 0-67/0-115 CVO XX -XX -XX -ZZ -ZZ -ZZ 0-10 VAC CVO XX -XX -XX -WW -WW -WW 0-10 VAC 0-67/0-115 CVO YY -YY -YY -ZZ -ZZ -ZZ 0-10 VAC CVO YY -YY -YY -WW -WW -WW Note: To complete the Output Unit catalog number, add the required value to each of the six output signal fields of the base catalog number. If no output signal is required for the second or third current and voltage fields use 00 to represent null value. For current outputs XX use values.5 (0-.5A) or 01 (0-1A); for current outputs YY use 01 (1.44A). For voltage outputs WW use 01 (1.44 VA); for voltage outputs ZZ use 01 (1.44 VA), 15 (15 VA) or 25 (25 VA). Output Signal Formats - Current output signals are available with a standard format of 0-1 amp and optional formats of 0-.5 amp or 0-10 VAC (1.44 VA). Standard burden range is 0 to 2 ohms. Voltage output signals are available with standard formats of or 0-67 and an optional 0-10 VAC. Standard VA is 1.44 but optional 15 and 25 VA are available for the and 0-67 outputs. The 1.44 and 15 VA can be provided on all three outputs but the 25 VA can be provided for up to two outputs only. Other formats may be supported. Please contact the factory if your device requirements are other than the standard formats listed here. Inputs/Outputs - The Output Unit accepts up to three current inputs and three voltage inputs and provides up to six analog outputs. This allows a single Output Unit to support up to three Sensor Units of the same or different ratings. Alternately, the input signal from a single Sensor Unit can be used to provide up to three output signals for three separate load devices (meters, relays, rtu s, etc.). 2
6 Document PC Combination Current and Voltage Sensor Type: CSVS (current and voltage) Mounting Orientation: Any direction Continuous Current: 600, 1200, 2000 Amp Voltage: kv (line to line) BIL Rating: kv Accuracy: +/-.15% (current); +/- 5% (voltage) Description A light weight monitoring insulator (data collection device) capable of reproducing in phase proportional sinusoidal current and voltage waves for communication to customer devices (meters, relays, rtu s, etc.). Application Replaces conventional oil-filled CT/PT devices and optical sensors in applications such as voltage and current monitoring, relaying, fault detection (with direction), and autosectionalizing or SCADA operation of switches SEECO 69 kv 1200 amp current and voltage sensor, catalog CSVS (wght 44 lbs) Ordering Information Standard Equipment Type CSVS current and voltage sensors consist of four major components; a Sensor Unit, Communication Cable, an Output Unit and an Enclosure. The Sensor Unit monitors both phase current and voltage and generates digital current and voltage output signals. The Sensor Unit consists of a silicon polymer insulator, current sensing coil, voltage sensing rod, line and base unit electronic cards and fiber optic cabling and potting. The Communication Cable transmits the Sensor Unit output signal to the Output Unit. The Communication Cable is provided in length as specified by the customer. Each end of the cable is terminated with a circular, MS connector. One cable is required per sensor unit. The Output Unit receives the digital current and voltage outputs from the Sensor Unit(s) and converts them to analog values for interface with the customer s devices. One Output Unit can support up to three different Sensor Units or provide up to three output signals for one sensor. Features & Benefits Small footprint, compact size Less than 10% of the weight of oil-filled devices Can be mounted in any orientation; provides flexibility in areas with limited clearances No CT saturation or PT Ferro Resonance No catastrophic failure; cannot overheat or explode Environmentally friendly, no oil or SF6 used as a dielectric; no special handling or disposal procedures No galvanic connection between potential and ground Generates safe, low voltage and low current outputs To Be Specified on Order A checklist is available to assist you in organizing and completing the information required; the following minimum information must be specified: Sensor Unit Catalog Number and quantity BIL Rating (kv) and Continuous Current Rating Mounting structure w/ details and dimensions Output Unit Catalog Number Required output (current): 0-.5A, 0-1A, or 0-10 VAC Required output (voltage): 0-67, or 0-10 VAC Required VA of each signal output: 1.44, 15 or 25 Communication Cable Catalog Number and quantity Power source for Output Unit: 24, 48, 125, or 120 Enclosure Catalog Number Optional equipment or non-standard features An Enclosure is provided for each Output Unit and includes terminal blocks for digital and analog output signal wiring connections, power inputs and circular, MS connectors. 1
Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording
Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 100 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationDIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG
CATALOG INTRODUCTION The temperature monitor MASTERTEMP was developed to monitor oil and winding temperatures in transformers and reactors immersed in oil. It features also the activation of cooling fans
More informationEffective May 2018 Supersedes October 2017
Technical Data TD280028EN Supersedes October 2017 COOPER POWER SERIES NOVA NX-T Recloser, Form 6 NX-T, and Form 6LS NX-TRecloser Control and Accessories Ordering Guide Eaton provides reliable, economical
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationElastimold Molded Vacuum Recloser - MVR
Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical
More informationSmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch
installation instructions SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch 2013 Hubbell Incorporated hpsliterature@hubbbell.com hubbbellpowersystems.com The equipment covered by these installation
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationLineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2
Bulletin DB50C18 LineScope Smart Power Monitor US Patent Nos. 9664710, 9746498, and 9810720B2 14000 Rt. 993, Trafford, PA 15085 p 724-864-4177 f 724-864-9040 e sales@cleavelandprice.com The LineScope Overview
More informationENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS
ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationS&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches
S&C M Series Switch Operator Sophisticated Microprocessor Control of Overhead Distribution Switches S&C s M Series Switch Operator is a fully integrated, microprocessor-based operator that lets you automate
More informationLED55WPG Programmable LED Driver
Dimmable Constant Current Rev 8-9-7 Electrical Specifications Input Voltage Range: Frequency: Power Factor: Inrush Current: Input Current (Max): -77 Vac Nom. (8-35 V Min/Max) 5/6 Hz Nom. (47-63 Hz Min/Max)
More information955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS
Series ebrik INSTALLATION MANUAL LINEAR DISPLACEMENT TRANSDUCERS ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS Introduction The is an accurate programmable, auto-tuning, noncontact, linear
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationMW/MVAR Transducer Specifications
GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output
More informationFamily of Water Cut Analyzers
Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water
More informationZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER
ZENSOL AUTOMATION INC. COMPUTERIZED TEST EQUIPMENT ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER CBA-32P Micro CBA MANUAL 1W E OPERATOR S GUIDE Version 1.70 January 2001 www.zensol.com Man-1we.doc Rév 5
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationDIN Molded Cable Assemblies
DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting
More informationEP-ELVCTL Elevator Control (NION-16C48M)
EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding
More informationEM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter
EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar
More informationNT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230
P/N 0-027289 (Rev. A 04/4) NT PRESSURE TRANSDUCER MODELS 400, 420, 430, 4230 User Guide Table of Contents Safety Alert Symbol... 2 Introduction... 3 Installation... 3 Mechanical Installation... 3 Electrical
More informationMultifunction Transducer MT440
Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationAPS SCALE SERIES DIMENSIONS
APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section
More informationS025W-056C W Programmable LED Drivers
Rev 12-14-17 Electrical Specifications Maximum Power: 25W Typical Efficiency: 88% Input Voltage Range: 1-277 Vac Nom. (108-305 V Min/Max) Frequency: 50/ Hz Nom. (47-63 Hz Min/Max) Power Factor: 0.90 @
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationXT-9100 Technical Bulletin
System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationMeasure & Control Temperature & CO2 levels with analog & digital I/O
MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature
More informationThis Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.
This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationEARTH-FAULT AND SHORT-CIRCUIT INDICATOR TYPE EKL8001 / EKL8002 surface mounted
EARTH-FAULT AND SHORT-CIRCUIT INDICATOR TYPE EKL8001 / EKL8002 surface mounted General description The earth-fault and short-circuit indicators type EKL8001 and type EKL8002 can be used in radial networks
More informationDC3IOB Revision User Guide Updated 3/29/10. Overview
Revision 080910 User Guide Updated 3/29/10 Overview The is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The integrated PLC
More informationProduct Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance
Product Overview The PowerFlex 520-Series AC drive delivers an innovative design that is remarkably versatile and can accommodate systems ranging from standalone machines to simple system integration.
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationBERMAD Irrigation. BIC Wire RTU
BIC 2500 2-Wire RTU System guide Versions : 2007 Contents 1. System Overview 3 1.1. Technical SpecificationS 3 1.1. System ComponentS 4 2. Installation 5 2.1 Cable Test 5 2.2. Ground RodS 6 2.3 Addressing
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationVisoVac padmount fault interrupter
Network Protector Catalog Data CA024003EN New Issue VisoVac padmount fault interrupter General The medium voltage padmount vacuum fault interrupter from Eaton delivers economical, reliable and flexible
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationH3G-380 Production Description
H3G-380 Production Description Designed for UPS battery strings of 15 to 48 batteries each of VRLA and Ni-Cd battery 1 Applications For strings of 15 to 48 batteries each Data Center IT Data Room 2 Product
More informationProgrammable Relay ZEN V2 Units
Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationSite Preparation CHAPTER
CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationCOIL CHARACTERISTICS (Vdc) SERIES H,HD,HP,HT,HTD,HPT GENERAL CHARACTERISTICS. Date of issue: 06/ Page 2 of 5. B Vdc
ENGINEERING DATA SHEET CONTACTOR AMP BalancedForce Design Hermetically sealed Designed to the performance standards of MILPRF6 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 8 and 5 Vac, 400 Hz,
More informationS Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II
Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88
More informationAnalog Output Isolators
TURCK Interface Technology Analog output isolators are for use with conventional 4/20 ma or HART smart "IS" devices are available in 1 and 2 channel versions. These devices are designed to provide a convenient
More informationFX-2 Control Board ASY-360-XXX Setup and Configuration Guide
FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...
More informationMC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA
MC-1 MINI CAMERA OPERATION MANUAL JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA 02718 USA (508) 822-7330; (800) 822-4744; FAX (508) 880-8949 Email: info@jwfishers.com WEB: www.jwfishers.com SPECIFICATIONS
More informationPGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document
More informationS Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME
Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form
More informationDRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System
Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)
More informationABB Digital medium-voltage switchgear
NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital
More informationPower and Expansion Selection
CJ1 SYSTEM POWER AND EXPANSION Power and Expansion Selection This section provides tools to calculate the CJ1 system current total needed to select the power supply. When the number of modules or power
More informationLAST UPDATED
AST UPDATED 372018 1 Tronxy X5S Bed Upgrades Three Upgrades eeded Insulation of Heat Bed Install offboard power to drive the Increase Voltage driving the from 12Vdc to 20 Vdc BED Insulation I Installed
More informationIRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.
IRM-5000P insulation resistance meter Vanguard Instruments Company, Inc. www.vanguard-instruments.com IRM-5000P insulation resistance meter The IRM-5000P is a microprocessor-based, high-voltage, insulation-test
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationFully-Automated Multi-Function Electrical Safety Compliance Analyzers
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIA Series Fully-Automated Multi-Function Electrical Safety Compliance Analyzers U.S. Patent Nos. (6,054,865, 6,011,398,
More informationETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features
Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...
More informationHoneywell Model 700/800 Signal Processor and Viewing Head
Honeywell Model 700/800 Signal Processor and Viewing Head USER MANUAL Model 700ACSP Universal 85-265 VAC powered, plus 24VDC backup. Model 700DCSP 22-26VDC powered, plus 24VDC backup. The two Model 700
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationBA/BS4S Temperature Sensor Installation & Operating Instructions
Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationLineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation
LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationData Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121
Data Isolation Cards ADSL High Voltage Isolation Card Single Line Voice Isolation Card With CID, CW & MWI Floated 48VDC Input P30120 Floated 130VDC or 120VAC Input P30121 Description & Installation Printed
More informationDEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S
Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,
More informationProximity Sensor Lineup
Sensor Lineup sensors allow non-contact detection of objects. They are used in many industries, including manufacturing, robotics, semiconductor, etc. Inductive sensors detect metallic objects while capacitive
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Active communication with patented MX-AOPC UA Server and Active OPC Server 2 switched Ethernet ports for daisy-chain topologies Easy
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationS&C 6801M Automatic Switch Operator
S&C 6801M Automatic Switch Operator for Overhead Distribution Switches and Disconnects Simple, Economical Switch Automation S&C s 6801M Automatic Switch Operators make it easy to automate new or existing
More informationMINER-S Station Controller
MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,
More informationDS5000-IBFS. 5kA rms - 8kA DC Fluxgate current transducer. Features. Description. Application. Precision Innovation /
5kA rms - 8kA DC Fluxgate current transducer Features DC 8000A AC 5000A rms Maximum gain error DC to 1kHz - 0.1% Transducer core optimized for high level of immunity against external magnetic fields Operating
More informationMXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.
MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process
More informationTURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet
Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the
More informationRTK4 Logic Controller User Manual For RTK4L Revision Revised
RTK4 Logic Controller User Manual For RTK4L Revision 120326 Revised 6-20-12 RTK4 Features Application: PLC and Third Party Drive Interface Number of Axis Drive Interfaces: 5 Axis DAC Resolution: 16 bits
More informationINTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL
INTRINSICALLY SAFE DUPLEXER INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision:
More informationSpecifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.
Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.4 kv and 25 kv) Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationAPPLICATION GUIDE. Interface Modules IM Series.
Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to
More informationIEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton
K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration
More informationDielectric Withstand and Ground Bond Testers
Dielectric Withstand and Ground Bond Testers For Safety Agency Production Line Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The
More informationCentroid ACORN CNC controller Specification and Use Guide Updated 8/3/17. Overview
Centroid ACORN CNC controller Specification and Use Guide Updated 8//7 Overview ACORN is technically a CNC control breakout board for the BeagleBone Green or BeagleBone Black embedded computer the Beagle
More informationBus Bar Protection Relay B-PRO 4000
Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation
More informationINTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx
INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box
More informationiologik R1200 Series User s Manual
User s Manual Edition 3.2, November 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used
More informationRemote Telemetry Unit
Remote Telemetry Unit The NCC Series Remote Telemetry Unit provides cellular alarming, reporting, and operations logging. The product allows you to remotely monitor events on your mobile device and/or
More informationSensus T866 MicroRTU. Remote Input/Output Control. Applications. Reporting Methods DATA SHEET
Sensus T866 MicroRTU Remote Input/Output Control The Sensus Distribution Automation (DA) T866 MicroRTU is a cost effective solution for monitoring, controlling, and operating remote equipment such as switches,
More informationMANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31
MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31 PPS PART NO. 133550 DRAWING NO. 133550-10 THIS MANUAL ASSIGNED TO THE S/N: THE INFORMATION CONTAINED IN THIS MANUAL IS PROPRIETARY TO PACIFIC POWER SOURCE,
More informationLKAT2 OEM. Bi-Directional High Current Measurement with Rectifier Protection. Key Features. Description. Application
Key Features True bi-directional performance. Ideal for difficult magnetic applications. No position or bus analysis needed. Standard alarm relay provides reverse or over-current protection. Measurement
More informationTerminal Junction System (MIL-T and Commercial)
Introduction Product Facts The TJS connections are inherently more reliable than conventional threaded and solder terminations. The user s wiring is crimped to gold plated pin contacts, conforming the
More informationDC3IOB Revision User Guide Updated 7/12/12. Overview
DC3IOB Revision 080910 User Guide Updated 7/12/12 Overview The DC3IOB is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The