This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

Size: px
Start display at page:

Download "This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits."

Transcription

1 This Datasheet for the IC660BB00 Block elay Output ormally Closed 6 Circuits Provides the wiring diagrams and installation guidelines for this GE Series 90-0 module. For further information, please contact Qualitrol Technical Support at support@qualitrol.com

2 6-Circuit elay Output Block June 00 GFK-008E Description elay Output blocks provide 6 output circuits in four independent groups of four relay-type outputs each. The block power may be either 5V or 0V AC. There are two types of elay Output blocks: ormally-closed elay Output Block (IC66*BB00), ormally-closed contacts ormally-open elay Output Block (IC66*BB0), ormally-open contacts elay blocks are compatible with a wide range of low-power control and indicating devices such as relays, contactors, and lamps. Output devices may operate in the range of 5V to 50V AC or 5V to 0V DC, and switch up to 60 Watts or 5 VA. Features elay Output ormally Open ( 5/0 ) 50/60 z Each group of four outputs on a elay Block can be powered by a separate AC or DC source. Group to group isolation is 500 volts. Block features include: Output powerup defaults Output old Last State or default CPU edundancy type Bus Switching Module control Using this Datasheet This datasheet summarizes information about block installation, configuration, and diagnostics. Your primary reference should be the Discrete and Analog Blocks User s Manual. It includes detailed instructions for block installation and configuration. For additional information about systems and communications, including bus specifications, refer to the I/O System and Communications Manual. Specifications Catalog umber Output Block, ormally- IC66*BB00 Closed elays Electronics IC66*EB00 Terminal IC66*TB00 Output Block, ormally- IC66*BB0 Open elays Electronics IC66*EB0 Terminal IC66*TB0 Block Specifications Size (height x width x depth) 8.8 (.cm) x. (8.8cm) x.9 (9.9cm) Weight lbs. (.8 kg) s (I/O Block) Unit OK, I/O Enabled s (each circuit) Individual relay coil state Environmental Specifications Operating temperature 0 C to +60 C (+ to +0 F) Storage temperature -0 to +00 C (-0 to + F) umidity 5% to 95% (non-condensing) Vibration 5-0 z 0. (5.08mm) displacement, 0-00 z at G Block Power Specifications Frequency 7-6 z Operating voltage (5) 9 to ; (0) 85 to 65 Power requirement 87mA at 5 Power supply dropout time cycle Isolation All outputs to chassis ground 500 Between output groups 500 Power terminals to chassis ground 700 VDC Power terminals to outputs 500 Comms terminals to power terminals 700 VDC Comms terminals to outputs 500 eat Dissipation 0. watts max. with 6 outputs on Output Specifications Maximum Output current Amps per circuit Maximum switching power 60 Watts or 5 VA Maximum inrush current Amps per circuit Output OFF leakage current 0. ma Maximum switching frequency 0 cycles/minute (inductive loads) Output turn-on delay (maximum) 5ms Output voltage range 5V to 50V AC or 5V to 0V DC Minimum recommended load 0mA elay Specifications elay Type Fixed coil moving armature Initial Contact esistance 00 milliohms, maximum Typical Life: Operating Maximum Current for Load* Type Typical Life Voltage esistive Lamp Solenoid (operations) A , A 0.A 00, A 0.A 0.A 00,000 0 VDC 0.A ,000 0 VDC 0.6A ,000 0VDC.0A ,000 0VDC -- 0.A 0.A 00,000 VDC -- 0.A 0.5A 00,000 Effect of Load on Operating Life Operating Current in Load Type Typical Life Voltage esistive Lamp Solenoid (operations) 50 0.A ,500, A -- --,000,000 0VDC.0A -- --,000,000 VDC.0A -- --,000,000 * Lamp loads are defined as a X0 inrush with a power factor (PF) of.00; when turned OFF, they represent a PF of.00. Solenoids are defined as a X0 inrush with a PF of 0.65; when turned OFF, they represent a PF of 0.5. efer to GFK-0867 for product standards and general specifications.

3 6-Circuit elay Output Block June 00 GFK-008E Compatibility These blocks are compatible with a and-held Monitor identified by catalog number IC66*M50 only. For an IC697 series PLC, the CPU and programming software must be version.0 or later. The Bus Controller must be IC697BEM7C or later. For an IC600 series PLC, the CPU must be rev. 05 or later. For an IC600 Plus series PLC, rev. 0 or later is required. The programming software must be rel..0 or later. For an IC550 series PLC, the CPU must be rev..0 or later. The programming software must be rel..0 or later. Installation Instructions Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system. Block Mounting Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least inches of space between blocks. Mount the block by drilling two screw or bolt holes for 8- hardware. Position the block so that the notches in the upper and lower flanges line up with the mounting holes. Mount the block using 8- screws. Use star washers to provide ground integrity. Grounding The block s mounting screws must not be used as the only means of grounding the block. Connect the green ground screw on the block to a reliable ground system using a short wire lead, minimum size AWG # (avg.mm in cross-section). Warning If mounting screws do not make good ground connection and the ground screw is not connected to a reliable ground, the block is not grounded. Electrical shock hazard exists. Death or personal injury may result. Block Wiring Do not overtorque the terminal screws. ecommended torque for all terminals is 6 in/lb (.678 /M). Serial Bus Wiring Using one of the cable types recommended in the System and Communications User's Manual connect the serial bus to terminals - as shown. (If the block will be used as a controller, do not attach the serial bus to terminals -. See "Using a elay Block as a Controller" instead). Terminals to are for the serial bus. These terminals accept one AWG # wire (avg.mm cross-section) or two AWG # wires (each avg.mm in cross-section). The minimum recommended wire size is AWG # (avg.6mm in cross-section). Terminals - can also accommodate spade or ring terminals up to 0.7 inch (6.85mm) wide with a minimum opening for a #6 screw, and up to 0.0 inch (5.mm) depth from the screw center to the back barrier. Be sure unshielded wire ends are not longer than inches (5 cm). If the block is at either end of the bus, connect a terminating resistor of the appropriate type (see the System and Communications User s Manual for details) across its Serial and Serial terminals. Terminating esistor Serial Serial Shield In Shield Out Start of Bus End of Bus Terminating esistor Serial Serial Shield In Shield Out Using a elay Block as a Controller A elay block can be used to control a Bus Switching Module. There are two different versions available. It is important to match the to the type of voltage that will power the block s outputs. If the voltage will be /8 VDC, version IC66*0 is required. If the voltage will be 5 or 5 VDC, IC66*0 is needed instead. Install the at the block s serial bus terminals, as described in the Bus Switching Module datasheet. Connect the bus cable to the. Connect the wires to the block as explained below. Field Wiring Terminals 5 to are for field devices. They take a single wire up to AWG # (avg.mm in cross-section). Minimum recommended size is AWG #0 (avg.5mm in cross-section). Power for AC loads may come from the block AC power supply or other AC source(s). Power for DC loads may come from one or more DC sources. Each group may use a separate AC or DC source. OTE: Make no connections to C terminals * Voltage per Isolated Group AC: 5 to 50 SEIAL or SEIAL SIELD I SIELD OUT J C C C 9 0 C 5 6 DC 5 to 0 VDC 5 set up when shipped from factory J 5 Block Power Options *5 * VDC J O 0 Example 5 Output Connections Example VDC Output Connection

4 6-Circuit elay Output Block June 00 GFK-008E Block Power elay Output blocks require a 5 or 0 power source. Voltage selection is made by jumpers on the Terminal. When shipped from the factory, the power selection jumpers are set for 5 operation. For 0 volt AC power, change the jumpers as shown. Correct jumper placement is important; incorrect jumper placement may result in damage to the block. Connect the power source to the and terminals (5 and 8). For applications where Class Division conditions must be met for Factory Mutual, install an external 50 volt /8 amp slow-blow fuse in series with the ot AC power connector as shown below. 50V, /8 Amp slow-blow fuse AC Power Source With the external fuse indicated, this block meets FM Class Divi sion requirements. Block and Points Powered by 5 If the block and points are powered by 5, connect one wire of version IC66*0 to point and connect the other wire to. Jumpering terminal J to as shown above right allows the points to operate on the same 5 source that powers the block. Block Powered by, Points Powered by 5 or 5VDC If the block is powered by 0 and the points are powered by either a 5 source or a 5 VDC source, use version 0. Connect one wire of the to point. For a 5 VDC source, connect the other wire to DC-. For a 5 source, connect the other wire to the neutral side of the power supply. DC- DC- for 5VDC source or neutral for 5 source 0 External Fuses and Snubbers J C DC+ for 5VDC source or for 5 source elay blocks have no internal fuses. Following normal practices, external fuses of Amps or less can be installed in series to protect loads. External snubbers are not necessary for correct operation of the block. owever, the use of snubbers is recommended. Snubbers will reduce switching transient pulses and lengthen the contact life of the relays. Use a diode connected in parallel with a DC inductive load or an -C network across the contacts. (-) (+) 5 Jumper J C emoving an Electronics The block s Electronics can be replaced with a compatible model without removing field wiring or reconfiguring the block. etaining Screws (Qty. ) Electronics Block Powered by 0, Points Powered by -8VDC If the block is powered by 0 and the points are powered by a -8 VDC source, connect one wire of version IC66*0 to point and the other to DC- (-8VDC). Terminal To Power Supply 0 DC+ To Power Supply J C Connector Pins. Unscrew the retaining screws at the top and bottom of the block.. Using a Block Puller (IC660BLM507), engage the tabs in the first vent slots. Move the tool to the center of the block and squeeze the handle.. Pull the Electronics upward. Warning If power is applied to the field terminals, power is also exposed on the connector pins at the base of the Terminal, and electrical shock hazard exists. Do not touch the connector pins! Death or injury may result.

5 6-Circuit elay Output Block June 00 GFK-008E Inserting an Electronics. Align the Electronics in the guides and push down firmly. Caution Do not exert excessive force; it may damage the block.. If unusual resistance is met, remove the Electronics. If power is applied to the block, DO OT TOUC TE COECTO PIS! Inspect the Terminal, connector receptacle, and connector edge board (on the Electronics ). Be sure the keying matches. emove any obstacles and reinsert the Electronics. Pay close attention to the alignment of the guide pins.. Secure the Electronics with the screws on the top and bottom of the Terminal. Block Operation All 6 relay-type outputs are either normally-open or normallyclosed, depending on the block version. Outputs are grouped into four groups of four relays. Each group of four shares a common input terminal. Each circuit has its own that shows the commanded state of the coil. A logical received from the CPU causes the block to energize the corresponding relay coil, and 0 causes the coil to be deenergized. This has opposite effects on these two blocks. When the coil of a normally-open relay is energized, the relay is energized and the relay contact closes. When the coil of a normally-closed relay is energized, the relay contact opens. The elay Output blocks provide an EEPOM Failure diagnostic only. There are no diagnostics associated with the individual circuits. Circuit S show the commanded state of each coil. Common Field Connections ote: MOV elay Terminal Voltage Electronics Control from Micro processor elay ormally-open version shown. ormally-closed is the same, except for relay type. s The block's Unit OK and I/O Enabled s show its operating status: Unit OK I/O Meaning Enabled O O Block functioning, CPU communicating O OFF Block functioning o CPU communications for bus scans O Blinking Block functioning, Circuit forced Blinking O Circuit fault, CPU communicating Blinking OFF Circuit fault o CPU communications for bus scans Alternate Blinking Circuit fault, Circuit forced Synchronous Blinking OFF Don t Care o CPU communications - block number conflict o block power, or block faulty Individual circuit S show the commanded state of each coil. Configuration First, the block must be configured with a and-held Monitor to: Enter its Device umber (serial bus address). Enter its eference umber (required only for IC600 and IC550 series PLCs only). ote: If a block is configured offline, it must be properly grounded and have a 75 Ohm resistor installed across its Serial and Serial terminals. See the Discrete and Analog I/O Blocks User s Manual for instructions. The rest of the features can be configured either using a and-held Monitor, or by sending a Write Configuration datagram to the block from the host. Feature Circuit or Block Factory Setting Selections Device umber Block null 0 to (a number must be selected) eference Address Block none Depends on host CPU type Baud ate Block 5.6 std 5.6 std, 5.6 ext, 76.8, 8. Kbd old Last State Circuit no yes, no Output Def. State Circuit coil off coil on, off Present Block no yes, no Controller Block no yes, no Outputs Default Time edundancy Mode Blockl bus scans.5, 0 seconds Block none none, duplex, hot standby Duplex Default Block off on, off Configuration Block disabled enabled, disabled Protection

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits. This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits. This Datasheet for the IC0BBD02 Block /12/24Vdc Sink I/O 32 Circuits http://www.qualitrol.com/shop/p-14433-ic0bbd02.aspx Provides the wiring diagrams and installation guidelines for this GE Series 0-30

More information

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs. This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines

More information

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines

More information

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits. This Datasheet for the IC660BBD101 Block 115Vac I/O Low Leakage 8 Circuits http://www.cimtecautomation.com/parts/p-14434-ic660bbd101.aspx Provides the wiring diagrams and installation guidelines for this

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.qualitrol.com/shop/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0 module.

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0

More information

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels. This Datasheet for the IC660BBA101 Block 115Vac/125Vdc RTD Input 6 Channels http://www.qualitrol.com/shop/p-14423-ic660bba101.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit. This Datasheet for the IC0BBS0 Block Vac/Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit. http://www.cimtecautomation.com/parts/p-0-ic0bbs0.aspx Provides the wiring diagrams and installation

More information

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels. This Datasheet for the IC660BBA103 Block 115Vac/125Vdc Thermocouple Input 6 Channels http://www.qualitrol.com/shop/p-14424-ic660bba103.aspx Provides the wiring diagrams and installation guidelines for

More information

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible This Datasheet for the IC0BBD0 Block Vdc Source I/O Circuits, / Wire Sensor Compatible http://www.cimtecautomation.com/parts/p-0-ic0bbd0.aspx Provides the wiring diagrams and installation guidelines for

More information

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT. This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT http://www.qualitrol.com/shop/p-14508-ic670gbi002.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940 May 2015 PACSystems* RX3i and Series 90-30 IC693MDL940 / IC694MDL940 Output Module, Relay, NO, 2 Amp, 16 Point The Series 90*-30 and PACSystems * MDL940 2 Amp Relay Output module provides 16 normally-open

More information

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped. This Datasheet for the IC670MDL70 /VDC 0.A Output Pos. Logic 6 Pt. Grouped http://www.cimtecautomation.com/parts/p--ic670mdl70.aspx Provides the wiring diagrams and installation guidelines for this GE

More information

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect This Datasheet for the IC0MDL0 VDC A Output Pos. Logic Pt. Electronic Short Circuit Protect http://www.qualitrol.com/shop/p-0-ic0mdl0.aspx Provides the wiring diagrams and installation guidelines for this

More information

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point January 2010 PACSystems RX3i and Series 90-30 IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TB IC694MDL916 Q1 Q2 Q3 Q4 Q5 Q6 Q7

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner. This Datasheet for the IC697BM733 Series 90-70 Genius. http://www.cimtecautomation.com/parts/p-14756-ic697bem733.aspx Provides the wiring diagrams and installation guidelines for this G Series 90-30 module.

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

PACSystems RX7i IC698CHS009/119

PACSystems RX7i IC698CHS009/119 January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i

More information

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

More information

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual 506 and 507 Relay Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped. This Datasheet for the IC670MDL64 48VDC Pos/Neg Logic Pt. Grouped http://www.qualitrol.com/shop/p-46-ic670mdl64.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

Analog Voltage Combination Module

Analog Voltage Combination Module Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased

More information

PACSystems* RX3i IC695PSA140

PACSystems* RX3i IC695PSA140 August 2012 PACSystems* RX3i IC695PSA140 120/240VAC or 125VDC, 40 Watts The PACSystems * RX3i IC695PSA140 is a multi-purpose 40-Watt supply that operates from an input voltage source in the range of 85

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Shown with terminal block Supports diagnostic point fault contacts in the logic program GFK-2482F PACSystems* RX3i Isolated Analog Input Modules, IC695ALG106-EA, IC695ALG112-EA Product Description Isolated Analog Voltage/Current Input module IC695ALG106 provides 6 isolated input channels.

More information

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual C E G E L E C Alspa CE80 20 N80 Bus Interface Unit User s Manual First issue: 04 1995 This edition: 05 2000 Alspa CE80 20 N80 Bus Interface Unit User s Manual Page 1 RevisionsPrefaceReader s commentscontentsfigurestables

More information

IC693 PLC IC693ACC350, IC693ACC340/341

IC693 PLC IC693ACC350, IC693ACC340/341 March 29, 2001 IC693 PLC IC693ACC350, IC693ACC340/341 Redundant Power Supply System he IC693 Redundant Power Supply System consists of a Baseplate and an Adapter, described below. Redundant Power Supply

More information

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series This Datasheet for the for the Series 90-70. http://www.cimtecautomation.com/parts/p-14754-ic697bem721.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PSA040 August 2012 PACSystems* RX3i IC695PSA040 Power Supply, 120/240VAC or 125VDC, 40 Watts The PACSystems * RX3i power supply IC695PSA040 is a 40-Watt supply that operates from an input voltage source in the

More information

PACSystems RX3i IC695PSA140

PACSystems RX3i IC695PSA140 GFK2399A October 2005 PACSystems RX3i IC695PSA140 120/240VAC or 125VC, 40 Watts IC695PSA140 is a multipurpose 40Watt supply that operates from an input voltage source in the range of 85 to 264 VAC or 100

More information

ICS Regent. AC Guarded Digital Output Module 110 VAC (T3464) PD-6021

ICS Regent. AC Guarded Digital Output Module 110 VAC (T3464) PD-6021 ICS Regent PD-6021 AC Guarded Digital Output Module 110 VAC (T3464) Issue 1, March, 06 AC Guarded digital output modules provide guarded switching of user-supplied 110 AC voltages to a maximum of sixteen

More information

This Datasheet for the IC697BEM731. Series Genius I/O Bus Controller.

This Datasheet for the IC697BEM731. Series Genius I/O Bus Controller. This Datasheet for the IC697EM731 Series 90-70 Genius I/O us Controller. http://www.cimtecautomation.com/parts/p-14755-ic697bem731.aspx Provides the wiring diagrams and installation guidelines for this

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module March 2002 Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module Features 32 Points - Four isolated groups of eight points each 0.5 amp capacity per point High inrush capacity

More information

Discrete Output Modules IC697MDL740

Discrete Output Modules IC697MDL740 55 1 IC697MDL740 (IC697MDL740) datasheet Features 16 Points - Four isolated groups of 4 points each 2 amp capacity per point High inrush capacity (10x rated current) Functions The 24/48 Volt DC 2 Amp Output

More information

Discrete Output Modules IC697MDL750

Discrete Output Modules IC697MDL750 54 IC697MDL750 (IC697MDL750) datasheet Features 32 Points - Four isolated groups of 8 points each a44709 0.5 amp capacity per point High inrush capacity (20x rated current) Functions The 24/48 Volt DC

More information

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check Product Description Revision Letter: BA Firmware version: 1.10 Firmware upgrades: DeviceNet Certification: Product Name: None Certificate available upon request. DeviceNet Network Control Module (NCM)

More information

GE Fanuc IC694BEM331 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694bem331 Rx3i PacSystem RX3i Genius Bus Controller (supports I/O and Datagrams). IC694B IC694BE IC694BEM 919-535-3180

More information

User safety and equipment protection guidelines

User safety and equipment protection guidelines Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped. This Datasheet for the IC670MDL240 120VAC 16 Pt. Input Grouped http://www.qualitrol.com/shop/p-14511-ic670mdl240.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control

More information

Analog Input, 16-Bit Thermocouple Module

Analog Input, 16-Bit Thermocouple Module Analog Input, 16-Bit Module Product Description The Analog Input Module is an intelligent module that accepts seven independent thermocouple or millivolt inputs. The module receives power from the backplane

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer EXPRESS SETUP PanelMate 1700 Series PanelMate Power Pro Cutler-Hammer Installation Unpacking Carefully remove all equipment from the packing cartons and inspect all parts for damage in shipment. Check

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

INSTALLATION MANUAL SLI 50 INVERTER

INSTALLATION MANUAL SLI 50 INVERTER INSTALLATION MANUAL SLI 50 INVERTER www.unipowerco.com Manual No. SLI-50-48-3 2016 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR AUGUST 14, 2001 REVISION 1 Publication: SE-135-M Document: S95-C135-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.

More information

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped. This Datasheet for the IC670MDL640 24VDC Pos/Neg Logic Input 6 Pt. Grouped http://www.cimtecautomation.com/parts/p-4-ic670mdl640.aspx Provides the wiring diagrams and installation guidelines for this GE

More information

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms. DL06 PLC I/O DL06 I/O SPECIFICATIONS D0-06DD2-D Wiring diagram and specifications DC Power Supply DC Input DC Output D0-06DD2-D Voltage Range Number of Input Pts. Number of Commons Input Voltage

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

170 ADO VDC - 32 Pt. Discrete Output Module Base

170 ADO VDC - 32 Pt. Discrete Output Module Base 31001697 9/2010 170 ADO 350 00 24 VDC - 32 Pt. Discrete Output Module Base 27 Overview This chapter describes the 170 ADO 350 00 TSX Momentum I/O base. What's in this Chapter? This chapter contains the

More information

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input. This Datasheet for the IC670MDL2 120VAC 8 Pt. Isolated Input http://www.qualitrol.com/shop/p-14510-ic670mdl2.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module.

More information

MT8050iE series. Installation Instruction (1) (2)

MT8050iE series. Installation Instruction (1) (2) MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup

More information

Installation Instructions

Installation Instructions Installation Instructions (1771-ODD Series B) Use this document as a guide when installing the catalog number 1771-ODD series B output module. The ac isolated output module is shipped in static-shielded

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V. This Datasheet for the IC670ALG310 Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V http://www.qualitrol.com/shop/p-14493-ic670alg310.aspx Provides the wiring diagrams and installation guidelines for

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10 G540 User Manual Date Modified: March 5, 2012 Page 1 of 10 DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 50 VDC Motor Current 0 3.5 A Power Dissipation 1 13 W Short

More information

Relay Contact Output Modules

Relay Contact Output Modules Relay contact output modules offer dry circuits, that is, circuits without leakage current. Leakage currents are present on solid-state outputs; these currents are capable of energizing highly sensitive

More information

Technical Manual SMART TRAC PS Card

Technical Manual SMART TRAC PS Card Technical Manual SMART TRAC PS Card Contents Important Safety and Warranty Information 1 Warnings, Cautions and Notes...1 General Safety Precautions - Warnings...2 Important Warranty Information...2 Smart

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

IC693PWR331 High Capacity Power Supply, 24 VDC Input

IC693PWR331 High Capacity Power Supply, 24 VDC Input IC693PWR331 High Capacity Power Supply, 24 VDC Input The Series 90-30 DC input High Capacity power supply (IC693PWR33) is a 30 watt wide range supply designed for 24 VDC nominal inputs. For applications

More information

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112 SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V Product Information SIMATIC S7-300 Digital Output Module SM 322; DO 16 UC24/48 V X 2 as of Version 3 4 New Digital Output Module Available The S7-300 Digital Output Module SM 322; DO 16 UC24/48 V has been

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

ADDJOG User Guide 7/30/10. Overview

ADDJOG User Guide 7/30/10. Overview ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.

More information

PFC Mini TM Power Factor Corrected AC-DC Switchers

PFC Mini TM Power Factor Corrected AC-DC Switchers 21 PFC Mini TM Power Factor Corrected AC-DC Switchers Overview Technical Description The PFC Mini is an extremely low profile switching power supply that combines the advantages of power factor correction,

More information

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual 50 and 50 Digital I/O Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE G540 MANUAL MULTIAXIS STEP MOTOR DRIVE PRODUCT DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 50 VDC Motor Current 0 3.5 A Power Dissipation 1 13 W Short Circuit Trip

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION

More information

VersaMax* Analog Input, 16-Bit Thermocouple Module

VersaMax* Analog Input, 16-Bit Thermocouple Module VersaMax* Analog Input, 16-Bit Module Product Description The Analog Input Module is an intelligent module that accepts seven independent thermocouple or millivolt inputs. The module receives power from

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date: Class: Date: MECH1500Quiz1ReviewVersion2 True/False Indicate whether the statement is true or false. 1. The number and type of I/Os cannot be changed in a fixed PLC. 2. In a PLC system, there is a physical

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

Analog Input Installation Manual

Analog Input Installation Manual Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems

More information

1395 Node Adapter Board Troubleshooting

1395 Node Adapter Board Troubleshooting 1395 Node Adapter Board Troubleshooting Specifications Electrical: Board power provided by Drive (+5V) Discrete Input 24V DC or 115V AC, jumper selectable Environmental: Ambient Operating Temperature Storage

More information

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc.

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc. This Datasheet for the IC660BSM120 BUS Switching Module 115Vac/125Vdc http://www.cimtecautomation.com/parts/p-14451-ic660bsm120.aspx Provides the wiring diagrams and installation guidelines for this GE

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01 Mitsubishi Electric Automation Instruction Manual FR-A5AC-01 AC Input Interface Option Unit NOTE: CAUTION: WARNING: NOTES, CAUTIONS AND WARNINGS Notes are used to provide additional detail about a procedure.

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs MAN0959-01 PAGE 1 Mix102 module ` SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs 1 SPECIFICATIONS Digital DC Inputs Digital Relay Outputs Inputs per Module 12 Outputs

More information

16-Channel Digital Output Module 120Vac/dc

16-Channel Digital Output Module 120Vac/dc Triguard SC300E MDO16FNS 16-Channel Digital Output Module 120Vac/dc (MDO16FNS) Issue 4 October 2005 INTRODUCTION PURPOSE The 120Vac/dc Digital Output Module MDO16FNS provides the output control interface

More information

24 Input/8 Output AC Block I/O Module

24 Input/8 Output AC Block I/O Module 4 Input/8 Output AC Module Cat. No. 79-4A8 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to

More information