Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
|
|
- Lindsay Bishop
- 5 years ago
- Views:
Transcription
1 Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded adapter and DIN/ANSI flanges for tank mounting are also available. The electrical connection is either via ready-made cable or connector. Features Continuous linear measuring signal Direct reading of medium level High-resolution reed contact measuring chain Simple installation Compatible with the digital multifunction device GEMÜ 1276 for optical indication and signal evaluation, e.g. limit s witch points Variable mounting positions Advantages The device is used for monitoring liquid levels of inert and corrosive media For applications with open, closed and pressurized tanks Materials: Choice of PVC-U, PP, PVDF, stainless steel Weight-saving construction Dimensions 25 Total length B Installation length A Ø 55 SW55 Ø 75 C D Table of dimensions see page 4
2 Technical data Working medium Corrosive and inert liquid media which have no negative impact on the physical and chemical properties of the medium wetted parts Mounting notes Protection class Mounting position Weight PP (1 m length) PVDF (1 m length) PVC-U (1 m length) Stainless steel (1 m length) Materials Medium wetted parts Choice of PVC-U, PP, PVDF, stainless steel Cable connection Cable gland PVDF / packing rubber PVC Connection housing Housing ABS Cover PMMA Protective cap for screws PVDF Adapter ABS or st. st Connector PA 6 Plug screw VQSt Profile packing Nitrile rubber Fastening screw Mounting flange DIN PVC-U, PP, PVDF, st. st ANSI PVC-U, PP, PVDF, st. st G 2 PVC-U, PP, PVDF, st. st Operating conditions IP 65 in connection range vertical 0.3 kg 0.5 kg 0.4 kg 1.8 kg Permissible ambient temperature C * Permissible medium temperature Tube/float material PVC-U C * Tube/float material PP C * Tube/float material PVDF C * Tube/float material stainl. steel C * Permissible operating pressure PVC-U, PP, PVDF, stainless steel max. 6 bar * *) see table Pressure / temperature correlation for plastic Electrical connections Cable connection PG 13.5 with LIYY 3x0.38 mm² cable Connection housing 1 piece 3-pole socket DIN EN Form A, Recommended cable diameter 8-10 mm Auxiliary power Chain of resistors 2.4 kω per 230 mm measuring length Uv 40 V DC Max. perm. signal current Is 100 ma 2-wire current loop 4-20 ma U min = 11 V A x series resistance U max = 40 V Output signal Resistance depending on level* 2.4 kω per 230 mm measuring length 0V Usignal Uv Current loop Series resistance Resolution Linearity 4-20 ma, 2-wire system see diagram 2.3 / 4.6 mm linear * Evaluation as changeable resistance or voltage divider Series resistance - Diagram 2 Supply voltage max. perm. voltage 40 V Series resistance max Ω Pressure / temperature correlation for plastic Temperature in C (plastic body) -10 ± Valve body material PVC-U PP PVDF
3 Order data Mounting flange G 2 Clamp sleeve G 2, height adjustable (only connection code K1-K3) DIN flange (not connection code 20) ANSI flange (not connection code 1 and20) Connection Cable gland, wire length 1 m Cable gland, wire length 3 m Cable gland, wire length 6 m Connection housing, 1x connector DIN EN Form A SH DF AF K1 K2 K3 SB Materials PVC-U, hard, grey 1 PP, polypropylene 5 PVDF 20 Stainless steel Output signal Chain of resistors 01 2-wire 4-20 ma (only connection code SB) 02 Installation lengths 470 mm mm mm mm mm mm mm mm 2100 Materials see dimension table page 5 Measuring lengths 230 mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 2.3 mm A mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B mm Resolution 4.6 mm B2050 For coordination installation length - measuring length see table on page 4. Order data K A0930 Type Mounting flange () Connection () K3 Material () 05 Output signal () 01 Installation length () 1000 Measuring length () A0930 3
4 Dimensions Total length B Installation length A Ø 55 SW55 Ø 75 C D Float Dimension table Material Installation length A Total length B Measuring start C Measuring length D Stainless steel PVC-U, PP, PVDF (PVC-U) (PP) (PVDF)
5 Dimensions of connection housing ,5 38,5 SW55 Dimensions of mounting flange DIN ( DF), ANSI ( DA) Material ød øk ød2 b M DIN metal (Stainless steel ) ANSI metal (Stainless steel ) DIN plastic (PVC-U. PP. PVDF) ANSI plastic (PP)
6 Connection diagram - 2-wire transducer Connection diagram - Chain of resistors U Analog measuring unit or analog input / PLC Power source 2 brown (br) U mA 1 white (wh) I Figure: Terminal of connector U 2 white (wh) Sensor supply 10 V DC 1 green (gn) Colour: Wire colour of cable connection 3 brown (br) Signal output All rights including copyright and industrial property rights are expressly reserved. Application example: Multifunction display GEMÜ 1276 GEMÜ 1276 is a digital display unit for electrical standard signals used in measurement and control engineering applications as a panel mountable unit. The varied features enable a large number of applications. The GEMÜ measured value indicators can be connected with this type of device, starting from simple display applications to combined switch point evaluations and other serial signal interfaces. For further level transmitter, accessories and other products please see our Product Range catalogue and Price List. Contact GEMÜ. Subject to alteration 03/ Should there be any doubts or misunderstandings, the German version of this data sheet is the authoritative document! VALVES, MEASUREMENT AND CONTROL SYSTEMS GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Str. 6-8 D Ingelfingen-Criesbach Tel. +49(0) 7940/123-0 Telefax +49(0) 7940/ info@gemue.de
Limit switches Instrument sensors
Limit switches Instrument sensors Construction GEMÜ 12 Limit switch with built-in bistable reed contact (change-over) GEMÜ 1251-1257 Limit switches with built-in bistable reed contact (NO) GEMÜ 1270-1271
More information410, 417, 423. Butterfly valve, Plastic
Butterfly valve, Plastic Construction GEMÜ 410, 417 and 423 are centric butterfly valves in nominal sizes N 15-100. The valve body is made of PVC-U, the butterfly disc is made of PVF or PP. The available
More informationElectrical Position Indicator
Distributed by: Tel: 90.77.9000 Toll Free:.800.8.78 www.tricanada.com Electrical Position Indicator with microswitches Construction The GEMÜ 0 electrical position indicator has one or two mechanical microswitches.
More informationBall valve Metal. Sectional view. * see information on working medium on page PED/97/23/EC Category III Module H TA-LUFT
all valve Metal Construction GEMÜ is a 2/2-way stainless steel ball valve with top flange EN ISO 5211 in sizes DN 15 to 100. It has a low maintenance electric actuator with a powerful DC motor. The reduction
More informationGEMÜ 4232 Travel sensor for linear actuators
Travel sensor for linear actuators Features ATEX version available as an option Easy fitting to GEMÜ linear actuators Compact, stable housing Durable Can be retrofitted to GEMÜ valves or third-party actuators
More informationMotorized quarter turn actuator
Motorized quarter turn actuator Construction The GEMÜ 98 motorized quarter turn actuator is a compact design. The motor and gear are combined as one unit in a plastic housing. The quarter turn actuator
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationMagnetically Inductive Flowmeter
Magnetically Inductive Flowmeter Construction The GEMÜ mflow flowmeter operates according to the magnetically inductive measurement principle. It is suitable for electrically conductive media and enables
More information711, 728, 751. Ball Valve, Stainless steel Multi-port
Ball Valve, Stainless steel Multi-port Construction GEMÜ 711, 728 and 751 are 2/2-way stainless steel ball valves with top flange EN ISO 5211 in sizes 1/4 to 2 (DN 8 to DN 50). The top flange enables both
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationLevel sensor for monitoring the level of liquid media
Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150
More informationGEMÜ 723 Motorized ball valve
Motorized ball valve Features High flow rates Low weight Choice of various body materials and connection types Available as shut off or control valve / and /-way versions available The / and/or /-way ball
More informationRSK. Wafer Type Check Valve. Construction. Features. Advantages
Wafer Type Check Valve Construction The GEMÜ wafer type check valve is available in plastic or metal and the body, disc and seal can be chosen from various materials. The valve is clamped between two flanges
More informationLS series. Electrical Position Indicators for Quarter Turn Actuators
0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,
More informationGEMÜ 1235 Electrical position indicator
Electrical position indicator Features Communication and programming interface IO-Link Adjustable switch point tolerances Speed-AP function for fast mounting and initialisation High visibility position
More informationGEMÜ 9468 Motorized quarter turn actuator
Motorized quarter turn actuator Features Increased torque in the end positions with consistent motor load/rotational speed through threaded spindle kinematics (closing curve matched to valves) Low weight
More informationNew! CleanStar SonicLine High Purity PFA Ultrasonic Flowmeters. Extended low flow measuring range ⅜" unit: l/min.
CleanStar SonicLine High Purity PFA Ultrasonic Flowmeters Product overview and technical data New! Extended low flow measuring range ⅜" unit: 0.03-6 l/min. VALVES, MEASUREMENT AN CONTROL SYSTEMS Synergy
More informationFloat switch For industrial applications Model RLS-1000
Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic
More informationLevel sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H
Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement
More informationLevel switch NS 10/NS 25..-AM
Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationTHERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA
Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.
LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationselection of special materials is available to handle almost any fluid.
For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications
More informationFloat Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65
Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated
More informationLevel sensor with reed measuring chain Model FLR, for the process industry
Level measurement Level sensor with reed measuring chain Model FLR, for the process industry WIKA data sheet LM 20.02 for further approvals see page 3 Applications Level measurement for almost all liquid
More informationFlexible temperature transmitter and sensor
/ processing unit without display senso a mperature senso TT/TC series TT/TC ser Flexible temperature transmitter and sensor The of the TT/TC series detect temperature with a Pt100 4-wire probe. Available
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationMPreC - Pressure Relief Device Order specification sheet
- Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter
More informationFloat Switches with Permanent Magnet For Horizontal Installation Model HIF
Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical
More informationLinear Position Transducer HLT 1000-R2
7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More informationMagnetic float switch For vertical installation Model FLS
Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others
More informationLevel and temperature switch Nivotemp NT-M, NT-MD
Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible
More informationTemperature Switches
ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationDistance and Position Sensors
Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description
More informationM E A S U R I N G A N D
PRODUCT OVERVIEW M E A S U R I N G A N D CONTROL TECHNOLOGY Jacob GmbH - Measurement and control technology division Our Company We are a southern Germany family company, based in Kernen-Rommelshausen.
More informationLevel- and temperature sensor Nivotemp NT M-XP
Level- and temperature sensor Nivotemp NT M-XP Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored continuously. Here, modern factory automation requires
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationPRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.
MESSKO MPreC PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS. MESSKO MPreC -Series LARGE MESSKO PRESSURE RELIEF DEVICE (LMPRD) Operating pressure Project/Reference: Gasket material MPreC Typ 4 psi; 0.28
More informationContinuous level measuring system NB 3000 Selection list
Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationULTRASONIC LEVEL METERS ULM 53L
Preliminary data ULTRASONIC LEVEL METERS ULM 53L For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, etc. Customer
More informationDatasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *
09005318 DB_EN_DE44_LCD Rev. ST4-C 07/17 *09005318* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated
More informationElectronic Level Switch ENS 3000
Electronic Level Switch ENS 3000 Description: The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analogue output signal is available
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationScrew-in resistance thermometers with terminal head Form B
Data Sheet 90.2002 Page 1/7 s with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal head Form B, BUZ, BUZH, BBK
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationDS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.
Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable
More informationbidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental
and draw-wire sensors Spot-on and trailblazing technology measure rotation speed, sense, position, angle and length. For this purpose, they convert mechanical motion in electrical signals. There are incremental
More informationHydrostatic filling level sensor HFB C4 / R / MD
Hydrostatic filling level sensor HFB C4 / R / MD Pressure measuring range 0-0.5 bar Voltage supply 18 30 V DC Features Filling level detection through measuring the hydrostatic medium pressure by means
More informationLevel- and temperature sensor Nivotemp NT 67-XP
Level- and temperature sensor Nivotemp NT 67-XP Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored continuously. Here, modern factory automation requires
More informationBVS UR E Ordering code: BVS001H
BVS UR-3-101-E Ordering code: BVS001H Vision sensor BVS-E Universal PNP (2x) 1) Teach reference image, 2) Power, 3) Output 1 active, 4) Output 2 active, 5) Connection with PC, 6) Sharpness Characteristic
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive
More informationLevel and temperature switch Nivotemp NT-M, NT-MD
Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible
More informationCapacitive Sensors. Capacitive sensors for object detection
sensors for object detection Balluff capacitive sensors BCS are used for object and level detection. They measure all materials even non-conductive ones such as liquids, granules and powders in direct
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationTO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED SOCKETS IN THERMOSET TING MATERIAL
Page 1 TO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED S IN THERMOSET TING MATERIAL ADVANCE GRP marks another leap forward in SCAME technological research. ADVANCE GRP is the most
More informationCAPACITIVE SENSORS KAS
CAPACITIVE SENSORS KAS SerieS 95 Sensors for industrial automation in the Agriculture Industry Feed Industry Filling Level Control Backlog Jam Indication Full / Empty Indication Registration No.: 1327-01
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic
More informationTemperature sensors TTM series. Miniature transmitters
Temperature senso a mperature senso Temperature sensors TTM series TTM serie Miniature transmitters The TTM miniature sensors detect temperature with a 4-wire Pt1000 probe. Available are compact devices
More informationReed sensor For bypass level indicators Model BLR
Level measurement Reed sensor For bypass level indicators Model BLR WIKA data sheet LM 10.04 for further approvals see page 3 Applications Sensor for the continuous level measurement of liquids in bypass
More informationPosition Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX
Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle
More informationTemperature measurement TER8 Front-flush and low-invasive resistance thermometers
Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationTemperature Measurement SITRANS TS300
Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø
More informationDM28 - Economical Digital Process and Strain Gauge Panel Meters
DM28 - Economical Digital Process and Strain Gauge Panel Meters TRANSDUCERS Easily scaled in any engineering units from -19999 to 99999 Large 18mm (.71 ) high red or green display Front panel MIN, MAX
More informationPosition Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX
Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle
More informationCATALOGUE CAPACITIVE SENSORS KXS
CATALOGUE CAPACITIVE SENSORS KXS 2 For all transactions the newest version of "General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI" shall apply, with the supplementary
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationMinimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)
The air bubble detector is used to detect air or gas bubbles in plastic tubes filled with liquid and is intended to prevent air infusions. However, it can also be used as a wet/dry sensor. The sensor has
More informationDPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet
DPA+ LCD Differential Pressure Transmitter 703420 Datasheet Subject to technical alteration Issue date: 07.03.2018 A002 Application Differential pressure and volume flow transducer for monitoring differential
More informationInsertion RTD temperature probe
Data sheet 902350 Page 1/6 For temperatures between -50 and +260 C Steam-tight and pressure-resistant High mechanical strength For use in the food industry Available with multiple measuring points Due
More informationIndustrial Hydraulics FAQs
Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationLinear Position Transducer HLT 1000-R2
Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and