RMS Product Presentation

Size: px
Start display at page:

Download "RMS Product Presentation"

Transcription

1 RMS Product Presentation THE RELAY SPECIALISTS relay monitoring systems pty ltd

2 Relay Monitoring Systems Pty Ltd 6 Anzed Court - Melbourne - Australia

3 Manufacturing in Australia

4 Company History RPL Established Take Over 1970 RMS Take Over 1991 Product references with major power utilities in Australia Exports to UK, South Africa, Malaysia, Korea, Middle East, India, Thailand, Hong Kong, Pakistan, Indonesia + Marketing agreement with Reyrolle Protection & Mors Smitt

5 International Quality Accreditation AS/NZS ISO9001:2008

6 Product Range Overview

7 Test Blocks and Plugs RMS 4M300 4M300 Test Block 14 way with or without DC isolation 2M28-S case Front of panel testing for protection circuits Front of panel testing for metering circuits RMS 4M320 Test Plug with 4mm safety sockets Insertion handles

8 Test Plugs RMS 2RMLB 4M400 Test Block Compatible with Areva MMLB Compatible with Reyrolle 2RMLB Front of panel testing for protection circuits Front of panel testing for metering circuits

9 Circuit Breaker Control 1X50 CB Trip & Close Module Large size push buttons High visibility CB status LED s Suitable for 24, 32, 48, 110/125 & 240/250Vdc Optional CB spring charge status LED Optional locking cover Optional arc suppression circuitry Optional lamp test button & output contact Optional integrated control circuit steering diodes Optional custom engraving 4U rack or flush mounting 2M28-S case Provide independent breaker control Use with Reyrolle Argus-M

10 Arc Fault Protection 1S20 Arc Fault Monitor 2 Zone & 3 Sensors Air insulated metal clad switchgear Panel mount or DIN rail mount versions Low cost, can be used on per panel basis 1S30 Trip BUS CB(s) 1S30 50/51 1S30 1S20

11 HEALTH Y ZONE 1 TRIP Cus tom text ZONE 2 Cus tom text ZONE 3 Cus tom text ZONE 4 Cus tom text RESET /TEST FA IL TRIP FA IL TRIP FA IL TRIP FA IL Arc Fault Protection 1S25 Arc Fault Monitor 4 Zone & 8 Sensors 1S25 COMMON TRIP ALARM OUTPUTS

12 Arc Fault Protection 1S26 Arc Fault Monitor with Current Check 4 Zone & 8 Sensors

13 Alarm Annunciator 1A54 Alarm Panel 4, 8 & 16 point versions & up to 6 contacts per point Repeat output contacts (latching or self reset) Acknowledge & Reset Non volatile memory Universal binary input voltage Configuration code / switches 2M28-S case 4M56-S case Transformer alarms Station alarms Annunciators

14 Busbar Protection Relay RMS 2V73 High Impedance Differential (87B) Voltage operated 2M28-S case Equivalent to Areva MFAC Bus zone differential Machine differential Restricted earth fault See 2V75 for metrosil & resistors

15 Busbar Protection Relay RMS 2C73 High Impedance Differential (87B) Current operated 2M28-S case Equivalent to Areva MCAG Bus zone differential Machine differential Restricted earth fault See 2V75 for metrosil & resistors

16 High Impedance Differential Relay RMS 2C75-S High Impedance Differential Protection (87) Current Operated Fast Operate Speed (< 25msec) CT Supervision (50) CT Shorting Output CT Supervision Differential Block Logic USB programming port Modbus communication protocol 4M56-S case Medium and Low Voltage Bus Protection Stator Winding Differential Protection See 2V75 for metrosil & resistors

17 Metrosil Modules RMS 2V75 Metrosil & Resistor module 1 pole or 3 pole 3 inch or 6 inch metrosils 100W or 200W resistors Flush, rack or back of panel mount High impedance differential schemes Metrosil and resistors can be supplied loose

18 CT Supervision & Shorting Relay RMS 2V68 CT buswire supervision 3s fixed supervision delay 3 N/O latched contacts for supervision alarm 3 N/O latched contacts for buswire shorting Hand reset flag 4M28 case High impedance differential schemes

19 High Impedance Differential Schemes RMS 1M123 Electromechanical design 2V73 or 2C73 3x high impedance relays 2V75 metrosil & resistor module 2HSM trip relay 4M800K1 4U high 19 rack frame Bus zone differential Machine differential

20 Voltage Regulation Relay RMS 2V164-S umatrix digital platform USB programming port Fine & Coarse voltage bandwidths Undervoltage blocking Overvoltage alarm Overcurrent blocking Line drop compensation Tap position indication (TPI) when using 2V200 Optional Modbus communication protocol Optional analog outputs ma OLTC control

21 Parallel Control System RMS 1M122A Master follower parallel control scheme 2V164 - voltage regulation relay 2V165 - parallel control relay 1X200 - control module 2V200 - tap position transducer 4M800K1-19 sub rack OLTC parallel control for up to 4 transformers

22 TPI Transducer & Indicator RMS 2V200 Tap position transducer Resistor chain or BCD inputs 0 to 5kHz output For use with 2V164 or 4D200 RMS 4D200 Tap position indicator For use with 2V200 Optional BCD inputs Optional BCD outputs External 12Vdc supply required OLTC position indication

23 TPI Selector Switch RMS 4M900 Up to 22 tap positions Gold plated contact switches One or Two TPI switch gangs Custom mechanical coupling Replace worn tap position contacts to provide reliable tap position indication to SCADA

24 Frequency Relay RMS 2H34-S umatrix digital platform USB programming port 4 stage frequency (81) 4 stage rate of change frequency df/dt (81R) Undervoltage blocking Modbus communication protocol 4M56-S case Load shedding Generator control

25 Synchronism Check Relay RMS 2SY212-S Synchronism Check (25) Adjustable phase angle and time delay Flexible Live and Dead Voltage configuration Bus or Line U/V Close Block Voltage Differential Close Block Frequency Slip Close Block Flexible Synchronism Check Bypass Logic Manual Safe to Close Feature USB programming port Modbus communication protocol 4M56-S case S Safe CB Closure in Generator Installations Sub-transmission and Distribution Auto Reclose Schemes Cogeneration Applications Anti Islanding Schemes

26 Voltage Relay RMS 2V67-S umatrix digital platform USB programming port 1 or 3 phase 4 stage under/over voltage (27/59) Undervoltage blocking Modbus communication protocol 4M56-S case Bus voltage supervision OLTC supervision Generator control

27 Auto Reclose RMS 1B230 1 or 2 shot (79) Adjustable dead timers and reclaim timer Optional reclose counter Shunt initiate input Optional series initiate input CB auxiliary switch input Line voltage interlock input CB spring charged input Safe to close input Drive to lockout input Remote reset input Overhead lines Retrofits

28 DC Intertrip & Supervision RMS 3A300 DC Intertrip & Pilot Supervison Inherent 5kV or 15kV pilot wire isolation Up to 4 ends / stations Continuous or pulse mode pilot supervision Compatible with GCM05 in continuous mode Trip supply supervision Flush or rack mount Size 6 or 8 case Transformer ended feeders Teed feeders Mesh networks

29 Solkor DC Supervision Scheme RMS 3A400 DC Pilot Supervision Inherent 5kV or 15kV pilot wire isolation Continuous or pulse mode pilot supervision Flush or rack mount Size 6 or 8 case Supervision of Solkor protection schemes

30 Trip Relays RMS 2HSM (6RJ) Attracted armature relays (6R Matrix) High speed tripping < 10ms Up to 20 contacts 2M28-S, 4M28-S, 4M56-S case Equivalents to Areva MVAJ CB trip relay Lockout relay Bus zone trip relay CB fail trip relay

31 Auxiliary Flag Relays RMS 6RM (6RA) Attracted armature relays (6R Matrix) Auxiliary speed < 40ms 1 or 2 element versions 3 or 4 element versions also available 2M28-S, 4M28-S, 4M56-S case Equivalents to Areva MVAA Flag relays Repeat relays

32 Trip Circuit Supervision Relays RMS 1TM (6RX) Atttracted armature relays (6R Matrix) Delay on drop-off 2M28-S, 4M28-S case Equivalents to Areva MVAX Trip supply supervision Trip circuit supervision Trip relay supervision

33 New RMS Product Alpha-12 Auxiliary & Tripping Relays

34 Active Burden Module Improve security of low burden, high speed solid state status inputs ABM-48 Provides capacitor discharge protection ESI-48-4 co mpliance Transient noise withstand to IEC60255 Compact & easy to fit Low average operating burden 15ms fixed operate time Wide voltage operating range Thermal cut out protection Operation check LED

35 Trip Circuit Supervision Relays RMS 1X10 Fuse supervision relay (96) RMS 1X20 Trip supply supervision (96) Trip circuit supervision relay with CB closed (74) Delay on drop off RMS 1X30 Trip circuit supervision relay with CB open or CB closed (74) Delay on drop off

36 Voltage Selection Relay RMS 2P48 Phase failure, Phase unbalance, Undervoltage LED incoming and outgoing supply indication 5 C/O contacts Delay on drop off (optional) 4M28-S case Voltage changeover scheme (60)

37 Phase Failure Relay RMS 2P49 Phase failure, Phase unbalance, Undervoltage Rack or Panel Mount 2 C/O contacts TERMINATION 1 Contact 1 Contact P740 PHASE FAILURE RELAY 15% 5% SUPPLY NORMAL SENSITIVITY Unbalanced Voltage 415V 3 Phase 50Hz RMS 2P740 Phase failure, Phase unbalance, Undervoltage DIN rail mount 2 C/O contacts

38 Sensitive Earth Fault Relay RMS 2C138 Upgraded version of 2C137 Improved harmonic rejection characterisitc Non volatile trip LED indication Universal binary input voltage Surface mount PCB design Selectable reset characteristic in same model Configuration code / switches 2M28-S case Feeder SEF Master SEF to enable Feeder SEF Backup SEF Standby SEF

39 Current Check Relay RMS 2C65 Upgraded version of 2C63 & 2C64 Non volatile trip LED indication Universal binary input voltage 8 C/O contacts 3 phase and phase segregated in same model Surface mount PCB design < 15ms pickup / dropout Configuration code / switches 4M56-S case CB fail Definite time overcurrent Instantaneous overcurrent Current guard

40 Digital Time Delay Relay RMS 2T105 Upgraded version of 2T s, 0-9.9s, 0-99s, 0-990s Time delay operate or release in same model 4 C/O contacts Non volatile trip LED indication Universal binary input voltage Surface mount PCB design Configuration code / switches 2M28-S case CB fail timer CB auxiliary switch CB fail Voltage changeover schemes Definite time delays Reset delays

41 Battery Earth Fault Relays RMS 2L10 / 2L11 Attracted armature relays (6R Matrix) High sensitivity Double wound coils operate in series opposition Earth fault (2L10) Positive & negative earth fault (2L11) 2M28-S, 4M28-S case Substation DC battery banks

42 Voltage Relay RMS 2V76 Upgraded version of 2V74 Single phase voltage Selectable under or over voltage Non volatile trip LED indication Universal binary input voltage 5 C/O contacts Surface mount PCB design Configuration code / switches 2M28-S case Voltage changeover scheme (60) 1 stage under or over voltage relay (27, 59) 1 stage neutral displacement (59N)

43 DC Current Sensing Relay RMS 2C81 Shunt operated (mv input range) Instantaneous or time delayed 2 C/O output contacts 2M28-S case DC overcurrent

44 Modular Monitoring Relays TERMINATION Contact 1 Contact P740 PHASE FAILURE RELAY 15% 5% SUPPLY NORMAL SENSITIVITY Unbalanced Voltage 415V 3 Phase 50Hz RMS 700 SERIES 2C720 AC Current 1F701 Flasher 2H750 Frequency 2H760 Frequency 1L710 Liquid Level 2P740 Phase Failure 2T749 Delay Operate Timer 2T751 Delay Release Timer 2T770 Recycling Timer 2TD770 Thermistor 2V730 AC Voltage 2V731 DC Voltage 3Y701 Auxiliary HN B Din Rail Clip

45 Protection Schemes Example: 1S28 Arc Fault Monitor System

46 Mors Smitt Rail Components

47 Mors Smitt Rail Components On-board Relays Measuring Instruments

48 Thank You

6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays Pre-Defined Modular Relays Auxiliary, Trip & Supervision Relays Rugged modular construction Rack or flush mounting Range of function types Draw out module, & 20 contact versions Operating & reset coils

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

2C138. Sensitive Earth Fault Relay. Features. Application. Operation Technical Bulletin 2C138 Sensitive Earth Fault Relay Features High sensitivity (0.1% of I n ) 2 nd & 3rd harmonic & HF noise suppression - tuned to 50 Hz Optional reset functions Instantaneous (Fast),

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation 2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

2H34. Definite Time Frequency Relay with ROCOF. Features. Operation. Application

2H34. Definite Time Frequency Relay with ROCOF. Features. Operation. Application 2H34 Definite Time Relay with ROCOF Technical Bulletin Features Large back lit display panel High resolution frequency & voltage display readout Four independent frequency s Independent time delay per

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

2V67-S Four Stage Over / Under Voltage Relay

2V67-S Four Stage Over / Under Voltage Relay Technical Bulletin 2V67-S Four Stage Over / Under Voltage Relay Features Large graphics display panel Instantaneous voltage display 20 to 130V PU setting range 0.1V setting resolution Adjustable pick up

More information

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Ancillary Electrical Equipment for Use in Conjunction with Switchgear and Protection/Control Panels NOTE: The current version of this document is

More information

7SG26 Tau Autoreclose and synchronization Answers for energy

7SG26 Tau Autoreclose and synchronization Answers for energy Reyrolle Protection Devices SG Tau Autoreclose and synchronization Answers for energy SG Tau Autoreclose and synchronization Fig 1. Tau relay in size 1 case Description The Tau range of auto-reclosing

More information

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays PROTECTION MiCOM P124 Self and Dual Powered Overcurrent Relays MiCOM P124 are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can

More information

TWO-WINDING TRANSFORMER DIFFERENTIAL

TWO-WINDING TRANSFORMER DIFFERENTIAL E3-TR PROTECTION WITH AUTOMATIC VOLTAGE Because of the control, measuring and monitoring functions implemented, the IED can also be used as a bay control unit. The EuroCAP configuration tool, which is

More information

1. Project Description

1. Project Description Page No: 1 of 16 1. Project Description 1.1 Introduction This document outlines protection, monitoring and control requirements for the shared network assets associated with establishment of Tarrone Terminal

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

2V67 Four Stage Over / Under Voltage Relay

2V67 Four Stage Over / Under Voltage Relay Technical Bulletin 2V67 Four Stage Over / Under Relay Features Large graphics display panel Instantaneous voltage display 2 to 13V PU setting range.1v setting resolution Adjustable pick up & drop out Adjustable

More information

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy Reyrolle Protection Devices 7SG118 Argus 8 Voltage & Frequency Relay Answers for energy 7SG118 Argus 8 Voltage and Frequency Relay Data Storage and Communication Serial communications conform to IEC60870-5-103

More information

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy Reyrolle Protection Devices 7SG117 Argus 7 Synchronising Relay Answers for energy 7SG117 Argus 7 Synchronising Relay Fig 1. Independent check & system synchronising settings Adjustable slip frequency,

More information

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field DTRV-EP COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS Application field The DTRV type of complex transformer protection is designed to protect 120 kv / medium voltage transformers,

More information

2V67-S Four Stage Over / Under Voltage Relay

2V67-S Four Stage Over / Under Voltage Relay Technical Bulletin 2V67-S Four Stage Over / Under Relay Features Large graphics display panel Instantaneous voltage display 2 to 13V PU setting range.1v setting resolution Adjustable pick up & drop out

More information

NPW800R RETROFITTING. Power and Volatge Protection Relay

NPW800R RETROFITTING. Power and Volatge Protection Relay RETROFITTING Power and Volatge Protection Relay NPW800R (R3 case) is dedicated to the refurbishment of CEE WTG 7000 relays (R3 case) providing the measurement of apparent (S), active (P) and reactive (Q)

More information

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection SOLKO-N (7S18) Feeder Differential Protection CLASSIFICATION OF UNIT TYPE POTECTION Summation Transformer, Circulating Current Protection B B 3 1 1 O O 3 1 1 SUMMATION TANSFOME SUMMATION TANSFOME O - Operating

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

Auxiliary Units for 7SR23 High Impedance Protection Energy Management

Auxiliary Units for 7SR23 High Impedance Protection Energy Management Reyrolle Protection Devices Auxiliary Units for High Impedance Protection Energy Management Siemens Protection Devices Limited 2 Auxiliary Units for High Impedance Protection Description 7XG15 High Impedance

More information

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent

More information

Content REF615 Technical Presentation

Content REF615 Technical Presentation Distribution Automation Relion 615 series Feeder Protection and Control Ver. 2.0 Technical Presentation March 30, 2010 1MRS756407 E Slide 1 Content Technical Presentation highlights March 30, 2010 Slide

More information

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756407 E Slide 1 Content REF615 Technical Presentation highlights May 13,

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B GE Energy Connections Grid Solutions MMLZ Technical Data Sheet Auxiliary Modules Publication reference: MMLZ/EN TDS/B MMLZ Technical Data Sheet FEATURES Wide choice of application specific models Fully

More information

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9 PJM Manual 07: PJM Protection Standards Revision: 3 Effective Date: May 24, 2018 Prepared by System Planning Division Transmission Planning Department PJM 2018 Table of Contents Table of Contents Approval...6

More information

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays 01 Self and Dual Powered Overcurrent Relays are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can be applied to a wide variety

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic

More information

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68 The Challenges and Opportunities Faced by Utilities using Modern Protection and Control Systems - Paper Unavailable Trends in Protection and Substation Automation Systems and Feed-backs from CIGRE Activities

More information

Feeder/ Motor Protection Relay VAMP 40

Feeder/ Motor Protection Relay VAMP 40 Feeder/ Motor Protection Relay Feeder/motor protection relay Main characteristics Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable

More information

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

Shortform Catalogue Global Suppliers of Measurement and Protection Equipment for Industry >> moving iron >> rectified moving coil

Shortform Catalogue Global Suppliers of Measurement and Protection Equipment for Industry >> moving iron >> rectified moving coil >> moving iron >> rectified moving coil >> frequency meters >> phase sequence indicators >> null voltmeters >> wattmeters >> varmeteers Shortform Catalogue >> power factor meters Global Suppliers of Measurement

More information

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy Reyrolle Protection Devices 7SR11 and 7SR12 Argus Overcurrent Relays Answers for energy 7SR11 and 7SR12 Argus Overcurrent Relays Control 79 Auto Reclose 86 Lockout CB Control Features Cold Load Settings

More information

MiCOM P521. Fast Feeder Differential Protection

MiCOM P521. Fast Feeder Differential Protection 01 Fast Feeder Differential Protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test: Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. designed for feeder automation applications This solution allows very fast fault detection

More information

MiCOM P111. Three phase and earth fault overcurrent relays

MiCOM P111. Three phase and earth fault overcurrent relays Three phase and earth fault overcurrent relays The relays are suitable for all the application where overcurrent and/or earth-fault protection are required. Thanks to its favorable price vs technical features

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

DSP240-LPI Inverter Controller Card. Technical Brief

DSP240-LPI Inverter Controller Card. Technical Brief DSP240-LPI Inverter Controller Card Technical Brief September 2006 Manual Release 3.0 Card Revision 3.0 Copyright 2001-2006 Creative Power Technologies P.O. Box 714 MULGRAVE Victoria, 3170 Tel: +61-3-9543-8802

More information

Reyrolle Catalogue Answers for Energy

Reyrolle Catalogue Answers for Energy Reyrolle Protection Devices Reyrolle Catalogue Answers for Energy Index Compact Overcurrent Argus C 7SR11 & 7SR12 1 Multifunction Overcurrent Argus M 7SR21 & 7SR22 2 Multifunction Reclose Controller Recloser

More information

MiCOM P521. Fast feeder differential protection

MiCOM P521. Fast feeder differential protection 01 Fast feeder differential protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

Protection Products. Catalogue

Protection Products. Catalogue Protection Products Numerical Multi-Function Relays Catalogue Selection Guide Product Range Feeder Protection Model Argus 1 Argus 2 Argus 7 Argus 8 Delta Delta Lite Motor Protection Model Rho 3 Description

More information

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport,

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management Reyrolle Protection Devices 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay Energy Management 7SG21 DDB20 Digital Time Delay Induction disc reset emulation Replacement of induction disc timing

More information

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,

More information

Using the Bitronics 70 Series to Improve Local Monitoring and Control

Using the Bitronics 70 Series to Improve Local Monitoring and Control Automate a Substation and Preserve the Electromechanical Relay Investment Part Two of Four Using the Bitronics 70 Series to Improve Local Monitoring and Control Paul Grabowski - Bitronics Senior Application

More information

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Recloser Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Designed for feeder automation applications This solution allows very fast

More information

Protection and Control REX640 Product Presentation

Protection and Control REX640 Product Presentation ABB OY DISTRIBUTION SOLUTIONS Protection and Control REX640 Product Presentation 1MRS758996 A Product introduction Protection and Control REX640 All-in-one protection for any power distribution application

More information

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date Offshore Spotlight ENERGY Issue 02 Oct 2013 www.siemens.com/reyrolle Current Matters Siemens Protection Devices Ltd Protecting your electrical assets... today and tomorrow The Device issue In-depth looks

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

Application Notes on Generator Protection Schemes

Application Notes on Generator Protection Schemes Application Notes on Generator Protection Schemes Single Line Diagram Examples 1. Introduction The application notes provide selected single line diagrams for the SIPROTEC 4 generator protection device

More information

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation

More information

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A) XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A) Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 PC83 and PC830 series devices are designed to perform the relay protection functions and 6-154 kv networks automation, have different functionality

More information

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

IMP/ 001 / 014 Policy for the Protection of Distribution Networks Version:- 1.1 Date of Issue:- July 2016 Page 1 of 39 IMP/ 001 / 014 Policy for the Protection of Distribution Networks 1. Purpose The purpose of this document is to detail the network protection philosophy

More information

XG2 Generator-/Mains Monitor. Manual XG2 (Revision A)

XG2 Generator-/Mains Monitor. Manual XG2 (Revision A) XG2 Generator-/Mains Monitor Manual XG2 (Revision A) Woodward Manual XG2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data SYMAP R Plug in Variants FI, MI, 87M, TI Technical data 1 Product overview SYMAP R (Retrofit) is a digital protection relay for use in medium and high-voltage power systems. Because of its integrated protection

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL BE1-851E ENHANCED OVERCURRENT PROTECTION SYSTEM DEVICE FUNCTIONS 43 50 51 62 The BE1-851E is an enhanced overcurrent protection system based on the design of the BE1-851, a multifunction, numeric relay

More information

GRD110 FEATURES APPLICATION

GRD110 FEATURES APPLICATION FEATURES Overcurrent protection for phase and earth faults with IDMTL or DTL. Three instantaneous elements with DTL. Programmable reset characteristics. Sensitive earth fault protection (SEF). Restricted

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information

ABM Status Input Active Burden Module

ABM Status Input Active Burden Module Technical Bulletin ABM Status Input Active Burden Module Features Improve security of sensitive, high speed digital status inputs Provides capacitor discharge protection for solid state status inputs to

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication BE1-851 OVERCURRENT PROTECTION SYSTEM The BE1-851 is a multifunction, numeric relay that provides three phase, ground, and negative sequence overcurrent protection with four shot recloser, breaker failure,

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Numerical motor protection in medium voltage networks Motor Protection and Control REM620 Guideform Specification 1MRS758530 A Numerical motor protection in medium voltage networks Motor Protection and Control REM620 The configurable motor management relay is intended for protection, control,

More information

Power Test Equipment

Power Test Equipment Power Test Equipment for the global power industry T&R Test Equipment design and manufacture high quality test equipment for the power industry. Our equipment is used world-wide in transmission and distribution,

More information

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A) IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

Three phase and earth fault overcurrent relays

Three phase and earth fault overcurrent relays 01 Three phase and earth fault overcurrent relays The relays provides features for easy adaptation and are suitable for all applications where overcurrent and earth-fault protection are required. The MiCOM

More information

Siprotec 7ST61 / 7ST63

Siprotec 7ST61 / 7ST63 Siprotec / Numerical overhead contact line protection for AC traction power supply siemens.de/rail-electrification The numerical overhead contact line protection relay Siprotec / is a selective and quick

More information

Feeder protection relay

Feeder protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay modules and a flexible

More information

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are

More information

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756901 A Slide 1 Content RET615 Technical Presentation highlights May

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

Feeder protection relay SPAA 341 C. Product Guide

Feeder protection relay SPAA 341 C. Product Guide Issued: April 1999 Status: Updated Version: D/07.03.2006 Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays Maximize protection Sepam series 10, 20, 40, 60, 80 Modular range of digital protection relays Fast Dependable Simple Increase energy availability 100% available energy Fast response Maximum dependability

More information

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator

More information

Reyrolle Protection Devices. 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard. Answers for energy

Reyrolle Protection Devices. 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard. Answers for energy Reyrolle Protection Devices 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard Answers for energy 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection

More information

GPM500 Generator Protection Module

GPM500 Generator Protection Module GPM500 Generator Protection Module Generator Protection Module GPM500 The microprocessor based Generator Protection System GPM500 performs the protection and control of medium and low voltage generators

More information

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION Field of application The devices of the EuroProt complex protection family are modular devices. The modules are selected, assembled and

More information

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks GUIDEFORM SPECIFICATION Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks The freely configurable relay is intended for protection, control, measurement

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information