Tap Manager TM100. Operating Instructions

Size: px
Start display at page:

Download "Tap Manager TM100. Operating Instructions"

Transcription

1 Tap Manager TM100 Operating Instructions

2 2

3 Contents Contents 1 General Safety instructions Application Design Controls Scroll keys in display field Enter key Local/Remote switch Raise/Lower keys Displays LCD display LED displays Diagnosis interface Modules Network filter module Power supply module Control module Temperature measuring module Position module Power measuring module CPU module Front bus-board External connections of the standard device Technical data Environmental conditions Housing, dimensions, weight Power supply Measuring ranges Relays (control of output contacts) External digital inputs Operation Drive control Starting a tap-change operation Blocking a tap-change operation Local acknowledgement of alarms and warnings Drive monitoring Monitoring during the tap-change operation Monitoring during resting Wrong phase sequence Hand crank operation NOTE Data contained herein may differ in small details from the unit delivered. We reserve the right to make alterations without notice. 3

4 Contents Contents 3.4 Monitoring of limit values Torque monitoring Temperature monitoring Contact wear Replacement of parts Oil change Data storage Storage principle Event memory Raw torque data evaluated torque data Wear data Temperature data Current data Maintenance display General information on maintenance Appendices NOTE Data contained herein may differ in small details from the unit delivered. We reserve the right to make alterations without notice. 4

5 1 General 1 General 1.1 Safety instructions 1.2 Application All personnel involved in installation, commissioning, operation and maintenance of the device must - be suitably qualified and - strictly observe these Operating Instructions. Improper operation or misuse can lead to - serious or fatal injury, - damage to the device and other property of the user, and - a reduction in the efficiency of the device. Safety instructions in this manual are presented in three different forms to emphasize important information. WARNING This information indicates particular danger to life and health. Disregarding such a warning can lead to serious or fatal injury. The electronic on-load tap changer monitoring system TM100 controls, monitors and records data from motor drive units and high voltage on-load tap-changers. The advantages of the TM100 include early detection of faults and the possibility for condition-dependent tapchanger maintenance. Activating the motor drive, which operates according to the step-by-step principle, results in a voltage change of one step on the transformer. During the tap-change operation switching-relevant events are recorded and and limit values such as the torque are monitored. If any faults are detected or if critical limit values are exceeded the subsequent tapchange operation is blocked. During a tap-change operation the motor drive can be blocked by real-time monitoring modules. The events are stored and a message is sent. The device is equipped with a 2-MB memory card for storing parameters and data sets on the on-load tapchanger and motor drive operating values. The data recorded can be read from a serial interface and processed by a visualisation program. The limit value parameters can be changed using the diagnosis or monitoring interface and can be stored in the nonvolatile flash memory on the memory card. CAUTION This information indicates particular danger to the device or other property of the user. Serious or fatal injury cannot be excluded. NOTE These notes give important information on a certain subject. CAUTION The monitoring system and memory card may only be used with the on-load tap-changer specified in the order. Installation, electrical connection and commissioning must only be carried out by qualified personnel according to these Operating Instructions. It is the responsibility of the user to make sure that the device is used for the specified application only. For safety reasons, unauthorized work such as installation, modification, alteration, electrical connection or commissioning of the equipment must not be carried out without first consulting MR! The trouble-free operation of the motor drive, the onload tap-changer and the transformer may be put at risk. CAUTION All relevant fire protection regulations must be strictly observed. 5

6 MANUAL CONTROL MODE OF OPERATION STATUS LINE READY TAP CHANGE END POSITION REACHED HAND CRANK OPERATION ATTENTION CALL SERVICE! WARNING! FAILURE 2 Design 2 Design The device is delivered in a standardized 19 rack according to DIN (fig. 1). 2.1 Controls Scroll keys in display field Using the scroll keys (fig. 3) the important operating data can be displayed, e.g. number of tap-change operations, end positions, operating current of the onload tap-changer, temperature, time and date. TM100 OLTC - MONITORING - SYSTEM DATA PORT RS232 SCROLL INPUT SCROLL REINHAUSEN MRGERMANY LOCAL REMOTE MADE IN GERMANY DATA PORT SCROLL INPUT RS232 MANUAL CONTROL MODE OF OPERATION STATUS LINE READY TAP CHANGE LOCAL REMOTE END POSITION REACHED HAND CRANK OPERATION ATTENTION CALL SERVICE! WARNING! FAILURE 1 KHW KHW 1147 The design is modular, which means the individual functions are performed by individual modules. The front plate contains the controls and a two-line LCD display. The RS232 diagnosis interface is connected to a 9-pole sub-d socket. All components on the front are soldered onto a busboard which is also a connecting board for the individual electronic modules. All electronic modules are plugged into the rear of the device and are mechanically locked in their positions by EMC barriers (fig. 2) Enter key This key can be used to acknowledge an event or error message code (fig. 4). The acknowledged code is explained in a reference list which is included with the connection diagrams. INPUT 2 KHW KHW

7 2 Design Local/Remote switch (fig. 5) This slide switch is used to select the Local or Remote mode of operation. Tap-change operations can only be activated by the control keys on the TM100 when Local mode is selected. 2.2 Displays LCD display With trouble-free operation and when the motor drive is in the resting range (grey field on the tap-change indicator), the first line (fig. 7) shows that the on-load tap-changer is ready for an operation. The second line shows the tap position and number of sections on the tap-change indicator of the motor drive. MODE OF OPERATION LOCAL REMOTE 5 KHW KHW 1151-S Raise/Lower keys (fig. 6) These keys are used to initiate an on-load tap-change operation in manual mode in either the Raise or Lower direction. When a message is generated by the monitoring system, it is displayed as an event code number. This also occurs with alarms and warnings (fig. 8). MANUAL CONTROL 6 KHW KHW 1151-W 7

8 2 Design LED displays (fig. 9) Ready (green) The device is switched on and the tap position input is correct. Tap-change operation (yellow) A tap-change operation is in progress ( running indication) End position reached (yellow) The on-load tap-changer is in one of its two end positions. Hand crank operation (yellow) The hand crank is fitted. The switching sequence is no longer monitored. Attention! Call Service! (yellow) Alarms are present. Tap-change operation is still possible. Warning! Failure (red blinking) A warning is present. Tap-change operation is not possible until the warnings are acknowledged. 2.3 Diagnosis interface (fig. 10) Using this RS232 interface, data can be read and settings altered locally by means of the MR visualisation program. DATA PORT RS STATUS LINE READY 9 TAP-CHANGE END POSITION REACHED HAND CRANK OPERATION ATTENTION! CALL SERVICE! WARNING! FAILURE 2.4 Modules Network filter module This module contains a network filter. In AC design it additionally contains the voltage setting of 100 V AC up to 260 V AC, and in DC design a chopper unit Power supply module AC design: Rated voltages of 100 V, 110 V, 120 V, 130 V, 200 V, 210 V, 220 V, 230 V, 240 V, 250 V and 260 V AC can be set via winding taps on the network filter module. DC design: Thanks to prewired winding taps, power supply units with 110 V, 125 V, 200 V, 220 V, 250 V are available Control module This module contains 8 optocoupler inputs. The optocouplers are operated with a 30 V control voltage provided by the module. There are 4 relays for controlling the switchgear, each with an N/O contact and one common terminal. 8

9 2 Design Temperature measuring module This module contains 4 measuring channels for the MR digital temperature sensors. The temperature sensors are interrogated via an interface with signal levels according to RS 485. A sensor on the module measures the internal temperature of the unit Position module This module reads the position of the on-load tapchanger and tap selector contacts. A rotary transmitter attached to the position transmitter shaft in the motor drive supplies an absolute-position signal Power measuring module This module measures the motor current and motor voltage and prepares the values correctly phased for the analog/digital conversion. The CPU determines a power value from 200 real-time samples taken during each period which is then converted by a transmission function into an on-load tap-changer torque value CPU module This is the core of the system. It processes the measured values, controls and monitors the other modules and operates the motor drive control. The CPU module contains the memory card (see BA 188, section 4.2) as non-volatile data memory and also may have two fibre-optic interfaces. Transmission range at 660 nm wavelength: < 100 m Transmission range at 850 nm wavelength: 1500 m Front bus-board The front bus-board is located behind the front panel and connects the modules. The controls, displays and signalling lights are mounted on and connected to it External connections of the standard device X22 Power supply X24, X26 Control board 1 X25, X27 Control board 2 X38 Temperature measuring board X40 Position input board X34 Power measuring board 2.5 Technical data Note: Only values indicating tolerances or limits can be considered guaranteed data. Values without tolerance details are for information only and are not guaranteed. 2.6 Environmental conditions Temperature range -25 C C Degree of protection IP Housing, dimensions, weight Housing according to DIN Teil 5 Height 132,5 mm Width 483 mm Depth 180 mm Weight ca. 12 kg (with max. equipment) 2.8 Power supply 230 V AC, -15 % bis +10 %, for settings see Measuring ranges Temperature measuring board: Measuring range: -30 C to 100 C, accuracy ± 1.2 C -45 C to 130 C, accuracy ± 2 C Power measuring board: AC: 260 V, 6 A 520 V, 6 A DC: 300 V, 7 A 2.10 Relays (control of output contacts) N/C contacts with common terminal (each board with 4 relays) 240 V AC, 8 A 30 V DC, 5 A 110 V DC, 0.4 A 250 V DC 0.3 A External digital outputs are connected via coupling relays and are wired as electrically-separate changeover contacts to the terminal strip X1 of the motor drive but only if the TM100 wiring is carried out by MR External digital inputs External digital inputs are electrically separated by coupling relays. Control voltage of coupling relays: 230 V AC. An auxiliary voltage (30 V DC) provided by the TM100 is switched via potential-free contacts to TM100 inputs (see 2.4.3). 9

10 3 Operation 3 Operation 3.1 Drive control Starting a tap-change operation Local mode operation: When the Local/Remote switch is in Local position (fig. 11) and when the display shows OLTC ready (fig. 12), a tap-change operation can be initiated, e.g. towards position 27 or towards position 1, using the Raise or Lower keys, respectively. Exception: Hand crank operation: If the motor drive is operated by the hand crank past the resting range to the point that a step-by-step switch is triggered, the initiated tap-change operation is automatically completed Blocking a tap-change operation 11 MODE OF OPERATION LOCAL REMOTE KHW 1149 Remote mode of operation: When the Local/Remote slide switch is in the Remote position and when the display shows OLTC ready, a tapchange operation can be initiated, e.g. towards position 27 or towards position 1, by a control voltage pulse (ca. 0.5 s) applied to terminal X1.10 or X1.11 respectively. An initiated tap change-operation is blocked under the following circumstances: a warning is present which is indicated by the blinking red LED Warning! Event!, an end position is reached but the next tap-change operation intended is in the same direction, the hand crank is fitted, the factory-set maximum permissible tap-changer current is exceeded, the maximum permissible temperature range is exceeded Local acknowledgement of alarms and warnings In the Local mode of operation a warning or alarm displayed as the event number (fig. 13) can be acknowledged by pressing the Enter key. Schalter bereit 13 KHW 1151-W 12 KHW 1151-S If several warnings and alarms occur at the same time, the warnings are shown first and then the alarms. The sequence is determined by the code number. The message with the highest code number must be acknowledged first. 10

11 3 Operation 3.2 Drive monitoring Monitoring during a tap-change operation During a tap-change operation the motor drive running time and the movement of the drive shaft in the motor drive are monitored (also see 3.4.1). If the running time is exceeded, an error message is sent and the motor protective switch is tripped. WARNING If the maximum torque of the on-load tap-changer is exceeded during a tap-change operation and the motor drive is immediately stopped, MR s Technical Service should be informed. Serious damage may occur to the on-load tapchanger. Disregarding this warning can lead to serious damage to property or serious or fatal injury Monitoring during resting After completion of the tap-change operation the motor drive is monitored to ensure the motor does not continue running after its slow-down period. If, due to a sticking contactor, the motor continues running without control the motor protective switch is tripped Wrong phase sequence The TM100 monitors the direction of rotation of the motor drive and trips the motor protective switch if the direction of rotation is wrong. In addition, it sends the error message Wrong direction of rotation. After the error is corrected and the message is acknowledged the motor drive completes the initiated tap-change operation. 3.3 Hand crank operation If the hand crank safety switch signals that the hand crank is fitted, the TM100 changes to hand crank operation. The automatic drive control and monitoring are not in operation when the hand crank is used. The on-load tap-changer can be operated to any position within the mechanical limits. If the hand crank is withdrawn outside the neutral zone or in a position to be passed, the initiated tap-change operation is automatically completed. 3.4 Monitoring of limit values CAUTION If the motor drive is operated when the red alarm is activated, serious damage to the motor drive, on-load tap-changer and transformer can occur Torque monitoring The on-load tap-changer torque is monitored in real time during a tap-change operation. If the set maximum torque is exceeded, the tap-change operation is immediately stopped and the motor protective switch is tripped. At the end of each tap-change operation the recorded torque measurement points are evaluated. The maximum torques in each section of the tap-change operation are compared to the corresponding limit values and, if necessary, alarms and warnings are sent. If none of the limit values are exceeded, the on-load tap-changer is ready for a new operation and the display shows OLTC ready Temperature monitoring When the TM100 is switched on, the following temperatures are measured: oil temperature in the on-load tap-changer oil compartment transformer oil temperature and, in bolt-on tapchangers, the tap selector temperature external temperature internal temperature in the TM100 electronics. If the actual values exceed or fall below the limit values, corresponding alarm or error messages are sent. Deviations or below the temperature thresholds can block the operation of the on-load tap-changer. Yellow: Operation can continue (without acknowledgement of message) Red: Operation can continue only after acknowledgement of message. The motor drive control is blocked. If the difference between the internal and external temperature exceeds 8 Kelvin and if the internal temperature is less than 10 C, the heater is switched on. 11

12 3 Operation Contact wear The wear of the switching and resistor contacts of the diverter switch is determined from the on-load tapchanger current. After each tap-change operation the contact wear is calculated from the on-load tap-changer current using an algorithm. If the permissible wear is exceeded, a warning is sent and the on-load tap-changer is blocked. If the contact wear reaches 90 %, an alarm (yellow) appears. An imminent technical service should be planned Replacement of parts The precautionary replacement of parts depends on the number of switching operations. The corresponding data is stored in the TM100. When 90 % of the number of operations is reached, an attention signal (yellow signal) appears to indicate that a parts replacement service should be planned. In this case please contact the MR Technical Service Oil change The criteria are stored in the TM100. When 90 % of the criteria is reached, an attention signal (yellow signal) appears. Together with the oil change it is necessary to clean and inspect the diverter switch oil compartment and diverter switch insert. For details refer to the inspection instruction manual for the respective on-load tap-changer. If the on-load tap-changer is operated with an MR oil filter plant, the response pressure of the filter plant is the criterion for the filter cartridge replacement. This is also signalled by the TM100. For the criteria of the diverter switch oil change refer to the operating instruction manual for the MR oil filter plant. 3.5 Data storage Storage principle Data is stored on a PCMCIA memory card. There are two memory blocks for data which are rewritable. If both blocks are full, the block with the older data is deleted. Essential operational data such as parameters, alarms and error messages, wear data and faulty torque characteristics are stored in memory areas which are non-rewritable Event memory All events are stored with a time stamp in the rewritable memory area. The memory capacity is 2 blocks with events each which are alternately rewritable. In addition, attention and warning messages are stored in a non-rewritable space of the Memory Card Raw torque data The torque measurement points from each tap-change operation together with essential operation data such as tap position, tap-change operation type, temperature, motor voltage and on-load tap-changer current are stored in a rewritable memory area. The memory capacity contains 2 blocks which are alternately rewritable. If limit values are exceeded, the data set is additionally stored in a non-rewritable memory area Evaluated torque data After completion of a tap-change operation the torque data is evaluated according to the type of tap-change operation and the corresponding functional sequence in the on-load tap-changer. The maximum torques during each tap change operation are used by the monitoring system to analyse the functional sequence in the onload tap-changer mechanics and as a comparison against specified limit values. The data set created is stored. 12

13 Operation 3 Appendices Wear data 3.6 Maintenance display From the specified transformer step voltages, the onload tap-changer current at the moment of the tap change and from known characteristics of the contact material, the monitoring system calculates the wear of the switching and resistor contacts on the on-load tapchanger using a mathematical model. The results are stored and used to evaluate wear differences between the individual contacts and the total wear. In connection with the limit values of the diverter switch to be monitored the system monitors the condition of the contacts subject to wear Temperature data As well as constantly monitoring the on-load tapchanger temperature, the measured temperatures are periodically stored. In addition, the minimum, maximum and average temperature values are stored at the end of each calendar day Load current data If the specified number of operations is reached, or if a service is required, the monitoring system issues and sends corresponding messages. If operating conditions are such that continuing operation jeopardises the equipment, the monitoring system blocks the motor drive. 3.7 General information on maintenance Maintenance measures can be carried out with minimum expense. They can be effectively combined with the usual control checks on the transformer. Visually checking the motor drive Checking the protective function of the protective relay of the on-load tap-changer Checking the on-load tap-changer oil Checking the silicagel breather Refer to the respective Operating Instructions of the individual on-load tap-changers for details on limit values. The monitoring system can measure the on-load tapchanger current from different sources. This current value is required to calculate the contact wear. However, it is also stored in the same way as the tem-perature value so that minimum, maximum and average current values are available for evaluation. 4 Appendices Front view with control... TM_FRTEN Rear view with plug designations... TM_BGTRU Block diagram... TM100B1D Block diagram... TM100B2D Block diagram... TM100B3D Circuit diagram... ZM0004S1 Circuit diagram... ZM0004S2 Circuit diagram... ZM0004S3 Circuit diagram... ZM0004S4 13

14 4 Appendices Tap Manager TM100 Front view with controls TM_FRTEN.PIC 14

15 4 Appendices Option: Modem, STE3, TX1, TX2, RX1, RX2 Tap Manager TM100 Rear view with plug designations TM_BGTRU.PIC 15

16 4 Appendices Tap Manager TM100 Block diagram TM100B1E 16

17 4 Appendices Tap Manager TM100 Block diagram TM100B2E 17

18 4 Appendices Tap Manager TM100 Block diagram TM100B3E 18

19 4 Appendices Motor Drive Unit ED Monitoring ZM0004 Circuit diagram Sheet 1 19

20 4 Appendices Motor Drive Unit ED Monitoring ZM0004 Circuit diagram Sheet 2 20

21 4 Appendices Motor Drive Unit ED Monitoring ZM0004 Circuit diagram Sheet 3 21

22 4 Appendices Motor Drive Unit ED Monitoring ZM0004 Current Diagram Sheet 4 22

23 23

24 Maschinenfabrik Reinhausen GmbH 2001 Postfach Regensburg Germany Phone: (+49) 9 41 / Fax: (+49) 9 41 / Internet: sales@reinhausen.com BA 189/01 en /1000 F Printed in Germany

TAPCON 240 Voltage Regulator for Regulating Transformers

TAPCON 240 Voltage Regulator for Regulating Transformers www.reinhausen.com TAPCON 240 Voltage Regulator for Regulating Transformers TAPCON The next generation of voltage regulators TAPCON : a name which is synonymous for an entirely new and ground-breaking

More information

TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS.

TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS. TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS. WWW.REINHAUSEN.COM TAPCON 250 TAPCON 250 THE NEW GENERATION OF VOLTAGE CONTROLLERS. For more than 40 years voltage

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Analog display for resistance current

Analog display for resistance current www.reinhausen.com Analog display for resistance current Operating Instructions BA 2220061/01 NOTE The product may have been modified after this document went to press. We expressly reserve the right to

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Trafoguard reliable monitoring of Transformer operating statuses. Transformer control

Trafoguard reliable monitoring of Transformer operating statuses. Transformer control Trafoguard reliable monitoring of Transformer operating statuses. Transformer control 2 Trafoguard Trafoguard money can't buy a better way of ensuring economic Transformer operation. Trafoguard Trafoguard

More information

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

tapcon 230 user-friendly, FleXiBle and reliable. transformer control tapcon 230 user-friendly, FleXiBle and reliable. transformer control Tapcon 230 tapcon 230 the new standard in voltage control. 2 Maschinenfabrik Reinhausen (MR) has been developing and manufacturing voltage

More information

RER 123 Bus Connection Module. Technical Description

RER 123 Bus Connection Module. Technical Description Bus Connection 1MRS751143-MUM Issued: 06.11.1998 Version: E/08.07.2005 Bus Connection 1. About this manual...4 1.1. Copyrights...4 1.2. Trademarks...4 1.3. Guarantee...4 2. Safety information...5 3. General...6

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Assembly and Operating Instructions. M2 module for BDC-i440 control units BDC-i440 M2 en Assembly and Operating Instructions M2 module for BDC-i440 control units Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual Control Cabinet Inverter MOVITRAC B Functional Safety Edition 05/2009 16811216 / EN SEW-EURODRIVE Driving the world Content Content

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this

More information

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300 Monitoring Technique VARIMETER PRO Multifunction Measuring Relay MK 93N, MH 93 268581 Product description MK 93N MH 93 The universal measuring relays MK 93N / MH 93 of the VARIMETER PRO series monitor

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

TAPCON 230 Voltage Regulator for Regulating Transformers

TAPCON 230 Voltage Regulator for Regulating Transformers www.reinhausen.com TAPCON 230 Voltage Regulator for Regulating Transformers TAPCON Voltage regulators of the next generation TAPCON : a name which stands for a completely new range of voltage regulators

More information

Transponder card reader

Transponder card reader 6 337 HOTEL SOLUTION Transponder card reader HTR3.1/B Transponder card reader for hotel-room access control Touch-free recognition of access code on transponder card Transfer of access code to HRC3.. room

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL Circuit Breaker Failure Relay Operating Principle Revision: 2 from 2005-02-25 Edition: 2005-02-25 _CBF-description_eng.doc Page 1 /14 Table of Contents: 1 GENERAL DESCRIPTION 4 2 FUNCTIONAL DESCRIPTION

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

HST -TZ1 Guard-locking mechanism (Translation of Original Manual) Installation and Operating Manual for Components HST -TZ1 Guard-locking mechanism (Translation of Original Manual) HST-TZ1 Ident.-No.: 10234 HST-TZ1 Ident.-No.: 10236 HST-TZ1 Ident.-No.: 10235 HST-TZ1

More information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Digital Thermometers. Model: DTM Operating Instructions for Digital Thermometers Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual. GTL - Configuration tool. Please keep the manual for future use. Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33

More information

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. Rotary Encoder Solutions Limited Dutton Road Redwither Business

More information

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date: Operating instructions for AX5801 TwinSAFE drive option card for the AX5000 servo drive Version: 1.2.0 Date: 2016-03-15 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the manual 3 1.1.1

More information

MSENSE BM MONITORING FOR BUSHINGS.

MSENSE BM MONITORING FOR BUSHINGS. MSENSE BM MONITORING FOR BUSHINGS. WWW.REINHAUSEN.COM MSENSE BM Monitoring of three high-voltage bushings with reference system Voltage transformer (high-voltage side) ΔC1comp Δtan δ1comp t MSENSE BM t

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

Monitoring system TAPGUARD 240. Operating Instructions 244/04

Monitoring system TAPGUARD 240. Operating Instructions 244/04 Monitoring system TAPGUARD 240 Operating Instructions 244/04 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and communication of its contents

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 10/2009 Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used

More information

VMD420-DM Voltage and frequency monitor

VMD420-DM Voltage and frequency monitor EN Manual VMD420-DM Voltage and frequency monitor for monitoring of 3(N)AC systems up to 0 500 V for undervoltage and overvoltage and under and overfrequency Software version: D238 V2.2x VMD420-DM_D00227_01_M_XXEN/07.2015

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual Valid for item nos.: 68030.001 (1-zone) 68030.002 (2-zone) 68030.004 (4-zone) 68030.006 (6-zone) HPS-C-Slot Hotrunner controllers Operating manual 2 Content Safety instructions...3 Introduction...4 Operating

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Transponder card holder

Transponder card holder 6 336 HOTEL SOLUTION Transponder card holder HTH3.1/B Transponder card holder for identification of room occupancy status Touch-free recognition of access code on transponder card Transfer of access code

More information

Lightning Stitch Assembly

Lightning Stitch Assembly ABM International, Inc. 1 1.0: Parts List Lightning stitch motor and drive assembly (Qty. 1) Lightning stitch piggy backed controller board assembly (Qty. 1) Touchscreen (Qty. 1) 2 9-pin Serial cable (Qty.

More information

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E s General Information 1 Connection 2 Automatic Transfer Controller User Interface 3 Menus 4 Remote Control Software Manual Edition 01/2010 A5E02469028-01 Legal information Warning notice system This manual

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

Safe monitoring relays

Safe monitoring relays monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator

More information

SM100. On-Line Switchgear Condition Monitoring

SM100. On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return ctuating drive with spring return DSFY/16 Modulated actuating drive with spring return Issue date: Feb. 27, 2006 Subject to change Contents Page Information about the device description... 2 Qualified

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

English. Operating manual. Limit switch GS125.  Keep for future reference. Ventures / brands of GHM English Operating manual Limit switch GS125 Ventures / brands of GHM www.ghm-messtechnik.de Keep for future reference. Table of contents Page 1. Intended use (areas of application)... 3 1.1 Safety signs

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) XPSMCMx Fieldbus Expansion Modules EAV8283001 12/2014 XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) 12/2014 EAV8283001.00 www.schneider-electric.com The information provided

More information

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

igus motion Plastics dryve D3, DC-Motor Control System

igus motion Plastics dryve D3, DC-Motor Control System igus motion Plastics dryve D3, DC-Motor Control System Manual V 1.1 Website Shop www.igus.eu/d3 Videos/Tutorials www.igus.eu/dryve/tutorial Operating Manual dryve D3 - V1.1 1/15 Table of contents Table

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Product Specifications

Product Specifications Product Specifications VIBROCONTROL 6000 Monitoring System Description of Functionality Overview The VIBROCONTROL 6000 Monitoring System is used for both stand-alone machine protection and condition monitoring

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

DRS-LIGHT. Device Description DRS-LP824. Digital Unit Decoupling Relay Type DRS-LP824. Device Description DIL

DRS-LIGHT. Device Description DRS-LP824. Digital Unit Decoupling Relay Type DRS-LP824. Device Description DIL DRS-LIGHT Digital Unit Decoupling Relay Type DRS-LP824 Device Description Edition:09.05.2008 SLLR_LP824_e.doc Page 1 /10 CAUTION Installing, commissioning and operating of this product may be performed

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control Tapcon tapcon VOLTAGE REGULATION FOR TOMORROW S CHALLENGES. 2 For more than 40 years voltage regulators of the tapcon series have stood for

More information

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler

More information

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Electrical network protection Sepam series 20 Sepam series 40 Quick start 03146790FE+01+NP00000000 Electrical network protection Sepam series 20 Sepam series 40 Quick start PE50465 Storage Sepam may be stored in its original packaging in a closed sheltered location: b ambient

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information