Intersection Preassembled Backplate DC

Size: px
Start display at page:

Download "Intersection Preassembled Backplate DC"

Transcription

1 Intersection Preassembled Backplate DC The intersection preassembled backplate arrives fully assembled, wired and ready to be installed in a traffic cabinet. The backplate provides communications, power conversion and surge protection for two or four SmartSensor Matrix or dvance units. Features Provides off-the-shelf support for your SmartSensor Matrix or dvance installation Includes terminal blocks and surge suppression for a complete in-cabinet assembly Comes preassembled on a traffic cabinet backplate for easy installation into existing traffic cabinets Color-coded terminal blocks match colors on SmartSensor 6-conductor cable for foolproof cable landing Provides protection against lightning electrostatic surges on power inputs and on sensor cables Convenient grounded terminal block for backplate protection Preassembled, prewired and tested for first-try functionality Insulation displacement terminal blocks for no-fuss cable termination Two models available: Two-sensor backplate Four-sensor backplate 1 DC Surge OK TD DC Surge OK TD 4 VDC 8 mp Surge Protection PWR RS-485 Bridge RD PWR RS-485 Bridge RD 8.0 DC Present / Protection OK RS-485 B RS-485 B RS-485 RS-485 System Surge Protection System Surge Protection Green/Yellow GND GND B -485B B -485B 1 x C -485C +485D -485D +485C -485C +485D -485D DC+ DC- PE PE DC+ DCx PE PE X X X 4 VDC SSMatrix # SSMatrix # 10-0 DC+ DC- DRN PE PWR GND DRN PWR GND DRN SSMatrix # 10-0 SSMatrix # PWR GND DRN PWR GND DRN WX

2 Technical Specifications ssembly Components: Two-sensor Plate Click 10-0 circuit breakers 1 Click 1 DC surge protector 1 Click system surge protector 5 T-bus connectors (power and communication) 1 T-bus connector (power only) end brackets with labels 1 end bracket without label 4 terminal blocks for C line input: spring cage to plug spring cage 10 WG ( grounded) 14 terminal blocks for cable termination: insulation displacement to plug insulation displacement ( grounded) platform: traffic cabinet backplate 1 8-ft. 14 awg ground cable 1 5-ft. black RJ-11 patch cable 5-ft. white RJ-11 patch cables ssembly Components: Four-sensor Plate 4 Click 10-0 circuit breakers 1 Click 1 DC surge protector Click system surge protectors 6 T-bus connectors (power and communication) 1 T-bus connector (power only) 5 end brackets with labels 1 end bracket without label 4 terminal blocks for C line input: spring cage to plug spring cage 10 WG ( grounded) 8 terminal blocks for cable termination: insulation displacement to plug insulation displacement (4 grounded) platform: traffic cabinet backplate 1 8-ft. 14 awg ground cable 1 5-ft. black RJ-11 patch cable 4 5-ft. white RJ-11 patch cables Click 10-0 Specifications Weight: 0.07 lbs. (1.8 g) dimensions: 0. in. x.5 in. x.4 in. (0.08 cm x 6.4 cm x 8.6 cm) mbient operating temperature: -4 F to 140 F (-0 C to 60 C) Nominal operating voltage: 50 VC, 65 VDC Click 10-0 nominal current: Ordering Information Intersection preassembled backplate DC Two-sensor backplate SS-B Intersection preassembled backplate DC Four-sensor backplate SS-B CCESSORIES CLK-11/114 Click 11/114 rack cards Wavetronix 78 East 1700 South Provo, UT sales@wavetronix.com Two screw terminals for wiring in and out Configuration Feature Push-button used to reset device after a current interruption Fuse Slow-blow fuse Switching Capacity Switching capacity: 6x for nominal currents 0.5 to 4, 8x for nominal currents 6 to 10 Life Expectancy Life expectancy: 000 cycles Passes manufacturer s test before shipping Extended Support Extended support options are available from Wavetronix; contact a Wavetronix representative for more information Click 1 Specifications Weight: 0.4 lbs. (0. kg) dimensions: 4.5 in. 4 in. 0.9 in. (11.4 cm x 10.

3 cm x. cm) mbient operating temperature: -9 F to 165 F (-4 C to 74 C) Humidity: up to 95% RH Hot-swappable Ratings Maximum working voltage: 8 V Maximum continuous operating current: 8 Four screw terminal connections: DC+, DC-, two protective earth 5-position connector for connecting power from the T-bus Configuration Feature LED for monitoring power and surge protection status: indicates that DC power is present, that the polarity is correct, and that the MOV protection devices are functioning correctly Surge Protection Three-stage surge protection: MOV/gas tube hybrid; inductors and TVS diodes; inductors and TVS diodes Complies with the applicable standards stated in the IEC class 4 standard for DC power lines Test results available for the following test conditions: surge voltages ±0.5kV, 1kV, kv and 4kV; common mode (input to ground); differential mode (input to input); 8x0μs waveform; ohm generator impedance; minutelong pause between surges NEM TS-1998 Complies with the applicable standards stated in the NEM TS-1998 Standard Test results available for each of the following tests: 00 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage; stored at -49ºF (-45ºC) for 4 hours; stored at 185ºF (85ºC) for 4 hours; operation at -9.ºF (-4ºC) and 10.8 VDC; operation at -9.ºF (-4ºC) and 6.5 VDC; operation at 165.ºF (74ºC) and 6.5 VDC; operation at 165.ºF (74ºC) and 10.8 VDC Passes manufacturer s test before shipping Extended Support Extended support options are available from Wavetronix; contact a Wavetronix representative for more information Click Specifications Weight: 0.5 lbs (0.15 kg) dimensions: 4.5 in. 4 in. 0.9 in. (11.4 cm x 10. cm x. cm) mbient operating temperature: -9 F to 165 F (-4 C to 74 C) Humidity: up to 95% RH Hot-swappable Pluggable screw terminals for easy pre-wiring: 1 pair for DC power, terminals for protective earth, 4 pairs for RS-485 communication (485, 485B, 485C, 485D) RJ-11 jacks for connecting to detector rack cards: one connected to 485, one to 485B, one to 485C and 485D 5-position connector for power and RS-485 to and from the T-bus Communications Routes RS-485 communications between screw terminals, 5-position connector, and RJ-11 jacks RJ-11 jacks labeled RS-485 and RS-485 B send contact closure information to rack cards RJ-11 jack labeled RS-485 Bridge connects to the device s control bridge, which electrically isolates RS-485 buses connected to it for more reliable communication; also connected to T-bus Three-stage Protection First stage: gas tubes Second and third stages: inductors and TVS diodes (power) or resistors and TVS diodes (communication) DC Protection Complies with the applicable standards stated in the IEC class 4 standard for DC power lines Maximum working voltage: 8 V Test results available for the following test conditions: surge voltages ±0.5kV, 1kV, kv and 4kV; common mode (input to ground); differential mode (input to input); 8x0µs waveform; ohm generator impedance; 1-minute pause between surges RS-485 Protection Complies with the applicable standards stated in the IEC class 4 standard for communication lines Maximum working voltage: 5 V Test results available for the following test conditions: surge voltages ±0.5kV, 1kV, kv and 4kV; common mode (input to ground); differential mode (input to input); 8x0µs waveform; 1 ohm generator impedance; 1-minute pause between surges Passes manufacturer s test before shipping Extended Support Extended support options are available from Wavetronix; contact a Wavetronix representative for more information

4 T-bus Connector Specifications Dimensions: 1.4 in. x 1. in. x 0.7 in. (.5 cm x cm x 1.7 cm) Weight: 0.01 lbs. (4.5 g) Comes in two models: green for data and power, gray for power only Nominal current : 8 Nominal voltage UN: 150 V Passed manufacturer s mechanical, electrical and material tests End Bracket Specifications Weight: 0.01 lbs. (6. g) dimensions: 0.7 in. x. in. x 1.6 in. (0.9 cm x 5.5 cm x 4 cm) Passed manufacturer s mechanical and material tests SC to Plug SC 10 WG Terminal Blocks Specifications dimensions: with plug 0.5 in. x. in. x.4 in. (0.6 cm x 5.5 cm x 6 cm); without plug 0.5 in. x. in. x 1.4 in. (0.6 cm x 5.5 cm x.6 cm) Insulating material: P Insulating material group: I Flammability: UL 94 V0 Number of connections: Pollution degree: mbient operating temperature: -67 F to 1 F (-55 C to 100 C) Plug connector comes in left, middle and right models for correct assembly Matching end cover protects exposed conductor Nominal current : Nominal voltage UN: 800 V Maximum load current: Terminal block base connect: spring cage Terminal block plug connect: spring cage Removable plug Wire: 8 10 WG Stripping length: /8 in. (0.95 cm) Internal cylindrical gage: Color Coding Comes in three different models: gray (standard); green (earth ground); and blue (used to color-code plugs to ensure correct placement) Ground Green block is grounded via metal foot to D rail Rated surge voltage: 6 kv Surge voltage category: III Connection in acc. with standard: IEC Passed manufacturer s mechanical, electrical and material tests IDC to Plug IDC Terminal Blocks Specifications dimensions: with plug: 0. in. x.1 in. x.6 in. (0.5 cm x 5. cm x 6.6 cm); without plug 0. in. x.1 in. x 1.45 in. (0.5 cm x 5. cm x.7 cm) Insulating material: P Insulating material group: I Flammability: UL 94 V0 Pollution degree: mbient operating temperature: -67 F to 1 F (-55 C to 100 C) Plug connector comes in left, middle and right models for correct assembly Matching end cover protects exposed conductor Nominal current : 17.5 Nominal voltage UN: 500 V Maximum load current: 17.5 Number of connections: 4

5 Terminal block base connect: insulation displacement Terminal block plug connect: insulation displacement Removable plug Wire: 4 16 WG Color Coding Comes in three different models: gray (standard); green (earth ground); and blue (used to color-code plugs to ensure correct placement) Ground Green block is grounded via metal foot to D rail Rated surge voltage: 6 kv Surge voltage category: III Connection in acc. with standard: IEC Passed manufacturer s mechanical, electrical and material tests Traffic Cabinet Back Plate Specifications Material: aluminum Thickness: 0.08 in. (0. cm) dimensions: 11 in. x 11.5 in (7.9 cm x 9. cm) Number of D rails: The advertised detection accuracy of the company s sensors is based on both external and internal testing, as outlined in each product s specification document. lthough our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s). 5

6 Intersection Preassembled Backplate DC Bid Specification 1.0 General. This item shall govern the purchase of a preassembled backplate (PB) equivalent to the Wavetronix intersection preassembled backplate, as part of a system involving a radar presence detector (RPD) system or a continuous tracker advance detector (CTD) system..0 Product Description. The PB shall be a preassembled traffic cabinet backplate that includes the following elements (where multiple models of the same device are listed, their use depends on whether the PB is meant to support two or four sensors): or 5 circuit breakers equivalent to the Click 10-0/10-08; a DC surge suppresion device equivalent to the Click 1; 1 or system surge protection devices equivalent to the Click ; T-bus connectors; terminal blocks for sensor cable termination; terminal blocks for DC line input; end blocks for stabilization and spacing; a traffic cabinet backplate as a mounting platform; and necessary cables, including a power cord, ground cable, and patch cables. 6

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

Intersection Segmented Backplate

Intersection Segmented Backplate Intersection Segmented Backplate The intersection segmented backplate comes prewired with all the devices you need to support a twoor foursensor SmartSensor Advance or Matri installation, but instead of

More information

Click Desktop Kit. Click Desktop Kit

Click Desktop Kit. Click Desktop Kit Click Desktop Kit Click Desktop Kit The Click Desktop Kit is a desktop-mounted set that gives you the building blocks necessary to work with your Click modules at your computer, whether you re testing

More information

Cabinet Interface Device

Cabinet Interface Device Cabinet Interface Device Click 650 The Click 650 provides streamlined communication for SmartSensor Matrix and Advance to traffic controllers in one compact case. This module communicates directly to the

More information

Click! 301. Serial to Ethernet Converter

Click! 301. Serial to Ethernet Converter Serial to Ethernet Converter The Click! 301 converts half-duplex RS-232 & RS-485 communication to Ethernet and vice versa. This device, tested to work over a 34 C to 74 C temperature range, can be used

More information

Bluetooth to Serial Converter TOP FRONT. Click 421

Bluetooth to Serial Converter TOP FRONT. Click 421 Bluetooth to Serial Converter Click 421 The Click 421 converts half-duplex serial communications to Bluetooth and vice versa. The convenience of Bluetooth communication allows users to monitor sensors

More information

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

900 MHz Spread Spectrum Radio TOP FRONT. Click 400 900 MHz Spread Spectrum Radio Click 400 The Click 400 is a 900 MHz spread spectrum radio with two RS-485 ports and one RS-232 port which are active at all times. The Click 400 auto-detects the serial settings

More information

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342 Managed 100 Mbps Ethernet Switches Click 340/341/342 The Click 340/341/342 are compact managed Ethernet switches that add network configuration capability, remote monitoring and diagnostics, and integral

More information

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification.

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification. Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification. This device is installed in an IT chassis and works in conjunction

More information

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors

More information

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/ Surgelogic Surge Protective Devices (SPDs) Residential Catalog 6671CT9701R08/12 2012 CONTENTS Whole House Surge Protective Devices (SPDs).................... 3 SDSB1175C / SDSB1175CB Whole House SPDs..................4

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

PIT 2,5-TWIN. Extract from the online catalog. Order No.:

PIT 2,5-TWIN. Extract from the online catalog. Order No.: Extract from the online catalog PIT 2,5-TWIN Order No.: 3209549 Feed-through modular terminal block, Type of connection: Leg spring connection, Leg spring connection, Cross section: - 4 mm², AWG 26-12,

More information

Click 65x Series USER GUIDE

Click 65x Series USER GUIDE Click 65x Series USER GUIDE Click 65x Series USER GUIDE www.wavetronix.com 78 East 1700 South Provo, Utah 84606 801.734.7200 2017 Wavetronix LLC. All Rights Reserved. Wavetronix, SmartSensor, Click, Command,

More information

UK 5 N BU. Extract from the online catalog. Order No.:

UK 5 N BU. Extract from the online catalog. Order No.: Extract from the online catalog UK 5 N BU Order No.: 3004388 Feed-through modular terminal block, Type of connection: Screw connection, Cross section: 0.2 mm² - 6 mm², AWG 24-10, Width: 6.2 mm, Color:

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

RCMB20/RCMB Series

RCMB20/RCMB Series 4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012 BENDER Inc. 700 Fox Chase, Coatesville

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

8WH5 Combination Plug-In Terminals

8WH5 Combination Plug-In Terminals 8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical

More information

Photoelectric Sensor

Photoelectric Sensor Sensing Supply Voltage Output 3m 1.cm,2m 10cm 2 to 20 VAC, 0/60 Hz to200ma, 20 VAC 100 ma, 2 VDC Photoelectric Sensor Threaded Cylindrical M1 Size Sensors with Built-in Amplifier Chemical resistant, ABS

More information

PIT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

PIT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.: Extract from the online catalog PIT 2,5-QUATTRO-PE Order No.: 3209594 Ground modular terminal block, Type of connection: Leg spring connection, Leg spring connection, Cross section: - 4 mm², AWG 26-12,

More information

PIT 2,5-TWIN-DIO/R-L. Extract from the online catalog. Order No.:

PIT 2,5-TWIN-DIO/R-L. Extract from the online catalog. Order No.: Extract from the online catalog PIT 2,5-TWIN-DIO/R-L Order No.: 3210253 Feed-through modular terminal block, Type of connection: Leg spring connection, Leg spring connection, Number of positions: 1, Cross

More information

SER-4485-SI-M USER S MANUAL

SER-4485-SI-M USER S MANUAL SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

UDK 4. Extract from the online catalog. Order No.:

UDK 4. Extract from the online catalog. Order No.: Extract from the online catalog UDK 4 Order No.: 2775016 1-level terminal block with double connection on both sides, cross section: 0.2-2.5 mm², AWG: 30-10, width: 6.2 mm, color: Gray Commercial data

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

UK 6 N. Extract from the online catalog. Order No.:

UK 6 N. Extract from the online catalog. Order No.: Extract from the online catalog UK 6 N Order No.: 3004524 Feed-through modular terminal block, Type of connection: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG 24-8, Width: 8.2 mm, Color: gray,

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface

More information

PLC-RSC- 24DC/21 Order No.:

PLC-RSC- 24DC/21 Order No.: Typical release time Operating voltage display Name of protection Protective circuit/component 8 ms Yes Polarity protection Polarity protection diode Contact side Contact type Contact material Maximum

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

SURGE PROTECTION OPTION

SURGE PROTECTION OPTION Reliable Continuous Energy PV FOR TELECOM Installation Guide Gen 4 PVT Panels ENHANCED SURGE PROTECTION OPTION Manual Rev 4.4 Apollo Solar -- Gen 4 PVT Enhanced Surge Protection Option Page - 1 - IMPORTANT

More information

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series Applications Pan-Tilt-Zoom (PTZ) analog video cameras Features Individual protection circuits for analog video

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Controlesta RCO-Compact

Controlesta RCO-Compact Commissioning NOTICE The details contained in these documents and data can be changed without prior advance notice No part of these documents may be reproduced or passed on without the specific written

More information

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof

More information

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.: Extract from the online catalog PLC-RSC- 24UC/21 Order No.: 2966184 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Product availability : Stock - Normally stocked in distribution facility Price* : 494.00 USD Main Range of product

More information

UK 5-TWIN. Extract from the online catalog. Order No.:

UK 5-TWIN. Extract from the online catalog. Order No.: Extract from the online catalog UK 5-TWIN Order No.: 1923021 1-level terminal block with double connection on one side, cross section: 0.2 -, AWG: 24-12, width: 6.2 mm, color: gray Commercial data EAN

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

UT 2,5-PE. Extract from the online catalog. Order No.:

UT 2,5-PE. Extract from the online catalog. Order No.: Extract from the online catalog UT 2,5-PE Order No.: 3044092 Feed-through modular terminal block, Type of connection: Screw connection, Screw connection, Cross section: - 4 mm², AWG 26-12, Width: 5.2 mm,

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete

More information

DIK 1,5. Extract from the online catalog. Order No.:

DIK 1,5. Extract from the online catalog. Order No.: Extract from the online catalog DIK 1,5 Order No.: 2715966 Three-level initiator terminal block, cross section: 0.2-2.5 mm², AWG: 30-14, width: 6.2 mm, color: gray Commercial data EAN 4017918061715 Pack

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

em4 Accessories Digital expansions

em4 Accessories Digital expansions em4 Accessories Digital expansions Up to two digital / analog expansions can be added to the em4 nanoplc to expand up to 46 I/Os 6 digital / analog configurable inputs (0-10 VDC, 0-28.8 VDC, Potentiometer)

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

MONITORING INTELLIRACK USER MANUAL

MONITORING INTELLIRACK USER MANUAL MONITORING INTELLIRACK USER MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION..........................................................1 1.1 Overview...................................................................

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.: Extract from the online catalog PLC-RSC- 24DC/21 Order No.: 2966171 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and

More information

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO Description: The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while providing a simple interface between a CANopen network and other electronic devices on a machine. The

More information

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description PLC-R 2HC PLC INERFCE With SPD Relay, High-Current Version INERFCE Data Sheet 022_03_en PHOENIX CONC - 02/08 Description number of applications such as electrical heating systems require higher continuous

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

4-Port USB 3.0 Rugged Industrial Din Rail Mount Hub

4-Port USB 3.0 Rugged Industrial Din Rail Mount Hub 4-Port USB 3.0 Rugged Industrial Din Rail Mount Hub Gearmo Version 1.0 March 2018 Model # GM-HU34 Product Manual 2 PRODUCT MANUAL GM-HU34 REVISION HISTORY Revision Date Author Comments 1.0 03/16/2018 Gearmo

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

ST 2,5. Extract from the online catalog. Order No.:

ST 2,5. Extract from the online catalog. Order No.: Extract from the online catalog ST 2,5 Order No.: 3031212 Feed-through modular terminal block, Type of connection: Springcage connection, Spring-cage connection, Cross section: 0.08 mm² - 4 mm², AWG 28-12,

More information

Power supply unit Model: PAC-SC51KUA

Power supply unit Model: PAC-SC51KUA Air-Conditioner Control System Power supply Model: PAC-SC51KUA Installation Manual Contents 1. Safety Precautions...1 2. Product features...2 1. Specifications...2 2. Power supply capacity...2 3. External

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

PIT 2,5-PE/L/N. Extract from the online catalog. Order No.:

PIT 2,5-PE/L/N. Extract from the online catalog. Order No.: Extract from the online catalog PIT 2,5-PE/L/N Order No.: 3210538 Ground modular terminal block, Type of connection: Leg spring connection, Leg spring connection, Cross section: - 4 mm², AWG 26-12, Width:

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j. User manual ADA-4010 RS-485 / RS-422 to RS-232 Converter Copyright 2001-2017 CEL-MAR spj 1 io_ada-4010_v322_en Contents 1 GENERAL INFORMATION 3 11 WARRANTED INFORMATION 3 12 GENERAL CONDITIONS FOR SAFE

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to

More information

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System

SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)

More information

UK 10-DREHSI (6,3X32)

UK 10-DREHSI (6,3X32) Extract from the online catalog UK 10-DREHSI (6,3X32) Order No.: 3005507 The illustration shows version UK 10-DREHSI (5x20) Fuse terminal block for cartridge fuse insert, cross section: 0.5-16 mm², AWG:

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

Media Converters. Media Converters. Product Selection Guides

Media Converters. Media Converters. Product Selection Guides Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

PLC-OSC-120UC/ 24DC/ 2

PLC-OSC-120UC/ 24DC/ 2 Extract from the online catalog PLC-OSC-120UC/ 24DC/ 2 Order No.: 2966650 The illustration shows the version PLC-BSC- 24DC/21 PLC interface, consisting of base terminal block PLC-BSC with screw connection

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

PT 1,5/S-TWIN. Extract from the online catalog. Order No.:

PT 1,5/S-TWIN. Extract from the online catalog. Order No.: Extract from the online catalog PT 1,5/S-TWIN Order No.: 3208155 Feed-through modular terminal block, Connection method: Pushin connection, Cross section: - 1.5 mm², AWG 26-14, Width: 3.5 mm, Color: gray,

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 38W 5-7mA flexc lp ACED series Product description Built-in constant current ED Driver Adjustable output current between 5 and 7 ma Max. output power 38 W Up to 85 % efficiency ominal life-time

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Digital input module DI4/DI8/DI16 Priva Blue ID Digital input module Modular design An Priva Blue ID DI4 Digital input module, Priva Blue ID DI8 Digital input module or Priva Blue ID DI16 Digital input module are used to take status and

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital

More information