EVOline Frame Dock
|
|
- Isabel Moore
- 5 years ago
- Views:
Transcription
1 Frame Dock 151
2 Supply EVOline U-Dock Examples of supply for circuit 1 and 2 (IT circuit Red) Through the end cap LEFT and / or end cap RIGHT End cap to individually use with cable and end splices. End cap with cable and plug. Variants available. End cap with two cables and plugs. Variants available. End cap with cable and connectors. 152
3 Frame Dock The Frame Dock offers a lot of new options: Not only the nearly unlimited variants of combination out of our large module collection, also the multitude of application make the Frame Dock to an universal problem solver. In case of power and data: Power out of the end cap, data out of the bottom of the profile. U-Dock Individual Just choose the and the configuration! With the modular design of U-Dock you have the opportunity to customise your model the way you wish. End cap with plug connectors GST 18/3-plug, power input How to order Page Screw cover Surface variations End cap with WAGO Winsta plug power input. other surface variations on request. Silver Black Silver Socket Page Data Page Multimedia Page Pushbutton and switch Page Protection Page
4 1 2 3 Frame Dock profile Page 155 Page supply cable Page Empty housing Frame Dock x socket VDE Combination module VGA / Audio USB module Supply cable Desired end cap with or without mounting tabs, Please specify Data module CAT All cable lengths are measured from the connection point and mounting position of the in the profile. Please note for module selection: the profile number determines the permissible combination of and profiles. Profile type No. Dock / R-Dock 1 U-Dock / Frame Dock 2 Port 3 Port Lounge 4 Vertical 5 SubDesk 6 Caddy 7 FlipTop 8 V-Dock 9 154
5 Order example Frame Dock Individual 4 5 Your U-Dock Individual accessories Page Cable- Management to protect your cable distribution Page Ordering information: After receiving your order a product drawing will be sent to you, that you release with your signature, thus avoiding wrong orders. Our general conditions of sale apply for all orders. Subject to technical changes. The goods are not marked with EAN-codes. If required, please order separately. 155
6 Frame Dock Article Picture Specification Type Frame Dock SMALL three sockets, 60, 16 A, Power inlet in the back of the profile Frame Dock DATA SMALL three sockets, 60, 16 A, two modular couplings for patch cable RJ45 to RJ45, 1:1 interconnected CAT6 shielded. Power and data inlet in the back of the profile Frame Dock MEDIUM four sockets, 60, 16 A, Power inlet in the back of the profile Frame Dock MEDIUM four sockets, 60, 16 A, two modular couplings for patch cable RJ45 to RJ45, 1:1 interconnected CAT6 shielded. Power and data inlet in the back of the profile ) Appropriate socket types for international requirements can be found on page
7 Frame Dock Individual Article Picture Specification Type Just combine the in the basic profile of your choice! Thanks to the modular design of the U-Dock, you have the option to compile an individual model according to your wishes. More information about How to order See pages Empty housing Frame Dock ) Appropriate socket types for international requirements can be found on page
The principle. Timeless design in solid Stainless Steel. International modules power, data and multimedia,
FlipTop 159 The principle. Timeless design in solid Stainless Steel. International power, data and multimedia, freely customisable. Connection opening alternative as a brush against dust or as a rubber
More informationThe principle. Timeless design in solid Stainless Steel. International modules power, data and multimedia,
1 156 FlipTop 157 The principle. Timeless design in solid Stainless Steel. International power, data and multimedia, freely customisable. Connection opening alternative as a brush against dust or as a
More informationSupply EVOline Dock. Examples of supply modules for circuit 1 and 2 (IT circuit Red)
1 120 EVOline Dock 121 Supply EVOline Dock Examples of supply modules for circuit 1 and 2 (IT circuit Red) Through the end cap LEFT and / or end cap RIGHT, and out through the bottom of the profile. Anschluss
More informationNightlight Blue Nightlight Red Nightlight Green Nightlight White
Caddy 91 Mobile application of established technology. Rollable housing made of Aluminium. Integrated Port. Cover made of Stainless Steel or in Silver colour. Connections selectable in. Power and multimedia.
More informationEVOline Dock sits above desk surface allowing maximum workspace. It s supported either by
EVOline Dock 57 EVOline Dock EVOline Dock sits above desk surface allowing maximum workspace. It s supported either by hotel rooms, equipped with international electrical sockets, and various multimedia,
More informationEVOline Catalogue 2017
Catalogue 2017 Systems 35 71 Port Push FlipTop Push V-Port 43 75 Dock Square FrameDock T-Dock 49 79 Plug Dock Vertical Square80 57 83 R-Dock Decentralised Electrical Distribution Port 63 U-Dock BackFlip
More informationUtilizing NuVo s Paging & Doorbell Mute Capabilities
Utilizing NuVo s Paging & Doorbell Mute Capabilities One of the great benefits of multi-room audio systems is their ability to surround the home with music in every room. However when listening to your
More informationmodlink msdd Front panel interfaces
Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents
More informationINTERCONNECT SOLUTIONS
INTERCONNECT SOLUTIONS Products Overview Connect with Us... Experience Makes the Difference Who We Are We have been designing and manufacturing interconnect products for over 40 years. Today we supply
More informationonlinecomponents.com
Power entry modules without line filter Felcom 64 IEC Appliance Inlet C14 with modular extended Components Plug removal necessary for fuse replacement 6421.005X.XX Appliance inlet Appliance outlet Snap-In
More informationODU-MAC A PERFECT ALLIANCE. MANUAL MATING AUTOMATIC DOCKING SHORT OVERVIEW
A PERFECT ALLIANCE. ODU-MAC A new performance class. Up to 2,00 V, 2 bar, 0 Gbit/s, > 0,000 mating cycles and 4.0 GHz. MANUAL MATING AUTOMATIC DOCKING SHORT OVERVIEW ODU-MAC BLUE-LINE ODU-MAC SILVER-LINE
More informationODU-MAC A PERFECT ALLIANCE. MANUAL MATING AUTOMATIC DOCKING SHORT OVERVIEW
A PERFECT ALLIANCE. ODU-MAC A new performance class. Up to 2,00 V, 2 bar, 0 Gbit/s, > 0,000 mating cycles and 4.0 GHz. MANUAL MATING AUTOMATIC DOCKING SHORT OVERVIEW ODU-MAC BLUE-LINE ODU-MAC SILVER-LINE
More informationWasher Allegro AC XB RGB
Date: Quantity: Company: Project: Washer Allegro AC XB RGB The Washer Allegro AC XB RGB is a compact, AC line powered high brightness luminaire. The fixture is controllable via DMX512, and features 16.7
More informationDATA TECHNOLOGY & MULTIMEDIA
DATA TECHNOLOGY & MULTIMEDIA... all over IP! Everything for... Office-, Home cabling & Multimedia. IK DATENTECHN MULTIMEDIA Compact solutions (office-cabling) Quality products Overview compact components
More informationInnovative system solutions flexible connection technology
426 Innovative system solutions flexible connection technology Systems for direct Ethernet device connection 1 Direct PC Board Connection 433 2 IP67 Protected Connectors Variant 1 436 3 IP67 Protected
More informationWIDE RANGE OF SOLUTIONS
network solutions WIDE RANGE OF SOLUTIONS 19 wall mounted racks with 6, 8, 13 and 17U and floor mounted with 24U 10 wall mounted Racks 6U Available in white (RAL 9010), grey (RAL 703) and black (RAL 900)
More information* SATA cable and SATA power cable are included in the HDVR. Contents. Hard Disk Installation. Hardware Connection. Caution
Contents Hard Disk Installation Caution Step 3: Please align the screw holes on the HDD with those on the HDVR case and secure them with the given screws. Hardware Connection Before installing the HDD,
More informationUSB Type-C TM Connector DX07 Series Vertical Plug
COMPONENTS PRODUCT INFORMATION NEW USB Type-C TM Connector DX07 Series Vertical Plug CONNECTOR MB-0332-1 July 2018 RoHS Compliant *Plug will be packaged with protective cap on. Protective Cap The DX07
More informationInterfaces Service and Field
Interfaces Service and Field Front Panel Interfaces Interfaces Service Receptacles Cable Entry Systems 02 TRANSFORMATOREN 03 MODLINK MSDD THE CONNECTION TO THE OUTSIDE WORLD A safe bet MARKET REQUIREMENTS
More informationDF-60 Rotary Electric Encoder
Absolute Position Encoder options Copyright 2013 Netzer Precision Motion Sensors LTD, All rights reserved. Page 1 of 16 JUNE 2016 options 1.1 Table of 1. 3 1.1 Version : 1.0 April 2016 3 1.2 Applicable
More informationhotels 2016/2017 It's electric. English
hotels 06/07 It's electric. English Our goal here at BACHMANN is to be a trendsetter and to bring innovations to life. We want to improve quality of life with our solutions people should feel at ease
More informationEUBIQ GSS POWER TRACK. (GROUNDED SENTRY SHUTTER) system free yourself from fixed power outlets. RH2 Recess Power & Data Housing
GSS POWER TRACK (GROUNDED SENTRY SHUTTER) system free yourself from fixed power outlets OUTLETS ANYWHERE, ANYTIME! SFC2s Modular Track Common to SH1, VSF, RH & DMS Housings 62 Stock lengths Product Code
More informationTeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox
1/8 FEATURES Connectivity via landline and PC/VoiP for tele- and web conferencing One solution with high flexibility for end-users Easy to use with ios app or any network device via web server application
More informationCONTENTS. Introduction Characteristics Product range. Pages
R2CT TM Series R2CT CONTENTS R2CT TM Pages Introduction... 9-4 Characteristics...9-5 Product range R2CT TM standard plug kit...9-6 R2CT TM mini short plug kit... 9-7 R2CT TM standard receptacle...9-8 R2CT
More informationWINSTA Modern Installations Are Pluggable
WINSTA Modern Installations Are Pluggable MODERN BUILDING REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Building use should be flexible and expandable. Reduction in construction times Shortage of skilled labor
More informationHAWK MV-4000 Smart Camera
HAWK MV-4000 Smart Camera Configuration Guide Hardware Required Item Description Part Number HAWK MV-4000 Smart Camera 8XX-XXX0-00X Lens, C-Mount 98-9000XX-0 3 IP67 Lens Cover for HAWK MV-4000, 50 mm or
More informationDebug Tool Fashion Accessories An showcase of development tool accessories designed to enhance your debug session
Debug Tool Fashion Accessories An showcase of development tool accessories designed to enhance your debug session July 2012 This webinar takes a look at some of the available debug and emulation tool accessories
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationPower and data close at hand with the Deskbox from OBO
Power and data close at hand with the from OBO System information The DB Desbox beautifully flexible High-quality, a slim design and a variety of installation options. The DB can be positioned flexibly
More informationKVM Add-On RackConsoles
RackConsoles 17 7.2 Value adding solutions for your KVM an IT applications Leading the way in digital KVM The company Leading the Way in digital KVM Guntermann & Drunck GmbH has been established in 1985
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationShield AC Extend XB RGB
Date: Quantity: Company: Project: The Traxon is a modular high-brightness lighting system with adjustable multi-led heads. The AC powered system is IP66-rated, and can be daisy-chained to form larger multi-beam
More informationContents Built-in power strips... 4 On-desk power strips Recessed power strips Mobile solutions Configuration variants...
Electrification 1 Contents 1 Built-in power strips... 4 1.1 EVOline FlipTop Push...4 1.2 NETBOX Turn Comfort...6 1.3 TOP FRAME...8 1.4 EVOline BackFlip...10 1.5 EVOline FrameDock...12 1.6 EVOline Square80...14
More informationDC Connector. Data sheet LINAK.COM/HOMELINE
DC Connector Data sheet LINAK.COM/HOMELINE DC Connector The DC CONNECTOR is a HOMELINE accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE TD3
More informationENGLISH / 2016 KITCHEN SOLUTIONS. Modern integration of power for kitchens. It's electric.
ENGLISH / 2016 KITCHEN SOLUTIONS Modern integration of power for kitchens It's electric. KITCHEN SOLUTIONS Contents Plug into a world of opportunities The new BACHMANN power strips for kitchens are the
More information3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing
3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector
More information4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT
Components for TV/SAT, telephone installations and Category 5 DATATEL - TEL DATATEL - CAT5 DATATEL - TV/SAT 7 7 Components for telephone installations FIXED TELEPHONE SOCKETS Type RJ Socket 6/ surface
More informationNVR CH Network Video Recorder. Quick Installation Guide v1.0
NVR-0104 4-CH Network Video Recorder Quick Installation Guide v1.0 2 NVR-0104 Quick Installation Guide Package Contents NVR-0104 Network Video Recorder IR Remote controller RJ-45 Ethernet LAN cable Power
More informationLiner Shield AC XB CW
The is an IP66- rated, AC line input, linear lighting fixture equipped with 18, 27, or 36 high brightness LEDs, dedicated to project an intense even light spread to brightly wash any flat surface with
More informationSignature 384 Upsampler and USB input Users Manual
Signature 384 Upsampler and USB input Users Manual Rev 1 (4/09) Signature 384 Upsampler Installation Procedure: 1) Remove one Side Panel (End Cap) by removing 4 Allen Screws as shown. 2) Remove 6 Philips
More informationCNK600 Cable-Nook Interconnect Box
CNK600 Cable-Nook Interconnect Box Welcome! We greatly appreciate your purchase of the CNK600 Cable-Nook Interconnect Box. We are sure you will find it reliable and simple to use. Superior performance
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationLiner Shield AC XB RGB
The Liner Shield AC XB is an IP66- rated, AC line input, linear lighting fixture equipped with 18, 27, or 36 high brightness LEDs, dedicated to project an intense even light spread to brightly color wash
More informationEthernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.
Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile
More informationThe Motion C5/F5 Docking Station provides a. Simple, smooth design for ease of cleaning; use; 38 - pen use.
Motion Computing Accessories and Options Motion Computing LE-1700 Motion Computing F5 Options The Motion FlexDock provides a docking/workstation environment for the LE series Tablet PC; Provides 3x USB,
More informationREMOTE HEAD ADAPTER INSTALLATION GUIDE
REMOTE HEAD ADAPTER INSTALLATION GUIDE The Remote Head adapter is a valuable accessory for the Uniden BC-780, 785 and 796 scanners. It allows the scanner's control panel to be removed from the radio and
More informationInstallation Guide. Retrofit Kit for USB Ready Intraoral Systems
Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the
More informationhotels 2016/2017 It's electric. English
hotels 2016/2017 It's electric. English Our goal here at BACHMANN is to be a trendsetter and to bring innovations to life. We want to improve quality of life with our solutions people should feel at ease
More informationORDERING INFORMATION: P/N K W P 8 8 F M M 1 WATERPROOF RJ45 JACK TO PLUG CABLE ASSEMBLIES W207
WATERPROOF RJ45 JACK TO PLUG CABLE ASSEMBLIES MATERIALS Plastic Housing: Engineering Thermoplastic Flammbility Rating UL 94V-0 Contacts: Phosphor Bronze Plating: Gold Plating over Nickel in Contact Nut:
More informationInstallation Manual. Ultegra Junior Bench Scale. USB Interface by Fairbanks Scales, Inc All rights reserved Revision 4 07/13
Installation Manual Ultegra Junior Bench Scale USB Interface 2011-2013 by Fairbanks Scales, Inc. 51119 All rights reserved Revision 4 07/13 Amendment Record Ultegra Junior Bench Scale USB Interface Document
More informationPV Grid Connected. PRIce LIST valid from 1st Januar 2014 by Steca
PV Grid Connected PRIce LIST 2014-1 valid from 1st Januar 2014 by Steca qüééçáíçêá~äëí~ññçñmelqlkfåíéêå~íáçå~äóqüépçä~êmçïéêj~ö~òáåé qüééçáíçêá~äëí~ññçñmelqlkfåíéêå~íáçå~äóqüépçä~êmçïéêj~ö~òáåé ÜÉêÉÄóÅÉêíáÑáÉëíÜ~ííÜÉáåîÉêíÉê
More informationADN PS. Power Supply. Instruction manual
Power Supply Instruction manual Contents Contents For your safety... The power supply... 2 Package contents... 2 Components required for operation... 3 Product overview power supply... 4 Structuring and
More informationSignal Extender USB Extender 7.0. Signal Extender Extender systems to bridge IT-distances
Signal Extender USB Extender Extender systems to bridge IT-distances The company Leading the Way in digital KVM Guntermann & Drunck GmbH has been established in 1985 and is named after its founders. Over
More informationUTS UTS. UTS provides a connection that performs faster, easier, safer and more reliable, it makes :
Company Profile UTS Contents Company profile... 2 Contents... 3 Description... 3 Overview TRIM TRIO... 4 Major features & benefits 5-9 Contact styles... 5 Rapid and secure locking system... 6 Rapid and
More information* ) Article No.: Article No.: MCS IV plus. Contents. Device descripition... 2 Technical Data... 2 Dimensions... 3 Accessories...
Coin device MCS IV plus * ) The circuit board performance MCS is the interface between the hand-held remote control and the professional sunbed devices from Ergoline without inherent electronics (Ergoline
More informationFL SWITCH SFN 5TX. Extract from the online catalog. Order No.:
Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial
More informationODU-MAC A PERFECT ALLIANCE. AUTOMATIC DOCKING MANUAL MATING SHORT OVERVIEW
A PERFECT ALLIANCE. ODU-MAC Compact modular connector system. Up to,00 V, 0 bar, 0 Gbit/s, 00,000 mating cycles and 9.0 GHz. AUTOMATIC DOCKING MANUAL MATING SHORT OVERVIEW ODU-MAC SILVER-LINE ODU-MAC WHITE-LINE
More informationStandard Configuration - 4) 15 amp power receptacles 1) Cutout for configurable telecom plates. Door Finishes - UL Listed
power modules P-1 conference table power info List Price - PM-P-1-B - $415 Black Laminate Tech Doors PM-P-1-A - $665 Brushed Tech Doors PM-P-1-SS - $685 Solid Surface Tech Doors P-1 Power Module Power
More information[.050 (1.27mm) Density. D-Microminiature]
Commercial [.050 (1.27mm) Density Solder Introduction Cup/Wire D-Microminiature] Cinch Commercial Products, consisting of Jones Plugs and Sockets, Barrier Blocks, Edge Cards, Two-Piece Commercial Dins,
More informationQUICK START GUIDE. STEP X - Name of Step DTX1000-T, DTX1000-R, DTX1002-T, DTX1002-R INVISAPC DTX1000/2
STEP X - Name of Step QUICK START GUIDE DTX1000-T, DTX1000-R, DTX1002-T, DTX1002-R INVISAPC DTX1000/2 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1A - DTX1000-T Option Transmitter
More informationCables and Connectors FDD / HDD cable
Cables and Connectors FDD / HDD cable SATA HDD cable Model Name 32801-000703-400-RS 32102-000100-100-RS 32000-080700-RS Cable type SATA HDD cable SATA power cable SATA + Power cable Connector SATA 7-pin
More informationFLEXCurtain HD. Installation and Start Guide. Connection Guide. Operating Guide. Reference Guide. Your partner for Solutions
Your partner for Solutions FLEXCurtain HD Indoor 3.9mm, 4.8mm, 5.2mm, 6.9mm, 8.9mm, 12.5mm Installation and Start Guide Connection Guide Operating Guide Reference Guide 1 About this document. Please follow
More informationAll in One Multi-purpose Cable Tester and Cable Tracer
All in One Multi-purpose Cable Tester and Cable Tracer INSTRUCTION MANUAL INDEX Multi-purpose Cable Tester PAGE INTRODUCTION... 1 FEATURES... 1 INSTRUMENT LAYOUT... 2 OPERATION Loopback Test... Remote
More informationConnecting igaging DigiMAG Scales to the Caliper2PC Interface A step by step Guide
What is an igaging DigiMAG Scale? The igaging DigiMAG are digital linear scales that are easily connectable to the Caliper2PC interface. They consist of two parts, the encoder and the readout unit. The
More informationODU-MAC A PERFECT ALLIANCE. AUTOMATIC DOCKING MANUAL MATING SHORT OVERVIEW
A PERFECT ALLIANCE. ODU-MAC Compact modular connector system. Up to 6,00 V, 0 bar, 0 Gbit/s, 00,000 mating cycles and 9.0 GHz. AUTOMATIC DOCKING MANUAL MATING SHORT OVERVIEW ODU-MAC SILVER-LINE ODU-MAC
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More informationWasher Quattro AC XB DW
Date: Quantity: Company: Project: Washer Quattro AC XB DW The Washer Quattro AC XB DW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for
More informationDigital Signage DiSign-System 7.2
DiSign-System Extension and distribution of audio and/or video signals Leading the way in digital KVM The company Leading the Way in digital KVM Guntermann & Drunck GmbH has been established in 1985 and
More informationQuickNetwork QND300 Distribution Panel
QuickNetwork QND300 Distribution Panel Installation Guide CSQND300V1 10/04 Rev. A Before You Get Started This manual is designed to provide an overview of the installation process and guidelines for installing
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationWasher Quattro AC XB RGBW
Date: Quantity: Company: Project: Washer Quattro AC XB RGBW The Washer Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing
More informationWINSTA The Connection System. A Complete Range of Connectors
WINSTA The Connection System A Complete Range of Connectors WINSTA Connection System The perfect connection! We all use them on a daily basis: Pluggable connectors. We like their simplicity and know that
More informationHardware Manual RM Display 2501 S01..S04
Hardware Manual RM Display 2501 S01..S04 Table of Contents 1 Legal Regulations...3 2 About the Display 2501...4 3 Important information for using RM Display 2501...5 4 Disposal...5 5 Installation...6 5.1
More informationFLEX MATRIX. Complete Guide to the Intelix Flex Matrix Switcher Series
FLEX MATRIX Complete Guide to the Intelix Flex Matrix Switcher Series FLEX MATRIX // REAL VALUE FOR THE PRO AV INSTALLER Flex some signal distribution muscle with Liberty s full line of Intelix Flex Matrices!
More informationFieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm
Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected
More informationVGA multimedia board
VGA multimedia board www.matrixtsl.com EB071 Contents About this document 3 Board layout 3 General information 4 Circuit description 5 Protective cover 5 Circuit diagram 6 2 Copyright About this document
More informationT0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE
T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length
More informationEcoFlex LED Neon Manual
Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of
More informationUniversal MATE-N-LOK Headers for UMNL II Connectors
for UMNL II Connectors PC Board Vertical Pin Headers [6.5] Centerline spacing,, and 5 Circuit, In-Line Housing Nylon Flammability ating UL9V-0 Contacts Phosphor bronze Solder tail diameter.06 [1.57] elated
More informationCU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:
CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions
More informationAS-i Safety Input Modules (M12), IP67
Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4
More informationWP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments
CPU module for small and medium sized wind turbines Safe operation in harsh environments Maintenance free - no fans and no batteries that need replacement Advanced event based data logging and storage
More informationCAUTION READ CAREFULLY
DOCKING DRAWER INSTALL MANUAL, 0230-00004 Rev 2 7/1/15 Applicable Models: 0290-00030, 0290-00031 JTech Solutions, Inc. 12893 Alcosta Blvd. Ste M San Ramon, CA 94583 www.jtechsolutions.us CAUTION READ CAREFULLY
More informationSelf Sustaining Arduino
Description This document is a tutorial for creating a self sustaining Arduino board, by harnessing solar energy. It would be incorporated with a rechargeable 9V battery. What makes this unique is that
More informationHOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA
HOUSING DEVICES, INC. ADA - ARCU Installation & Operations Manual Made in the USA ADA - ARCU 5 & 10 Pre-Installation Requirements: For each ADA-1000 in the elevator you must run a twisted, shielded, 22
More informationinsilco. intelligent networking. insilco. intelligent networking
insilco intelligent networking 04-07 - 2017 insilco intelligent networking 28-10 - 2016 Contents Intelligent Network Management System 01 Network Scanner 02 Smart Patch Panels 03 Smart Patch Cords, Flat
More informationSIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No
SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95
More informationIt s electric. COMPLETE CATALOGUE 2013 / 2014 Innovative products for the professional user. ENGLISH / 2013/14
ENGLISH / 2013/14 Electrical materials IT power distribution Manufacturing Facility systems COMPLETE CATALOGUE 2013 / 2014 Innovative products for the professional user. It s electric. BACHMANN / Complete
More informationANIxx. Installation Manual.
ANIxx Installation Manual www.audac.eu Introduction WaveDynamics Dante audio network interface The ANIxx are Dante audio network interfaces for use with WaveDynamics supporting amplifiers, supporting two
More informationCables, Cards & Connectors
Malling U3A Computer Group Cables, Cards & Connectors Chris Daly 5 th February 2018 Cables, Cards & Connectors How many of you have a box or drawer of cables? How many of you are unsure which cable or
More informationSHALLOW FLOOR BOXES.
SHALLOW FLOOR BOXES TABLE OF CONTENTS Description Applications References Features Configuration type Installation Technical Data Mechanism compatibility Dimensions Description Floor housings for electrical
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationPOWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION
POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION NCE Corporation 1260 CREEK STREET SUITE 100 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:
More informationHeathkit HR-1680 PC Card Extender. Heathkit HR-1680 PC Assembly Extender Assembly
Heathkit HR-1680 PC Assembly Extender Assembly Version Date Author Comment 1.0 August 15, 2009 RM Groh Original draft Table of Contents Introduction...1 Heathkit s Approach...2 Parts Required...3 Assembly
More informationOctalink 1U Manual. Octalink 1U. Passive 8-Channel Patchbay. Manual Revision:
Octalink 1U Passive 8-Channel Patchbay Manual Revision: 2018.08.03 Installation This module is designed for use within an Intellijel-standard 1U row, such as contained within the Intellijel 4U and 7U Eurorack
More informationBVS UR E Ordering code: BVS001H
BVS UR-3-101-E Ordering code: BVS001H Vision sensor BVS-E Universal PNP (2x) 1) Teach reference image, 2) Power, 3) Output 1 active, 4) Output 2 active, 5) Connection with PC, 6) Sharpness Characteristic
More informationPropeller Proto Board (#32212) Propeller Proto Board USB (#32812) Proto Board Accessory Kit (# )
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationCERTUS Configurable Safety Module
Reduces the number of components (less footprint and wiring) Faster electrical cabinet construction Flexible, intuitive and quick logical configuration software Easy to set up tamper-proof safety systems
More informationAccessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)
25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The
More information