MODELS PD230 AND PD1230 Installation Instructions
|
|
- Christal Todd
- 5 years ago
- Views:
Transcription
1 PNEUMERCATOR Liquid Level Control Systems MODELS PD20 AND PD20 Installation Instructions Model PD20 x2 Channel Lightning Surge Protector Model PD20 x2 Channel Lightning Surge Protector COPYRIGHT 2007 PNEUMERCATOR CO., INC. TEL: (6) FAX: (6) WEBSITE: PNEUMERCATOR TECHNICAL SUPPORT (800) Bulletin 66 Rev. A (2/20/07) Page of 8 4/2/20 5:4:6 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
2 PD20 - x2 CHANNEL LIGHTNING SURGE PROTECTOR: Model PD20 provides protection for up to (6) circuits when (2) PM05 or PM24 modules are installed. PD20s are generally installed as close as practical to probes and/or sensors. PD20 - x2 CHANNEL LIGHTNING SURGE PROTECTOR: Model PD20 provides protection for up to (6) circuits when (2) PM05 or PM24 modules are installed. PD20s are generally installed as close as practical to a tank monitoring console such as Pneumercator E, LDE or TMS series. PM05 OR PM24 - LIGHTNING SURGE PROTECTOR MODULE: Each module consists of () independent circuits. The modules are polarized and must be installed as shown on page 8. Modules are sold () per pack separately from the PD20 and PD20 consoles, see table below. ENLARGED FOR CLARITY PM24 MODULE SHOWN MODULE PM05- (-PACK) PM24- (-PACK) DESCRIPTION 5V SURGE PROTECTOR MODULE 24V SURGE PROTECTOR MODULE TANK MONITORING CONSOLE PNEUMERCATOR E OR LDE SERIES PNEUMERCATOR TMS SERIES Bulletin 66 Rev. A (2/20/07) Page 2 of 8 4/2/20 5:4:6 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
3 GENERAL OVERVIEW EXAMPLE TANK MONITORING CONSOLE (TMS SERIES SHOWN) PD20! WARNING Refer to TMS installation manual for WARNINGS and CAUTIONS before proceeding. FAILURE TO COMPLY MAY RESULT IN PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. TYPICAL PNEUMERCATOR PROBE MODELS 2-WIRE -WIRE * MP46SC MP450S MP46SV MP462SV MP46SV TYPICAL PNEUMERCATOR SENSOR MODELS 2-WIRE -WIRE HS00-ND ES SERIES LS600 ES SERIES LS600LD SERIES LS60 HS00D RSU80 RSU800 (NON-DISCRIMINATING) MP45S MP452S * () CONDUCTOR IS PROBE GROUND WIRE. SEE WIRING ON PAGE 6. RSU800 (DISCRIMINATING) TO EARTH GROUND PD20 TYPICAL TANK W/ PROBE PD20 PD20 PD20 TYPICAL TANK W/ PROBE AND (2) 2-WIRE SENSORS TYPICAL TANK W/ PROBE AND -WIRE SENSOR (2) -WIRE SENSORS Bulletin 66 Rev. A (2/20/07) Page of 8 4/2/20 5:4:7 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
4 PD20 ENCLOSURE OUTLINE DRAWING SECTION A-A 5 6 [00] SQ. A 25 2 [20] 6 [8] OVERALL HEIGHT ALIGNMENT PIN [66] (4) MOUNTING HOLES Ø 8 7 [Ø22] THRU BOTH SIDES FOR /2" NPT WATERTIGHT FITTINGS OR METRIC EQUIVALENTS A LID/COVER SHOWN FOR REF. 8 [86] GASKET NOTES:. ENCLOSURE RATING: UP TO NEMA 4X; IP 66, DIN DIMENSIONS: INCHES [MM].. DRAWING SCALE: / [9] [62] COVER INSTALLATION COVER LABEL GASKET IMPORTANT! IF YOUR ENCLOSURE DOES NOT HAVE AN ALIGNMENT PIN AND/OR LABELS INSTALLED, ALIGN THE GASKET SHORT AND LONG SIDES AS SHOWN TO CREATE A WATERTIGHT SEAL WHEN THE COVER IS SECU. WALL MOUNT EXAMPLE SCREW ANCHOR 2 [9] LONG SIDE SHORT SIDE ALIGNMENT PIN (SEE NOTE ABOVE) (4) MOUNTING SCREWS USE #6 X /4" LENGTH MOUNTING SCREWS (7/64" [6.75 MM] MAX. SCREW HEAD DIA.) EXTERNAL BOTTOM LABEL Bulletin 66 Rev. A (2/20/07) Page 4 of 8 4/2/20 5:4:9 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
5 PD20 ENCLOSURE OUTLINE DRAWING 9 6 [20] 7 2 [80] [0] [0] (4) MOUNTING HOLES A A WALL MOUNT EXAMPLE SCREW ANCHOR SECTION A-A 2 [4] 25 2 [20] 4 8 [] OVERALL HEIGHT 2 2 [9] 2 2 [52] (4) MOUNTING SCREWS #/4 X 2 /4" LENGTH MOUNTING SCREWS PREFER IF HEAD DIA. IS 7/6" [ MM] OR LESS, OTHERWISE USE #0 X 2 /4" LENGTH SCREWS (2) Ø [Ø5] HOLE 8 FOR " NPT WATERTIGHT FITTINGS OR METRIC EQUIVALENTS 2 [5] Ø 7 8 [Ø22] HOLE FOR /2" NPT WATERTIGHT FITTING OR METRIC EQUIVALENT NOTES:. ENCLOSURE RATING: UP TO NEMA 4X; IP 66, DIN DIMENSIONS: INCHES [MM].. DRAWING SCALE: /4. Bulletin 66 Rev. A (2/20/07) Page 5 of 8 4/2/20 5:4:40 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
6 TYPICAL PD20 WIRING EXAMPLE #: WIRING FOR MP45xS SERIES PROBE AND (2) 2-WIRE SENSORS TO PD20 PROBE FIELD CABLE (SEE NOTE BELOW) SENSOR FIELD CABLES (2) CONNECTORS FOR PM05/24 MODULES (SEE PAGE 8 FOR INSTALLATION) PROBE GROUND WIRE (SEE NOTE 2) FIELD PROBES OR SENSORS 2 2 2! WARNING TURN OFF POWER TO TANK MONITORING CONSOLE(S) BEFORE WIRING. INSTALL THE REQUI PM05/24 MODULES IN THE PD20 AND PD20 BEFORE SWITCHING ON POWER. FROM MP45xS SERIES PROBE GRN WHT FROM 2-WIRE SENSOR #2 FROM 2-WIRE SENSOR # EXAMPLE #2: WIRING FOR MP46xS SERIES PROBE AND -WIRE SENSOR PROBE FIELD CABLE (SEE NOTE BELOW) (2) CONNECTORS FOR PM05/24 MODULES (SEE PAGE 8 FOR INSTALLATION) TO PD20 W OR G FIELD PROBES OR SENSORS SENSOR FIELD CABLE "W" = WHITE; "G" = GREEN FROM MP46xS SERIES PROBE W OR G FROM -WIRE SENSOR IMPORTANT! WI CIRCUITS ARE NOT FUNCTIONAL UNTIL THE REQUI MODULES ARE INSTALLED (SEE PAGE 8 FOR INSTALLATION). THE PM05/24 LEFT SIDE MODULE PROTECTS THE () "GROUP " CIRCUITS ON BOTH SIDES WHILE THE RIGHT SIDE MODULE PROTECTS THE () "GROUP 2" CIRCUITS ON BOTH SIDES. NOTES:. THE PROBE FIELD CABLE SHIELD WIRE MUST BE CONNECTED IN THE PD20 CONSOLE AND SHOULD BE CUT BACK AND LEFT UNTERMINATED AT THE PD FOR THE MP45xS SERIES PROBE GROUND WIRE TO BE EFFECTIVE, THE PD20 ENCLOSURE MUST BE PROPERLY GROUNDED BY A QUALIFIED INSTALLER USING RIGID METAL CONDUIT OR OTHER APPROVED METHODS. Bulletin 66 Rev. A (2/20/07) Page 6 of 8 4/2/20 5:4:42 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
7 TYPICAL PD20 WIRING EXAMPLE: WIRING FOR PROBE, 2-WIRE SENSORS AND -WIRE SENSOR (2) CONNECTORS FOR PM05/24 MODULES (SEE PAGE 8 FOR INSTALLATION) "W" = WHITE "G" = GREEN PROBE FIELD CABLE INSTRUMENTATION SHIELD WIRE -WIRE SENSOR FIELD CABLE 2-WIRE SENSOR # FIELD CABLE 2-WIRE SENSOR #2 FIELD CABLE W OR G FIELD W OR G SHIELD WIRE 2-WIRE SENSOR #2 FIELD CABLE 2-WIRE SENSOR # FIELD CABLE -WIRE SENSOR FIELD CABLE PROBE FIELD CABLE! WARNING TURN OFF POWER TO TANK MONITORING CONSOLE(S) BEFORE WIRING. INSTALL THE REQUI PM05/24 MODULES IN THE PD20 AND PD20 BEFORE SWITCHING ON POWER. EARTH GND TO TANK MONITORING CONSOLE TO EARTH GROUND (SEE NOTE 2) TO PD20s IMPORTANT! WI CIRCUITS ARE NOT FUNCTIONAL UNTIL THE REQUI MODULES ARE INSTALLED (SEE PAGE 8 FOR INSTALLATION). EACH PM05/24 MODULE PROTECTS () CIRCUITS ON BOTH SIDES FOR GROUPS TO 2. NOTES:. THE PROBE FIELD CABLE SHIELD WIRE MUST BE CONNECTED IN THE PD20 CONSOLE AND SHOULD BE CUT BACK AND LEFT UNTERMINATED AT THE PD WARNING: TO INSURE INTRINSIC SAFETY, A 2 AWG WIRE MUST BE CONNECTED TO EACH TERMINAL. EACH WIRE MUST THEN BE CONNECTED TO THE SYSTEM EARTH GROUND (GROUND BUSS BAR) AT THE SERVICE PANEL. THE RESISTANCE BETWEEN THE EARTH GROUND TERMINAL BLOCK AND EARTH GROUND SHALL BE LESS THAN OHM. Bulletin 66 Rev. A (2/20/07) Page 7 of 8 4/2/20 5:4:44 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
8 MODULE INSTALLATION: Align cutout with polarizing key for correct installation of module as shown below. In addition, the "FIELD" side of the module must be on the same side as the "FIELD" wording on the circuit boards for PD20 and PD20. "FIELD" ON SAME SIDE MODULE PM05/24 MODULE POLARIZING CUTOUT CONNECTOR POLARIZING KEY DO NOT REMOVE PM05/24 MODULE POLARIZING CUTOUT CONNECTOR POLARIZING KEY DO NOT REMOVE "FIELD" ON SAME SIDE PD20 CIRCUIT BOARD PD20 CIRCUIT BOARD MODULE TESTING: Modules can only be tested in the PD20. Insert module into test connector and observe the LEDs. LEDs # to # (F - F) indicate good circuits. LED #4 indicates a good battery. If LED #4 does not indicate, replace the standard 9V battery and continue the test. The () module circuits are independent, therefore if () circuit fails the other (2) will continue to protect wiring. However, If the failed circuit is protecting wiring, the module must be replaced as soon as possible. See page 2 for Pneumercator module order numbers. PM05/24 MODULE MODULE TEST CONNECTOR LED # (F) FOR CIRCUIT STANDARD 9V BATTERY LED #2 (F2) FOR CIRCUIT 2 LED # (F) FOR CIRCUIT LED #4 FOR BATTERY PD20 CIRCUIT BOARD Bulletin 66 Rev. A (2/20/07) Page 8 of 8 4/2/20 5:4:47 PM, :, COPYRIGHT 20 PNEUMERCATOR COMPANY, INC.
Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationCO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE
TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...
More information4100/4120-Series Class A / Class B Zone Modules Installation Instructions
4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box
More informationGround Fault Protection. Instruction Manual
Ground Fault Protection DSP OHMNI Accessory: DSP-CA(S) Cable Adapter Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR
More informationORB TM 4-20 ma Input Box Installation & Operation Manual
IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More information115/230 VAC Digital Input Module OHDI-01
Drive IT Low Voltage AC Drives User s Manual 115/230 VAC Digital Input Module OHDI-01 OHD4 2 115/230 VAC Digital Input Module OHDI-01 Safety WARNING! All electrical installation and maintenance work on
More informationTMS Series Analog Output Board Installation Instructions
PNEUMERATOR Liquid Level ontrol Systems TMS Series Analog Output Board Installation Instructions Installation For: Model TMS2000 and Model TMS3000 OPYRIGHT 2004 PNEUMERATOR O., IN. TEL: (631) 293-8450
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More information4100/4120-Series and 4010ES Relay Modules Installation Instructions
4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description
More informationThe information in this chapter will enable you to: Understand the product's basic functions & features
C H A P T E R ➀ Chapter Objective Product Description The information in this chapter will enable you to: Understand the product's basic functions & features Introduction The RP240 is designed to operate
More informationOilCop Component Wiring Installation Manual
OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:
More informationPXC Compact Unitary Equipment Controller (UEC)
Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationSignet Pressure Transmitter
Signet 850 Pressure English *850.090* 850.090 Rev. H /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationTotal Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)
Total Home Surge Protection for Point-of-Entry FirstSurge TM User Manual - Canada (English) www.siemens.ca/surge Introduction Thank you for choosing the Siemens FirstSurge Residential Surge Protective
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationSVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL
SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 3/03 COPYRIGHT (c) 1995-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SVP48 SURGE VOLTAGE PROTECTOR is warranted
More informationZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS
ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS Please carefully read and observe all instructions and warnings contained in this manual
More informationThis network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater.
This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater. Facilitator Panel Operator Terminal RS- Panel = EOL In W = across and W = across and DX900
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationMODEL 8000MP LEVEL SENSOR
1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationSAVE THESE INSTRUCTIONS
OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.
More informationSeries ULT Ultrasonic Level Transmitter
Bulletin L-45 Series ULT Ultrasonic Level Transmitter Specifications - Installation and Operating Instructions 3 29/32 [99.21] 4 9/32 [108.74] 2X 1/2 NPT ø3 21/64 [84.53] 8 1/16 [204.79] Series ULT Ultrasonic
More informationDANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.
Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More informationFLOW MONITOR & TRANSMITTER
FLS M9.02 FLOW MONITOR & TRANSMITTER SAFETY INSTRUCTIONS General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,
More informationSVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL
SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 01/03/03 COPYRIGHT (c) 1995-2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The SVP110 SURGE VOLTAGE PROTECTOR is
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationManual No: Revision: A. TLS-4XX Consoles. Upgrade Installation Instructions
Manual No: 577013-961 Revision: A TLS-4XX Consoles Upgrade Installation Instructions Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the
More informationNow with Picture Memory
Intrasonic Technology, Inc. Color Video Door Phone / Intercom Installer s Manual Model No.V304KIT-R Now with Picture Memory Please read this manual carefully before the products are installed.technical
More informationFDS / FDS-R / FDS-PS
FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More informationFLS M9.06 PH/ORP MONITOR. safety instructions. packing List
FLS M9.06 PH/ORP MONITOR safety instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,
More informationFLS M9.06. ph/orp MONITOR
FLS M9.06 /ORP MONITOR Safety Instructions General Statements Do not install and service the product without following the Instruction Manual. This item is designed to be connected to other instruments
More informationDAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS
These commodities/technical data are controlled for export by the U.S. State Department. They may not be transferred, transshipped on a noncontinuous voyage, or otherwise be disposed of outside of the
More informationPLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!
TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationHyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series
HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series Applications Pan-Tilt-Zoom (PTZ) analog video cameras Features Individual protection circuits for analog video
More informationModel DMX8DIM Installation and Operations Manual
Model DMX8DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision June, 2018 Product description The
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationPRO II X Series CAPACITANCE PROBE
Price $5.00 PRO II X Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 9250105.fm Rev. 2 TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0
More informationInView Marquee Message Display
Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.
More informationPreparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management
Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these
More informationPRO I Series CAPACITANCE PROBE
Price $5.00 PRO I Series CAPACITANCE PROBE OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 1.0 INTRODUCTION... 4 2.0 APPLICATIONS... 4 3.0 INSTALLATION... 4 3.1
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationProduct Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box
Product Manual MNX10043 REV A MODEL DSB Dual Sensor Modular Switch box Contents Section I Overview Introduction..... 2 Description 2 DSB Model Selection.. 2 Section II Installation Mounting Instructions....
More informationManual No: Revision: F. Relay Output Modules. Installation Guide
Manual No: 576013-614 Revision: F Relay Output Modules Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationInstallation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.
Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL
LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND
More informationPRO REMOTE 25 LV CAPACITANCE PROBE
Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4
More informationVibraLINK switchable junction boxes Installation and operating guide VLL series
VibraLINK switchable junction boxes Installation and operating guide VLL series Caution: This guide should be read carefully before installation Wilcoxon Sensing Technologies 8435 Progress Drive, Frederick,
More informationModel 720 Electromechanical Hour Meter
Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More informationIntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More information*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).
PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Date: Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of stations meets DD 9, applicable
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationA0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT
A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationINSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1
DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationSignet Temperature Transmitter
Loop Output Output 7 Sensr IN (RED) Sensr V (BLACK) Signet 80 Temperature 80.090 English 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions
More informationINSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL 6U/6U- EFORE USE... Thank you for choosing M-System. efore use, please check contents
More informationUser s Manual Pulse Encoder Interface Module OTAC-01
Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians
More informationSignet 2552 Metal Magmeter Flow Sensors
Signet 2552 Metal Magmeter Flow s Features Test certificate included Award winning hot-tap magnetic flow sensor up to DN2550 (102 in.) Patented Magmeter technology* Operating range 0.05 to 10 m/s (0.15
More informationIntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
More informationUser Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)
User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationKOBOLD TDA Series Digital Temperature Transmitter
KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationInstallation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors
Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL AC Panel Transient Voltage Surge Suppressors INTRODUCTION This document explains how to install the Powerware TVSS ZoneSentinel AC Panel
More informationIRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216
More informationMicro Motion. Series 3000
Installation Manual P/N 3300991, Rev. C November 2003 Micro Motion Series 3000 Installation Manual TM Micro Motion Micro Motion Series 3000 Installation Manual For online technical support, refer to the
More informationQuickTouch (QT4) Owner s Manual
QuickTouch (QT4) Owner s Manual 4-Function Hand-Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. APPLICATION...
More informationProgrammable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual
T4111 TRANSDUCER Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual Instruction manual for use of T4111 transducer Transducer is designed for temperature
More informationMT8050iE series. Installation Instruction (1) (2)
MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationAT-CAB. Surveillance Cabinet. Installation Guide. Rev IP Sur veillance. Document part no.: G
AT-CAB Surveillance Cabinet Installation Guide Rev. 1.0 Document part no.: 625034800G IP Sur veillance CAUTION: REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. UNPACKING: Unpack carefully. Electronic components
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationSmart Wireless THUM Adapter
Reference Manual Smart Wireless THUM Adapter www.rosemount.com Reference Manual Smart Wireless THUM Adapter Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision 1 HART Device Revision
More informationHome Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video
Home Automation, Inc. Model 53A00-1 OmniTouch 5.7 Touchscreen with Video Installation Manual Document Number 53I00-1 Rev A June, 2007 FCC NOTICE This device complies with FCC Rules Part 15. Operation is
More informationOperating Instructions & Service Manual FOULS
FOULS Operating Instructions & Service Manual FOULS Basketball Player Fouls Panels Model MP-5215 EFFECTIVE S.N. 17,100, June 18, 2001 TABLE OF CONTENTS PAGE 1. GENERAL INFORMATION 3 1.1 DESCRIPTION 1.2
More informationHoneywell Model 700/800 Signal Processor and Viewing Head
Honeywell Model 700/800 Signal Processor and Viewing Head USER MANUAL Model 700ACSP Universal 85-265 VAC powered, plus 24VDC backup. Model 700DCSP 22-26VDC powered, plus 24VDC backup. The two Model 700
More informationQuick Start Guide. Measuring & Control Equipment (MACE) P/L
MACE USA LLC PO Box 7144 Overland Park, KS 66207 United States of America Ph: 888 440 4215 Fax: 888 440 6999 Email: sales@maceusa.com www.maceusa.com Measuring & Control Equipment (MACE) P/L PO Box 911,
More informationInstallation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series
Installation Manual APEX Series Silicon and MOV Panel Protection APEX Series APEX Series Installation Guide 2 Table of Contents Mechanical Installation 3 Table One - Application Rating 3 Figure 1 - Mounting
More information