Installation & Operation Guide

Size: px
Start display at page:

Download "Installation & Operation Guide"

Transcription

1 Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller B 1

2 Introduction This section provides a brief overview of the KMD-5831 Programmable Loop Controller PLC-28 and the KMD-5821 Programmable Loop Controller PLC-16 + Direct Digital Controllers. Review this material before you attempt to install the controller. For clarity we will focus on the KMD-5831 but all installation and operating instructions apply equally to the KMD Illustration 1 shows the major controller components and their locations. The KMD-5821has fewer inputs and outputs. Input Pull-Up Switches Override Board Cover Output Terminal Blocks 7 Input Terminal Blocks 8 Grounds Blank Cover AC Power Input RJ 12 Connector Isolation Lamps RS 485 Connector Status LEDs Illustration 1. Controller Components Note: Additional components are located under the blank cover. We will cover these in detail later in this document. 2

3 Installation This section provides important instructions and guidelines for installing the KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller. Carefully review this information prior to attempting installation. Mounting Use the four mounting holes to securely mount the controller using #6 hardware inside a UL-approved Enclosed Energy Management Equipment Panel or other suitable protective enclosure. Refer to Illustration " 6.00" Illustration 2. Connector Detail Input Connections Universal Inputs Wiring connections are made depending on the intended application. Sixteen Universal Inputs are provided on the controller. Observe the following guidelines. (Refer to Illustration 2.) Connect device inputs to the input terminal connections (+). Connect input grounds to the associated ground terminal (-). 3

4 Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Connecting Outputs Network Connections RJ-12 RS-485 Inputs If input pull-ups are required, refer to Configuration later in this section. Wiring terminals are suitable for up to two AWG wires. If more than two wires are required, use an external terminal strip for additional connections. Note: Pulse inputs may be used under the following conditions: If the pulse input does not use a voltage variation, then leave the input pull-up in the On position. If the pulse produces voltage peaks (up to +5 VDC max.), then the input pullup must be set to the Off position. The maximum pulse rate is 8 HZ (8 pulse/sec). Twelve Universal Outputs are available for output connections labeled as 1 12 on the output terminal blocks. The outputs are grouped into three groups of four outputs each with a shared grounds (labeled SC ) in each block.. Each output can produce 50 ma at +12 VDC. If a greater current is required, KMC recommends the use of Override Boards discussed later in this section. A separate ground block provides six additional ground connections. The controller provides connections for two types of RS 485 circuits. The RJ 12 connector provides a six-wire RS-485 connection to a modem or PC using the KMD-5559 CommTalk Data Exchange Module. Simply connect a suitable RJ-12 cable between the devices. A RS 485 terminal is available for connections to a network of controllers If the Controller is at the End-of-Line, refer to Configuration after connections are completed. Detail The End-of-Line connection will have only one wire attached to the A and B terminals. For reliable operation, use Belden cable model #82760 or equivalent (18 gauge, twisted, shielded, 50 picofarads or less) for all network terminal block connections. Connect the nodes of the network in a daisy-chain arrangement. This means: Connect the A terminal in parallel with all other A terminals. Connect the B terminal in parallel with all other B terminals. Connect the shields of the cable together at each controller. 4

5 KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Connect the shields to an earth ground (DO NOT use a chassis ground) only at one end of the segment; tape back the shield ground at the other end. Wiring Notes Use approved shielded cable and the following principles when connecting a controller to a network: Connect no more than 124 Tier 2 KMC addressable controllers or devices to the RS-485 network. Connect the nodes of the network in a daisy-chain arrangement. This means: Connect the A terminal in parallel with all other A terminals. Connect the B terminal in parallel with all other B terminals. Connect the shields of the cable together at each controller. Connect the shields to an earth ground at only one end of the segment; tape back the shield ground at the other end. Use a KMD 5575 repeater between every 32 Tier 2 controllers or if the cable length of the Tier 2 network exceeds 4000 feet (1220 meters). Use no more than seven repeaters per network. Place a KMD 5567 surge suppressor in the cable where it exits a building. Refer to Illustration 3 for an example of typical RS-485 connections. Wiring Shield Wiring Shield OR Wiring Shield KMC Controller Connections Illustration 3. Typical RS-485 Wiring Configuration 5

6 Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Override Cards For large relays or devices that cannot be powered directly from a standard output, you will need to install an output override card. Override cards provide: a wide choice of output signals. a slide switch for automatic or manual control. an LED for assessment of the output state. The following Override Cards are available from KMC Controls. Model Number HPO-6701 HPO-6702 HPO-6703 HPO-6704 HPO-6705 Output Type Triac Relay - used for switching AC voltages of 1 Amp or less. Analog Override - Used for applications requiring manual adjustment of an analog control device. N.O. Mechanical Relay (Form A) - used to switch loads of up to 2 Amps, when switching DC circuits or when a dry contact is required and the device must be OFF when power is removed ma - used for applications requiring manual adjustment of an analog control device. N.C. Mechanical Relay (Form A) - used to switch loads of up to 2 Amps, when switching DC circuits or when a dry contact is required and the device must be ON when power is removed. Note Output cards must be powered with 24 VAC to enable the manual override (HAND) function. However, this connection must not be made until the default analog output jumper is removed. Installing Override Boards Table 1. KMD-5831 Override Board Options To install an Override Board: 1. Remove the appropriate cover from the module. The upper cover is for outputs 1 8 the lower for outputs Remove the jumper from the mounting header. 3. Press the override board onto the header pins. The Hand-Off-Auto selection switch is always positioned toward the output connections. (Refer to Illustration 4.) 4. If required, set the selection switch on the Override Board. 6

7 KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Caution DO NOT connect active 24 VAC circuits to the output block unless the associated jumper is removed first. Doing so will result in damage to the output and prevent it from working. If the associated output will be an analog output, leave the jumper in place. 5. Connect output devices to the module. 6. Connect required power to the input module. Illustration 4 gives an example of a typical output module configuration. LED Selection Switch Remove jumper before installing board OR Remove jumper prior to connecting active 24 VAC circuits to the associated output terminals Illustration 4. Override Board Instalaltion Using Separate Banks The outputs are grouped into three banks that share a common switched-terminal. This connection is marked as SC on the output block. If you connect a circuit to this connector it then becomes common to all outputs in that bank. Configuration Configuration settings may be required for the inputs or the RS-485 connection. If you must activate or deactivate pull-ups on the inputs or set the end-of-line termination for the RS-485 connection, refer to Illustration 1 to locate the input switches and Illustration 6 for the End-of-Line switches. 7

8 Installation KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Input Pull-ups A 10K ohm resistor is available as a pull-up to a +5 VDC source voltage for passive or dry inputs on each input circuit. The resistor is switched On or Off using the two dip-switches at the top of the controller. The top switch is associated with the first 8 inputs and the lower switch is associated with the last 8 inputs. Illustration 5 shows on of these switches in greater detail. OFF OFF ON ON Illustration 5. Typical Input Pull-Up Switch (1 of 2) End-of-Line Switches The default setting for each input is the On position. In this position, the controller will provide +5 VDC to the input device. If the input is an active input, that is it has it s own current source, the pull-up for that input must be switched to the Off position. Illustration 6 shows the position of the End-of-Line switches associated with the RS 485 terminal. You must remove the lower blank cover to gain access to these switches End-of-Line Switches 8 Illustration 6. RS 485 End-of-Line Switches

9 KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Installation Illustration 7 shows the switch in greater detail ON OFF ON OFF Illustration 7. RS-485 End-of-Line Switch Detail Power Connection Configuration Programming If the controller is located at the end of the network segment the switches must both be placed in the default ON position. Otherwise, place the switches in the OFF position. Connect the 24 VAC supply voltage to the power connectors above the RJ 11 connector on the output side of the controller. Power is applied to the controller when the power supply (or transformer) is plugged in, as long as the Power jumper is in place. Illustration 6 shows a typical connection diagram for the controller. Note: The following guidelines apply. In general, use a separate Class 2 24 VAC transformer with the smallest VA rating that matches the specification. If several controllers are mounted in the same cabinet, you can share a transformer between them PROVIDED the transformer does not exceed 100 VA Prior to operating the controller, it must be configured using the Hardware Configuration Manager (HCM) application supplied with WinControl. Refer to the WinControl XL User s Manual for additional information. Note: All controllers on the same network must be configured for the same baud rate. Refer to the KMC Digital Applications Manual for information on how to program the controller. 9

10 Operation Controls and Indicators Status LEDs Isolation Lamps Power Jumper Resetting the Controller Once configured, programmed and powered up, the controller requires very little user intervention. The following sections describe the controls and indicators found on the card. Alternately, you may remove the RS-485 terminal block from the card to isolate the card from the network without disrupting network communications to other controllers. Two Status LEDs are located on the bottom left side of the controller. They are used to indicate the following: Communications This yellow LED flashes whenever the controller is communicating with other controllers over the RS-485 network connection. Ready This green LED indicates the controller has power and is operating normally. The LED will flash on and off at one second intervals. Two Isolation Lamps are located below the RJ 12 connector on the right side of the controller. These lamps serve three functions: Removing the lamps will open the RS-485 circuit and isolate the controller from the network. If one, or both, lamps are lit, it indicates the network is improperly phased. This means that the ground potential of the controller is not the same as other controllers on the network If the voltage or current on the network exceeds safe levels, the lamps operate as fuses to protect the controller from damage. The power jumper, shown in Illustration 8, can be used to remove power from the controller. This should be done anytime connections are made or changed on the controller. Removing the jumper opens the 24 VAC supply circuit. If the controller appears to be operating incorrectly, or is not responding to commands, you may need to reset the controller. 10

11 KMD-5831 PLC-28 Direct Digital Controller Installation & Operation Guide Operation Note Resetting the controller will restore the factory default configuration. If the devices cannot communite with the controller, or the controller cannot commnicate with other controllers, it may be necessary to re-configure the controller with HCM to establish normal communications and operation. Reprogramming may also be required. To reset the controller, proceed as follows. 1. Remove the lower Override Board cover on the controller. 2. Locate the Reset button (see Illustration 8). Watch Dog Jumper Power Jumper Reset Button Illustration 8. RS-485 End-of-Line Switch Detail 3. Locate and remove the Power Jumper from the current position. 4. Depress and hold the Reset button. 6. Reinstall the Power Jumper. (DO NOT release the Reset button.) 7. Continue to hold the Reset Button until the Communications LED flashes rapidly. 8. Release the Reset Button. This completes the reset sequence for the controller. 11

12 Disclaimer The material in this document is provided for information purposes only. The contents and the product(s) described herein are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this document. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this document. Important Notices The KMC logo is a trademark of KMC Controls, Inc. 2003, KMC Controls, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc.Printed in U.S.A. Technical Support If you have any questions about this technical document or need additional details, please call KMC Controls technical services at or e- mail us at techs@kmccontrols.com. KMC Controls P.O. Box Industrial Drive New Paris, IN U.S.A. TEL: FAX: info@kmccontrols.com B

Installation & Operation Guide

Installation & Operation Guide & Operation Guide KMD-7301/7301C Direct Digital Controller For Air Handling Applications 880-019-02C KMD 7301 and KMD 7301C Direct Digital Controller & Operation Guide Introduction This section provides

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

Installation and Operation Guide

Installation and Operation Guide Installation and Operation Guide Network -Isolator Contents Introduction...3 Installation...3 Mounting...3 Wiring and Terminal locks...4 Network Connections...4 Configuration/...7 Power Connection...7

More information

Installation and Operation Guide. KMD 5559 CommTalk

Installation and Operation Guide. KMD 5559 CommTalk Installation and Operation Guide Contents KMD 5559 CommTalk Description...3 Models...3 Specifications...3 Accessories...4 Mounting...5 Connecting the KMD 5559...5 Connecting power...9 Operation...9 Using

More information

Installation and Operation Guide

Installation and Operation Guide Installation and Operation Guide KMD 1162 NetSensor Contents Specifications... 2 Network Cable Preparation... 4 Rough-in preparation... 5 Installing the NetSensor... 5 Operation... 6 Maintenance... 7 Programming

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Installation and Operation Guide. BAC-5841/5842 UFAD and BAC / VAV Advanced Application Controllers, 8 x 8

Installation and Operation Guide. BAC-5841/5842 UFAD and BAC / VAV Advanced Application Controllers, 8 x 8 Installation and Operation Guide BAC-58/58 UFAD and BAC-58-6/58-6 VAV Advanced Application Controllers, 8 x 8 NOTE: Download these additional documents from the Partners web site! To install and properly

More information

BACnet Building Controller

BACnet Building Controller Installation and Operation Guide BAC-A1616BC BACnet Building Controller Revision BAC-A1616BC J BACnet Building Controller 1 Installation and Operation 912-019-01J Guide, Rev. J 2012, Inc. The KMC logo

More information

THE CTB08D LIGHT CONTOLLER

THE CTB08D LIGHT CONTOLLER THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Installation OVERVIEW

Installation OVERVIEW Installation OVERVIEW The DEMCO GATE ACCESS CONTROL SYSTEM is designed to operate up to 4 gates, each with an IN KEYPAD and/or an OUT KEYPAD. Each gate is wired as illustrated in the drawing of a "TYPICAL

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Rev Cutler-Hammer Smart Breaker Panel Control Manual 026-70 Rev 0 6-0-03 Cutler-Hammer Smart Breaker Panel Control Manual 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) 425-2724 Fax: (770) 425-939 ALL RIGHTS RESERVED. The information contained

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

BAC-9000 Series VAV Controller Installation Guide

BAC-9000 Series VAV Controller Installation Guide BAC-9000 Series VAV Controller Installation Guide CONTENTS Introduction... 1 Set Drive Hub (45/60 ) Rotation Limit... 1 Mount Controller... 2 Connect Sensors and Equipment... 3 Connect (Optional) Pressure

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

PLCADD1616 User Guide 3/29/10. Overview

PLCADD1616 User Guide 3/29/10. Overview PLCADD1616 User Guide 3/29/10 Overview The PLCADD1616 is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The PLCADD1616 has 16 relay outputs and 16 optically isolated

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3 EasyIO FC 20 DDC User Reference V1.3 Document Change Log 1 st April 2013 Document created. 13 th July 2013 Software configurations added. 27 th Sept 2014 FC now support pulse input. 6 th June 2015 Serial

More information

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/001 RS-485 Communications Board User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 1.1 Installation... 2 1.2 RS-422 Or RS-485 Communication

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

ADDJOG User Guide 7/30/10. Overview

ADDJOG User Guide 7/30/10. Overview ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.

More information

ETM-2050/ETM-2051 Service Manual

ETM-2050/ETM-2051 Service Manual Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note *44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11 CHAPTER TWO 2Installation IN THIS CHAPTER Checking Your Shipment Express Setup Chapter 2 Installation 11 Checking Your Shipment Inspect your shipment carefully. You should have received one or more of

More information

LCI AUXILIARY I/O TERMINAL BOARD DS200DDTBG_A

LCI AUXILIARY I/O TERMINAL BOARD DS200DDTBG_A GEI-100219 LCI AUXILIARY I/O TERMINAL BOARD DS200DDTBG_A These instructions do not purport to cover all details or variations in equipment, nor to provide every possible contingency to be met during installation,

More information

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision: INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console ACC1-25 (Part # 63971-002) ECM Motors Revision: 10.01.13 Page: 2 of 11 Table of Contents Safety Precautions...3 Overview...3 Specifications...4

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

Introduction. General Ratings

Introduction. General Ratings Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows

More information

Seven Channel Remote Control

Seven Channel Remote Control Seven Channel Remote Control Page 1 Versa7 Kit Contents The Versa7 is designed to remotely control up to seven devices, or functions. All seven functions can be controlled with the supplied four button

More information

Ethernet Adapter Installation Instructions

Ethernet Adapter Installation Instructions Ethernet Adapter Installation Instructions DOC. #569040000 A 7/30/04 PRINTED IN U.S.A. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information

More information

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA PCL451 Manual Preset Indexer User s Guide A N A H E I M A U T O M A T I O N 4985 E Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

SCD96 DMX Output Interface. Installation guide

SCD96 DMX Output Interface. Installation guide SCD96 DMX Output Interface Installation guide Contents Introduction 2 Welcome 2 Dimensions 2 Specification 2 Safety 3 Please read this first 3 Mounting 4 Location and spacing 4 Ambient atmosphere requirements

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/415 Rate Monitor Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Setting Up Your Display For Operation... 1.1 Accessing

More information

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions WCAIM2029 (Part 16022) Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions CAUTION: Flowserve recommends that all products that must be stored prior to installation be stored

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK INTRODUCTION NSI DIGITAL DIMMING SYSTEM INSTALLATION AND OPERATION GUIDE The NSI DDS 5300 and DDS 5600 dimmers represent a key part of a state of the art, integrated lighting control system. These dimmers

More information

Rev CH Breaker Gateway Installation and Operation Manual

Rev CH Breaker Gateway Installation and Operation Manual 026-1710 Rev 1 05-15-07 CH Breaker Gateway Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1 Stellar Instruments SC1 Controller & Display System General User s Manual Copyright 2013 Stellar Instruments 1 Contents Section 1 General... 3 Section 2 Base Unit A (Multi-Event Programmable Timer)...

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

OilCop Component Wiring Installation Manual

OilCop Component Wiring Installation Manual OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

LTEC Heat Pump DDC Controller

LTEC Heat Pump DDC Controller Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller

More information

NETRONICS HS3500 CONTROLLER

NETRONICS HS3500 CONTROLLER NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration Data Sheet Lighting Relay Panel Overview Leverage the Power of BAS Integration Exterior with Surface Mount Trim The Series UL Listed, Lighting Control Panel provides the capability to control high voltage

More information

ETC Installation Guide

ETC Installation Guide Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

Accessories IC690ACC900

Accessories IC690ACC900 (IC690ACC900) datasheet Features Provides the IC69* programmable controllers with an interface to devices that use the RS- interface. Allows connection to programming computer without a Work Station Interface

More information

PWRguard PLUS Spring City Drive Waukesha, WI

PWRguard PLUS Spring City Drive Waukesha, WI PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer This manual explains how to connect the HiDMUX2700 HART Multiplexer and configure Yokogawa s Plant Resource Manager (PRM) software.

More information

Vorne Industries. 87/708 Master Clock Display User's Manual

Vorne Industries. 87/708 Master Clock Display User's Manual Vorne Industries 87/708 Master Clock Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 www.vorne.com Chapter 1 Setting Up Your Display For Operation...

More information

Single Phase Systems-North American PC125/PC420 Series

Single Phase Systems-North American PC125/PC420 Series Single Phase Systems-North American PC125/PC420 Series Enclosure Power Distribution Units (epdu ) PC125-C Front RACK MOUNTED 19 x 3.4 (2U) x 8.5. Approximate shipping weight: 19 lbs. (12) NEMA OUTLETS

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275 NGC-UIT-ORD User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION The nvent RAYCHEM NGC-UIT-ORD is a panel mounted display used in conjunction with other approved

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information