1 PS-3650A/PS-3651A Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) PS-A Unit (1) (2) English and Japanese Installation Guides (one of each) <This Guide> (3) Warning/Caution Information (1) (4) Installation Gasket (1) (attached to the PS-A unit) (5) Installation Fasteners (Set of 4) (6) USB Cable Clamp (2 ports) (2) (7) Power Plug (1) AC type (5.08mm[0.2in.] pitch) DC type (7.62mm[0.3in.] pitch) Be careful when installing the PS-A not to damage the built-in HDD. This unit has been carefully packed, with special attention to quality. However, should you find anything damaged or missing, 1 please contact your local PS-A distributor immediately. When you order a PS-A unit built to your specifications, the PS-A package should include an Installation Guide for any optional items included. Please use that guide to check that all components are included in each optional item's package. About the Manual For detailed information on PS-A series, refer to the following manuals. PS-3650A/PS-3651A Series Hardware Manual PS-3650A/PS-3651A Series Reference Manual PS-3650A/PS-3651A Series API Reference Manual Manual can be downloaded from Pro-face Home Page. URL The drivers and utilities for PS-A can be downloaded from Pro-face Home Page. This Installation guide is for the following models: PS3650A-T42 PS3650A-T42-24V PS3651A-T42 PS3651A-T42-24V PS3650A-T42S PS3650A-T42S-24V PS3651A-T42S PS3651A-T42S-24V Please refer to related manuals or installation guides for PS-3650A/3651A Series that are not listed above.

2 Part Names and Functions A,B C D E Front F G Name A Display B Touch Panel C D Power LED / Status Lamp (POWER) DISK Access Lamp (DISK) Description Display Area User input is available by means of touching the panel. The lamp shows the status of the PS-A s power and operation. The display colors and their details are as follows. LED PS-A Status Normal Operation Green (lit) (power is on) Green (blinking) Soft OFF state Orange (lit) System monitor error Orange/Red Backlight burnout is detected (blinking) Not lit Power is OFF The lamp shows the status PS-A s DISK access and battery operation. The display colors and their details are as follows. LED PS-A Status Green (lit) When HDD or IDE is accessed Not lit When neither HDD nor IDE is accessed Orange (lit) PS-A is in operation with backup battery Red (lit) PS-A is in suspension with backup battery E Front Cover - F Hardware Reset Switch (RESET) Restart PS-A. 1 port. Complies with USB 1.1. Uses a TYPE-A connector. Power supply voltage DC 5V ±5% E Front USB Interface (USB) Output current Each port: 500mA(max.), 5 ports total: 500mA(max.) The maximum communication distance 5m 2

3 K L M H I I N J O J PS-3650A Series Rear PS-3651A Series P Q Q R R PS-3650A Series Side PS-3651A Series Name H Power Switch I Power Connector Description Supported by AC type only. For connection, install a power plug, which is one of accessories, to the power cable. J Mask Cover - K Expansion Board Base PS-3650A Series only. L Expansion Board Cover The PCI board installation interface is located in the cover opening. PS-3650A Series only M Expansion Board Supporter PS-3650A Series only N Fan Unit PS-3650A Series only O Memory Slot Cover PS-3651A Series only P DISK Cover PS-3651A Series only Side: comply with USB 2.0 (4 ports). TYPE-A connector. Q USB Interface (USB) Power supply voltage DC 5V ±5% Output current Each port:500ma(max.), 5 ports total:500ma(max.) The maximum communication distance 5m R PCMCIA Slot Cover 1 slot under the cover. Complies with Type II. 3

4 STU V W X S TU V W X Name S Ethernet Interface (LAN2) T Ethernet Interface (LAN1) U Y PS-3650A Series Speaker Output Interface (SPEAKER OUT) RAS Interface (RAS) V Serial Interface (COM2) W Serial Interface (COM1) X CF Card Interface Cover Bottom Description 10BASE-T/100BASE-TX/1000BASE-T Auto Changeover. This interface uses an RJ-45 type modular jack connector. 10BASE-T/100BASE-TX Auto Changeover. This interface uses an RJ-45 type modular jack connector. Mini jack connector. Y Expansion Slot PS-3650A Series only. PS-3651A Series RAS port type 2ch General-Purpose Input/Output. D-Sub 9-pin socket type. Serial 2 port type D-Sub 9-pin plug. RS-232C compliant (RI Only). D-Sub 9-pin plug. RS-232C, RS-422, RS-485 Changeover. CF card interface is under the cover. Type II-compliant slot, or Type 1 x 1 slot. When attaching peripheral units to the PS-A, be sure the PS-A's power cord is disconnected from the main power supply. General Specifications Electrical Specifications AC Power Supply DC Power Supply Input Voltage AC100/240V DC24V Rated Voltage AC85 to 265V DC19.2 to 28.8V Power Supply Rated Frequency 50/60Hz - Allowable Voltage Drop 1 cycle or less (Voltage drop interval must be 1s or more.) 5ms or less Power Consumption PS-3650A Series: 110VA or less PS-3650A Series: 80W or less PS-3651A Series: 95VA or less PS-3651A Series: 40W or less In-Rush current (room temperature) Voltage Endurance Insulation Resistance AC100V : 30A or less AC240V : 50A or less AC1,500V 20mA for 1minute (between charging and FG terminals) 30A or less AC1,000V 20mA for 1 minute (between charging and FG terminals) DC500V 10MΩ (min.) (between charging and FG terminals) 4

5 Environmental Specifications PS-3650A Series Physical Surrounding Air Temperature Storage Temperature Ambient Humidity Storage Humidity Dust Pollution Degree 0 to 50 C : without HDD 5 to 50 C : with HDD PS-3651A Series 0 to 50 C : without HDD 5 to 45 C : with HDD -20 to +60 C 10 to 90% RH (Not condensing, wet bulb temperature: 39 C or less. with HDD: 29 C or less.) 10 to 90% RH (Not condensing, wet bulb temperature:39 C or less.) 0.1mg/m 3 and below (Non-conductive levels) For use in Pollution Degree 2 environment When using any of the PS-A s optional devices, be sure to check that device s specifications for any special conditions or cautions that may apply to its use. Be aware that not only does the Hard Disk have a fixed lifetime, but that accidents can always occur. Therefore, be sure to back up your Hard Disk s data regularly, or prepare another Hard Disk unit that can be used for backup. The Hard Disk lifetime given here may be reduced due to unforeseen environmental factors, however, generally speaking, the disk should last for 20,000 hours (of operation) or approximately 5 years, whichever comes first, at an operating temperature of 20 C and 333 hours of operation per month. (HDD access frequency of 20% or less) Using the Hard Disk in an environment that is excessively hot and/or humid will shorten the disk s usage lifetime. A wet bulb temperature of 29 C or less is recommended. This is equivalent to the following data. Temperature at 35 C at 40 C Humidity no higher than 64% RH no higher than 44% RH In order to extend the lifetime of the hard disk, Pro-face recommends you set the Windows XP (classic) [Control panel]-[power Options]-[Power Options Properties]- [Power Schemes]-[Turn off hard disks] selection to turn the hard disk off when the unit is not being operated. A setting of 5 minutes is recommended. DIP Switches 1. Changing Settings To set the DIP switches which are on the PS-A s circuit board, remove the PS-A s Fan Unit or Memory Slot Cover. Use a screwdriver to loosen or tighten the screws. Be sure not to tighten screws too tightly, since it may damage the unit. Be careful when removing or inserting any screws that they do not fall inside the PS-A. (1) Turn OFF the power switch of the PS-A and remove the power cable. Place the PS-A on a flat, level surface facing the display face downwards. 5

6 (2) Unscrew the screws (2) as you see on the following figure, then remove the Fan Unit or the Memory Slot Cover. PS-3650A Series PS-3651A Series 2. DIP Switches Configuration Be sure to confirm what settings will be used by the other device and set the slide switches accordingly. Failure to do so can result in a unit malfunction or damage. Whenever changing the PS-A switches, be sure to first turn the PS-A's power supply OFF. Failure to do so can cause a PS-A malfunction. DIP Switch Locations Switch Location Switch Name Description A System Set SW1 10-point DIP switch. For the switches details, see Table (1). B Serial Mode 10-point DIP switch. Designates COM1 communication settings. For the switches details, see Table (2). Select SW C System Set SW2 4-point DIP switch. For the switches details, see Table (3). 6

7 Switch No. Description ON OFF Notes 1 Used for the system. Reserved Reserved Factory Settings: ON 2 Used for the system. Reserved Reserved Factory Settings: OFF 3 Change Reset SW mode. *1 Power button Reset SW Factory Settings: OFF Sets up an enabled/disabled state 4 for the port execution control Disabled Enabled Factory Settings: OFF function of hardware reset switch. *1 5 Used for the system. Reserved Reserved Factory Settings: OFF 6 Sets up an enabled/disabled state for the front USB port execution control function. *2 Disabled Enabled Factory Settings: OFF 7 Used for the system. Reserved Reserved Factory Settings: OFF 8 Cancellation function of pushing two points on the touch panel Enabled 9 Used for the system. Reserved Reserved Factory Settings: OFF Changes COM1's # 9 pin +5V 10 (RI <---> +5V). RI Factory Settings: OFF Output Enabled only when RS-232C mode Table 1) System Set Switch 1 *1 The PS-A restarts when pressing the switch in the Soft OFF state. Soft OFF means Windows has been shut down and the power is provided only for the electric circuit to boot system. This Soft OFF State is different from System Standby set by Windows. *2 Setting up an enabled/disabled state for the USB port execution control function is available for only Windows. Make sure to disable the function of the setting when using another OS. Factory setting is RS-232C. Only SW No.1 is ON. Switch No Disabled Factory Settings: OFF The middle point is not considered to be touched when the SW is ON. It is considered to be touched when the SW is OFF. Description ON OFF RS-232C RS-422 RS-485 Changes COM1's communication method. Changes COM1's communication method. Changes COM1's communication method. Changes TX data's output mode. RS-232C RS-422/RS-485 ON OFF OFF RS-422/RS-485 RS-232C OFF ON ON RS-422/RS-485 RS-232C OFF ON ON TX data output is controlled via the RTS signal. TX data output is NOT controlled via the RTS signal. (normally output) OFF ON/OFF ON/ OFF *1

8 Switch No Description ON OFF RS-232C RS-422 RS-485 Switches the TX termination resistance ON/OFF. Switches the RX termination resistance ON/OFF. Switches the shorting of TXA and RXA ON or OFF. Switches the shorting of TXB and RXB ON or OFF Inserts termination resistance of 220Ω between TXA and TXB. Inserts termination resistance of 220Ω between RXA and RXB. Shorts TXA and RXA (RS-485 mode) Shorts TXB and RXB (RS-485 mode) No termination OFF ON No termination OFF ON No shorting (RS-422 mode) No shorting (RS-422 mode) ON/ OFF *2 ON/ OFF *2 OFF OFF ON OFF OFF ON 9 RTS Automatic control The data is The data is not OFF OFF mode automatically automatically (enabled only when controlled via the controlled via the 10 RS-485 mode). RTS signal. RTS signal. OFF OFF ON/ OFF *1 ON/ OFF *1 Table 2) Serial Mode Select Switch Serial Mode Select Switches (SW4 to SW10) operate as shown in the circuit diagram below. RTS Automatic control *1 To enable RTS automatic control of the TX output driver, set SW No. 9 and 10 ON, and set SW No. 4 OFF. To enable control of the TX output driver via RTS signals, set SW No. 9 and 10 OFF, and set SW No. 4 ON *2 If you use the termination resistance, base your settings on the connection specifications. 8

9 Switch No. Description ON OFF Notes 1 Changeover of a Master/Slave setting for primary CF Card I/F. Master Slave Factory Settings: ON 2 Used for the system. Reserved Reserved Factory Settings: OFF 3 Change Reset SW mode. *1 Enabled Disabled Factory Settings: OFF 4 Used for the system. Reserved Reserved Factory Settings: OFF Table 3) System Set Switch 2 *1 In SOFT OFF state, input to RAS Interface DIN1(+), will start the PS-A. RAS port type only. External Interfaces Serial Interface (COM1, COM2) The PS-A unit side connector is a D-Sub 9 pin plug type. Interfit Bracket #4-40 (UNC) COM2 is an interface for the serial 2 port type only. Do not connect any pins to [NC]. Connect the FG terminal line to the shell. Always connect the #5 SG (Signal Ground) of the PS-A unit to the connected device, especially if the connected device is also not isolated. Failure to do so may damage the RS232C/RS422/RS485 circuit. FG and SG terminals are internally connected in the PS-A. When connecting to another device, be sure not to create an SG shorting loop in your system. COM1 COM1can be changed to RS-232C, RS-422 or RS-485. (The factory setting is RS-232C.) To change this setting, open the PS-A unit's FAN Unit or Memory Slot Cover and set DIP switch on the circuit board to the desired position. Please refer to DIP Switches on page 5 for details. Pin # RS-232C Signal Name Description 1 CD Carrier Detect 2 RD(RXD) Receive Data 3 SD(TXD) Send Data 4 ER(DTR) Data Terminal Ready 5 GND Signal Ground (SG) 6 DR(DSR) Data Set Ready 7 RS(RTS) Request to Send 8 CS(CTS) Clear to Send Called status display 9 CI(RI)/+5V *1 /+5V Output (Switching available) Shell FG Frame Ground (Common with SG) *1 To change pin 9 s RI/+5V setting, open the PS-A unit's rear cover and set the slide switch to the desired position. Please refer to DIP Switches on page 5 for details. Pin RS-422 # Signal Name Description 1 RDA Receive Data A (+) 2 RDB Receive Data B (-) 3 SDA Send Data A (+) 4 NC No Connection 9

10 Pin RS-422 # Signal Name Description 5 GND Signal Ground (SG) 6 NC No Connection 7 SDB Send Data B (-) 8 NC No Connection 9 NC No Connection Shell FG COM2 Frame Ground (Common with SG) Pin RS-485 # Signal Name Description 1 DATA + Send/Receive Data(+) 2 DATA - Send/Receive Data(-) 3 NC No Connection 4 NC No Connection 5 GND Signal Ground (SG) 6 NC No Connection 7 NC No Connection 8 NC No Connection 9 NC No Connection Shell FG Frame Ground (Common with SG) Pin RS-232C # Signal Name Description 1 CD Carrier Detect 2 RD(RXD) Receive Data 3 SD(TXD) Send Data 4 ER(DTR) Data Terminal Ready 5 GND Signal Ground (SG) 6 DR(DSR) Data Set Ready 7 RS(RTS) Request to Send 8 CS(CTS) Clear to Send 9 CI(RI) Called status display Shell FG Frame Ground (Common with SG) RAS Interface The PS-A unit side connector is a D-Sub 9 pin socket type. Interfit Bracket #4-40(UNC) RAS is an interface for RAS port type only. Be sure to use only the rated voltage level when using pin # 1 (+12V) for external power output. Failure to do so can lead to a unit malfunction or accident. Pin # Signal Name Description 1 +12V Output Current: 100mA or less Output Voltage: 12V±5% 2 DOUT0(+) Data out 0(+) 3 DOUT1(+) Data out 1(+) 4 DIN0(+) Data in 0(+) 5 DIN1(+) Data in 1(+) *1 6 GND Ground 7 DOUT0(-) Data out 0(-) 8 DOUT1(-) Data out 1(-) 9 DINCOM Data in common *1 This pin can be used as an input start or external reset input of the RAS feature. The factory setting is data input. For the circuit diagram, refer to PS-3650A/ PS-3651A Series Hardware Manual. 10

11 Installations 1. Installation Requirements For easier maintenance, operation, and improved ventilation, be sure to install the PS-A at least 50mm [1.97 in.] away from adjacent structures and other equipment. Unit:mm[in.] 2. PS-A Installation (1) Create a Panel Cut following the dimensions in the table below. Also, determine the panel thickness according to the panel thickness range with due consideration of panel strength. Unit: mm [in.] X 4-R3[0.12] or less Panel thickness 50 [1.97] 50 [1.97] 50 [1.97] 50 [1.97] 50 [1.97] PS-A Y 50 [1.97] 50 [1.97] Be sure that the surrounding air temperature and the ambient humidity are within their designated ranges. Surrounding air temperature 0 to 50 C: (with HDD: PS-3650A - 5 to 50 C, PS-3651A - 0 to 45 C). Ambient humidity: 10 to 90%RH (wet bulb temperature: 39 C or less, with HDD 29 C or less). When installing the PS-A on the panel of a cabinet or enclosure, Surrounding air temperature indicates both the panel face and cabinet or enclosure s internal temperature. Unit:mm[in.] Panel Face Inside Cabinet PS-A X Y PS- 3650A [ ] [ ] -0-0 Panel thickness 1.6[0.06] to 10.0[0.39] (2) Confirm that the installation gasket is attached to the PS-A unit and then place the PS-A unit into the Panel from the front. It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to repelling water. To replace the installation gasket, see PS-3650A/PS-3651A Series Hardware Manual. 50 [1.97] 30[1.18] 30[1.18] Be sure that heat from surrounding equipment does not cause the PS-A to exceed its standard operating temperature. 11

12 (3) Insert each fastener s hook into the slot and tighten it with a screwdriver. Insert the installation fasteners securely into the insertion slot recess. There are eight insertion slots. Insertion Slots Supplying a power voltage other than that specified can damage the PS-A and the power supply. Since the DC power supply Type has no power ON/OFF switch, be sure to attach a breaker-type switch to its power cord. When the FG terminal is connected, be sure the wire is grounded. Insertion Slot Recess Hook the fastener on the Recess, Panel PS-A Tightening the screws with too much force can damage the PS-A unit. The necessary torque is 0.5N m. Be sure to insert installation fasteners in the recessed portion of an installation fasteners hole. If the fasteners are not correctly attached, the PS-A unit may shift or fall out of the panel. Wiring Installation Fastener Hook and secure the fastener on the panel with a screw. To avoid an electric shock, prior to connecting the PS-A unit s power cord terminals to the power terminal block, confirm that the PS-A unit s power supply is completely turned OFF, via a breaker, or similar unit. When the FG terminal is connected, be sure the wire is grounded. Not grounding the PS-A unit will result in excessive noise. Use your country's applicable standard for grounding. Power Cord Specifications Use copper conductors only. Power Cord Diameter Conductor Type Conductor Length 0.75 to 2.5mm 2 (18 to 12 AWG) Solid or Stranded Wire *1 *1 If the Conductor s end (individual) wires are not twisted correctly, the end wires may either short against each other, or against an electrode. Wiring When connecting the power cord, use the following items when performing wiring. (Items are made by Phoenix Contact.) Recommended Driver Recommended Pin Terminals 10mm [0.39in.] SZS 0.6x3.5 ( ) AI GY ( ) AI 1-10RD ( ) AI BK ( ) AI BU ( ) 12

13 Recommended Pin Terminal Crimp Tool CRIMPFOX ZA3 ( ) Accompanying AC type power supply plug is CA7-ACCNL-01 from Pro-face or FKC2.5/3-STF-5.08 is manufactured by Phoenix Contact. Accompanying DC type power supply plug is CA7-DCCNL-01 from Pro-face or GFKC2.5/3-STF-7.62 is manufactured by Phoenix Contact. Connecting the Power Cord (1) Confirm that the power is not supplied to the PS-A unit. (2) Push the Opening button with a small and flat screw driver to open the desired pin hole. (3) Insert each pin terminal into its each hole. Release the Opening button to clamp the pin in place. Opening Button AC power supply cord L Black N White FG Green/Yellow DC power supply cord Opening Button To prevent the possibility of a terminal short, use a pin terminal that has an insulating sleeve. 1. Power Supply Cautions Input and Output signal lines must be separated from the power control cables for operational circuits. To improve the noise resistance, be sure to twist the ends of the power cord wires before connecting them to the Power Plug. The PS-A unit s power supply cord should not be bundled with or kept close to main circuit lines (high voltage, high current), or input/output signal lines. To reduce noise, make the power cord as short as possible. If the supplied voltage exceeds the PS-A unit s range, connect a voltage transformer. Between the line and the ground, be sure to use a low noise power supply. If there is an excess amount of noise, connect a noise reducing transformer. The temperature rating of field installed conductors: 75 C only. Use voltage and noise reducing transformers with capacities exceeding Power Consumption value. Connect a surge absorber to handle power surges. (4) After inserting all three pins, insert the Power Plug into the Power Connector at PS-A. Fix the plug with two (2) slot screws. Confirm that all wires are connected correctly. The torque required to tighten these screws is 0.5 to 0.6N m. Be sure to ground the surge absorber (E1) separately from the PS-A unit (E2). Select a surge absorber that has a maximum circuit voltage greater than that of the peak voltage of the power supply. E1 FG E2 PS-A Lightning Surge Absorber 13

14 2. Grounding Cautions Be sure to create an exclusive ground for the Power Cord s FG terminal. Use a grounding resistance of 100Ω, a wire of 2mm 2 or thicker, or your country s applicable standard. The SG (signal ground) and FG (frame ground) terminals are connected internally in the PS-A unit. When connecting the SG line to another device, be sure that the design of the system/connection does not produce a shorting loop. The grounding wire should have a cross sectional area greater than 2mm 2. Create the connection point as close to the PS-A unit as possible, and make the wire as short, as possible. When using a long grounding wire, replace the thin wire with a thicker wire, and place it in a duct. 3. Input/Output Signal Line Cautions All PS-A Input and Output signal lines must be separated from all operating circuit (power) cables. If this is not possible, use a shielded cable and ground the shield. To improve noise immunity, it is recommended to attach a ferrite core to the power cord. Exclusive Grounding (BEST) Other PS-A unit Equipment Common Grounding (OK) PS-A unit Other Equipment Common Grounding (Not OK) PS-A unit Other Equipment 14

15 To prevent the USB cable from coming off When using a USB device, attaching the USB holder to the USB Interface located on the side of the PS-A unit prevents the USB cable Interface from becoming disconnected. The USB holder cannot be attached to the USB Interface located on the front of the PS-A. Attaching the USB Holder (1) Before starting the procedure, lift up the tab on both sides of the USB Holder and remove the USB Cover. Tab (4) Insert the USB cover into the tab of the USB holder to fix the USB cable. Tab USB Cover In case of installing the second USB cable, repeat the steps (3) and (4). When attaching the USB holder, be sure to attach both USB covers, no matter how many USB cables are connected. Removing the USB Holder Remove USB Holder by the reverse procedures to the attachment procedures. (1) Lift up the tab of the USB holder and then remove the USB cover. Tab (2) Attach the USB holder to the USB Interface on the side of the PS-A unit. Hook the upper pick of the USB holder to the attachment hole of the PS-A unit and then insert the lower pick as shown below to fix the USB holder. Pick (1) (2) Remove the USB cable. (3) Remove the picks pushing the USB holder from both top and bottom and then remove the USB holder from PS-A unit. (2) USB Cover (3) Insert the USB cable into the USB Interface. USB Cable 15

16 Installation prerequisites for standards The following units are UL/c-UL listed products: (UL/c-UL File No.E220851) Product Model No. UL/c-UL Registration Model No. PS3650A-T42 PS3650A-T42S PS3651A-T42 PS3651A-T42S PS3650A-T42-24V PS3650A-T42S-24V PS3651A-T42-24V PS3651A-T42S-24V For the detailed certification's information, refer to the Pro-face Home page. <Cautions> Be aware of the following items when building the PS-A into an end-use product: The PS-A unit s rear face is not approved as an enclosure. When building the PS-A unit into an end-use product, be sure to use an enclosure that satisfies standards as the end-use product s overall enclosure. The PS-A unit must be used indoors only. Install and operate the PS-A with its front panel facing outwards. If the PS-A is mounted so as to cool itself naturally, be sure to install it in a vertical panel. Also, it s recommended that the PS- A should be mounted at least 50mm [1.97in.] away from any other adjacent structures or machine parts. The temperature must be checked on the final product in which the PS-A is installed. For use on a flat surface of a Type 4X (Indoor Use Only) and/or Type 12 Enclosure. Type 4X (Indoor Use Only) and/or 12 Enclosure, when the hatch for Front USB Port is secured with a screw. Type 1 Enclosure, when the hatch for Front USB Port is open. 16 CE Marking PS3650A-T42, PS3650A-T42S, PS3651A- T42, PS3651A-T42S units are CE marked product that conforms to EMC directives and Low Voltage Directives. PS3650A-T42-24V, PS3650A-T42S-24V, PS3651A-T42-24V, PS3651A-T42S-24V units are CE marked product that conforms to EMC directives. For the detailed information, please be downloaded and refer the Declaration of Conformity from Pro-face Home Page. Inquiry Do you have any questions about difficulties with this product? Please access our site anytime that you need help with a solution. Note Please be aware that Digital Electronics Corporation shall not be held liable by the user for any damages, losses, or third party claims arising from the uses of this product. Digital Electronics Corporation Nanko-higashi Suminoe-ku, Osaka JAPAN TEL: +81-(0) FAX: +81-(0) Copyright 2009 Digital Electronics Corporation. All rights reserved. PFX104904F.PS365XA-MT03E-BTH JM/C

17 Addendum Anexo Annexe PHA /2018 California Proposition 65 Warning Lead and Lead Compounds Advertencia de la Proposición 65 de California Plomo y compuestos de plomo Avertissement concernant la Proposition 65 de Californie Plomb et composés de plomb WARNING: This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to: ADVERTENCIA: Este producto puede exponerle a químicos incluyendo plomo y compuestos de plomo, que es (son) conocido(s) por el Estado de California como causante(s) de cáncer y defectos de nacimiento u otros daños reproductivos. Para mayor información, visite : AVERTISSEMENT: Ce produit peut vous exposer à des agents chimiques, y compris plomb et composés de plomb, identifiés par l'état de Californie comme pouvant causer le cancer et des malformations congénitales ou autres troubles de l appareil reproducteur. Pour de plus amples informations, prière de consulter: All trademarks are the property of Schneider Electric SE, its subsidiaries, and affiliated companies. Schneider Electric USA, Inc. 800 Federal Street Andover, MA USA Todas las marcas comerciales son propiedad de Schneider Electric SE, sus filiales y compañías afiliadas. Importado en México por: Schneider Electric México, S.A. de C.V. Av. Ejercito Nacional No. 904 Col. Palmas, Polanco México, D.F Toutes les marques commerciales sont la propriété de Schneider Electric SE, ses filiales et compagnies affiliées. Schneider Electric Canada, Inc McLaughlin Road Mississauga, ON L5R 1B8 Canada Schneider Electric All Rights Reserved / Reservados todos los derechos / Tous droits réservés

USB-Serial (RS-232C) Conversion Cable Installation Guide. Package Contents. Safety Precautions. Unit Disposal

USB-Serial (RS-232C) Conversion Cable Installation Guide. Package Contents. Safety Precautions. Unit Disposal USB-Serial (RS-232C) Conversion Cable Installation Guide This product is a conversion cable for using an USB I/F of your product as the Serial (RS- 232C) I/F. For the detailed information on the corresponding

More information

About the Manual. ST-3400 Series Installation Guide. Package Contents

About the Manual. ST-3400 Series Installation Guide. Package Contents ST-3400 Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents About the Manual For the detailed information

More information

About the Manual. ST-3300 Series Installation Guide. Package Contents

About the Manual. ST-3300 Series Installation Guide. Package Contents ST-3300 Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents About the Manual For the detailed information

More information

PS-3710A Series Installation Guide. About the Manual. Package Contents. URL

PS-3710A Series Installation Guide. About the Manual. Package Contents. URL PS-3710A Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) PS-A Unit (1) (2) Installation Guide

More information

About the Manual. AGP3300-U1-D24 Installation Guide. Package Contents

About the Manual. AGP3300-U1-D24 Installation Guide. Package Contents AGP3300-U1-D24 Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) GP Unit (1) (2) English and Japanese installation

More information

PS-3710A Series Installation Guide. Package Contents. About the Manual. URL

PS-3710A Series Installation Guide. Package Contents. About the Manual. URL PS-3710A Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) PS-A Unit (1) (2) English and Japanese Installation

More information

Preface NOTICE. Copyright 2007 Digital Electronics Corporation. All rights reserved.

Preface NOTICE. Copyright 2007 Digital Electronics Corporation. All rights reserved. Preface Thank you for purchasing Pro-face s PS-3650A Series Battery Unit. This manual outlines the functions of the Battery Unit and settings for the Battery Unit driver. Before operating your Battery

More information

PS-3711A Series Installation Guide. Package Contents. About the Manual. URL

PS-3711A Series Installation Guide. Package Contents. About the Manual. URL PS-3711A Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) PS-A Unit (1) (2) English and Japanese Installation

More information

About the Manual. AGP3300-U1-D24 Installation Guide. Package Contents

About the Manual. AGP3300-U1-D24 Installation Guide. Package Contents AGP3300-U1-D24 Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) GP Unit (1) (2) English and Japanese installation

More information

GP-4100 Series Installation Guide. About the Manual. GP-4100 Series Connection Types. Package Contents. Global Code

GP-4100 Series Installation Guide. About the Manual. GP-4100 Series Connection Types. Package Contents. Global Code GP-4 Series Installation Guide Please read the "Warning/Caution Information" on the attached sheet before using the product. GP-4 Series Connection Types RS-232C type RS-422/485 type RS-485 (isolation)

More information

About the Manual. GP3000 Series CANopen Interface Installation Guide. Package Contents

About the Manual. GP3000 Series CANopen Interface Installation Guide. Package Contents GP3000 Series CANopen Interface Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. About the Manual For the detailed information

More information

9487 Flat Panel Industrial PCs DS (P)

9487 Flat Panel Industrial PCs DS (P) Xycom Automation, Inc. is a subsidiary of Pro-face America, Inc. 9487 Flat Panel Industrial PCs DS-099330-001(P) The 9487 color NEMA 4/4X/12 Industrial Flat Panel Computers offer a compact, modular package,

More information

PL-3900T Series Installation Guide. Package Contents. About the Manuals

PL-3900T Series Installation Guide. Package Contents. About the Manuals PL-3900T Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents (1) PL Unit (1) (2) Installation Guide (1)

More information

1600 RAID-Enabled Industrial PCs

1600 RAID-Enabled Industrial PCs Xycom Automation, Inc. is a subsidiary of Pro-face America, Inc. 1600 RAID-Enabled Industrial PCs The most susceptible component of any Industrial PC is the hard drive. Some sources suggest shock mounting

More information

About the Manual. GP-3200 Series Installation Guide. Package Contents

About the Manual. GP-3200 Series Installation Guide. Package Contents GP-3200 Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents About the Manual For the detailed information

More information

5015T/R2 Industrial Flat Panel Touch Monitor

5015T/R2 Industrial Flat Panel Touch Monitor Industrial Flat Panel Touch Monitor United States Canada Mexico DS-300005(D) F E A T U R E S 15-inch Color LCD Touch Monitor AC100/240V DC18/30V XGA 15-inch Pro-face/Xycom s 15" industrial flat panel touch

More information

3300 Series Heavy-Duty Flat Panel Industrial PCs

3300 Series Heavy-Duty Flat Panel Industrial PCs 3300 Series Heavy-Duty Flat Panel Industrial PCs Xycom Automation's open solutions connect to other automation standards with Industrial PCs that are more than tough enough for plant floor use. (Our standard

More information

1600 Industrial Rack Mount PCs

1600 Industrial Rack Mount PCs Xycom Automation, Inc. is a subsidiary of Pro-face America, Inc. 1600 Industrial Rack Mount PCs DS-160000(G) with Pentium 4 (Includes 1612, 1613, & 1614) F E A T U R E S Rack mount 4U height and 3 sizes

More information

5012KPM(T) and 5015KPM(T)

5012KPM(T) and 5015KPM(T) United States Canada Mexico 5012KPM(T) and 5015KPM(T) Flat Panel Industrial Touch Monitors DS-300004(D) F E A T U R E S 12 and 15-inch Color LCD Touch Monitor 5012KPM(T)/ 5015KPM(T) AC100/240V DC28/30V

More information

1546 Heavy-Duty Industrial PC

1546 Heavy-Duty Industrial PC 1546 Heavy-Duty Industrial PC without Integrated Display United States Canada Mexico F E A T U R E S DS-154600(C) 1546 Models: 1546-1300 CPU: Intel Celeron M 1.3GHz AC100/240V 2-year warranty 4X AGP graphics

More information

4115T Light-Duty Flat Panel Thinline Industrial Computer

4115T Light-Duty Flat Panel Thinline Industrial Computer 4115T Light-Duty Flat Panel Thinline Industrial Computer DS-304115(C) F E A T U R E S NEW! Faster CPU! Xycom Automation industrial computers (IPCs) are designed to provide processing power and versatility.

More information

WARNING WARNING WARNING

WARNING WARNING WARNING WARNING UNINTENDED EQUIPMENT OPERATION Do not use the unit as the only means of control for critical system functions such as motor start/stop or power control. Failure to follow these instructions can

More information

4700 Series RAID-Enabled Industrial PCs DS _RAID(C)

4700 Series RAID-Enabled Industrial PCs DS _RAID(C) 4700 Series RAID-Enabled Industrial PCs DS-470000_RAID(C) The most susceptible component of any Industrial PC is the hard drive. Some sources suggest shock mounting the hard drive; unfortunately, shock

More information

OpenCLIENT Industrial Windows Terminals and Nodes

OpenCLIENT Industrial Windows Terminals and Nodes OpenCLIENT Industrial Windows Terminals and Nodes DS-370040(F) F E A T U R E S Enabled by ACP ThinManager (ThinManager sold separately) 8.4 & 10.4 color flat panel display terminals or non-integrated display

More information

GP-3300/3400 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2)

GP-3300/3400 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) GP-3300/3400 Series Installation Guide (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) (GP-3400 Series) Caution Be sure to read the Warning/Caution Information on the attached sheet before using

More information

4715 Industrial PCs. with Integrated 15.0" LCD Displays

4715 Industrial PCs. with Integrated 15.0 LCD Displays United States Canada Mexico 4715 Industrial PCs with Integrated 15.0" LCD Displays Pro-face America's newest generation of Xycom industrial PCs are designed and tested for the tough environments required

More information

4600 Series RAID-Enabled

4600 Series RAID-Enabled 4600 Series RAID-Enabled Industrial PCs 12 and 15-inch Color LCD Touch Monitor 4612/ 4615/ 1546 AC100/240V SVGA XGA Models: 4612T-1300 RAID/ 4615T-1300 RAID/ 1546-1300 RAID 12-inch 15-inch Windows 2000

More information

3615 Industrial PCs 15.0" LCD Flat Panel Display DS (E)

3615 Industrial PCs 15.0 LCD Flat Panel Display DS (E) 3615 Industrial PCs 15.0" LCD Flat Panel Display DS-361500(E) Xycom Automation's newest generation of industrial PCs is designed and tested for the tough environments required for plant floor use. Our

More information

133 MHz system bus. A Pentium III 1.26 GHz CPU with 512K cache, running at 133 MHz bus is an available option. Fits Your Needs

133 MHz system bus. A Pentium III 1.26 GHz CPU with 512K cache, running at 133 MHz bus is an available option. Fits Your Needs 3612 Industrial PCs 12.1" LCD Flat Panel Display DS-361200(G) Xycom Automation's newest generation of industrial PCs are designed and tested for the tough environments required for plant floor use. Our

More information

4600 Series Industrial PCs with Integrated 12.1" or 15.0" LCD Displays

4600 Series Industrial PCs with Integrated 12.1 or 15.0 LCD Displays 4600 Series Industrial PCs with Integrated 12.1" or 15.0" LCD Displays 12 and 15-inch Color LCD Touch Monitor 4612/ 4615 Models: 4612T-1300 / 4615T-1300 CPU: Intel Celeron M 1.3GHz AC100/240V SVGA XGA

More information

5015SLR Sunlight Readable Flat Panel Monitor

5015SLR Sunlight Readable Flat Panel Monitor Sunlight Readable Flat Panel Monitor 15-inch Color LCD Touch Monitor AC100/240V DC19/30V XGA DS-(B) Pro-face/Xycom s Sunlight Readable 15" industrial flat panel touch monitor offers state-of-the-art performance

More information

GP-4201TM/4301TM Installation Guide

GP-4201TM/4301TM Installation Guide GP-4201TM/4301TM Installation Guide Please read the "Warning/Caution Information" on the attached sheet before using the product. Table of Contents Package Contents..............................................

More information

GP3000H Series Installation Guide. Package Contents. About the Manual. (8) Emergency Switch Guard (1) Attachment Screws (3) *1

GP3000H Series Installation Guide. Package Contents. About the Manual. (8) Emergency Switch Guard (1) Attachment Screws (3) *1 GP3000H Series Installation Guide (8) Emergency Switch Guard (1) Attachment Screws (3) *1 Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package

More information

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350 Surge Protective Devices Installation & Operation Manual NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 50 ASCO SURGE PROTECTIVE DEVICE INSTALLATION, OPERATION AND MAINTENANCE MANUAL TABLE OF CONTENTS INSTALLATION

More information

LT-3300 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (1 set) (Holder: 1, Cover: 1)

LT-3300 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (1 set) (Holder: 1, Cover: 1) LT-3300 Series Installation Guide (9) USB Cable Clamp (1 set) (Holder: 1, Cover: 1) Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. (10) EX module

More information

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as

More information

Description. Green. Red. Orange

Description. Green. Red. Orange GP3000 Series DIO Interface Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. CAUTION This manual describes the part names and general

More information

GP-3300/3400 Series Installation Guide. Package Contents. About the Manual. Distribué par : (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2)

GP-3300/3400 Series Installation Guide. Package Contents. About the Manual. Distribué par : (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) GP-3300/3400 Series Installation Guide (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) (Only for GP-3400 Series) Caution Be sure to read the Warning/Caution Information on the attached sheet

More information

GP-3500/3600/3700 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2)

GP-3500/3600/3700 Series Installation Guide. Package Contents. About the Manual. (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) GP-3500/3600/3700 Series Installation Guide (9) USB Cable Clamp (2 port) (1 set) (Holder: 1, Cover: 2) Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product.

More information

PS345XA-HD40 Installation Guide. About the Manual. Safety Cautions. URL

PS345XA-HD40 Installation Guide. About the Manual. Safety Cautions. URL PS345XA-HD40 Installation Guide The PS345XA-HD40 is the hard disk unit (HDD unit) for Pro-face s PS-3450A Series (hereafter referred as the "PS-A") units and PS3000-BA Series (hereafter referred as the

More information

Preface. Essential Safety Precautions

Preface. Essential Safety Precautions Preface The PS365XA-HD40 is the hard disk unit (HDD unit) for Pro-face s PS-3650A/PS- 3710A Series (hereafter referred as the "PS-A") units. This 2.5 inch 40GB hard disk is designed to be installed inside

More information

NEW in BLUE Open Studio SP2

NEW in BLUE Open Studio SP2 SCADA/HMI Software for Intuitive Dashboards, OEE, and the Internet of Things. NEW in BLUE Open Studio 8.0 + SP2 Import Wizards for FactoryTalk, PanelMate, and PanelView (Add-Ons) Minimize migration costs

More information

Package Contents. GP Options (Made by Digital)

Package Contents. GP Options (Made by Digital) When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's

More information

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual GP3000H Direct-connect Cable Installation Guide Thank you for purchasing Pro-face s GP3000H Hard-type/Soft-type Directconnect Cable (Hereafter referred to as this cable ). This optional cable connects

More information

FP-3710T Series Installation Guide

FP-3710T Series Installation Guide FP-3710T Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents FP unit (1) Installation Guide (1) (this manual)

More information

RS-232C/485 Isolation Unit Installation Guide. Essential Safety Precautions WARNINGS

RS-232C/485 Isolation Unit Installation Guide. Essential Safety Precautions WARNINGS RS-232C/485 Isolation Unit Installation Guide Thank you for purchasing Pro-face's RS-232C/485 Isolation Unit (CA3-ISO232-01/ CA3-ISO485-01). This unit is designed utilize Pro-face product,display(unit)

More information

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual

Package Contents. GP3000H Direct-connect Cable Installation Guide. Safety Precautions. About the Manual GP3000H Direct-connect Installation Guide Thank you for purchasing Pro-face s GP3000H Hard-type/Soft-type Directconnect (Hereafter referred to as this cable ). This optional cable connects GP3000H series

More information

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

PFXGP4503TAD.   Pro-face Xycom GP4000 PFXGP4503TAD PFXGP4503TAD http://www.axcontrol.com/automation/pro-face/gp-4000/pfxgp4503tad Pro-face Xycom GP4000 PFXGP4503TAD Pro-face Xycom GP-450xT GP450xT Touch Screen Operator Interface 10.4 TFT Analog Color LCD

More information

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

PFXGP4601TAD.   Pro-face Xycom GP4000 PFXGP4601TAD PFXGP4601TAD http://www.axcontrol.com/automation/pro-face/gp-4000/pfxgp4601tad Pro-face Xycom GP4000 PFXGP4601TAD Pro-face Xycom GP-460xT GP460xT Touch Screen Operator Interface 12.1 TFT Analog Color LCD

More information

Preface. Corresponding units: PS-3700A Series units (All product names that appear in this guide are the trademarks of their respective

Preface. Corresponding units: PS-3700A Series units (All product names that appear in this guide are the trademarks of their respective Preface The PSA-HD20 is made by Pro-face for use with PS-3700A Series (hereafter referred as the "PS-A") units. This 2.5 inch 20GB hard disk is designed to be installed inside the PS-A unit. Corresponding

More information

WARNINGS. *1 This mark is applicable only in Taiwan.

WARNINGS. *1 This mark is applicable only in Taiwan. WARNINGS When connecting the GP37W2-BG41-24V(hereafter referred to as the "GP")'s power cord terminals to the power terminal block, check first that the GP power supply is completely turned OFF, via a

More information

Preface NOTICE. 2. The information contained in this manual is subject to change without notice.

Preface NOTICE. 2. The information contained in this manual is subject to change without notice. Preface Thank you for purchasing Pro-face s the Hybrid Terminal Block. The Hybrid Terminal Block (Hereafter referred to as the "HTB") network interface module with built-in Inputs/Outputs is small in size.

More information

Preface NOTICE. 2. The information contained in this manual is subject to change without notice.

Preface NOTICE. 2. The information contained in this manual is subject to change without notice. Preface Thank you for purchasing Pro-face s the Hybrid Terminal Block. The Hybrid Terminal Block (Hereafter referred to as the "HTB") network interface module with built-in Inputs/Outputs is small in size.

More information

PS-3710A Series. Hardware Manual

PS-3710A Series. Hardware Manual PS-3710A Series Hardware Manual Preface Thank you for purchasing Pro-face s PS-3710A Series (Hereafter referred to as the PS-A unit ). Before operating your PS-A unit, be sure to read this manual to familiarize

More information

GP3000H Conversion Adapter Installation Guide. Package Contents. Safety Cautions. About the Manual. Unit Disposal. To Prevent Accidents

GP3000H Conversion Adapter Installation Guide. Package Contents. Safety Cautions. About the Manual. Unit Disposal. To Prevent Accidents GP3000H Conversion Installation Guide Thank you for purchasing Pro-face s GP3000H Conversion (Hereafter referred to as this adapter ). This adapter converts the cable connector on the GP3000H Series to

More information

OpenHMI IWS Operator Interface Products

OpenHMI IWS Operator Interface Products OpenHMI IWS Operator Interface Products FEATURES Microsoft Windows -based development and runtime software 7.4 to 15 color flat panel display Operator input through a combination of integrated touchscreen,

More information

PS-3650A /PS-3651A. User Manual

PS-3650A /PS-3651A. User Manual PS-3650A /PS-3651A User Manual Preface Thank you very much for purchasing a Pro-face PS-3650A/PS-3651A Unit, hereafter referred to as the PS-A. Before using the PS-A, read this manual thoroughly to familiarize

More information

WARNING. To Prevent From Damage:

WARNING. To Prevent From Damage: WARNING When connecting a power cable to the GP unit, be sure the cable has been unplugged from the power outlet, so that you would not get an electric shock. High voltage runs in the GP unit, so if you

More information

UL/c-UL(CSA) Approval

UL/c-UL(CSA) Approval GP2000H Series RS-422 Conversion Adapter (GP2000H-AP422) Installation Guide Thank you for purchasing Pro-face's GP2000H Series RS-422 type Conversion Adapter, hereafter referred to as the "Adapter" Using

More information

Surge Protective Devices. Installation & Operation Manual. Model 335

Surge Protective Devices. Installation & Operation Manual. Model 335 Surge Protective Devices Installation & Operation Manual Model 335 CALIFORNIA CUSTOMERS - PROP 65 WARNING WARNING: This product can expose you to chemicals including DINP, which is known to the State of

More information

WARNINGS. FP3700-T41 Installation Guide

WARNINGS. FP3700-T41 Installation Guide FP3700-T41 Installation Guide WARNINGS When connecting the FP3700-T41 (hereafter referred to as the "FP")'s power cord terminals to the FP unit's Terminal Block, check first that the FP unit's power supply

More information

PL-HD220 Installation Guide

PL-HD220 Installation Guide PL-HD220 Installation Guide This hard disk drive unit is made by Pro-face for use with its panel-type computers, hereafter referred to as the "PL". This 2.5 inch 20GB hard disk is designed to be installed

More information

UL/c-UL(CSA) Approval

UL/c-UL(CSA) Approval GP2000H Series RS-232C Conversion Adapter (GP2000H-AP232) Installation Guide Thank you for purchasing Pro-face's GP2000H Series RS-232C type Conversion Adapter, hereafter referred to as the "Adapter" Using

More information

FP-3710K Series Installation Guide. Package Contents. UL/c-UL/CSA Approval. Required software/reference manual

FP-3710K Series Installation Guide. Package Contents. UL/c-UL/CSA Approval. Required software/reference manual FP-3710K Series Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. Package Contents FP unit (1) Installation Guide (1) (this manual)

More information

Safety Precautions. Danger. Flex Network I/O Unit 32-point Input Sink Source / 32-point Transistor Output Sink Type Installation Guide.

Safety Precautions. Danger. Flex Network I/O Unit 32-point Input Sink Source / 32-point Transistor Output Sink Type Installation Guide. Flex Network I/O Unit 32-point Input Sink Source / 32-point Transistor Output Sink Type Installation Guide Thank you for purchasing Pro-face's "Flex Network I/O Unit 32-point Input Sink Source / 32-point

More information

Preface NOTICE Copyright Digital Electronics Corporation. All rights reserved.

Preface NOTICE Copyright Digital Electronics Corporation. All rights reserved. Preface Thank you for purchasing Pro-face s PS-3710A/PS-3711A Series (Hereafter referred to as the PS-A unit ). Before operating your PS-A unit, be sure to read this manual to familiarize yourself with

More information

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide Thank you for purchasing Pro-Face's Rear Cover. This Rear Cover can be attached to the following products: PS-600G Series, PS-500P

More information

1. Essential Safety Precautions

1. Essential Safety Precautions Thank you for purchasing the CANopen Master Unit (hereafter referred to as this unit ) for the Pro-face s LT3000 Series. This is an expansion unit intended to add Pro-face's LT3000 Series Graphic Logic

More information

PFXGP4601TAA. Pro-face Xycom GP4000 PFXGP4601TAA

PFXGP4601TAA.   Pro-face Xycom GP4000 PFXGP4601TAA PFXGP4601TAA http://www.axcontrol.com/automation/pro-face/gp-4000/pfxgp4601taa Pro-face Xycom GP4000 PFXGP4601TAA Pro-face Xycom GP-460xT GP460xT Touch Screen Operator Interface 12.1 TFT Analog Color LCD

More information

WARNING. To Prevent From Damage:

WARNING. To Prevent From Damage: WARNING When connecting a power cable to the GP unit, be sure the cable has been unplugged from the power outlet, so that you would not get an electric shock. When replacing the backlight, be sure to turn

More information

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series. Preface Thank you for purchasing the DeviceNet Slave unit CA6-DNSALL/EX-01 (hereafter referred to as the DeviceNet unit ). This unit is intended for use with expansion interface of the Pro-face s GP3000

More information

Essential Safety Precautions WARNINGS

Essential Safety Precautions WARNINGS Essential Safety Precautions WARNINGS System Design Do not create GP touch panel switches that could possibly endanger the safety of equipment and personnel. Damage to the GP, its I/O unit(s), cable(s),

More information

UL/c-UL(CSA) Application Notes

UL/c-UL(CSA) Application Notes WARNINGS System Design Do not create ST touch panel switches that could possibly endanger the safety of equipment and personnel. Damage to the ST, its I/O unit(s), cable(s), and other related equipment

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide CONTEC CO.,LTD. Thank you for purchasing the PPC-HDD(MS)A hard disk unit for PC CPU Module. instructions in this

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input Product datasheet Characteristics TM241C24R Complementary Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Discrete input logic Discrete input voltage Discrete

More information

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box Product datasheet Characteristics TM7BDI16B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 16 Input/output number of

More information

Surge Protective Devices. Installation & Operation Manual. Model 420

Surge Protective Devices. Installation & Operation Manual. Model 420 Surge Protective Devices Installation & Operation Manual Model 420 CALIFORNIA CUSTOMERS - PROP 65 WARNING WARNING: This product can expose you to chemicals including DINP, which is known to the State of

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

Appendix G. CJ1W-CIF11 RS-422A Converter

Appendix G. CJ1W-CIF11 RS-422A Converter CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

DANGERS When Designing your GLC System: WARNINGS Wiring Warnings:

DANGERS When Designing your GLC System: WARNINGS Wiring Warnings: DANGERS When Designing your GLC System: - Be sure to design your GLC control system so that in the event of a main power supply failure or a GLC accident, the user system s overall safety integrity will

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

Wall Mount Adaptor Installation Guide (CA1-WMALRG-01)

Wall Mount Adaptor Installation Guide (CA1-WMALRG-01) Wall Mount Adaptor Installation Guide (CA1-WMALRG-01) Thank you for purchasing Pro-Face's Wall Mount Adaptor. This adaptor can be attached to the following products: PS-600G Series, PS-500P Series, GP-2500/2600

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Product availability : Stock - Normally stocked in distribution facility Price* : 519.00 USD Main Range of product Product or component type [Us] rated supply

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

MT8050iE series. Installation Instruction (1) (2)

MT8050iE series. Installation Instruction (1) (2) MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Touch Operator Interface GP4000SERIES.

Touch Operator Interface GP4000SERIES. Touch Operator Interface GP4000SERIES www.proface.com GP4000 SERIES L i n e up Standard Model 12.1" 10.4" Color variation Color variation 7.5" AC 100-240V DC 24V AC 100-240V DC 24V DC 24V DC 24V DC 24V

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and

More information