MULTI meter MU 6100 H

Size: px
Start display at page:

Download "MULTI meter MU 6100 H"

Transcription

1 MULTI meter INSTRUCTION MANUAL European Catalogue Number(s): S1: S2: Version: 2 Issued: September 11, :39 am ba77077e02 09/2014

2 Legal address of manufacturer: VWR International bvba Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven Manufactured in Germany. 2 ba77077e02 09/2014

3 Contents - Contents 1 Safety Safety information Safety information in the operating manual Safety signs on the meter Further documents providing safety information Safe operation Authorized use Requirements for safe operation Unauthorized use Overview meter Sensors Technical data Measuring ranges, resolution, accuracy ph/orp Oxi Cond General data Commissioning Scope of delivery Power supply Initial commissioning Inserting the batteries Operation General operating principles Keypad Display Status information (meter) Connectors Switching on the meter Switching off Navigation Operating modes Measured value display Menus and dialogs ba77077e02 09/2014 3

4 Contents Elements in menus and dialogs Navigation example 1:Setting the language Example 2 on navigation: Setting the date and time Channel display Display of several sensors in the measuring mode ph value Measuring Measuring the ph value Measuring the temperature Calibration Why calibrate? When do you have to calibrate? Automatic calibration (AutoCal) Manual calibration (AnyCal) Calibration points Calibration data ORP voltage Measuring Measuring the ORP Measuring the temperature ORP calibration Dissolved oxygen Measuring Measuring D.O Measuring the temperature Calibration Why calibrate? When to calibrate? Calibration procedure Calibration in water vapor-saturated air (air calibration vessel) Calibrating with a comparison measurement (OxiComp) Calibration data Conductivity Measuring Measuring the conductivity Measuring the temperature Calibration Why calibrate? ba77077e02 09/2014

5 Contents When to calibrate? Determining the cell constant (calibration in control standard) Calibration data Settings Measurement settings Settings for ph measurements Buffer sets for calibration Calibration interval Settings for ORP measurements Settings for D.O. sensors Calibration interval Settings for conductivity measuring cells Calibration interval Temperature compensation Setting the TDS factor Sensor-independent settings System Data storage Automatic Stability control Reset Resetting the measurement settings Resetting the system settings Data memory Manual storage Automatic data storage at intervals Measurement data memory Editing the measurement data memory Erasing the measurement data memory Measurement dataset Memory locations Transmitting data (USB interface) Options for data transmission Connecting a PC MultiLab Importer Maintenance, cleaning, disposal, accessories Maintenance General maintenance activities Replacing the batteries Cleaning Packing Disposal ba77077e02 09/2014 5

6 Contents 13.5 Accessories General information ph / ORP Conductivity D.O What to do if ph/orp Dissolved oxygen Conductivity General information Firmware update Glossary Index Technical service Warranty Compliance with local laws and regulations ba77077e02 09/2014

7 Safety 1 Safety 1.1 Safety information Safety information in the operating manual This operating manual provides important information on the safe operation of the meter. Read this operating manual thoroughly and make yourself familiar with the meter before putting it into operation or working with it. The operating manual must be kept in the vicinity of the meter so you can always find the information you need. Important safety instructions are highlighted in this operating manual. They are indicated by the warning symbol (triangle) in the left column. The signal word (e.g. "CAUTION") indicates the level of danger: WARNING indicates a possibly dangerous situation that can lead to serious (irreversible) injury or death if the safety instruction is not followed. CAUTION indicates a possibly dangerous situation that can lead to slight (reversible) injury if the safety instruction is not followed. NOTE indicates a possibly dangerous situation where goods might be damaged if the actions mentioned are not taken Safety signs on the meter Note all labels, information signs and safety symbols on the meter and in the battery compartment. A warning symbol (triangle) without text refers to safety information in this operating manual Further documents providing safety information The following documents provide additional information, which you should observe for your safety when working with the measuring system: Operating manuals of sensors and other accessories Safety datasheets of calibration or maintenance accessories (such as buffer solutions, electrolyte solutions, etc.) ba77077e02 09/2014 7

8 Safety 1.2 Safe operation Authorized use This meter is authorized exclusively for ph, ISE, ORP, dissolved oxygen and conductivity measurements in a field and laboratory environment. Only the operation and running of the meter according to the instructions and technical specifications given in this operating manual is authorized (see section 3 TECHNICAL DATA, page 10). Any other use is considered unauthorized Requirements for safe operation Note the following points for safe operation: The meter may only be operated according to the authorized use specified above. The meter may only be supplied with power by the energy sources mentioned in this operating manual. The meter may only be operated under the environmental conditions mentioned in this operating manual. The meter may only be opened if this is explicitly described in this operating manual (example: Inserting the batteries) Unauthorized use The meter must not be put into operation if: it is visibly damaged (e.g. after being transported) it was stored under adverse conditions for a lengthy period of time (storing conditions, see section 3 TECHNICAL DATA, page 10). 8 ba77077e02 09/2014

9 Overview 2 Overview 2.1 meter The meter enables you to perform measurements (ph, U, conductivity, dissolved oxygen) ) quickly and reliably. The provides the maximum degree of operating comfort, reliability and measuring certainty for all applications Keypad 2 Display 3 Connectors 2.2 Sensors A measuring system ready to measure consists of the meter and a suitable sensor. Suitable sensors are ph electrodes, ORP electrodes, D.O. sensors and conductivity measuring cells. ba77077e02 09/2014 9

10 Technical data 3 Technical data 3.1 Measuring ranges, resolution, accuracy ph/orp Measuring ranges, resolution Manual temperature input Variable Measuring range Resolution ph U [mv] T [ C] T [ F] Variable Range Increment T manual [ C] T manual [ F] Accuracy (± 1 digit) Variable Accuracy Temperature of the test sample ph / range * ± C C ± C C ± C C U [mv] / range ± C C ± C C T [ C] / temperature sensor NTC 30 ± 0.1 PT 1000 ± 0.1 * when measuring in a range of ± 2 ph around a calibration point The accuracy values specified here apply exclusively to the meter. The accuracy of the electrodes and buffer solutions has to be taken into account additionally. 10 ba77077e02 09/2014

11 Technical data Oxi Measuring ranges, resolution (depending on the sensor) Variable Measuring range Resolution Concentration [mg/l] ( ) ( ) Saturation [%] ( ) D.O. partial pressure [mbar] ( ) (0.1) 0.1 (1) 0.1 (1) (1) 1 T [ C] ,0 0.1 Accuracy (± 1 digit) Variable Accuracy Concentration [mg/l] ± 0.5 % of measured value at ambient temperature of +5 C C Saturation [%] ± 0.5% of measured value when measuring in the range of ± 10 K around the calibration temperature D.O. partial pressure [mbar] T [ C] / temperature sensor NTC 30 ± 0.1 PT 1000 ± 0.1 ± 0.5 % of measured value at ambient temperature of +5 C C Correction functions Temperature compensation Salinity correction Air pressure correction Accuracy better than 2 % at C SAL Automatic through integrated pressure sensor in the range of mbar The accuracy values specified here apply exclusively to the meter. The accuracy of the D.O. sensors has also to be taken into account. ba77077e02 09/

12 Technical data Cond Measuring ranges, resolution (depending on the sensor) Variable Measuring range Resolution ϰ[µs/cm] * ** ϰ [ms/cm] ρ (Resistivity) [Ohm*cm] ρ (Resistivity) [kohm*cm] ρ (Resistivity) [MOhm*cm] ** * SAL according to the IOT table TDS mg/l g/l g/l T [ C] T [ F] * only possible with cells of the cell constant, cm-1 ** only possible with cells of the cell constant, cm -1 or cm -1 Cell constants Cell constant C Values Can be calibrated in the ranges cm cm -1 Adjustable cm cm -1 (fixed) 0, ,000 cm -1 Reference temperature Reference temperature Adjustable Values 20 C (Tref20) 25 C (Tref25) 12 ba77077e02 09/2014

13 Technical data Accuracy (± 1 digit) Variable Accuracy Temperature of the test sample ϰ and ρ / temperature compensation None (Off) ± 0.5 % Nonlinear (nlf) ± 0.5 % 0 C C according to EN ± 0.5 % +35 C C enhanced nlf function Linear (lin) ± 0.5 % +10 C C SAL / range ± C C TDS [mg/l] ± C C ± 0.5 % T [ C] / temperature sensor NTC 30 ± 0.1 PT 1000 ± 0.1 The accuracy values specified here apply exclusively to the meter. The accuracy of the measuring cell has also to be taken into account. Further data are given in the documentation of your sensor. 3.2 General data Dimensions ca. 180 x 80 x 55 mm Weight Approx. 0.4 kg Mechanical structure Type of protection IP 67 Electrical safety Protective class III Test certificates CE Ambient conditions Storage -25 C C Operation +5 C C Admissible relative humidity Yearly mean: < 75 % 30 days/year: 95 % Other days: 85 % ba77077e02 09/

14 Technical data Power supply Batteries Rechargeable batteries Operational life 4 x 1.5 V alkali-manganese batteries, type AA 4 x 1.2 V NiMH rechargeable batteries, type AA (no charging function) Up to 1000 h without / 150 h with illumination ph sensor input Input resistance > 5 * ohm Input current < 1 * A USB interface Type USB 1.1 USB B (device), data output Baud rate Adjustable: 1200, 2400, 4800, 9600, Baud Data bits 8 Stop bits 2 Parity None Handshake RTS/CTS Cable length Max. 3 m Guidelines and norms used EMC EC directive 2004/108/EC EN EN EN FCC Class A Meter safety EC directive 2006/95/EC EN UL CAN/CSA-C22.2# IP protection class EN ba77077e02 09/2014

15 Commissioning 4 Commissioning 4.1 Scope of delivery Meter 4 batteries 1.5 V Mignon type AA Short instructions CD-ROM with USB drivers detailed operating manual Software MultiLab Importer 4.2 Power supply The is supplied with power in the following ways: Battery operation (4 x alkaline manganese batteries, type AA) USB operation via a connected USB-B cable 4.3 Initial commissioning Perform the following activities: Insert the supplied batteries Switch on the meter (see section 5.2 SWITCHING ON THE METER, page 19) Set the date and time (see section EXAMPLE 2 ON NAVIGATION: SETTING THE DATE AND TIME, page 24) ba77077e02 09/

16 Commissioning Inserting the batteries Screws 2 Battery compartment CAUTION Make sure that the poles of the batteries are positioned correctly. The ± signs on the batteries must correspond to the ± signs in the battery compartment. You can operate the meter either with normal batteries or with rechargeable batteries (Ni-MH). In order to charge the batteries, an external charging device is required. 1. Place four batteries (type Mignon AA) in the battery compartment. 2. Close the battery compartment. 3. Set the date and time (see section EXAMPLE 2 ON NAVIGATION: SETTING THE DATE AND TIME, page 24). 16 ba77077e02 09/2014

17 Operation 5 Operation 5.1 General operating principles Keypad In this operating manual, keys are indicated by brackets <..>. The key symbol (e.g. <OK>) generally indicates a short keystroke (under 2 sec) in this operating manual. A long keystroke (approx. 2 sec) is indicated by the underscore behind the key symbol (e.g. <OK_>). <F1>: <F1_>: <F2>: <F2_>: <On/Off>: <MODE>: Softkeys providing situation dependent functions, e.g.: <F2>/[USB output]: Outputs data to the USB interface <F2_>/[USB output]: Configures the automatic data output to the USB interface Switches the meter on or off Selects the measured parameter / Quits the settings <CAL>: <CAL_>: <STR>: <STR_>: <RCL>: <RCL_>: < >< >: < _>< _>: <OK>: <OK_>: <HOLD> Calls up the calibration procedure Displays the calibration data Saves a measured value manually Opens the menu for the automatic save function Displays the manually stored measured values Displays the automatically stored measured values Menu control, navigation Increments, decrements values Increments, decrements values continuously Opens the menu for measurement settings / confirms entries Opens the menu for system settings Freezes the measured value (HOLD function) ba77077e02 09/

18 Operation Display 3 ph 2 1 AutoCal TEC HOLD AR Menu : C Status information (sensor) 2 Measured value (with unit) 3 Measured parameter 4 Channel display: Plug position of the sensor 5 Sensor symbol (calibration evaluation, calibration interval) 6 Measured temperature (with unit) 7 Status information (meter) 8 Softkeys and date + time Status information (meter) AR HOLD Stability control (AutoRead) is active (calibration) Measured value is frozen (<HOLD> key) Batteries are almost empty Data are automatically output to the USB-B interface at intervals 18 ba77077e02 09/2014

19 Operation Connectors ph electrode 2 Temperature sensor 3 D.O. sensor or conductivity measuring cell 4 Mini USB-B interface 5 Service interface CAUTION Only connect sensors to the meter that cannot return any voltages or currents that are not allowed (> SELV and > current circuit with current limiting). Almost all customary sensors fulfill these conditions. 5.2 Switching on the meter 1. Switch the meter on with <On/Off>. The meter performs a self-test. The display shows the manufacturer's logo while the self-test is being performed. The measured value display appears. ph C Menu :15 ba77077e02 09/

20 Operation 5.3 Switching off 1. Switch the printer off with <On/Off>. Automatic shut-off function The instrument has an automatic shut-off function in order to save the batteries (see section SYSTEM, page 62). The automatic shut-off function switches off the meter if no key is pressed for an adjustable period. The automatic shut-off function is not active if the communication cable is connected if the Automatic data storage function is active, or with automatic data transmission Display illumination The meter automatically switches off the display illumination if no key is pressed for 30 seconds. The illumination is switched on with the next keystroke again. You can also generally switch the display illumination on or off (see section SYSTEM, page 62). 5.4 Navigation The principles of navigation in menus and dialogs are explained in the following sections Operating modes The instrument has the following operating modes: Operating mode Measuring Calibration Storing in memory Transmitting data Setting Explanation The measurement data of the connected sensor are shown in the measured value display The course of a calibration with calibration information, functions and settings is displayed The meter stores measuring data automatically or manually The meter transmits measuring data and calibration records to a USB-B interface automatically or manually. The system menu or a sensor menu with submenus, settings and functions is displayed Only those displays and functions are available in the active operating mode that are currently being required. 20 ba77077e02 09/2014

21 Operation Measured value display In the measured value display, open the setting menus with <OK>. The current functions of the softkeys are shown on the display. Use <OK> (short pressure) to open the menu for calibration and measurement settings for the displayed measured parameter. Use <OK_> (long keystroke (approx. 2 s) to open the Storage & config menu with the sensor-independent settings. Use the keys of the keypad to carry out further functions such as storage or calibration (see section KEYPAD, page 17). These functions are not available in other operating situations Menus and dialogs The menus for settings and dialogs in procedures contain further subelements. To select a subelement, use the < >< > keys. The current selection is displayed with a frame. To make further settings, switch to the next higher menu level with <F1>[Back]. Use <MODE> to return to the measured value display Elements in menus and dialogs Submenus The name of the submenu is displayed at the upper edge of the frame. Submenus are opened by confirming with <OK>. Example: System General Interface Clock Service information Reset Back :15 Settings Settings are indicated by a colon. The current setting is displayed on the right-hand side. The setting mode is opened with <OK>. Subsequently, the setting can be changed with < >< > and <OK>. Example: ba77077e02 09/

22 Operation General Language: Deutsch Beep: Off Illumination: On Contrast: 50 % Switchoff time: 1 h Temperature unit: C Stability control: On Back :15 Functions Functions are designated by the name of the function. They are immediately carried out by confirming with <OK>. Example: Display the Calibration record function. ph Calibration record Calibration data storage Buffer: One point calibration: Calibration interval: Unit for slope: TEC Yes 7 d mv/ph i (20 C) Back 14:15 Messages Information is marked by the i symbol. It cannot be selected. Example: ph Calibration record Calibration data storage Buffer: One point calibration: Calibration interval: Unit for slope: TEC Yes 7 d mv/ph i (20 C) Back 14: Navigation example 1:Setting the language 1. Press the <On/Off> key. The measured value display appears. The instrument is in the measuring mode. 22 ba77077e02 09/2014

23 Operation ph C Menu :15 2. Open the Storage & config menu with <OK_>. The instrument is in the setting mode. Storage & config System Data storage Back :15 3. Select the System submenu with < >< >. The current selection is displayed with a frame. 4. Open the System submenu with <OK>. System General Interface Clock Service information Reset Back :15 5. Select the General submenu with < >< >. The current selection is displayed with a frame. 6. Open the General submenu with <OK>. ba77077e02 09/

24 Operation General Language: Deutsch Beep: Off Illumination: On Contrast: 50 % Switchoff time: 1 h Temperature unit: C Stability control: On Back :15 7. Open the setting mode for the Language with <OK>. General Language: Deutsch Beep: Off Illumination: On Contrast: 50 % Switchoff time: 1 h Temperature unit: C Stability control: On Back :15 8. Select the required language with < >< >. 9. Confirm the setting with <OK>. The meter switches to the measuring mode. The selected language is active Example 2 on navigation: Setting the date and time The meter has a clock with a date function. The date and time are shown in the measured value display. When storing measured values and calibrating, the current date and time are automatically stored as well. The correct setting of the date and time and date format is important for the following functions and displays: Current date and time Calibration date Identification of stored measured values. Therefore, check the time at regular intervals. After a fall of the supply voltage (empty batteries), the date and time are reset. 24 ba77077e02 09/2014

25 Operation The date format can be switched from the display of day, month, year (dd.mm.yyyy) to the display of month, day, year (mm/dd/yyyy or mm.dd.yyyy). 1. In the measured value display: Open the Storage & config menu with <OK_>. The instrument is in the setting mode. 2. Select and confirm the System / Clock menu with < >< > and <OK>. The setting menu for the date and time opens up. 3. Select and confirm the Time menu with < >< > and <OK>. The hours are highlighted. Clock Date format: dd.mm.yyyy Date: Time: 14:15:25 Back :15 4. Change and confirm the setting with < >< > and <OK>. The minutes are highlighted. 5. Change and confirm the setting with < >< > and <OK>. The seconds are highlighted. 6. Change and confirm the setting with < >< > and <OK>. The time is set. 7. If necessary, set the Date and Date format. The setting is made similarly to that of the time. 8. To make further settings, switch to the next higher menu level with [Back]<F1>. or Switch to the measured value display with <MODE>. The instrument is in the measuring mode. ba77077e02 09/

26 Operation 5.5 Channel display The manages the connected sensors and displays which sensor is plugged to which connection. ph C Channel display Display of the plug position for the respective parameter The filled bar indicates for each connected sensor to which plug position of the meter it is connected :15 USB output Display of several sensors in the measuring mode The measured values of the connected sensors can be displayed in the following ways: Clear display of all connected sensors Detailed display of one sensor With the softkey you can very easily switch between the two display types. The suitable softkey is displayed depending on the operating situation. ph C ϰ /cm 25.0 C ph C :15 USB output :15 USB output 26 ba77077e02 09/2014

27 ph value 6 ph value 6.1 Measuring Measuring the ph value NOTE When connecting an grounded PC/printer, measurements cannot be performed in grounded media as the values would be incorrect. The USB interface is not galvanically isolated. To ensure the high measurement accuracy of the measuring system, always measure with a calibrated electrode (see section 6.2 CALIBRATION, page 29). 1. Connect the ph electrode to the meter. 2. If necessary, select the measured parameter with <MODE>. 3. When measuring without temperature sensor: Temper the test sample, or measure the current temperature. Enter the temperature value in the menu. 4. Immerse the ph electrode in the test sample. The measured value is checked for stability (automatic stability control). The display of the measured parameter flashes. 5. Wait for a stable measured value. The display of the measured parameter no longer flashes. ph C Menu :15 Stability control (AutoRead ) Criteria for a stable measured value The stability control function (AutoRead) continually checks the stability of the measurement signal. The stability has a considerable impact on the reproducibility of measured values (see section AUTOMATIC STABILITY CONTROL, page 63). The Stability control function checks whether the measured values are stable ba77077e02 09/

28 ph value within the monitored time interval. Measured parameter Time interval Stability in the time interval ph value 15 seconds Δ : better than 0.01 ph Temperature 15 seconds Δ : better than 0.5 C The minimum duration until a measured value is assessed as stable is the monitored time interval. The actual duration is mostly longer. Freezes the measured value (HOLD function) With the HOLD function, you can freeze the current measured value. The displayed measured value stops changing until you switch the HOLD function off. 1. Freeze the measured value with <HOLD>. The [HOLD] status indicator is displayed. 2. Release the frozen measured value again with <HOLD>. The HOLD function is switched off. The [HOLD] status display disappears Measuring the temperature For reproducible ph measurements, it is essential to measure the temperature of the test sample. You have the following options to measure the temperature: Automatic measurement of the temperature with the temperature sensor (NTC30 or Pt1000) integrated in the sensor. Measurement by an external temperature sensor. Manual determination and input of the temperature. The measuring instrument recognizes whether a suitable sensor is connected and automatically switches on the temperature measurement. The display of the temperature indicates the active temperature measuring mode: Temperature sensor Resolution of the temp. display Temp. measurement yes 0.1 C Automatic with temperature sensor - 1 C Manual If you wish to measure (or calibrate) without temperature sensor, proceed as follows: 1. Measure the current temperature of the test sample. 2. In the <OK>/pH/Man. temperature menu, set the temperature value with < >< >. 28 ba77077e02 09/2014

29 ph value 6.2 Calibration Why calibrate? ph electrodes age. This changes the zero point (asymmetry) and slope of the ph electrode. As a result, an inexact measured value is displayed. Calibration determines and stores the current values of the zero point and slope of the electrode. Thus, you should calibrate at regular intervals When do you have to calibrate? After connecting a sensor Routinely within the framework of the company quality assurance When the calibration interval has expired Automatic calibration (AutoCal) Make sure that in the sensor menu, Buffer menu, the buffer set is correctly selected (see SETTINGS FOR PH MEASUREMENTS, PAGE 52). Use any one to five buffer solutions of the selected buffer set in ascending or descending order. Below, calibration with Technical buffers (TEC) is described. When other buffer sets are used, other nominal buffer values are displayed. Apart from that, the procedure is identical. If single-point calibration was set in the menu, the calibration procedure is automatically finished with the measurement of buffer solution 1 and the calibration record is displayed. 1. Connect the ph electrode to the meter. 2. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 3. In the measured value display, select the measured parameter ph or mv with <MODE>. 4. Start the calibration with <CAL>. The calibration display for the first buffer appears (voltage display). ba77077e02 09/

30 ph value ph Buffer 1 AutoCal TEC C mv :15 5. Thoroughly rinse the electrode with deionized water. 6. Immerse the electrode in the first buffer solution. 7. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 8. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. ph AutoCal TEC AR Buffer C : mv 9. Wait for the end of the measurement with stability control or accept the calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 10. If necessary, finish the calibration procedure as a single-point calibration with <MODE>. The calibration record is displayed. For single-point calibration, the instrument uses the Nernst slope (-59.2 mv/ph at 25 C) and determines the zero point of the electrode. Continuing with twopoint calibration 11. Thoroughly rinse the electrode with deionized water. 12. Immerse the electrode in the second buffer solution. 30 ba77077e02 09/2014

31 ph value 13. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 14. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. ph Buffer mv 24.8 C AutoCal TEC AR : Wait for the measurement with stability control to be completed or terminate the stability control and take over the calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 16. If necessary, finish the calibration procedure as a two-point calibration with <MODE>. The calibration record is displayed. Continuing with three- to five-point calibration 17. Thoroughly rinse the electrode with deionized water. 18. Immerse the electrode in the next buffer solution. 19. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 20. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. ph AutoCal TEC AR Buffer C mv :15 ba77077e02 09/

32 ph value 21. Wait for the measurement with stability control to be completed or terminate the stability control and take over the calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 22. If necessary, use <MODE> to finish calibration or Continue calibrating using the next buffer with <OK>. Calibration is automatically completed after the last buffer of a buffer set has been measured. Then the calibration record is displayed. The calibration line is determined by linear regression Manual calibration (AnyCal) Make sure that in the sensor menu, Buffer menu, the AnyCal buffer set is correctly selected (see section SETTINGS FOR PH MEASUREMENTS, page 52). Use any one to five buffer solutions in ascending or descending order. If single-point calibration was set in the menu, the calibration procedure is automatically finished with the measurement of buffer solution 1 and the calibration record is displayed. 1. Connect the ph electrode to the meter. The ph measuring window is displayed. 2. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 3. In the measured value display, select the measured parameter ph or mv with <MODE>. 4. Start the calibration with <CAL>. The calibration display appears (voltage display). ph AnyCal Buffer C mv :15 5. Thoroughly rinse the electrode with deionized water. 6. Immerse the electrode in the first buffer solution. 32 ba77077e02 09/2014

33 ph value 7. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 8. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. ph Buffer C mv AnyCal AR :15 9. Wait for the end of the measurement with stability control or accept the calibration value with <OK>. The calibration display for the setting of the nominal buffer value appears. ph AnyCal Buffer C : Set the nominal buffer value for the measured temperature with < >< >. 11. Accept the set calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 12. If necessary, finish the calibration procedure as a single-point calibration with <MODE>. The calibration record is displayed. For single-point calibration, the instrument uses the Nernst slope (-59.2 mv/ph at 25 C) and determines the zero point of the electrode. Continuing with twopoint calibration 13. Thoroughly rinse the electrode with deionized water. ba77077e02 09/

34 ph value 14. Immerse the electrode in the second buffer solution. 15. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 16. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. 17. Wait for the measurement with stability control to be completed or terminate the stability control and take over the calibration value with <OK>. The calibration display for the setting of the nominal buffer value appears. ph AnyCal Buffer C : Set the nominal buffer value for the measured temperature with < >< >. 19. Accept the set calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 20. Finish the calibration procedure as a two-point calibration with <MODE>. The calibration record is displayed. Continuing with three- to five-point calibration 21. Thoroughly rinse the electrode with deionized water. 22. Immerse the electrode in the next buffer solution. 23. When measuring without temperature sensor: Temper the buffer solution, or measure the current temperature. Enter the temperature value in the menu. 24. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. 25. Wait for the measurement with stability control to be completed or terminate the stability control and take over the calibration value with <OK>. The calibration display for the setting of the nominal buffer value appears. 34 ba77077e02 09/2014

35 ph value ph AnyCal Buffer C : Set the nominal buffer value for the measured temperature with < >< >. 27. Accept the set calibration value with <OK>. The calibration display for the next buffer appears (voltage display). 28. Use <MODE> to finish calibration or Continue calibrating using the next buffer with <OK>. After the fifth buffer has been measured the calibration is automatically finished. Then the calibration record is displayed. The calibration line is determined by linear regression Calibration points Calibration can be performed using one to five buffer solutions in any order (single-point to five-point calibration). The meter determines the following values and calculates the calibration line as follows: Determined values Displayed calibration data 1-point Asy Zero point = Asy Slope = Nernst slope (-59.2 mv/ph at 25 C) 2-point 3-point to 5-point Asy Slp. Asy Slp. Zero point = Asy Slope = Slp. Zero point = Asy Slope = Slp. The calibration line is calculated by linear regression. You can display the slope in the units, mv/ph or % (see section SETTINGS FOR PH MEASUREMENTS, page 52). ba77077e02 09/

36 ph value Calibration data The calibration record is automatically transmitted to the interface after calibrating. Displays the calibration data Displaying the calibration data memory The calibration record of the last calibration is to be found under the menu item, <OK> / Calibration / Calibration record. To open it, press the <CAL_> key in the measured value display. Subsequently, you can transmit the displayed calibration data to the interface, e.g. to a PC, with the <F2>/[USB output] key. The calibration records of the last calibrations are to be found in the menu, <OK> / Calibration / Calibration data storage. Menu item Calibration / Calibration data storage / Display Calibration / Calibration data storage / Output to USB Setting/ function Explanation - Displays the calibration record. Further options: Scroll through the calibration records with < >< >. Output the displayed calibration record to the interface with <F2>/[USB output]. Quit the display with <F1>/ [Back] or <OK>. Switch directly to the measured value display with <MODE>. - Outputs the calibration records to the interface. Calibration evaluation After calibrating, the meter automatically evaluates the calibration. The zero point and slope are evaluated separately. The worse evaluation of both is taken into account. The evaluation appears on the display and in the calibration 36 ba77077e02 09/2014

37 ph value record. Display Calibration record Zero point [mv] Slope [mv/ ph] <-15 or > <-20 or > <-25 or > > <-60.5 or > <-61.0 or > Clean the electrode according to the electrode operating manual Error Error <-30 oder >+30 <-62.0 oder >-50.0 Error elimination (see section 14 WHAT TO DO IF..., page 79) Calibration record (example) Ser. no CALIBRATIONpH :55 AutoCal TEC Buffer Buffer Buffer Voltage mv Voltage mv Voltage mv Temperature C Temperature C Temperature C Slope mv/ph Asymmetry 4.0 mv Sensor +++ etc... ba77077e02 09/

38 ORP voltage 7 ORP voltage 7.1 Measuring Measuring the ORP NOTE When connecting an grounded PC/printer, measurements cannot be performed in grounded media as the values would be incorrect. The USB interface is not galvanically isolated. 1. Connect the ORP electrode to the meter. 2. If necessary, select the U (mv) display with <MODE>. 3. When measuring without temperature sensor: Temper the test sample, or measure the current temperature. Enter the temperature value in the menu. 4. Rinse the ORP electrode and immerse it in the test sample. The measured value is checked for stability (automatic stability control). The display of the measured parameter flashes. 5. Wait for a stable measured value. The display of the measured parameter no longer flashes. U mv 24.8 C Menu :15 Stability control (AutoRead ) Criteria for a stable measured value The stability control function (AutoRead) continually checks the stability of the measurement signal. The stability has a considerable impact on the reproducibility of measured values (see section AUTOMATIC STABILITY CONTROL, page 63). The Stability control function checks whether the measured values are stable within the monitored time interval. Measured parameter Time interval Stability in the time interval ORP 15 seconds Δ : better than 0.3 mv Temperature 15 seconds Δ : better than 0.5 C The minimum duration until a measured value is assessed as stable is the monitored time interval. The actual duration is mostly longer. 38 ba77077e02 09/2014

39 ORP voltage Freezes the measured value (HOLD function) With the HOLD function, you can freeze the current measured value. The displayed measured value stops changing until you switch the HOLD function off. 1. Freeze the measured value with <HOLD>. The [HOLD] status indicator is displayed. 2. Release the frozen measured value again with <HOLD> or <MODE>. The HOLD function is switched off. The [HOLD] status display disappears Measuring the temperature For reproducible ORP measurements, it is essential to measure the temperature of the test sample. You have the following options to measure the temperature: Automatic measurement of the temperature by the temperature sensor (NTC30 or Pt1000) integrated in electrode. Measurement by an external temperature sensor. Manual determination and input of the temperature. The measuring instrument recognizes whether a suitable sensor is connected and automatically switches on the temperature measurement. The display of the temperature indicates the active temperature measuring mode: Temperature sensor Resolution of the temp. display Temp. measurement yes 0.1 C Automatic with temperature sensor - 1 C Manual If you wish to measure without temperature sensor, proceed as follows: 1. Measure the current temperature of the test sample. 2. Set the temperature value with < >< >. or In the <OK>/U/Man. temperature menu, set the temperature value with < >< >. 7.2 ORP calibration ORP electrodes are not calibrated. You can, however, check ORP electrodes by measuring the ORP of a test solution and comparing the value with the nominal value. ba77077e02 09/

40 Dissolved oxygen 8 Dissolved oxygen 8.1 Measuring Measuring D.O. NOTE When connecting an grounded PC/printer, measurements cannot be performed in grounded media as the values would be incorrect. The USB interface is not galvanically isolated. 1. Connect the D.O. sensor to the meter. The D.O. measuring screen is displayed. 2. If necessary, select the measured parameter with <MODE>. 3. Immerse the D.O. sensor in the test sample. O 2 [OXY 11] 7.9 mg/l 25.1 C :00 USB output 4. If necessary, select the measured parameter with <MODE>. D.O. concentration [mg/l] D.O. saturation [%] D.O. partial pressure [mbar]. Salinity correction When measuring the concentration of solutions with a salt content of more than 1 g/l, a salinity correction is required. For this, you have to measure and input the salinity of the measured medium first. When the salinity correction is switched on, the [SAL] indicator is displayed in the measuring window. You can switch the salinity correction on or off and enter the salinity in the menu for calibration and measurement settings (see section SETTINGS FOR D.O. SENSORS, page 56). Stability control (AutoRead ) The stability control function (AutoRead) continually checks the stability of the measurement signal. The stability has a considerable impact on the reproducibility of measured values (see section AUTOMATIC STABILITY CONTROL, 40 ba77077e02 09/2014

41 Dissolved oxygen Criteria for a stable measured value page 63). The Stability control function checks whether the measured values are stable within the monitored time interval. Measured parameter Time interval Stability in the time interval D.O. concentration 20 seconds Δ : better than 0.05 mg/l D.O. saturation 20 seconds Δ : better than 0.6 % D.O. partial pressure 20 seconds Δ : Better than 1.2 mbar Temperature 15 seconds Δ : better than 0.5 C The minimum duration until a measured value is assessed as stable is the monitored time interval. The actual duration is mostly longer. Freezes the measured value (HOLD function) With the HOLD function, you can freeze the current measured value. The displayed measured value stops changing until you switch the HOLD function off. 1. Freeze the measured value with <HOLD>. The [HOLD] status indicator is displayed. 2. Release the frozen measured value again with <HOLD>. The HOLD function is switched off. The [HOLD] status display disappears Measuring the temperature For reproducible D.O. measurements, it is essential to measure the temperature of the test sample. The temperature is automatically measured by the temperature sensor (NTC30 or Pt1000) integrated in the sensor. The D.O. sensor OXY 11 has an integrated temperature sensor. ba77077e02 09/

42 Dissolved oxygen 8.2 Calibration Why calibrate? D.O. sensors age. This changes the slope of the D.O. sensor. Calibration determines the current slope of the sensor and stores this value in the instrument When to calibrate? After connecting a sensor Routinely within the framework of the company quality assurance When the calibration interval has expired Calibration procedure The provides 2 calibration procedures: Calibration in water vapor-saturated air. Use an OxiCal air calibration vessel for the calibration. Calibration via a comparison measurement (e.g. Winkler titration according to DIN EN or ISO 5813). At the same time, the relative slope is adapted to the comparison measurement by a correction factor. When the correction multiplier is active, the [Factor] indicator appears in the measuring window Calibration in water vapor-saturated air (air calibration vessel) For this calibration procedure, the Comparison meas. setting must be set to Off in the Calibration menu. Proceed as follows to calibrate the instrument: 1. Connect the D.O. sensor to the meter. 2. Put the D.O. sensor into the air calibration vessel. The sponge in the air calibration vessel must be moist (not wet). Leave the sensor in the air calibration vessel for a time long enough to adjust. 3. Start the calibration with <CAL>. The last calibration data (relative slope) is displayed. 42 ba77077e02 09/2014

43 Dissolved oxygen O C OxiCal :00 4. Start the measurement with <OK>. The measured value is checked for stability (stability control). The [AR] status indicator is displayed. A progress bar is displayed and the display of the measured parameter flashes. 5. Wait for the end of the measurement with stability control or accept the calibration value with <OK>. The calibration record is displayed and output to the interface. 6. Using <F1>/[Continue] or <OK>, switch to the measured value display. The meter displays a D.O. saturation of approx % in the air calibration vessel Calibrating with a comparison measurement (OxiComp) For this calibration procedure, the Comparison meas. setting must be set to On in the Calibration menu. Before calibrating via a comparison measurement, the sensor should be calibrated in the air calibration vessel. 1. Connect the D.O. sensor to the meter. 2. Immerse the D.O. sensor in the reference solution. 3. Start the calibration with <CAL>. O mg/l 25.1 C OxiComp :00 ba77077e02 09/

TruLab ph/ise 1320(P)

TruLab ph/ise 1320(P) OPERATIONS MANUAL ba76161e01 08/2015 ph/ise 1320P ph/ise 1320P ph/ise 1320 ph/ise 1320 TruLab ph/ise 1320(P) PH/ISE METER TruLab ph/ise 1320 For the most recent version of the manual, please visit www.ysi.com.

More information

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter Operating manual ph 7310 ph 7310P Printermodul ph 7310P ph 7310 ph meter ba75929e03 12/2011 ph 7310 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited without the

More information

Operating manual. Oxi 3315 O [Sal] mg/l C. Menu. Digital meter for digital IDS dissolved oxygen sensors

Operating manual. Oxi 3315 O [Sal] mg/l C. Menu. Digital meter for digital IDS dissolved oxygen sensors O 2 Operating manual Oxi 3315 [Sal] 7.92 Menu 01.09.2011 25.0 mg/l C 08:37 USB output 3315 Digital meter for digital IDS dissolved oxygen sensors ba75944e01 10/2011 Oxi 3315 Copyright Weilheim 2011, WTW

More information

Cond 7310 Cond 7310P

Cond 7310 Cond 7310P Operating manual Cond 7310 Cond 7310P Printermodul Cond 7310P Cond 7310 Conductivity meter ba75933d02 10/2011 Cond 7310 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited

More information

ph/ion meter IS 2000 L

ph/ion meter IS 2000 L ph/ion meter IS 2000 L INSTRUCTION MANUAL mg/l ECN: 665-0190 Version: 5 Issued: 14, 3, 2011 ba75856e05 03/2011 IS 2000 L VWR International bvba Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven

More information

Operating manual. Multi 350i CAL STO ESC. ph / ISE / DO / conductivity measuring instrument. ba75420e04 03/2005

Operating manual. Multi 350i CAL STO ESC. ph / ISE / DO / conductivity measuring instrument. ba75420e04 03/2005 Operating manual Multi 350i M PRT CAL STO O ESC ph / ISE / DO / conductivity measuring instrument ba75420e04 03/2005 Accuracy when going to press Currentness of firmware The use of advanced technology

More information

OPERATING MANUAL. ba75863e19 04/2015. Multi 3410 DIGITAL METER FOR DIGITAL IDS SENSORS

OPERATING MANUAL. ba75863e19 04/2015. Multi 3410 DIGITAL METER FOR DIGITAL IDS SENSORS OPERATING MANUAL ba75863e19 04/2015 Multi 3410 DIGITAL METER FOR DIGITAL IDS SENSORS Multi 3410 The latest version of the present operating manual is available on the Internet under www.wtw.com. Copyright

More information

Operating manual. Multi Digital ph / D.O. / conductivity meter for 2 digital IDS sensors

Operating manual. Multi Digital ph / D.O. / conductivity meter for 2 digital IDS sensors Operating manual Multi 3420 Digital ph / D.O. / conductivity meter for 2 digital IDS sensors ba75864e09 07/2010 Multi 3420 Accuracy when going to press The use of advanced technology and the high quality

More information

OPERATING MANUAL. ba75803e06 06/2013. [Tr25][nLF][ /cm] μs/cm. Menu. Cond 3310 CONDUCTIVITY METER

OPERATING MANUAL. ba75803e06 06/2013. [Tr25][nLF][ /cm] μs/cm. Menu. Cond 3310 CONDUCTIVITY METER ӕ [Tr25][nLF][ 0.835 1/cm] 1417 C OPERATING MANUAL ba75803e06 06/2013 Menu 25.0 μs/cm 15.11.2008 08:37 USB output Cond 3310 CONDUCTIVITY METER Cond 3310 For the most recent version of the manual, please

More information

OPERATING MANUAL. ba77041e02 11/2015. HandyLab 680. HandyLab 680 DIGITAL METER FOR DIGITAL IDS SENSORS

OPERATING MANUAL. ba77041e02 11/2015. HandyLab 680. HandyLab 680 DIGITAL METER FOR DIGITAL IDS SENSORS OPERATING MANUAL ba77041e02 11/2015 HandyLab 680 HandyLab 680 DIGITAL METER FOR DIGITAL IDS SENSORS HandyLab 680 For the most recent version of the manual, please visit www.si-analytics.com. Copyright

More information

1000 L INSTRUCTION MANUAL

1000 L INSTRUCTION MANUAL ph meter ph 1000 L INSTRUCTION MANUAL ph 6 9 9 2 2 4 8 Auto C TP ECN: 662-1422 Version: 7 Issued: 23, 10, 2012 ba75836e07 10/2012 ph 1000 L VWR International bvba Researchpark Haasrode 2020 Geldenaaksebaan

More information

Handheld meter ph 330i/340i

Handheld meter ph 330i/340i Operating manual Handheld meter PH M 6 9 9 2 2 4 6 C TP CAL RCL STO O AR ph measuring instrument ba52310e03 03/2004 Accuracy when going to press The use of advanced technology and the high quality standard

More information

Operating manual M545P M 545P. Pinnacle series. Laboratory ph meter. ba75564e03 02/2007

Operating manual M545P M 545P. Pinnacle series. Laboratory ph meter. ba75564e03 02/2007 Operating manual M545P ph 6 9 9 2 2 4 8 M 545P Pinnacle series C TP Laboratory ph meter M 545P Accuracy when going to press The use of advanced technology and the high quality standard of our meters are

More information

ProLab 4000 ph/ise/conductivity

ProLab 4000 ph/ise/conductivity OPERATING MANUAL ba75646e04 04/2013 ProLab 4000 ph/ise/conductivity MEASURING INSTRUMENT WITH AUTOMATIC SENSOR RECOGNITION AND ELECTRONIC ACCESS CONTROL ProLab 4000 Copyright 2009, SI Analytics GmbH Reprinting

More information

Operating manual M530P M 530P. Pinnacle series. Laboratory ph meter. ba75562e02 12/2005

Operating manual M530P M 530P. Pinnacle series. Laboratory ph meter. ba75562e02 12/2005 Operating manual M530P ph 6 9 9 2 4 8 M 530P Pinnacle series C TP Laboratory ph meter M 530P Accuracy when going to press The use of advanced technology and the high quality standard of our meters are

More information

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet English ph / ISE / COND / RDO / DO Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the

More information

Operating manual. ph/ion/cond 750. Multiparameter laboratory meter for ph, ion concentration and conductivity

Operating manual. ph/ion/cond 750. Multiparameter laboratory meter for ph, ion concentration and conductivity Operating manual inolab ph/ion/cond 750 ph/ion/cond 750 Multiparameter laboratory meter for ph, ion concentration and conductivity Accuracy when going to press The use of advanced technology and the high

More information

Operating manual. VARIO ph. Hand-held ph meter

Operating manual. VARIO ph. Hand-held ph meter Operating manual VARIO ph Hand-held ph meter ba75373e04 07/2006 VARIO ph Accuracy when going to press The use of advanced technology and the high quality standard of our instruments are the result of continuous

More information

for measuring ph values and redox potential, conductivity and dissolved oxygen Content

for measuring ph values and redox potential, conductivity and dissolved oxygen Content for measuring ph values and redox potential, conductivity and dissolved oxygen Content Portable ph meters with GLP functions handylab ph 11 and handylab ph 12 Page 32 Technical data handylab LF 11, handylab

More information

ProLab Operating manual. ph / ISE / conductivity / D.O. meter with automatic sensor recognition and electronic access control

ProLab Operating manual. ph / ISE / conductivity / D.O. meter with automatic sensor recognition and electronic access control Operating manual ProLab 2000 OK MENU ph / ISE / conductivity / D.O. meter with automatic sensor recognition and electronic access control ba75577e03 11/2009 DRAFT November 25, 2009 2:33 pm Accuracy when

More information

ProLab Operating manual. ph / ISE meter with automatic sensor recognition and electronic access control. DRAFT January 18, :18 pm

ProLab Operating manual. ph / ISE meter with automatic sensor recognition and electronic access control. DRAFT January 18, :18 pm Operating manual ProLab 1000 OK MENU ph / ISE meter with automatic sensor recognition and electronic access control ba75576e04 01/2011 DRAFT January 18, 2011 3:18 pm Accuracy when going to press The use

More information

Operating Manual. inolab ph Level 2. Laboratory ph meter with integrated printer. ba12219e04 10/

Operating Manual. inolab ph Level 2. Laboratory ph meter with integrated printer. ba12219e04 10/ Operating Manual inolab ph Level 2 Laboratory ph meter with integrated printer ba12219e04 10/2002 73 Accuracy when going to press The use of advanced technology and the high quality standard of our instruments

More information

Accuracy when going to press

Accuracy when going to press Accuracy when going to press The use of advanced technology and the high quality standard of our instruments are the result of continuous development. This may result in differences between this operating

More information

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet English ph / RDO / DO Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug

More information

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet English ph / COND Thermo Scientific Orion Star A325 Portable ph/conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug

More information

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Handhelds For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Single Parameter Instruments Data-logging Ground Water Wastewater Surface waters Quality Fishfarming 3110 Series and 3205 :

More information

photoflex STD Handheld colorimeter

photoflex STD Handheld colorimeter OPERATIONS MANUAL ba76122e01 02/2013 STD photoflex STD Handheld colorimeter photoflex STD For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725 Brannum Lane Yellow

More information

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements ProLab 1000: ph for the professional ProLab 1000: Superior technique in a classy metal body Precise measurements With a measuring range of -2.000 up to +20.000 ph and an accuracy of 0.003 ph the ProLab

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

inolab 740 with terminal 740

inolab 740 with terminal 740 RUN ENTER AR inolab Operating manual with terminal 740 Cond 730 measuring system with active multifunction boxes and 740 terminal ba75446e04 06/2007 Accuracy when going to press The use of advanced technology

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet English ph / ISE Thermo Scientific Orion Star A324 Portable ph/ise Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket plug plate.

More information

inolab 7000 Series Accurate. Compliant. Sensitive. The inolab family: Advanced measuring technology offers new functions including automatic AutoRead

inolab 7000 Series Accurate. Compliant. Sensitive. The inolab family: Advanced measuring technology offers new functions including automatic AutoRead inolab 7000 Series MEASUREMENT OF ph, ISE, CONDUCTIVITY AND DISSOLVED OXYGEN ACCURATE, COMPLIANT AND SENSITIVE inolab 7000 Series Accurate. Compliant. Sensitive. The inolab family: Advanced measuring technology

More information

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet English ph / ISE Thermo Scientific Orion Star A214 Benchtop ph/ise Meter Instruction Sheet Preparation Power Source 1. Power adapter (included with meter) a. Select the appropriate wall socket plug plate.

More information

ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements Communic

ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements Communic ProfiLine Handhelds For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements

More information

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Sartorius Electrochemistry: ph Conductivity DO Meters Quality and Convenience Sartorius approach is to offer a complete range of

More information

Handheld Water Quality Meters 100 Series

Handheld Water Quality Meters 100 Series ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere

More information

User Manual. Thermo Scientific Orion Star A320 Series

User Manual. Thermo Scientific Orion Star A320 Series User Manual Thermo Scientific Orion Star A320 Series Electrochemistry Portable Meters 68X000443 Revision A June 2015 Important Note Please read this user guide thoroughly before using your meter. Any use

More information

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter English Cond Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket

More information

Portable Conductivity Meter M1410. User Manual 1.002

Portable Conductivity Meter M1410. User Manual 1.002 Portable Conductivity Meter M1410 User Manual 1.002 General information This manual describes the operation of the Portable Conductivity Meter M1410. Please read this entire manual before operating this

More information

Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter. Instruction Sheet

Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter. Instruction Sheet English RDO / DO Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket

More information

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Quality Electrochemical Analysis Professional Meters Basic Meters Sensors Sartorius Electrochemistry: ph Conductivity DO Meters Quality and Convenience Sartorius approach is to offer a complete range of

More information

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures Multiparameter Waterproof Meters Multiparameter measurement in compact, IP67 rated waterproof enclosures HI98194 Features HI98194 Multiparameter Waterproof Meter ph, ORP, EC, TDS, Resistivity, Salinity,

More information

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A Series Benchtop multi-parameter water quality meter LMPWM-A series is comes with different measurement modes for quality and testing of water on different parameters. It measures ph, Conductivity,

More information

Hanna Instruments HI9819X Multiparameter series

Hanna Instruments HI9819X Multiparameter series Hanna Instruments HI9819X series www.hannainst.com HI98194 Waterproof Meter ph / mv, ORP, EC, TDS, Resistivity, Salinity, Seawater σ, Dissolved Oxygen, Atmospheric Pressure and Waterproof IP67 rated waterproof,

More information

Benchtop and portable meters

Benchtop and portable meters Descriptions Benchtop and portable meters Content IDS Intelligent digital sensors IDS goes wireless Benchtop meters inolab Multi IDS digital Portable meters MultiLine IDS digital Benchtop meters inolab

More information

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual Colorado Series CR-10 Portable ph / mv / Temperature Meter Operation Manual 2 Contents Page General Introduction and Initial Inspection.............................. 4 Safety Infomation..................................................

More information

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus INSTRUCTION MANUAL Portable ph and ph/ise Meters Models 210Aplus 230Aplus 250Aplus 290Aplus Table Of Contents Chapter I Introduction................................1 Chapter II General Information.........................3

More information

and Multiparameter Meters

and Multiparameter Meters and Multiparameter Meters 54650-23 ph Menu Options Table 1 How to Change ph Menu Options Setup Setup 1 Time Setup 2 Date Setup 3 Year Setup 4 Temperature Units Setup 5 Display Lock Setup 6 Measurement

More information

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters Electrochemistry Meters Series SD (IP 67 waterproof) 82 The new AQUALYTIC SD series comprises a range of compact, easy-to-use, hand-held instruments for the accurate measurement of ph, ORP, Con, TDS or

More information

Portavo 904 X Multi. Multiparameter Ex

Portavo 904 X Multi. Multiparameter Ex Multiparameter Ex Portavo 904 X Multi The world's only portable device for liquid analysis with ATEX approval for measurements up to zone 0/1. Ideal for applications in the process industry. For the first

More information

ProLab Operating manual. ph/ise meter with automatic sensor recognition and electronic access control. DRAFT January 28, :34 pm

ProLab Operating manual. ph/ise meter with automatic sensor recognition and electronic access control. DRAFT January 28, :34 pm Operating manual ProLab 3000 ph/ise meter with automatic sensor recognition and electronic access control ba75645e02 01/2010 DRAFT January 28, 2010 2:34 pm Accuracy when going to press The use of advanced

More information

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures Multiparameter Waterproof Meters Multiparameter measurement in compact, IP67 rated waterproof enclosures HI98195 Features HI98195 Multiparameter Waterproof Meter ph, ORP, EC, TDS, Resistivity, Salinity,

More information

Agilent 3200M Multi-Parameter Analyzer

Agilent 3200M Multi-Parameter Analyzer Agilent 3200M Multi-Parameter Analyzer User Guide Agilent Technologies Notices Agilent Technologies (Shanghai) Co., Ltd. 2012 No part of this manual may be reproduced in any form or by any means (including

More information

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Dissolved Oxygen Meter Kit DOK. Instruction Manual Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:

More information

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad

Research Grade Meters. ph, ISE, EC and DO. Laboratory bench meters with a color, graphic display and capacitive touch keypad Research Grade Meters ph, ISE, EC and DO Laboratory bench meters with a color, graphic display and capacitive touch keypad HI5000 Series Research Grade Meters Overview HI5000 Series Research Grade Meters

More information

ProLab Operating manual. ph/ise/conductivity measuring instrument with automatic sensor recognition and electronic access control

ProLab Operating manual. ph/ise/conductivity measuring instrument with automatic sensor recognition and electronic access control Operating manual ph/ise/conductivity measuring instrument with automatic sensor recognition and electronic access control ba75646e03 12/2012 DRAFT December 10, 2012 1:25 pm Accuracy when going to press

More information

MultiLine IDS Portable Meters. PORTABLE MULTIPARAMETER MEASUREMENT OF ph, DISSOLVED OXYGEN, CONDUCTIVITY AND TURBIDITY

MultiLine IDS Portable Meters. PORTABLE MULTIPARAMETER MEASUREMENT OF ph, DISSOLVED OXYGEN, CONDUCTIVITY AND TURBIDITY MultiLine IDS Portable Meters PORTABLE MULTIPARAMETER MEASUREMENT OF ph, DISSOLVED OXYGEN, CONDUCTIVITY AND TURBIDITY Advantages by IDS Intelligent, digital Sensors measure and combine measurement results

More information

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at User Manual ExStik EC500 ph/conductivity / TDS / Salinity / Temperature Meter EC500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the

More information

Integrated Instruction Manual WP 600 Series Meters

Integrated Instruction Manual WP 600 Series Meters Integrated Instruction Manual WP 600 Series Meters ph 600/ 610/ 620, COND 600/610, DO 600, PC 650, PD 650, CD 650, PCD 650 68X415307 Rev. 1 Oct 07 Part of Thermo Fisher Scientific Technology Made Easy...

More information

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting

More information

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM English Operating manual Multiparameter portable instrument HD98569 Companies / Brands of GHM www.deltaohm.com Keep for future reference. TABLE OF CONTENTS Introduction... 6 Display Description... 7 Keyboard

More information

SensoDirect ph200 ph-/redox-/temperature Meter Operating instructions

SensoDirect ph200 ph-/redox-/temperature Meter Operating instructions SensoDirect ph200 ph-/redox-/temperature Meter Operating instructions mv Rel mv ph % C C MEAS HOLD F ATC OK CAL Meas Cal Hold Rcl Store On Off Menu GB Declaration of CE-Conformity The manufacturer: Tintometer

More information

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 TI01198C/07/EN/02.15 71288268 Products Solutions Services Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 Portable multiparameter device for Memosens ph, conductivity and oxygen

More information

portable waterproof multiparameter meter

portable waterproof multiparameter meter water resistant battery powered interchangeable electrode DIN connection replaceable electrode portable waterproof multiparameter meter Professional testing and analysis out in the field is supported by

More information

ph/orp Meter SD Card real-time Datalogger

ph/orp Meter SD Card real-time Datalogger User's Guide ph/orp Meter SD Card real-time Datalogger Model SDL100 Introduction Congratulations on your purchase of the Extech SDL100 ph/orp Meter, an SD Logger Series meter. This meter displays and stores

More information

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations Digital electrodes edge performs measurements through its unique

More information

Instruction Manual HI Multiparameter Meter with GPS

Instruction Manual HI Multiparameter Meter with GPS Instruction Manual HI 9828 Multiparameter Meter with GPS w w w. h a n n a i n s t. c o m 1 Dear Customer, Thank you for choosing a HANNA instruments product. Please read this instruction manual carefully

More information

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:

More information

Handheld Water Quality Meters 100 Series

Handheld Water Quality Meters 100 Series ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere

More information

Logger WQL-Cond PC program WQL-Log

Logger WQL-Cond PC program WQL-Log Operating manual Logger PC program WQL-Log Logger for conductivity measurement and PC program to display and evaluate the data from the logger ba75822e03 02/2012 DRAFT: Friday, 17. February 2012 WQL-Log

More information

WK7200. Water Quality Test Kit USER S MANUAL

WK7200. Water Quality Test Kit USER S MANUAL WK7200 USER S MANUAL Water Quality Test Kit INTRODUCTION: Thank you for selecting model WK7200 microprocessor-based waterproof Water Quality Test Kit. It is used to measure a wide range of ph, ORP, Conductivity,

More information

HI 3220 HI 3221 HI 3222

HI 3220 HI 3221 HI 3222 Instruction Manual HI 3220 HI 3221 HI 3222 Calibration Check ph/mv/ise/temperature Bench Meters WARRANTY The HI 322x series are guaranteed for two years against defects in workmanship and materials when

More information

Instruction Manual HI Multiparameter

Instruction Manual HI Multiparameter Instruction Manual HI 9828 Multiparameter w w w. h a n n a i n s t. c o m 1 2 Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.

More information

Handheld Water Quality Meters 100 Series

Handheld Water Quality Meters 100 Series ph ORP Ion Conductivity Resistivity TDS DO Salinity Handheld Water Quality Meters 100 Series METERS 2 YEAR W A R R A N T Y M A D E I N J A P A N www.horiba-laqua.com In the lab, in the field or anywhere

More information

703 Laboratory Conductivity Meter

703 Laboratory Conductivity Meter 703 Laboratory Conductivity Meter Sensoface Sensoface monitors the sensor and measuring equipment and provides information on sensor selection and handling. It reports clock memory loss and requests regular

More information

User Manual. Portamess 913 Cond and Portamess 913 X Cond

User Manual. Portamess 913 Cond and Portamess 913 X Cond User Manual Portamess 913 Cond and Portamess 913 X Cond Warranty Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender).

More information

DO Meter Kit. Instruction Manual

DO Meter Kit. Instruction Manual DO Meter Kit 850048 Instruction Manual DO Meter Kit 850048 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any

More information

Operating the meter 13. j h g. 4.1 Backside layout Pin assignments RS232 connection

Operating the meter 13. j h g. 4.1 Backside layout Pin assignments RS232 connection 4 Operating the meter 4.1 Backside layout c d e f a b j h g a b c d e f g h i BNC socket for mv/ph signal input RCA (Cinch) socket for temperature signal input Reference socket for reference electrodes

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual. 99 Washington Street Melrose, MA 0276 Fax 78-665-0780 TestEquipmentDepot.com DPI 820 Dual Input Thermometer User manual A B 0 0 0a 9a A 2 9 8 2 3 7 6 4 5 B 2 A2 6 5 4 3 22 7 8 2 9 20 Test Equipment Depot

More information

ph 300 ph 301 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ C Meters Instruction Manual

ph 300 ph 301 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ C Meters Instruction Manual Instruction Manual ph 300 ph 30 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ Meters Rel mv ppm ph DATE TIME MEM mv ppm ph INTV WRONG m BUF 2 s LOG 3 ON OFF PAPER PRINT ph302 ph METER RANGE / TIME PGM

More information

ph and Electrochemistry

ph and Electrochemistry Portable Meters Portable Meters At-a-Glance Selection Guide Take your measurements into the great outdoors. Our Orion Star A series portable meters are built rugged and waterproof for dependable performance.

More information

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or F) Automatic

More information

Instruction Manual HI Multiparameter Meter with GPS

Instruction Manual HI Multiparameter Meter with GPS Instruction Manual HI 9828 Multiparameter Meter with GPS w w w. h a n n a i n s t. c o m 1 2 Dear Customer, Thank you for choosing a HANNA instruments product. Please read this instruction manual carefully

More information

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no PV Remote Unit A 1378 Instruction manual Version 2.1, Code no. 20 752 010 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: metrel@metrel.si

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

Introduction: Features:

Introduction: Features: Index Features:... 3 Specifications:... 4 Accessories:... 5 Functions of Keyboard:... 7 Preparation:... 8 ... 8 ... 8 Calibration:... 8 ... 8 ... 9 ...

More information

Submersion/Insertion ph/orp Sensors

Submersion/Insertion ph/orp Sensors Instruction Sheet PN 51A-396VP/rev.G January 2011 Models 396VP and 398VP Submersion/Insertion ph/orp Sensors For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/.

More information

Portavo 921 S. Portavo S. The Basic Unit

Portavo 921 S. Portavo S. The Basic Unit Portavo S Portavo 921 S The Basic Unit For mobile measurement of ph, digital-ph and ORP. The sensors are connected via tightly screwed-in measuring modules, which include matching circuitry for the respective

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual C100 Handheld Cond./TDS/Sal. Meter Instruction Manual Table of Contents 1. Introduction ---------------------------------------------------------------------------------------------------------------------------

More information

WTW Multi 340i/3400i Portable Meters

WTW Multi 340i/3400i Portable Meters WTW Multi 340i/3400i Portable Meters The rugged, versatile Multimeter This waterproof (IP 66) instrument with battery or optional line adaptor also meets the requirements of IP 67 and is optimally suited

More information

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines Operating manual Conductivity measuring cell to be installed in pipelines ba55321de02 10/2010 Copyright Weilheim 2010, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written

More information

Portable ph/orp/conductivity Meter D-74 Instruction Manual CODE:GZ

Portable ph/orp/conductivity Meter D-74 Instruction Manual CODE:GZ Portable ph/orp/conductivity Meter D-74 Instruction Manual CODE:GZ0000333608 Preface This manual describes the operation of the Portable ph/orp/conductivity Meter D-74. Be sure to read this manual before

More information

Instruction Manual HI 2550 Multiparameter ph/orp/ C EC/TDS/NaCl Bench Meter

Instruction Manual HI 2550 Multiparameter ph/orp/ C EC/TDS/NaCl Bench Meter Instruction Manual HI 2550 Multiparameter ph/orp/ C EC/TDS/NaCl Bench Meter www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully

More information

Field-Lab Analysers for ph, mv, Conductivity, TDS, Salinity, Dissolved Oxygen, Turbidity & Temperature

Field-Lab Analysers for ph, mv, Conductivity, TDS, Salinity, Dissolved Oxygen, Turbidity & Temperature [Add this page to the Navigation view to display hyperlinks here] [Add this page to the navigation structure to display a page banner here] TPS Australia - Quality instruments since 1968. Field-Lab Analysers

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

Research Grade Meters

Research Grade Meters HI5521 HI5522 Research Grade Meters ph/orp/ise and EC/TDS/Resistivity/Salinity and Temperature bench Conductivity/TDS Measure up to Eight Parameters HI5521 and HI5522 are research grade benchtop instruments

More information

Electrodes ph EC DO /14 dge 2 P/L e

Electrodes ph EC DO /14 dge 2 P/L e ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand Manual log on stability Interval logging Temperature readout ( C or

More information