Merging unit ENMU. Manual
|
|
- Bruce Doyle
- 5 years ago
- Views:
Transcription
1 Merging unit ENMU Manual ENMU manual. Rev
2 Table of content Table of content Introduction... 3 Glossary General information Features Specification Measurement inputs Operating condition Digital interfaces Power supply Dimension Operation Package content Before performing installation Mounting Terminal connections Configuring Maintenance Transport, packing and storage Warranty information ENMU manual. Rev
3 Introduction Introduction The Manual describes information about functions, recommendations for use, technical support, maintenance, packing, transportation, storage, as well as connection diagrams to electrical grid and digital interfaces. Read this manual carefully before using the device. Typical users Engineers, personnel who refers with setting, operations and maintenance. Validity range This manual applies to all ENMU modification. Support For questions about devices, please contact with technical support «Engineering center «Energoservice»: Website: Phone: +7 (8182) ATTENTION: Use ENMU only according to this manual; ENMU should be installed, operated and maintained only by qualified personnel; Do not use any cleanser except recommended by manufacturer; Save ENMU from impact; Before connecting ENMU, you must ensure that the local power supply conditions agree with the specifications on the label on the ENMU. NOTICE: - The information contained in this document is subject to change without notice; - New features may be added to devices without notice. ENMU manual. Rev
4 Glossary Glossary CT current transformer; PPS pulse per seconds; Process Bus process bus according to IEC ; PRP - Parallel Redundancy Protocol (IEC Clause 4); PT potential transformer. SV Sampled Values (IEC ); ENMU manual. Rev
5 General information 1 General information Figure 1.1. ENMU front and side panels. According to IEC ENMU belongs to SAMU (Stand-Alone Merging Unit) class. ENMU provides Sampled Values (SV) data transmission according to Implementation Guidelines for Digital Interface to Instrument Transformers using IEC LE. ENMU has three optical fiber Fast Ethernet 100Base-FX interfaces. «Lan A» and «Lan B» and can be configured to operate as a PRP node to provide seamless failover. ENMU digitizes the analog input signals and transmits synchronized SV data to Process Bus via optical interfaces (max. 4 streams). SV stream is used as an input signal for protection devices, power meters, PMU etc. In addition, ENMU supports data transmit via IEC and IEEE C ENMU manual. Rev
6 Features 2 Features ENMU transmits synchronized SV data according to IEC LE SV80 (sampling rate 4000 Hz (50 Hz) or 4800 Hz (60 Hz) 80 samples per cycle), and SV256 (sampling rate Hz (50 Hz) or (60 Hz) 256 samples per cycle). ENMU supports up to 4 SV streams (2 SV80, 2 SV256) with configurable data (PT voltage, measuring CT current, protective CT current). ENMU is connected to Process Bus via fiber optic Ethernet 100Base-FX «Lan А» and «Lan B» interfaces. IEC and IEEE C data transmission available via «Lan А», «Lan B» and «Lan 1». ENMU supports redundancy technology PRP according to IEC for SV streams. IED IED IED IED Switch LAN A Switch LAN B SV SV SV SV SV SV SV SV ENMU ENMU ENMU ENMU CT PT CT PT CT PT CT PT GPS sync sync sync sync ENCS-2 RS-485 PPS/IRIG-A/B ESMC-1 ENMU is synchronized by external signals PPS, IRIG-A or IRIG-B, connected via fiber optic interface Sync. ENMU has SD card for saving oscillograms. It can be triggered by activate threshold. Values Ia, Ib, Ic, Ua, Ub, Uc are recorded with frequency 32/64/128/256 samples per cycles. ENMU has two independent power supplies for connection to independent power sources. ENMU manual. Rev
7 Specification 3 Specification 3.1 Measurement inputs PT output connected to terminals U a, U b, U c, 3U 0. Table 3.1 Voltage input parameters Meaning Nominal phase voltage, V 57.7 Input channels U a, U b, U c, 3U 0 Voltage measurement range, % from nominal voltage Voltage accuracy, % 0.2 Sampling rate 4000/12800 Hz or 4800/15360 Hz Delay before transmit Up to 100 µs Measuring CT output connected to terminals I a, I b, I c, I 0. Protective CT output connected to terminals I a, I b, I c. Table 3.2 Current input parameters Measuring input Protective input Nominal current, A 1 or 5 Input channels I a, I b, I c, I 0 I a, I b, I c Measurement range, % from nominal current Accuracy, % TVE, % - <1 Sampling rate 4000/12800 Hz or 4800/15360 Hz Delay before transmit Up to 100 µs If conditions not match specified in Table 3.5, ENMU has additional measurement error according to following table. Table 3.3 Condition value Temperature, С Current, voltage Strength of the magnetic field, mt 0.5 Current, voltage Input freqency 50 5 Hz Current, voltage Added error X 1, % 0.1/10 С 0.1% 0.8% Current input burden is up to 0.1 VA. Voltage input burden is up to 0.1 VA. Below is an example of an actual error of forming the stream of Sample Values correlated with the boundaries of the permissible measurement errors for classes 0.2S, 0.1. ENMU manual. Rev
8 Specification Figure 3.1. Current accuracy. Figure 3.2. Voltage accuracy. ENMU manual. Rev
9 Specification 3.2 Operating condition Table 3.4 Condition Value 1 Temperature, С Relativity humanity,% 5-95 non-condensing 3 Operation mode continuous 4 Turn-on time <30 sec 5 MTBF h 6 Device life 15 year 7 Seismic sustainability Up to 6 degree MSK-64 8 Input frequency, Hz 50±5 or 60±5 9 Input measuring current load, % of nominal Input protective current load, % of nominal Input voltage load, % of nominal Normal condition see in table 4.4. Table 3.5 Condition Normal value (or normal range) Temperature, С Relativity humanity,% Atmospheric pressure, kpa (mmhg) ( ) Strength of the magnetic field Position Magnitude of Earth's magnetic field any Supply frequency, Hz Variation 0.5 mt at (50/60 1) Hz Supply voltage AC sinusoidal Voltage distortion up to 5 % 3.3 Digital interfaces Figure 3.3. Digital interfaces. Digital interfaces description in following table: Table 3.6 Interface Meaning Standard Type SV stream output; configuring; data Ethernet 100Base-FX, «LAN A», transmit over IEC , PRP according to IEC «LAN B» IEEE C , FTP «LAN 1» Configuring; data transmit over IEC , IEEE C , FTP Ethernet 100Base-FX Duplex LC, 100 Mb/s, multimode 50/125 µm, 1300 nm SYNC Time sync from PPS 1 Hz, IRIG-A(B) According to IEC ST, multimode {ed1.0} 50/125 µm, 820 nm USB Service port for firmware update. USB type B ENMU manual. Rev
10 Specification PPS parameters: Trigger level 50 % from max bright PPS impulse duration More then 10 µs PPS step More then 500 µs PPS signal source ENCS ESMC or other 3.4 Power supply ENMU has two independent power supplies. Table 3.7 Parameter AC voltage DC voltage Power supply consumption Value V, Hz V 15 VA 3.5 Dimension ENMU dimension in mm see in Fig. 3.4 Figure 3.4. Dimensions (in mm). ENMU manual. Rev
11 Operation 4 Operation 4.1 Package content Table 4.1 Merging unit Mounting brackets CD with software («ES Configurator», «BootLoader», «ES Find IP») and ENMU Manual ENMU x2 ENMU Before performing installation After receiving ENMU from manufacturer, make sure that packing has no defects. Unpacking ENMU, check the package contents. Compare characteristics in passport with label on front side of device. ENMU operation should be as manual only. Before connect/disconnect ENMU to digital interface or measuring inputs, make sure that all sources of power supply are disconnected. ENMU connects only to current and potential transformers with suitable characteristics. Connection to IEC LE Bus carried out in accordance with the operational documentation. Do not use ENMU in explosive or corrosive environment. Save ENMU from heating above 70 С, large temperature variations and strong electro-magnetic fields. 4.3 Mounting For safety, you must read the instructions in this manual before performing mounting and operation. Only qualified personnel should be allowed for installation. ENMU has 2 bracket for cabinet surface mounting. Allowed mounting ENMU device at any angle to the horizontal. Dimension see in Fig ENMU manual. Rev
12 Operation 4.4 Terminal connections ENMU Measuring CT «PWR-1» I A I A I B PE N / - L / I B I C I C I 0 I 0 «PWR-2» PE N / - L / «APS» Protective CT I A I A I B I B I C I C «LAN 1» Ethernet 100Base-FX (multimode) Tx Rx LC 15 PT U A «LAN A» Ethernet 100Base-FX (multimode) Tx Rx LC U A U B U B U C U C «LAN B» Ethernet 100Base-FX (multimode) Tx Rx LC U 0 3U 0 «SYNC» Ethernet 100Base-FX (multimode) Rx ST USB Type B Figure 4.1 Tightening torque is 0.5 to 0.6 N m ENMU manual. Rev
13 Operation Terminals Recommended wire size Power supply 2.5 mm 2 wires (AWG 14) Voltage input 4 mm 2 wires (AWG 12) Measuring current input 6 mm 2 wires (AWG 10) Protective current input 16 mm 2 wires (AWG 5) ENMU must be connected to Process Bus using optical fiber cable. Optical interfaces LAN A, «LAN B», «LAN 1» Sync Parameters LC socket, multimode 50/125 µm, 1300 nm ST socket, multimode 50/125 µm, 1300 nm 4.5 Configuring Software «ES Configurator» Software «ES Configurator» are used for configuring ENMU. The last version of configuration software you can download here: You need PC with Windows XP or newer and.net Framework 4. Download.NET Framework 4 distributive from the official site here: To install the program, just copy and unzip downloaded archive file in some folder on your PC. For launch the program, just run the executable file ESConfigurator.exe. After launch, you will see the program main form (see Figure 4.2). ENMU manual. Rev
14 Operation Figure 4.2 Full description of software see in «ES Configurator manual» Default SV settings Parameter SV80-1 SV80-2 Analog Voltage, Measuring Current Voltage, Protective Current SV ID ENS80pointMU01 ENS80pointMU01 Interface LAN A LAN B VLAN disable disable MAC-address 01-0C-CD FF 01-0C-CD FF Parameter SV256-1 SV256-2 Analog Voltage, Measuring Current Voltage, Protective Current SV ID ENS256MUnn01 ENS256MUnn02 Interface LAN B LAN B VLAN disable disable MAC-address 01-0C-CD FF 01-0C-CD FF ENMU manual. Rev
15 Maintenance 5 Maintenance Maintenance should be according to this manual. Only qualified personnel should perform it. Repair of defective device produced by manufacturer. Do not open the housing during operation. Opening the ENMU voids the warranty. For preventive maintenance, follow instruction bellow: Disconnect power supply, digital interface, measuring inputs; Remove dust; Check device for defects; Check mount; Connect power supply, digital interface, measuring inputs. For cleaning use nonabrasive detergent or 70% ethanol-water solution. ENMU manual. Rev
16 Transport, packing and storage 6 Transport, packing and storage ENMU is transported in any covered transport (railway, car, aviation). Transports conditions temperature is ⁰С, relative humidity is 95 % at 30⁰С. Save ENMU from impact during the transport. ENMU is delivered in packaging case. Package has content according to page 11. Net weight up to 3 kg. Gross weight up to 4 kg. Store the device in dry and clean location. Storage condition in follow table: Condition Device in manufacturer packing Device without manufacturer packing Temperature C C Relative humidity 80% (at +25 C) 80% (at 25 C) ENMU manual. Rev
17 Warranty information 7 Warranty information The manufacturer offers the customer a 36-month functional warranty on the instrument for faulty workmanship or parts from date of dispatch from the distributor. In all cases, this warranty is valid for 48 months from the date of production. This warranty is on a return to factory basis. The manufacturer does not accept liability for any damage caused by instrument malfunction. The manufacturer accepts no responsibility for the suitability of the instrument to the application for which it was purchased. Failure to install, set up or operate the instrument according to the instructions herein will void the warranty. Only a duly authorized representative of the manufacturer may open your instrument. The unit should only be opened in a fully anti-static environment. Failure to do so may damage the electronic components and will void the warranty. ENMU manual. Rev
FL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationDRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.
The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationDRTS 33. The new generation of advanced three phase relay test set
The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationPHOENIX CONTACT - 10/2009
Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used
More informationTHE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.
D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,
More informationOPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM
OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...
More informationDRTS 66 can test all the following relays
Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs
More informationISF3018D Series Ring Network Industrial Ethernet Switch
ISF3018D Series Ring Network Industrial Ethernet Switch Key Features: iring for network redundancy. Support VLAN configuration IP40 protection class, fully enclosed metal cabinet Exceeds Industrial class
More informationOPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM
OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF
More informationModel P4017 Single Channel USB Oscilloscope. Quick Start Guide
Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase
More informationRGM180 Display Series
Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or
More informationMF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide
1 INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER Installation Guide October 2008 VERSITRON, Inc. 83C Albe Drive Newark, DE 19702 800-537-2296 2 PROPRIETARY DATA All data in this manual is proprietary
More informationOPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER
/ OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationOPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE
OPERATOR MANUAL OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER WITH PoE SOURCE INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4
More informationDRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System
Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)
More informationFL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C
16-Port Standard Function Ethernet Switches for Normal and Extreme Environments AUTOMATION Data Sheet 2806_en_C 1 Description PHOENIX CONTACT 2011-06-28 2 Features and Benefits The FL SWITCH SFN(T) 16(15)(14)TX
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationTable of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A
Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication
More information10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide
10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001 Installation Guide DOC.050523-EM400X -1- The information contained in this document is subject to change without prior notice. Copyright (C) All
More informationModemUSB/E12 User Manual v0.1
User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS...2 1. ATTENTION...3 2. FOR YOUR SAFETY...3 3. USER S SERVICE...5 4. BASIC INFORMATION...6 4.1 Introduction...6 4.2 Legal Notice...6 4.3 Contacts...6
More informationOPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM
OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...
More informationOPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER
OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER INDEX 1 1 TECHNICAL SUMMARY... 5 1.1 BRIEF DESCRIPTION... 5 1.1.1 OVERVIEW... 5 1.1.2 APPLICATIONS... 5 1.1.3 FEATURES AND BENEFITS... 5
More informationIndustrial 3-Port Fast Ethernet Media Converter Switches
Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation
More informationUser Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor
User Manual Rack Mount Display Monitor - 4K RMP-161-4K17 7U 17.3 inch Rack Mount Display Monitor Options : - DC 9~36V power input - Touchscreen - AR hardness glass Contents < Part. 1 > RMB-17W-4K 1.1 Package
More informationUser Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen
User Manual Rack Mount Display Monitor RMP-161-F17A 6U 17.3 inch Rack Mount Display Monitor Options : - AV, S-video input - Touchscreen Contents < Part. 1 > RMP-161-F17A 1.1 Package Content 1.2 Structure
More informationTELTONIKA ModemUSB/G10 User Manual v0.1
Address: Žirmūnų g. 27, Vilnius LT-09105, Tel.: +370 5 2127472, Fax: +3705 276 1380, E-mail: info@teltonika.lt TELTONIKA User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 1. ATTENTION... 3 2. FOR
More informationProducts for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.
Products for digital substations SIPROTEC 6MU805 Merging Unit for conventional instrument transformer Integrated PRP, HSR siemens.com/processbus built to create digital substations based on IEC 61850-9-2
More informationOPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM
OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM Document No. 10104401 Page 2 of 14 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION...4 1.1.1
More informationINDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide
INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationPoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide
PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters KC-351 Series Installation Guide -1- DOC.070820-KC-351 (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More information10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide
10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS KC-300DM Series Installation Guide -1- DOC.060215-KC-300D (C) 2003 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in
More informationSIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.
Products for digital substations SIPROTEC 7SC805 Merging Unit for conventional instrument transformer Integrated PRP, HSR www.siemens.com/processbus built to create digital substations based on IEC 61850-9-2
More information16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch
12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:
More informationDRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationKFC-200. Installation Guide
KFC-200 10/100BASE-TX to 100BASE-FX Media Converters Installation Guide DOC.121221-1- (C) 2011-2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or
More informationISE2016D Series Unmanaged Industrial Ethernet Switch
ISE2016D Series Unmanaged Industrial Ethernet Switch Key Features: IP40 protection class, fully enclosed metal cabinet Exceeds Industrial class III specifications Plug and play Wide operating temperature
More informationDiscontinued. 64PXL Board RGB INSTALLATION GUIDE V1.3. Cover: 64PXL Board RGB 8PXL Add-On Strip 16PXL Add-On Board
64PXL Board RGB INSTALLATION GUIDE V1.3 Cover: 64PXL Board RGB 8PXL Add-On Strip 16PXL Add-On Board CONTENT 1. INTRODUCTION 3 2. INSTALLATION 5 3. SAFETY AND OPERATION 7 4. SYSTEM CONFIGURATION 8 5. CARE
More informationOPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008
Ltd Intelligent industrial electronics Astronomical time relay REV 225 OPERATING MANUAL Quality control system on the production complies with requirements ISO 9001:2008 Dear customer, Company LTD. thanks
More informationDRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria
DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions
More informationABB Drives. User s Manual I/O Module Adapter AIMA-01
ABB Drives User s Manual I/O Module Adapter AIMA-01 I/O Module Adapter AIMA-01 User s Manual 3AFE 64661442 REV A EN EFFECTIVE: 1.12.2003 2003 ABB Oy. All Rights Reserved. 5 Safety instructions Overview
More informationSTAND ALONE MERGING UNIT (AMU)
STAND ALONE MERGING UNIT (AMU) DATASHEET (Panel mount configuration shown here) MGU010000 2017-05-05 2017 VIZIMAX Inc. All rights reserved TABLE OF CONTENT DATASHEET 2017-05-05 TABLE OF CONTENT PRODUCT
More informationDMS / DLS / VNS Recorders
Commissioning English Dallmeier DMS / DLS / VNS Recorders 00077 / Rev...0 Contents Contents Validity...2 Safety instructions...3 Requirements...4 HDD mounting...5 Mounting DMS... 6 Mounting DLS / VNS...7
More informationIndustrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.
More informationIES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v
IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire
More informationTVAC25100 TVAC25110 User manual
TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the
More informationTOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004
Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize
More informationVCL-TP, Teleprotection Equipment With Trip Counter Display Panel
VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable
More informationRDM172 Remote Display Module QUICK GUIDE
RDM172 Remote Display Module QUICK GUIDE BG0324 Rev. A2 RDM172 Remote Display Module QUICK GUIDE The RDM172 is an optional remote display for the PM172 Powermeter. It features a bright LED display (3 windows
More informationOPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE
OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10102303 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...
More informationIndustrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.
More informationKOM600/KOM600G Fiber Media Converter Hardware Installation Manual
KOM600/KOM600G Fiber Media Converter Hardware Installation Manual Kyland Technology Co., LTD. Publication Date: Dec. 2012 Version: V1.1 Customer Service Hotline: (+8610) 88796676 FAX: (+8610) 88796678
More informationHDMI Extender over Fiber
HDMI Extender over Fiber Dear Customer Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this
More informationConnector: 1 IEC plug(iec-320 C14) Current consumption:
General features of the series ControlCenter-Compact Series Interfaces Dynamic ports: The ports can be used to connect either a user module or a target module. Network connection: Power switch (RS 232):
More informationM727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide
M727xSP PoE Powered Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
More information10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS
10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS KC-300DM Series Installation Guide DOC.130923-1- (C) 2003-2013 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any
More informationBus Bar Protection Relay B-PRO 4000
Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation
More information8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual
8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...
More informationFL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.
Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationWSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL
WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller
More informationRuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter
Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX
More informationADAM Fiber Optic to RS-232/422/485 Converter
ADAM-4542+ Fiber Optic to RS-232/422/485 Converter Overview Fiber optic transmission offers the benefits of wide bandwidth, immunity to EMI/RFI interface, and secure data transmission. The ADAM-4542+ can
More informationTable of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...
Table of Contents Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction... 3 Product Features... 3 Front Panel... 3 LEDs... 3 Installation... 4 Selecting a Site for the Switch... 4 Connecting
More informationOPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE
OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10100902 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...
More informationAdvanced distribution feeder solution with integrated protection, monitoring, and control
Protection System Advanced distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions. Keep track
More informationUser Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628
User Manual TL-FO-HD 4K Optical Fiber Extender All Rights Reserved Version: TL-FO-HD_160628 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference
More informationEC700. Pulses concentrator. User instructions
EC700 Pulses concentrator User instructions Contents Hazards and warning... 3 Initial checks... 3 Introduction... 4 Jbus/Modbus Communication... 5 Installation... 6 Configuration... 9 Use... 9 Programming...
More informationUSB Ranger Fiber Optic USB 2.0 Extender. User Guide
USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,
More informationRELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS
RELAY MODULE 9974 INSTALLATION/USE INSTRUCTIONS All connections MUST be made with the electrical supply switched off and the batteries disconnected. GENERAL WARNINGS This manual is intended for technically
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationIndustrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide
Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any
More informationRS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual
RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...
More informationVCL-TP, Teleprotection Equipment
VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language
ALPHA Automated Transfer Switch Operating Manual Rev 1.21 The original of this document is drawn up in English language ATS Manual Rev 1.21 Alpha Technologies GmbH 2013 Table of Contents 1. Safety Instructions...
More informationPreface. Media Converter
Preface This manual describes how to install and use the Ethernet Media Converter with the link-fault-pass-through function. The Converter introduced here provides one channel media conversion between
More informationCopyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any
CVT4K-S Fiber Converter Document Version: V1.0.1 Document Number: NS110100433 Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted
More informationProtection, Automation, and Control System. Combine subcycle line protection with complete substation bay control
Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.
More informationOPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM
OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...
More informationKIEN2204S Industrial Ethernet Switch Hardware Installation Manual
KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationCM597 Ethernet Communication Module
Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet
More informationEL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide
EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,
More informationUser Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature
User Manual EKI-6528TI/ 6528TPI EN50155 8-port M12 Unmanaged/ PoE Switch with Wide Temperature Copyright The documentation and the software included with this product are copyrighted 2006 by Advantech
More informationConductive Level Controller
Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment
More informationPreface. To get the most out of this manual, you should have an understanding of Ethernet networking concepts. In this manual, you will find:
Preface This manual describes how to install and use the PCI Express Ethernet Adapter. This allows options of the different fiber connections (such as connector types and segment distance). To get the
More informationHardened PoE Ethernet Switch
Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description
More informationA low-cost, economical solution for distribution feeder protection
SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationKSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-
KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More information1. Safety Precautions (Read these precautions before use.)
R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More information1000M Gigabit Ethernet Media Converter with SFP Slot
1000M Gigabit Ethernet Media Converter with SFP Slot MODEL:JFMC-SFP2 For detailed inquiry please contact our sales team at: market@jfiber optic.com Description : 1000M adaptive fast Ethernet optical Media
More informationirbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant
irbx6gf www.is5com.com Intelligent 6 Port HSR/PRP Ethernet Switch IEC 61850 and IEEE 1613 Compliant Features Fully compliant with IEC 62439-3 HSR High-availability Seamless Redundancy Supports 4 x 10/100/1000Base-T(X)
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationHardened Media Converter
Quick Start Guide This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space. Physical Description
More information