Specification Sheet For electronically commutated motors
|
|
- Ashlyn Harvey
- 5 years ago
- Views:
Transcription
1 SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes a controller with integral pressure transducer, pressure tap, 24VAC stepdown transformer, along with 3 enclosure options. The SC-EFC can be used with any ECM motor to control the fan speed, and is capable of maintaining pressure at up to +/- 1 w.c. of pressure. The SC-EFC is available with either BACnet or LonWorks compatibility and can be integrated into virtually any building automation system.
2 Increased Energy Efficiency Improves energy efficiency when combined with: Motion detectors to automatically adjust a zone s occupancy mode from standby to occupied when presence is detected CO2 sensors as part of a demand-controlled ventilation strategy that adjusts the amount of fresh air intake according to the number of building occupants Light switches to control both lighting and a room s HVAC occupancy / standby mode setting Product Specifications Power Supply Input Model SC-VAV-N Points Universal hardware inputs Built-in Pressure Sensor 11-Point VAV 4 Wireless inputs Vdc Power Supply Digital (Triac) 4 outputs Universal outputs 2 1. Controller is Open-to-Wireless ready. Available when an optional Wireless Receiver is connected to the controller. Some wireless sensors may use more than on e wireless input from the controller. Voltage 24VAC/DC; ±15%; Class 2 Frequency 50/60Hz Overcurrent Protection Field replaceable fuse Fuse Type 2.0A 3.0A (for triacs when using the internal power supply) Power Consumption 10 VA typical plus all external loads 1, 85 VA max. (including powered triac outputs) 1. External loads must include the power consumption of any connected modules such as an Allure Series Communicating Sensor. Refer to the respective module s datasheet for related power consumption information. Communications Communication Bus BACnet MS/TP BACnet Profile B-ASC 1 EOL Resistor Built-in, jumper selectable Baud Rates 9600, , , or bps Addressing Dip switch or Configurable with the Allure Series Communicating Sensors 1. Refer to Distech Controls Protocol Implementation Conformity Statement for BACnet. Hardware Processor CPU Speed Memory Real Time Clock (RTC) STM32 (ARM Cortex M3) MCU, 32 bit 68 MHz 384 kb Non-volatile Flash (applications) 1 MB Non-volatile Flash (storage) 64 kb RAM Built-in Real Time Clock without battery Network time synchronization is required at each power-up cycle before the RTC become available
3 Status Indicator Subnetwork Communication Cable Connector Green LEDs: power status & LAN Tx Orange LEDs: controller status & LAN Rx RS-485 Cat 5e, 8 conductor twisted pair RJ " [180] 6.25" [159] Controller with Optional Terminal block Cover 7.7" [195] 2.7" [68] 5.7" [145] 5.2" [133] 0.5" [13] 2.6" [66] 0.5" [13] Inches Millimeters Environmental Operating Temperature 32 F to 122 F; 0 C to 50 C Storage Temperature -4 F to 122 F; -20 C to 50 C Relative Humidity 0 to 90% Non-condensing Standards and Regulations CE: Emission EN : 2007; A1:2011; Generic standards for residential, commercial and light-industrial environments Immunity EN : 2007; Generic standards for residential, commercial and light-industrial environments FCC This device complies with FCC rules part 15, subpart B, class B UL Listed (CDN & US) UL916 Energy management equipment UL 864 UL 864, 9 th Edition, UUKL Listed Smoke Control Equipment (ECB-VAV UUKL model only) 1 California State Fire Marshal Listing CSFM: :0100 (ECB-VAV UUKL model only) 1 CEC Appliance Database Appliance Efficiency Program 2 1. For detailed specifications regarding the ECB-VAV UUKL model, refer to the Distech Controls UUKL Smoke Control Design Guide. 2. California Energy Commission s Appliance Efficiency Program: The manufacturer has certified this product to the California Energy Commission in accordance with California law.
4 Specifications - On-Board Air Flow Sensor in. W.C. (0-500 Pa) Input Resolution in. W.C. ( Pa) Air Flow Accuracy > 0.05 in. W.C. (12.5 Pa) ±1.5% once calibrated through air flow > 0.05 in. W.C. (12.5 Pa) Specifications - Universal Inputs (UI) General Input Type Input Resolution Power Supply Output Contact Type Counter Type Maximum Frequency Minimum Duty Cycle 0 to 10VDC 0 to 5VDC 0 to 20mA Universal; software configurable 16-bit analog / digital converter 15VDC; maximum 80mA Dry contact Dry contact 1Hz maximum, 500milliseconds On / 500milliseconds Off 0 to 10VDC (40kΩ input impedance) 0 to 5VDC (high input impedance) 0 to 20mA 249Ω external resistor wired in parallel
5 Specifications - Universal Outputs (UO) General Output Type Output Resolution Output Protection Universal; software configurable 10-bit digital to analog Converter Built-in snubbing diode to protect against back-emf, for example when used with a 12VDC relay Output is internally protected against short circuits Load Resistance Minimum 600 Ω for 0-10VDC and 0-12VDC outputs Auto-reset fuse 0 or 12VDC (On/Off) Maximum 500 Ω for 0-20mA output Provides 24VAC over voltage protection 0 or 12VDC Source Current Maximum 20 ma at 12VDC (minimum load resistance 600 Ω) 1 1. Relays equipped with coil that consume between 20 and 35mA can be used with up to 2 Universal Outputs when the 15V Power Supply Output is de-rated to supply 50mA maximum current. PWM Thermal Actuator Management Adjustable period from 2 to 65seconds Adjustable warm up and cool down time Floating Minimum Pulse On/Off Time Drive Time Period 500milliseconds Adjustable 0 to 10VDC Voltage 0 to 10VDC linear Source Current Maximum 20 ma at 10VDC (minimum load resistance 600 Ω)
6 Specifications - Digital Output (DO) General Output Type Maximum Current per Output Power Source 0 or 24VAC (On/Off) PWM Floating Minimum Pulse On/Off Time Drive Time Period Power Source 24VAC Triac; software configurable 0.5A continuous 15% duty cycle for a 10-minute period External or internal power supply (jumper selectable) 0 or 24VAC Adjustable period from 2 to 65seconds 500milliseconds Adjustable External or internal power supply (jumper selectable)
7 Specifications - SC-TR40-B Transformer The SC-TR40-B is a 40 VA, 240/208/120 to 24 VAC transformer used in low voltage applications. The transformer is factory mounted to a 4 x 4 junction box for primary wiring. Org VAC Yel/Wht - 24 VAC Red VAC Wht VAC
8 Specifications - SC- Material: 6061T-6 Aluminum Alloy Port Connections: ¼" Brass Hose Barb Gasket Material: Neoprene Maximum Pressure: 10 PSIG Maximum Temperature: 250 C Maximum Air Flow: Unlimited Weight: 1.5 oz. (.68 kg) 2X Dia Neoprene Gasket (2) 3/32 Orifice (2.38 mm) (12.7mm) (12.7mm) (38.1mm) 3/8 Dia. Cap (9.525 mm) (6.35mm) L 1/4 Hose Barb (6.35mm) CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media.
9 SC-VAV-N Enclosure Options: NEMA 1 12 x 12 x 6 with backplate NEMA 3R (raintight) 12 x 12 x 6 with backplate No enclosure (transformer sold separately with no enclosure is selected) SC
ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.
D a t a s h e e t ECB-VAVS Overview The ECB-VAVS controllers are microprocessorbased programmable variable air volume (VAV) controllers designed to control cooling only and cooling with reheat single duct
More informationECB-203 Series BACnet B-ASC 14-Point Programmable Controllers
Datasheet ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers Overview Features & Benefits The ECB-203 Series controllers are microprocessor-based programmable controllers designed to control
More informationECB-300 Series BACnet B-AAC 18-Point Programmable Controllers
D a t a s h e e t ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers Overview The ECB-300 Series controllers are microprocessor-based programmable controllers designed to control equipment such
More informationDatasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview
Datasheet ECB-103 BACnet B-ASC 10-Point Programmable Controller Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Unit Ventilators Chilled Ceilings Improves
More informationDatasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview
Datasheet BACnet B-ASC 10-Point Programmable Controller Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Unit Ventilators Chilled Ceilings Improves
More informationECB-VAV BACnet B-ASC VAV Controller
D a t a s h e e t ECB-VAV BACnet B-ASC VAV Controller Overview The ECB-VAV Series controllers are microprocessor-based programmable variable air volume (VAV) controllers designed to control any variable
More informationDatasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview
Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling
More informationDatasheet. ECB-203 Series. 1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview
Datasheet ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers Overview Applications Meets the requirements of the following applications: Rooftop Units Fan Coil Units Chilled Ceilings Heat Pumps
More informationDatasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.
Datasheet ECB-600 and ECx-400 Series BACnet Programmable Controllers and I/O Extension Modules Overview Applications Meets the requirements of the following applications: Central Plant Air Handling Units
More informationBACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview
Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling with
More informationDatasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview
Datasheet ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers Overview Applications Meets the requirements of the following applications: Air Handling Units Chillers Boilers Cooling Towers Heat-Exchangers
More informationECB-VAVS and ECB-VAV Series
ECB-VAVS and ECB-VAV Series BACnet B-ASC VAV / VVT Controllers Overview Applications Meets the requirements of single duct VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV
More informationDatasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview
Datasheet ECB-VAV Series BACnet B-ASC Single Duct VAV / VVT Controllers Applications Meets the requirements of VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Parallel
More informationDatasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview
Datasheet BACnet B-ASC Single Duct VAV / VVT Controllers Overview Applications Meets the requirements of VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Parallel
More informationECL-VAV LONMARK Certified VAV Controller
D a t a s h e e t ECL-VAV LONMARK Certified VAV Controller Overview The ECL-VAV Series controllers are microprocessor-based programmable variable air volume (VAV) controllers designed to control any variable
More informationECL-103 LONMARK Certified 10-Point Programmable Controller
Datasheet ECL-103 LONMARK Certified 10-Point Programmable Controller Overview Features & Benefits The ECL-103 is a microprocessor-based programmable controller designed to control terminal units such as
More informationOverview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements
Datasheet Lighting and Sunblind Expansion Modules Overview Applications When connected to any compatible HVAC programmable controller, the ECx-Light/Blind expansion modules allow to control up to 8 lights
More informationOverview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.
Datasheet Lighting Expansion Modules Overview Applications On/Off lighting 1-10 V dimming lighting The Expansion Modules are microprocessor-based interfaces that extend the number of inputs and outputs
More informationECL-400 Series LONMARK Certified 24-Point Programmable Controllers
D a t a s h e e t ECL-400 Series LONMARK Certified 24-Point Programmable Controllers Overview The ECL-400 Series controllers are microprocessor-based programmable controllers designed to control various
More informationLX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules
LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules Product Bulletin LX-PRG600-11, LX-PRG610-11, LX-IOE400-0 LX-IOE410-0, LX-IOE420-0 Code No. LIT-12011854
More informationOverview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.
Datasheet Shades / Sunblinds Expansion Modules Overview Applications 100-240 VAC shades / sunblinds 24 VDC shades / sunblinds The Expansion Modules are microprocessor-based interfaces that extend the number
More informationLN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules
LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules Product Bulletin LN-PRG600-12, LN-PRG610-12, LN-IOE400-0 LN-IOE410-0, LN-IOE420-0 Code No. LIT-12011800
More informationECLYPSE Connected VAV Controller
Datasheet ECLYPSE Connected VAV Controller Overview Features & Benefits The ECLYPSE Connected VAV Controller (ECY-VAV) is designed to control any variable air volume (VAV) box. It supports BACnet/IP communication
More informationAndover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator
Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationAndover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator
Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.
More informationECLYPSE Communication Modules
Datasheet ECLYPSE Communication Modules Overview Features & Benefits Communication modules enable ECLYPSE Connected Controllers to communicate with a variety of devices. Scalable and Modular An ECY-RS485
More informationECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features
ECP-VAV Series 10-Point Single Duct VAV / VVT Free Programmable Controller Applications Designed to meet the requirements of single duct variable air volume (VAV) or variable volume according to temperature
More informationECLYPSE Communication Modules
Datasheet ECLYPSE Communication Modules Overview Features & Benefits Communication modules enable ECLYPSE Connected Controllers to communicate with a variety of devices. Scalable and Modular An ECY-RS485
More informationAllure EC-Smart-Comfort Series
Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview Features & Benefits The Allure EC-Smart-Comfort Series are versatile communicating
More informationAllure EC-Smart-Comfort Series
Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview The Allure EC-Smart-Comfort series are versatile communicating sensor which provide
More informationECLYPSE Connected Terminal Unit Controller
Datasheet ECLYPSE Connected Terminal Unit Controller Overview The ECLYPSE Connected Terminal Unit Controller is designed to control terminal units such as fan coil units, chilled beams, ceilings, and heat
More informationLONMARK Certified Powered Fan Coil Configurable Controllers. Overview
Datasheet RCL-PFC Series LONMARK Certified Powered Fan Coil Configurable Controllers Overview Applications Meets the requirements of the following applications: Fan Coil Units Unit Ventilators Chilled
More informationECLYPSE Connected System Controller
Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller is a modular and scalable platform used to control a wide range of HVAC applications.
More informationECP-PTU Series. ECP-PTU Series. 14-Point High-Voltage Programmable Power Terminal Unit Controller. Applications. Features
ECP-PTU Series 14-Point High-Voltage Programmable Power Terminal Unit Controller Applications Control of equipment such as: roof top units, fan coils, heat pumps, ventilator units, terminal units, lighting
More informationLX Series Free Programmable Controllers
Code No. LIT-1900565 Issued November 5, 2012 LX-PRG203-1, LX-PRG300-1, LX-PRG4x0-1, LX-PRG5x0-1 LX Series Free Programmable Controllers Description The LX Series Free Programmable Controllers are microprocessor-based
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications
More informationECLYPSE Connected Terminal Unit Controller
Datasheet ECLYPSE Connected Terminal Unit Controller Overview Applications The ECLYPSE Connected Terminal Unit Controller (ECY-(P)TU) is designed to control terminal units such as fan coil units, chilled
More informationECLYPSE Connected System Controller
Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller is a modular and scalable platform used to control a wide range of HVAC applications.
More informationECLYPSE Connected Equipment Controller
Datasheet ECLYPSE Connected Equipment Controller Overview Features & Benefits The ECLYPSE Connected Equipment Controller (ECY-303) is designed to satisfy the needs of a wide range of HVAC applications
More informationECLYPSE Connected System Controller
ECLYPSE Connected System Controller D a t a s h e e t Overview The ECLYPSE Connected System Controller is a modular and scalable platform that is used to control a wide range of HVAC applications. It supports
More informationBTL -listed WSP-Certified Powered Fan Coil Configurable Controllers. Overview
Datasheet BTL -listed WSP-Certified Powered Fan Coil Configurable Controllers Overview The are microprocessor-based configurable controllers designed to control a wide variety of terminal units such as
More informationBACnet. b3867 Terminal Controllers
BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product
More informationECLYPSE nlight Solution
Datasheet ECLYPSE nlight Solution nlight protocol Solution for ECLYPSE Connected System Controllers Figure 1: ECLYPSE nlight Solution shown with the power supply module, server module, and nlight communication
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,
More informationLN Series Remote Input/Output (I/O) Modules
LN Series Remote Input/Output (I/O) Modules Product Bulletin LN-IO301-1, LN-IO401-1, LN-IO520-1 Code No. LIT-12011316 Issued June 5, 2012 Supersedes November 9, 2007 The LN Series Remote Input/Output (I/O)
More informationECLYPSE Connected System
Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller (ECY-CSC) is a modular and scalable platform used to control a wide range of HVAC applications.
More informationECLYPSE Connected Terminal Unit Controller
Datasheet ECLYPSE Connected Terminal Unit Controller Overview Applications The ECLYPSE Connected Terminal Unit Controller (ECY-TU/PTU) is designed to control terminal units such as fan coil units, chilled
More informationSiemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control
Technical Specification Sheet Document No. 149-844 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control Returns from power failure without operator intervention.
More informationLONMARK Certified 24-Point Programmable Controllers. Overview
Applications Meets the requirements of the following applications: Air Handling Units Multi-Zone Applications Chillers Boilers Cooling Towers Roof Top Units Improves energy efficiency when combined with:
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationBACnet. b3810 Series Local Controllers
BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationInput/Output Module (IOM) Series Catalog Page
Input/Output Module () Series Catalog Page Johnson Controls www.johnsoncontrols.com LIT-1900349 2018-12-17 Input/Output Module () The Series expansion I/O modules have integral RS-485 MS/TP communications
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationTALON Network Manager- 2 & 6 Express
Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform
More informationAirflow Pressure Sensor
Desigo TRA Airflow Pressure Sensor DXA.S04P1... Airflow Pressure Sensor (APS) is used to measure airflow for room pressurization and fume hood control applications. Differential Pressure (velocity) is
More informationLonMark Certified 10-Point Programmable Controller. Overview
Datasheet LonMark Certified 10-Point Programmable Controller Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Unit Ventilators Chilled Ceilings Improves
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationRXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications
s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems
More informationHARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide
HARDWARE GUIDE VAV Zone Controller C1000 Series Specifications and Operational Guide www.proloncontrols.com info@proloncontrols.com 17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV. 6.1.6 PL-HRDW-VAV-C1000-C/F-EN
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationclarity 3 Programmable Controller
clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More informationFX Input/Output (I/O) Modules XM07 and XM14
Product Bulletin FX I/O Modules Issue Date July 6, 2009 FX Input/Output (I/O) Modules XM07 and XM14 The FX Input/Output (I/O) Modules provide additional physical input and output points for FX field controllers
More informationSiemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller
Technical Specification Sheet Document No. 149-834 August 23, 2010 Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller The Siemens BACnet PTEC VAV with Series Fan and
More informationProgrammable controller MCX06C
MAKING MODERN LIVING POSSIBLE Technical brochure Programmable controller MCX06C Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best
More informationisma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland
isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4
More informationFX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015
Expansion Input/Output Modules Catalog Page Code No. LIT-1900671 Issued April 17, 015 The s are expansion I/O modules with integral RS-5 MS/TP communications. Note: At FX-PCT Release 10.1, FX-PCVs, FX-PCGs,
More informationAIAS. Technical description
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -
More informationSiemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller
Technical Specification Sheet Document No. 149-851 August 12, 2011 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides high
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationMOD-IO9 Modbus Input / Output Modules, Wall Mounted
Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module
More informationLonMark Certified 18-Point Programmable Controllers. Overview
Datasheet LonMark Certified 18-Point Programmable Controllers Overview Applications Meets the requirements of the following applications: Air Handling Units Chillers Boilers Cooling Towers Heat Exchangers
More informationSuitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.
TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with
More informationLX Series Remote Input/Output (I/O) Controller
LX Series Remote Input/Output (I/O) Controller Product Bulletin LX-IO520-1, LX-IO401-1, LX-IO301-1 Code No. LIT-12011491 Issued June 22, 2009 The LX Series Remote Input/Output (I/O) controller extends
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationThe Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box
Infinity TCX 865,866 VAV Controller with Built-in Actuator The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box controller that comes equipped with a built-in damper
More informationLN Application Specific, Remote I/O, and Free Programmable Controllers
LN Application Specific, Remote I/O, and Free Programmable Controllers Installation Instructions LN-RTUL-1, LN-FCUL-1, LN-UVL-1, LN-HPUL-1, LN-IOxxx-1, LN-PRG203-2, LN-PRG300-2, LN-PRG4x0-2, LN-PRG5x0-2
More informationLONMARK Certified 28-Point Programmable Controllers. Overview
Datasheet LONMARK Certified 28-Point Programmable Controllers Applications Meets the requirements of the following applications: Air Handling Units Multi-Zone Applications Chillers Boilers Cooling Towers
More informationSmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationSiemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller
Technical Specification Sheet Document No. 149-851 September 24, 2014 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides
More informationclarity 3 VAV Programmable Controller
clarity 3 VAV Programmable Controller BACnet VAV Controller-Actuators (B-AAC) DESCRIPTION Taco Clarity3 series controller-actuators are designed to operate VAV (Variable Air Volume) terminal units. The
More informationTC-9102 Terminal Controller
Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 1095 TC-9102 Terminal Controller The TC-9102 Terminal Controller, the latest addition to the
More informationFXVMA Variable Air Volume (VAV) Box Controller
FXVMA Product Bulletin FXVMA Issue Date November 21, 2008 FXVMA Variable Air Volume (VAV) Box Controller The FXVMA is an integrated assembly used to control Variable Air Volume (VAV) boxes. The FXVMA consists
More informationHardware Installation Guide
Hardware Installation Guide IO Extension Module for ECL600 and ECB600 Series Controllers: 1. Product Description This document describes the hardware installation procedures for the I/O Extension Modules.
More informationSiemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller
Technical Specification Sheet Document No. 149-831 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller No calibration required, thereby reducing maintenance costs. PID
More informationSiemens BACnet Programmable TEC Unit Vent Controller for Smoke Control
Technical Specification Sheet Document No. 149-841 August 12, 2011 Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control The Siemens BACnet PTEC Unit Vent Controller provides high performance
More informationIQ21x Series Controllers
IQ1x Series Controllers IQ1x SERIES CONTROLLERS Description Features The IQ1x series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility
More informationSE8300 Room Controller
SE8300 Room Controller Low Voltage Fan Coil Controller and Zone Controller Application Specific low voltage Room Controller with customizable covers and screen colors. Suitable for commercial and high
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationViconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification
Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated
More informationField selectable application type and room module series, via dip-switches on controller
TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the
More informationSmart Equipment Controls (SEC)
Smart Equipment Controls (SEC) Product Bulletin SE-SPU1001-0, SE-SPU1002-0, SE-SPU1011-0, SE-SPU1011-0, SE-SPU1012-0, SE-SPU1004-0, SE-FDD1001-0, SE-ECO1001-0, SE-COM1001-0 Code No. LIT-12011934 Issued
More informationSiemens BACnet Programmable TEC Unit Conditioner Controller
Technical Specification Sheet Document No. 149-831 September 24, 2014 Siemens BACnet Programmable TEC Unit Conditioner Controller Returns from power failure without operator intervention. No calibration
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationSLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)
SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500
More informationLN Series Free Programmable LN-PRGxxx-12 Controllers
LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions LN-PRG203-12, LN-PRG300-12, LN-PRG4x0-12, LN-PRG6x0-12 Code No. LIT-12011796 Issued April 24, 2014 Supersedes January 30,
More information