INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card"

Transcription

1 INSTALLATION INSTRUCTIONS Model VCC2002-A Voice input/output Card The Model VCC2002-A Voice I/O card is installed into the FV2025/2050 Fire Voice Control Panel of the FS20 system. Together with the VCC200-A Voice CPU card and one or more VCI200-U Amplifier cards, it enables voice announcements to be made through the Fire/Voice system. FEATURES The principal features of the VCC2002-A include: The internal codec: o o Converts analog audio from microphones, Mass Notification Systems (MNS), Global Management Systems (Desigo CC) and other external sources into digital audio signals Converts digital audio signals to analog for use in other parts of the system or with external equipment Attenuation and amplification of incoming audio Connections for optional remote microphones and voice switch modules CAN repeater for externally connected modules Connections for two (2) configurable, simultaneous audio input channels and two (2) audio output channels, internal and external 24VDC power distribution, current limiting, and short circuit protection for modules connected to the Card Cage Operational status via LED displays Two volume controls EMC compliant ROHS compliant and meets performance specifications within the industrial temperature range Can be used in the UL and ULC market Figure VCC2002-A Voice I/O Card PRE-INSTALLATION Before installing the VCC2002-A Voice I/O Card into the VCA2002-A Card Cage, set the jumpers on the card to either supervise or not supervise the input and output audio lines. Supervision refers to the automatic monitoring of signal lines for short or open circuit conditions. A supervised line will have an endof-line (EOL) resistor at the end of the line to set a DC bias level. When the resistor is present, the DC voltage is at a certain value. This DC voltage level will change if the line is either open-circuited or shorted. This DC bias voltage is monitored by an analog-to-digital converter which enables the system to read all the voltage levels and determine if a short or open has occurred. Figure 2 illustrates the locations of the jumpers on the Voice I/O Card and Table lists the jumper settings that are used to activate supervision for the input and output channels. Both jumpers for each channel must be in the same position, either supervised or unsupervised, for the card to operate correctly. A6V097774_en--_a

2 X40 X400 X40 X402 X60 X600 Example : Supervision Selected for All Channels X40 X400 X40 X402 X60 X600 Figure 2 Jumpers on VCC2002-A voice I/O Card Example 2: All Channels Unsupervised Channel Jumper ID Jumper Position for Supervised Channel Jumper Position for Unsupervised Channel Audio Input X X Audio Input 2 X X Audio Output X X Table Jumper Settings on VCC2002-A Voice-I/O Card for Supervised Channel Operation A6V097774_en--_a 2

3 CAUTION: If supervised audio input lines are to be implemented, ensure that any connected audio equipment is compatible with the 8VDC supervision voltage. OPERATION Please refer to Figure. The primary functions of the VCC2002-A Voice I/O Card are to: Interface with the VTO2004-U2/U Option Module (Microphone) and the VTO200-U2/U Option Module (24 Switches), if applicable, and other external devices, such as CD players. Provide analog/digital conversion of announcements routed to the VCC200-A Voice CPU Card Provide digital/analog conversion of announcements routed from the VCC200-A to the external announcement sources. Distribute and supervise 24VDC power Provide DC supervision of external wiring Provide a CAN bus repeater functionality VTO2004 OPTION MODULE (MICROPHONE) INTERNAL AUDIO IN X02 X0 +24 VOLT DC INPUT TO MNS, EXTERNAL OPTION MODULES OR OTHER AUDIO DEVICES OPTION MODULES (FUTURE) CH IN CH 2 IN CH OUT INTERNAL AUDIO OUT X40 X402 X40 X02 AUDIO HANDLING 24VDC POWER DISTRIB. X40 X402 X02 EXTERNAL OPTION MODULES INTERNAL OPTION MODULES TO / FROM VCC200-A VOICE CPU CARD DIGITAL AUDIO OUT DIGITAL AUDIO IN CODEC AUDIO ACTIVITY INPUTS/ OUTPUTS X40 X40 X40 CH IN CH 2 IN CH OUT EXTERNAL DEVICES TO EXTERNAL OPTION MODULES X40 CAN BUS CPLD CAN REPEATER I2C BUS CAN BUS TO / FROM VCC200- A VOICE CPU CARD TO INTERNAL OPTION MODULES X02 CAN BUS Figure VCC2002-A Voice I/O Card Signal Flow Diagram A6V097774_en--_a

4 Controls and Indicators The VCC2002-A VCC I/O Card contains: two audio level controls for Input and/or Input 2 eight diagnostic LEDs one Power LED All of these controls and indicators are located along the card edge and visible through the Card Cage front cover. NOTE: The audio level control does not affect audio levels that originate from external microphones. Adjust the audio input levels on Input and/or Input 2 by inserting a small screwdriver through the proper opening on the front panel and turning it clockwise to increase, or counter-clockwise to reduce the level. Table 2 defines the functions of the nine LEDs. Audio Activity Inputs/Outputs Contact closure inputs and outputs are available to/from the VCC-I/O card. They are used to indicate the presence of an external analog audio signal on the inputs to Channels or 2 and that the output audio from the system is active. Input. One set of contacts must be provided by each external audio source that is connected to either the Channel or 2 input to indicate when an analog audio output is applied to the channel. A closed contact indicates that the audio input to the channel is active while an open contact means that the audio input is inactive. Output. A relay contact on the VCC-I/O card closes to indicate to external devices that the audio output is active. When the audio output is inactive, the relay contact is open. This is an isolated contact. The external connection must supply its own voltage to determine the state of the relay contact. LED ID COLOR NORMAL STATE ACTIVE STATE FAULT CONDITION DESCRIPTION Input Active Green Off On Channel Active Input Fault Yellow Off On Channel Fault Input 2 Active Green Off On Channel 2 Active Input 2 Fault Yellow Off On Channel 2 Fault Audio Out Active Green Off On Audio Output Active Audio Out Fail Yellow Off On Audio Output Fault 24V-CAN Fail Yellow Off On 24V or CAN Bus Fault Card Fail Yellow Off On Card failure Power Green On Off +.VDC Power Figure 4 VCC202-A Indicator LEDs Table 2 VCC202-A Indicator LED States and Meaning A6V097774_en--_a 4

5 MOUNTING Remove electrical power prior to working on equipment. To mount the VCC-I/O in the card cage:. Open the inner door of the FV2025/2050 Fire Voice Control Panel. 2. Unscrew the latch on the center-bottom of the Card Cage front cover and slide the cover up until it clears the Card Cage assembly. VOLUME CONTROL POTENTIOMETERS CARD HANDLE Figure 5 VCC2002-A Voice I/O Card Showing Handle and Volume Controls. Please refer to Figure 5. Holding the VCC2002-A so the two volume control potentiometers are on top of the card, gently insert the card into the backplane connector marked X20 (furthest left position of the card cage). Use the raised channel guides on the inside top and bottom of the Card Cage to guide it into place. CAUTION When inserting the VCC2002-A into the backplane connector, avoid using the top and bottom of the card cage for leverage. Instead, push gently on the center of the molded plastic card handle until the card snaps into place. Be sure that the card is perpendicular to the front of the Card Cage and is positioned between the two indented metal cards guides in the top and bottom of the Card Cage. The card needs to be between all three sets of card guides as it is slid into place to correctly mate with the backplane connector. WARNING To avoid damaging the VCC2002-A card or the backplane connector, DO NOT FORCE THE CARD INTO POSITION. 4. Replace the Card Cage cover by re-inserting it into the top of the cage and sliding it downward until it reaches the bottom of the assembly. 5. Screw the latch back into the Card Cage cover. A6V097774_en--_a 5

6 Removing the Voice I/O Card from the Card Cage. First remove power from the Card Cage. 2. Unscrew the latch on the center-bottom of the VCA2002-A Card Cage front cover and slide the cover up.. Grip the VCC200-A Card by the molded plastic card handle and pull the card gently out of the backplane connector. 4. Replace the Card Cage cover and reinsert the latch. WIRING The audio input and output activity signals from/to external audio devices are connected to the VCC-I/O card through Connector X40 on the VCA2002-A Card Cage. The pin functions for this connector are listed in Table 2 of Siemens Industry, Inc., Building Technologies Division, document number A6V Installation Instructions for the Model VCA2002-A Card Cage. Terminating resistors Install.K ohm terminating resistors onto terminals of the Voice I/O Card Field Connector, X40, which is located on top center of the Card Cage backplane as follows: X40 Pin Function Terminating Resistor* Audio Out+.K Ohm 2 Audio Out- Audio Out Active Ch+ 4 Audio Out Active Ch- C2425-A-K4 5 Audio In Active Ch+.K Ohm 6 Audio In Active Ch- C2425-A-K4 7 Audio In Active Ch2+.K Ohm 8 Audio In Active Ch2- C2425-A-K4 9 External Alarm+.K Ohm 0 External Alarm- C2425-A-K4 *All terminating resistors are provided in the A5Q Accessory Kit furnished with the VCA2002-A Card Cage. A6V097774_en--_a 6

7 ELECTRICAL RATINGS VCC2002-A Voice I/O Card Card Input Voltage 24VDC,. VDC Output (X40 on Card Cage) Output 2 (X402 on Card Cage) Voltage Current Voltage Current 24VDC 5 ma, max* Special application for use with VTA200 Power limited 24VDC 56 ma max* Special application for use with VTA200 Power limited *NOTE: The 4A is shared between X40 and X402. The maximum combined load for both outputs must not exceed 4A when connecting devices on X40 and X402. A6V097774_en--_a 7

8 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK Siemens Industry, Inc. Siemens Canada Limited Document ID: A6V097774_en--_a Building Technologies Division Building Technologies Division P/N: A5Q Florham Park, NJ 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada A6V097774_en--_a 8

INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches)

INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches) INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches) The Model VTO2001-U2/U3 Option Module (24 Switches) illustrated in Figure 1 is installed in the FV2025/2050 Fire Voice Control

More information

INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage

INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage The Model VCA2002-A1 Card Cage assembly is installed in the FV2025/2050, FV922/FV924 Fire Voice Control Panel of the FS20 system to house and interconnect

More information

Installation Instructions Model LPB

Installation Instructions Model LPB Installation Instructions Model LPB Local Page Board (500-035200 / S24235-B5-A2) INTRODUCTION The LPB (Local Page Board) is used to connect the alarm microphone, mounted in the LVM (Live Voice Microphone),

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

Installation Instructions Model ZAM-180

Installation Instructions Model ZAM-180 s Installation Instructions Model ZAM-80 Zone Amplifier Module 80W (500-035600 / S24235-B6-A5 (70V)) Installation Instructions for North America INTRODUCTION The Model ZAM-80 from Siemens Industry, Inc.

More information

Installation Instructions Models CC-5 / CC-2

Installation Instructions Models CC-5 / CC-2 Installation Instructions Models CC-5 / CC-2 System Cardcage CC-5 (500-633037 / S24235-B123-A1) System Cardcage CC-2 (500-633440 / S24235-B122-A1) INTRODUCTION The SIEMENS Model CC-5 Cardcage (see Figure

More information

Installation Instructions Model PSC-17C

Installation Instructions Model PSC-17C Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem

More information

Figure 50. LED through-board connectors and guide marks

Figure 50. LED through-board connectors and guide marks 5.6.3 Installing the LED Lamp Boards on the IP Room Controller Board On the back side of the IP room controller PCB there are the four sets of through-board connections for the LED lamp boards. Each through-board

More information

Installation Instructions Model SNC Serial Network Card for USB Application with Windows

Installation Instructions Model SNC Serial Network Card for USB Application with Windows Installation Instructions Model SNC Serial Network Card for USB Application with Windows OPERATION The Model SNC from Siemens Industry, Inc. (as shown in Figure 1) is a USB-compliant network card used

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

Installation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB

Installation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB Installation Instructions Models FCM- / LCM- / SCM- Model CSB Control Module / LED Control Module / Switch Control Module CAN Sounder Board INTRODUCTION The Models FCM-, LCM- and SCM- from, are similar

More information

MXL / MXLV Rack-Mount Fire-Alarm Equipment

MXL / MXLV Rack-Mount Fire-Alarm Equipment s Data Sheet Fire Safety & Security Products MXL / MXLV Rack-Mount Fire-Alarm Equipment Models: ACM-RK, CABLES-RK, MKB-3, MKB-RK, MMB-RK, MOM-RK, MPS-RK, MXL-RK1, TSP-RK, and VSM-RK ARCHITECT AND ENGINEER

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Installation Instructions Model PSX-12

Installation Instructions Model PSX-12 Installation Instructions Model PSX- Amp Power Supply Extender INTRODUCTI The SIEMENS Model PSX- is a high current power supply extender. The power supply extender works in conjunction with the PSC- power

More information

Cube67 - Modular I/O station

Cube67 - Modular I/O station Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic

More information

TitanONE Smart Mainframe Power Amplifier

TitanONE Smart Mainframe Power Amplifier 1/7 TitanONE Smart Mainframe Power Amplifier T112 General Description The AtlasIED TitanONE T112 Smart Mainframe Power Amplifier provides the latest signal automation, processing and amplification technologies

More information

Discrete Output Modules IC697MDL740

Discrete Output Modules IC697MDL740 55 1 IC697MDL740 (IC697MDL740) datasheet Features 16 Points - Four isolated groups of 4 points each 2 amp capacity per point High inrush capacity (10x rated current) Functions The 24/48 Volt DC 2 Amp Output

More information

Discrete Output Modules IC697MDL750

Discrete Output Modules IC697MDL750 54 IC697MDL750 (IC697MDL750) datasheet Features 32 Points - Four isolated groups of 8 points each a44709 0.5 amp capacity per point High inrush capacity (20x rated current) Functions The 24/48 Volt DC

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal

More information

Discrete Input Modules IC697MDL653

Discrete Input Modules IC697MDL653 43 1 I97MDL653 24 Volt Positive/Negative Logic, 32-Point Input Module 24 Volt Positive/Negative Logic, 32-Point Input Module (I97MDL653) datasheet Features a44082 32 Points - Four isolated groups of 8

More information

MXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3

MXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3 MXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3 Standard 19 Rack Mounting for MXL and MXLV System Modules Rack Mount

More information

Audio Input Card Installation Instructions

Audio Input Card Installation Instructions Installation Instructions Introduction This publication describes the installation procedure for the 4100-1240. This card is compatible with 4100U and 4100ES Fire Alarm Control Panels. In this Publication

More information

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual 5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions ACTIONI/Q Q498 DC Powered DC Input Field Configurable Isolator with Math Functions Q498-0000 Provides 2 Isolated Analog Inputs, 1 Analog Output & 1 Frequency Output, as well as a Discrete Input & Output

More information

TITLE: Field adjusting EECO 1000/2000/3000 Power Supply and Printer Mechanism Print Density

TITLE: Field adjusting EECO 1000/2000/3000 Power Supply and Printer Mechanism Print Density TITLE: Field adjusting EECO 1000/2000/3000 Power Supply and Printer Mechanism Print Density TechNote: 000221 Symptom: EECO Power Supply output voltages too low and print density too high, results in intermittent

More information

Figure 36. Connecting the 24V/DC power supply

Figure 36. Connecting the 24V/DC power supply 5.5.1 Connecting the 24Vdc Power Supply The 24Vdc power supply uses a 2-pole connection terminal as described in section 5.4.2 on page 33. The connection point on the room controller circuit board for

More information

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module March 2002 Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module Features 32 Points - Four isolated groups of eight points each 0.5 amp capacity per point High inrush capacity

More information

Installation Instructions

Installation Instructions Installation Instructions Model PAL- Parallel Printer Operation The model PAL- from Siemens Industry, Inc. allows the connection of an ITE Centronics parallel printer to the Siemens FireFinder- XLS, MXL,

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Installation Instructions Model FMT

Installation Instructions Model FMT Installation Instructions Model FMT Fireman s Master Telephone ITRODUCTI The Model FMT Fireman s Master Telephone from Siemens Industry, Inc. provides firefighters with an emergency telephone system for

More information

EDUCATION EXPERIENCES WITH A USB INTERFACE

EDUCATION EXPERIENCES WITH A USB INTERFACE Practice and Theory in Systems of Education, Volume 4 Number 1 2009 EDUCATION EXPERIENCES WITH A USB INTERFACE József NEMES (University of West-Hungary, Szombathely, Hungary) njozsef@ttmk.nyme.hu On the

More information

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual 550 Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676 Canada -CONTROL

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

MXL / MXLV Enclosures & Equipment

MXL / MXLV Enclosures & Equipment s Data Sheet Fire Safety & Security Products MXL / MXLV Enclosures & Equipment Models: MME-3, MBR-MP,, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4u ARCHITECT AND ENGINEER SPECIFICATIONS MME-3

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs. This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the

More information

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual 550 Differential Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0

More information

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines

More information

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual 550 Thermocouple Analog Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver INSTALLATION INSTRUCTIONS MicroComm DXI Fiber Station Transceiver. Intent & Scope This document describes the installation procedure for the Fiber Station Transceivers. 2. Description The Fiber Station

More information

TruPortal Output Expansion Board Quick Reference

TruPortal Output Expansion Board Quick Reference TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.qualitrol.com/shop/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0 module.

More information

IC693PWR331 High Capacity Power Supply, 24 VDC Input

IC693PWR331 High Capacity Power Supply, 24 VDC Input IC693PWR331 High Capacity Power Supply, 24 VDC Input The Series 90-30 DC input High Capacity power supply (IC693PWR33) is a 30 watt wide range supply designed for 24 VDC nominal inputs. For applications

More information

ICP-SDI Installation Instructions. SDI Splitter

ICP-SDI Installation Instructions. SDI Splitter ICP-SDI-9114 EN Installation Instructions SDI Splitter ICP-SDI-9114 Installation Instructions Listings and Approvals Listings and Approvals UL UL 65 Police Station Burglar Alarm Units and Systems UL 609

More information

V-9908 MESSAGE/PAGE PANEL

V-9908 MESSAGE/PAGE PANEL Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides

More information

Advantages of a Full Featured 700 Series Relay

Advantages of a Full Featured 700 Series Relay SECTION 1 Advantages of a Full Featured 700 Series Relay Since the launch of the 700 series relays in 2000, this product line has continuously evolved both functionally and visually. The 700 series product

More information

OPMM-1616-XT. PC/104 I/O Module with Optoisolated inputs and Relay Outputs. Rev 1.0 September 2010

OPMM-1616-XT. PC/104 I/O Module with Optoisolated inputs and Relay Outputs. Rev 1.0 September 2010 init OPMM-1616-XT PC/104 I/O Module with Optoisolated inputs and Relay Outputs Rev 1.0 September 2010 Revision Date Comment 1.0 9/26/2010 first release FOR TECHNICAL SUPPORT PLEASE CONTACT: Copyright 2010

More information

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Catalog Number Identification with Elements Explained V V V V X 347 V Hz Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of

More information

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note *44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

Peristaltic Cased Tube Pump

Peristaltic Cased Tube Pump Peristaltic Cased Tube Pump Selectable Output Control Functionality and Setup Version 1.0v-11/2016 Print-No. 01 Table of Contents 1. Introduction 2. Powering the Input/Output Port 2.1 Wiring for Local

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements installing the module connecting the wiring using the indicators for

More information

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module MTAC-01 Pulse Encoder Interface Module MTAC-01 User s Manual 3AFE68591091 REV B EN EFFECTIVE: 04.04.2006 2006 ABB Oy. All Rights Reserved. 5 Safety

More information

User s Manual Pulse Encoder Interface Module OTAC-01

User s Manual Pulse Encoder Interface Module OTAC-01 Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01 N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO-120802LN-USB This product is a USB2.0-compliant analog I/O unit that extends the analog I/O function of USB port of PCs. Compact design

More information

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web TM 9109 FXS Analog Voice Application Module (APM) Installation Instructions Document Number 9109-A2-GN12-40 May 1999 Product Documentation on the World Wide Web We provide complete product documentation

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

PACSystems* RX3i IC694ALG233

PACSystems* RX3i IC694ALG233 November 2015 PACSystems* RX3i IC694ALG233 Advanced Diagnostics Analog Current Input Module 16 Channel The PACSystems* RX3i 16-Channel Analog Current Input module provides 16 single-ended input channels.

More information

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module) Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

SERIES SIX PROGRAMMABLE CONTROLLERS

SERIES SIX PROGRAMMABLE CONTROLLERS SERIES SIX PROGRAMMABLE CONTROLLERS 125 V DC INPUT CPU POWER SUPPLY MODULE GFK-0065 Source Voltage 100 to 150 V dc Output Voltage +5, +12, -12 V dc GENERAL DESCRIPTION The 125 V dc Input CPU Power Supply

More information

Pre-Laboratory #Boolean Expressions ECE 332

Pre-Laboratory #Boolean Expressions ECE 332 Name: G Number: Pre-Laboratory #Boolean Expressions ECE 332 1 Introduction This pre-lab is divided into two parts. In part one you will build a circuit for providing inputs to your CPLD board on your breadboard.

More information

RS232 Control Box. Table of contents

RS232 Control Box. Table of contents Control Box Table of contents Page Introduction... Installation...5 Mounting the box System cable External power supply Location of switches and connectors Internal switch settings...8 Possible configurations...9

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

Branch PLC. Velocio s Branch PLC

Branch PLC. Velocio s Branch PLC Velocio s Branch PLC Branch PLC The Branch PLC is a member of the Velocio s groundbreaking series of programmable logic controllers. These PLCs introduce revolutionary new concepts, capabilities, performance

More information

User's Manual. DADS-MB701 In Vehicle Automatic Announcement System. Version 1.1, Revised 19, January Doc

User's Manual. DADS-MB701 In Vehicle Automatic Announcement System. Version 1.1, Revised 19, January Doc DADS-MB701 In Vehicle Automatic Announcement System User's Manual Version 1.1, Revised 19, January 2016 Doc 99-20-087 2 1. Table Of Contents 1. Table Of Contents... 2 2. Overview:... 3 3. DADS-MB701 Installation...

More information

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V. This Datasheet for the IC670ALG310 Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V http://www.qualitrol.com/shop/p-14493-ic670alg310.aspx Provides the wiring diagrams and installation guidelines for

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Signal Adapter. Signal Output. Power Input. Modell-Zug Elektronix Signal Adapter U.S.A. Momentary. Auxillary. Switch. Outputs

Signal Adapter. Signal Output. Power Input. Modell-Zug Elektronix Signal Adapter U.S.A. Momentary. Auxillary. Switch. Outputs Adapter 1. Introduction Thank you for purchasing this product. The Adapter was specially designed to provide universal operation of the new generation of Märklin color light signals 74371, 74380, and 74391.

More information

CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM, OD-LP, OD-BP, OD-GP, REMBOX2, REMBOX4, XLS-MLE6-ADPT,

CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM, OD-LP, OD-BP, OD-GP, REMBOX2, REMBOX4, XLS-MLE6-ADPT, Data Sheet Fire Safety & Security Products s FireFinder TM XLS Fire Alarm Enclosures & Equipment Models: CAB1, CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM,

More information

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power September 2013 PACSystems* RX3i Isolated Analog Output Module, IC695ALG808-EA Isolated Analog Voltage/Current Output module IC695ALG808 provides eight configurable voltage or current output channels. Analog

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

User's Manual. USB 2.0 Audio PCA with 16 Bit I/O, 4 x 4 Audio Mixer

User's Manual. USB 2.0 Audio PCA with 16 Bit I/O, 4 x 4 Audio Mixer User's Manual USB 2.0 Audio PCA with 16 Bit I/O, 4 x 4 Audio Mixer Part No: 10516 Revision: A Date: 16SEP10 emdee Technology, Inc. www.emdee.com Table of Contents 1.0 Overview... 3 1.1 Block Diagram...

More information

B&R X67_IO_System_V3.14_E. X67 - System

B&R X67_IO_System_V3.14_E. X67 - System B&R X67_IO_System_V3.14_E X67 - System X67 I/O System - Benefits to the User Why I/Os in the IP67? Potential of the remote machine concept Cost reduction with remote I/O concept Reduced wiring Minimization

More information

Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC

Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC May 2017 PACSystems* RX3i Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC Non-Isolated Analog Voltage/Current

More information

PCM ch Isolated Digital I/O Module. User Manual

PCM ch Isolated Digital I/O Module. User Manual PCM-3730 32-ch Isolated Digital I/O Module User Manual Copyright The documentation and the software included with this product are copyrighted 2005 by Advantech Co., Ltd. All rights are reserved. Advantech

More information

BENCHMARK MEDIA SYSTEMS, INC.

BENCHMARK MEDIA SYSTEMS, INC. BENCHMARK MEDIA SYSTEMS, INC. RLY-106 Instruction Manual 1.0 Introduction...1 2.0 Input and Output Connections...1 2.1 Connection Alternatives...2 3.0 Relay Ratings...2 4.0 Applications...4 4.1 Audio Signal

More information

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features: DIGITAL DISPLAY for Industry Applications Series PAXD Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Plug-In Cards...4 Programming & Software...5 Order Code & Accessories...6-5

More information

2562 QUICK START GUIDE

2562 QUICK START GUIDE 2562 QUICK START GUIDE CTI P/Ns: 2562 Quick Start Guide: 062-00348-010 2562 Installation and Operation Guide: 062-00332-011 Summary: The 2562 is designed to translate a digital word from the programmable

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

GE Fanuc IC694ALG221. Rx3i PacSystem

GE Fanuc IC694ALG221. Rx3i PacSystem GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

Analog Interface Unit Operation Manual

Analog Interface Unit Operation Manual Analog Interface Analog Interface Unit Operation Manual WARRANTY Accurate Technology, Inc. warrants the product against defective parts and workmanship for 1 year commencing from the date of original purchase.

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured

More information

Comm. RS-232. Analog I/O I N P U T S O U T P U T S. I/O Supply. Logic Supply RET RET Fault

Comm. RS-232. Analog I/O I N P U T S O U T P U T S. I/O Supply. Logic Supply RET RET Fault Model 2220 Analog Input / Output Module Installation Guide 2701E 2203 I/O Supply Logic Supply Fault 1 5 9 13 I N P U T S 2220 Digital Out 02 04 06 08 RET RET +24 +24 Out1 Out4 Out5 Out8 Comm. RS-232 1

More information

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL Copyright 1997-2005, Audio Technologies Incorporated - Printed in USA DESCRIPTION Your L200 Dual Line/Buffer Amplifier is an inexpensive, high

More information

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels. This Datasheet for the IC660BBA101 Block 115Vac/125Vdc RTD Input 6 Channels http://www.qualitrol.com/shop/p-14423-ic660bba101.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Keystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions

Keystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Index 1. Optional module 1: Modulating I/O module... 1 2. Installation... 2 3. OM1 card setting and configuration... 6 4. Monitor

More information

Technical Manual SMART TRAC DM6420 Multi I/O Card

Technical Manual SMART TRAC DM6420 Multi I/O Card Technical Manual SMART TRAC DM6420 Multi I/O Card SMART TRAC DM6420 Multi I/O Card Contents Important Safety and Warranty Information 1 Warnings, Cautions and Notes...1 General Safety Precautions - Warnings...2

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE WARNINGS 1. All servicing should be performed by qualified service personnel. 2. WARNING, Battery may explode if mistreated. Do not recharge, disassemble

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Chassis Power Supplies

Chassis Power Supplies PDC24 / PAC Chassis Power Supplies (PDC24 / PAC) Issue 3 October 2005 INTRODUCTION PURPOSE Two Power Supply Units (PSUs) provide a dual-redundant source of 5.4Vand 12Vdc onto the backplane for the modules

More information