Manual Industry Interfaces

Size: px
Start display at page:

Download "Manual Industry Interfaces"

Transcription

1 Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0

2 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should be used without checking. Please let us know of any mistakes or misunderstandings you are aware of, so that we can recognize and eliminate them quickly. Perform work on and with W&T products only as described here and only if you have read and understood the manual fully. Unauthorized use can result in hazards. We are not liable for the consequences of unauthorized use. When in doubt, check with us or consult you dealer! 0

3 Industry Interfaces Wiesemann & Theis offers with their Industry Interfaces a complete family of interface converters suitable for top hat rail mounting and powered by the V supply commonly used in industrial environments. Trouble-free, noise-immune operation of the associated components is ensured by integrated galvanic isolation between the two interfaces used as well as between the power supply and the interfaces. This interface family is described on the following pages along with the corresponding technical data and including connection examples. For up-to-date information on new developments, see our Internet site at or check the short notices at the W&T Interface Club, which you can also subscribe to from the W&T Homepage. Subject to error and alteration

4 Industry Interfaces Index General Characteristics and Important Notes... RS <> 0mA Converter, Model 0... RS <> RS/RS Converter, Model 0... RS <> RS/RS Converter with OVP, Model mA <> RS/RS Converter, Model 0... RS Isolator, Model 0... RS/RS Isolator, Model 0... RS/RS Isolator with OVP, Model 0... RS Line Driver Set, Model 00...

5 Industry Interfaces General Charateristics and Important Notes Housing and setting the DIL switches All W&T Industry Interfaces are integrated into a plastic housing for mounting on DIN rails (DIN EN 00-). Some Interface models have DIL switches inside the housing. To set these switches, you must open up the housing. We recommend screwing a SUB-D plug with body onto the Interface and using the plug to help pull the housing cover out of the housing body. Display elements The interface converters feature two LED s, with the Power LED indicating correct supply voltage and the Data LED data communication in both directions. Power Supply The W&T Industry Interfaces in DIN rail housing have a broadrange supply voltage input and can be powered either by a suitable W&T power supply or with an external voltage of between and V AC or DC. The power supply must in any case ensure reliable isolation of the low-voltage side from the mains in accordance with EN00. The supply voltage feed is reverse polarity protected and is accomplished using the included plug-in screw terminal. Subject to error and alteration

6 Industry Interfaces Galvanic isolation and ESD protection Both ports of all W&T Interface Converters are isolated from each other and from the power supply with a dielectric strength of 000 volts DC. The signals are isolated by means of high-speed optocouplers; energy is supplied to the driver and receiver elements by means of an isolated DC/DC converter. All signal lines of the interface converters are protected against electrostatic discharge of up to kv according to IEC 0-, level. Electromagnetic compatibility and electrical safety All W&T Industry Interfaces meet the limits for noise immunity in industrial environments as well as emissions in commercial and residential areas, so that use of these converters is not subject to any EMC based restrictions. With a maximum permissible supply voltage of V AC/DC (SELV), the described devices do not fall under the Low-Voltage Directive. The power supply must in any case ensure reliable isolation of the low-voltage side from the mains in accordance with EN00. The current Declaration of Conformity for W&T Industry Interfaces can be downloaded in the Internet at the following address:

7 Interface RS <> 0mA, Model 0 RS <> 0mA Converter, model 0 The W&T Interface Converter Model 0 permits bi-directional connection of RS devices with components, which are equipped with an 0mA port. Function The interface converts one data line in each direction and provides electrical isolation between the RS side and the 0mA side. Connectors The two ports of the interface use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out active level signal active level 0mA interface: pin# signal Data Out 0mA Data Out + Data Out - Data Out Half Duplex Control Data In 0mA Data In + Data In - Data In Subject to error and alteration

8 Interface RS <> 0mA, Model 0 Applications A level signal on Pin of the TTY connector will place the 0mA interface of the convertor in half-duplex mode whereby an echo of the sent signals is suppressed. The convertor can be used as an active or passive 0mA component. In the active mode the interface supplies the current required by the respective 0mA loop, while in the passive mode the loop current must be supplied by the connected device. The operating mode can be selected for both loops seperately. Examples of interface switching into active/ passive mode are shown on the following drawings: Interface Tx and Rx loop active RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - passive 0mA device Interface Tx and Rx loop passive RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active 0mA device Interface Tx loop active, interface Rx loop passive RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active / passive 0mA device

9 Interface RS <> 0mA, Model 0 Technical Data Baud rate: Data format: Supported signals: Operating modes: Electrical isolation: Power supply: Current consumption: RS adapter: 0mA adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD active or passive mode both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. DC -pin male SUB-D adapter -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS <> 0mA Converter Subject to error and alteration

10 Interface RS <> 0mA, Model 0

11 Interface RS <> RS/RS, Model 0 & 0 RS <> RS/ converter, Model 0 & 0 The W&T Interface Converters Model 0 and Model 0 permit bi-directional connection of RS devices with components, which are equipped with an RS or RS port. Function The interfaces convert one data line and one handshaking line in each direction and provide electrical isolation between the RS side and the RS/RS side. Overvoltage protection (Model 0 only) The maximum differential voltage allowed to reach the RS transceiver chip of the interfaces from the outside is around ± V according to the data sheets. Voltage exceeding this amount will inevitably result in destruction of the line drivers. Interface model 0 has integrated overvoltage protection which uses suppressor diodes to limit the maximum voltage to approx. ± V. This overvoltage protection is limited of course by the capacity of the protection diodes used, which can let through a current of 0A for a short time. This means it may not be a substitute for a lightning surge arrestor for long cables in exposed locations (e.g. in the mountains). Subject to error and alteration

12 Interface RS <> RS/RS, Model 0 & 0 Connectors The two ports of the interfaces use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out handshake out signal handshake in RS/RS interface: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Operating mode The interfaces can be set for five operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS, RS -wire bus master application One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire / -wire application with echo, handshake control One data channel in each direction is available. The RS output driver is activated with a positive RS handshake in signal, while a negative signal forces the driver to high impedance state. The RS receiving channel is always active in this operating mode. 0

13 Interface RS <> RS/RS, Model 0 & 0 RS, -wire application without echo, handshake control One data channel in each direction is available. The RS output driver is activated with a positive RS handshake in signal, while a negative signal forces the driver to high impedance state. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. RS, wire application / RS -wire application with echo, automatic control One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS, wire application without echo, automatic control One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state Subject to error and alteration

14 Interface RS <> RS/RS, Model 0 & 0 Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS, RS, -wire bus master OFF OFF OFF ON OFF OFF RS, -wire / -wire with echo, handshake control RS, -wire / -wire without echo, handshake control RS, -wire / -wire with echo, automatic control RS, -wire / -wire without echo, automatic control OFF OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF ON OFF ON OFF OFF ON ON OFF ON OFF OFF Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module. +V SW Data In B SW Data In A

15 Interface RS <> RS/RS, Model 0 & 0 Applications RS hardware handshake application RS RS PC TxD RxD CTS DSR DTR DIn DOut HOut HIn 0 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire bus master application RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut 0 DOut A DOut B DIn A DIn B RxD A (-) RxD B (+) TxD A (-) TxD B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) RS device RS device RS -wire application with handshake control RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut HIn 0 DOut A DOut B DIn A DIn B Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device RS -wire application with automatic control RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut 0 DOut A DOut B DIn A DIn B Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device Subject to error and alteration

16 Interface RS <> RS/RS, Model 0 & 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Overvoltage protection: Power supply: Current consumption: RS adapter: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with handshake control RS / wire mode with automatic control approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0..,00 baud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC Model 0 only: limiting of differential voltage by suppressor diodes to Vmax =,V (Imax = 0A, t = 0ms)..V DC/AC approx. DC -pin male SUB-D adapter -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS <> RS/RS Converter

17 Interface 0mA <> RS/RS, Model 0 0mA <> RS/RS Converter, Model 0 The W&T Interface Converter Model 0 permits bi-directional connection of 0mA devices with components, which are equipped with an RS or RS port. Function The interface converts one data line in each direction and provides electrical isolation between the 0mA side and the RS/RS side. Connectors The two ports of the interface use DB male connectors. The connector pin assignments are shown in the table below: RS/RS interface: Pin# Function data out A (-) data in A (-) signal data out B (+) data in B ( +) 0mA interface: pin# signal Data Out 0mA Data Out + Data Out - Data Out Half Duplex Control Data In 0mA Data In + Data In - Data In Subject to error and alteration

18 Interface 0mA <> RS/RS, Model 0 Operating modes 0mA interface A level signal on Pin of the TTY connector will place the 0mA interface of the convertor in half-duplex mode whereby an echo of the sent signals is suppressed. The convertor can be used as an active or passive 0mA component. In the active mode the interface supplies the current required by the respective 0mA loop, while in the passive mode the loop current must be supplied by the connected device. The operating mode can be selected for both loops seperately. Examples of interface switching into active/ passive mode are shown on the applications page. RS/RS interface The interface can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS, RS -wire bus master application One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode.

19 Interface 0mA <> RS/RS, Model 0 RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS, RS, -wire bus master OFF OFF OFF ON OFF OFF RS, -wire bus system OFF ON OFF ON OFF OFF RS, -wire bus system ON ON OFF ON OFF OFF Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Subject to error and alteration

20 Interface 0mA <> RS/RS, Model 0 Applications Interface Tx and Rx loop active RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - passive 0mA device Interface Tx and Rx loop passive RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active 0mA device Interface Tx loop active, interface Rx loop passive RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active / passive 0mA device RS <> 0mA, interface Tx loop active, interface Rx loop passive RS -wire bus 0mA RS device Bus- Bus+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active/passive 0mA device

21 Interface 0mA <> RS/RS, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Power supply: Current consumption: 0mA adapter: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control 0mA: active or passive mode approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0..,00 baud any format RxD, TxD Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. DC -pin male SUB-D adapter -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories 0mA <> RS/RS Converter Subject to error and alteration

22 Interface 0mA <> RS/RS, Model 0 0

23 RS Isolator, Model 0 RS Isolator, Model 0 The W&T RS Isolator Model 0 permits bi-directional connection of two RS devices with an electrical isolation voltage of 000 Volts. Function The isolator supports all data and handshaking lines of pin RS interfaces and has two mutually independent, active RS interfaces. Therefore the isolator can be used as a RS repeater device to double the permissible cable length by inserting the isolator in the middle of the transmission line. Connectors The DTE port of the isolator uses a -pin male SUB-D connector, while the DCE port uses an -pin female SUB-D connector. The connector pin assignments are shown in the table below: RS DCE interface (-pin female) RS DTE interface (-pin male) Pin# Function Direction DCD output RxD output TxD input DTR input DSR output RTS input CTS output RI output Pin# Function Direction DCD input RxD input TxD output DTR output DSR input RTS output CTS input RI input Subject to error and alteration

24 RS Isolator, Model 0 Applications hardware handshake controlled PC <> modem communication DB male DTE DB female DCE DB male DTE DB female DCE PC TxD RxD RTS CTS DSR DCD DTR RI TxD RxD RTS CTS DSR DCD DTR RI 0 TxD RxD RTS CTS DSR DCD DTR RI TxD RxD RTS CTS DSR DCD 0 DTR RI modem software handshake controlled PC <> PC communication DB male DTE DB female DCE DB male DTE DB male DTE PC TxD RxD RTS CTS DSR DCD DTR TxD RxD RTS CTS DSR DCD DTR RI 0 TxD RxD RTS CTS DSR DCD DTR RI RxD TxD CTS RTS DTR DCD DSR PC Technical Data Baud rate: Data format: Supported signals: Electrical isolation: Power supply: Current consumption: RS DTE adapter: RS DCE adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD, RTS, CTS, DSR, DCD, DTR, RI both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. DC -pin male SUB-D adapter -pin female SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS Galvanic Isolator

25 RS/RS Isolator, Model 0 RS / RS Isolator, Model 0 The W&T RS/RS Isolator Model 0 permits bidirectional connection of two RS devices or RS bus systems with an electrical isolation voltage of 000 Volts. Function In RS mode the isolator supports one data and one handshaking line in each direction. In RS mode the isolator supports -wire and -wire bus systems. Connectors The two ports of the device use DB male connectors. The connector pin assignments are shown in the table below: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Subject to error and alteration

26 RS/RS Isolator, Model 0 Operating mode The isolator can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS OFF OFF OFF ON OFF OFF RS, -wire bus system OFF ON OFF ON OFF OFF RS, -wire bus system ON ON OFF ON OFF OFF

27 RS/RS Isolator, Model 0 Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Applications RS hardware handshake application RS device RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire application RS device RS device Bus A (-) Bus B (+) Bus A (-) Bus B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device Subject to error and alteration

28 RS/RS Isolator, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Power supply: Current consumption: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0.. Mbaud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. DC -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS/RS Galvanic Isolator

29 RS/RS Isolator with OVP, Model 0 RS / RS Isolator with OVP, Model 0 The W&T Isolator model 0 enables galvanically isolated connection of RS devices and RS bus systems. In addition, the integrated overvoltage protection ensures troublefree operation even under conditions in which overvoltage on the RS line can be anticipated. Function In RS mode the isolator supports one data and one handshaking line in each direction. In RS mode the isolator supports -wire and -wire bus systems. Overvoltage protection The maximum differential voltage allowed to reach the RS transceiver chip of the interfaces from the outside is around ± V according to the data sheets. Voltage exceeding this amount will inevitably result in destruction of the line drivers. The Isolator model 0 has an integrated overvoltage protection which uses suppressor diodes to limit the maximum voltage to approx. ± V. This overvoltage protection is limited of course by the capacity of the protection diodes used, which can let through a current of 0A for a short time. This means it may not be a substitute for a lightning surge arrestor for long cables in exposed locations (e.g. in the mountains). Subject to error and alteration

30 RS/RS Isolator with OVP, Model 0 Connectors The two ports of the device use DB male connectors. The connector pin assignments are shown in the table below: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Operating mode The isolator can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state.

31 RS/RS Isolator with OVP, Model 0 Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW RS OFF OFF OFF ON OFF RS, -wire bus system OFF ON OFF ON OFF RS, -wire bus system ON ON OFF ON OFF Setting the switching time In both RS modes of the isolator the respective RS transmitter is automatically placed in the active state as soon as data transmission begins, and turned off again with a time delay at the end of the data telegram. Switch S on the DIL switch bank of the interface modules can be used to set the switching time for the respective interface between send and receive mode to values of 0µs (S = on ) and 0µs (S = off ). The required value for the switching time depends on a number of factors, among which are the baud rate, the response time of the accessed RS slaves, and the overall length of the bus system. For this reason it is not feasible to provide an ideal value for all conceivable applications. In practical terms you should use a value for the switching time which lies in the range of a bit time. At.00 kbaud this would correspond to a time of approx. 0µs, and at slower baud rates you should choose the longer of the two times. Other values are possible by means of a factory component change please contact us if this is something you need. Subject to error and alteration

32 RS/RS Isolator with OVP, Model 0 Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Applications RS hardware handshake application RS device RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire application RS device RS device Bus A (-) Bus B (+) Bus A (-) Bus B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device 0

33 RS/RS Isolator with OVP, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Overvoltage protection: Power supply: Current consumption: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control selectable 0µs / 0µs from send to receive for RS automatic control (can be factory changed on request) 0.. Mbaud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC limiting of differential voltage by suppressor diodes to Vmax =,V (Imax = 0A, t = 0ms)..V DC/AC approx. DC -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS/RS Galvanic Isolator Subject to error and alteration

34 RS/RS Isolator with OVP, Model 0

35 RS Line Driver Set, Model 00 RS Line Driver Set, Model 00 The W&T Line Driver Set Model 00 permits bi-directional connection of two RS devices over a distance of up to.00 meters. Function The line driver set consists of two identical interface modules RS <> RS and supports one data and one handshaking line in each direction. To avoid the effects of ground potential difference, both ports of the line driver modules are isolated from each other and from the power supply with a dielectric strength of 000 volts. The line driver modules must be connected to the RS devices by additional shielded serial cables. The pinout of the RS cables is shown in the chapter "Applications" of this manual. Connectors The two ports of the W&T line driver module 00 use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out handshake out signal handshake in RS interface: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Subject to error and alteration

36 RS Line Driver Set, Model 00 Interconnecting cable To ensure proper operation over long distances, -wire or - wire shielded twisted pair (STP) cable should be employed as interconnection cable. Because of the use of balanced RS interfaces, every transmitted RS signal requires one wire pair of the interconnecting cable. RS software handshake communications therefore require pair STP cables, while communications with two additional hardware handshaking lines require pair STP cables. One cable pair must be used for the inverting line (A) and the non-inverting line (B) of the same signal type. The cable shield shall be connected to the shell of the RS interface at both ends of the interconnecting cable. Applications Bidirectional RS application with hardware handshake pin PC COM interface RS RS RS RS pin RS interface PC TxD RxD CTS DSR DTR DIn DOut HOut HIn 00 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B DIn A DIn B DOut A DOut B HIn A HIn B HOut A HOut B 00 DIn DOut HOut HIn TxD RxD CTS DSR 0 DTR Plotter pin PC COM interface Bidirectional RS application with software handshake RS RS RS RS pin PC COM interface PC TxD RxD RTS CTS DSR DTR DIn DOut 00 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B DIn A DIn B DOut A DOut B HIn A HIn B HOut A HOut B 00 DIn DOut TxD RxD RTS CTS DSR DTR PC

37 RS Line Driver Set, Model 00 Technical Data Baud rate: Data format: Supported signals: Max. distance: Electrical isolation: Power supply: Current consumption: RS adapter: RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD, CTS, DTR 000m both ports from each other and from power supply with a dielectric strength of 000 volts DC supplied power adapter or..v DC/AC approx. DC -pin male SUB-D adapter -pin male SUB-D adapter storage: C operation: C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS Line Driver Set Subject to error and alteration

38 RS Line Driver Set, Model 00

W&T Manual Interface modules W&T

W&T Manual Interface modules W&T Manual Subject to error and alteration Model 18801, 18811 18802, 18812 18803, 18813, 18833 18601, 18611 18602, 18612 18613, 18633 18401, 18411 18402, 18412 Release 1.7 43 09/2013 by Wiesemann und Theis

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M USB to Optical Adapter Industrial Isolated RS- 232/422/485 Product Manual Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M 2 USB-COMi-SI-M Product Manual Revision History Revision Date

More information

PCI Express 4-Port Industrial Serial I/O Cards

PCI Express 4-Port Industrial Serial I/O Cards PCI Express 4-Port Industrial Serial I/O Cards The PCIe-400i and PCIe-400i-SI PCI Express 4-port industrial serial I/O cards are plug & play high-speed serial I/O expansion cards for the PCI Express bus.

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Introduction & Specifications of Hi-Speed USB to Serial Adapters Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,

More information

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,

More information

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter Introduction of USB-COMi and USB-COMi-SI The USB-COMi and USB-COMi-SI Industrial Single RS-422/485 Adapters are designed to make

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Media Converters. Media Converters. Product Selection Guides

Media Converters. Media Converters. Product Selection Guides Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3

More information

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware This document lists safety and compliance information for NI Serial legacy hardware, as well as physical specifications, software features, and

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

FX-485PC-IF RS485 Interface Unit Hardware Manual

FX-485PC-IF RS485 Interface Unit Hardware Manual JY992D81801B Date: 2015 April FX- RS485 Interface Unit Hardware Manual This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

USB-COM Plus ISO (USB-COMi SI-M)

USB-COM Plus ISO (USB-COMi SI-M) VS Vision Systems GmbH / Part Number 603 Features 1 x RS232/422/485 port USB 2.0 Full Speed interface 2.5kV isolation per serial port USB and serial ports ESD protected Robust metal case Jumperless, DIP

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer. User Manual IC-485S /IC-485SI Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

Serial to RS422/485 Converter SER 485 PRO( SI) User Manual

Serial to RS422/485 Converter SER 485 PRO( SI) User Manual Serial to RS422/485 Converter SER 485 PRO( SI) User Manual Edition: April 2008 Tel: +49 40 528 401 0 Fax: +49 40 528 401 99 Web: www.visionsystems.de Support: service@visionsystems.de The software described

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485 ME-9000i isolated Serial Interface Board, RS232, RS422, RS485 Protects with isolation Multiport communication English user manual This opto-isolated multiport datacom board offers high safety with standard

More information

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date: EasySync Ltd ES-R-2x01-M RS232 to RS422 / RS485 Converter User Guide Document Reference No.: ES_000011 Issue Date: 2009-04-10 The ES-R-2001-M and ES-R-2101-M provide a simple method of converting RS232

More information

MGate 4101-MB-PBS Series

MGate 4101-MB-PBS Series MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII

More information

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series User s Guide Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The

More information

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j. User manual ADA-4010 RS-485 / RS-422 to RS-232 Converter Copyright 2001-2017 CEL-MAR spj 1 io_ada-4010_v322_en Contents 1 GENERAL INFORMATION 3 11 WARRANTED INFORMATION 3 12 GENERAL CONDITIONS FOR SAFE

More information

Serial Interface Modules TTL to RS232/RS485/RS422

Serial Interface Modules TTL to RS232/RS485/RS422 USERS MANUAL Serial Interface Modules TTL to RS232/RS485/RS422 The modules converts serial TTL signals to RS232 or RS485/RS422. They are available in several different configuration such as directly mountable

More information

Installation & Configuration manual. InduBox GSM IV

Installation & Configuration manual. InduBox GSM IV Installation & Configuration manual InduBox GSM IV 2008 / 02 / 19 2 ! CAUTION! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 02/10/2006

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

SINAUT ST7 Dedicated Line Modem MD2

SINAUT ST7 Dedicated Line Modem MD2 SINAUT ST7 Dedicated Line Modem Operating Instructions Edition 07/2002 SINAUT Telecontrol with SIMATIC S7 Overview 1 Mounting and Installation 2 SINAUT ST7 Dedicated Line Modem Operating Instructions Instructions

More information

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21 SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

Features and Benefits. Certifications

Features and Benefits. Certifications NPort IA5000 Series 1 and 2-port serial device servers for industrial automation Features and Benefits Socket modes: TCP server, TCP client, UDP Patented ADDC (Automatic Data Direction Control) for 2-wire

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company Data Sheet SRM-3A Ultra-Miniature Isolated Short-Range Async Modem The Access Company Features Asynchronous transmission of up to 19.2 kbps Transmission range of up to 13 km (8 miles) Ultra-miniature modem

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

CS485. User s Manual. Version ZYPEX, Inc.

CS485. User s Manual. Version ZYPEX, Inc. CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485) Application Notes (003) Serial Interface (RS232/RS422/RS485) Version 2.0 Sollae Systems Co., Ltd. 1. Overview supports three serial interfaces: RS232, RS422, and RS485. You can select the interface you

More information

Product description Rev. 3 11/06/14

Product description Rev. 3 11/06/14 EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721 Product data sheet 3.1 97.012 EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242 Operation manual 1.0 Introduction...3 1.1 Use of the modem...3 2.0 Operation principles...3 3.0 Installation...3 3.1 RS-232 Interface Connection...4

More information

SER-4485-SI-M USER S MANUAL

SER-4485-SI-M USER S MANUAL SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used

More information

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter USB to Dual RS-422/485 Adapter (USB-2COMi-M) USB to Dual Opto-isolated RS-422/485 Adapter (USB-2COMi-SI-M) - with

More information

MEV Limited USB232/485 INSTRUCTION MANUAL

MEV Limited USB232/485 INSTRUCTION MANUAL MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual

More information

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248 Our Products: USB High Speed - High Isolated - Industry Converter Interfaces Highest quality - on the basis of our experience - we not accept compromise! USB 2.0 - RS485 High Isolated Industry Converter

More information

Manual W&T. Coupling Relays for Web-IO. Release 1.0 Model

Manual W&T. Coupling Relays for Web-IO. Release 1.0 Model Manual Coupling Relays for WebIO Release.0 Model 5705 5706 Relevant Information 04/2009 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

RocketPort Plus Hardware Installation

RocketPort Plus Hardware Installation RocketPort Plus Hardware Installation Introduction This Hardware Installation document discusses the following information: Product overview RocketPort terminology Before installing the hardware Installing

More information

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

Installation Guide of Hi-Speed USB to Industrial I/O Adapter Installation Guide of Hi-Speed USB to Industrial I/O Adapter Introduction of USB-COMi-SI-M The USB Industrial I/O Adapter is designed to make industrial communication port expansion quick and simple. Connecting

More information

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION USER S MANUAL SI-700 SI-700 - EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 TM FOUNDATION S I 7 0 0 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date

More information

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection Product Manual Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M 2 USB-COM-Si-M Product Manual Revision History Revision

More information

Unitronics Devices and RS485 Table Of Contents

Unitronics Devices and RS485 Table Of Contents Unitronics Devices and RS485 Table Of Contents RS485 Options... 1 About RS485... 1 Network Topology & Wiring... 1 RS485 Network Wiring... 1 RS485 wiring considerations... 2 RS485, by controller type...

More information

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Standard-Signal Isolation Amplifiers. VariTrans A 21000 Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20

More information

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M 2 Port USB to RS-422 /485 Optical Isolated Adapter Product Manual Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M 2 USB-2COMi-Si-M Product Manual Revision History Revision Date Author

More information

RTU560 Remote Terminal Unit Connections and Settings

RTU560 Remote Terminal Unit Connections and Settings Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation

More information

Sender Receiver Sender

Sender Receiver Sender EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company Data Sheet SRM-6A Short-Range Asynchronous Modem The Access Company Features Asynchronous, full-duplex modem Data rates of up to 19.2 kbps SRM-6A transmission range of up to 8 km (5.0 mi) (for 24 AWG)

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter Introduction of ES-U-2101-M The USB-to-Optically Isolated RS-422/485 Adapter is designed to make industrial communication port

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

ADAM Fiber Optic to RS-232/422/485 Converter

ADAM Fiber Optic to RS-232/422/485 Converter ADAM-4542+ Fiber Optic to RS-232/422/485 Converter Overview Fiber optic transmission offers the benefits of wide bandwidth, immunity to EMI/RFI interface, and secure data transmission. The ADAM-4542+ can

More information

MAP/950 SERIAL I/O CARD INSTALLATION MANUAL

MAP/950 SERIAL I/O CARD INSTALLATION MANUAL MAP/950 4 PORT ISOLATED RS422/RS485 PCI SERIAL I/O CARD INSTALLATION MANUAL HIGH-PERFORMANCE UART FAMILY This document describes the installation and use of the Axxon Computer Corporation MAP/950 4 Port

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Serial/Ethernet Converter

Serial/Ethernet Converter Serial/Ethernet Converter IE-CS-2TX-1RS232/485 IE-CST-2TX-1RS232/485 IE-CS-2TX-2RS232/485 IE-CST-2TX-2RS232/485 Hardware Installation Guide Second Edition, August 2016 1243440000/01/08.16 Please note:

More information

Integrity Instruments Application Notes. Release 1

Integrity Instruments Application Notes. Release 1 Integrity Instruments Application Notes Release 1 What is EIA/TIA/RS-485 What is EIA/TIA/RS-422 Half Duplex and Full Duplex Communication Asynchronous Communicatin Grounding EIA/TIA/RS-485/422 Shielding

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page

More information

Industrial Media Converters

Industrial Media Converters Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual USB to RS-232/RS422/485 URK-228-I USB To Serial Operation Manual First Edition, Feb 2012 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

RS-232 Industrial Media Converter

RS-232 Industrial Media Converter USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and

More information