LSI MegaRAID Advanced Software Evaluation Guide V3.0

Size: px
Start display at page:

Download "LSI MegaRAID Advanced Software Evaluation Guide V3.0"

Transcription

1 LSI MegaRAID Advanced Software Evaluation Guide V3.0 Contents: n Current sightings to be aware of with Evaluation Kits n MegaRAID Controller Cards that support Advanced Software n Optimum Controller Settings for Advanced Software n Application Qualifier for MegaRAID CacheCade software and MegaRAID FastPath software n LSI Flash Technologies Solution Comparison Chart n Application Parameters That Affect CacheCade Software Performance n SSD Conditioning to optimize real world performance n Using IOMeter to simulate Hot Spot or Hot Data IO activity for Cache- Cade software n Using IOMeter to demonstrate Optimum FastPath software performance n MegaCLI Commands to Enable Fast Path and CacheCade Current sightings to be aware of with Evaluation Kits FastPath Software n Not identifiable from the management tools unless you use MSM v or later. n Must use the latest OS drivers from the LSI website. Drivers embedded with operating systems are not optimized for FastPath software. CacheCade Software n Identified as Super Sized Cache Disk (SSCD) in MSM unless you are using version 6.96 or later. n System re-boot is required after increasing the number of SSDs in a CacheCade volume. n Must use the latest OS drivers from the LSI website. Drivers embedded with operating systems are not optimized for CacheCade software. n Make sure FastPath software is also enabled with the current CacheCade software release in order to maximize performance. A change is being made to make this step unnecessary in a future release. MegaRAID Controllers Supported n i4e n i n i n e (electronic fulfillment only) Standard volume policy for CacheCade Software Write Policy: Should be determined based on your write workload characteristics and data safety requirements. Often enabling MegaRAID write-back caching improves performance, especially when drive write caching is disabled. IO Policy: Cached IO Read Policy: No Read Ahead Stripe Size: 64KB

2 Notes: 1. Cached IO enables CacheCade feature. Use DIO if you do not want a VD s data cached by CacheCade. 2. Parameters above provide the best performance over the broadest range of configurations and workloads. Standard volume policy for FastPath Software Write Policy: Write Through IO Policy: Direct IO Read Policy: No Read Ahead Stripe Size: 64KB Note: 1. Write Through and Direct IO enables FastPath feature for solid-state drives (SSDs). If either Write Back or Cached IO are used, then full FastPath performance can not be achieved. 2. Parameters above provide the best performance over the broadest range of configurations and workloads. Have found in some instances that smaller and or larger strip size can provide some additional performance benefit. Application Qualifier for CacheCade and FastPath Software Application Profiles That Benefit from SSDs Web Servers and other transactional, small random read intensive applications File server (including SharePoint) server Databases OLTP E-Commerce Large sequential databases Streaming read applications Streaming write applications Recommended Advanced Software CacheCade Software CacheCade or FastPath Software CacheCade or FastPath Software CacheCade or FastPath Software CacheCade or FastPath Software CacheCade or FastPath Software FastPath Software FastPath Software FastPath Software LSI Flash Technologies Solution Comparison Chart S O L U T I O N S S D C a p a c i t y N e e d e d E x i s t i n g H D D R A I D D a t a V o l u m e ( s ) A c c e l e r a t e d T a r g e t e d A p p l i c a t i o n W o r k l o a d P e r f o r - m a n c e G a i n C o s t o f C a p a c i t y C o s t o f O w n e r - s h i p ( 4 ) Install 64GB of DDR3 Server Memory None No Change Required All Volumes File System Cached All workload, Especially Random Highest $$$$ $ Add More Short Stroked HDDs None Redistribute on HDDs One HDD Volume All Workloads Low (2) $ (3) $$$$ CacheCade Hot Data Only (1) No Change Required One or More HDD Volumes Random Read Intensive Moderate $$ $$ FastPath All Volume Data Load or Migrate to SSD One SSD Volume All Workloads, Especially Random High $$$ $ 1. CacheCade max. SSD capacity 512GB 2. Depends on the class and number of HDDs added and amount of short stroking 3. Depends on the amount of usable HDD storage when short stroking 4. Power, space, cooling, reliability, etc. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 2

3 Application Parameters That Affect CacheCade Software Performance Size of the working data set The working data set is a subset of the total stored data actively utilized by an application or applications at a specific point in time. The size of working data set varies from a small portion of the total amount of data stored up to all of the stored data depending on the application and typical usage model. Note: Frequently accessed data or hot data are other terms often used to refer to the working data set. Size of the SSD cache 1. Performance will scale as more active read data fits in the SSD cache. Tools such as Microsoft XPERF can be used to determine the working data set size so the optimal SSD cache capacity can be determined. Alternatively, adding SSD cache capacity until maximum performance is obtained and when adding additional SSD cache capacity does not significantly improve performance. Access patterns (READs vs. WRITEs) 1. Today, CacheCade software is optimized for the READ intensive applications where the majority of working data set fits in SSD cache. Write performance is largely determined by the underlining HDD volume. Because SSD cache off loads the majority of read accesses to the working data set the read and write performance of the underlining HDD volume is also enhanced. Percentage of READs vs. WRITEs 1. Applications with a very large random or sequential access ranges show less improvement with CacheCade software. This is because there are no frequently accessed data hot spots under these conditions. For these situations FastPath software provides the best performance enhancement alternative. 2. For large wording data sets or sequential write intensive workloads, FastPath provides the best performance enhancement alternative. The figure below illustrates READ and WRITE access patterns of a medium sized (93 GB) transactional database, which is an ideal candidate for CacheCade software. 1.1 E GB Range db + logs Disks Access Range (bytes) 9E E E E E + 10 MySQL database IO activity Seconds { 2.5 GB Range Special database Access Component Read Write Logging LSI MegaRAID Advanced Software Evaluation Kit Release Notes 3

4 SSD conditioning to optimize real world performance IOMeter pre-conditioning: Within IOMeter, perform 128KB sequential writes and then perform 4KB random writes for each SSD. Make sure I/Os are aligned on 4KB sectors. Typically each workload should be run from 30-minutes to one hour depending on the SSD capacity. You can estimate the total run time by monitoring the IOMeter data throughput rate while running 128KB sequential writes. For example take a 50GB SSD and measure 128KB sequential write throughput of 50MB/s the estimated minimum run time for each IOMeter workload is (50 GB * 1024 MB/GB)/(50 MB/s) = 1024 seconds or 17 minutes. If each SSD is not preconditioned in some fasion then SSD performance will initially be abnormally high and then slow decrease over time to stable pre-conditioned SSD performance specifications. Real-world application benchmark performance stabilization: When running real-world application benchmarks, make at least two long runs, typically 1-hour each, to make sure a steady state of performance is reached. If the performance of the second run is > 10% greater than or less than first run then continue to run until performance stabilizes. Some examples of real world benchmark applications include: n MySQL with SysBench n Microsoft Exchange with JetStress n Microsoft SQL with TPC-E n Microsoft IIS web server with NeoLoad Using IOMeter to simulate Hot Spot Data IO activity for CacheCade Software IOMeter generates purely random IOs. So if you do not create a real world workload with a working data set consistent with the available SSD cache capacity, the purely random nature of IOMeter will not be able to leverage read caching on the SSDs. The procedure below will allow you to simulate hot spot activity. Small Synthetic Working Data Set IOMeter Benchmark n Create a VD that uses the entire HDD array. n Load CacheCade with the following cache priming procedure SSD Cache Priming for Small Synthetic Working Data Set IOMeter Benchmark We recommend using two IOmeter workers. In this example we set the maximum disk sector size to 62,914,560, which equals a 30 GB data hot spot: (30 GB) * (1024^3 Bytes per GB)]/(512 bytes per sector). Set up both workers the same for a total command queue depth of 128. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 4

5 For the access specification transfer size, select 32KB, 100% sequential reads aligned on 32KB boundaries. Next, Create SAS or SATA HDD volume configured to Write Back/Cached IO/No Read Ahead/Drive Write Cache Enabled/Stripe Size 64KB. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 5

6 Now perform 4KB Random Reads (QD=64) across the 30GB region with two workers. Align the I/Os on 4Kb sectors. IOmeter should measure roughly 39,000 IOps for single Intel X25-E SSD. Steady state performance will not be reached until the SSD cache is fully loaded. 140,000 IOps is the absolute maximum MegaRAID controller 4KB random read performance for CacehCade. Typically, with more capacity added to the Cache- Cade pool, you should be able to measure approximately 60,000 to 100,000 IOps. Other Tips: n Pre-load CacheCade software and run IOMeter before demoing with customers. n Configuration option for a larger number of SSDs in the CacheCade solution: LSI 620J enclosure with 16 each 2.5 SAS HDDs with room for up to 8 each 2.5 SSDs, allowing connection via two x4 SAS cables. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 6

7 Full Disk Access IOMeter Benchmark for CacheCade Software This benchmark exercise simulates a stressful real world workload emulating one or more applications accessing a large data set at different rates, creating graduated regions of access frequency. It provides an excellent test of CacheCade read caching technology and demonstrates the effectiveness of hot read data detection and retention. n Use multiple workers accessing overlapping HDD VD sector ranges n Emulates different users and/or applications accessing different but overlapped HDD VD ranges simultaneously n Emulates a small hot data range with progressively larger warm, cool and cold data access ranges. n More frequent accesses to smaller hot data range and progressively less frequent accesses to warm, medium and cold ranges. n Steady state performance will not be reached until CacheCade cache is fully loaded. Figure one below illustrates a series of workers, or threads, that are accessing various regions of VD that encompasses the entire disk group. These overlapping access regions represent different degrees of disk activity ranging from hot (thread 4) to cold (thread 1). The cold data range is set to 100% of the HDD VD capacity (thread 1) down to 12.5% for hot data range (thread 4). The queue depths (QD) represent disk IO activity (QD=1 is the lowest and QD=32 is the highest). The hot data range should be set to less than the SSD cache capacity. n Thread 1 = 100%, QD=1 n Thread 2 = 50%, QD=2 n Thread 3 = 25%, QD=4 n Thread 4 = 12.5%, QD=32 Make sure SSD capacity is greater than hot data or greater then hot and warm data if you choose to cache both. I/O is run for 5 minutes to prime the cache, then performance is captured for 1 minute. Figure 1: Full disk access illustration. Cold Zone (Ave QD.500) Thread 1 Cool Zone (Ave QD 1.25) }} } } Hot Zone (Ave QD ) Warm Zone (Ave QD 2.625) Thread 4 Thread 3 Thread 2 LSI MegaRAID Advanced Software Evaluation Kit Release Notes 7

8 Full Disk Access IOMeter Setup The system configuration used for this example is based on a RAID-0 volume consisting of twelve (12) 137GB 6Gb/s SAS HDDs. Four (4) Intel X25-E SATA Solid State Drives with approximately 29.8GB of usable capacity for total of 119GB. The SSDs had been previously used for several months of strenuous testing, thus they were very worn in, which is ideal for this exercise. Twelve drive RAID 0 VD Four Intel X25- E SSDs The Table below illustrates the queue depths and disk sector ranges that were used for each IOMeter worker or thread. As you can see, the Hot read data region sized to fit within the available CacheCade SSD cache capacity indicated above. R E G I O N Q U E U E D E P T H S T A R T D I S K S E C T O R M A X D I S K S E C T O R S I Z E R A N G E C A P A C I T Y ( G B ) Cold GB Cool GB Warm GB Hot GB LSI MegaRAID Advanced Software Evaluation Kit Release Notes 8

9 From the Disk Targets tab, select the appropriate raw storage device. Enter the Maximum Disk Size for each worker, which represents the Cold, Cool, Warm and Hot regions Next, select the Access Specifications tab to define the IO profile to be tested. Run IOMeter 4K 100% random read access profile to obtain maximum IOPs performance. You can ether edit one of the pre-defined IO profiles, or select the New button. When editing the access specification, make sure that IOs are aligned to the transfer request size. In this example the transfer size 4KB and the IOs are aligned to 4KB as well. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 9

10 Next select the Test Setup tab. Make sure you select a run time that is long enough to allow CacheCade to fully populate the SSDs with hot data. The first few minutes of the test will indicate the read performance of the HDD array as data is being read and re-read for the first time. Once the CacheCade technology identifies data as hot and copies it in to the SSD cache pool, IOPs performance will dramatically scale, as indicated in the chart below. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 10

11 Using IOMeter to Demonstrate Optimum FastPath Software Performance Note: SSD pre-conditioning procedure as described above should be performaned on a FastPath SSD VD especially before demonstrating random write performance. Optimum Controller settings for FastPath Write Policy: Write Through IO Policy: Direct IO Read Policy: No Read Ahead Stripe Size: 64KB 4 SSDs in a RAID 0 volume. Run IOMeter 4K 100% random read access profile to obtain maximum IOPs performance. We also recommend running 4KB random write performance. While 4KB random write performance is much lower than 4KB random reads, it is still significantly better than HDD performance. Note that CacheCade and FastPath performance depends on SSD performance. SSD performance depends on make, model, firmware, technology, specifications, and number of SSDs used. It is important to select the right SSD to achieve customer s performance requirements. The chart below displays IOMeter benchmark results on an MLC and an SLC SSD. The single drives were configured as RAID 0 arrays. 4KB random writes were performed on the SSDs over two hours. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 11

12 MLC SLC KB RW Queue Dept 128 4KB RW Queue Dept 256 MegaCLI Commands to Enable Fast Path and CacheCade Software (Commands below assume CacheCade and Fast Path feature keys already installed.) MegaCli -LDSetProp {-Name LdNamestring} -RW RO Blocked WT WB [-Immediate] RA NORA ADRA Cached Direct -EnDskCache DisDskCache CachedBadBBU NoCachedBadBBU -Lx -L0,1,2 -Lall -an -a0,1,2 -aall Use the following commands on the LD number you want to modify. So if you had only one LD, that being LD0, the command would be: FastPath software: megacli LDSetProp WT Direct NORA L0 a0 Or you can issue these one at a time such as: Megacli LDSetProp WT L0 a0 Megacli LDSetProp Direct L0 a0 Megacli LDSetProp NORA L0 a0 CacheCade software: Megacli LDSetProp WB NORA Cached CachedBadBBU L0 a0 Or you can issue these one at a time such as: Megacli LDSetProp WB L0 a0 Megacli LDSetProp NORA L0 a0 Megacli LDSetProp Cached L0 a0 Megacli CachedBadBBU Cached L0 a0 (Cached Bad BBU command will make sure the controller stays in Write Back mode with no battery connected.) The stripe size is set at creation time, and cannot be changed with LDSetProp. LSI MegaRAID Advanced Software Evaluation Kit Release Notes 12

13 * A 14GB volume on a two drive RAID 1 array was used to simulate web server re-read hot spot activity. Using IOMeter version , a MegaRAID SAS e with configuration settings: No Read Ahead, Write Back Cache, 64KB Stripe Size and Direct IO, using firmware version , reached 14,896 IOs per second with CacheCade enabled, compared to 273 IOs per second with CacheCade disabled. This represents an increase of more than 50x. For more information and sales office locations, please visit the LSI web sites at: lsi.com lsi.com/channel LSI, LSI and Design logo, CacheCade, FastPath, MegaRAID, MegaRAID Storage Manager, SafeStore, and SSD Guard are trademarks or registered trademarks of LSI Corporation. All other brand and product names may be trademarks of their respective companies. LSI Corporation reserves the right to make changes to any products and services herein at any time without notice. LSI does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI; nor does the purchase, lease, or use of a product or service from LSI convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI or of third parties. Copyright 2010 by LSI Corporation. All rights reserved. Feb 2011

LSI and HGST accelerate database applications with Enterprise RAID and Solid State Drives

LSI and HGST accelerate database applications with Enterprise RAID and Solid State Drives LSI and HGST accelerate database applications with Enterprise RAID and Solid State Drives HGST Ultrastar enterprise-class solid state drives (SSDs) connected to LSI MegaRAID 6Gb/s SAS+SATA RAID controller

More information

Intel RAID Web Console 2 and StorCLI Command Line Tool

Intel RAID Web Console 2 and StorCLI Command Line Tool SOLUTIONS Brief Intel RAID Web Console 2 and StorCLI Command Line Tool Powered by LSI* MegaRAID technology Instant access, intuitive configuration/navigation, easy standard storage management and advanced

More information

Benchmarking Enterprise SSDs

Benchmarking Enterprise SSDs Whitepaper March 2013 Benchmarking Enterprise SSDs When properly structured, benchmark tests enable IT professionals to compare solid-state drives (SSDs) under test with conventional hard disk drives (HDDs)

More information

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide The ServeRAID M5000 Series Performance Accelerator Key for System x enables performance enhancements needed by emerging SSD

More information

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Front cover Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Introduces the SSD Performance Accelerator for Lenovo servers Describes the performance gains from using MegaRAID

More information

Accelerate Database Performance and Reduce Response Times in MongoDB Humongous Environments with the LSI Nytro MegaRAID Flash Accelerator Card

Accelerate Database Performance and Reduce Response Times in MongoDB Humongous Environments with the LSI Nytro MegaRAID Flash Accelerator Card Accelerate Database Performance and Reduce Response Times in MongoDB Humongous Environments with the LSI Nytro MegaRAID Flash Accelerator Card The Rise of MongoDB Summary One of today s growing database

More information

IBM and HP 6-Gbps SAS RAID Controller Performance

IBM and HP 6-Gbps SAS RAID Controller Performance IBM and HP 6-Gbps SAS RAID Controller Performance Evaluation report prepared under contract with IBM Corporation Introduction With increasing demands on storage in popular application servers, the server

More information

Storage Adapter Testing Report

Storage Adapter Testing Report -Partnership that moves your business forward -Making imprint on technology since 1986 LSI MegaRAID 6Gb/s SATA+SAS Storage Adapter Testing Report Date: 12/21/09 (An Authorized Distributor of LSI, and 3Ware)

More information

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2014

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2014 P RO D UC T SEL EC TOR GUID E Storage Adapters March 2014 LSI Storage Adapters Nytro Flash Acceleration Solutions...Page 3 MegaRAID Solutions....Page 5 3ware Solutions....Page 6 Syncro Shared Solutions...Page

More information

Product and Version: RAID SAS LSI Controller: 1068 based: 8300XLP, 8408E, 8480E, ROMB of R based: 8704ELP, 8708EM2, ROMB of R480 E1

Product and Version: RAID SAS LSI Controller: 1068 based: 8300XLP, 8408E, 8480E, ROMB of R based: 8704ELP, 8708EM2, ROMB of R480 E1 Technical Information Document COE Servers Document Title: LSI SAS Card and BBU error / BBU calibration Troubleshoot BBU issues Document ID: TID0612071320 Creation Date: 07 Dec. 2006 Modified Date: 15

More information

Using Synology SSD Technology to Enhance System Performance Synology Inc.

Using Synology SSD Technology to Enhance System Performance Synology Inc. Using Synology SSD Technology to Enhance System Performance Synology Inc. Synology_WP_ 20121112 Table of Contents Chapter 1: Enterprise Challenges and SSD Cache as Solution Enterprise Challenges... 3 SSD

More information

2013 LENOVO. ALL RIGHTS RESERVED.

2013 LENOVO. ALL RIGHTS RESERVED. RAID Product Directions LSI is strategic partner for complete RAID solutions Industry leader in RAID technology Best in class storage subsystem performance LSI RAID technology / products supported across

More information

MegaRAID SAS e RAID Controller

MegaRAID SAS e RAID Controller MegaRAID SAS 9286-8e RAID Controller Quick Installation Guide 53823-00, Rev. A 53823-00A Revision History Version and Date 53823-00, Rev. A, Initial release of the document. Description of Changes LSI

More information

G i v e Y o u r H a r d D r i v e w h a t i t s B e e n M i s s i n g P e r f o r m a n c e The new Synapse

G i v e Y o u r H a r d D r i v e w h a t i t s B e e n M i s s i n g P e r f o r m a n c e The new Synapse OCZ Synapse Cache Solid State Drives accelerate workstation and desktop computing applications with an innovative hardware-meets-software design and advanced caching feature-set. Delivers up to 8, IOPS

More information

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2012

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2012 P RO D UC T SEL EC TOR GUID E Storage Adapters March 2012 MegaRAID Solutions MegaRAID Ordering Part No. PKG Host Bus Type Channel/ Ports I/O Processor External Internal Cache Protection Option Memory (MB)

More information

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation report prepared under contract with Dot Hill August 2015 Executive Summary Solid state

More information

PowerVault MD3 SSD Cache Overview

PowerVault MD3 SSD Cache Overview PowerVault MD3 SSD Cache Overview A Dell Technical White Paper Dell Storage Engineering October 2015 A Dell Technical White Paper TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS

More information

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide MegaRAID SAS 9285CV-8e RAID Controller Quick Installation Guide LSI, the LSI & Design logo, MegaRAID, CacheVault, CacheCade, and SafeStore are trademarks or registered trademarks of LSI Corporation or

More information

Entry-level Intel RAID RS3 Controller Family

Entry-level Intel RAID RS3 Controller Family PRODUCT Brief Entry-Level Intel RAID RS3 Controller Portfolio Entry-level Intel RAID RS3 Controller Family 12Gb/s connectivity and basic data protection RAID matters. Rely on Intel RAID. Cost-effective

More information

HP SAS benchmark performance tests

HP SAS benchmark performance tests HP SAS benchmark performance tests technology brief Abstract... 2 Introduction... 2 Test hardware... 2 HP ProLiant DL585 server... 2 HP ProLiant DL380 G4 and G4 SAS servers... 3 HP Smart Array P600 SAS

More information

LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE

LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE Luanne Dauber, Pure Storage Author: Matt Kixmoeller, Pure Storage SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless

More information

Recommendations for Aligning VMFS Partitions

Recommendations for Aligning VMFS Partitions VMWARE PERFORMANCE STUDY VMware ESX Server 3.0 Recommendations for Aligning VMFS Partitions Partition alignment is a known issue in physical file systems, and its remedy is well-documented. The goal of

More information

LSI SAS6160 LSI SAS Switch. Configuration Guide

LSI SAS6160 LSI SAS Switch. Configuration Guide LSI SAS6160 LSI SAS Switch Configuration Guide 2010 SAS Switch The LSI SAS6160 Switch is a ½ wide, 16-port switch that fits into the 1U form factor. The switch extends the capabilities of SAS in direct-attached

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters

More information

JetStor White Paper SSD Caching

JetStor White Paper SSD Caching JetStor White Paper SSD Caching JetStor 724iF(D), 724HS(D) 10G, 712iS(D), 712iS(D) 10G, 716iS(D), 716iS(D) 10G, 760iS(D), 760iS(D) 10G Version 1.1 January 2015 2 Copyright@2004 2015, Advanced Computer

More information

Managing Storage Adapters

Managing Storage Adapters This chapter includes the following sections: Self Encrypting Drives (Full Disk Encryption), page 2 Create Virtual Drive from Unused Physical Drives, page 3 Create Virtual Drive from an Existing Drive

More information

Solid State Drive (SSD) Cache:

Solid State Drive (SSD) Cache: Solid State Drive (SSD) Cache: Enhancing Storage System Performance Application Notes Version: 1.2 Abstract: This application note introduces Storageflex HA3969 s Solid State Drive (SSD) Cache technology

More information

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Evaluation report prepared under contract with LSI Corporation Introduction IT professionals see Solid State Disk (SSD) products as

More information

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays TECHNICAL REPORT: Performance Study Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays ABSTRACT The Dell EqualLogic hybrid arrays PS6010XVS and PS6000XVS

More information

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis This white paper highlights the impressive storage performance of the PowerEdge FD332 storage node in the FX2

More information

SSD Applications in the Enterprise Area

SSD Applications in the Enterprise Area SSD Applications in the Enterprise Area Tony Kim Samsung Semiconductor January 8, 2010 Outline Part I: SSD Market Outlook Application Trends Part II: Challenge of Enterprise MLC SSD Understanding SSD Lifetime

More information

FAQs HP Z Turbo Drive Quad Pro

FAQs HP Z Turbo Drive Quad Pro FAQs HP Z Turbo Drive Quad Pro Product performance/implementation What is the HP Z Turbo Drive PCIe SSD? The HP Z Turbo Drive PCIe SSD is the family name for an M.2 PCIe connected SSD. The M.2 PCIe card

More information

Performance Consistency

Performance Consistency White Paper Performance Consistency SanDIsk Corporation Corporate Headquarters 951 SanDisk Drive, Milpitas, CA 95035, U.S.A. Phone +1.408.801.1000 Fax +1.408.801.8657 www.sandisk.com Performance Consistency

More information

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Overview IBM Easy Tier is a performance function that automatically and non-disruptively migrates frequently accessed

More information

Introducing and Validating SNIA SSS Performance Test Suite Esther Spanjer SMART Modular

Introducing and Validating SNIA SSS Performance Test Suite Esther Spanjer SMART Modular Introducing and Validating SNIA SSS Performance Test Suite Esther Spanjer SMART Modular Abstract SSS Performance Benchmarking Learning Objectives Get a good understanding of the various parameters that

More information

Cisco UCS C-Series I/O Characterization

Cisco UCS C-Series I/O Characterization White Paper Cisco UCS C-Series I/O Characterization White Paper May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 38 Contents Executive Summary...

More information

AN ALTERNATIVE TO ALL- FLASH ARRAYS: PREDICTIVE STORAGE CACHING

AN ALTERNATIVE TO ALL- FLASH ARRAYS: PREDICTIVE STORAGE CACHING AN ALTERNATIVE TO ALL- FLASH ARRAYS: PREDICTIVE STORAGE CACHING THE EASIEST WAY TO INCREASE PERFORMANCE AND LOWER STORAGE COSTS Bruce Kornfeld, Chief Marketing Officer, StorMagic Luke Pruen, Technical

More information

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510 A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510 Incentives for migrating to Exchange 2010 on Dell PowerEdge R720xd Global Solutions Engineering

More information

Lenovo RAID Introduction Reference Information

Lenovo RAID Introduction Reference Information Lenovo RAID Introduction Reference Information Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and cost-efficient methods to increase server's storage performance,

More information

MegaRAID CacheVault Power Module 02

MegaRAID CacheVault Power Module 02 MegaRAID CacheVault Power Module 02 Quick Installation Guide 53377-00, Rev. B Revision History Version and Date Description of Changes 53377-00, Rev. B, Revised the copyright information and Figure 3.

More information

Syncro CS e Controller

Syncro CS e Controller Syncro CS 9286-8e Controller Quick Installation Guide 54127-00, Rev. B 54127-00B Syncro CS 9286-8e RAID Controller Quick Installation Guide Revision History Version and Date Description of Changes 54127-00,

More information

MegaRAID CacheVault Flash Module 02

MegaRAID CacheVault Flash Module 02 MegaRAID CacheVault Flash Module 02 Quick Installation Guide 53378-00, Rev. B MegaRAID CacheVault Flash Module CVFM02 Quick Installation Guide Revision History Version and Date Description of Changes 53378-00,

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for IBM System x are the next-generation 6 Gbps SAS

More information

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage TechTarget Dennis Martin 1 Agenda About Demartek Enterprise Data Center Environments Storage Performance Metrics

More information

megacli-python Documentation

megacli-python Documentation megacli-python Documentation Release 0.0.10 Matteo Cerutti Jun 27, 2018 Contents: 1 Indices and tables 5 Python Module Index 7 i ii megacli-python Documentation, Release 0.0.10 Python library for MegaCli

More information

SELECTION GUIDE. Storage Solutions. broadcom.com

SELECTION GUIDE. Storage Solutions. broadcom.com SELECTION GUIDE Storage Solutions broadcom.com The amount and variety of data produced by contentrich Internet, cloud and enterprise applications poses unprecedented challenges for data centers of all

More information

Samsung Z-SSD SZ985. Ultra-low Latency SSD for Enterprise and Data Centers. Brochure

Samsung Z-SSD SZ985. Ultra-low Latency SSD for Enterprise and Data Centers. Brochure Samsung Z-SSD SZ985 Ultra-low Latency SSD for Enterprise and Data Centers Brochure 1 A high-speed storage device from the SSD technology leader Samsung Z-SSD SZ985 offers more capacity than PRAM-based

More information

Storage Solutions. Product Guide. Spring 2011

Storage Solutions. Product Guide. Spring 2011 Storage Solutions Product Guide Spring 2011 LSI Storage Solutions Table of Contents Introduction to LSI...Page 3 MegaRAID SATA+SAS...Page 4 MegaRAID SATA+SAS Feature Product Line...Page 5 MegaRAID SATA+SAS

More information

SUPERTALENT ULTRADRIVE LE/ME PERFORMANCE IN APPLE MAC WHITEPAPER

SUPERTALENT ULTRADRIVE LE/ME PERFORMANCE IN APPLE MAC WHITEPAPER SUPERTALENT ULTRADRIVE LE/ME PERFORMANCE IN APPLE MAC WHITEPAPER 2.5 SATA-II SOLID STATE DRIVE Copyright Information: Copyright, Super Talent Technology. All rights reserved. All trademarks property of

More information

Intel Solid State Drive 660p Series

Intel Solid State Drive 660p Series Evaluation Guide December 2018 Order Number: 337971-004US Ordering Information Contact your local Intel sales representative for ordering information. Revision History Revision Number Description Revision

More information

Adaptec Series 7 SAS/SATA RAID Adapters

Adaptec Series 7 SAS/SATA RAID Adapters Adaptec Series 7 SAS/SATA RAID Adapters PCIe Gen3 family of high port count 6Gb/s solutions with game-changing performance Introduction Business and consumer demand for fast and reliable access to data

More information

Performance Modeling and Analysis of Flash based Storage Devices

Performance Modeling and Analysis of Flash based Storage Devices Performance Modeling and Analysis of Flash based Storage Devices H. Howie Huang, Shan Li George Washington University Alex Szalay, Andreas Terzis Johns Hopkins University MSST 11 May 26, 2011 NAND Flash

More information

Non-Volatile Memory Cache Enhancements: Turbo-Charging Client Platform Performance

Non-Volatile Memory Cache Enhancements: Turbo-Charging Client Platform Performance Non-Volatile Memory Cache Enhancements: Turbo-Charging Client Platform Performance By Robert E Larsen NVM Cache Product Line Manager Intel Corporation August 2008 1 Legal Disclaimer INFORMATION IN THIS

More information

The Benefits of Solid State in Enterprise Storage Systems. David Dale, NetApp

The Benefits of Solid State in Enterprise Storage Systems. David Dale, NetApp The Benefits of Solid State in Enterprise Storage Systems David Dale, NetApp SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4 W H I T E P A P E R Comparison of Storage Protocol Performance in VMware vsphere 4 Table of Contents Introduction................................................................... 3 Executive Summary............................................................

More information

SSDs Driving Greater Efficiency in Data Centers

SSDs Driving Greater Efficiency in Data Centers SSDs Driving Greater Efficiency in Data Centers - Tutorial - June 23 rd, 2010 Tony Kim Samsung Semiconductor Inc. Table of Contents Part I: IT Industry Trend & SSD Market Outlook SSD Introduction & Application

More information

Samsung SSD PM863 and SM863 for Data Centers. Groundbreaking SSDs that raise the bar on satisfying big data demands

Samsung SSD PM863 and SM863 for Data Centers. Groundbreaking SSDs that raise the bar on satisfying big data demands Samsung SSD PM863 and SM863 for Data Centers Groundbreaking SSDs that raise the bar on satisfying big data demands 2 Samsung SSD PM863 and SM863 Innovations in solid state As the importance of data in

More information

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions A comparative analysis with PowerEdge R510 and PERC H700 Global Solutions Engineering Dell Product

More information

Easily Recreate the Qtier SSD Tier

Easily Recreate the Qtier SSD Tier Easily Recreate the Qtier SSD Tier 1 2 3 4 SSDs Need To Be Upgraded Re-create Qtier SSD Tier Demo Remove Qtier SSD Tier More Scenarios and Recap SSDs Need To Be Upgraded SSD Evolution Trend Change Qtier

More information

Virtual Storage Tier and Beyond

Virtual Storage Tier and Beyond Virtual Storage Tier and Beyond Manish Agarwal Sr. Product Manager, NetApp Santa Clara, CA 1 Agenda Trends Other Storage Trends and Flash 5 Min Rule Issues for Flash Dedupe and Flash Caching Architectural

More information

What is QES 2.1? Agenda. Supported Model. Live demo

What is QES 2.1? Agenda. Supported Model. Live demo What is QES 2.1? Agenda Supported Model Live demo QES-Based Unified Storage Windows Server Block File iscsi CIFS NFS QES 2.1 One Architecture & Three Configurations SSD SSD Spinning Disk Hybrid All Flash

More information

Samsung PM1725a NVMe SSD

Samsung PM1725a NVMe SSD Samsung PM1725a NVMe SSD Exceptionally fast speeds and ultra-low latency for enterprise application Brochure 1 Extreme performance from an SSD technology leader Maximize data transfer with the high-performance,

More information

Assessing performance in HP LeftHand SANs

Assessing performance in HP LeftHand SANs Assessing performance in HP LeftHand SANs HP LeftHand Starter, Virtualization, and Multi-Site SANs deliver reliable, scalable, and predictable performance White paper Introduction... 2 The advantages of

More information

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide ServeRAID F5115-200GB and 800GB SAS/SATA Controllers for IBM System x Product Guide The ServeRAID F Series family of products offers MegaRAID data protection and flexible onboard flash technology that

More information

Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3.0 SSD Read and Write Caching Solutions

Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3.0 SSD Read and Write Caching Solutions Reduce Latency and Increase Application Performance Up to 44x with Adaptec maxcache 3. SSD Read and Write Caching Solutions Executive Summary Today s data centers and cloud computing environments require

More information

Dell EMC PowerEdge R740xd as a Dedicated Milestone Server, Using Nvidia GPU Hardware Acceleration

Dell EMC PowerEdge R740xd as a Dedicated Milestone Server, Using Nvidia GPU Hardware Acceleration Dell EMC PowerEdge R740xd as a Dedicated Milestone Server, Using Nvidia GPU Hardware Acceleration Dell IP Video Platform Design and Calibration Lab June 2018 H17250 Reference Architecture Abstract This

More information

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide The ServeRAID M5120 SAS/SATA Controller for IBM System x is a part of the ServeRAID M Series family, which offers a complete server storage

More information

Performance Testing December 16, 2017

Performance Testing December 16, 2017 December 16, 2017 1 1. vsan Performance Testing 1.1.Performance Testing Overview Table of Contents 2 1. vsan Performance Testing Performance Testing 3 1.1 Performance Testing Overview Performance Testing

More information

Demartek Evaluation Accelerated Business Results with Seagate Enterprise Performance HDDs

Demartek Evaluation Accelerated Business Results with Seagate Enterprise Performance HDDs May 2017 Demartek Evaluation Accelerated Business Results with Seagate Enterprise Performance HDDs Executive Summary In today s world of digital transformation, organizations require high performance compute

More information

Samsung V-NAND SSD 970 EVO Plus

Samsung V-NAND SSD 970 EVO Plus Samsung V-NAND SSD 970 EVO Plus 2019 1 DISCLAIMER SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed herein

More information

Evaluation Report: Supporting Multiple Workloads with the Lenovo S3200 Storage Array

Evaluation Report: Supporting Multiple Workloads with the Lenovo S3200 Storage Array Evaluation Report: Supporting Multiple Workloads with the Lenovo S3200 Storage Array Evaluation report prepared under contract with Lenovo Executive Summary Virtualization is a key strategy to reduce the

More information

Cisco UCS C240 M4 I/O Characterization

Cisco UCS C240 M4 I/O Characterization White Paper Cisco UCS C240 M4 I/O Characterization Executive Summary This document outlines the I/O performance characteristics of the Cisco UCS C240 M4 Rack Server using the Cisco 12-Gbps SAS modular

More information

NVMFS: A New File System Designed Specifically to Take Advantage of Nonvolatile Memory

NVMFS: A New File System Designed Specifically to Take Advantage of Nonvolatile Memory NVMFS: A New File System Designed Specifically to Take Advantage of Nonvolatile Memory Dhananjoy Das, Sr. Systems Architect SanDisk Corp. 1 Agenda: Applications are KING! Storage landscape (Flash / NVM)

More information

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c

Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c White Paper Deploy a High-Performance Database Solution: Cisco UCS B420 M4 Blade Server with Fusion iomemory PX600 Using Oracle Database 12c What You Will Learn This document demonstrates the benefits

More information

ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide

ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide The ServeRAID M5110 and M5110e SAS/SATA controllers are 6 Gb SAS/SATA internal RAID controllers. This adapter and embeded controller are part

More information

Demartek Evaluation Accelerate Business Results with Seagate EXOS 15E900 and 10E2400 Hard Drives

Demartek Evaluation Accelerate Business Results with Seagate EXOS 15E900 and 10E2400 Hard Drives October 2017 Demartek Evaluation Accelerate Business Results with Seagate EXOS 15E900 and 10E2400 Executive Summary In today s world of digital transformation, organizations require high performance compute

More information

Webinar Series: Triangulate your Storage Architecture with SvSAN Caching. Luke Pruen Technical Services Director

Webinar Series: Triangulate your Storage Architecture with SvSAN Caching. Luke Pruen Technical Services Director Webinar Series: Triangulate your Storage Architecture with SvSAN Caching Luke Pruen Technical Services Director What can you expect from this webinar? To answer a simple question How can I create the perfect

More information

Hewlett Packard Enterprise HPE GEN10 PERSISTENT MEMORY PERFORMANCE THROUGH PERSISTENCE

Hewlett Packard Enterprise HPE GEN10 PERSISTENT MEMORY PERFORMANCE THROUGH PERSISTENCE Hewlett Packard Enterprise HPE GEN10 PERSISTENT MEMORY PERFORMANCE THROUGH PERSISTENCE Digital transformation is taking place in businesses of all sizes Big Data and Analytics Mobility Internet of Things

More information

Best Practices for SSD Performance Measurement

Best Practices for SSD Performance Measurement Best Practices for SSD Performance Measurement Overview Fast Facts - SSDs require unique performance measurement techniques - SSD performance can change as the drive is written - Accurate, consistent and

More information

Using SMR Drives with Smart Storage Stack-Based HBA and RAID Solutions

Using SMR Drives with Smart Storage Stack-Based HBA and RAID Solutions White Paper Using SMR Drives with Smart Storage Stack-Based HBA and RAID Solutions October 2017 Contents 1 What Are SMR Drives and Why Are They Used?... 1 2 SMR Drives in HBA or RAID Configurations...

More information

SUPERTALENT ULTRADRIVE GX(SLC)/GX(MLC) PERFORMANCE ANALYSIS WHITEPAPER

SUPERTALENT ULTRADRIVE GX(SLC)/GX(MLC) PERFORMANCE ANALYSIS WHITEPAPER SUPERTALENT ULTRADRIVE GX(SLC)/GX(MLC) PERFORMANCE ANALYSIS WHITEPAPER 2.5 SATA-II SOLID STATE DRIVE Copyright Informa on: Copyright, Super Talent Technology. All rights reserved. Rev 1.3 March 2009 Page

More information

Presented by: Nafiseh Mahmoudi Spring 2017

Presented by: Nafiseh Mahmoudi Spring 2017 Presented by: Nafiseh Mahmoudi Spring 2017 Authors: Publication: Type: ACM Transactions on Storage (TOS), 2016 Research Paper 2 High speed data processing demands high storage I/O performance. Flash memory

More information

SUPERTALENT UPSTREAM

SUPERTALENT UPSTREAM SUPERTALENT UPSTREAM PCI EXPRESS SOLID STATE DRIVE Copyright, Property of Super Talent Technology. All rights reserved. The information and specification provided in this document should be used for comparative

More information

SOFTWARE GUIDE VT-100. imageraid Series Storage System. (Text-based User Interface)

SOFTWARE GUIDE VT-100. imageraid Series Storage System. (Text-based User Interface) SOFTWARE GUIDE VT-100 imageraid Series Storage System (Text-based User Interface) SOFTWARE GUIDE VT-100 imageraid Series Storage System (Text-based User Interface) Fujitsu Europe Limited Restricted Rights

More information

High Performance SSD & Benefit for Server Application

High Performance SSD & Benefit for Server Application High Performance SSD & Benefit for Server Application AUG 12 th, 2008 Tony Park Marketing INDILINX Co., Ltd. 2008-08-20 1 HDD SATA 3Gbps Memory PCI-e 10G Eth 120MB/s 300MB/s 8GB/s 2GB/s 1GB/s SSD SATA

More information

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA IBM SAP International Competence Center, IBM Germany Version 1.3, September 2015 isicc@de.ibm.com

More information

Switched SAS. Sharable, Scalable SAS Infrastructure. Terry Gibbons, Director Software Planning and Strategy, LSI Corporation.

Switched SAS. Sharable, Scalable SAS Infrastructure. Terry Gibbons, Director Software Planning and Strategy, LSI Corporation. White Paper A B S T R A C T As application intelligence and new techniques for safeguarding data emerge, the subject of bringing storage closer to the server arises. Direct connection to external storage

More information

Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware

Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware openbench Labs Executive Briefing: March 13, 2013 Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware Optimizing I/O for Increased Throughput and Reduced

More information

Frequently Asked Questions. s620 SATA SSD Enterprise-Class Solid-State Device

Frequently Asked Questions. s620 SATA SSD Enterprise-Class Solid-State Device Frequently Asked Questions s620 SATA SSD Enterprise-Class Solid-State Device Frequently Asked Questions Q: What about advanced data protection? A: In mission-critical enterprise and datacenter applications,

More information

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units Quick Installation Guide Version A July 2010 Revision History Version and Date Version A, July 2010 Initial

More information

Supermicro All-Flash NVMe Solution for Ceph Storage Cluster

Supermicro All-Flash NVMe Solution for Ceph Storage Cluster Table of Contents 2 Powering Ceph Storage Cluster with Supermicro All-Flash NVMe Storage Solutions 4 Supermicro Ceph OSD Ready All-Flash NVMe Reference Architecture Planning Consideration Supermicro NVMe

More information

LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN

LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN Russ Fellows Enabling you to make the best technology decisions November 2017 EXECUTIVE OVERVIEW* The new Intel Xeon Scalable platform

More information

ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5110 and M5110e SAS/SATA controllers for IBM System x are part of the IBM ServeRAID M Series family

More information

Intel Solid State Drive Data Center Family for PCIe* in Baidu s Data Center Environment

Intel Solid State Drive Data Center Family for PCIe* in Baidu s Data Center Environment Intel Solid State Drive Data Center Family for PCIe* in Baidu s Data Center Environment Case Study Order Number: 334534-002US Ordering Information Contact your local Intel sales representative for ordering

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

MUS- INDNGFF60XXXXX(3)

MUS- INDNGFF60XXXXX(3) Please visit us at www.maximustek.com/en for more information. MUS- INDNGFF60XXXXX(3) Maximus NGFF 60mm Industrial Solid State Drive Data Sheet Version 1.1 Aug, 2013 Revision History Revision Date Description

More information

Persistent Memory. High Speed and Low Latency. White Paper M-WP006

Persistent Memory. High Speed and Low Latency. White Paper M-WP006 Persistent Memory High Speed and Low Latency White Paper M-WP6 Corporate Headquarters: 3987 Eureka Dr., Newark, CA 9456, USA Tel: (51) 623-1231 Fax: (51) 623-1434 E-mail: info@smartm.com Customer Service:

More information

SELECTION GUIDE. Storage Solutions. broadcom.com

SELECTION GUIDE. Storage Solutions. broadcom.com SELECTION GUIDE Storage Solutions broadcom.com The amount and variety of data produced by contentrich Internet, cloud and enterprise applications poses unprecedented challenges for data centers of all

More information

HP visoko-performantna OLTP rješenja

HP visoko-performantna OLTP rješenja HP visoko-performantna OLTP rješenja Tomislav Alpeza Presales Consultant, BCS/SD 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Performance

More information

iscsi STORAGE ARRAYS: AND DATABASE PERFORMANCE

iscsi STORAGE ARRAYS:  AND DATABASE PERFORMANCE iscsi STORAGE ARRAYS: EMAIL AND DATABASE PERFORMANCE OUR FINDINGS The responsiveness and capacity of a company s email and database infrastructure rely heavily on the underlying storage subsystem. In Principled

More information