Page 1 of 1. Inst. Deptt; National Fertilizers Limited, Panipat Unit. Format for Summary of Rates to be filled by Tenderer in column C & D

Size: px
Start display at page:

Download "Page 1 of 1. Inst. Deptt; National Fertilizers Limited, Panipat Unit. Format for Summary of Rates to be filled by Tenderer in column C & D"

Transcription

1 Inst. Deptt; National Fertilizers Limited, Panipat Unit Format for Summary of Rates to be filled by Tenderer in column C & D Summary Sheet S. No. ANNEXURE Total Amount in Figures (Rs) Total Amount in Words (Rs) A B C D 1 Ann. I 2 Ann. II 3 Ann. III Total Page 1 of 1

2 ANN./ DESCRIPTION Unit Total ITEM Inst. Deptt; National Fertilizers Limited, Panipat Unit Format for Schedule of Rates to be filled by the tenderer in columns E, F & G Ann. I Piping, Tubing and Allied Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity I-1.1. Removal of piping alongwith fittings and necessary clamps & supports a) Carbon steel size upto 1/2" MR b) Carbon steel size 3/4" MR c) Carbon steel size 1" MR d) Stainless steel size upto 1/2" Sch.40 & above. MR e) Stainless steel size 1" Sch.40 & above. MR I-1.2. Installation, supporting, clamping / welding & hydraulic testing of piping complete with fittings etc. as per standards a) Carbon steel size upto 1/2" MR b) Carbon steel size 3/4" MR c) Carbon steel size 1" MR d) Stainless steel size 1/2" Sch. 40 & above. MR I Removal of piping alongwith fittings and necessary clamps & supports including cutting/welding job. a) G.I. pipe size upto 1/2" MR b) G.I. pipe size 3/4" MR c) G.I. pipe size 1" MR d) G.I. Pipe 2" MR e) S.S. Sch.10 size 1/2" MR Page 1 of 7

3 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity f) S.S. Sch.10 size 3/4" MR I Installation of piping, supporting, clamping / welding & hydraulic testing of piping complete with fittings etc. as per standards. a) S.S. Sch.10 size upto 1/2" MR b) S.S. Sch.10 size 3/4" MR c) S.S. Sch.10 size 1" MR d) S.S. Sch.10 size 2" MR I Removal of PVC covered single copper tubing along with fittings & necessary clamps and supports. a) size 6 mm or 1/4" OD MR b) size 10 mm OD MR I-3.2. Laying, clamping, supporting and testing of PVC covered single copper tubing complete with fittings and connections, on trays / angles / ducts. a) size 6 mm or 1/4" OD MR b) size 10 mm OD MR I-4.1. Removal of S.S.tubing and necessary clamps & supports. a) size 6 mm OD MR b) size 10 mm OD MR c) size 12 mm OD MR I-4.2. Laying, clamping, supporting & testing of SS tubings complete with fitting & connections on trays/ angles/ducts. Page 2 of 7

4 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity a) size 6 mm OD MR b) size 10 mm OD MR c) size 12 mm OD MR I-5.1 Removal of multi-polythene tube bundles complete with identification & connections etc. a) size 7 core MR b) size 12 core MR. 5.0 I-6.1. Removal of steam tracing tubings along with fittings & necessary clamps, supports and the insulation. I-6.2. Laying,clamping,supporting and testing of steam tracing tubing complete with fittings, connections and fixing of steam traps, stainers and valves. MR MR I-7.1 Removal of instrument mounting pipe stanchions. a) L Type 15.0 b) T Type 15.0 I-7.2. Fabriction and installation of pipe stanchion as per standards, for mounting of instruments including cutting / welding jobs. a) L Type 30.0 b) T Type 50.0 I-8.1. Removal of mainfolds and necessary clamps & supports a) Pressure gauge 5.0 b) D/P Transmitter 5.0 c) Pressure switch 5.0 Page 3 of 7

5 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity d) Draft gauge 5.0 I-8.2. Fabriction,Erection and testing of manifolds as per standards including cutting / welding jobs. a) Pressure gauge 5.0 b) D/P Transmitter 5.0 c) Pressure switch 5.0 d) Draft gauge 5.0 I-9.1. Removal of shielded/unshielded, electrical / Thermocouple cables including cutting of clamps etc. a) size 2 x 1.5 Sq mm armoured MR b) size 3 x 1.5 Sq mm armoured MR c) size 4 x 1.5 Sq mm armoured MR d) size 24 x 1.5 Sq mm armoured MR I-9.2. Laying,clamping,testing,identification and connection of sheilded / unshielded electrical / thermocouple cables on trays/ angles / ducts / trenches. a) size 2 x 1.5 Sq mm armoured MR b) size 3 x 1.5 Sq mm armoured MR c) size 4 x 1.5 Sq mm armoured MR d) size 7 x 1.5 Sq mm armoured MR e) size 12 x 1.5 Sq mm armoured MR f) size 24 x 1.5 Sq mm armoured MR Page 4 of 7

6 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity I- Removal of control panel, with Instruments, including necessary cutting of associated structures (measurement will be as per Panel front - area) Sq.MR. 6.0 I- Installation of control panels, without Inst., including erection of associated structures (measurement will be as per the front area of panel) including cutting / welding jobs. I Removal of angle iron / perforated trays including cutting of clamps and supports. This includes lifting of existing cables / tubes, wherever required. Sq.MR. 6.0 a) Trays size upto 50 mm wide MR b) Trays size above 50 mm upto 100 mm wide MR c) Trays size above 100 mm upto 150 mm wide MR d) Trays size above 150 mm upto 200 mm wide MR e) Trays size above 200 mm upto 300 mm wide MR f) Angle iron size upto 25 mm MR g) Angle iron size above 25 mm upto 50 mm MR I- Erection,Laying,supporting of angle iron / perforated trays including clamping of existing cables / tubes, including cutting / welding jobs. a) Trays size upto 50 mm wide MR b) Trays size above 50 mm upto 100 mm wide MR c) Trays size above 100 mm upto 150 mm wide MR d) Trays size above 150 mm upto 200 mm wide MR e) Trays size above 200 mm upto 300 mm wide MR Page 5 of 7

7 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity f) Angle iron size upto 25 mm MR g) Angle iron size above 25 mm upto 50 mm MR h) Channels size upto 100 mm MR I- Removal of Junction boxes including cutting of supports / frame, if required. a) Pneumatic junction box 3.0 b) Pneumatic controller box 2.0 c) Thermocouple junction box 10.0 d) Electrical junction box 10.0 I- Installation of junction boxes after fabraction & erection of proper frame including termination of exisiting tubes / cables as per drawing including cutting / welding jobs. a) Pneumatic junction box 2.0 b) Thermocouple junction box 7.0 c) Electrical junction box 10.0 I- Panel (thickness upto 5 mm) cutting, with well finished edges, for installation of instruments. I- Fabrication of surface finished MS blank plate (thickness upto 5mm) for fill up of panel cut outs. (Measurement will be as per front area). Sq.Cm Sq.Cm I-14 Fabrication of Hylum / Bakelite sheet board upto 10 mm thickness, including mounting of relay, relay base, toggle switch, fuse holder, lamp holder, elemax terminals(measurement will be as per front area). a) size upto 1000 Sq.Cms Page 6 of 7

8 ANN./ DESCRIPTION Unit Total ITEM Rate in Figures (Rs.) Rate in words (Rs.) Total Amount (Rs.) Rate X Quantity I-15 Drilling of lamp holders / push buttons / toggle Switch holes of dia. upto 30 mm on panel sheet thickness upto 8mm. I-16 Fabrication of panel board of M.S. sheet, thickness upto 3 mm, with angle iron supports for mounting of gauges / Instruments including cut-out as per drawings (Measurement will be as per front area). 7.0 a) Area upto 1000 Sq.Cm I-17 Fabriction & erection of MS / GI / Al sheet upto 3mm thick cover/ canopy / shade for instruments, including supports, as per drawings (Measurement will be as per front area). including cutting / welding jobs. a) size upto 1000 Sq.Cm b) size above 1000 SqCm. but upto 3000 SqCm I-18 Welding of joints of impulse pipe, pipe fittings, flanges, Isolation valves to arrest leakage TOTAL Ann. I Page 7 of 7

9 ANN./ ITEM DESCRIPTION UNIT Total Inst. Deptt; National Fertilizers Limited, Panipat Unit Format for Schedule of Rates to be filled by the tenderer in columns E,F & G Ann. II Field Instrumentation related Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity II-1.1 Removal of solenoid valves, including electric & pneumatic connections and removal of associated structures. a) Explosion Proof 40.0 b) Non - Explosion Proof 40.0 II-1.2. Installation of solenoid valves including electric & pneumatic connections and supports. a) Explosion proof 40.0 b) Non - Explosion proof 40.0 II-2.1. Removal of on - line rotameters including accessories and associated structers, if required. a) Direct Type Rotameter b) Transmitter Type Rotameter 5.0 II-2.2. Installation of on - line rotameters with accessories and proper supporting. a) Direct Type Rotameter 10.0 b) Transmitter Type Rotameter 5.0 c) Glass Tube rotameterfor chlorination system 3.0 II-3.1. II-3.2. II-4.1. Removal of Mass /Turbine Flow-meter /ultrasonic flow meter including electric connections Installation of Mass / Turbine Flow meter/ Ultra sonic flow meter including electric connections Removal of Orifice plate, venturi, flow nozzle etc from pipe line a) For pipe line size upto 8" and pressure rating upto 600# 4.0 II-4.2. Installation of orfice plate, venturi, flow nozzle etc in pipe line. cutting welding job included. a) For pipe line size upto 8" and pressure rating upto 600# 4.0 Page 1 Of 8

10 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity II-5.1. Removal of control valves along with accessories from the pipe line / bonnet. a) Size upto 3" and pressure rating upto 600# II-5.2. Installation and testing of control valves on supports alongwith mounting of accessories. a) Size upto 3" and pressure rating upto 600# II-6.1. Removal of power cylinder with accessories including removal of air connections and supports etc II-6.2. Mounting of power cylinder with accessories including provision of air connections and supports etc.including cutting / welding jobs. II-7.1. Removal of Control Valve Accessories II-7.2 Installation of Control Valve Accessories 10.0 II-8.1. II-8.2. Removal of Limit switches including electrical connections & supports etc. Installation of Limit switches including glanding, electrical connections & supports etc II-9 Replacement of actuator diaphragm of DOPO / DOPC Valves including leak & stroke check etc. a) Size upto 2" 50.0 b) Size above 2" & upto 4" 40.0 c) Size above 4" & upto 6" 35.0 II-10 Replacement of bottom diaphragms & air sealing O Rings of DOPO / DOPC valves including stroke & leak check etc. a) Size upto 2" 50.0 b) Size above 2" & upto 4" 35.0 c) Size above 4" & upto 6" 40.0 II Removal of level gauges including drain valves etc. a) Above 600 # pressure rating 12.0 b) Below 600 # pressure rating 12.0 Page 2 Of 8

11 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity c) Tubular type 6.0 d) Magnetic type 2.0 II Installation of level gauges including drain valves etc. a) Above 600 # pressure rating 15.0 b) Below 600 # pressure rating 20.0 c) Tubular type 5.0 d) Magnetic type 2.0 II Removal of Level switch including cable glands & connections etc. a) Magnetic type 5.0 b) Direct mounted float type 5.0 II Installation of level switch including mountings, glanding and electric connections etc. a) Magnetic type 5.0 b) Direct mounted float type 5.0 II Removal of level indicator / transmitter / controller alongwith accessories, elect. / pneumatic / process connection etc. a) Float & tape type including float guide, wire, pulleys, taps & piping etc., if required. 2.0 b) D/P Transmitter including purge pipe. 5.0 c) Displacement type including float chamber d) Level Transmitter Radar type with cage assembly. 5.0 II Installation of level indicator / transmitter / controller alongwith accessories elect. / pneumatic / process connections etc. a) Float & tape type including float guide, wire, pulleys, taps & piping etc., if required. 2.0 b) D/P Transmitter including purge pipe. 4.0 Page 3 Of 8

12 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity c) Displacement type including float chamber d) Level Transmitter Radar type with cage assembly. 5.0 II II Removal of electrical speed indicator from the panel, including electrical connections. Installation of electrical speed indicator on the panel, including electric connections II Removing of pressure/vacuum/ differtional pressure/ receiver gauges with or without snubbers. a) Without Siphon b) With Siphon 10.0 II Installation of Pressure / Vacuum / differtional pressure / receiver gauges with or without snubbers as per schedule. a) Without Siphon b) With Siphon 10.0 II Removal of diaphragm seal pressure / differential pressure gauges. a) Direct mounting type 25.0 b) With SS Capillary 10.0 II Installation of diaphragm seal pressure / differential pressure gauges. a) Direct mounting type 25.0 b) With SS Capillary with proper laying & clamping II Removal of temperature gauges. a) Rigid stem type 5.0 b) With capillary including removal of clamps 1.0 c) With screwed thermowell 2.0 Page 4 Of 8

13 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity d) With flanged thermowell 2.0 II Installation of temperature gauges. a) Rigid stem type 5.0 b) With capillary including removal of clamps 1.0 c) With screwed thermowell 2.0 d) With flanged thermowell 2.0 II Removal of local switches alongwith electrical connections etc. a) Pressure 5.0 b) Temperature 5.0 II Installation of local switches including support & connections. including cutting / welding jobs. a) Pressure 5.0 b) Temperature 5.0 II-19.1 Removal of pressure transmitter alongwith electrical / pneumatic connections etc. a) Diaphragm seal type with capillary 10.0 b) Pressure & Vacuum Transmitter 50.0 II-19.2 Installation of pressure transmitter alongwith electrical / pneumatic connections etc. a) Diaphragm seal type with capillary 10.0 b) Pressure & Vacuum Transmitter 50.0 II Removal of flow transmitter alongwith electrical / pneumatic connections etc. a) Ultra - Sonic type 2.0 Page 5 Of 8

14 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity b) Diaphragm seal D.P.Transmitter 20.0 c) Differential Pressure Transmitter 30.0 II Installation of Flow transmitter alongwith electrical / pneumatic connections etc. a) Ultra - Sonic type 2.0 b) Diaphragm seal D.P.Transmitter 20.0 c) Differential pressure transmitter 30.0 II II II Removal of mercury filled temperature transmitter with capilary and other accesseries. Installation of mercury filled temperature transmitter with capilary and other accesseries. Removal of electronic instruments including electrical / pneumatic connection etc a) I / P Converters 15.0 b) P / I Converters 5.0 II Installation of electronic instruments including electrical / pneumatic connection etc. a) Flow Transducer 1.0 b) I / P Converters 15.0 c) P / I Converters 5.0 II II Removal of Receving indicating controller alongwith electric / pneumatic connections etc. Installation of receving indicating controller alongwith electric / pneumatic connections etc II Removal of temperature indicator / Recorder / Scanner including all connections. indentification & tagging of wire connections. a) Single point 2.0 Page 6 Of 8

15 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity b) Multi points 2.0 II Installation of temperature indicator / Recorder / Scanner including all connections.indentification & tagging of wire connections. a) Single point 2.0 b) Multi points 2.0 II-26.1 II-26.2 II II II Removal of Alarm Annunciators including all connections. Installation of Alarm Annunciators including all connections. Removal of Air filter regulator including necessary supports & connections. Installation of Air filter regulator including necessary supports & connections. Removal of Thermowell assembly a) Screwed type 10.0 b) Flanged type 20.0 II Installation of Thermowell assembly. a) Screwed type 10.0 b) Flanged type 20.0 II-29.1 II-29.2 Removal of oilers including necessary supports & connections from inst. air lines. Installation of oilers including necessary supports & connections for inst. air lines II-30.1 Removal of Vortex flowmeter / Mass flowmeters / magnetic flow meter with integral / remote electronic unit. II-30.2 II-31.1 Installation of Vortex flowmeter / Mass flowmeters/ magnetic flow meter with integral / remote electronic unit. Removal of ph. meter with electronics & elect connections II-31.2 Installation of ph. meter with electronics & elect. Connections II-32.1 a) Removal of Conductivity meter with cell & connection 3.0 Page 7 Of 8

16 ANN./ ITEM DESCRIPTION UNIT Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount (Rs.) Rate X Quantity b) Removal of conductivity cell & connection. II-32.2 a) Installation of Conductivity meter with cell & connection b) Installation of conductivity cell & connection. II-33.1 II-33.2 Removal oftemperature transmitter alongwith electrical / pneumatic connections etc. Installation of Temperature transmitter alongwith electrical / pneumatic connections etc. II-34.1 Removal of Hydrastep with electrical connections II-34.2 Installation of Hydrastep with electrical connections II-35.1 Removal of Hydrastep electrodes II-35.2 Installation of Hydrastep elctrodes II-36.1 Removal of GC / Analysers II-36.2 Fixing of GC / Analysers II-37.1 Removal of Gas Detectors II-37.2 Fixing of Gas Detectors II-38.1 Removal of proximity probes / Proximity switches II-38.2 Fixing of proximity probes / Proximity switches TOTAL Ann. II Page 8 Of 8

17 Inst. Deptt; National Fertilizers Limited, Panipat Unit Format for Schedule of Rates to be filled in by the Tenderer in columns E,F & G Ann III Assistance in Execution of ANN./ ITEM DESCRIPTION Unit Total Rate in Figures (Rs.) Rate in Words (Rs.) Total Amount(Rs.) Rate X Quantity III III-1-a III-1-b III-1-c III-1-d Assistance for execution of intermittent maintenance jobs, short shutdown / unforseen, Annual Turnaround jobs. Upkeep and cleaning of various instrumentation equipments installed in different plants on as and when required basis Skilled Labour for Welding jobs. Mandays 50.0 Unskilled labour Mandays Skilled Labour for rigging jobs Mandays 40.0 Skilled Labour for Inst. Maintenance jobs Mandays III-1-e Semi Skilled Labour for Inst. Maintenance jobs Mandays TOTAL Ann. III Page 1 of 1

BOQ CUM RATE SCHEDULE FOR C AND I WORKS AT 3x 500 MW APCPL JHAJJAR UNIT 1TO 3 TENDER NO. BHEL/NR/SCT/JHAJJAR/CNI/662

BOQ CUM RATE SCHEDULE FOR C AND I WORKS AT 3x 500 MW APCPL JHAJJAR UNIT 1TO 3 TENDER NO. BHEL/NR/SCT/JHAJJAR/CNI/662 PANELS / CONSOLES / RACKS 1 2 CONTROL CABINETS FOR S.G. (750L X 2355H X 750W) CONTROL CABINETS FOR T.G. (750L X 2355H X 750W) No. 164 No. 121 3 4 5 6 7 8 9 10 11 12 13 14 CONTROL CABINETS FOR MMI (750L

More information

Industrial Wet/Wet Differential Pressure Transducer

Industrial Wet/Wet Differential Pressure Transducer Industrial Wet/Wet Differential Pressure Transducer With High Over Pressure Capacity mv/v Output 0-5 Vdc Output 4-20 ma Output Model MD1-002DV Model MB1-100DV L 735 Basic Unit 1 bar = 14.5 psi 1 kg/cm

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

Clamp-On Digital Multimeters

Clamp-On Digital Multimeters Clamp-On Digital Multimeters GS-Mark EN61010-1 Approval Voltage Category III 600 V, Pollution Degree II AC/DC Current Clamp Highly Accurate 1999, 2500, 3999, 4300 Counts Resolution MAX, Data Hold, PEAK,

More information

Digital Panel Meters

Digital Panel Meters Digital Panel Meters For, Process, Voltage and Current DP63000 Starts at 81 DP63000B-E, 90, Thermocouple Inputs RTD Inputs Programmable Offset Selectable F or C with 1 or 0.1 Degree Resolution 3 Selectable

More information

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls.

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls. MI 330 UNIVERSAL PROCESS CONTROL TRAINER OBJECTIVE To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls. FEATURES

More information

Front Load Single Sensor

Front Load Single Sensor INFICON Front Load Single crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The front load design allows for easy insertion of

More information

Model 332 Differential Pressure Transmitter

Model 332 Differential Pressure Transmitter Model Differential Pressure Transmitter USERS GUIDE Please read carefully before using. Manufactured by: FURNESS CONTROLS LIMITED Beeching Road, Bexhill, East Sussex, TN9 LJ, England. Telephone (044) 706

More information

SECTION THERMAL UTILITY METERING INTERFACE

SECTION THERMAL UTILITY METERING INTERFACE SECTION 25 33 13 THERMAL UTILITY METERING INTERFACE GENERAL 1.1 SUMMARY A. Section includes metering and monitoring for interface points for utility chilled water, hot water, and steam fed to each building,

More information

Front Load Single Sensor

Front Load Single Sensor INFICON Front Load Single crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The front load design allows for easy insertion of

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

FLUOR. SmartPlant Implementation Team SPECSHEETS. Copyright 2012 Fluor Corporation all rights reserved

FLUOR. SmartPlant Implementation Team SPECSHEETS. Copyright 2012 Fluor Corporation all rights reserved FLUOR SPECSHEETS SmartPlant Implementation Team Copyright 2012 Fluor Corporation all rights reserved New SPI Spec Libraries Petrochemical Spec Library (SPI 2009 Library for SPI 2007.zip) Biopharma Spec

More information

Performance!Nxt Release

Performance!Nxt Release June 04, 2018 Performance!Nxt Release 12.7220 Flowserve is pleased to announce the latest release of Performance!Nxt (P!Nxt), the industry's foremost Control Valve Sizing, Selection and Project Management

More information

Front Load Dual Sensor

Front Load Dual Sensor INFICON Front Load Dual crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The dual sensor provides a backup crystal and is essential

More information

Pipe fittings and flanges, sockets for bayonet locks

Pipe fittings and flanges, sockets for bayonet locks Data Sheet 909750 (909725) Page 1/7 Pipe fittings and flanges, sockets for bayonet locks for temperatures up to 600 C for different fitting lengths simple installation and replacement pressure-tight sealing

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before working with the product.

More information

Cool Drawer Dual Sensor

Cool Drawer Dual Sensor The Cool Drawer Dual Sensor is designed for use in critical processes where it is desirable to have a second crystal in the vacuum chamber. Water cooled, cast stainless steel sensor body, two Cool Drawer

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before

More information

SUPPLEMENTARY PROTECTORS

SUPPLEMENTARY PROTECTORS SUPPLEMENTARY PROTECTORS WMS Series Starts at 16 75 1, 2, 3 Pole Models 1 to 30 Amp Ranges 3 Different Trip Curves to Choose From CSA 22.2 WMS1C20SP, 16.75, shown smaller than actual size. WMS2C20SP, 33.50,

More information

Item 620A Multi-Way Sanitary Ball Valve

Item 620A Multi-Way Sanitary Ball Valve R Item 0A Multi-Way Sanitary Ball Valve 00 WOG/ PN : /"-" SPECIFICATION * Body & end caps quality investment casting * Regulation (EC) No. / 00; (EU) 0/0 * Available in stainless steel or carbon steel

More information

Purpose of Today s Presentation

Purpose of Today s Presentation Metering, Monitoring, and Verification APPA Institute for Facilities Management February 6, 2014 Purpose of Today s Presentation To provide a broad understanding of: Metering installation and application

More information

Parts Manual Kleen Sweep 32R Rider Sweeper

Parts Manual Kleen Sweep 32R Rider Sweeper Parts Manual Kleen Sweep 32R Page 2 Table of Contents Side broom R.H., part 1... Side broom R.H., part 2... Front wheel drive... Accelerator... Steering... Seat group... Group of main sweeper roller, part

More information

DM28 - Economical Digital Process and Strain Gauge Panel Meters

DM28 - Economical Digital Process and Strain Gauge Panel Meters DM28 - Economical Digital Process and Strain Gauge Panel Meters TRANSDUCERS Easily scaled in any engineering units from -19999 to 99999 Large 18mm (.71 ) high red or green display Front panel MIN, MAX

More information

What Can You Automate? We Sell Robots

What Can You Automate? We Sell Robots AUTOMATION SOLUTIONS What Can You Automate? We Sell Robots Let Numatic Engineering s Value Add Services help keep your resources focused on your company s core business. Assembly Manufacturing Outsourcing

More information

Dishmachine Division Please call for pricing or

Dishmachine Division Please call for pricing or Dishmachine Division Please call for pricing -00-- or -00-5- ELECTRICAL BOX Page 0 and PLUMBING Page WRAPPER Page - PAN Page -5 STAND Page and KLE--HL Convertible Dishwashing Machine Part No. 05 5 5 0

More information

Sputtering Sensor ADVANTAGES

Sputtering Sensor ADVANTAGES The INFICON is specifically designed for use in any sputtering process. The sensor body and cooling tubes are gold plated beryllium copper for maximum cooling efficiency in the sputtering environment.

More information

Specification. Radiamatic Detectors and Accessories

Specification. Radiamatic Detectors and Accessories 4/92 Page 1 of 8 Radiamatic Detectors and Accessories Specification Function The Radiamatic temperature detector generates an emf proportional to the temperature of the object sighted. It is used with

More information

Solenoid Valves PN16 for gas flow interception

Solenoid Valves PN16 for gas flow interception s 7 684 INTELLIGAS Solenoid Valves PN16 for gas flow interception E... 2 way solenoid valves, threaded or flanged connections, brass or bronze body. 12V DC or 230V AC coil with manual reset. Normally Open

More information

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The DigitalFlow GC868 clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

Expandable Modular Data Acquisition System inet-400 Series

Expandable Modular Data Acquisition System inet-400 Series Expandable Modular Data Acquisition System inet-400 Series inet-555 665 Complete Starter System USB 2.0 High Speed Data Acquisition Hardware for Windows XP SP2, Vista or 7 (XP/VS/7) Analog and Digital

More information

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow Oil & Gas Control Control every move Pressure Temperature Level Flow Barksdale Oil and Gas - The Challenge today Oil & Gas Today Worldwide economic growth, depletion of oil reserves, and continued investment

More information

STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT INSTRUMENTATION AND CONTROLS

STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT INSTRUMENTATION AND CONTROLS STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT 220 - INSTRUMENTATION AND CONTROLS Prepared By: Daniel Miller Revised By: Daniel Miller 4/5/12 CANINO SCHOOL OF ENGINEERING

More information

Features: Quality Testing and Documentation

Features: Quality Testing and Documentation 1 The Yokogawa Falcon Series Dual Chamber Orifice Assembly YFOM-DC, is suitably designed for on-line retraction and inspection of orifice plates in process full flow and pressure conditions. The orifice

More information

HIGH PERFORMANCE STEPPER DRIVES

HIGH PERFORMANCE STEPPER DRIVES HIGH PERFORMANCE STEPPER DRIVES WITH AC POWER SUPPLY STAC6 Series Starts at 535 AC Power Supply Configuration Software and Programming Cables Included! Current Output.5 to 6. A 9 to 135 Vac Input Configurator

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL DX SERIES SNOW PLOW FOR SERIES SNOW PLOWS SERIAL NUMBERS AFTER DX0000 00 Sno-Way International 0G TABLE OF CONTENTS Page HYDRAULIC SYSTEM (DX)... POWER PACK FRAME... 3 BLADES... LIFT

More information

Beam Position Monitor For High Energy Particle Beams

Beam Position Monitor For High Energy Particle Beams Beam Position Monitor For High Energy Particle Beams Features 16 by 16 strip ionization chamber sensor High vacuum compatible Small insertion length (152.4 mm) Robust thin steel foil vacuum windows Very

More information

Spare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7

Spare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Spare part catalogue 0020037555.03 GB 03/2007 Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Content General view of sheet Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing

More information

TDSMLG2010R01 Magnetic Level Gauges & Level Transmitters

TDSMLG2010R01 Magnetic Level Gauges & Level Transmitters Magnetic Level Gauges provides clear, high clarity indication of liquid level. Magnetic Level Gauges are principally designed as an alternative to glass level gauges. MLGs are now widely used in all industries

More information

selection of special materials is available to handle almost any fluid.

selection of special materials is available to handle almost any fluid. For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications

More information

INTEGRATED STEPPER DRIVES/MOTORS WITH ADVANCED FEATURES AND CONTROL OPTIONS. ADVANCED FEATURES Auto Set-Up:

INTEGRATED STEPPER DRIVES/MOTORS WITH ADVANCED FEATURES AND CONTROL OPTIONS. ADVANCED FEATURES Auto Set-Up: STEPPER DRIVES INTEGRATED STEPPER DRIVES/MOTORS WITH ADVANCED FEATURES AND CONTROL OPTIONS STM Series Starts at $ 417 Configuration Included! Current Output 0.5 to 5.0 A Configurator TM configuration Configurable

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only

More information

Atlas Copco. Dryers BD 480. Parts list. From following serial No. onwards: APF

Atlas Copco. Dryers BD 480. Parts list. From following serial No. onwards: APF Atlas Copco Dryers BD 480 Parts list From following serial No. onwards: APF 56 875 Copyright 0, Atlas Copco Airpower n.v., Antwerp, Belgium. Any unauthorized use or copying of the contents or any part

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Low-Profile Modular Crescent Cuber Models KML-351MAH KML-351MWH A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71267 Issued: 5-9-2008 Revised: 10-13-2014

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches For control circuits, types ACW and ADW Presentation Pressure switches type ACW and ADW are switches for control circuits, with an adjustable differential.

More information

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

This is an economic model, especially suitable for instruments with ¼ port connection. Not detachable to repair.

This is an economic model, especially suitable for instruments with ¼ port connection. Not detachable to repair. Diaphragm seals - Stainless steel d. seals ¼ - PVC diaphragm seals ¼ - Stainless steel d. seals ½ - PVC diaphragm seals ½ - Easy-to-clean diaphragm seals - High pressure diaphragm seals - Low pressure

More information

SYLLABUS FOR PLUMBING & SANITARY TRADE

SYLLABUS FOR PLUMBING & SANITARY TRADE SYLLABUS FOR PLUMBING & SANITARY TRADE Duration at Skills Training Institute (Spread in three months) : 600 Hrs 1. Introduction to ITI : 3 Hrs 2. Introduction to the Trade : 3 Hrs 3. Introduction to Trade

More information

MANUFACTURING ELECTRICAL AND PLC PANEL BOARD

MANUFACTURING ELECTRICAL AND PLC PANEL BOARD Profile No.: 1 NIC Code: 27104 MANUFACTURING ELECTRICAL AND PLC PANEL BOARD 1. INTRODUCTION: Simplification of engineering and precise control of manufacturing process can result in significant cost savings.

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL 8 SERIES SNOW PLOW FOR SERIAL NUMBERS AFTER 8D100000 00 Sno-Way International 9100G TABLE OF CONTENTS PAGE DEFLECTORS... POWER PACK... HYDRAULIC POWER UNIT... LIFT CYLINDER... ANGLE

More information

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET -PORT SEAT VALVES PN WITH FLANGED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In boiler, district heating and refrigeration plants, cooling towers, heating groups, in ventilation and air-handling units as

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM. G Rajabaskaran Vice Chairman

TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM. G Rajabaskaran Vice Chairman TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM 1 G Rajabaskaran Vice Chairman Nagman is an ISO 90001:2008 certified company and serving the global market since 1972 Our calibration lab is accredited

More information

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE FEATURES: AIR or STACK MONITOR THREE CHANNEL SIMULTANEOUS MEASUREMENT DETECTOR VERIFICATION CAPABILITY USING GAS & SOLID SOURCES EASY DETECTOR SYSTEM CALIBRATION WITH BUILT-IN CALIBRATION INTERFACE INTERNAL

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

H.A. Phillips Inventory Overstock Liquidation List

H.A. Phillips Inventory Overstock Liquidation List H.A. Phillips Inventory Overstock Liquidation List ALL PRICES HAVE BEEN REDUCED All Items subject to verification of stocking. Items are sold as is. Please contact the factory (630-377-0050) for more information.

More information

Cool Drawer Single Sensor

Cool Drawer Single Sensor The Cool Drawer Single Sensors allow crystal installation into the sensor from the side, convenient for systems with insufficient room for front load crystal installation. The Cool Drawer Single Sensor

More information

RT2E Compact temperature switch Explosion proof

RT2E Compact temperature switch Explosion proof ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,

More information

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS Table of Contents A... 2 B... 2 C... 3 D... 4 E... 4 F... 4 G... 4 H... 4 I... 5 J... 5 K... 5 L... 6 M... 6 N... 6 O... 7 P... 7 R... 7 S... 8 T... 9 U... 10 V... 10 W... 10 A ADAPTERS AMPLIFIERS ATTENUATORS

More information

Solutions to the Most Challenging Environments

Solutions to the Most Challenging Environments Solutions to the Most Challenging Environments Short Catalog Feb, 2017 AM-2300 Multi-Input, Multi-Parameter Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity,

More information

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter

More information

ULTRASONIC, CRUSH, MANUAL, ZEBRA, & VERTICAL LOUVRE CUTTERS

ULTRASONIC, CRUSH, MANUAL, ZEBRA, & VERTICAL LOUVRE CUTTERS ULTRASONIC, CRUSH, MANUAL, ZEBRA, & VERTICAL LOUVRE CUTTERS IMPULSE WELDERS, END SEALER, INSPECTION HOISTS & ACCESSORIES Ultratab brings 10 plus years of experience and innovation to the window covering

More information

Municipal Line Card Automation Valves Measurement Process Control

Municipal Line Card Automation Valves Measurement Process Control Municipal Line Card Automation Valves Measurement Process Control We sell, apply, and service municipal-focused, high-quality specialty valves, measurement and automation products from best-in-class manufacturers

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215 HERZ STRÖMAX 7GM/GML/GR HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0 H Rp L SW L L Dimensions in mm

More information

Ultrasonic Flow Meter Brochure

Ultrasonic Flow Meter Brochure Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Thermocouple Signal Conditioners

Thermocouple Signal Conditioners Thermocouple Signal Conditioners idrx-tc Starts at 168 NEWPORT TM OMEGA manufactures thousands of thermocouple probes. Please see page 2 or visit omega.co.uk T/C Types J, K, T, E, R, S, B, N, J DIN 0.1

More information

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 ) The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

41K Series Cast Iron Commercial Steam Boiler

41K Series Cast Iron Commercial Steam Boiler 41K Series Cast Iron Commercial Steam Boiler PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number

More information

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com HALF SIZE MOISTURE PLUS DESCRIPTION PAGE CONTROL PANEL ASSEMBLY VIEW 4 PARTITION

More information

Precision temperature control/sensing

Precision temperature control/sensing PROBE TEMPERATURE SENSORS TE200 Series Precision temperature control/sensing FEATURES: Thermistor or Precision RTD Various configurations available Selection of enclosures Custom laser etching available

More information

Scanner 2000 Steam Mass Flow Transmitter

Scanner 2000 Steam Mass Flow Transmitter 3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures

More information

SPARE PARTS LIST CP COMPRESSOR. Model CPD CPD 75

SPARE PARTS LIST CP COMPRESSOR. Model CPD CPD 75 SPARE PARTS LIST CP COMPRESSOR Model CPD 75-00 EN 05 0 5 CPD 75 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? MAINTENANCE KITS STANDARD UNITS MOTOR-COMPRESSOR UNIT -7 AIR CIRCUIT -9

More information

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators 657 and 667 Size 30i - 76i Product Bulletin August 2016 Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators Fisher 657 and 667, size 30i to 76i, spring-opposed diaphragm actuators position the valve

More information

VAREC 5000/5010 SERIES FLAME ARRESTERS

VAREC 5000/5010 SERIES FLAME ARRESTERS VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

VorTek Pro-T Model Turbo-Pro Insertion Turbine Volumetric and Mass Flow Meters. Instruction Manual

VorTek Pro-T Model Turbo-Pro Insertion Turbine Volumetric and Mass Flow Meters. Instruction Manual 101 CAL-BENCH Instruction Manual Chapter 1 Introduction VorTek Pro-T Model Turbo-Pro Insertion Turbine Volumetric and Mass Flow Meters Instruction Manual Document Number M-000-00020 Rev 02/2014 8475 W

More information

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve ARI-PREDU - ANSI Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling

More information

Variable Area Flowmeters Installation Instructions G Series and M Series

Variable Area Flowmeters Installation Instructions G Series and M Series Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety

More information

Inductive Cylinder Position Sensors

Inductive Cylinder Position Sensors Inductive Cylinder Position Sensors 4-Wire DC (NPN and PNP) 2-Wire AC/DC Weld immune 250, 000, and 3000 psi designs C-Series F-Series Rating (psi) Probe Diameter Inductive Cylinder Position Sensors Pepperl+Fuchs

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor

More information

DIN-Rail Mounted Ultrasonic Flow Meter

DIN-Rail Mounted Ultrasonic Flow Meter DIN-Rail Mounted Ultrasonic Flow Meter The ultrasonic flowmeter is a transit-time fixed type flowmeter and can be as ultrasonic heat meter. Its installing way is standard din-rail mounted and have a very

More information

Blower Purge Air Dryers

Blower Purge Air Dryers Blower Purge Air Dryers PB-250 to PB-750 Parts List November 2013 2 Table of contents 1 PB - 250... 4 2 PB - 325... 6 3 PB - 400... 8 4 PB - 500... 10 5 PB - 650... 12 6 PB - 750... 14 7 Control Panel...

More information

CURRICULUM FOR SIX MONTH CERTIFICATE COURSE FITTING & PLUMBING UNDER DEVELOPMENT. Prepared By CURRICULUM DEVELOPMENT CELL

CURRICULUM FOR SIX MONTH CERTIFICATE COURSE FITTING & PLUMBING UNDER DEVELOPMENT. Prepared By CURRICULUM DEVELOPMENT CELL CURRICULUM FOR SIX MONTH CERTIFICATE COURSE IN FITTING & PLUMBING UNDER DEVELOPMENT Prepared By CURRICULUM DEVELOPMENT CELL INSTITUTE OF RESEARCH, DEVELOPMENT, TRAINING,U.P., KANPUR-208002 SIX MONTH CERTIFICATE

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or

More information

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority From Design to Installation, Appleton is The Switchrack Authority With over 80 years in the industry, Appleton is one of the first and the most respected names in custom switchracks for hazardous and adverse

More information

Process Control and Instrumentation Technology Model: PCT-200

Process Control and Instrumentation Technology Model: PCT-200 Process Control and Instrumentation Technology Model: PCT-200 Introduction The PCT-200 Process Control and Instrumentation rig provides a self-contained process control system which is representative of

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing.

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing. Stainless steel hygienic butterfly valves. F for imperial tubing. F for metric tubing. Features Keystone technology. Quarter turn operation. Isolation or regulation control. Equal percentage characteristics.

More information

BFW Traveler: Assembly and Alignment Procedure Serial Number: BFW # / VC # / WC # / Base #

BFW Traveler: Assembly and Alignment Procedure Serial Number: BFW # / VC # / WC # / Base # BFW Traveler: Assembly and Alignment Procedure Serial Number: BFW # / VC # / WC # / Base # NOTE - This document: 1. records the assembly and alignment steps for the LCLS Undulator Beam Finder Wire (BFW).

More information

Connect Electricians' tools, consumables and enclosures

Connect Electricians' tools, consumables and enclosures Connect Electricians' tools, consumables and enclosures 220 Tooling and consumables including electricians' hand tools, electrical insulation tapes, cable pulling socks, morse hole saws & accessories

More information

AHC System. Specifications. Series MA210 MA310 Positioning Max. transportable mass

AHC System. Specifications. Series MA210 MA310 Positioning Max. transportable mass AHC System Series Automatic exchange of robot hand tools, FMS (flexible manufacturing system) implemented for assembly lines. The robot hand tools change automatically to accommodate workpieces of different

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JUL0-TVT-OKC SERIES

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE Taylor Valve MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JAN00-TVT-OKC

More information

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9 100Led 760 / SixVac 801 / 760 / 2c 801 Micro INSTRUCTION MANUAL Digivac 760 Series Models 100Led 760 100P / 760 100P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro Ranges 0 to 760 Torr 0 to 19.99 Torr 0 to 29.9 inches of mercury The Digivac

More information

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current) Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current) SENSORS Document Part Number 551020 Revision K Product

More information

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6 Page 1 of 6 PART 1 GENERAL 1.01 DESCRIPTION A. Purpose 1. This section covers central cooling water meters for use in the Owner's central cooling water systems. 1.02 QUALIFICATIONS A. Approved manufacturers

More information