BOWMONK 2000 OPERATING MANUAL
|
|
- Shauna Collins
- 5 years ago
- Views:
Transcription
1 BOWMONK 2000 OPERATING MANUAL BOWMONK 2000 Components Pedal Force Transducer: The Pedal Force Transducer (PFT) is a strain gauge sensor that shows the forces necessary to stop the vehicle in Newton. Connect the (PFT) using the plug located at the left corner under the handle of the Bowmonk When conducting the test the (PFT) is positioned over the brake pedal. Carry Handle: To allow for easy carrying of the Bowmonk Battery charger (Plug Pack): The battery charger is used to recharge the Bowmonk 2000 battery. This unit Is plugged into the main power source and the socket into the Bowmonk The Plug Pack must be 16 Volt AC at 1300Milli Amp. Bowmonk Operating manual Page 1 of 17
2 LCD: This is a 16 character back-lit one line LCD and is used to view the input and test results. LED`S: The Bowmonk 2000 has two LED s. The Red LED will show when the battery is being charged. The Green LED will show when the Bowmonk 2000 is ON. Printer Cover: The printer cover is to protect the paper and to provide the means to tear off the paper with the printed results. Direction of the Test: The arrow on the front panel must be pointing in the direction of travel when conducting brake OR acceleration tests. Pedal Holder: The pedal holder is used to keep the pedal sensor (pedal force transducer) attached to the Bowmonk 2000 when not in use. Unit Cover: The cover and base each have a non-slip neoprene foam pad for better grip. The use of seatbelts to hold the unit should not be needed. The unit has a cover that is removable but note that it can be clipped under the unit for storage during testing. If the cover fits too loosely you can simply bend the cover s lugs as needed. Bowmonk Operating manual Page 2 of 17
3 Changing Printer Ribbon and Paper Paper Change: Open the Bowmonk 2000 printer cover, place a new paper roll in the paper holder and feed paper into the printer slot and press Paper Feed key. When paper has come through the top of the printer, feed the paper through the slot in the printer cover and click back in place. Additional paper rolls can be obtained from your Bowmonk 2000 dealer or local store. We recommended the use of single ply paper. Two ply paper can be used however the second copy, depending on the quality of paper used, may not be of the same quality as the top copy. Refer to page 6 FN 9 for further details. Ribbon Change: Open the Bowmonk 2000 cover. Push down where shown on ribbon cartridge. Cartridge should then lift up. Before inserting new ribbon cartridge, check ribbon adjuster on the cartridge in position, press down on both ends, cartridge should then click into place. Battery Charging: The Bowmonk 2000 has a high performance battery charging system to suit its internal lead acid battery. The unit is designed to allow for constant trickle battery charging. The battery is best looked after both for lifetime and number of prints per day by charging as often as long as possible. The unit should be charged at least every 3 months even if it is in storage to maintain the battery chemicals. The Bowmonk 2000 does not draw a large amount of current. However, a power drain occurs when you use the printer therefore it is important to place the unit on charge, at all times, when not in use. During operations, if the battery voltage drops to a low level a warning will be indicated on the L.C.D. display. Bowmonk Operating manual Page 3 of 17
4 TO CHARGE BATTERY - Plug power pack into a V power source and Plug Pack connector into Bowmonk 2000 socket and switch on at power point. Positioning Unit in the Vehicle Figure 1- Position of the Bowmonk Place Bowmonk 2000 on the front passenger side in a horizontal position either on the front passenger seat or on the floor. The Bowmonk 2000 must be close to level. If on the seat, use seat belt to prevent unit from sliding during braking. 2. The cover can be clipped to the base of the unit during testing - its nonslip rubber will give a stable contact surface. 3. The arrow on the Bowmonk 2000 must be facing the direction of travel. 4. If using the PFT, place the pedal force transducer on the brake pedal. It simply slips over the pedal. Be careful when you drive as the PFT sensor increases the height of the pedal. Bowmonk Operating manual Page 4 of 17
5 Operating the Bowmonk 2000 Unit To Turn Machine ON Press the key marked [ on ] [ off ]. The Bowmonk 2000 will print a small script showing the current date, time and the date when the Bowmonk 2000 is due for Recalibration. If the Power up Banner has been turned off it will print a short piece of blank paper. To Turn Machine OFF The Bowmonk 2000 can be turned off by pressing the [ on ] [ off ] key until the unit beeps. - The Bowmonk 2000 will automatically turn off approximately 12 minutes after printing the test. On each minute after the 8 th the unit will beep to let the operator know that auto-power off is imminent unless a key is pressed. Function Keys To use the function keys Press the function key marked [ Fn ]. When the screen shows Function? press the key below the function indicated in red. Use the Enter Key to Change Settings Press the [ Enter ] key to select your choice. To accept a setting Press [ Begin ]. After you accept it, the unit stays in that selected setting even when turned off. Fn 0 REPRINT This function will reprint a test just done or from the memory. Fn 1 DISPLAY DATE This function displays the current date in the machine and is a view only facility. Press the [ Enter ] key to go back to Bowmonk 2000 display. Fn 2 DISPLAY TIME This function displays the current time and is a view only facility. Press the [ Enter ] key to go back to Bowmonk 2000 display. Bowmonk Operating manual Page 5 of 17
6 Fn 3 DAYLIGHT SAVINGS This is an ON/OFF setting to adjust for summer time. Press the [ Enter ] key to change setting and the [ Begin ] key to accept it. Fn 4 UNIT DISPLAY The Bowmonk 2000 can be set to display G force as %G or G or m/sec^2. Press the [ Enter ] key to change setting and the [ Begin ] key to accept it. Typically it should be set for %G. Fn 5 VIEWING NEWTONS AND G FORCE The screen shows the current pedal force in Newton s, i.e. ON is 850N depending on pressure applied. It also shows the current deceleration, i.e g to +1.00g. If you tilt the machine in the direction of the arrow you will notice a change in the G force. Press the [ Enter ] key to go back to Bowmonk 2000 display. Fn 6 CURRENT BATTERY LEVEL When this is selected the current battery level is shown as a %. As batteries are chemically based the measurement of capacity is not directly available. For a truer value do a test print prior to this display. Press the [ Enter ] key to go back to Bowmonk 2000 display. The Bowmonk 2000 will warn of low battery conditions during use. Fn 7 INTERNAL SELF-TEST Result is a pass or fail. If the unit fails this test consult your supplier. Fn 8 KEYPAD DIAGNOSTICS This function allows you to press a key and display it on the screen to confirm its operation. Press the [ Fn ] key twice to exit this mode. Fn 9 SELECTS ONE OR TWO REPORTS This function allows you to choose between printing a single report when using the two part carbon paper or printing a double report when using single paper. Press the [ Enter ] key to change setting and the [ Begin ] key to accept it. Fn A DISPLAY ANGLE This option will display the current machine angle. Fn B BACKLIGHT To switch the LCD backlight On & OFF. Fn D DELETE Use this function to delete tests stored in memory. Bowmonk Operating manual Page 6 of 17
7 Fn G GRAPH DISPLAY This option allows you to print a graphical result of the Bowmonk 2000 test which is useful to analyse the vehicles suspension. For those doing frequent testing the graph may be turned off for faster printouts and paper saving. Press [ Y ] to print graph and [ N ] to turn graph off, or [ Begin ] to see current setting without changing it. Fn I INFO This function will print information related to all functions of the Bowmonk Fn M MODE OF OPERATION There are several settings which can be changed in this Function. See later in manual. Fn N NOISE This option is not available in this model. Fn R RECALL This function will recall tests stored in memory. See later in manual. Fn S STORE manual. This function will store tests in memory. See later in Fn T TEST PRINT This function prints a short script. Information such as the Road Traffic Authorities specifications and machine settings are displayed. Bowmonk Operating manual Page 7 of 17
8 Fn M MODE OF OPERATION Use this Function to: Select Mode of Operation Brake test Foot Brake test Acceleration Test Ext. Trigger Test Change settings Set Threshold Set Max Tilt Set Force Trigger Imperial Y/N Change Company Name Y/N Print PwrUp Banner Y/N Mode of operation The first Display will show the last selected mode of operation and will remain in this mode until changed. To change operation mode press [ Enter ] to scroll through the options and press [ Begin ] to confirm the selection. Change settings To change settings, (Threshold, Force Trigger, Max Tilt,) press [ Enter ] to scroll through the options. Press [ Begin ] when the item to be changed is displayed. Use the number keys on the keyboard to enter a new value and press [ Enter ] to store in memory. To change between Imperial and metric press Y or N depending upon the setting Displayed. The Bowmonk 2000 will remain in these settings until changed. Pwrup Banner When the Bowmonk 2000 is first turned on it prints out some information. To delete this Function press the [Enter] key until the words pwrup Banner? Y/N appears. Press [ N ] to turn this off or [ Y ] to turn back on. Bowmonk Operating manual Page 8 of 17
9 Entering Company Name The user s company name can be entered, and will appear near the bottom of each printout. Press the [ Enter ] key until you see Enter Name? Y/N. Press the letter [ Y ] and type in company name followed by the [ Enter ] key. The name is limited to sixteen characters in length. Fn S STORE Use this function to store the last test conducted in memory. 4 tests can be stored. The display will show Test : 1_ 2_ 3_ 4_ Press the number 1 to 4 to select the position to store the test. If a test has already been stored a solid Bar will appear on the right of the number. Choosing the same number will overwrite the last stored test Fn R RECALL Use this function to recall a test previously stored. The display will show Test : 1_ 2_ 3_ 4_ Press a number 1 to 4 to select the test you wish to recall. There must be a solid bar to the right of the number to indicate that a test has been stored there. To print a stored report, choose the report you want by pressing FN, R and the number. Then press FN and Reprint. Transferring Data to PC via a Download Smart Module (DSM) Conduct the test. When the test is finished the Display will show: Print Report? Y/N Press [ Y ] to print a report or N not to print a report. The Display will then show: Send to DSM? Y/N Bowmonk Operating manual Page 9 of 17
10 If you wish to send to a DSM insert the DSM in the RS232 communications port then Press [ Y ]. Connect the DSM to the Interface Box and connect the Interface Box to a Com Port in your PC. Ensure you have the Bowmonk 2000 PC Software running and download the data following the PC instructions. Also erase the data from the DSM following the PC instructions. NOTE 1: You can store up to 150 tests in the DSM Note 2: You can also download the data to a PC or Laptop following the same instructions. The Display must show. Send to a DSM? Y / N Press [ N ] if you do not wish to send the data to a DSM or PC or Laptop. Bowmonk Operating manual Page 10 of 17
11 Test Setup Step 1 Press the [ Begin ] key. The Bowmonk 2000 will ask for the examiner s identification. The examiner should type in his/her identification code on the keypad. Once this is done press the [ Enter ] key. NOTE: If an incorrect letter/numeral is entered, it can be deleted by pressing the delete key [ Del ] on the keypad. Step 2 The Bowmonk 2000 will now ask for the vehicle registration. The examiner must type in the vehicle registration on the keypad. Once this is done press the [ Enter ] key. Only press [ Enter ] if you are ready to proceed. Make sure the vehicle is at a dead stop before you press [ Enter ]. The Bowmonk 2000 is now waiting for the test to commence. The LCD will display Waiting For Brake. The test may be cancelled at any time by pressing the [ Del ] key. Just hold down the [ Del ] key and the Bowmonk 2000 will complete the section of the report it is doing then it will stop. Conducting the Test First position and set-up the unit as described above. Testing a Vehicle s Service Brake (Foot Brake) Accelerate the vehicle to the specified speed, place foot on brake pedal and apply steadily and firmly until vehicle has come to a complete stop. If using the pedal sensor (PFT), change setting from BRAKE TEST to FOOT BRAKE TEST on Mode of Operation. Accelerate the vehicle to the specified speed, place foot on pedal sensor (PFT) and apply steadily and firmly until vehicle has come to a complete stop. NOTE: All tests are set to BRAKE TEST mode except when using pedal sensor (PFT) which should be set to FOOT BRAKE TEST. Testing a Vehicle s Hand Brake Follow the same procedures as for Service Brake. Do this test in accordance with vehicle manufacturers instructions and test authority requirements. Bowmonk Operating manual Page 11 of 17
12 Retest Once the Registration and Operator details are entered you can re-test the vehicle without re-entering all the data. The unit will ask, Do another Test? Y/N, select [ Y ] for yes and [ N ] for no. If the unit automatically turns off or the [ Begin ] key is pressed then all the data needs to be re-entered. Reprint Last Test The last test can be reprinted by pressing the Print key [ 0 ], this test is stored until any of the following occur: (a) (b) (c) (d) The unit is turned off The [ Begin ] key is pressed The BOWMONK 2000 mode is changed A self-test is performed Test Sequence Some customers like to enter all the data before they place the unit in the vehicle. This is OK provided that the final [ BEGIN ] or [ ENTER ] key press is done after the unit is stable in the vehicle. Cancelling a Printout During the printout of the test, it is possible to cancel the print. Just hold down the [ Del ] key. Bowmonk Operating manual Page 12 of 17
13 Test Print The Test Print shows the following information: Serial no The unit serial number is shown on the top and bottom border of the Print out. Software version number Shows the version of software in the Bowmonk 2000 Millennium eg. V1.0. Current Date and Time The date and time the print out was made. Next Calibration Date Is the date when the Bowmonk 2000 is due for recalibration. Last Months Test Is the number of test completed. Bowmonk 2000 See the appropriate section to change Bowmonk Operating manual Page 13 of 17
14 Interpreting Results The Bowmonk 2000 print out shows the following information: - Date and Time This is the data and time of the Brake-Test. Next Cal Date Date when Bowmonk 2000 is due for recalibration. Examiner Is the person who conducts the test. Rego This is the registration or VN number of the vehicle. Test Number This is the number of consecutive test that the unit has done. Bowmonk Operating manual Page 14 of 17
15 Graph Shows the performance of the vehicle during braking as per below. Decel Max Maximum g force during test. Average Decel Refers to cumulative g force over duration of test. Test Duration Time from the application of the brake to the vehicle coming to a stop. Speed of the Test The speed at the start of the brake application. Stopping Distance The distance travelled after applying brakes until vehicle stops. This is calculated using the average 20 mph Maximum Deceleration and extrapolated as if the vehicle were going 20 MPH regardless of the actual Speed of Test. This is calculated using the average deceleration. Performance Shows brake effort expressed as a percentage. This is also referred to as Braking Efficiency. Brake delay The time lag between the brake control being operated and the instantaneous brake effort. This value only has meaning if the PFT is used otherwise a default value is shown. Slope Angle of the brake tester during test. Signature This is the examiners signature. Company Name This is optional, see text. Explanation of graph Newton Scale The top axis on the graph refers to the amount of pedal pressure in Newton s required to stop the vehicle. Approx. 10 Newton s equals 1kg of force. The scale is adjusted based on the maximum Newton s. Bowmonk Operating manual Page 15 of 17
16 Newton Graphic The thin line on the graph refers to the Newton s or pedal pressure during test. Max Maximum Newton's during testing. Pk This is the Newton reading at Decel Max. Deceleration Deceleration is measured by g force. G Force Scale The bottom axis on the graph refers to g force. The scale is adjusted based on the maximum g force. (100 refers to 100% or 1g) G Force Graphic The thick line on the graph refers to the g force or deceleration during testing. Time Time is shown on the vertical axis and is measured in seconds. Bowmonk Operating manual Page 16 of 17
17 Trouble Shooting The following table indicates a number of possible problems and their solutions. PROBLEM CAUSE SOLUTION 1. No display on LCD Unit is switched off Press [ON] key Battery run down Recharge battery and retry. If the problem persists, contact Service 2. Printer not operating Battery run down Recharge battery or Faulty key Contact Service Unit repeating a printout Paper jam Clear jam or replace roll (possibly wrong paper has been used). 3. Functions not Faulty keys Contact Service Operating correctly 4. Sensor providing Faulty sensor Contact Service incorrect readings Faulty cable to pedal sensor 5. Battery not holding Faulty charger Contact Service its charge Faulty battery Contact service or use Prolonged charging Warranty A full 12 month warranty against defect. PLEASE NOTE: Deliberate or unintentional damage of the unit may result in the warranty becoming void. Likewise, it the unit is interfered with by anyone other than an authorised service agent, the unit will not be covered under this warranty. Calibration We recommend that the Bowmonk 2000 be calibrated every 12 months to ensure accurate operation. Bowmonk Operating manual Page 17 of 17
User Manual Version AUTOSTOP Heavy. I n V e h i c l e B r a k e T e s t e r
User Manual Version 8.19 AUTOSTOP Heavy I n V e h i c l e B r a k e T e s t e r Table of Contents AutoStop Heavy 1. UNPACKING AND FIRST TIME USE... 2 1.1 Activating your meter... 2 2. USE OF BATTERY CHARGER
More informationUser's Guide. For CarChip and CarChip E/X 8210 & 8220
User's Guide TM For CarChip and CarChip E/X 8210 & 8220 Product Number: 8210, 8220 Davis Instruments Part Number: 7395.064 DriveRight CarChip User s Manual Rev A (January 2, 2003) Davis Instruments Corp.,
More informationCF3000 Dealer Diagnostic Tool Instruction Manual
CF3000 Dealer Diagnostic Tool Instruction Manual Table of Contents: About the CF3000......3 Important Precautions......4 Components....5 Charging the CF3000......7 Licensing the CF3000.......8 Updating
More informationSAC / SHC / SHC-CH SERIES
This document hosted by: www.oldwillknottscales.com SAC / SHC / SHC-CH SERIES HIGH PRECISION COUNTING SCALE OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE July
More informationGI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566
GI-4000 User Manual Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 TEL: (850) 939-5222 FAX: (850) 939-0490 EMAIL: sales@kobetron.com WEB: www.kobetron.com "Testing Tomorrow's Technology Today" TABLE OF
More informationOperation Manual. snapshot. cuvettes. Pi-102 Luminometer
Operation Manual Pi-102 Luminometer snapshot cuvettes Version: 2.0 Hygiena International Ltd. January 2013 Contents Page 1. The instrument 3 1.1 Instrument details 1.2 Cuvette size to be used 1.3 Explanation
More informationATD-5493 Wireless Battery System Tester
ATD-5493 Wireless Battery System Tester For Testing 6V & 12V Vehicle Batteries individually & in Battery Packs. Also for testing 6V, 12V, 24V and 36V Charging & Starter Systems User Manual Remote Battery
More informationI. PANEL DESCRIPTION... 1
Table of Contents I. PANEL DESCRIPTION... 1 II. OPERATING INSTRUCTION... 7 1. MA OUTPUT... 7 1A. GENERAL OPERATION 4-20MA... 7 1B. SELECT 0-20MA OR 0-24MA... 8 1C. ENTER A VALUE LESS THAN 1... 9 2. % (PERCENTAGE)
More information1. Review the printer safety information in the Regulatory Compliance document provided with your printer.
QUICK REFERENCE This Quick Reference contains supply loading information and general care and maintenance procedures for the Monarch Pathfinder Ultra Platinum 6039 printer. For more detailed information,
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...
TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...
More informationX-431 Volkswagen Diagnosis. Table of Contents INTRODUCTION...1
Table of Contents INTRODUCTION...1 FEATURES...1 Advanced...1 Open...1 Integrative...1 Flexible...1 HARDWARE CONFIGURATION...2 PORTS AND INDICATORS...3 PRINTER OPERATION...4 Mounting Paper...4 Printing
More informationModel 8702 DP-CALC Micromanometer
Ventilation Testing/Balancing Model 8702 DP-CALC Micromanometer Operation and Service Manual 1980260, Revision F July 2006 Model 8702 DP-CALC Micromanometer Operation and Service Manual 1980260, Revision
More informationTTC Series Torque Tool Tester Operation Manual
TTC Series Torque Tool Tester Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationDFS Series User s Manual (5N-1000N Capacity)
DFS Series User s Manual (5N-1000N Capacity) REV 3.8 Table of Contents Table of Contents 2 Introduction 3 Before Use 3 Operation Overview 4 Powering the DFS 5 Using the DFS. 6 Fitting Accessories 6 Mounting
More informationUsing the Cashmaster you will notice some changes in the way you work:
User Manual CONTENTS Introduction. 1 Box items and guidelines... 2 Maintenance... 2 Charging.. 2 Warning... 2 Unpacking... 3 Keys and display... 4 Cashmaster Sigma 170... 4 The keypad..... 5 The screen.......
More informationNIDEC-SHIMPO INSTRUMENTS
Series FGE-XY Force Gauges Operation Manual NIDEC-SHIMPO INSTRUMENTS Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the
More informationOne (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.
Chapter 2 Specifications Data Recorded Frequency Response Transducer Microphone Memory Clock Timer Mode Display Keyboard Power On Log Printer Chart Width Chart Length Battery Operating Time External Battery
More informationService Technical Resources MUT-III. (Multi-Use Tester-III*) Quick Reference Guide
Service Technical Resources MUT-III (Multi-Use Tester-III*) Quick Reference Guide *Cart not included May, 2003 INTENDED USAGE OF MUT-III MUT-II role after MUT-III Launch MUT-III is an essential special
More informationARA FTS Flow Calibrator. Operation Manual August 1, 2016
ARA FTS Flow Calibrator Operation Manual August 1, 2016 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 1 2. GETTING STARTED 1 2.1. Navigation 1 2.2. Charge Battery 1 2.3. Set Date and Time 2 2.4. Plug-In
More informationUser manual. paper moisture meter humimeter RH5 with sword sensor
User manual paper moisture meter humimeter RH5 with sword sensor Version 2.0_en Schaller GmbH 2012 User manual short form Positioning the instrument Insert the sword-sensor into the stack for only approx.
More informationSR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual
SR200 GPS SPORTS WATCH Keeping you one step ahead User manual Congratulations on purchasing your Snooper RUN SR200 Your new Snooper RUN SR200 is packed with loads of great features. It uses the latest
More informationUNIVERSAL MOUNT USER GUIDE
UNIVERSAL MOUNT USER GUIDE TABLE OF CONTENTS OVERVIEW... 3 INSTALLATION... 4 Paper...4 Scanner...4 Tablet...5 CONNECTIONS... 6 Power...6 Cash Drawer...6 External PIN Pad...6 Connection Ports Maximum Ratings...6
More informationINSTALLATION & USER MANUAL
INSTALLATION & USER MANUAL MODELS EVMS & GSVMS with Rain Sensor 00--0 Fax: 0-- csm@wascoproducts.com www.wascoskylights.com Eastern Facility: Spencer Drive, Unit A, Wells, ME 000 Western Facility: Echo
More informationInstruction Manual. 24" and 48" Electronic Digital Level Model Nos &
7123H_Manuals 8/6/13 11:51 AM Page 1 24" and 48" Electronic Digital Level Model Nos. 1876-2400 & 1876-4800 Instruction Manual Congratulations on your choice of this Digital Level. We suggest you read this
More informationMultifunction Calibrator
Multifunction Calibrator Model CL TC - - - C V _ TECPEL CO., LTD. Features:. - (KΩ load, V Loop Supply). -.,-.V, -.V. K, J, E, T Thermocouple ( C and ). Frequency -.. Basic Accuracy. Easy Key-pad Operation.
More informationSeries FGE-XY Force Gauges Operation Manual
Series FGE-XY Force Gauges Operation Manual Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the temperatures can exceed 104
More informationFHD Driving Recorder E272S/S272W. Quick Start Guide
FHD Driving Recorder E272S/S272W Quick Start Guide 400-8401-030 www.polaroidcarcam.com 1 Introduction 1.1 Package Contents The package contains the following items. In case there is any missing or damaged
More informationAlcatel DECT 209 Wireless PBX System
Alcatel DECT 209 Wireless PBX System USER GUIDE 1 User Guide Index Contents 4 Installation 5 The Base 5 The Handset 6 Charger 6 Battery Cover 7 Handset Keys 7 LCD Icons 8 Standby Mode 8 Receiving a Call
More informationUsing the Cashmaster you will notice some changes in the way you work:
User Manual CONTENTS Introduction. 1 Box items and guidelines... 2 Maintenance... 2 Charging.. 2 Warning... 2 Unpacking... 3 Keys and display... 4 Cashmaster Sigma 170... 4 The keypad..... 5 The screen.......
More informationINSTRUCTION MANUAL C WA2 WELD ANALYZER
INSTRUCTION MANUAL 700215C WA2 WELD ANALYZER MICROPROCESSOR BASED Monitors ENTRON Controls, LLC. 1402 S. Batesville Road Greer, South Carolina 29650 (864) 416-0190 FAX: (864) 416-0195 www.entroncontrols.com
More informationacaia Coffee Scale Operation Manual
acaia Coffee Scale Operation Manual Using Your acaia Coffee Scale Identification The instructions in this operation manual apply to the acaia Coffee Scale. You have purchased a quality precision weighing
More informationINTRODUCTION. Notes (loose) Coins (loose, packaged) Using the Cashmaster you will notice some changes in the way you work:
User Manual CONTENTS Introduction.............. 2 Box items and guidelines... 3 Charging.. 3 Unpacking... 4 Warning... 4 The main parts of the Cashmaster... 5 Keys and display The keypad...... 6 The screen....
More informationUnit Test Calibration Training. (QL420+ & RW420) Mobile Printers
Calibration Training (QL420+ & RW420) Mobile Printers : Overview Unit test is software which is used with the QL and RW range of mobile printers and is used to do the following: Test and calibrate all
More information4 Leg Air +Hydraulic Leveling System
4 Leg Air +Hydraulic Leveling System Setup & Configuration Guide Operation Guide Air/Hydraulic FIRMWARE VERSIONS: CONTROLLER 2.18 FRONT SENSOR 2.6 REAR SENSOR 2.9 PNEUMATIC I/O MODULE 2.4 FIRMWARE VERSIONS:
More informationInstruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &
7640H-English_Manuals 12/11/13 4:18 PM Page 1 24" and 48" Waterproof Electronic Digital Level Model Nos. 1880-2400 & 1880-4800 Instruction Manual Congratulations on your choice of this Digital Level. We
More informationOPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 07
SCOPE This section is intended for the guidance of NDE personnel qualified in accordance with the requirements of M&NP Training and Qualification of Personnel. The inspection processes and procedures described
More informationQuick Guide v. 1.1 DeFelsko Corporation USA 2012
Quick Guide v. 1.1 Introduction The PosiTector Surface Profile Gage (SPG) is a hand-held electronic instrument that measures the peak-to-valley height of the surface profile of abrasive blast cleaned surfaces.
More informationSIGMATEST Operating Instructions
SIGMATEST 2.069 Software Version 3.12 Operating Instructions Registered trade-mark Contents 1. Introduction...4 2. Applications and Features...5 3. Getting Started...6 4. Measuring System Specifications...8
More informationScrolling USER MANUAL REMOTE CONTROL LED SIGN BOARD. *For 3Color Signs. QWERTY Keypad! / Effects Table / Button Functions / Trouble Shooting Guide NEW
Scrolling REMOTE CONTROL LED SIGN BOARD USER MANUAL *For 3Color Signs NEW QWERTY Keypad! / Effects Table / Button Functions / Trouble Shooting Guide Table of Contents Components List ---------------------------------------------------------
More informationRW Series Overview. Introduction
Thank you for choosing one of our Zebra RW Series Mobile s. These rugged printers will become productive and efficient additions to your workplace thanks to their innovative design. Because they are made
More informationCHEMINSTRUMENTS HIGH SPEED RELEASE TESTER MODEL HSR-1000 OPERATING INSTRUCTIONS
CHEMINSTRUMENTS HIGH SPEED RELEASE TESTER MODEL HSR-1000 OPERATING INSTRUCTIONS PRODUCT DESCRIPTION...2 UNPACKING...3 ASSEMBLY...4 KEY COMPONENTS...5 OPERATION...6 SAMPLE PREPARATION...8 EZ LAB SOFTWARE...9
More informationAWS-QC Torque Tester
AWS-QC Torque Tester USER'S GUIDE March, 2009 ADVANCED WITNESS SERIES, INC. 910 BERN COURT #100 SAN JOSE, CA 95112 (408) 453-5070 www.awitness.com CONTENTS 1 CONTENTS CONTENTS... 1 INTRODUCTION... 2 Description...
More informationComponent Tests User Manual
Component Tests User Manual February 2009 EAZ0007E70C Rev. C Trademarks Acknowledgements Snap-on, Scanner, Fast-Track, and MODIS are trademarks of Snap-on Incorporated. All other marks are trademarks or
More informationNIDEC-SHIMPO INSTRUMENTS
TTR Torque Tool Tester Operation Manual NIDEC-SHIMPO INSTRUMENTS 1) Overloading the transducer does not only damage the transducer but may break the transducer head and could result in injury! 2) Torque
More informationAbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples
AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples Product No. 475025 1. General Description The AbraScan RDS-1500 Test Strip Reader
More informationHandheld force display AE 703
Handheld force display AE 703 Original of Manual Marschnerstraße 26 01307 Dresden, Germany Phone +49 3 51 44 55 30 Fax +49 3 51 44 55 555 www.ast.de vertrieb.dd@ast.de 1 Contents 1. Scope of use... 1
More informationOperating Instructions
Operating Instructions for the WABCO Diagnostic Controller 446 300 320 0 with Program Card ECAS 4x2-A 446 300 521 0 or ECAS 6x2-A 446 300 527 0 or ECAS BUS-A 446 300 529 0 March 1996 Edition Copyright
More informationIntroduction Box items and guidelines... 2 Maintenance. 2 Charging... 2 Warning. 2. Guidelines... 3 Unpacking... 3
User Manual CONTENTS Introduction... 1 Box items and guidelines... 2 Maintenance. 2 Charging... 2 Warning. 2 Guidelines... 3 Unpacking... 3 Keys and display....... 5 The keypad....... 5 The screen.......
More informationEHC-03 Ultrasonic Thickness Gage
QUICK START GUIDE EHC-03 Ultrasonic Thickness Gage Software version x.x Liability Ultrasonic testing is a function of using the proper equipment (electronics, transducer, cable and couplant combination)
More informationTrouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution
Trouble Shooting Leveling Control Box 140-1224 Electric Jacks Copyright Power Gear Issued: January 2013 #82-L0524, Rev. OA Touch Pad LED Probable Cause Solution 1. On/Off LED will not light 2. Wait LED
More informationAlmex Optima Drivers Guide
Almex Optima Drivers Guide Issue Draft Date 03/11/08 Author LS Draft Page 1 of 10 03/11/08 Table of Contents Table of Contents ----------------------------------------------------- 2 Optima Layout Explained
More informationLL 32,000 LL 10,000 LL 24,000 LL 75,000 LL 79,000 LL 59,000 LL 15,000 LL 22,000 LL 24,000 LL 12,000. LL 22,000 Available colors LL 16,000
REMOTE CONTROL ORGANIZER REF 02001 MINI DRONE WITH CAMERA REF 02002 LL 75,000 BLUETOOTH SPORTS HEADSET REF 02007 Metal 4 set organizer Universal stand for all types of slim remote controls With anti-slip
More informationProduct Parts Front view... 2 Rear view... 2 Inside the product... 3 Scanner parts... 3 Control panel... 4
Table of Contents Product Parts Front view................................................................. 2 Rear view.................................................................. 2 Inside the product...........................................................
More informationUltraprobe 401 Digital Grease caddy Pro Instruction Manual
Version 1 1 Ultraprobe 401 Digital Grease caddy Pro Instruction Manual Version 1 2 Contents Instructions for Ultraprobe 401 Digital Grease Caddy Pro:... 3 Mounting the 401 Digital Grease Caddy to Grease
More informationMODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT
MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT Contains Operating and Programming Information Model ATV 4/6 Battery Powered Digital Vacuum Instrument ã 1996, Teledyne Electronic Technologies,
More informationPME 700 Demolition Stability Monitor
PME 700 Demolition Stability Monitor Operators Manual This guide describes operation of the PROLEC PME LIFTING AND MACHINE ENVELOPE SAFETY SYSTEM FOR CONSTRUCTION PLANT Model covered : PART No. MODEL
More informationELECTRONIC TORQUE METER ETM OPERATION INSTRUCTION
ELECTRONIC TORQUE METER ETM OPERATION INSTRUCTION Please read instruction carefully prior to first use! ELORA Werkzeugfabrik GmbH Am Blaffertsberg 33 D-42899 Remscheid 12 02 62 D-42872 Remscheid ( 49 )
More informationISP Tester. Operating Instructions
ISP Tester Operating Instructions Rev. 1.3 2 Table of Contents Overview of Operation...3 Connecting Test Cable to ISP Tester...4 Inserting Battery Pack...8 Turning on Main Power...9 Using the Touch Panel
More informationAdvanced Camcorder Support System. Instruction Manual
Advanced Camcorder Support System Instruction Manual PAG ORBITOR Advanced Camcorder Support System Instruction Manual CONTENTS SECTION PAGE 1 SAFETY 2 2 ASSEMBLY & OPERATION 3 3 PARTS AND ASSEMBLIES 9
More informationemedny POS Start Guide
New York State Department of Health (NYS DOH) Office of Health Insurance Programs (OHIP) emedny POS Start Guide VERIFONE Vx570 and Vx610 TERMINALS Publish Date:01/01/2013 Version 1.1 May 01, 2011 Version
More informationWingmate Rover Components
Congratulations on your new Wingmate Rover breathalyser. We hope you enjoy owning your Wingmate Rover breathalyser. If you have any questions regarding the unit or want to speak with us further, please
More informationRV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. THE USE OF THE GROUND CONTROL AUTO LEVELING SYSTEM TO SUPPORT
More informationMTX-A Temperature Gauge User Manual
MTX-A Temperature Gauge User Manual 1. Installation... 2 1.1 Gauge Mounting... 2 1.2 Temperature Sensor Mounting... 2 1.2.1 Changing the MTX-A s Gauge Bezel... 2 1.3 Main Gauge Wiring... 3 1.3.1 Single
More informationVIZTRAC. VIZTRAC User s Guide STANDARD FIXED HEAD 100' 130' 150' A. 200' 225' AM 100 AM 200 AM hz Built-In Sonde AM 140 AM 200B AM 240B
VIZTRAC 3807 Old Tasso Rd. NE Cleveland, TN 37312-5732 VIZTRAC User s Guide STANDARD FIXED HEAD 100' 130' 150' A 200' 225' AM 100 AM 200 AM 240 512hz Built-In Sonde AM 140 AM 200B AM 240B DVR Quick Start
More informationModel No INSTRUCTION MANUAL. Manual should be read prior to operation!
Model No. 15950 INSTRUCTION MANUAL Manual should be read prior to operation! CONTENTS 1) GENERAL 3 2) WORK PRINCIPLE AND STRUCTURE FEATURES 3 3) MAJOR TECHNICAL PARAMETERS 4 4) USE AND OPERATION 5 5) MAINTENANCE
More informationHP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter
HP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter This document applies to HP notebook computers. The keyboard, TouchPad, or ClickPad on your laptop is not working as expected:
More informationUSER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements
USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting
More informationQuick Start Guide. January EAZ0081L02A Rev. A
Quick Start Guide January 2014 EAZ0081L02A Rev. A Trademarks Snap-on and Vantage Ultra are trademarks of Snap-on Incorporated. All other marks are trademarks or registered trademarks of their respective
More informationMobilControl MC 4000 OWNER S MANUAL
MobilControl MC 4000 Hand Held Service instrument with data logger for pressure, min / max & differential pressure, temperature, flow / rpm and hydraulic horsepower OWNER S MANUAL 20 7 TERMINALS 7.1 Plugs
More informationTruckweigh. operators sheet STGGLOBAL.NET
Truckweigh operators sheet 1300 998 784 STGGLOBAL.NET FRONT PANEL FUNCTIONALITY The various screens and menus are accessed using the four buttons located around the LCD display, described briefly below.
More informationT4 series user s manual. Version: 1.1
Version: 1.1 Table of contents 1. Introduction...1 1.1 In the box...1 1.2 Printer Features...2 1.2.1 Front view...2 1.2.2 Rear view...2 1.2.3 Interior view...3 2. Getting start...4 2.1 Loading the ribbon...4
More informationDATE ( / 7. / 1. / / 3. / / 5. / 6. / TIME
ELIMINATOR 2000 INSTRUCTIONS Table of Contents 1. PRACTICE A. TREE Key 1. Change Full to Pro Tree 2. Change Tree Speed ( 4 tenths or 5 tenths) 3. Change Rollout Out Separate Full and Pro Tree 4. Change
More informationFrequently Asked Questions
Serene CL-60A Amplified Talking CID Cordless Phone with Slow-Play, Amplified Answering Machine Frequently Asked Questions Q: Base Charging Indicator is not on when handset is placed on the base. A: Move
More informationIntroduction. Chapter 2
The Vantage PRO unit (Figure 2-1) combines a digital and graphing multimeter, lab scope and ignition scope with a powerful diagnostic database. Figure 2-1 Vantage PRO This diagnostic database gives you
More informationCALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10
CALOG C A L I B R AT O R S CALOG - LC DISPLAY Loadcell Display English Users Manual Rev. 1.10 Table of Contents! Contents! 1.0 Introduction...2! 2.0 Getting Started...2! 2.1 Keypad...2! 2.2 Display...2!
More informationCONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...
2 CONTENTS - RW-2601P Series Caution... 4 1. Introduction... 5 2. Features... 7 3. Technical Specifications... 7 4. Explanation of Frontal Aspect... 9 5. Test Mode...11 6. Set Mode... 14 7. Calibration
More informationTD-700 FLUOROMETER SERVICE MANUAL
TD-700 FLUOROMETER SERVICE MANUAL July 1996 CONTENTS Page Section 1 INTRODUCTION 2 Section 2 PRELIMINARY CHECKS 3 Section 3 TROUBLESHOOTING GUIDE 5 A. Lamp (Fluorescent) 5 B. Lamp Heater 7 C. Fan 8 D.
More informationDivision Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)
Division Services 5680 E. Shelby Drive Memphis, TN 38141 PH (901) 366-4220 FAX (901) 365-3934 Model: DPAS-300 VERSION 5 Division Portable Bulk Load Accumulator Scale INDUSTRIAL Division Model DPAS-300
More informationCelltron Advanced Stationary Battery String Analyzer CTA-2000 and CTA-4000
Celltron Advanced Stationary Battery String Analyzer CTA-2000 and CTA-4000 INSTRUCTION MANUAL Table of Contents Introduction... 1 Safety instructions... 1 Important... 1 Guidelines... 1 About the analyzer...
More informationModel 897 Operating Tutorial Alternators
Model 897 Operating Tutorial Alternators MasterPower Switch MotorPower Switch Make sure that your 897 is connected to a 110VAC, 20A dedicated circuit. We recommend using a Square D HOM120HM or equivalent
More informationMINI-G RUGGED HIGH TECH 5V TO 19V CHARGER USER GUIDE
MINI-G RUGGED HIGH TECH 5V TO 19V CHARGER USER GUIDE YOU CAN: CHARGE NETBOOKS SLR CAMERAS TABLETS GOPROS SMARTPHONES GPS GAMES CONSOLE SMARTWATCHES AND MORE INDEX What s in the box Technical specifications
More informationPlease read this guide before using of the PowerShot A5. You will find instructions on how to use basic camera functions.
Please read this guide before using of the PowerShot A5. You will find instructions on how to use basic camera functions. Introduction Thank you for purchasing a Canon PowerShot A5, the easy-to-use, compact
More informationSAFETY PRECAUTIONS AND WARNINGS...
Table of Contents 1. SAFETY PRECAUTIONS AND WARNINGS... 1 2. TOOL INFORMATION... 2 2.1 TOOL DESCRIPTION... 2 2.2 SPECIFICATIONS... 3 2.3 ACCESSORIES INCLUDED... 3 2.4 ICONS... 4 2.5 KEYBOARD... 4 2.6 BATTERY
More informationOperation Manual. rev Charge then remove battery when stored for more than 1 week. Flow Finder MK2. Powered Flow Hood
Operation Manual rev-2017-04-20 Flow Finder MK2 Charge then remove battery when stored for more than 1 week Powered Flow Hood 1. Introduction The FlowFinder mk2 is the successor of the well-known FlowFinder
More informationDT-900 Techstrobe Operation Manual
DT-900 Techstrobe Operation Manual Remove battery pack prior to recharging. Do not use the adapter as an external source for the techstrobe. DT-900 handheld stroboscope operates at HIGH VOLTAGE inside
More informationA Guide on How to use the Canon Power Shot A 95 Digital Camera
A Guide on How to use the Canon Power Shot A 95 Digital Camera Preparing the Camera: 1. Open the battery cover and insert the batteries in the correct position. NEVER THROW THE BATTERIES AWAY. THEY ARE
More informationWalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8
15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 WalkLAB Professional Conductivity-TDS-Salinity Meter HC 9021 Operations Manual 0 INTRODUCTION
More informationAn energy metering system that gives flexibility, security and control. Century House, Roman Road, Blackburn, BB1 2LD
An energy metering system that gives flexibility, security and control 1 Contents 1. Before you get started...4 What s inside the box?...4 What is vpro2? Why do you have it? How does it work?...4 Liberty
More informationDCN Parliamentary Voting. Software User Manual en LBB 3575
DCN en LBB 575 GENERAL CONTENTS Chapter 1-1.1 About Chapter 2 - Getting Started 2.1 Starting 2.2 Using help Chapter - Preparing for a conference.1 The Preparation window.2 Working with script files. Creating
More informationMPB SERIES Electronic Balances. r1 v1.09. Operation Manual
MPB SERIES Electronic Balances r1 v1.09 Operation Manual CONTENT 1. Introduction 1 2. Key and display 2.1 Key Function 1 2.2 Display 1 3. Operation 3.1 Before use 2 3.2 Zeroing the display 2 3.3 Taring
More informationM-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES
M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES TABLE OF CONTENTS INTRODUCTION. 2 POWER SUPPLY. 4 INSTRUCTION FOR REPLACING BATTERIES 5 SPECIFICATIONS..
More information4-20 ma Current Data Logger
1 4-20 ma Current Data Logger OM-DL420 DATA LOGGER INSTRUCTIONS The OMEGA OM-DL420 Data Logger is a self-contained precision instrument for recording the current in a 4 20 ma loop. The OM-DL420 can store
More informationIDS-801 Series Compact Bench Counting Scale. User Manual
IDS-801 Series Compact Bench Counting Scale User Manual 1. INTRODUCTION... 3 1.1. Product Description... 3 1.2. General Features... 3 1.3. Safety Precautions... 3 2. INSTALLATION... 4 2.1. Unpacking...
More informationOwner s Manual Model Number
Owner s Manual Model Number 75-822 Features Include: 40 CB Channels 10 Weather Channels 5 Memory Channels Memory Scan Dual/Watch Portable and Mobile CB (2-in1) HI/LOW Power Auto Power Save Instant Ch 9.
More informationPrecision Motion Performance Computer Data Acquisition Instrument Accelerometer Owner s Manual
Precision Motion Performance Computer Data Acquisition Instrument Accelerometer Owner s Manual 1 VC4000 MSI Manual Introduction Table of Contents 1. INTRODUCTION... 4 Features... 5 What's Included... 6
More informationTest n Tag. Label Printing System. Instruction Manual 308A550. May Seaward Electronic Ltd. Issue 1.0
Test n Tag Label Printing System Instruction Manual 308A550 May 2003 2003 Seaward Electronic Ltd. Issue 1.0 Limited Warranty & Limitation of Liability SEAWARD Electronic Limited guarantees this product
More informationBF ENTRON LTD. Monitoring equipment. Weld Analyser WA2
BF ENTRON LTD. Monitoring equipment Weld Analyser WA2 M O N I T O R I N G E Q U I P M E N T Weld Analyser WA2 BF ENTRON Ltd. Building 80 The Pensnett Estate Kingswinford West Midlands DY6 7FQ Phone +44
More informationModel GX-2001 Data Logging Software. User s Guide
Model GX-2001 Data Logging Software User s Guide Part Number: 71-0056RK Edition: First Released: 6/29/2001 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects
More informationDWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT
c DWP-98 Series Counting scale User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION
More informationMANUAL PCE-123
www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk
More information