Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

Size: px
Start display at page:

Download "Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11"

Transcription

1 Peregrine Technology CO.,LTD. DSO Oscilloscope User Menu V1.1 Date: 2014/07/11

2 Index Safety Regulation Project Spec System Requirements Contents Exterior Appearance of DSO Host Installation Instructions Installing DSO Software Installing Driver Operating Instructions Function description of operating screen Function Description Probe Compensates Capacitor Correction

3 Safety Regulation Please completely read safety regulation before using oscilloscope to ensure fully aware of correct using methods and rules, and must comply with stipulation of safety regulation. Do not take the housing apart:taking the housing apart may cause electric shock risk and affect internal components resulting in damages. Please ground the probe to ensure good grounding:do not connect ground terminal to power terminal to avoid damaging oscilloscope. If oscilloscope is not used for a long time, please unplug the USB cable to save electricity. Do not use oscilloscope near the environment such as high temperature, humid and inflammable, etc. to avoid damages. 2

4 1. Project Spec Model DSO-2400 DSO-2200 Use One Channel Sampling Rate 400MS/s 200MS/s Use Two Channel Sampling Rate 200MS/s 100MS/s Bandwidth 100MHz 100MHz Channel 2 Input Impedance 1MΩ±1% // 20pF±5% Max. Input Voltage 40Vpk (DC + AC peak) Input Coupling AC, DC Vertical Resolution 8 bits Vertical Sensitivity 2mV/DIV to 5V/DIV (as step) Vertical Range 8 divisions Offset Level ±4 divisions Offset Increments 0.1 division DC Accuracy ±3% Time Base Range 200 ms ~ 5 ns Time Accuracy 25 ppm Time Display Range 10 Divisions Memory 2k points Trigger Type Rising, Falling, Delay-Trigger Trigger Mode Auto, Normal, Single Trigger Source CH1, CH2, Ext-Trig Trigger Level ±4 divisions Trigger Increments 0.1 division Measurement Vpp, Vmax, Vmin, Vmean, Period, Frequency Cursor Time difference, Voltage difference, FFT Frequency, FFT dbv Calibration Output 3.3V, 1kHz Accessories 100MHz probe (1x/10x) x2, Installation CD, USB2.0 cable 3

5 2. System Requirements PC Pentium 1.2G compatible, Pentium 2.0G CPU (or above) is better. PC memory above 64M bytes RAM At least 32M bytes disk space USB 2.0 port CD-ROM drive(only for software installation) Screen specification 640x480 VGA, 800x600 or 1024x768 is better. Microsoft Windows XP/Vista/Windows7 operating system Keyboard & mouse 4

6 3. Contents Item Quality Image 1 DSO-U2400 Oscilloscope 1 2 Probe 2 3 Type A to B USB Cable 1 4 Installation DVD 1 5

7 4. Exterior Appearance of DSO Host USB connector: The interfaceconnected DSO host to computer-based communication. Power indicator light: When power supply is normal, power indicator light will display red light signal. TRIG indicator light: When signal is successfully triggered, the green light signal will be flashing. CH 1: Channel 1 is the channel acquired by DSO host to measure external signal. CH 2: Channel 2 is the channel acquired by DSO host to measure external signal. PROBE COMP: When the probe corrects signal output 3.3V 1KHz square wave is used as reference signal to adjust the probe. GND: Grounded signal EXT TRIG: External trigger signal. When external signal is run, DSO will refer to input signal of the connector to decide when it will be triggered. 6

8 5. Installation Instructions 5.1. Installing DSO Software DSO software in the disk is attached to the machine, or please free downloads the software from the following website of Peregrine Technology CO.,LTD. Steps of software installation are as follows: Step. 1: Please firstly put the installation disk in CD-ROM driver and executes DSO_Setup.exe to install this application. Step. 2: Jump out of the installation screen as Fig.1 and click Next. Fig.1:Installation Screen 7

9 Step. 3: This page as Fig. 2 is installation path. If you would like to change the installation path of the software, click Browse and select required directory location to install in your computer. We propose to remain default and click Next to access to DSO installation process after setup is completed Fig.2:Selection Screen of Installation Path Fig.3:The screen of DSO installation process 8

10 Step. 4: After execution of installation process is completed you can jump out of the finished screen. The whole DSO software installation process is finished, and you can get DSO shortcut on the desktop. Fig.4:The screen of installation complete Step. 5: Using USB cable attached to the machine to connect DSO and PC 9

11 5.2. Installing Driver Step. 1: After using USB cable to connect to DSO and computer the computer will automatically detect new software and pop up window Found New Hardware Wizard. 10

12 Step. 2: Once selecting Install the software automatically and click Next. Found New Hardware Wizard will search for driver in the computer. The whole process of searching driver will take some time. Fig.5:Found New Hardware Wizard Fig.6:The screen of searching for the driver 11

13 Step. 3: After hardware installation wizard searches for the driver, it will install the driver automatically. A few operating systems will pop up the screen of Driver has not passed verification ; however, this notice will not affect usage and operation of DSO. You can select Continuing the installation to complete driver installation. Fig. 7: The screen of Driver has not passed verification Fig.8:The screen of completing driver installation 12

14 6. Operating Instructions 6.1. Function description of operating screen DSO operating screen as below figure can be mainly divided into four parts: 1. Waveform display area; 2. Channel switching area; 3. Main function selection area; 4. Subfunction selection area. The function of each part is described as follows. The details will be further explained in function description. 1. Waveform display area:it displays waveform measured by DSO and the current information set by DSO. 2. Channel switching area:it s used to switch required oscilloscope channels to control. 3. Main function selection area:it s used to set DSO system setup, including the information of screen size, waveform save, system setup and measured voltage, etc. 4. Subfunction selection area:it s used for more detailed setup to fit selection button of main funcation. Any selection button is matched with one set subfunction setup. 13

15 6.2. Function Description Channel Switch Button Channel switch button can help you to switch the channel you want to control. When the button displays red, it means all the relevant voltage and cursor operation will do the actions on the channel you selected. E.g. when you switch to CH2 to operate Volt/Div button, only waveform of CH2 will be changed on the screen. The channel has not been selected The channel has been selected VOLTS/DIV Knob Volts/Div knob is used to adjust tap position of voltage that the bottom left corner indicates voltage value on the current vertical axis each square. Move your mouse to Volts/Div knob and click left or right button of the mouse to amplify or reduce voltage values. Two small buttons - and + at bottom left and bottom right of Volts/Div knob also can be used to adjust voltage values. Voltage information at bottom right of waveform display screen indicates voltage resolution represented in vertical distance each square. E.g. example of voltage value 500mV each square represented as the above figure. 14

16 TIME/DIV Knob Time/Div knob is used to adjust time value in horizontal distance each square on DSO screen that the information similar to M 2µs is underneath the screen. It represents 2µs each square on the screen. Click left or right button of the mouse to amplify or reduce time value. Two small buttons - and + at bottom left and bottom right of Time/Div knob also can be used to adjust time values. Time information at underneath of waveform display screen indicates time resolution represented in horizontal distance each square. E.g. example of time value 2µS each square represented as the above figure. Main Function Selection Button The part in red box is 10 main function selection buttons as below figure, and explained respectively as follows. 15

17 RUN/STOP Run or stop DSO retrieve function. When retrieve function stops, the screen will stay at the final data retrieved. Trigger After clicking Trigger button you can find three options on function submenu as follows, respectively: Source:Triggered signal source that you may select CH1 or CH2 as the source. Slope: Set rising slope or falling slope to be a trigger signal. Mode:Auto, Normal and Single are three triggered modes. Auto: Waveform will be automatically retrieved after no trigger for a certain time. It s a common mode for ordinary oscilloscope. Normal: Waveform is retrieved for only successful trigger. Single: The action will stop once waveform is successful retrieved and stop update. It s used to retrieve fleeting signal. 16

18 CURSOR Cursor function is mainly used to measure time point and time difference or voltage point and voltage difference for two events occurred, which can acquire more precise information to analyze. When cursor function is run, two cursor lines can be found on DSO waveform display interface and are used to measure time or voltage values cursor-to-cursor. There re two options of vertical line (time) and horizontal line (voltage) for cursor function. When cursor is run, one solid line and the other dashed line will appear in waveform area of the screen. You can use cursor to drag these two cursor lines, which one line being dragged will become a solid line and the other dashed line. Cursor information with initials of the and will also appear at upper left of the waveform voltage value or time point indicated by cursor line. :Represents time difference or voltage different cursor-to-cursor Example for the values indicated at upper left of the above figure is the information between two cursor lines. 1.96us at upper right represents time point 1.96uS which yellow cursor line is located in. 2.04us represents time point which pink cursor line is located in. :-4.00u represents 4uS time difference in which two cursor lines are located. 17

19 MEASUREMENT FUNCTION Measurement function is mainly used to measure various information of input signal, through which we can see all parameters of the current signal from sub-function menu, such as frequency, cycle, maximum, minimum, amplitude and average value. We can get required information through the display of sub-function menu, or we can amend corresponding sub-function menu to display information through sub-function menu as below figure. When we push option button of sub-function under Measure function, information menu will pop up allowing us to select displayed information in the corresponding sub-function menu. When using Measure function, we firstly switch the required channel to measure and then select sub-function selection button for required information options to see this information on sub-function menu. 18

20 DISPLAY FUNCTION MENU We can setup various parameters for waveform display screen through Display function menu. E.g. whether channel waveform displays or not, and the way of signal coupling. Fig:Display function menu Chx Display:Whether waveform of CH1 or CH2 is displayed. Chx Coupling:Coupling setup is divided into AC coupling and DC coupling. When DC is setting, all signals will be retrieved. When AC is setting, signal will filter DC components but retrieve AC signals. Chx Probe:Setting turndown ratio of probe. When turndown ratio is setting 1:1 or 1:10, the corresponding setting must be done to show correct numerical value. 19

21 FFT:Analysis function of frequency spectrum. FFT source can be set CH1, CH2 or FFT function close through subfunction menu. When using FFT function, DSO can switch input time domain signal into frequency domain signal that we can observe energy distribution of input signal in each frequency band. Under FFT frequency spectrum node, we can mark frequency value through cursor line function of the Course. We can move cursor line to the highest power point of frequency spectrum signal as below figure. The information of cursor line at upper left indicates the frequency 1MHzat the highest energy point for input signal, which is same as signal frequency from the measurement of Measure. FFT Zoom:FFT Zoom function is to signify FFT signal, which is used to see more detailed frequency spectrum signal by amplifying 2X, 5X and 10X through sub-function menu. You can move the below scrollbar to select what you want to review. Fig:FFT frequency spectrum functio 20

22 PRINT Function Key Print function can print measured waveform through printer. When Print Function Key is push, print setup window will be popped up. You can select printer from pull-down menu of Name and click OK to print the measured waveform. Fig:Print setup 21

23 SAVE To File Function Key Measured waveform image file or data can be saved in the computer through Save to file function, which can be used for reference of data processing or comparison in the future. The current Save to file function can support two formats of bmp file and Matlab data file. SAVE:Save the measured signal as BMP file. Export to Clipboard:Temporarily save the measured waveform to RAM and select to paste as any format of image file on window Paint or any image processing software. Matlab:Save as Matlab data file (.m). After the signal is saved as.m file, Matlab software can be used to load the saved data for data processing. Note: Matlab is a pure one-dimensional array file and filename extension can be changed to.txt for the use of other programming languages. 22

24 System SETUP Function Key System setup function key is used for various parameters setup of DSO software. Language:Displayed language setting in DSO sub-function menu for three languages of English, traditional Chinese and simplified Chinese Color Setting:Color setting used for waveform, cursor line of the Course and background. Click color block for color setting of the object. Hot Key Setting:Hot key setting used for DSO software operation. Move mouse to the corresponding input of function setting ( No in the figure) and press required setting key to finish setup. Factory Setting:When selecting Factory Setting, all parameters of DSO software will return to default. Test Clock:Clock signal output when correction. When self-correction is required, this option is set as ON and connect probe to CLK pin. Setup Printer:Printer is used for Setup Printer. Printer Color:Printer Color is set to print selected color or black waveform by printer. 23

25 Fig:Color setting window Fig:Hot key setting window 24

26 DEMO When DSO hardware does not connect to the computer, the software will automatically access to display mode. The computer will self produce an analog signal to display on DSO software screen. SIZE Display screen size setting for DSO waveform. You can set a screen display size applicable to your waveform. Applicable options for various screen resolutions are proposed as follows: 320 x 240 applicable to more than 1024 x 768 screen resolution 400 x 320 applicable to more than 1024 x 768 screen resolution 500 x 400 applicable to more than 1280 x 1024 screen resolution 600 x 480 applicable to more than 1280 x 1024 screen resolution 700 x 560 applicable to more than 1650 x 1050 screen resolution 800 x 640 applicable to more than 1650 x 1050 screen resolution 25

27 7. Probe Compensates Capacitor Correction Notice: Set TEST CLOCK to be ON in SETUP function menu before probe correction. Step. 1:At first, we connect USB cable to the computer. Step. 2:We connect probe connector to measurement channel, hook PROBE COMP connector with test hook, and clamp GND with alligator clamp as below figure. 26

28 Step. 3:We adjust probe ratio to 10X, turning on DSO software and clicking voltage knob to 50mA that we can see waveform appeared in the display screen. Step. 4:Adjust trigger level to fix waveform in the display screen. 27

29 Step. 5:Use a complimentary flat blade screwdriver attached to the machine to turn adjusting knob on probe connector, and then you can see the square wave type on DSO to gradually become a complete square wave. Smooth square waves can be seen after adjustment is completed. 28

GDS-2000 Series. Features

GDS-2000 Series. Features GDS-2000 Series Features 200/100/60 MHz Bandwidth 2/4 Input Channels 1GSa/s Real-Time and 25GSa/s Equivalent-Time Sampling Maximum 25k Points Record Length Large 5.6-in TFT Color Display USB Host/Device:

More information

PCI-express data acquisition card DAQ0504M User Guide

PCI-express data acquisition card DAQ0504M User Guide PCI-express data acquisition card DAQ0504M User Guide Contents Safety information... 3 About this guide... 4 DAQ0504M specifications... 5 Chapter 1. Product introduction 1-1. Package contents...... 6.

More information

Manual imso-204x. RevOrig_

Manual imso-204x. RevOrig_ Manual imso-204x Manual Table of Contents Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software 1.40 Tool Tips Section 2 How it works 2.10 Menus

More information

Digital Storage Oscilloscope

Digital Storage Oscilloscope GDS-800 Series Digital Storage Oscilloscope GDS-800 Series at 60MHz/100MHz/150MHz/250MHz bandwidth with or chrome LCD display, are designed and built to meet the demands of a modern Digital Storage Oscilloscope

More information

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence WaveAce Oscilloscopes 40 MHz 300 MHz Debug With Confidence the tools and features for all your debug the tools and features for all your debug needs needs Key Features 40 MHz, 60 MHz, 100 MHz, 200 MHz

More information

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence WaveAce Oscilloscopes 40 MHz 200 MHz Debug With Confidence THE TOOLS AND FEATURES FOR ALL YOUR DEBUG NEEDS Key Features 40 MHz, 60 MHz, 100 MHz, and 200 MHz bandwidths Sample rates up to 2 GS/s Long Waveform

More information

User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual

User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual Certificate of Product Warranty This product s warranty, provided by our company, covers a period of 1 year form the date of purchase.

More information

DSO3062A Oscilloscope, 60 MHz

DSO3062A Oscilloscope, 60 MHz Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > 3000 Series portable economy oscilloscopes (4 models) > DSO3062A Oscilloscope, 60 MHz Product

More information

GFT6084 Quad 2 / 4GS Digitizer

GFT6084 Quad 2 / 4GS Digitizer FEATURES 2U, 19 Compact form factor 4 analog channels with vertical sensitivity 1mV/div to 10V/div Up to 2GS/s sampling rate per channel or 4 GS/s sampling rate on 2 channels DC to 500MHz Analog Bandwidth,

More information

DS2200C User Manual Copyright (c) EasySync Ltd. 2003

DS2200C User Manual Copyright (c) EasySync Ltd. 2003 DS2200C User Manual Copyright (c) EasySync Ltd. 2003 EasyScope User Manual All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical,

More information

WaveAce Series Oscilloscopes

WaveAce Series Oscilloscopes WaveAce Series Oscilloscopes 60 MHz 300 MHz Debug With Confidence THE TOOLS AND FEATURES FOR ALL YOUR DEBUG NEEDS Key Features 60 MHz, 100 MHz, 200 MHz and 300 MHz bandwidths Sample rates up to 2 GS/s

More information

Digital Storage Oscilloscope

Digital Storage Oscilloscope Digital Storage Oscilloscope GDS-3000 Series POWER ANALYSIS MANUAL GW INSTEK PART NO. 82DS-PWR00U01 ISO-9001 CERTIFIED MANUFACTURER April 2011 This manual contains proprietary information, which is protected

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Manual imso-204 Manual Table of Contents Section 1 Getting Started SAFETY 1.10

More information

Manual imso-204 imso-204l

Manual imso-204 imso-204l Manual imso-204 imso-204l Manual Table of Contents Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software 1.40 Tool Tips Section 2 How it works

More information

User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual

User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual 1 User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual 2 Certificate of Product Warranty This product s warranty, provided by our company, covers a period of 1 year form the date of purchase.

More information

DSO NANO v3 MANUAL.

DSO NANO v3 MANUAL. DSO NANO v3 MANUAL http://www.devicemart.co.kr Introduction DSO Nano v3 is a compatible 32bit digital storage oscilloscope. Based on ARM -M3, it s equipped with 320*240 color display, SD card, USB port

More information

USB Instruments EasyScope II for PS40M10 "Swordfish" Help

USB Instruments EasyScope II for PS40M10 Swordfish Help USB Instruments EasyScope II for PS40M10 "Swordfish" Help I EasyScope II for PS40M10 Help Table of Contents Part I Introduction 3 1 Welcome to... EasyScope II for PS40M10 3 2 EasyScope... II Features 4

More information

Velleman LEGEN HEIRWEG GAVERE BELGIUM. PCS64i PC Scope

Velleman LEGEN HEIRWEG GAVERE BELGIUM. PCS64i PC Scope Velleman LEGEN HEIRWEG 33 9890 GAVERE BELGIUM PCS64i PC Scope GENERAL The PCS64i is a digital storage oscilloscope whose display and operation uses an IBM compatible computer. All standard oscilloscope

More information

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

TBS2000 Oscilloscope Demo Guide 28 JULY 2016 TBS2000 Oscilloscope Demo Guide 28 JULY 2016 Table of Contents TBS2000 Series Oscilloscopes About This Guide & Required Equipment Setting up the Equipment Front Panel Tour Understanding the Display 1.

More information

LogicStudio Training Guide

LogicStudio Training Guide LogicStudio Training Guide Summary This guide provides step by step instructions explaining how to use the LogicStudio software. LogicStudio can operate in demo mode providing full access to all controls

More information

Compact 8 in 1 Multi-Instruments SF Series

Compact 8 in 1 Multi-Instruments SF Series Oscilloscope/ Spectrum Analyzer/ Data Recorder 1 GHz analog input bandwidth Automated Response Analyzer range: 1 Hz to 15 MHz Arbitrary Waveform Generator 1 mhz to 15 MHz output frequency Logic Analyzer

More information

Handyscope HS3. User manual. TiePie engineering

Handyscope HS3. User manual. TiePie engineering Handyscope HS3 User manual TiePie engineering ATTENTION! Measuring directly on the line voltage can be very dangerous. The outside of the BNC connectors at the Handyscope HS3 are connected with the ground

More information

The Next Generation of Portable Oscilloscope

The Next Generation of Portable Oscilloscope The Next Generation of Portable Oscilloscope GDS-1000 Series is a general purpose -channel oscilloscope and originally designed to meet educational and industrial requirements without specializing in DSO

More information

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation ECONseries BUS: USB Type: Economy, Mini-Instruments ECONseries Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost ECONseries modules are available to provide flexible yet economical

More information

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151 USER S MANUAL Contents 1. Main Features... 4 A Variety of Display Formats...4 Simple and Easy to Use...5 Thumbnail Waveform Display...5 Export to Direct Excel File Function...6 CSV File Batch Conversion...6

More information

PAD ANALOG / DIGITAL TRAINER OPERATOR S MANUAL

PAD ANALOG / DIGITAL TRAINER OPERATOR S MANUAL PAD - 234 ANALOG / DIGITAL TRAINER OPERATOR S MANUAL Rev. 7/94 GENERAL OPERATING PROCEDURES 1. This manual should be read thoroughly before engaging in any experimentation. 2. As a general rule, NEVER

More information

User s Guide. LA5034 Operation Manual

User s Guide. LA5034 Operation Manual User s Guide LA5034 Operation Manual Content General safety summary... I Introduction... II Chapter 1 Getting started... 1 System Requirements... 2 Installing Hardware... 3 Installing Software... 6 User

More information

VDS Series PC Oscilloscopes Quick Guide

VDS Series PC Oscilloscopes Quick Guide VDS Series PC Oscilloscopes Quick Guide WWW.OWON.COM Mar. 2015 edition V1.2.4 Copyright Lilliput Company. All rights reserved. The Lilliput's products are under the protection of the patent rights, including

More information

15. Check this point when you can t communicate

15. Check this point when you can t communicate * CONTENTS * 1. The organization of link system 2. FindView Installation 3. The FindView Software Main Screen 4. Communication Port setup 5. Scope Window 6. Meter Window 7. Notes Window 8. Menus and Toolbar

More information

RT USB3000 Technical Description and User Manual. Revision 4.1.

RT USB3000 Technical Description and User Manual. Revision 4.1. RT USB3000 Technical Description and User Manual. Revision 4.1. 1. GENERAL INFORMATION...2 2. SPECIFICATIONS...3 3. OPERATING MODES...7 3.1. ADC MODE...7 3.2. DAC MODE...7 3.3. LOGIC ANALYZER MODE...8

More information

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

Keysight U1602B and U1604B Handheld Digital Oscilloscopes Keysight U1602B and U1604B Handheld Digital Oscilloscopes Quick Start Guide Safety Information Use the product only as specified by the manufacturer. Do not install substitute parts or perform any unauthorized

More information

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup Lab 6 EasyScope Remote Control (30 Minutes) Note:(Screenshots below show a white background configuration of your WaveAce to save black ink in printing, this configuration is explained in Lab 2 VIEW) Overview

More information

The uscope Getting started

The uscope Getting started Introduction (fw 5.11) AES uscope Manual The uscope Getting started The uscope! A single channel, pocket-sized, digital storage oscilloscope that s small, quick, and powerful. Automotive presets get you

More information

MEphisto Scope 1 A D. Prozessor-Steuerung. Interner Daten-/Steuer-Bus. Digital I/O-Teil

MEphisto Scope 1 A D. Prozessor-Steuerung. Interner Daten-/Steuer-Bus. Digital I/O-Teil Block Diagram MEphisto Scope 1 V1.1 Kanal A A D * Werte- Speicher Kanal B A D (256 ks) Prozessor-Steuerung 26polige Sub-D Buchse Ext. Trigger 24 bits Digital I/O-Teil Interner Daten-/Steuer-Bus MEphisto

More information

for demos & updates

for demos & updates Check www.velleman.be for demos & updates MINIMUM SYSTEM REQUIREMENTS : IBM-compatible PC Windows 95, 98, ME (Win2000 / XP or NT possible) SVGA display card (min. 800x600 for Windows) mouse free printer

More information

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP sa Contents Description...3 System Requirements...3 Installing

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

CompuScope Ultra-fast waveform digitizer card for PCI bus.   APPLICATIONS. We offer the widest range of We offer the widest range of high-speed and high-resolution digitizers available on the market CompuScope 1602 Ultra-fast waveform digitizer card for PCI bus today. Our powerful PC-based instrumentation

More information

Dash HF Family High Speed Data Acquisition Recorder

Dash HF Family High Speed Data Acquisition Recorder Dash HF Family High Speed Data Acquisition Recorder QUICK START GUIDE (1) Introduction (2) Getting Started (3) Hardware Overview (4) Menus & Icons (5) Using the Dash HF (6) Setting Up the Display Appearance

More information

DATAMAN 570 series oscilloscope Rollmode User s Guide Version 2.02

DATAMAN 570 series oscilloscope Rollmode User s Guide Version 2.02 DATAMAN 570 series oscilloscope Rollmode Version 2.02 Copyright 2004-2009 Dataman Programmers Ltd For any further information or consultations, please contact us via phone or preferably e-mail on the following

More information

DIG-100M1002-PCI. Features. 100MSPS 2ch Digitizer Board for PCI DIG-100M1002-PCI 1. Ver.1.03

DIG-100M1002-PCI. Features. 100MSPS 2ch Digitizer Board for PCI DIG-100M1002-PCI 1. Ver.1.03 100MSPS 2ch Digitizer Board for PCI DIG-100M1002-PCI * s, color and design of the products are subject to change without notice. This product is a PCI-bus compliant digitizer board. It is designed with

More information

Front-Panel Menus and Controls

Front-Panel Menus and Controls Getting Acquainted with the Oscilloscope Front-Panel Menus and Controls The front panel has buttons and controls for the functions that you use most often. Use the menu buttons to access more specialized

More information

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6 Table of Contents Preface About this User's Guide... 5 What you will learn from this user's guide... 5 Conventions in this user's guide... 5 Where to find more information... 5 Chapter 1 Introducing the

More information

MotionDAS. MotionPro DAS User Manual (For Windows ) User Manual 1

MotionDAS. MotionPro DAS User Manual (For Windows ) User Manual 1 MotionPro DAS (For Windows ) 1 Software Release 1.05.01 Document Revision December 2017 Products Information http://www.idtvision.com North America 1202 E Park Ave TALLAHASSE FL 32301 United States of

More information

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC.

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC. AWG2300 USB Multifunction Arbitrary Waveform Generator Simultaneous dual channel waveform generation DC - 50 MHz output frequency range Waveform sampling rate: 300MS/s Waveform vertical resolution: 14-bit

More information

DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis

DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis ONO SOKKI CO., LTD. There are two types of tracking analysis, i.e., one is "constant ratio

More information

DLM2000 Series. Mixed Signal Oscilloscope. IM E 3rd Edition

DLM2000 Series. Mixed Signal Oscilloscope. IM E 3rd Edition DLM2000 Series Mixed Signal Oscilloscope 3rd Edition Thank you for purchasing the DLM2000 Series Mixed Signal Oscilloscope. This User s Manual explains how to use the DLM2000. To ensure correct use, please

More information

Compensation Range (pf.):

Compensation Range (pf.): Pomona s latest design of Passive Oscilloscope probes feature a one piece (monolithic) design for robust probe life. Probe bandwidth ratings are specified as a system bandwidth. System bandwidth includes

More information

This document contains the firmware release notes for two models. The SDS1202X-E is a dual channel 200 MHz scope.

This document contains the firmware release notes for two models. The SDS1202X-E is a dual channel 200 MHz scope. This document contains the firmware release notes for two models of SIGLENT SDS1000X-E oscilloscopes. The SDS1202X-E is a dual channel 200 MHz scope. The SDS1004X-E is a four channel scope available in

More information

Agilent Technologies 1680/90-Series Logic Analyzer. Service Guide. Publication number October 2005

Agilent Technologies 1680/90-Series Logic Analyzer. Service Guide. Publication number October 2005 Service Guide Publication number 01680-97016 October 2005 For Safety information, Warranties, and Regulatory information, see the pages at the end of the book. Copyright Agilent Technologies 2001, 2004-2005

More information

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

TETRIS 1000 / High Impedance Active Probe Order-No: Features: Features: High Impedance Active Probe Order-No: 881-000-000 881-500-000 High Input Impedance Interchangeable Spring Tips Contacts adjacent Pins in 2.54 mm Pitch Useable with any 50 Ω Measuring Instrument

More information

Compensation Range (pf.):

Compensation Range (pf.): Pomona s latest design of Passive Oscilloscope probes feature a one piece (monolithic) design for robust probe life. Probe bandwidth ratings are specified as a system bandwidth. System bandwidth includes

More information

DSO Nano Manual. v1.0b

DSO Nano Manual. v1.0b DSO Nano Manual v1.0b Intro DSO mobile is a pocket size digital storage oscilloscope fulfills basic electronic engineering requirements. It is base on ARM Cortex -M3 compatible 32 bit platform, equipped

More information

LGR-5325 Specifications

LGR-5325 Specifications s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are

More information

LGR-5327 Specifications

LGR-5327 Specifications s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are

More information

Quick Start Guide. January EAZ0081L02A Rev. A

Quick Start Guide. January EAZ0081L02A Rev. A Quick Start Guide January 2014 EAZ0081L02A Rev. A Trademarks Snap-on and Vantage Ultra are trademarks of Snap-on Incorporated. All other marks are trademarks or registered trademarks of their respective

More information

Sefram SEFRAM DAS 20/DAS 40. Sefram

Sefram SEFRAM DAS 20/DAS 40. Sefram Make sure to visit our Website http://www.sefram.fr Sefram Sefram SEFRAM DAS 20/DAS 40 2 to 4 analogue channels Universal input DC, AC+DC RMS voltage measurement Frequency, Thermocouple Power analysis

More information

1000 Series Portable Oscilloscopes

1000 Series Portable Oscilloscopes 1000 Series Portable Oscilloscopes Data Sheet Engineered to give you more scope than you thought you could afford More scope than you thought you could afford Agilent s new 1000 Series oscilloscopes deliver

More information

Multi VirAnalyzer MDSO-LA

Multi VirAnalyzer MDSO-LA Multi VirAnalyzer MDSO-LA Model User Guide 2011-11-1 1 contents 1.Introduction 1 2.Feature Description 2 3.Software Installation 2 3. 1 I n s t a l l a t i o n p a c k a g e 2 3.2 Hardware connection 2

More information

Analog Input Sample Rate

Analog Input Sample Rate ECONseries Low Cost USB Data Acquisition Modules Overview The ECONseries is a flexible yet economical series of multifunction DAQ modules. You chse the number of analog I/O and digital I/O channels, the

More information

USB-1616FS. Analog Input and Digital I/O. Specifications

USB-1616FS. Analog Input and Digital I/O. Specifications Analog Input and Digital I/O Specifications Document Revision 1.6 May 2012 Copyright 2012 Specifications All specifications are subject to change without notice. Typical for 25 C unless otherwise specified.

More information

ECONseries Low Cost USB DAQ

ECONseries Low Cost USB DAQ ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog

More information

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A... Electronics & Software DynoWare Software for Data Acquisition and Evaluation 2825A... Kistler DynoWare is a universal and easy to use software, which is particularly suitable for force measurements with

More information

Specifications USB-1616FS

Specifications USB-1616FS Document Revision 1.5, July, 2006 Copyright 2006, Measurement Computing Corporation Typical for 25 C unless otherwise specified. in italic text are guaranteed by design. Analog input A/D converters Number

More information

A variety of ECONseries modules provide economical yet flexible solutions

A variety of ECONseries modules provide economical yet flexible solutions Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost modules are available to provide flexible yet economical solutions. Choose the number of analog I/O and digital I/O channels,

More information

DP MHz 2GS/s. PCI Digitizer Card with Oscilloscope Characteristics

DP MHz 2GS/s. PCI Digitizer Card with Oscilloscope Characteristics 500 MHz 2GS/s PCI Digitizer Card with Oscilloscope Characteristics Main Features 2 GS/s Sampling Rate 500 MHz Bandwidth 256 kpoints Acquisition Memory (4 Mpoints optional) Full Front-end Amplification

More information

USB-201-OEM. Analog and Digital I/O. User's Guide

USB-201-OEM. Analog and Digital I/O. User's Guide USB-201-OEM Analog and Digital I/O User's Guide Document Revision 7A December 2014 Copyright 2014 Trademark and Copyright Information Measurement Computing Corporation, InstaCal, Universal Library, and

More information

TFX PC Power Specifications

TFX PC Power Specifications TFX PC Power Specifications Model: HK340-71FP Consumer:Huntkey File NO: 试 产 Prepared by: Rex Checked by: Zhi Wu Approved by: Zhi Wu Issue date: 2010-03-29 REV:02 Model:HK340-71FP P/N:P15-3407100R Page

More information

Specifications USB-1408FS

Specifications USB-1408FS Document Revision 1.1, May, 2006 Copyright 2006, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input Table

More information

USB-1602HS-2AO Specifications

USB-1602HS-2AO Specifications s Revision 1.0, March, 2009 Copyright 2009, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. All signal names refer

More information

PC Software R&S FS300-K1

PC Software R&S FS300-K1 Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1350 HIGH TEMP ADC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1350 HIGH TEMP ADC LTC2246H, LTC2226H DESCRIPTION Demonstration circuit 1350 supports a family of 12 and 14-Bit 25Msps ADC. This assembly features one of the following devices: LTC2226H or LTC2246H high speed, high dynamic

More information

CANScope. CANScope Analyzer

CANScope. CANScope Analyzer User Manual Analyzer UM12090301 V1.01 User Manual Item Terms Abstract ontents, safety on usage, hardware description, P software, parameters This document is an overview on how to use the analyzer. www.zlg.cn

More information

MOTOR ARMATURE TESTER

MOTOR ARMATURE TESTER MOTOR ARMATURE TESTER 6920 ENGLISH MANUAL 1 st Oct 2008 CATALOG BEFORE USE...1 1.1 Product Introduction...1 1.2 Product Characteristic...1 2 SPEC INSTRUCTION...2 3 SAFETY INSTRUCTION...4 4 INSTALLATION...6

More information

DL7200 Digital Oscilloscope CAN Bus Signal Analysis Function

DL7200 Digital Oscilloscope CAN Bus Signal Analysis Function User s Manual DL7200 Digital Oscilloscope CAN Bus Signal Analysis Function IM 701430-51E Yokogawa Electric Corporation IM 701430-51E 2nd Edition Thank you for purchasing the DL7200 Digital Oscilloscope

More information

2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

2019 RIGOL (SUZHOU) TECHNOLOGIES INC. Quick Guide 中文 MSO5000 Series Digital Oscilloscope Feb. 2019 (SUZHOU) TECHNOLOGIES INC. Guaranty and Declaration Copyright 2018 (SUZHOU) TECHNOLOGIES INC. All Rights Reserved. Trademark Information is

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols... 2 3. Quick Start...

More information

Handheld Digital Storage Oscilloscope with DMM

Handheld Digital Storage Oscilloscope with DMM Handheld Digital Storage Oscilloscope with DMM GDS-200 and GDS-300 Series USER MANUAL ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All

More information

USB-1208LS Specifications

USB-1208LS Specifications Specifications Document Revision 1.1, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.

More information

Specifications PMD-1208FS

Specifications PMD-1208FS Document Revision 1.1, May, 2005 Copyright 2005, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input section

More information

Infiniium X / L- Series Oscilloscopes

Infiniium X / L- Series Oscilloscopes Service Guide Publication Number 54916-97009 October 2013 Agilent Technologies, Inc. 2011-2013 Infiniium 90000 X / L- Series Oscilloscopes Agilent Infiniium 90000 X-Series Oscilloscopes at a Glance Ease

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

MicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test

MicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test Providing tools for Embedded Engineers Digital Designers MicroBench MB-500A a complete digital tool set Technical Data Five test tools in one compact, affordable instrument: Live Logic Logic source pattern

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

Model P4025T. 200MHz Digital Storage Oscilloscope. With Touchscreen. Quick-Start Guide

Model P4025T. 200MHz Digital Storage Oscilloscope. With Touchscreen. Quick-Start Guide Model P4025T 200MHz Digital Storage Oscilloscope With Touchscreen Quick-Start Guide Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols... 2 3. Quick Start... 4 Introduction

More information

ECONseries Low Cost USB DAQ

ECONseries Low Cost USB DAQ ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog

More information

Service Guide. Publication Number March Agilent Technologies, Inc Infiniium A-Series Oscilloscopes

Service Guide. Publication Number March Agilent Technologies, Inc Infiniium A-Series Oscilloscopes Service Guide Publication Number 54913-97022 March 2013 Agilent Technologies, Inc. 2007-2013 Infiniium 90000 A-Series Oscilloscopes Agilent Infiniium 90000 A-Series Oscilloscopes at a Glance Ease of use

More information

14 Bit rsp. 16 Bit. 80 MS/s 40 MS/s 20 MS/s 10 MS/s

14 Bit rsp. 16 Bit. 80 MS/s 40 MS/s 20 MS/s 10 MS/s Module Type 14bit A/D TPCX/E-8014-4 TPCX/E-4014-4 TPCX/E-2014-4/8 TPCX/E-1014-4/8 Module Type 16bit A/D TPCX/E-8016-4 TPCX/E-4016-4 TPCX/E-2016-4/8 TPCX/E-1016-4/8 *1 Number of Input Channels Amplitude

More information

The uscope Getting started

The uscope Getting started Introduction (fw 6.01) The uscope Getting started The uscope! A single channel, pocket-sized, digital storage oscilloscope that s small, quick, and powerful. Automotive presets get you going quickly. Ideal

More information

OX 5022-CK OX 5042-CK

OX 5022-CK OX 5042-CK QUICK START USER GUIDE OX 5022-CK OX 5042-CK Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

EasyScopeIII for DS60M10. User Guide

EasyScopeIII for DS60M10. User Guide EasySync Ltd EasyScopeIII for DS60M10 User Guide Document Reference No.: ES_000095 Issue Date: 2012-11-19 EasySync Ltd Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom

More information

Infiniium Q- Series Oscilloscopes

Infiniium Q- Series Oscilloscopes Service Guide Publication Number 54932-97006 October 2013 Agilent Technologies, Inc. 2012-2013 Infiniium 90000 Q- Series Oscilloscopes The Agilent Technologies Infiniium 90000 Oscilloscope at a Glance

More information

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use.

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use. DATA PLATFORM GL7000 Quick Start Guide GL7000-UM-852 Thank you very much for buying the DATA PLATFORM GL7000. This quick manual provides easy to understand instructions for the basic operations. For detailed

More information

Logic Analyzer Software Manual

Logic Analyzer Software Manual Logic Analyzer Software Manual Link Instruments, inc. 17A Daniel Road East Fairfield, NJ 07004 Phone: 973-808-8990 Fax: 973-808-8786 Web: www.linkinstruments.com Email: sales@linkinstruments.com I Logic

More information

EECS 211 CAD Tutorial. 1. Introduction

EECS 211 CAD Tutorial. 1. Introduction EECS 211 CAD Tutorial 1. Introduction This tutorial has been devised to run through all the steps involved in the design and simulation of an audio tone control amplifier using the Mentor Graphics CAD

More information

LDR_Light_Switch1 -- Overview

LDR_Light_Switch1 -- Overview LDR_Light_Switch1 -- Overview OBJECTIVES After performing this lab exercise, learner will be able to: Understand the functionality of Light Dependent Resistor (LDR) Use LDR (Light Dependent Resistor) to

More information

DS1000B Series Digital Oscilloscope

DS1000B Series Digital Oscilloscope Quick Guide RIGOL Publication number QGA04114-1110 Feb. 2014 DS1000B Series Digital Oscilloscope DS1074B, DS1104B, DS1204B All Rights Reserved Copyright All Rights Reserved. RIGOL products are protected

More information

Training Kit for HP 1660/70 Series Logic Analyzers

Training Kit for HP 1660/70 Series Logic Analyzers Training Guide Publication Number E2433-97034 First Edition, November 1997 For Safety information, Warranties, and Regulatory information, see the pages behind the Index. Copyright Hewlett-Packard Company

More information

Specifications USB-1616HS

Specifications USB-1616HS Document Revision 1.0, August, 2007 Copyright 2007, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input A/D

More information

Section 1 Establishing an Instrument Connection

Section 1 Establishing an Instrument Connection Manual for Sweep VI Fall 2011 DO NOT FORGET TO SAVE YOUR DATA TO A NEW LOCATION, OTHER THAN THE TEMP FOLDER ON YOUR LAB STATION COMPUTER! FAILURE TO DO SO WILL RESULT IN LOST DATA WHEN YOU LOG OUT! 1.1.