Reference Guide METTLER TOLEDO WMH Weighing Platforms
|
|
- Drusilla Fitzgerald
- 5 years ago
- Views:
Transcription
1 Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, C
2 Weighing Platforms Reference Guide Contents 1 Initial Setup Installation Electrical Connection Connecting to a PC Quick Configuration Guide Documentation Overview File Structure of the CD-ROM Where to Find What Technical Data General Data Technical Specifications
3 Reference Guide Weighing Platforms 1 Initial Setup 1.1 Installation Selecting the installation location The foundation of the installation location must be capable of safely supporting the weight of the weighing platform at its support points when it carries the maximum load. The foundation must also be so stable that no vibrations occur during weighing operations. These requirements also apply when the weighing platform is integrated in conveying systems and the like. Ensure that vibrations due to machines near the installation site are kept to a minimum. Setting up and leveling Remove the weighing platform from the packaging. Place the load plate on the weighing platform. Level the weighing platform with the 4 leveling screws (1) using the level indicator (2). The air bubble of the level indicator must come to rest within the ring marking. Ensure even contact of the leveling screws. Check the stability of the weighing platform by pressing down on, or rocking it, at the corners. Lock the leveling screws with the nuts. Releasing the transportation lock for high-capacity platforms, see Documents_K-Line > K-Line_installation_information_...pdf. Installing the connection cable Connection cables up to 10 meters long are available as accessories. Route the connection cable so that it is protected from possible damage. 4
4 Weighing Platforms Reference Guide 1.2 Electrical Connection METTLER TOLEDO recommend connecting weighing platforms by means of the METTLER TOLEDO ConModule or the ConBox and the corresponding cables (available as accessories). The ConModule is mandatory if digital inputs or outputs are used. If neither of the above connection modules are used, the power supply must fulfill the requirements of EN :2000 and must incorporate a fuse of 750 ma. Pin assignments of the 19-pin plug, Binder type, series 423, viewed from the solder side of the female cable plug: RS232 RS422 Pin Wire color Code Interface Remarks ConModule Terminal No. - Shielding Shield Shield 20 PIN A Grey-pink VSS (10..28VDC) Plus pole of supply voltage 11 PIN B Purple DGND RS232 Ground potential for RS PIN C Black Rx- (*Rx) RS422 Receiving wires RS PIN D Red DIN1 Digital input 1 8 PIN E Blue Factory Leave wire open 7 PIN F Pink DOT 1 Digital output 1 6 PIN G Grey Factory Leave wire open 5 PIN H Yellow DIN 0 Digital input 0 4 PIN J Green DIN 2 Digital input 2 3 PIN K Brown DOT 0 Digital output 0 2 PIN L White Tx+ (Tx) RS422 Transmission wires RS PIN M Red-blue TxD RS232 Transmission wire RS PIN N White-pink RxD RS232 Receiving wire RS PIN O Grey-brown GND (to VSS) Minus pole of supply voltage 18 PIN P White-grey Tx- (*Tx) RS422 Transmission wires RS PIN R Yellow-brown CTS RS232 Data flow control RS PIN S White-yellow RTS RS232 Data flow control RS PIN T Brown-green DOT 2 Digital output 2 14 PIN U White-green Rx+ (Rx) RS422 Receiving wires RS The wire color refers to the WM connection cables which are available as accessories. 5
5 Reference Guide Weighing Platforms 1.3 Connecting to a PC Connect your weighing platform to the RS232 port of a PC according to section 1.2. Connect the platform to a suitable power source. To configure the platform, it is advisable to use its RS232 interface. If the ConModule or the ConBox is part of your configuration, use its Dsub9 service plug to connect it to a standard RS232 cable. Install the Windows WM Term Disp Software (CD-ROM > English > Software > WM_Terminal_Display) on your computer by double-clicking the Setup.exe file. Start the WM Term Disp. program. Click the Configure button to configure the COM port of your computer to the factory settings of the weighing platform: 9600 baud, 8 bits, no parity, 1 stop bit, no handshake. (Detailed information about the interface configuration parameters of your weighing platform can be found in the enclosed Reference Manual (MT-SICS) under the COM command.) Activate the display by clicking the Display button. If the connection has been correctly made, you will now see the actual weight value in the display of the WM Term Disp program. Click the buttons SI, S, T, Z to send the most frequently used commands to the weighing platform. A detailed description of how to use the WM Term Disp program can be found in CD-ROM > English > Software > WM_Terminal_Display > WM_term_disp_HELP.pdf. To display a graph of the weight values against time on your PC, you can also use the WM Graph Disp. program. Please follow the instructions in the Read Me file of the CD-ROM > English > Software > WM_Graphical_Display for installation. It is necessary to run both Setup.exe files. Follow the instructions in the next section to configure your weighing platform. Please also browse through Section 2.2 which tells you how to find detailed information about selected topics that will optimize the use of your weighing platform. 6
6 Weighing Platforms Reference Guide 1.4 Quick Configuration Guide A number of adjustable parameters allow the weighing platform to be configured to customer-specific needs. To achieve optimum results for repeatability and speed, some parameters must be changed from the factory settings to a configuration that best suits your individual application. The list below shows the 10 most important parameters which need to be verified and adjusted and the respective commands which must be executed. Please refer to the respective command in the enclosed Reference Manual (MT-SICS) and adjust the parameters to the appropriate values. Please see also the EN051_nn_Process-Specific- Configuration.pdf for tips and examples about individual configuration of weighing platforms. # Subject Command Remarks / Example 1 Configuration of the interface parameters (RS232 and RS422) 2 Adjustment (calibration) of the weighing platform 3 Setting the weighing mode: weight control, dispensing, user defined COM Factory setting 9600 baud, 8-N-1, no HS COM COM C3, C2 It is recommended to adjust the weighing platform at its place of installation using either the internal or a suitable external weight during initial commissioning and at regular intervals thereafter. M01 M01 0 Weight control (factory default setting) M01 1 Dispensing 4 Setting of weight signal filter M02 M02 0 Lowest attenuation fast results M02 2 Medium attenuation M02 4 Highest attenuation, for very demanding environmental conditions 5 Setting of stability criteria for weighing, taring, and zero setting M30 The settings of "M30" affect the stabilization time as well as the repeatability of the weight measurement. Format: M30 Funct Tol Time Better repeatability is obtained by: - decreasing Tol (number of digits); - increasing time (seconds). Example: M Setting the readability RDB Smallest weight increment = 1 digit 7 Setting the update rate (output data rate) UPD Permissible values are 1 to 7, 9, 12, 19, and 38 updates per second. The default factory setting is 9. Please note the correct setting of the baud rate > COM 8 Setting the output format (control mode) MOD Allows the output format of weighing platforms to be extended by an auxiliary numerical increment. 9 List all current user settings LST Lists all current settings that can be changed by the user. 10 Reset all settings to factory defaults FSET All factory defaults are listed in Manuals > MT- SICS_for_WM_ doc, Appendix
7 Reference Guide Weighing Platforms 2 Documentation Overview 2.1 File Structure of the CD-ROM 8
8 Weighing Platforms Reference Guide 2.2 Where to Find What # Subject Reference Document 1 Setting up, leveling, and releasing the transport lock for high-capacity platforms Documents_K-Line > K-Line_installation_information_...pdf 2 Dimensions of weighing platforms Documents_K-Line > K-Line_installation_information_...pdf 3 Planning of assemblies: Recommended and maximum preload, preload range. Note: The maximum preloads of and K-Line platforms are different. 4 Planning assemblies: mounting possibilities Engineering_Notes > EN081_nn_Preloads_and_Adjustment.doc Documents_K-Line > K-Line_installation_information_...pdf 5 Installing high-capacity weighing platforms Documents_K-Line > K-Line_installation_information_...pdf 6 Detailed user manual for weighing platforms Manuals > -Manual_e_ pdf 9
9 Reference Guide Weighing Platforms 7 Detailed descriptions of all interface commands and adjustment parameters Document included in delivery or Manuals > MT- SICS_for_WM_ doc 8 Optimum configuration of adjustable parameters process-specific configuration EN051_nn_Process-Specific- Configuration.pdf 9 Fast weighing of very small weights using the trigger mode EN041_nn_Trigger-Mode.pdf 10 Use of digital inputs Weighing substance Photocell gate Control system (e.g. SPS) RS232 / RS422 EN041_nn_Trigger-Mode.pdf Weighing module ConModule RS232 / RS Use of digital outputs for checkweighing, plus/minus weighing, weight control EN071_nn_Weight_Monitoring.pdf 12 Use of digital outputs for dispensing EN071_nn_Weight_Monitoring.pdf 10
10 Weighing Platforms Reference Guide 13 System start after power failure; maximization of process safety EN061_nn_PowerFail-Restart.pdf EN011_nn_Process-Safety.pdf 14 Mechanical accessories: stands, roller tracks, etc. Documents_K-Line > K-Line_operating_instruction_...pdf 15 Electrical accessories: connection modules, Profibus and DeviceNet modules Manuals > -Manual_e_ pdf Chapter 8 16 Cleaning Documents_K-Line > K-Line_operating_instruction_...pdf 17 Spare parts, maintenance, repairs Please contact the METTLER TOLEDO service organization Repair Form 11
11 Reference Guide Weighing Platforms 3 Technical Data 3.1 General Data Power supply voltage Power requirement at 24 VDC (typical) While operating During calibration/test with built-in weight (approx. 5 sec.) When switching on (approx. 0.1 sec.) Electrical connection Recommended conductor cross-section for power supply wires Recommended conductor cross-section for data wires Interfaces RS-232, bi-directional, full duplex RS-422, bi-directional, full duplex, can be used on bus (120 ohms termination) IP protection level Permissible environmental conditions Temperature range Altitude above MSL 1) Relative humidity (at 30 C / 85 F) Housing material 10 VDC VDC 2.5 W 4 W 20 W 19-pin male, Binder type, series mm 2 (AWG 24) 0.14 mm 2 (AWG 26) baud 7 or 8 bits Parity: even, odd, or none 1 or 2 stop bits Handshake parameters are ignored IP67, IP66 5 C C / 40 F F Max. 4,000 m / 13,330 ft Max. 85 % Chrome-nickel steel DIN X5 CrNi1810 1) When used at altitudes greater than 2,000 m above msl, the power supply unit for the weighing platform must fulfill the standard which is applicable for this altitude. 12
12 Weighing Platforms Reference Guide 3.2 Technical Specifications A15 A32 B60 CC150 CC300 CS300 CS600 C300 C600 D600 D1500 E1500 E3000 ES1500 ES3000 Maximum load 1) [kg] Readability Reproducibility (s) 2) [g] Linearity, typical (temperature range C) Dimensions of weighing platform * = weighing cell W D Hmin-Hmax [g] [g±] 0.2 [mm] Max. recommended preload 3) [kg] 4 Preload range 4) [kg] *) Zero-setting range [kg] open External weight or preload when calibrating/testing with external weight (C2) Minimum external weight [kg] Maximum preload [kg] Maximum preload 5) when calibrating/testing with built-in weight (C3) External weight 6) or preload for comparison of the internal calibr. factor (C4) Minimum external weight [kg] Maximum preload [kg] Temperature range According to accuracy class II According to accuracy class III [ C] ) Effective maximum load, depending on the preload. If this load is exceeded, the weighing platform responds with S+, Z+, or T+. 2) Corresponds to the standard deviation of 10 consecutive measurements with factory settings and under normal environmental conditions. 3) Max. recommended preload. After the preload has been put in place, no adjustment by the customer is necessary. 4) Preload range. These preloads can be added without reducing the nominal maximum capacity. 5) Calibration/test with high (pre)load with built-in weight not possible. 6) Sum of weights used plus preload is less than the maximum load. 13
13 For the future benefit of your METTLER TOLEDO product, and to preserve its value, METTLER TOLEDO service assures its quality and measuring accuracy for years to come. Please request full details of our attractive terms of service. Thank you. Subject to technical changes. Printed on 100 % chlorine-free paper. For the sake of our environment. Mettler-Toledo GmbH 2005 Doc.Nr. KA021, C Printed in Switzerland, February Mettler-Toledo GmbH, CH-8606 Greifensee, Switzerland Internet:
Installation Manual. WKC Weigh Modules
Installation Manual Weigh Modules Table of Contents 1 Installation 3 1.1 Mechanical installation... 3 1.1.1 Support Interface (Support Surface)... 3 1.1.2 Weighing Interface (Weighing Platform)... 3 1.2
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationAssembly Instructions scancontrol 2700/2750 (500)
Assembly Instructions scancontrol 2700/2750 (500) 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply
More informationOperating instructions METTLER TOLEDO BD balances
Operating instructions METTLER TOLEDO BD balances 0.00 g Startup procedure 1 Unpacking, standard equipment The standard equipment contains: BD balance, Weighing pan, permanently mounted with BD6000, AC
More informationAutomated Precision Weighing
Automated Precision Weighing Smart Load-Cell Technology The load cell, with Monobloc technology, is at the core of the SLF6-Series load cells and guarantees the highest precision and reliability. A robust
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationProduct Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4
USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4 2 USBG-BAY4 Product Manual Revision History Revision Date Author
More informationSartorius Comparator. Interface Description for the CC Model Series
98647-000-53 Sartorius Comparator Interface Description for the CC Model Series Contents Page General Information 4 General Specifications 5 Data Output Formats 6 Data Input Formats 11 Synchronization
More informationAddendum for 125B Bushealth Measurements
Addendum for 125B Bushealth Measurements Introduction This Addendum contains information to extend the information presented in the Fluke 125B Users Manual. The purpose of this Addendum is to give more
More informationTRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4
TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationIT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to
IT 1910i Industrial 2D-code hand-held scanner EN 50123791 2013/06 We reserve the right to make technical changes TECHNICAL DESCRIPTION 2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen /
More informationProduct description Rev. 3 11/06/14
EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationTechnical data. Your advantages
Technical data Nominal torque: 10.000 Nm to 25.000 Nm, bidirectional Customer-specific calibration upon request Rotational speed: 8.000 rpm Accuracy: ±0,5 % Temperature range: -30 C to +85 C Protection
More informationUser Manual. Printer P-52RUE
User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4
More informationEX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)
EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an
More informationManual Fiber Optic Interfaces
Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it
More informationCMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual
CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,
More informationMGate 4101-MB-PBS Series
MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII
More informationThe sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.
Assembly Instructions scancontrol 2600/2650/2900/2950 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply
More informationOperating Instructions. Modules Fieldbus
Operating Instructions Modules Fieldbus Leer Table of Content 1 Introduction... 5 1.1 General... 5 1.2 Compatibility... 6 1.3 Related Documentation... 6 1.4 Internet addresses... 6 2 Functional Overview...
More informationVirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual
VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...
More informationADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual
ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following
More informationManual Industry Interfaces
Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should
More informationCharacteristics and functioning
Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationX-Series System Manual Part 7: Interfaces and data communication
X-Series System Manual Part 7: Interfaces and data communication Version check: Version No. Date Version 3.1 April 2012 Version 3.0 April 2011 Version 2.0 October 2007 Version 1.0 March 2006 Mettler-Toledo
More informationInstallation Guide Controller Series E130/E230/E430
Controller Series E0/0/0 Installation Guide Controller Series E0/E0/E0 Products E0-DP E0-DP E0-DP Content IMPORTANT NOTES FOR E0/E0/E0 SERIES CONTROLLERS... SYSTEM OVERVIEW... E0 SERIES FUNCTION AND WIRING...
More information4.7 Expansion Module MAC00-FS1/FS4
MAC00-FS4 With M12 connectors MAC00-FS1 With D sub connectors TT1068GB 4.7.1 High speed serial RS485 module MAC00-FS1 and FS4 Introduction The MAC00-FS1 and FS4 are used for high speed RS485 communication
More informationManual DTM Digital Pressure Transmitter
TetraTec Instruments GmbH Gewerbestr. 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 Manual Digital Pressure Transmitter *** VERSION 1.1 *** Update: 22.11.2006
More informationPOSICHRON PCQA Mounting Sets
PCQA Mounting Sets Mounting set PCQA-BFS1 with mounting clamps Isolation sleeve 46 Isolation strip Mounting clamp P 58 Option -BFW Mounting brackets for PCQA22 and PCQA24 Note: The option -BFW can only
More informationInclinometer. 4-20mA and RS232
Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation
More informationInstallation Manual. Weigh Modules WMS/WMS Ex Zone 2
Installation Manual WMS/WMS Ex Zone 2 Table of Contents 1 Commissioning 3 1.1 Overview... 3 1.2 Assembling before commissioning... 4 1.2.1 Labyrinth ring... 4 1.2.2 Attaching the weighing platform...
More informationSerial PROFIBUS Interface
Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationPCI Express 4-Port Industrial Serial I/O Cards
PCI Express 4-Port Industrial Serial I/O Cards The PCIe-400i and PCIe-400i-SI PCI Express 4-port industrial serial I/O cards are plug & play high-speed serial I/O expansion cards for the PCI Express bus.
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationSartorius Research. R 160 P Electronic Semi-Microbalance
Sartorius Research. R 160 P Electronic Semi-Microbalance Installation and Operating Instructions 1 Power receptacle, fuse, 8 Level indicator voltage selector 9 ON/OFF key 2 Menu access switch 10 Print
More informationFIT 7A. Digital load cell dynamic weighing. Special features. Data sheet
FIT 7A Digital load cell dynamic weighing Special features - Accuracy class up to C4 and maximum scale interval factor Y up to 25,000 with OIML R60 test report - Off-center load compensated (OIML R76)
More informationIQ SENSOR NET MIQ/IF232
Operating Manual IQ SENSOR NET Power! OK RS232 interface module for the IQ SENSOR NET ba76037e01 01/2012 Note For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI
More informationS SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default
More informationTechnical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0
Technical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0 The sensor series SONOFLOW CO.55/xxxSD V2.0 with stainless steel housing and display designed as clamp-on-sensors detect the flow rate of liquids in plastic
More informationUSB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual
USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationUser Manual CTP64-Rotate
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP64-Rotate 64 channel
More informationCharacteristics and functioning
Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...
More information4.8 Expansion Module MAC00-FS1/FS4
.8 Expansion Module MAC00-FS/FS MAC00-FS With M connectors MAC00-FS With D sub connectors TT08GB.8. High speed serial RS8 module MAC00-FS and FS Introduction The MAC00-FS and FS are used for high speed
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...
E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationThe modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface
DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,
More informationPCD DIGITAL Differential pressure probe
Differential pressure probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information... 6 3.1 Power supply...
More informationioselect Z-NET Z-SG Bridge Input Isolating I/O Module
-wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:
More informationNote: the wiring of the dead-man buttons has been changed since October 2001.
UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making
More informationRHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter
RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x A 1 INTRODUCTION The RHT-WM-485-LCD and RHT-DM-485-LCD transmitters include high
More informationMIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2
1 MIST Version 2.0 USER S GUIDE Preliminary Version INTRODUCTION...2 General Description...2 Models Available...2 INSTALLATION...2 Unpacking...2 Mechanical Installation...3 Electrical Wiring...3 Stand-alone
More informationInstallation Instructions for: Channel Thermocouple Amplifier
Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier The Advanced Engine Management (AEM) 4 channel thermocouple amplifier revolutionizes temperature measurements by providing laboratory
More informationGetting started with your DGH module:
Getting started with your DGH module: This document contains step-by-step instructions to quickly connect and communicate with your new DGH modules. For most applications, new modules require a one-time
More informationSERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS
HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according
More informationW&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration
Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,
More informationSCB-C08 USB to RS232/422/485 Converter
SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with
More informationUSB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual
USB to RS-232/RS422/485 URK-228-I USB To Serial Operation Manual First Edition, Feb 2012 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description
More informationBNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide
BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical
More informationFeatures and Benefits. Certifications
NPort IA5000 Series 1 and 2-port serial device servers for industrial automation Features and Benefits Socket modes: TCP server, TCP client, UDP Patented ADDC (Automatic Data Direction Control) for 2-wire
More informationMoxa TCC-100 Series User s Guide
Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The
More informationFeatures. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter
The is an interface box for connecting a PC, data logger or telemetry unit to one or more sensors with SDI-12 interface. The connects to a data logger, telemetry unit or other device with RS485 interface
More information1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications
UPort 1000 Series 1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters Features and Benefits Hi-Speed USB 2.0 for up to 480 Mbps USB data transmission rates 921.6 kbps maximum baudrate
More informationOperating Instructions. Modules Fieldbus
Operating Instructions Modules Fieldbus Leer Table of Content 1 Introduction... 6 1.1 General... 6 1.2 Compatibility... 7 1.3 Related documentation... 7 1.4 Internet addresses... 7 2 Functional Overview...
More informationTRP-C06H User s Manual
TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationChannel Switch CS. General Operating, Maintenance and Installation Manual
Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September
More informationUSB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.
USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...
More informationOPERATION MANUAL. REDOX Measurement Unit. LAMBDA REDOX Red-Ox Potential measurement unit
OPERATION MANUAL REDOX Measurement Unit LAMBDA REDOX Red-Ox Potential measurement unit LAMBDA REDOX measurement unit LAMBDA REDOX allows the measurement of the Red-Ox potential (ORP) and the digital transfer
More informationOperating Instructions
Operating Instructions METTLER TOLEDO FlowPac-M MAX I D 7 Date 8 Time 9 Reset +5% MIN Co de 4 Prt % 5 6 Clear -5% 0 Mo de Preset Tol % 2 3 Print STOP M-TARE ++ /- 0 FILL. - ENTER Leerseite Contents. Preparation
More informationMEC-COM-M134. User s Manual
MEC-COM-M134 Mini PCI-e 4-port RS-232/422/485 serial board with power input User s Manual Third Edition, February 2014 Mini PCI-e Serial Card User s Manual 2 Table of Contents Chapter 1 Introduction 4
More informationUSER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION
USER S MANUAL SI-700 SI-700 - EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 TM FOUNDATION S I 7 0 0 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
More informationPCI Express 16-Port Serial I/O Cards
PCI Express 16-Port Serial I/O Cards The PCIe-1600 PCI Express 16-port serial I/O card is a plug & play high-speed serial I/O expansion card for PCI Express bus. Connecting to a PCI Express bus on your
More informationIPC194. ipconv Protocol Converter
IPC194 General Operating, Maintenance and Installation Manual ipconv Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de Email: info@ipcomm.de
More informationF3EM Measuring lightcurtain in robust aluminium housing
Measuring lightcurtain in robust aluminium housing F3EM Measuring lightcurtain in robust aluminium housing The F3EM provides easy to install and set up height and profile measurement. The analog output
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationGeneral Operating, Maintenance and Installation Manual
General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:
More informationMGate 5105-MB-EIP Series
MGate 5105-MB-EIP Series 1-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways Features and Benefits Protocol conversion between Modbus and EtherNet/IP Supports EtherNet/IP Scanner/Adapter Supports Modbus
More informationPCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T
PCIe Card Selection Guide PCIe-CAN Card Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T Channels I/O Isolation Voltage Baud Rate Terminator Resistor I/O PIN Type 2 Max. 1 Mbps Jumper for 120
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationMU110-6U. Analog output module 6 channel. User guide
MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)
More informationMotortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision
Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803
More informationEngineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O
Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process
More informationUSB-COM Plus ISO (USB-COMi SI-M)
VS Vision Systems GmbH / Part Number 603 Features 1 x RS232/422/485 port USB 2.0 Full Speed interface 2.5kV isolation per serial port USB and serial ports ESD protected Robust metal case Jumperless, DIP
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories
2D-code hand-held scanner Dimensioned drawing 4-14 V DC We reserve the right to make changes BP_IT4600_4800_GB.fm Part No. 501 06667! Hand-held scanner for Data-Matrix Codes and Bar Codes! Large reading
More informationDigital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.
Digital Bench Scale Revision 1.2 September 14, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702
More informationTransmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD
Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters
More informationArm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications
IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk
More informationCONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual
5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationInstallation Manual. SLP85xD Load cells
Installation Manual SLP85xD Load cells Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use of your new equipment according to this Manual and regular calibration and maintenance
More information3.1 I-7560 Pin Assignment and Specifications: Introduction
3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows
More informationOperation Manual Profibus DP -Display HE 5120 P with digital I/O's
Operation Manual Profibus DP -Display HE 510 P with digital I/O's "HESCH" Schröder GmbH Boschstraße 8 31535 Neustadt Telefon +49 (0) 503 / 9535-0 Telefax +49 (0) 503 / 9535-99 e-mail: info@hesch.de http://www.hesch.de
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationOFP401P0189. Color Sensor. Operating Instructions
OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection
More information