Planning and Sizing Virtualization. Jaqui Lynch Architect, Systems Engineer Mainline Information Systems

Size: px
Start display at page:

Download "Planning and Sizing Virtualization. Jaqui Lynch Architect, Systems Engineer Mainline Information Systems"

Transcription

1 Planning and Sizing Virtualization Jaqui Lynch Architect, Systems Engineer Mainline Information Systems 1 What is a CPU Chips are dual or quad core But in IBMese cpus = way = cores = processors 1 cpu = 1 way = 1 core = 1 processor So a 3 way is 3 processoors or cores Regardless of how many sockets Vendors tend to license by cores/cpus 1

2 What is Virtualization? Being able to dynamically move resources Being able to share resources Making better use of the resources Driving utilization up Etc etc etc Some think it is 4 3 Reasons to Partition Consolidation Hosting Production and Test on same hardware Multiple Operating Systems Consolidate Applications on different time zones Complying with license agreements Flexibility and scalability Optimization of resources 4

3 Supported Operating Systems AIX 6.1 SOD for 4Q7 AIX 5.3 Enables Virtualization when on Power5 TL6 required for Power6 AIX 5. Minimum of ML4 required for Power5 TL1 required for Power6 AIX 5.1 Will not run on Power5 systems Does not support: Dynamic LPAR Memory Capacity Upgrade on Demand Dynamic Processor Sparing Dynamic CPU Guard Suse Linux, Redhat EL AS The Linux.6 kernel versions provide full virtualization support except for DLPAR memory Check required ML levels for each box Check required microcode levels on HMC, System P boxes and cards, especially fiber cards 5 3

4 Other GA dates to plan around June 1, 7 AIX 5. TL1 AIX 5.3 TL6 June 8, 7 P 57 HMC code v7 and new HMC 7314-G3 I/O drawers 5 new PCI-E adapters Shared dedicated Sept 7, 7 P5-57 upgrade to 4.gb p 57 with 1 dimm slots Sept 14, 7 Utility COD Nov 16, 7 P5-57 upgrade to 4.gb p 57 with 8 dimm slots SODs RHEL5 AIX 6.1 Hot node add Partition mobility Cold node repair Redundant SVP on P6 7 Software Make sure HMC and all boxes are at the latest microcode level Double-check supported HMC, AIX and firmware matrix System P Microcode can be found at: Latest p5 microcode is SF4-3 as of May 9, 7 P6 microcode level will be announced shortly HMC Corrective Service can be found at: Latest HMC Software version (as of May 9, 7 )is Power 4/4+ - v3v3.7 (dated Mar 6) Power5 v4r5. v5.r.1 v6.r1. V7 (n/a 5/9) Power6 (and 5 and 5+) V7 (n/a 5/9) With v7 you can use a direct web interface instead of WebSM NO support for 7315 Don t forget BIOS updates which are at the HMC locations above As of March 4 HMC maintenance is now a customer responsibility. Planning Need to keep HMC software and BIOS up to date Backups of the HMC Server and card microcode/firmware updates AIX maintenance planning All links valid as of 5/9/7 4

5 Planning Power4/4+ or AIX 5. or dedicated Each Power4/4+ LPAR must have the following 1 processor 56mb memory 1 boot disk 1 adapter to access the disk 1 Ethernet adapter to access the HMC An installation method such as NIM A means of running diagnostics The above also applies to Power5 partitions running AIX v5. ML4 or earlier versions of RHAS and SLES Also applies to dedicated LPARs 9 Planning Power5 Each Power5 LPAR running AIX v5.3 (or higher) with APV must have the following 1/1 processor 18mb memory (really needs more than this to run) 1 boot disk (virtual or real) 1 adapter to access the disk (virtual or real) 1 Ethernet adapter to access the HMC (virtual or real) An installation method such as NIM A means of running diagnostics 1 5

6 Power5 Memory In POWER5 you always have a Hypervisor Some memory is reserved for LPAR use Hypervisor - 56mb HPT (Hypervisor Page Table) Entries 1 per partition Reserves 1/64 of maximum memory setting For or more LPARS expect overhead to be at least 1gb memory Use 8% of memory as an estimate of overhead Do not forget it!!!! SPT replaces LVT tool used to get estimates for Power Planning Power6 Similar requirements to Power5 1/1 of a processor, etc Need APV to enable micro-partitioning and virtualization features Similar memory overhead PCI-E and PCI-X not interchangeable so you must know where a card is going Each CEC has 4 x PCI-E and x PCI-X I/O drawers are PCI-X P 57 all six disks on one adapter One media bay per CEC Give up a PCI-E slot if adding RIO drawers 1 6

7 Role of the HMC Required to partition any box Can use HMC to manage systems Provides a console to manage hardware Detecting, reporting and storing changes in hardware Service focal point (requires Ethernet) Vterms to partitions CuOD Virtualization The Overseer! 13 HMC versus IVM Integrated Virtualization Manager An LPAR that acts as the HMC Provides single system partitioning without a Hardware Management Console (HMC) Creates LPARs Manages virtual storage and virtual Ethernet Eliminates the need to purchase dedicated hardware console Included at no additional charge with purchase of optional Advanced POWER Virtualization feature or POWER Hypervisor and VIOS features. Limitations Must own all resources in the box All resources must therefore be controlled by VIOS Aimed at 55 and below 14 7

8 Terminology Hypervisor MicroPartitioning Shared Processor Pool Capped Uncapped Virtual Processors Entitled Capacity Virtual I/O Server Virtual Ethernet Shared Ethernet Adapter (SEA) Virtual SCSI Server 15 Planning for Virtual Virtual Ethernet Included in all Power5 systems Allows for in-memory connections between partitions Requires AIX v5.3 or Linux Up to 56 per partition Does NOT require APV All virtual servers below require the Advanced Power Virtualization feature Virtual I/O Server Provides virtual I/O sharing for shared Ethernet and virtual SCSI partitions Owns the real resources Shared Ethernet Adapter Virtual SCSI 16 8

9 More on Virtual Shared Ethernet Adapter Used to allow partitions to share a real Ethernet adapter Saves on dedicated I/O slots and adapters Virtual SCSI Server Disks on I/O server are defined as logical volumes and exported to client systems Client systems see these as SCSI disks Excellent Redbook draft Introduction to Advanced Power Virtualization SG APV Advanced Power Virtualization Feature Included on 59 and 595 Optional on all other p5 boxes Enables: MicroPartitioning Virtual I/O Server Shared Ethernet Adapter Virtual SCSI Server Partition Load Manager 18 9

10 POWER5 / 5+ virtualization architecture Workload management and provisioning Hardware Management Console* (HMC) Hypervisor Service processor AIX 5L V5.3 partitions AIX 5L kernels AIX 5L V5. Processors Memory Expansion slots Linux partitions Linux kernels Local devices and storage i5/os ** SLIC Virtual Networks Virtual Processors Virtual I/O Server VEnet VSCSI IVM* Unassigned on demand resources Virtual Storage Networks and network storage * Integrated Virtualization Manager (IVM) is disabled if HMC attached **Available on selected p5-57, p5-59 and p5-595 models 14 Micro-Partitioning Mainframe inspired technology Virtualized resources shared by multiple partitions Benefits Finer grained resource allocation More partitions (Up to 54) Higher resource utilization New partitioning model POWER Hypervisor Virtual processors Fractional processor capacity partitions Operating system optimized for Micro-Partitioning exploitation Virtual I/O 1

11 Shared processor partitions Micro-Partitioning allows for multiple partitions to share one physical processor Up to 1 partitions per physical processor Up to 54 partitions active at the same time One shared processor pool Dedicated processors are in the pool by default if their LPAR is powered off Partition s resource definition Minimum, desired, and maximum values for each resource Processor capacity (processor units) Virtual processors Capped or uncapped Capacity weight Dedicated memory Minimum of 18 MB and 16 MB increments Physical or virtual I/O resources 1 Micro-Partitioning technology Dynamic LPARs Whole Processors AIX 5L V5. Entitled capacity AIX 5L V5.3 AIX 5L V5.3 Max Min Micro-partitions Pool of 6 CPUs Linux Hypervisor AIX 5L V5.3 Linux Note: Micro-partitions are available via optional Advanced POWER Virtualization or POWER Hypervisor and VIOS features. i5/os V5R3** Micro-Partitioning technology allows each processor to be subdivided into as many as 1 virtual servers, helping to consolidate UNIX and Linux applications. Partitioning options Micro-partitions: Up to 54* Dynamic LPARs: Up to 3* Combination of both Configured via the HMC Number of logical processors Minimum/maximum Entitled capacity In units of 1/1 of a CPU Minimum 1/1 of a CPU Variable weight % share (priority) of surplus capacity Capped or uncapped partitions *on p5-59 and p5-595 ** on p5-57, p5-59, and p

12 Logical, Virtual or Real? In shared world there is no one to one relationship between real and virtual processors The dispatch unit becomes the VP 3 Math 11 and Consolidation Consolidation Issues Math 11 4 workloads A 6.3 B.7 C.48 D 4.87 Total = The proposed 8way is rated at LPARs use dedicated processors Is it big enough to run these workloads in 4 separate dedicated LPARs? NO 4 1

13 Why micropartitioning is important 8w 1.45g p65 is rperf w 1.45g p65 is 4.43 rperf So 1w is probably.1 Now back to Math 11 Wkld Rperf Processors Needed on p65 A (6.64) B.7 ( is >.1) C.48 ( is >.1) D ( is > 4.4) Total = (.1) Watch for granularity of workload 5 On Micropartitioned p5 8w 1.45g p65 was rperf 4w 1.65g p55q is.5 rperf So 1w on 55Q is probably 5.6 BUT we can use 1/1 of a processor and 1/1 increments Now back to Math 11 Wkld Rperf Processors Processors 65 55Q A B.7.45 C D Total = Watch for granularity of workload On the p5 we use fewer processors and we fit! p6 is even better! 6 13

14 Defining Processors Minimum, desired, maximum Maximum is used for DLPAR Shared or dedicated For shared: Capped Uncapped Variable capacity weight ( is default) Weight of is capped Minimum, desired and maximum Virtual Processors 7 Virtual Processors Partitions are assigned PUs (processor units) VPs are the whole number of concurrent operations Do I want my.5 as one big processor or 5 x.1 (can run 5 threads then)? VPs round up from the PU by default.5 Pus will be 1 VP.5 Pus will be 3 VPs You can define more and may want to Basically, how many physical processors do you want to spread your allocation across? This has charging implications VPs put a cap on the partition if not used correctly i.e. define.5 PU and 1 VP you can never have more than one PU even if you are uncapped Cannot exceed 1x entitlement VPs are dispatched to real processors Dispatch latency minimum is 1 millisec and max is 18 millisecs VP Folding Maximum is used by DLPAR Use commonsense when setting max VPs!!! 8 14

15 Virtual I/O Server Custom AIX v5.3 partition Commands have been customized Provides services for: Shared Ethernet Adapter Built on Virtual Ethernet Virtual SCSI Server Owns the physical resources Run if in production Can you have your cake and eat it? Can use multipath I/O Can do Etherchannels Maximum of virtual I/O slots Max of 56 VIO slots per partition Do not run other workloads here But do set tunables 9 Advanced POWER Virtualization option 1 CPU Virtual I/O server partition IVM Storage sharing Ethernet sharing Manager Server CPUs Linux Dynamically resizable 1 CPU i5/os V5R3** 4 CPUs AIX 5L V5. 6 CPUs AIX 5L V5.3 Virtual I/O paths Hypervisor PLM partitions LPAR 1 LPAR AIX 5L V5. AIX 5L V5.3 PLM agent PLM agent Hypervisor 6 CPUs Micro-Partitioning AIX 5L V5.3 Linux Linux AIX 5L V5.3 AIX 5L V5.3 Unmanaged partitions LPAR 3 Linux AIX 5L V5.3 AIX 5L V 5.3 Virtual I/O Server Shared Ethernet Shared SCSI and Fibre Channel-attached disk subsystems Supports AIX 5L V5.3 and Linux* partitions Micro-Partitioning Share processors across multiple partitions Minimum partition 1/1 th processor AIX 5L V5.3, Linux*, or i5/os** Partition Load Manager Balances processor and memory request No longer a default on P6 Managed via HMC or IVM*** * SLES 9 or RHEL AS 4 and above **Available on selected p5-57, p5-59 and p5-595 models ***IVM on p5-56q and below 5 15

16 Virtual Ethernet Enables inter-partition communication. In-memory point to point connections Physical network adapters are not needed. Similar to high-bandwidth Ethernet connections. Supports multiple protocols (IPv4, IPv6, and ICMP). No Advanced POWER Virtualization feature required. POWER5 Systems AIX 5L V5.3 or appropriate Linux level Hardware management console (HMC) 31 Virtual networking External Servers Virtual Ethernet helps reduce hardware costs by sharing LAN adapters VIOS POWER5 Server Micro-partitions VLAN 1 VLAN VLAN 3 vscsi vlan AIX 5L V5.3 Linux AIX 5L V5.3 Linux Ethernet Switch Virtual Ethernet Partition to partition communication Requires AIX 5L V5.3 and POWER5 Shared Ethernet Adapter Provides access to outside world Uses Physical Adapter in the Virtual I/O Server VLAN Virtual LAN Provide ability for one adapter to be on multiple subnets Provide isolation of communication to VLAN members Allows a single adapter to support multiple subnets Shared Ethernet Adapter Virtual Ethernet Switch POWER Hypervisor IEEE VLANS Up to 496 VLANS Up to venet adapters 1 VLANS per venet adapter 7 16

17 Virtual SCSI Allows sharing of storage devices Vital for shared processor partitions Overcomes potential limit of adapter slots due to Micro- Partitioning Allows the creation of logical partitions without the need for additional physical resources Allows attachment of previously unsupported storage solutions 33 Virtual SCSI External Storage A1 B1 A B B3 A3 B4 A4 A5 B5 VIOS owns physical disk resources LVM based storage on VIO Server Physical Storage can be SCSI or FC Local or remote Virtual I/O helps reduce hardware costs by sharing disk drives Shared Fiber Chan Adapter Shared SCSI Adapter v S C SI VIOS POWER5 Server Micro-partitions v L A N AIX 5L V5.3 Linux Virtual SCSI POWER Hypervisor AIX 5L V5.3 A1 A B1 B B3 Linux A3 Micro-partition sees disks as vscsi (Virtual SCSI) devices Virtual SCSI devices added to partition via HMC or IVM LUNs on VIOS accessed as vscsi disk VIOS must be active for client to boot Multiple LPARs can use same or different physical disk Configure as logical volume on VIOS Appear a hdisk on the micro-partition Can assign entire hdisk to a single client 9 17

18 Workload Manager Around since AIX v4.3.3 Used to control resources in one O/S instance Controls: CPU Memory I/O Bandwidth References: SG AIX 5l Workload manager Search on Jaqui Lynch There is a WLM article in there 35 Capacity on Demand for POWER5 and POWER5+ systems Capacity Upgrade on Demand Upgrade system with processors and/or memory No special contracts, no required monitoring (no ability to turn off the capacity) Purchase an activation On/Off Capacity on Demand Temporary use of requested number of processors or amount of memory Client selects the capacity and activates the resource (registered system) Capacity can be turned on and off by the client Information reported to IBM Reserve Capacity on Demand Processor resources only (processor days) Capacity can be turned on and off by the client Prepaid debit agreement Requires AIX 5L V5.3 or Linux and Advanced POWER Virtualization Trial Capacity on Demand Allow clients to test the effects of additional processors and/or memory Partial or total activation of processors and memory Resources available for fixed time Available on select models 18

19 Capacity on Demand for POWER6 systems Capacity Upgrade on Demand Upgrade system with processors and/or memory No special contracts, no required monitoring (no ability to turn off the capacity) Purchase an activation On/Off Capacity on Demand Temporary use of requested number of processors or amount of memory Client selects the capacity and activates the resource (registered system) Capacity can be turned on and off by the client Information reported to IBM Utility Capacity on Demand (3Q7) Processor resources within the Shared Processor Pool only Usage measured in processor minute increments Capacity can be turned on and off by the client Billing based on usage reported via a website interface Trial Capacity on Demand Allow clients to test the effects of additional processors and/or memory Partial or total activation of processors and memory Resources available for fixed time 37 Hints and Tips Which LPAR is your service LPAR? How will you do installs Allocate cd? NIM? Backup Methodology? Especially for HMC!! If using virtualization planning is more critical than ever Ensure Inventory scout is working on all LPARs and that VPD is being uploaded to IBM can now use Web SSL instead of dial or VPN Create a partition layout in advance Include devices, etc I/O devices are allocated at the slot level Are cards going in CEC or I/O drawer? Which I/O drawer? Affects the number of PCI-E and PCI-X adapters Boot disks I/O drawer or 14, Raid, Fiber Have VIOS control all boot disks? P6 CEC one LPAR owns all 6 disks P5 CEC 6 disks are split into x 3 packs and each trio can be owned by a different LPAR Check the number of LPARs per boot disk 3bit kernel versus 64bit kernel 3 bit supports up to 96gb memory Need 64bit kernel to have more than 96gb in an LPAR Need 64bit kernel for more than 16 processors in an LPAR Moot point as no 3 bit in AIX v6.1 anyway 38 19

20 PLANNING SHEET NOTE - NIM server will use onboard ethernets Dual port 6.53 Copper Instance Boot ram fiber ethernet VPS cpu rperf SPP VIO VIO VIO Disks 57.g p57.g CPUS BOOT ETHER SAN lp N N N N lp Y Y Y Y lp Y Y Y Y lp Y Y Y Y NIM N N N N Overhead 4 VIO Server VIO Server server Total adapters 7 Then have an additional spreadsheet that maps each lpar to adapters And I/O drawers, etc First disk on each VIO server is the VIO server rootvg, not for servicing client LPARs Documentation is critical do it ahead of time More Sizing - original Server LPAR CPUs Memory rperf AIX KVA Watts BTU/hr GB p ghz 4 way LPAR LPAR p ghz 4 way LPAR LPAR p ghz 4 way LPAR LPAR p ghz 4 way LPAR LPAR p ghz 8 way LPAR LPAR LPAR LPAR p ghz 8 way LPAR LPAR x I/O drawers rperf taken from rsperfs146.doc from IBM

21 So, let s assume we can migrate everything to AIX v5.3 and take advantage of micro-partitioning. Let s also assume we have policies in place as follows: Per LPAR x fiber cards x internal boot disks x 1/1/1 Ethernet cards 4gb memory per processor if database gb memory per processor for other In the unconsolidated environment above we would have the following: Disks 8 Fiber cards 8 Ethernet cards 8 Memory 88GB + 8% overhead = 96GB Processors 3 x 1.65ghz rperf 71.4 If we moved this to a purely AIX v5.3 environment (no VIOS) on the new p5+-57 with 1.9ghz processors using shared processors we would require the following: Disks 8 Fiber cards 8 Ethernet cards 8 Memory 88GB + 8% overhead = 96GB Processors 14 x 1.9ghz rperf NB rperf for p5 assumes SMT is turned on. If running 5. or without SMT then divide the number by 1.3 Given the architecture of the 57 we would have the ability to boot 8 LPARs of our total 14 from 3- packs in the CECs. So we would need additional I/O drawers for the other 6. The 57 also provides only 4 PCI-X slots total so an additional 3 slots would be needed in I/O drawers. A 7311-D I/O drawer provides 7 PCI-X slots and x 6-packs for disk. So we would need a total of 5 x I/O drawers to support the necessary cards. 3 of the I/O drawers would also each have 4 disks ( per 6-pack) to support the final 6 lpars boot disks Environmentals on the new configuration would look like this: Servers KVA Watts BTU/HR OLD 9.4 8,58 8, way 1.9g , 17,748 5x7311-D 1.8 1,7 5,85 TOTAL 7.7 6,9 3,553 SAVINGS ,68 5,96 1

22 Adding VIOS LPAR Fiber Ethernet Disks Uses Disk Fiber Ethernet OLD Old VIO? NEW NEW NEW LPAR1 y LPAR y LPAR3 y LPAR4 y LPAR5 y LPAR6 y LPAR7 y LPAR8 y LPAR9 n LPAR1 n LPAR11 n LPAR1 n LPAR13 n LPAR14 n VIOS (uses 3gb) y Savings over old Saves slots and can Reduce by I/O drawers Note assumes VIO servers booting from internal disk and providing client boot disks from SAN Sizing thoughts Correct amount of processor power Balanced memory, processor and I/O Min, desired and max settings and their effect on system overhead Memory overhead for page tables, TCE, etc Shared or dedicated processors Capped or uncapped If uncapped number of virtual processors Expect to safely support 3 LPARs booting from a 146gb disk through a VIO server Don t forget to add disk for LPAR data for clients 44

23 Ethernet See chapter 6 of SG redbook Advanced POWER Virtualization on IBM Eserver p5 Servers: Architecture and Performance Considerations for information on Vlan benchmark results with different processing power and mtu sizes Short summary MTU=15 needs 1 x 1.65ghz processor per gigabit adapter to drive the adapter fully MTU=9 needs about half a processor Has calculators in there for sizing for SEA 51mb memory is fine if only SEA as buffers and data structures are fairly small Other Memory Needs (P6) Each active ethernet port 1MB So quadport on base is 48MB overhead 45 Virtual SCSI See chapter 6.8 of SG redbook Short summary A little extra latency using virtual scsi (.3 to.6 ms per I/O) Memory allocation is critical For large I/O configurations and high data rates VIOS may need 1gb Processor allocation is critical has calculations for processors needed depending on workload 46 3

24 Other sizing Workload estimator Used to size servers with one or more workloads System Planning Tool Virtual I/O Server Sizing Guidelines Whitepaper Covers for ethernet: Proper sizing of the Virtual I/O server Threading or non-threading of the Shared Ethernet Separate micro-partitions for the Virtual I/O server Other k.htm m SPT 1 4

25 SPT SPT 3 5

26 SPT4 Maximums 54 partitions per server or 1 * # processors (whichever is smaller) HMC 3 servers/54 partitions 64 Virtual processors per partition 56 Virtual Ethernet adapters per partition 1 VLANs per VE adapter 16 VEs per physical adapter (SEA) with 1 VLANS per 5 6

27 LPAR Notes Power5 Max LPARS = 1x #processors Only Power5 or 5+ on the same HMC if at v6 Current 731 HMC can be upgraded to v7 to add Power6 support All use 19 racks but very specific power needs p5-5 and p5-55 Only 7311-D I/O drawer supported Comes with 1 x 4pack internal another can be added P5-56Q Similar to p5-57 but no I/O drawers, uses quadcore and only modules p5-57 (each 4-way) x 3 packs of disk internal (on separate SCSI buses) Supports x LPARs without extra SCSI cards 7311-D I/O drawer has x 6 packs SCSI cards needed and must be in slots 4 and 7 P5s Require AIX v5. ML4 at a minimum 53 LPAR Notes Power6 Max LPARS = 1x #processors Power5, 5+ and 6 on the same HMC (731 v7 or 74) 7315 HMC not supported Requires HMC code v7 Can use new Web interface All use 19 racks but very specific power needs p6-57 (each 4-way) 1 x 6 packs of disk internal (on one SCSI bus per six-pack) 1 x media bay per Supports 1 x LPAR without extra SCSI cards Supports 7311-D, 7311-D11 RIO drawers but you have to give up a PCI-E slot 7311-D I/O drawer has x 6 packs SCSI cards needed and must be in slots 4 and 7 Supports new G3 drawer without using a PCI-E slot To get redundancy you must have 3 x FC 565 power regulators per CEC P6 requires AIX v5. TL1 or AIX v5.3 TL6 or an enabled version of Linux 54 7

28 55 IVE Notes Adapter ties directly into GX Bus No Hot Swap No Swap Out for Different Port Types (1GbE, etc.) Not Supported for Partition Mobility, except when assigned to VIOS Option 1 on Previous Chart Partition performance is the same as a real adapter No VIOS Overhead Intra-partition performance may be better than using Virtual Ethernet 56 8

29 Planned Live Partition Mobility with POWER6 Allows migration of a running LPAR to another physical server Reduce impact of planned outages Relocate workloads to enable growth Provision new technology with no disruption to service Save energy by moving workloads off underutilized servers Movement to a different server with no loss of service Virtualized Virtualized SAN SAN and and Network Network Infrastructure Infrastructure 57 Partition Mobility Pre-Reqs All Systems in a Migration Set must be managed by the same HMC HMC will have orchestration code to control migration function All Systems in a Migration Set must be on the same subnet. All Systems in a Migration Set must be SAN connected to shared physical disk no VIOS LVM-based disks. ALL I/O must be shared/virtualized. Any dedicated I/O adapters must be deallocated prior to migration. Systems must be firmware compatible (within one release) 58 9

30 Partition Mobility Other Considerations Intended Use: Workload Consolidation Workload Balancing Workload Migration to Newer Systems Planned CEC outages for maintenance Unplanned CEC outages where error conditions are picked up ahead of time. What it is not: A Replacement for HACMP or other clustering. Not automatic LPARs cannot be migrated from failed CECs Failed OS s cannot be migrated Long Distance Support Not Available in First Release 59 POWER6 Rollout Other Random Items AIX Version 6.1 Open Beta Starts July/August 7 Open to everyone P5 / p5+ Upgrades to POWER6 have a lot of rules/regulations and varying dates of availability. Note new Service Stategies for both AIX (5.3 TL6) and Firmware Starting with TL6 support will last for years on single TL. New hardware support will no longer be tied to a TL. This is it. Service Agent is required on POWER6 systems and will be part of CE Installation Look at Tivoli and IBM Director for Comprehensive Systems Management Performance and Capacity ITM Keeping Track of Everything TADDM / CCMDB 6 3

31 Tools lparstat h percentage spent in Hypervisor and number of Hcalls lparstat i Info on entitled capacity, setup info, etc mpstat s SMT info mpstat d Detailed affinity and migration statistics sar P ALL topas L nmon Note you can t chargeback by processor or %user anymore as you will see 61 Traps for Young Players Under-sizing VIOS Over-committing boot disks Forgetting Memory and processor Overhead Planning for what should and should not be virtualized Misunderstanding needs Workload Granularity Undersizing memory and overhead Hypervisor I/O drawers, etc VIOS requirements Setting maximums Chargeback and capacity planning may need to be changed 6 31

32 References IBM Redbooks These are updated regularly SG4-794 Advanced Power Virtualization on IBM p5 servers Introduction and Basic Configuration SG Advanced Power Virtualization on IBM p5 servers Architecture and Performance Considerations SG Virtualization and Clustering Best Practices Red piece 4194 Advanced Power Virtualization Best Practices Red piece 44 APV VIOS Deployment Examples The Complete Partitioning Guide for IBM eserver System P Servers System P LPAR Planning Redpiece Logical Partition Security in the IBM eserver pseries 69 Technical Overview Redbooks for p5, p55 and p57, etc SG Partitioning Implementation on p5 and Openpower Servers eserver Magazine Several articles focused on Virtualization Find more on Mainline at: 63 Questions? 64 3

Planning and Sizing Virtualization

Planning and Sizing Virtualization Planning and Sizing Virtualization Jaqui Lynch Architect, Systems Engineer Mainline Information Systems http://www.circle4.com/papers/cmgvirt.pdf 1 What is Virtualization? Being able to dynamically move

More information

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004 pseries Partitioning AIX 0 Jaqui Lynch USERblue 2004 Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubaixpart04.pdf Agenda Partitioning Concepts Hardware Software Planning Hints and Tips References

More information

Planning for Virtualization on System P

Planning for Virtualization on System P Planning for Virtualization on System P Jaqui Lynch Systems Architect Mainline Information Systems Jaqui.lynch@mainline.com com http://www.circle4.com/papers/powervm-performance-may09.pdf http://mainline.com/knowledgecenter

More information

The Power of PowerVM Power Systems Virtualization. Eyal Rubinstein

The Power of PowerVM Power Systems Virtualization. Eyal Rubinstein The Power of PowerVM Power Systems Virtualization Eyal Rubinstein deyal@il.ibm.com The Power Equation: Power = i + p System i i515 i525 i550 i570 i595 IBM BladeCenter BladeCenter JS12/22/23 Express BladeCenter

More information

Application and Partition Mobility

Application and Partition Mobility IBM System p Application and Mobility Francis COUGARD IBM Products and Solutions Support Center Montpellier Copyright IBM Corporation 2009 Index Application and Mobility Presentation Videocharger and DB2

More information

IBM _` p5 570 servers

IBM _` p5 570 servers Innovative, modular, scalable, mid-range systems designed for the on demand world IBM _` p5 570 servers and departmental or regional server deployments. The rack-mount p5-570 delivers power, flexibility,

More information

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version :

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version : IBM 000-180 p5 and pseries Enterprise Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-180 A. The LPAR Configuration backup is corrupt B. The LPAR Configuration

More information

p5 520 server Robust entry system designed for the on demand world Highlights

p5 520 server Robust entry system designed for the on demand world Highlights Robust entry system designed for the on demand world IBM p5 520 server _` p5 520 rack system with I/O drawer Highlights Innovative, powerful, affordable, open and adaptable UNIX and Linux environment system

More information

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM System p5 570 POWER5+ processor and memory features offer new options Hardware Announcement February 14, 2006 IBM System p5 570 POWER5+ processor and memory features offer new options Overview The System p5 570 offers new POWER5+ processor options with 64-bit 1.9 GHz and

More information

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation IBM SYSTEM POWER7 PowerVM Jan Kristian Nielsen jankn@dk.ibm.com - +45 28803310 Erik Rex Rex@dk.ibm.com - +45 28803326 PowerVM: Virtualization Without Limits Reduces IT infrastructure costs Improves service

More information

iseries Tech Talk Linux on iseries Technical Update 2004

iseries Tech Talk Linux on iseries Technical Update 2004 iseries Tech Talk Linux on iseries Technical Update 2004 Erwin Earley IBM Rochester Linux Center of Competency rchlinux@us.ibm.com Agenda Enhancements to the Linux experience introduced with i5 New i5/os

More information

IBM System p5 550 and 550Q Express servers

IBM System p5 550 and 550Q Express servers The right solutions for consolidating multiple applications on a single system IBM System p5 550 and 550Q Express servers Highlights Up to 8-core scalability using Quad-Core Module technology Point, click

More information

Virtualization Benefits IBM Corporation

Virtualization Benefits IBM Corporation Virtualization Benefits 1 Virtualization Benefits CPU Utilization 100 90 80 70 60 50 40 30 20 10 0 8:00 10:00 12:00 2:00 4:00 Time Purchased Peak Average Increase Utilization Non-virtualized servers often

More information

System i and System p. Creating a virtual computing environment

System i and System p. Creating a virtual computing environment System i and System p Creating a virtual computing environment System i and System p Creating a virtual computing environment Note Before using this information and the product it supports, read the information

More information

Power Systems with POWER7 and AIX Technical Sales

Power Systems with POWER7 and AIX Technical Sales Power Systems with POWER7 and AIX Technical Sales Number: 000-107 Passing Score: 800 Time Limit: 120 min File Version: 26.6 http://www.gratisexam.com/ IBM 000-107 EXAM QUESTIONS & ANSWERS Exam Name: Power

More information

IBM System p5 510 and 510Q Express Servers

IBM System p5 510 and 510Q Express Servers More value, easier to use, and more performance for the on demand world IBM System p5 510 and 510Q Express Servers System p5 510 or 510Q Express rack-mount servers Highlights Up to 4-core scalability with

More information

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX KillTest Q&A Exam : 000-108 Title : Enterprise Technical Support for AIX and Linux -v2 Version : Demo 1 / 7 1.Which power reduction technology requires a software component in order to be activated? A.

More information

IBM System p 570 server

IBM System p 570 server Modular and scalable systems for business flexibility and IT efficiency IBM System p 570 server IBM POWER5+ processor-based System p5 570 server, for resource optimisation, secure and dependable performance

More information

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1. Version: Demo Vendor: IBM Exam Code: C9010-251 Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1 Version: Demo QUESTION 1 What is a characteristic of virtualizing workloads? A. Processors are

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-106 EXAM QUESTIONS & ANSWERS Number: 000-106 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ IBM 000-106 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers C4040-251 Number: C4040-251 Passing Score: 800 Time Limit: 120 min File Version: 5.0 http://www.gratisexam.com/ IBM C4040-251 Questions & Answers Power Systems with POWER8 Scale-out Technical Sales Skills

More information

IBM POWER7 Systems Express Blades Quick Reference Guide April 2012

IBM POWER7 Systems Express Blades Quick Reference Guide April 2012 IBM Systems IBM POWER7 Systems Blades Quick Reference Guide. PS700 PS701 PS702 PS703 PS70 # of processor sockets 1 1 2 2 3.0 GHz (-core) 3.0 GHz (-core) 3.0 GHz (-core) 2. GHz (-core) 2. GHz (-core) 32

More information

IBM POWER7 Systems Express Blades Quick Reference Guide October 2012

IBM POWER7 Systems Express Blades Quick Reference Guide October 2012 IBM Systems IBM POWER7 Systems Blades Quick Reference Guide. PS700 PS701 PS702 PS703 # of processor sockets 1 1 2 2 3.0 GHz (-core) 3.0 GHz (-core) 3.0 GHz (-core) 2. GHz (-core) - GHz (cores/socket) -

More information

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo Vendor: IBM Exam Code: C4040-108 Exam Name: Enterprise Technical Support for AIX and Linux -v2 Version: Demo QUESTION 1 Which power reduction technology requires a software component in order to be activated?

More information

Live Partition Mobility Update

Live Partition Mobility Update Power Systems ATS Live Partition Mobility Update Ron Barker Power Advanced Technical Sales Support Dallas, TX Agenda Why you should be planning for partition mobility What are your options? Which is best

More information

IBM p5 Virtualization Technical Support AIX 5L V5.3. Download Full Version :

IBM p5 Virtualization Technical Support AIX 5L V5.3. Download Full Version : IBM 000-062 p5 Virtualization Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-062 A. Virtual Ethernet B. Micro-Partitioning C. Virtual I/O Server D.

More information

IBM POWER7 Systems Express Blades Quick Reference Guide November 2011

IBM POWER7 Systems Express Blades Quick Reference Guide November 2011 IBM POWER7 Systems Blades Quick Reference Guide. PS700 PS701 PS702 PS703 PS70 # of processor sockets 1 1 2 2 3.0 GHz (-core) 3.0 GHz (-core) 3.0 GHz (-core) 2. GHz (-core) disk bays / GB/TB storage - GB

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 000-180 Title : P5 and pseries Enterprise Technical Support Aix 5L V5.3 Vendors : IBM Version : DEMO

More information

Partitioning Computers. Rolf M Dietze,

Partitioning Computers. Rolf M Dietze, Partitioning Computers Rolf M Dietze rolf.dietze@dietze-consulting.de Consolidation/Partitioning Hardware Partitioning Resource Direction Resource Shareing Soft Partitioning Hypervisor Classifying Server

More information

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor IBM United States Announcement 107-099, dated February 14, 2007 IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor Description...2 Publications... 4 Services...4

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-105 EXAM QUESTIONS & ANSWERS Number: 000-105 Passing Score: 650 Time Limit: 60 min File Version: 65.5 http://www.gratisexam.com/ IBM 000-105 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : 000-122 Title : Power Systems with POWER7 Common Sales Skills -v2 Vendor : IBM Version : DEMO 1 / 4 Get Latest & Valid

More information

Live Partition Mobility

Live Partition Mobility Live Partition Mobility Jaqui Lynch lynchj@forsythe.com Presentation at: http://www.circle4.com/forsythe/lpm2014.pdf 1 1 Why Live Partition Mobility? LPM LIVE PARTITION MOBILITY Uses Server Consolidation

More information

Flagship UNIX and Linux system designed to drive business innovation

Flagship UNIX and Linux system designed to drive business innovation Flagship UNIX and Linux system designed to drive business innovation IBM p5 595 server Highlights Provides the power for missioncritical workloads with up to 64 IBM POWER5 processors Helps to lower costs

More information

Power Systems with POWER8 Scale-out Technical Sales Skills V1

Power Systems with POWER8 Scale-out Technical Sales Skills V1 Power Systems with POWER8 Scale-out Technical Sales Skills V1 1. An ISV develops Linux based applications in their heterogeneous environment consisting of both IBM Power Systems and x86 servers. They are

More information

IBM Power Systems Technical Support for AIX and Linux. Download Full Version :

IBM Power Systems Technical Support for AIX and Linux. Download Full Version : IBM 000-330 Power Systems Technical Support for AIX and Linux Download Full Version : https://killexams.com/pass4sure/exam-detail/000-330 A. 520 2-core, 2 active B. 550 2-core, 2 active C. 570 8-core,

More information

IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems

IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems Announcement ZG08-0790, dated October 7, 2008 IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems Table of contents 2 Key prerequisites 30 Technical information 2 Planned availability

More information

Virtualization Technical Support for AIX and Linux - v2

Virtualization Technical Support for AIX and Linux - v2 IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 Version: 5.0 Topic 1, Volume A QUESTION NO: 1 An administrator is attempting to configure a new deployment of 56 POWER7 Blades across

More information

IBM Power 740 Express server

IBM Power 740 Express server IBM Power 740 Express server High performance, reliable, expandable midsize database and consolidation server Highlights For small-to-midsize database servers Ideal for running today s computeintensive

More information

IBM Virtualization Technical Support for AIX and Linux - v2.

IBM Virtualization Technical Support for AIX and Linux - v2. IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 http://killexams.com/exam-detail/000-109 QUESTION: 170 A Power Systems server has two HMCs connected to its Flexible Service Processor

More information

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades October 2012 IBM Power Systems servers and IBM BladeCenter blade servers using IBM POWER6 and POWER6+ processors are described

More information

New IBM POWER6 processors for the Power 570 enable you to get more processing power with fewer processors

New IBM POWER6 processors for the Power 570 enable you to get more processing power with fewer processors , dated October 7, 2008 New IBM POWER6 processors for the Power 570 enable you to get more processing power with fewer processors Table of contents 1 Key prerequisites 10 Services 1 Planned availability

More information

Flagship UNIX and Linux server designed to drive business. innovation. Highlights

Flagship UNIX and Linux server designed to drive business. innovation. Highlights Flagship UNIX and Linux server designed to drive business innovation IBM p5 595 server Highlights Provides the power for missioncritical workloads with up to 64 IBM POWER5 processors Helps to lower costs

More information

BMC Capacity Optimization Extended Edition AIX Enhancements

BMC Capacity Optimization Extended Edition AIX Enhancements BMC Capacity Optimization Extended Edition 9.5.1 AIX Enhancements Support for AIX Active Memory Expansion (AME) mode Metrics displayed in BCO AIX PowerVM view for CPU and Memory Allocation Frame name,

More information

February 5, 2008 Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM

February 5, 2008 Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM by Brad Day with Simon Yates and Rachel Batiancila EXECUTIVE SUMMARY IBM s PowerVM (formerly Advanced POWER Virtualization)

More information

A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension

A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension SHARE in Anaheim March 2011 A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension Session ID: zzs18 Glenn Anderson, IBM Training 2011 IBM Corporation 1 2 3 1999 History of Blades.. Data center

More information

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options Hardware Announcement October 5, 2004 IBM p5 520 and 550 1-way and 2-way 1.5 GHz processors offer new processor speed options Overview IBM p5 520 and 550 offer new POWER5 processor options with the optional

More information

Power 795. New High-end 24 to 256 Cores

Power 795. New High-end 24 to 256 Cores New Power 795 New High-end 24 to 256 Cores 8 8 TB memory TurboCore 3.7, 4.0 or 4.25 GHz 1,000 VMs* with PowerVM Capacity on Demand Enterprise RAS 24x7 Warranty PowerCare 1 * Statement of Direction System

More information

Experiences with VIOS support for IBM i

Experiences with VIOS support for IBM i Experiences with VIOS support for IBM i Pete Stephen, Power Systems / AIX Architect Sirius Computer Solutions Pete.Stephen@siriuscom.com Agenda VIO overview Virtualization Trends. PowerVM and how do I

More information

HMC The New Console on the Block John Still

HMC The New Console on the Block John Still HMC The New Console on the Block John Still Objectives Console History Introducing the Hardware Management Console (HMC) Planning for HMC and i5 Guided Setup Wizard HMC Management Remote Access System

More information

IBM Virtual I/O Server helps maximize physical

IBM Virtual I/O Server helps maximize physical Software Announcement July 13, 2004 IBM Virtual I/O Server helps maximize physical resources on IBM pseries POWER5 systems; Partition Load Manager helps maximize CPU/memory on pseries POWER5 servers that

More information

IBM SAP Technical Brief. Live Partition Migration of SAP Systems Under Load. IBM SAP International Competence Center Walldorf, Germany

IBM SAP Technical Brief. Live Partition Migration of SAP Systems Under Load. IBM SAP International Competence Center Walldorf, Germany IBM SAP Technical Brief Live Partition Migration of SAP Systems Under Load IBM SAP International Competence Center Walldorf, Germany Version: 1.0 Status: April 2011 Page 1 of 19 Preface Edition Notice

More information

An Energy, Memory, and Performance Analysis Case Study on the IBM System z10 BC

An Energy, Memory, and Performance Analysis Case Study on the IBM System z10 BC An Energy, Memory, and Performance Analysis Case Study on the IBM System z10 BC June 5, 2009 Elisabeth Stahl Michael Buechele John P. Rankin IBM Systems and Technology Group Executive Overview As part

More information

IBM Systems: Helping the world use less servers

IBM Systems: Helping the world use less servers Agenda Server Consolidation Reasons Server Consolidation Methodology Power Systems Server Consolidation Server Consolidation Examples Demo of SCON Tool Mike Rede Field Technical Sales Specialist mrede@us.ibm.com

More information

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview PowerVM simplification enhancements PowerVM infrastructure overview IBM PowerVM is the virtualization solution that enables workload consolidation for AIX, IBM i, and Linux environments on IBM Power Systems

More information

New IBM Power 795 system delivers outstanding performance, scalability, reliability, and manageability for demanding commercial workloads

New IBM Power 795 system delivers outstanding performance, scalability, reliability, and manageability for demanding commercial workloads IBM United States Hardware Announcement 1-15, dated August 17, 2 New IBM Power 795 system delivers outstanding performance, scalability, reliability, and manageability for demanding commercial workloads

More information

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2. Version: Demo Vendor: IBM Exam Code: C4040-226 Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2 Version: Demo Question No : 1 A customer with a POWERS 520 running IBM i is debating consolidating

More information

Pass4Sure.C _83,Q&A

Pass4Sure.C _83,Q&A Pass4Sure.C4040-251_83,Q&A Number: C4040-251 Passing Score: 800 Time Limit: 120 min File Version: 16.02 http://www.gratisexam.com/ These are the most accurate study questions. Just focus on these and sit

More information

IBM PowerVM. Virtualization without limits. Highlights. IBM Systems and Technology Data Sheet

IBM PowerVM. Virtualization without limits. Highlights. IBM Systems and Technology Data Sheet IBM PowerVM Virtualization without limits Highlights Deliver services with superior economics by consolidating virtualized workloads Deliver services faster by automating deployment of virtual machines

More information

IBM POWER8 100 GigE Adapter Best Practices

IBM POWER8 100 GigE Adapter Best Practices Introduction IBM POWER8 100 GigE Adapter Best Practices With higher network speeds in new network adapters, achieving peak performance requires careful tuning of the adapters and workloads using them.

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

IBM i on a Power Blade Read-me First. Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN

IBM i on a Power Blade Read-me First. Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN IBM i on a Power Blade Read-me First Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN vess@us.ibm.com October 30 th, 2009 1 This read-me first document provides detailed instructions on

More information

Disk I/O and the Network

Disk I/O and the Network Page 1 of 5 close window Print Disk I/O and the Network Increase performance with more tips for AIX 5.3, 6.1 and 7 October 2010 by Jaqui Lynch Editor s Note: This is the concluding article in a two-part

More information

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary v1.0 January 8, 2010 Introduction This guide describes the highlights of a data warehouse reference architecture

More information

IBM Power 550 Express Edition: Exceptional reliability, availability, and serviceability for entry and medium-size enterprises

IBM Power 550 Express Edition: Exceptional reliability, availability, and serviceability for entry and medium-size enterprises IBM Europe Announcement ZG08-0329, dated April 2, 2008 IBM Power 550 Express Edition: Exceptional reliability, availability, and serviceability for entry and medium-size enterprises Description...2 Product

More information

WebSphere. Virtual Enterprise Version Virtualization and WebSphere Virtual Enterprise Version 6.1.1

WebSphere. Virtual Enterprise Version Virtualization and WebSphere Virtual Enterprise Version 6.1.1 WebSphere Virtual Enterprise Version 6.1.1 Virtualization and WebSphere Virtual Enterprise Version 6.1.1 ii : Contents Preface............... v Chapter 1. Virtualization and WebSphere Virtual Enterprise...........

More information

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades August 2013 IBM Power Systems servers and IBM BladeCenter blade servers using IBM POWER6 and POWER6+ processors are described

More information

IBM Power Systems Facts and Features. December 2009

IBM Power Systems Facts and Features. December 2009 IBM Systems Facts and Features December 2009 1 Table of Contents BladeCenter JS12/JS22...3 BladeCenter JS23/JS43...4 520 / 550...5 560...6 570...7 575...8 595...9 System Unit Details...10 System Unit Details

More information

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai June 2012 @Dubai IBM Power Academy IBM PowerVM memory virtualization Luca Comparini STG Lab Services Europe IBM FR June,13 th 2012 @IBM Dubai Agenda How paging works Active Memory Sharing Active Memory

More information

White Paper. Server Virtualization on UNIX Systems: A comparison between HP Integrity Servers with HP-UX and IBM Power Systems with AIX

White Paper. Server Virtualization on UNIX Systems: A comparison between HP Integrity Servers with HP-UX and IBM Power Systems with AIX 89 Fifth Avenue, 7th Floor New York, NY 10003 www.theedison.com 212.367.7400 White Paper Server Virtualization on UNIX Systems: A comparison between HP Integrity Servers with HP-UX and IBM Power Systems

More information

Sub-capacity licensing for select IBM Passport Advantage eligible programs running on x86 servers helps improve flexibility and price/performance

Sub-capacity licensing for select IBM Passport Advantage eligible programs running on x86 servers helps improve flexibility and price/performance Software Announcement April 25, 2006 Sub-capacity licensing for select IBM Passport Advantage eligible programs running on x86 servers helps improve flexibility and price/performance Overview IBM continues

More information

Historical Collection Best Practices. Version 2.0

Historical Collection Best Practices. Version 2.0 Historical Collection Best Practices Version 2.0 Ben Stern, Best Practices and Client Success Architect for Virtualization and Cloud bstern@us.ibm.com Copyright International Business Machines Corporation

More information

IBM i supports additional IBM POWER6 hardware

IBM i supports additional IBM POWER6 hardware , dated April 28, 2009 IBM i supports additional IBM POWER6 hardware Table of contents 1 At a glance 6 Product number 1 Overview 6 Ordering information 2 Key prerequisites 8 Prices 2 Planned availability

More information

Executive Summary. At a high level there are several options if you have Power Nodes:

Executive Summary. At a high level there are several options if you have Power Nodes: Executive Summary The IBM PureFlex System brought new levels of integration and quick time to deploy advantages that were enjoyed by many customers. A central piece of the integration was the Flexible

More information

IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide

IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide This IBM Redbooks Solution Guide introduces IBM PowerVM virtualization technologies on IBM

More information

IBM Power Systems Facts and Features: Enterprise and Scale-out Systems with POWER8 Processor Technology. March 2016

IBM Power Systems Facts and Features: Enterprise and Scale-out Systems with POWER8 Processor Technology. March 2016 March 2016 IBM Systems Facts and Features: Enterprise and Scale-out Systems with POWER8 Processor Technology IBM Systems servers and IBM BladeCenter blade servers using IBM POWER7 and POWER7+ processors

More information

IBM Power 755 server. High performance compute node for scalable clusters using InfiniBand architecture interconnect products.

IBM Power 755 server. High performance compute node for scalable clusters using InfiniBand architecture interconnect products. IBM Power 755 server High performance compute node for scalable clusters using InfiniBand architecture interconnect products. Highlights Optimized for running highly parallel computationally intensive

More information

Exam Name: IBM System p Solution Sales

Exam Name: IBM System p Solution Sales Exam Code: 000-229 Exam Name: IBM System p Solution Sales Vendor: IBM Version: DEMO Part: A 1: Which of the following pricing methods provides a way to determine the lowest cost to the customer in a competitive

More information

IBM Power Systems. IBM Systems and Technology Group. Power your planet. Smarter systems for a smarter planet

IBM Power Systems. IBM Systems and Technology Group. Power your planet. Smarter systems for a smarter planet IBM Systems and Technology Group IBM Power Systems Power your planet Smarter systems for a smarter planet 2 Power your planet Minimizing complexity, improving efficiency, and scaling easily These are the

More information

IBM System i Model 515 offers new levels of price performance

IBM System i Model 515 offers new levels of price performance IBM Europe Announcement ZG07-0267, dated April 10, 2007 IBM System i Model 515 offers new levels of price performance Description...2 Product positioning... 7 At a glance System i model 515 Express Configurations

More information

IBM Exam A Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ]

IBM Exam A Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ] s@lm@n IBM Exam A4040-101 Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ] IBM A4040-101 : Practice Test Question No : 1 Which of the following IOS commands displays

More information

Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2

Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2 Vendor: IBM Exam Code: A4040-122 Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2 Version: Demo Topic 1, Volume A Question No : 1 - (Topic 1) A customer needs 2 Power Systems servers,

More information

IBM Power Systems Update. David Spurway IBM Power Systems Product Manager STG, UK and Ireland

IBM Power Systems Update. David Spurway IBM Power Systems Product Manager STG, UK and Ireland IBM Power Systems Update David Spurway IBM Power Systems Product Manager STG, UK and Ireland Would you like to go fast? Go faster - win your race Doing More LESS With Power 8 POWER8 is the fastest around

More information

IBM Power Systems. 14 February IBM Power Systems Facts and Features: Enterprise and Scale-out Systems with POWER8Ò Processor Technology

IBM Power Systems. 14 February IBM Power Systems Facts and Features: Enterprise and Scale-out Systems with POWER8Ò Processor Technology 14 February 2017 IBM Systems Facts and Features: Enterprise and Scale-out Systems with POWER8Ò Processor Technology 1 Table of contents Page no. Notes 3 Why Systems 4 IBM System S812LC, S822LC for Commercial

More information

POWER Block Course Assignment 2: System Management. Hasso-Plattner Institute

POWER Block Course Assignment 2: System Management. Hasso-Plattner Institute POWER Block Course Assignment 2: System Management Hasso-Plattner Institute Agenda 1. General Information 2. Assignment 2 System Management 3. Helpful Links / Troubleshooting Assignment 2 System management

More information

IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment

IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment This document can be found in the IBM Techdocs library, www.ibm.com/support/techdocs

More information

IBM Europe Announcement ZG , dated February 13, 2007

IBM Europe Announcement ZG , dated February 13, 2007 IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and

More information

PowerVM Single Root I/O Virtualization: Fundamentals, Configuration, and Advanced Topics

PowerVM Single Root I/O Virtualization: Fundamentals, Configuration, and Advanced Topics PowerVM Single Root I/O Virtualization: Fundamentals, Configuration, and Advanced Topics Allyn Walsh Consulting IT Specialist awalsh@us.ibm.com Many contributions from Chuck Graham STSM, Lead Architect

More information

Microsoft Office SharePoint Server 2007

Microsoft Office SharePoint Server 2007 Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC

More information

Exam Questions C

Exam Questions C Exam Questions C9010-250 Power Systems with POWER8 Sales Skills V1 1. A credit card company is going to implement a new application for which security is a major requirement. The company has been quoted

More information

Veritas InfoScale 7.0 Virtualization Guide - AIX

Veritas InfoScale 7.0 Virtualization Guide - AIX Veritas InfoScale 7.0 Virtualization Guide - AIX November 2015 Veritas InfoScale 7.0 Virtualization Guide The software described in this book is furnished under a license agreement and may be used only

More information

SAN Storage Array Workbook September 11, 2012

SAN Storage Array Workbook September 11, 2012 Page 1 of 9 The following are questions to be asked regarding acquiring SAN Storage Arrays. Some of the questions need to be filled in for the specific environment where the storage system will be deployed

More information

IBM PureFlex Technical

IBM PureFlex Technical IBM PureFlex Technical Number: 000-783 Passing Score: 660 Time Limit: 90 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which of the following virtualization products is required to

More information

VMware vsphere with ESX 4.1 and vcenter 4.1

VMware vsphere with ESX 4.1 and vcenter 4.1 QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.

More information

IBM Enterprise Technical Support for AIX and Linux -v2. Download Full Version :

IBM Enterprise Technical Support for AIX and Linux -v2. Download Full Version : IBM 000-108 Enterprise Technical Support for AIX and Linux -v2 Download Full Version : http://killexams.com/pass4sure/exam-detail/000-108 QUESTION: 117 An administrator is preparing fibre-channel attached

More information

IBM Power 520 and 550 Express offer faster processor options and popular, easy-to-order configurations

IBM Power 520 and 550 Express offer faster processor options and popular, easy-to-order configurations , dated April 28, 2009 IBM Power 520 and 550 Express offer faster processor options and popular, easy-to-order configurations Table of contents 1 At a glance 19 Publications 1 Overview 20 Services 2 Key

More information

IBM System x3850 M2 servers feature hypervisor capability

IBM System x3850 M2 servers feature hypervisor capability IBM Europe Announcement ZG08-0161, dated March 25, 2008 IBM System x3850 M2 servers feature hypervisor capability Key prerequisites...2 Description...3 Product positioning... 7 Reference information...

More information

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage Database Solutions Engineering By Raghunatha M, Ravi Ramappa Dell Product Group October 2009 Executive Summary

More information

IBM Power Systems Express Servers

IBM Power Systems Express Servers Mid-sized businesses are the engines of a Smarter Planet IBM Power Systems Servers companies. With a range of options from blades, 2-U, 4-U rack and tower systems, IBM Power Systems servers provide the

More information

IBM System p5 505 and System p5 505Q offer four new processor options

IBM System p5 505 and System p5 505Q offer four new processor options Hardware Announcement July 25, 2006 IBM System p5 505 and System p5 505Q offer four new processor options Overview The System p5 505 offers new POWER5+ processor options with the 1-core, 1.9 GHz processor

More information