1 FREQUENCY CONVERTER FC101 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction of rotation 4 More information 4 Wiring diagram 5 Basic configuration 6 PID regulation 7

2 2 Installation and maintenance SAFETY INSTRUCTIONS Check that the frequency converter is correctly connected to earth. Do not pull out the mains or motor contacts or other power connections when the frequency converter is connected to the power supply grid. Protect the user from mains voltage. Protect the motor against overload in accordance with national and local regulations. The leakage currents to earth exceed 3.5 ma, see the Design guide on the enclosed CD. The [Off/Reset] button is not an isolator switch. It does not disconnect the frequency converter from the mains. WARNING! Warning high voltage The frequency converter is subject to highly dangerous voltages when it is connected to the mains. Incorrect installation of the motor or frequency converter can lead to material damage, serious personal injury or death. Follow the instructions in this manual as well as local and national provisions and safety regulations. Voltage (V) WARNING! Discharge time! Frequency converters have DC bus capacitors that can hold a charge even after the mains voltage has been disconnected. Prevent electrical hazards by disconnecting the mains voltage, disconnecting permanent magnet motors and DC bus supplies, including battery backup, UPS and DC bus connections for other frequency converters. Wait until the capacitors have fully discharged before carrying out maintenance or repairs. Read more about the discharge waiting times in the table below. Starting to service or repair the unit immediately after cutting the power supply, without waiting for the specified period, can lead to death or serious personal injury. Output range (kw) Minimum waiting time (min) 3 x 200 0, x x 400 0, x WARNING! Installation at heights For installation at height, contact FläktGroup regarding PELV. TAKE CARE! Residual current device: This product can cause a direct current in the protective earth conductor. When using a residual current device as additional protection, use only a type B residual current device (delayed) on the input side of this product. See also Danfoss application note for the MN90G RCD. The protective earthing of the frequency converter and the use of RCDs must always follow national and local regulations. TAKE CARE! IT system (3x230VAC) When installing the FC101 on an isolated system (IT system, 3x230VAC) set parameter to [0] Off. Press [Main Menu] twice. Navigate using the [ ] [ ] and [OK] buttons until parameter is displayed (select 14 **, then 14 5* and lastly 14 50). Set this parameter to [0] Off.

3 Installation and maintenance 3 For kW the RFI switch must be opened by removing the screw (1) on the side of the frequency converter before energising it. See figure beside. CONNECTIONS DIAGRAM RS Supply 3 Protective earth 4 Cable clamps 5 Motor 6 UDC (not in use) 7 7 Relay outputs 8 I/O 6 5 4

4 4 Installation and maintenance CONTROL UNIT (LCP) A. Alphanumeric display 1. Parameter number and name. 2. Parameter value 3. Menu number 4. Direction of rotation of the motor 5. Triangle labelling of the status menu, quick menu or main menu A B Com Motor Power [5] 0.37kW - 0.5HP Setup 1 Menu Status Quick Menu Main Menu 130BB B. Menu buttons Menu button for selecting the status menu, quick menu or main menu. C. Navigation and indication 6. LED Com: Data traffic over the bus 7. LED On (green): Control unit in operation 8. LED Warn. (yellow): Warning indication. 9. LED Alarm (red): Alarm indication. 10. [Back]: Returns to the previous step or level [ ] [ ] [ ]: Navigation between parameters and for changing parameters or local references. 12. [OK]: Selecting parameters and saving set values C D On Warn. Alarm Hand On Back OK Off Reset Auto On D. Control buttons with LEDs 13. [Hand/On]: Starting the motor for local control using the control unit 14. [Off/Reset]: Stopping the motor and resetting alarms. 15. [Auto/On]: Allow control via control terminals or the communication bus MANUAL OPERATION Press [Hand/ON] to start Press [ ] [ ] to set the speed Press [OFF/Reset] to stop Press [Auto/ON] to return to automatic operation REVERSE THE DIRECTION OF ROTATION If necessary the direction of rotation can be reversed using parameter When connection is correct 0 = clockwise and 1 = anti-clockwise. MORE INFORMATION This quick guide contains the basic information needed to install and operate the frequency converter. There is more information available on the enclosed CD.

5 Installation and maintenance 5 WIRING DIAGRAM L1 L2 L3 N PE F L1 L2 L3 PE U V W PE Danfoss FC V V 13 DIG IN 18 DIG IN 19 COM 20 DIG IN 27 DIG IN 29 DIG IN 32 DIG IN 33 DIG IN V 50 A IN 53 A IN 54 COM 55 A OUT 42 COM 39 R2 R RS-485 com 61 RS RS Relay output 0 Alarm NO/NC (Param ) Relay output 1 Start Start Reference 0 10VDC (FW standard) Actual value PID regulation Run Indicator NO/NC (Param ) M The basic configuration (FläktGroup standard) relates to VDC control via terminal block 53. To activate the internal PID regulator see page 6. The sensor is connected to terminal block 54. SIGNALS Designation Type Terminal block Start Potential-free closure Control signal VDC 53 Pressure/flow sensor VDC (4...20mA) 54 COM For analogue in (Terminal blocks 53, 54) 55 Alarm R1 NO/NC 01, 02, 03 Operation R2 NO/NC 04, 05, 06

6 6 Installation and maintenance BASIC CONFIGURATION FOR ASYNCHRONOUS MACHINES (FLÄKTGROUP STANDARD) When the frequency converter is energized for the first time the language can be selected. Obviously this can be changed later. After the configuration guide (FC101 Wizard) is started for VDC control by pressing [OK] again. If you intend instead to use the internal PID regulator, press [Back] and continue to the next page in the quick guide. Step Parameter Description TF FF 6-15** T53 High Ref./Feedb. Value Same as 3-03 Same as Language English English Regional settings International International GridType V/50 Hz/IT-grid V/50 Hz Motor construction Asynchron Asynchron See order Motor Power [kw] Motor Voltage [V] Motor frequency [Hz] Motor current [A] See motor plate Motor nominal speed [rpm] Motor cable length 50m 50m Motor speed low limit 0 Hz 0 Hz **) Motor speed high limit Same as 3-03 Same as Ramp 1 ramp-up time Ramp 1 ramp-down time Flying start Enable Enable 30s 40s T53 Mode Voltage Voltage T53 Low voltage 0.07 V 0.07 V T53 High voltage 10 V 10 V Min reference 0 Hz 0 Hz Max reference Hz Hz Function of relay 1 Alarm Alarm Function of relay 2 Drive running Drive running do not change do not change Automatic motor adaptation Enable Enable Complete Complete AMA AMA **) If the Motor speed high limit is to be set higher than 50 Hz then 6-15 must first be changed to the same value from the Main menu. If the Motor speed high limit is to be set higher than 100 Hz then 4-19 and 6-15 must first be changed to the same value from the Main menu. When using CentriFlow 3D, you need to enter 1-06 and change the direction of rotation to [1] inverse. Configuration carried out by Date The configuration guide can be reactivated at any time. Press [Menu] until the indicator in the display points to Quick menu. Start the configuration guide (FC101 Wizard) by pressing [OK]. Danfoss factory reset Press [Menu] until the arrow points to Main menu. Navigate using the [ ] [ ] buttons and [OK] until the parameter is displayed (select 14-**, then 14-2* and lastly 14-22). Set this parameter to 2 and then switch off the mains voltage. When the frequency converter is re-energised the parameters will have returned to their factory settings and alarm 080 is generated. Press [Off/Reset] to acknowledge this.

7 Installation and maintenance 7 PID REGULATION OF ASYNCHRONOUS MACHINES To configure the frequency converter for operation using the internal PID regulator press [Menu] until the indicator in the display points to Quick menu. Press the [ ] [ ] buttons to select Close loop setup. Then start the configuration guide for PID regulation by pressing [OK]. Step Parameter Description TF FF Regional settings International International GridType V/50 Hz/IT-grid V/50 Hz Configuration mode Closed loop Closed loop Motor construction Asynchron Asynchron Motor Power [kw] Motor Voltage [V] Motor frequency [Hz] See motor plate Motor current [A] Motor nominal speed [rpm] Motor speed low limit 0 Hz 0 Hz **) Motor speed high limit Hz Hz Ramp 1 ramp-up time Ramp 1 ramp-down time 30s 40s Flying start Enable Enable Min reference 0 % 0 % Max reference % % Preset reference % % Terminal 54 mode (Voltage/Current) (6-22)* T54 low voltage [V] (Current [A])* 0.07V/4mA 0.07 V/4mA Setpoint See sensor T54 low feedback [%] 0 % 0 % (6-23)* T54 high voltage [V] (Current [A])* 10V/20mA 10V/20mA T54 high feedback [%] 100 % 100 % T54 Filter time constant 1 s 1 s PI Normal/Inverse control Normal Normal PI Start speed [Hz] 0 Hz 0 Hz PI Proportional gain PI Integration time [s] 30 s 30 s Adjust if necessary Automatic motor adaptation Enable Enable complete complete *) The parameter in question in the Quick menu depends on the function selected using the parameter **) If the Motor speed high limit is to be set higher than 50 Hz then 3-03 and 6-15 must first be changed to the same value from the Main menu. If the Motor speed high limit is to be set higher than 65 Hz then 4-19, 3-03 and 6-15 must first be changed to the same value from the Main menu. AMA AMA Configuration carried out by Date

8 8 Installation and maintenance MODBUS RTU IN EQ If Modbus RTU is used in eq AHU for controlling drives, they must be set according to the table below. Configuration Parameter Description Value 8-30 Protocol [2] Modbus RTU 8-31 Address Supply fan: 60 Exhaust fan: Baudrate [2] Parity / Stop bits [2] No parity, 1 Stop bit PARALLEL OPERATION When two frequency converters are to operate in parallel, one must be configured as master and the other as slave. After this, connect the two frequency converters together as indicated below. Configuration, master Parameter Description TF FF 6-70 Signal terminal block mA 4-20mA 6-71 Function, terminal block 45 Reference Reference Configuration, slave Parameter Description TF FF 6-19 Selection of reference signal ma ma 6-14 Output frequency equivalent to 4mA 0 Hz 0 Hz 6-15 Output frequency equivalent to 20mA Hz Hz Connection Master Slave

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

FREQUENCY CONVERTER FC102 (QUICK GUIDE) FREQUENCY CONVERTER FC102 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction

More information

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW. CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS

More information

User Guide VLT Parallel Drive Modules

User Guide VLT Parallel Drive Modules ENGINEERING TOMORROW User Guide VLT Parallel Drive Modules 250 1200 kw vlt-drives.danfoss.com Contents User Guide Contents 1 Introduction 4 1.1 Purpose of the Manual 4 1.2 Additional Resources 4 1.3 Manual

More information

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Safety Instructions 1-1 Avoid unintended Start General Description 2-2 Contents Contents 1 Safety and precautions 1-1 Safety Instructions 1-1 Avoid unintended Start. 1-1 2 Introduction 2-1 General Description 2-2 3 Supported Configuration 3-1 Introduction 3-1 Fixed-speed

More information

Operating Instructions Extended Cascade Controller MCO 101

Operating Instructions Extended Cascade Controller MCO 101 Operating Instructions Extended Cascade Controller MCO 101 VLT AQUA Drive FC 200 Extended Cascade Controller Option Contents Contents 1. Safety and precautions 3 Safety Instructions 3 Avoid unintended

More information

1 Extended and Advanced Cascade Controller Option 3

1 Extended and Advanced Cascade Controller Option 3 VLT Operating Instructions Contents Contents Extended and Advanced Cascade Controller 3 How to read these Operating Instructions 3 High Voltage Warning 3 Safety Instructions 3 Avoid unintended Start 3

More information

MAKING MODERN LIVING POSSIBLE. Quick Guide. VLT HVAC Basic Drive Cascade Control *MG18F102*

MAKING MODERN LIVING POSSIBLE.   Quick Guide. VLT HVAC Basic Drive Cascade Control *MG18F102* MAKING MODERN LIVING POSSIBLE www.danfoss.com/drives Quick Guide VLT HVAC Basic Drive Cascade Control 30R0265 MG8F02 *MG8F02* Rev. 20-03-22 Contents Contents Quick Guide 2. Safety 2.. Warnings 2..2 Safety

More information

Vacon HVAC100 Commissioning Guide

Vacon HVAC100 Commissioning Guide Vacon HVAC100 Commissioning Guide INDEX 1. Glossary of terms 2. Wiring diagrams 3. Set up procedures a. Motor settings input b. Low level start, analogue input speed reference in AUTO position. Low level

More information

MAKING MODERN LIVING POSSIBLE. Quick Guide VLT HVAC Basic Drive

MAKING MODERN LIVING POSSIBLE. Quick Guide VLT HVAC Basic Drive MAKING MODERN LIVING POSSIBLE Quick Guide VLT HVAC Basic Drive Contents Contents Quick Guide 2. Safety 2.. Warnings 2..2 Safety Instructions 2.2 Introduction 2.2. Available Literature 2.2.2 Approvals 2.2.3

More information

AF-60 LP TM Micro Drive. Programming Guide

AF-60 LP TM Micro Drive. Programming Guide GE AF-60 LP TM Micro Drive Programming Guide Contents Contents 1 Safety 1-1 1.1.1 High Voltage Warning 1-1 1.1.2 Safety Instructions 1-1 1.1.3 Software Version and Approvals 1-1 1.1.4 General Warning 1-1

More information

MAKING MODERN LIVING POSSIBLE. VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions

MAKING MODERN LIVING POSSIBLE. VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions MAKING MODERN LIVING POSSIBLE VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions Safety VLT AQUA Drive MCO 101/MCO 102 Safety WARNING HIGH VOLTAGE Frequency converters contain

More information

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions GE AF-600 FP TM Fan & Pump Drive (230V to 60HP, 460/575V to 125HP Operating Instructions Safety Safety WARNING HIGH VOLTAGE! Frequency converters contain high voltage when connected to AC mains input power.

More information

Taco System Logic (TSL)

Taco System Logic (TSL) Taco System Logic (TSL) 302-370 Installation, Operation, and Maintenance Manual SUPERSEDES: June 27, 2014 EFFECTIVE: December 21, 2015 Table of Contents 1 ELECTRICAL CONNECTIONS................. 2 1.1

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

MAKING MODERN LIVING POSSIBLE. Instruction VLT HVAC Basic Drive Cascade Controller

MAKING MODERN LIVING POSSIBLE. Instruction VLT HVAC Basic Drive Cascade Controller MAKING MODERN LIVING POSSIBLE Instruction VLT HVAC Basic Drive Cascade Controller 1.1 Cascade Controller Constant Speed Pumps (2) Variable Speed Pumps (1) Motor starter Illustration 1.1 Cascade Controller

More information

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B Metasys N2 Instruction Manual VLT 6000 Adjustable Frequency Drive 12/99-6110-00 Revision B 2 Table of Contents Overview Page Introduction... 5 About this Manual... 5 References... 5 Instructions Abbreviations

More information

Installation Instructions

Installation Instructions Installation Instructions Variable Frequency Drive (VFD) 7 ½ - 25 Ton Units with 2 Wire Control WARNING UNINTENDED EQUIPMENT OPERATION Modifying or changing parame eters whose function is not described

More information

Control system for rotary heat exchanger EQRB, L=3,4

Control system for rotary heat exchanger EQRB, L=3,4 Installation instructions, drive system EQRB, L=3.4 sizes 005-072 General description A speed controlled drive system specifically adapted to drive rotary heat exchangers. No tuning is necessary. All control

More information

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3) These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar

More information

P216 Series Condenser Fan Speed Controller

P216 Series Condenser Fan Speed Controller P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

Operating Instructions

Operating Instructions Operating Instructions VLT Micro Drive FC 51 VLT Micro Drive FC 51 Operating Instructions Contents Contents 1. Safety 5 Safety Instructions 5 Approvals 5 General Warning 5 Avoid unintended Start 6 Before

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Installation and Wiring Instructions... 9

Installation and Wiring Instructions... 9 Contents Safety and precautions... 3 Safety regulations... 4 Warning against unintended start... 4 Operation modes... 6 Cascade Control Operation... 6 Standard Cascade Control Mode... 7 Lead Pump Alternation...

More information

Genset control and protection with safety system

Genset control and protection with safety system APPLICATION NOTES Generator Protection Unit, GPU-3 APPLICATION NOTES Genset control and protection with safety system Application description Functional description Wiring I/O lists Basic setup Flowcharts

More information

Operating Instructions

Operating Instructions MAKING MODERN LIVING POSSIBLE Operating Instructions VLT DriveMotor FCP 106 and FCM 106 Metasys N2 www.danfoss.com/drives Contents Contents 1 Introduction 2 1.1 Purpose of the Manual 2 1.2 Additional

More information

TR150 DRIVE STANDARD FEATURES

TR150 DRIVE STANDARD FEATURES TR150 DRIVE STANDARD FEATURES The TR150 Drive The TR150 Drive Series is a microprocessor-based, high frequency IGBT-based, PWM AC drive with control functions and software designed solely for the unique

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

EQ5 SERIES Quick Start Guide for Constant Torque Applications

EQ5 SERIES Quick Start Guide for Constant Torque Applications EQ5 SERIES Quick Start Guide for Constant Torque Applications PN EQ5QSCT, Revision: 0.02, April 4 th 2009 EQ5 Drive Quick Start Guide for Constant Torque Applications Contents Page Introduction... 3 1.

More information

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus 4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output

More information

NICOTRA Gebhardt EKE E-IM EKE E-IM S. Operating manual EC-Controller BA-EKE /2012

NICOTRA Gebhardt EKE E-IM EKE E-IM S. Operating manual EC-Controller BA-EKE /2012 Operating manual EC-Controller EN BA-EKE 2.04 01/2012 EKE 07-0065-5E-IM EKE 07-0065-5E-IM S Warning Before installing and commissioning the EC-Controller, you must read all safety instructions and warnings

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

TPE, TPED Series 2000

TPE, TPED Series 2000 GRUNDFOS INSTRUCTIONS TPE, TPED Series 2000 Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Standard Cascade Controller Setup... 38

Standard Cascade Controller Setup... 38 Contents Safety and precautions... 3 Safety regulations... 4 Warning against unintended start... 4 Operation modes... 6 Cascade Control Operation... 6 Standard Cascade Control Mode... 7 Master/Slave Cascade

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

WARNING ELECTRICAL SHOCK HAZARD

WARNING ELECTRICAL SHOCK HAZARD Description Safety Instructions The top-entry sub D9 connector kit is designed for enclosure sizes D1h D8h, E1 E2, and E1h E4h with VLT PROFIBUS DP MCA 101 option. It fits the following drives: VLT HVAC

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Unidrive M400 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M400 User Guide which is

More information

Control D. Controller Module for Proportional Valve Control. Installation Manual

Control D. Controller Module for Proportional Valve Control. Installation Manual Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. Please refer to the Unidrive M200 / M20 User Guide which is available to download from www.controltechniques.com/user

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

Voltsys Inverter Control Unit

Voltsys Inverter Control Unit Voltsys Inverter Control Unit Coomanore North, Bantry, info@voltsys.com Co. Cork. Republic of Ireland tel. +353 (0) 27 52773 Contents Important Safety Instructions... 3 Controller Layout & Wiring... 4

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3 QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3 What's in the delivery? Getting started The first steps PC

More information

Modbus RTU Option Card for VLT 5000/6000 Adjustable Frequency Drive

Modbus RTU Option Card for VLT 5000/6000 Adjustable Frequency Drive Modbus RTU Option Card for VLT 5000/6000 Adjustable Frequency Drive VLT is a registered Danfoss trade mark MG.10.P2.22 1 Rotating shafts and electrical equipment can be hazardous. Perform all electrical

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Genset Controller Unit Model EMS - GC10. Installation Manual Section Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 2.00 Optidrive P2 Advanced User Guide Rev 2.00 Optidrive P2 Parameter Set Overview 1 This Document

More information

Installation Guide VLT Programmable I/O MCB 115

Installation Guide VLT Programmable I/O MCB 115 MAKING MODERN LIVING POSSIBLE Installation Guide VLT Programmable I/O MCB 115 VLT AutomationDrive FC 302 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 2 1.1 Purpose of the

More information

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD lnvertek Drives.com ft ct,ve ELECTRICAL SUPPLIERS LTD OptidriveE2 Technical Product Guide 1.1 OVERVIEW Range IP20 IP66X (NON SWITCHED) IP66Y (SWITCHED) Supply Voltage Range Power Range 110 115 + / 10%

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

AF-60 LP TM Micro Drive

AF-60 LP TM Micro Drive GE Consumer & Industrial Electrical Distribution AF-60 LP TM Micro Drive Operating Instructions Contents 1 Safety 5 Safety Instructions 5 Software Version and Approvals 6 General Warning 7 Avoid unintended

More information

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs QUICK START GUIDE Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

Tachometer Panel, PE3

Tachometer Panel, PE3 Features Plug-n-play units with factory programmed parameters 4-20 ma feedback signal Isolated relay alarm outputs Frequency input Diagnostic indicators NEMA 4 Enclosure Model PE3, Tachometer Panel Benefits

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 1.10 Optidrive P2 Parameter Set Overview 1 This Document is for use with version 1.20 Firmware. Advanced

More information

Q9 ASD LOW VOLTAGE DRIVE

Q9 ASD LOW VOLTAGE DRIVE ASD LOW VOLTAGE DRIVE HVAC-MINDED, SYSTEM FRIENDLY RELIABLE Toshiba has manufactured pulse-width modulated drives since 1981 and is one of the few companies that manufactures both motors and drives in

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL

INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL Before installing or starting this unit for the first time, this manual should be studied carefully to obtain a working

More information

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO L510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

DC / AC True RMS Watt Clamp DMM

DC / AC True RMS Watt Clamp DMM 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 380940 Product Page DC / AC True RMS Watt Clamp DMM 10W or 100mA

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions Brief Instructions PumpDrive 4070.801/2--11 Self -cooling, motor-independent frequency inverter Mounting variants: Motor mounting (MM) Wall mounting (WM) Cabinet mounting (CM) Brief Instructions 1 About

More information

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying

More information

Compressor Controller MAM 890

Compressor Controller MAM 890 Compressor Controller MAM 890 OPERATION MANUAL Revision 1.0 04.08.2017 Notice Please read all the operation manual before operating the set and keep this manual for further reference. Installation of MAM

More information

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY Technical Manual HA09 Issue 008 Parker SSD Drives, a division of Parker Hannifin Ltd. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form

More information

Peristaltic Cased Tube Pump

Peristaltic Cased Tube Pump Peristaltic Cased Tube Pump Selectable Output Control Functionality and Setup Version 1.0v-11/2016 Print-No. 01 Table of Contents 1. Introduction 2. Powering the Input/Output Port 2.1 Wiring for Local

More information

Altivar 21 Programming and Operation Guide

Altivar 21 Programming and Operation Guide Altivar 21 Programming and Operation Guide Instruction Bulletin 372-451-63 Retain for future use. 372-451-63 Altivar 21 Programming and Operation Guide 3/27 Table of Contents Hazard Categories and Special

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Instruction Manual. Modbus RTU VLT 5000 VLT 6000 HVAC

Instruction Manual. Modbus RTU VLT 5000 VLT 6000 HVAC Instruction Manual Modbus RTU VLT 5000 VLT 6000 HVAC Modbus RTU Option Card VLT 6000 Adjustable Frequency Drive Instruction Manual 23-6130-00 Revision B 02/03 Rotating shafts and electrical equipment can

More information

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODE-3-038 Related Products Optidrive E3 Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience

More information

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0.

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0. 1 Quick Start Up User Guide IP20 & IP66 (NEMA 4X) AC Variable Speed Drive 0.37 22kW (0.5 30HP) 110 480V Installation and Operating Instructions 1 Quick Start Up 1 1. Quick Start Up... 4 1.1. Important

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

Optidrive VTC Modbus RTU Register Map

Optidrive VTC Modbus RTU Register Map Application Note AN-VTC- 39 Optidrive VTC Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 6 September 2006 General This document details the Modbus RTU memory mapping implemented

More information

1. Safety Danger Warnings Earthing and earth fault protection... 4

1. Safety Danger Warnings Earthing and earth fault protection... 4 vacon 1 INDEX Document: DPD00386A Version release date: 24.9.10 1. Safety... 2 1.1 Danger... 2 1.2 Warnings... 3 1.3 Earthing and earth fault protection... 4 2. Metasys N2 - general info... 5 3. N2 technical

More information

CURRENT PROTECTION RELAY SMPR-1

CURRENT PROTECTION RELAY SMPR-1 CURRENT PROTECTION RELAY SMPR-1 1.- ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this protocol

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

300XAC. Quick Start Guide. Modular AC Power Source MODELS 310XAC, 320XAC, 340XAC, 360XAC

300XAC. Quick Start Guide. Modular AC Power Source MODELS 310XAC, 320XAC, 340XAC, 360XAC 00XAC Quick Start Guide Modular AC Power Source MODELS 0XAC, 0XAC, 40XAC, 60XAC POWER CHECKLIST Power down output while connections are made. Output & input cabling have unique AWG carrying capacity. (Be

More information

DeviceNet Drive Profile CFW-09

DeviceNet Drive Profile CFW-09 Motors Automation Energy Transmission & Distribution Coatings DeviceNet Drive Profile CFW09 Communication Manual DeviceNet Drive Profile Communication Manual Serie: CFW09 Language: English Software Version:

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

Instruc on Manual. Series S3. Industrial Inverter IP20 IP66

Instruc on Manual. Series S3. Industrial Inverter IP20 IP66 Instruc on Manual Industrial Inverter Series S3 IP20 IP66 1. Quick Start Up... 4 1.1. Important Safety Information 4 1.2. Quick Start Process 5 1.3 Installation Following a Period of Staorage 5 1.4. Quick

More information

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC QUICK START GUIDE Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version: MULTI-LINE 2 APPLICATION NOTES Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com

More information

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95 Part 1 - GENERAL ASEA BROWN BOVERI ABB Industrial Systems Inc. Standard Drives ACH500-06E Effective 6/1/95 Sample Specification for Adjustable Frequency Drives (2 to 400 HP) for Variable Torque Applications

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

VLT Micro Drive. Ready Set Go!

VLT Micro Drive. Ready Set Go! Despite its compact size and ease of installation, the VLT Micro Drive can deliver exceptional performance even in complex applications. 1 Well protected IP20 enclosure with NEMA/UL Type 1 optional; no

More information

Voltsys Inverter Control Unit

Voltsys Inverter Control Unit Voltsys Inverter Control Unit Coomanore North, Bantry, info@voltsys.com Co. Cork. Republic of Ireland tel. +353 (0) 27 52773 Contents Important Safety Instructions... 3 Controller Layout & Wiring... 4

More information

VLT 8000 AQUA. Installation. Mechanical installation

VLT 8000 AQUA. Installation. Mechanical installation Mechanical installation Please pay attention to the requirements that apply to integration and field mounting kit, see the below list. The information given in the list must be observed to avoid serious

More information

AC Variable Speed Drive

AC Variable Speed Drive User Manual AC Variable Speed Drive IP20 & IP66 (NEMA 4X) 0.37kW 22kW / 0.5HP 30HP 110 480V 3 Phase Input Troubleshooting 0 Quick Start Up General Information and Ratings Mechanical Installation Power

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual Item Number 125-3201, Rev. 012 SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual NOTICE The information

More information