Time Delay Values (E-Series)
|
|
- Imogen Paul
- 5 years ago
- Views:
Transcription
1 Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO DC D.C. INSTANTANEOUS CURVE NO Short SHORT DELAY CURVE NO D.C. SHORT DELAY CURVE NO Medium 00 0 MEDIUM DELAY CURVE NO D.C. MEDIUM DELAY CURVE NO Long LG DELAY CURVE NO D.C. LG DELAY CURVE NO DELAY % 25% 50% 200% 400% % 800% 0% 200% TRIP 0 NO TRIP MAY TRIP 2 NO TRIP TIME 4 NO TRIP NO TRIP (SECDS) 20 NO TRIP MAY TRIP 22 NO TRIP NO TRIP NO TRIP Delay Curves 0,20: Breakers to hold % and must trip at 50% of rated current and greater within the time limit shown in these curves. Delay Curves 2,4,6,24,26: Breakers to hold % and must trip at 25% of rated current and greater within the time limit shown in these curves. All Curves: Curve data shown represents breaker response at ambient temperature of 77 F (25 C) with no preloading. Breakers are mounted in standard wallmount position. The minimum inrush pulse tolerance handling capability on the above standard delays is 6 times rated current on a 60 Hz /2 cycle, 8 ms pulse. 4 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
2 ESeries ESeries Handle Actuator Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for stranded wire. Power selector device available, consult factory. The ESeries is UL LISTED and CSA Certified for Branch Circuit protection which does not require a fuse backup. It is also UL Recognized and CSA Certified as a Supplementary Protector and as a Manual Motor Controller. 6 poles,. amps, up to VAC or 25 VDC, with choice of time delays and actuator colors. UL UL CSA Agency Approvals UL LISTED Circuit Breaker, Guide DIVQ, File E29899, under UL Standard 489. UL Recognized under the Component Recognition Program as: Protectors, Supplementary (Guide QVNU2, File E75596), UL Standard 077; Industrial Control Equipment Motor Controllers, Manual (Guide NLRV2, File E35367), UL Standard 508; Marine Electrical and Fuel Systems (Guide PEQZ2, File E 75596) UL Standard 500 (Ignition Protection). CSA Certified Circuit Breaker, Class 432 0, File LR9390, under CSA Standard C22.2 No. 5. CSA Certified Supplementary Protectors, Class 325 0, File LR47848 under Standard C22.2 No In compliance with Publications IEC , 950, EN and VDE 0805 with regard to 8mm reinforced spacing. General Specifications ELECTRICAL Table A: Lists UL LISTED (489), CSA Certified (C22.2 No. 5) configurations and performance capabilities as a Molded Case Circuit Breaker and UL Recognized (077), CSA Certified, (C22.2 No. 235) configurations and performance capabilities as a Component Supplementary Protector. CIRCUIT CFIGURATI AS A LISTED (UL 489) BRANCH CIRCUIT PROTECTOR VOLTAGE MAX VOLTAGE FREQUENCY PHASE FULL LOAD AMPS CURRENT INTERRUPTING CAPACITY Series 25 20/ DC 50/60Hz 50/60Hz Ø & 3Ø 5000 A Res A.45 P.F A.45 P.F. AS A UL RECOGNIZED (077/508) SUPPLEMENTARY PROTECTOR/ MANUAL MOTOR CTROLLER AND CSA CERTIFIED SUPPLEMENTARY PROTECTOR VOLTAGE CURRENT INTERRUPTING CAPACITY CIRCUIT CFIGURATI Series and Shunt Switch Only MAX VOLTAGE FREQUENCY PHASE 25 20/ D.C. 50/60Hz D.C. 50/60Hz Ø & 3Ø Ø Ø & 3Ø & 3Ø & 3Ø Ø & 3Ø & 3Ø FULL LOAD AMPS with backup fuse I.C. 0,000 A 0,000 A 0,000 A Max. Fuse 225 A 225 A 225 A w/o backup fuse I.C. 5,000 A 5,000 A 5,000 A 5,000 A * Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 5A minimum and no more than 4 times the full load amps maximum, not to exceed 225A.. All circuit breakers are labeled with the maximum UL LISTED/Recognized and CSA Certified voltages V and V ratings require 3 or 4 pole 3Ø and 2 pole break Ø. In addition, an insulating barrier of vulcanized fibre or equivalent is required between the breaker and the front panel. Request drawing #PR for specifications. 86 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
3 General Specifications (cont.) Maximum Voltage VAC, 25VDC (See Table A) Current Ratings Standard current coils: 0., 0.250, 0.500,.00, 2.50, 5.00, 7.50, 0.0, 5.0, 20.0, 25.0, 30.0, Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance 50.0, 60.0, 70.0 & Amp. SPDT; 0. AMPS 250VAC, 5.0 AMPS30VDC, 0. Amps 25VAC (with gold contacts). Minimum of Megohms at 500 VDC. UL, CSA: 2200 V for one minute between all electrically isolated terminals. ESeries Circuit Breakers comply with the 8mm spacing and 3750V dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications IEC 380, 435, 950, EN and VDE Values from Line to Load Terminal based on Series Trrip Circuit BReaker ESeries 0 0 CURRENT (AMPS) TOLERANCE (%) ± ± ±35 O H M S AMPERE RATING MECHANICAL Endurance Trip Free Trip Indication ENVIRMENTAL Environmental Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature 0,000 OFF 6 per minute; with rated Current and Voltage. All ESeries Circuit Breakers will trip on overload, even when Handle is forcibly held in the position. The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Designed and tested in accordance with requirements of specification MILC and MIL STD202 as follows: Withstands Gs, 6ms, sawtooth while carrying rated current per Method 23, Test Condition I. Withstands 0.060" excursion from 055 Hz, and 0 Gs Hz, at rated current per Method 204C, Test Condition A. Method 06D, i.e., ten 24hour + 25 C to +65 C, 8098% RH. Method 0, Condition A (9095% 5% NaCl Solution, 96 hrs). Method 07D, Condition A (Five 55 C to +25 C to +85 C to +25 C). 40 C to +85 C PHYSICAL Number of Poles 6 Mounting A 3" minimum spacing must be provided between the circuit breaker arc venting area on back connected ESeries circuit breakers and grounded obstructions. ESeries circuit breakers must be mounted on a vertical surface. Connectors, Box Type Front connected ESeries circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: /04 Copper, /02 Aluminum Internal Circuit Configurations Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Weight Approximately 252 grams/pole (Approximately 9 ounces/pole) Standard Colors HousingBlack; Actuator See Ordering Scheme. Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
4 ESeries Circuit and Terminal Diagrams SERIES TRIP (2 TERMINALS) SWITCH LY (2 TERMINALS) SERIES TRIP W/AUX SWITCH (5 TERMINALS) SHUNT TRIP (3 TERMINALS) 3. [9.44] TYP TYPICAL TERMINAL BARRIER LINE SEE NOTE LINE TERMINAL.50 [2.954] I BACK CNECTED TERMINALS OFF O LOAD 5.25 [30.8] TYP [90.7] TYP C NO NC AUX. SWITCH TERM'S [5.05].75 [43.56].452 [36.07] SHUNT TRIP TERMINAL [90.7].250 [3.75].750 [9.05] TYP.750 [9.05] 2.60 [66.30] TYP SEE NOTE TYP STUD TERMINALS ARE SUPPLIED WITH 2 HEX NUTS AND FLAT WASHERS / TERMINALS 2.60 [66.30] LOAD TERMINAL.87 [4.75] 2.60 [66.30] TYP.203 [30.55].203 [30.55].650 [6.5].25 [3.8].390 [9.9].25 [3.8] FRT CNECTED TERMINALS.485 [2.32].485 [2.32] BOX TYPE WIRE CNECTORS.87 [4.75] BUS TYPE SCREW TERMINALS TYPICALTERMINAL BARRIER ( BACK CNECTED BREAKERS LY) LINE AUXILIARY SWITCH TERMINALS.05 DIA [Ø.30].287 [7.29].0 [2.80].26 [3.20].0 [2.80].087 [2.20].070 DIA [Ø.80] TAB (Q.C.).0 x.020 SOLDER TYPE (.0 x.020) POLE POLE 2 POLE3 LOAD MULTIPOLE IDENTIFICATI SCHEME All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.5] unless otherwise specified amps: ±.062 ± Studs long 5 amps: ±.062 ±.574 /420 Studs long 88 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
5 ESeries Form and Fit Drawings (Front Connected Type) MOUNTING INSERTS: # 632 [M3] THREAD x.220 [5.59] MIN. DEEP (2PLC'S) / POLE.026 [26.06].200 [5.08].250 [6.35] REF.53 [3.03].220 [5.59].65 [6.54] LG MOUNTING FOOT 2.60 [66.30].25 [3.8].485 [2.32] SHORT MOUNTING FOOT SEE NOTE.25 [3.8].200 [5.08] 2.56 [54.76] I 4.78 [2.44] REF +.05 [.38] [69.85].005 [.3] [57.5] [20.65] [46.8] 4.78 [2.44].25 [3.8] [60.35].25 [28.58] OFF O.375 [34.92].220 [5.59] REF..500 [2.70] TYPICAL OPTIAL "OFF, IO" LEGEND..469 [37.3].026 [26.06] MTG. SLOT CLEARANCE FOR 832 [M4] SCREW (4 PLCS.).220 [5.59] [59.40] MIN [32.85] MIN. PANEL CUTOUT DETAIL 4.85 [06.3] [53.5] MAX..026 [26.06] 3.38 [79.70] MAX..026 [26.06] TYP 6 POLES 5 POLES 4 POLES 3 POLES [59.40] MIN [32.85] MIN [06.3] MIN [79.70] MIN. 2 POLES [53.5] MIN. POLES.043 [26.50] MIN. MULTIPOLE UNITS ARE ASSEMBLED AT FACTORY WITH COMM HANDLE TIE [69.85] [58.05].232 [5.90].59 [3.20].56 [3.96] DIA 2 PLC'S. TYP. PER POLE.026 [26.06] TYP All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.5] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. For other configurations, consult factory. 4 Circuit breakers must be mounted on a vertical surface. Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
6 ESeries Form and Fit Drawings (Back Connected Type) CLEARANCE AREA SEE NOTE 2 MOUNTING INSERTS: 632 [M3] THREAD x.220 [5.59] MIN. DEEP (2PLC'S) / POLE TYPICAL ANTIFLASHOVER BARRIER 3.00 [76.2].026 [26.06] [69.85].062 [.57] I 2.56 [54.76] +.05 [±.38].005 [±.3] [57.5] [30.8].375 [34.92] [20.65] [90.7] TYP.25 [28.58] OFF O.750 [9.05] TYP.469 [37.3] TYPICAL OPTIAL "OFF, IO" LEGEND..65 [6.54].220 [5.59] SEE NOTE.026 [26.06] 2.60 [66.30] TYP. 3. [9.44] PANEL CUTOUT DETAIL [59.40] MAX [32.85] MAX. 6 POLES [59.40] MIN [06.3] MAX. 5 POLES [32.85] MIN..026 [26.06] 3.38 [79.70] MAX [53.5] MAX..026 [26.06] TYP 4 POLES 3 POLES 2 POLES POLES [53.5] MIN..043 [26.50] MIN [06.3] MIN [79.70] MIN. MULTIPOLE UNITS ARE ASSEMBLED AT FACTORY WITH COMM HANDLE TIE [69.85] [58.05].232 [5.90].59 [3.20].56 DIA [Ø3.96] 2 PLC'S. TYP. PER POLE.026 [3.20] /4 20 stud terminal in Series Trip circuit configuration shown. For other configurations, consult factory.. 2 A 3" min spacing must be provided between the circuit breaker arc venting area of back connected ESeries circuit breakers and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.5] unless otherwise specified. 5 Circuit breakers must be mounted on a vertical surface. 90 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
7 ESeries Accessories Power Selector ACCESSORY CODE 8 Circuit Breaker Accessory TOTAL SELECTOR SYSTEM POLES 6 Six poles 9 Nine poles NUMBER OF SECTIS & NUMBER OF POLES PER SECTI Sections Poles per section C Two Three G Three Three The number of sliding lockout handles provided is one less than the number of sections specified, allowing only one section to be live at one time. STYLE Carlingswitch logo 2 Textured surface 3 Glossy Surface 8 E 6 B C 3 PRODUCT SERIES E ESeries ACCESSORY TYPE B Power Selector Sliding Lockout Handle COLOR 2 Black 3 Red MOUNTING PANEL SECTI () SECTI (2) STYLE CODE SLIDING LOCKOUT HANDLE POWER OFF POWER STYLE CODE 2 SECTI () SECTI (2) OFF FF OFF 2 POWER OFF POWER OFF STYLE CODE 3 SECTI () SECTI (2) GLOSSY SURFACE FOR CUSTOMER APPLIED LABEL 3 HANDLE STYLES POWER POWER OFF Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
8 ESeries Branch Circuit Breaker Ordering Scheme PROD CODE E POLES One 2 Two 3 Three 4 Four 5 Five 6 Six AUXILIARY SWITCH 3 0 w/o Aux Switch Q.C. Term. 3 Solder Lug Q.C. Term. w/ Gold Contacts E A 2 B 0 24 ACTUATOR A Handle, one per pole CIRCUIT B Series Trip FREQUENCY AND DELAY 2 DC Short 4 DC Medium 6 DC Long 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long ESeries circuit breakers on this page are LISTED under UL Standard #489 (General and Special Purpose) and are Certified under CSA Standard #C22.2 No Standard multipole units have all poles identical except when specifying auxiliary switch (see Note 3 and Fig. A). 3. On multipole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Fig. A. Back mounted units require special mounting provisions when auxiliary switch is specified. 4. A terminal barrier is supplied between poles on multipole units with 032 stud (Terminal Code ) and /420 stud (Terminal Code 2) per UL requirement. 5a. Box Wire Connector will accept #4 through 0 AWG. copper wire or #2 through 0 AWG. aluminum wire. 5b. Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 6. Standard handle colors are white and black with OFF & dual; IO/OFF legends. 7. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. 8. Line Terminals must be same polarity. 92 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
9 ESeries Branch Circuit Breaker COIL RATING CURRENT COIL AMPERES ACTUATOR COLOR COLOR LEGEND B 6 White OnOff (Black) 6 White Dual (Black) D 6 Black OnOff (White) 2 6 Black Dual (White) G Red OnOff (White) 3 Red Dual (White) N Yellow OnOff (Black) 6 Yellow Dual (Black) MAXIMUM APPLICATI RATING VOLTAGE CURRENT B 25 VDC Amps C 20/240 VAC Amps D 240 VAC Amps Figure A POLE POLE 2 POLE 3 LOAD MULTIPOLE IDENTIFICATI SCHEME A C C AGENCY APPROVAL A W/O Approval C UL 489 LISTED and CSA Certified (Branch Circuit Breaker) TERMINAL MAX. RATING BACK CNECTED (Front Mounted Only) studs (all terminals) 50A 2 4 /420 studs (all terminals) A FRT CNECTED (Back Mounted Only) 3 5a Box Wire Connector (line & load) A C 5b Box Wire Connector w/ pressure plate (line & load) A screw (line & load) 50A Bustype screw (line), 032 screw (load) 50A 6 5a,8 032 Bustype screw (line), Box Wire Connector (load) A F 5b,8 032 Bustype screw (line), Box Wire Connector w/ pressure plate (load) A 7 /420 screw (line & load) A 8 8 /420 Bustype screw (line), /420 screw (load) A 9 5a,8 /420 Bustype screw (line), Box Wire Connector (load) A J 5b,8 /420 Bustype screw (line), Box Wire Connector w/ pressure plate (load) A MOUNTING FRT (Back Connected Only) Mounting inserts A 632 B ISO M3 BACK (Front Connected Only) 7 Back mounting Front mounting foot type insert (for opt. use) C Short 632 D Short ISO M3 E Long 632 F Long ISO M3 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
10 ESeries Supp. Protectors/Manual Motor Controllers Ordering Scheme PROD CODE E POLES 2 One 2 Two 3 Three 4 Four 5 Five 6 Six AUXILIARY SWITCH 4 0 w/o Aux Switch Q.C. Term. 3 Solder Lug Q.C. Term. w/ Gold Contacts E A 2 B 0 24 ACTUATOR A Handle, one per pole CIRCUIT 3b A 3a Switch Only (No Coil) B Series Trip (Current) D Shunt Trip (Current) FREQUENCY AND DELAY 03 DC, 50/60Hz When delay is not applicable, i.e. Switch Only circuit option. 0 DC Instantaneous 2 DC Short 4 DC Medium 6 DC Long 20 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long ESeries circuit breakers on this page are UL Recognized under the Component Recognition Program as Supplementary Protectors, (UL Standard #077) and Manual Motor Controllers. (UL Standard #508) and are also Certified to CSA Standard C22.2 No. 235 as Supplementary Protectors. 2. Standard multipole units have all poles identical except when specifying auxiliary switch (see Note 4 and Figure A). For mixed ratings, consult factory. 3a. Switch Only construction: 30 amps or less select Current Rating Code 630; 370 amps, select Current Rating code 670; 7 amps, select Current Rating Code 80. 3b. Switch Only and Series Trip construction available with either front or back connected terminals. Shunt construction available with back connected terminals, (Terminal Codes & 2) only. 4. Auxiliary Switch available on Switch Only and Series Trip units. On multipole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. 5. A terminal barrier is supplied between poles on multipole units with 032 stud (Terminal Code ) and /420 stud (Terminal Code 2) per UL requirement. 6a. Box Wire Connector will accept #4 through 0 AWG. copper wire or #2 through 0 AWG. aluminum wire. 6b. Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 7. Standard handle colors are white and black with IO, OFF and DUAL OFF/IO legends. 8. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting V and V ratings require 3 or 4 pole break 3Ø and 2 pole break Ø. 0. Line Terminals must be same polarity, rated 300V max. 94 Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
11 ESeries Supp. Protectors/Manual Motor Controllers COIL RATING CURRENT COIL AMPERES ACTUATOR COLOR COLOR LEGEND A 7 White IO (Black) B 7 White OnOff (Black) 7 White Dual (Black) C 7 Black IO (White) D 7 Black OnOff (White) 2 7 Black Dual (White) F Red IO (White) G Red OnOff (White) 3 Red Dual (White) M Yellow IO (Black) N Yellow OnOff (Black) 6 Yellow Dual (Black) MAXIMUM APPLICATI RATING VOLTAGE CURRENT B 25 VDC Amps C 20/240 VAC Amps D 240 VAC Amps E 9 277/480 VAC Amps F 277 VAC Amps G 9 VAC Amps H VAC Amps U 25 VDC/277 VAC Amps V 9 25 VDC/ VAC Amps Figure A POLE POLE 2 POLE 3 LOAD MULTIPOLE IDENTIFICATI SCHEME A C B TERMINAL MAX. RATING BACK CNECTED (Front Mounted Only) studs (all terminals) 50A 2 5 /420 studs (all terminals) A FRT CNECTED (Back Mounted Only) 3 6a Box Wire Connector (line & load) A C 6b Box Wire Connector w/ pressure plate (line & load) A screw (line & load) 50A Bustype screw (line), 032 screw (load) 50A 6 6a,0 032 Bustype screw (line), Box Wire Connector (load) A F 6b,0 032 Bustype screw (line), Box Wire Connector w/ pressure plate (load) A 7 /420 screw (line & load) A 8 0 /420 Bustype screw (line), /420 screw (load) A 9 6a,0 /420 Bustype screw (line), Box Wire Connector (load) A J 6b,0 /420 Bustype screw (line), Box Wire Connector w/ pressure plate (load) A MOUNTING FRT (Back Connected Only) Mounting inserts A 632 B ISO M3 BACK (Front Connected Only) 8 Back mounting Front mounting foot type insert (for opt. use) C Short 632 D Short ISO M3 E Long 632 F Long ISO 32 AGENCY APPROVAL A W/O Approval B UL 077 RECOGNIZED & CSA CERTIFIED (Supplementary Protector); UL 508 RECOGNIZED (Manual Motor Controller) Carlingswitch,Inc. (860) Carlingswitch, LTD. Int Carlingswitch AsiaPacific, LTD. Int
E-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and
More informationPERCENT OF RATED CURRENT
A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationD-Series. Circuit Breaker
D-Series Circuit Breaker Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It
More informationC-Series. Circuit Breaker
C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available
More informationC-Series. Circuit Breaker
C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationAPL/UPL, 205/295 Series Magnetic Circuit Protectors
APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationD-Series CIRCUIT BREAKER
D-Series CIRCUIT BREAKER Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It
More informationPERCENT OF RATED CURRENT
A-D Series Time Delay Values PERENT OF RATED URRENT NOTES: UL489 -Series Breakers available with Delay urves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay urves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationTime Delay Values (A, B, C & D-Series) AC 10000
Time Delay Values (A, B, & D-Series) A 0 Instantaneous INSTANTANEOUS URVE. 20 0 D D.. INSTANTANEOUS URVE. 0 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Ultrashort.00 0 200 300 400 500 600 700 800
More informationAPG/UPG/IPG Series Existing Designs Only APG/UPG/IPG
APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION IMPORTANT NOTICE: The APG/UPG is a legacy product and no new design-in orders
More information209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS
209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS Introduction The 209, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or
More informationSingle Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles
Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles and Actuators 89 IPG Breakers 90 Configurations 9 Operating
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationIhr autorisierter Distributor: Neumüller Elektronik GmbH
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More informationM-Series. Circuit Breaker
M-Series Circuit Breaker The M-Series is a low cost, miniature hydraulic/magnetic circuit breakers ideally designed for demanding applications requiring space saving features, aesthetics and snap-in front
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationPD-Series General Specifications
PD-Series General Specifications SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection.
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationPC-Series Ground Fault Circuit Protection
PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
Series Magnetic Circuit Protectors Introduction 53 Single Pole 54 Specifications 55 Operating Characteristics 56 Delay Curves 57 Approvals & Decision Tables 6 IELR Series Hydraulic Magnetic Circuit Protectors
More informationW69-X2Q12-20 Product Details
TE Connectivity My Cart My Part Lists Sign In/Register English (Change) Have a Question? Chat with a Product Information Specialist What can we help you find? Products Industries Resources bout TE My ccount
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationContact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect
V Miniature Snap Action Switch Industry standard design with 10/15 Amp ratings Long mechanical life of 50,000,000 operations minimum Available in either thermoplastic or thermosetting resin Can be used
More informationW91-X Product Details
TE Connectivity My Cart My Part Lists Sign In/Register English (Change) Have a Question? Chat with a Product Information Specialist What can we help you find? Products Industries Resources bout TE My ccount
More informationD2SW-3L1HS D2SW-01L1HS
Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationIAR/IUR/IER/CUR/CER Series 1RU Magnetic Circuit Protectors
IAR/IUR/IER/CUR/CER Series RU Magnetic Circuit Protectors IAR/IUR/IER/CUR/CER [RU] Introduction 49 Poles & Terminals 50 Configurations 53 Delay Curves & Specs 54 Operating Characteristics 55 Hardware 56
More informationCROWN LINE Power Bus Bar Distribution System
COWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System The pluggable bus bar system Currents up to 300 Amps Up to 2 meters in length Pluggable breakers VDE finger proof
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 100 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationType CBW58 Thermal Circuit Breaker Push to Reset Standard Profile
Specifications: Amperage Range: 3A - 50A Voltage: 125 / 250 VAC, 50 VDC Frequency: 50-60 Hz Dielectric Strength: 1,500 VAC / 1 Minute Interrupting Rating: 3-50A 1000A @ 125/250VAC 3-30A 400A @ 125/250
More information16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever
Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationType CBW57 Thermal Circuit Breaker Push to Reset Low Profile
Specifications: Push to Reset - Low Profile Amperage Range: 3A - 30A Voltage: 125 / 250 VAC, 32 VDC Frequency: 50-60 Hz Dielectric Strength: 1500 VAC / 1 Minute Interrupt Rating: 3-30A 1000A @ 125/250
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationClassification Enclosure rating Input voltage Type of
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationIntroduction to High Current Card Edge Connectors
Introduction to High Current Card Edge Connectors Product Facts Contacts on.100 [2.54] Centerlines Selective gold plating of contacts for high performance at low cost Flow solder applications Glass-filled
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationSolid State Remote Power Controller E
Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient
More informationPERFORMANCE SPECIFICATION
INCH-POUND MIL-PRF-6106/13F 17 November 2011 SUPERSEDING MIL-PRF-6106/13E 10 November 2000 PERFORMANCE SPECIFICATION RELAY, ELECTROMAGNETIC, 25 AMPERE, 3PST, NO, WITH 2 AMPERE 1PDT AUXILIARY CONTACTS,
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationContact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect
VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationmust Operate Voltage (V)
force-guided relays g7sa G7SA compact, Slim relays conforming to en Standards Relays with forcibly guided contacts (EN50205 Class A, certifi ed by VDE) Supports the CE marking of machinery (Machinery Directive)
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More information78 Series Electromechanical Relay Selection Guide
78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5
More informationModel Number Structure
Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationOrdering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend
Door Interlock Switch D2D Power Switch with Minimum Contact Gap up to 3 mm. Minimum contact gap of 3 mm (standard models), needed in general power switches, is provided. Mechanism with double return spring
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationD2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -
Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water
More informationSolid-state Timer H3YN
Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationActuator Terminal Model
Sealed Snap ction Switch D2VW Watertight Miniature Snap ction Switch High-quality watertight, high-precision miniature Snap ction switch. Switch Body meets IP67 requirements Use of epoxy resin assures
More informationBasic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever
Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements IEC 529 (lead wire type) Monoblock construction assures high
More informationPosi-Lok Plugs and Panels
THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More informationA16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.
Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable
More informationModel 720 Electromechanical Hour Meter
Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models
More informationContact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)
D3D Miniature Door Switch Appliance industry standard plunger and lever actuator styles High contact reliability ensured using gold alloy crossbar contacts Drip/spill sealing in free position (plunger
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationTerminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB
Subminiature Basic Switch SS-P SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept Insert molded base and improved case-to-base seal provides enhanced resistance to
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationV REG.-Nr. 3919, Z E214024
General Purpose Relays SCHRACK Miniature Power PCB Relay MSR 1 pole 8 / 10 A, 1CO or 1NO contact High inrush currents with AgSnO contacts (TV4 = 65 A) 4 kv/8 mm coil-contact Reinforced insulation (protection
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationmasterelectronics.com onlinecomponents.com
Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements (IEC 529) Monoblock construction assures high sealing capability
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationCircuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V
CP3E, 32E, 33E, 34E CP3V, 32V, 33V, 34V CP-E and CP-V circuit protectors 250V AC 0.05A to 30A 65V DC 0.05A to 30A Description CP-E, CP-V circuit protectors have been specially developed for computers,
More information