1 2-Port DS3 ATM Module Description and Technical Specifications Purpose of This Document This document identifies and describes the 2-Port DS3 ATM module and related safety information. It also includes procedures for installation and removal of the module from the PSAX chassis and verification of the initial module startup, as well as references to configuration documentation and troubleshooting assistance. Regulatory standards compliance is also described for the module. Identifying the Module The 2-Port DS3 ATM module is illustrated in Figure 1. FAIL ACTIVE DS3 ATM TX L0S RX TX L0S RX Figure 1. 2-Port DS3 ATM Module The 2-Port DS3 ATM module has been tested and verified by Lucent Technologies to operate with the following PSAX software releases: COMCODE Software Release Model Faceplate Label and subsequent 20N02 DS3 ATM 2-Port DS3 ATM Module Description and Technical Specifications Page 1 of 8 Part Number: 508M0A0001Z3 Document Number:
2 Safety Information When installing and operating the 2-Port DS3 ATM module, follow the safety guidelines provided in the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, to help prevent serious personal injury and damage to the module. Please read all warnings and instructions supplied before beginning installation or configuration of this module. In addition to the general safety information provided, you should also refer to the text in the PacketStar PSAX installation guides for other important safety information and procedures. Hardware Specifications Supported Description of the Module Functional Description The 2-Port DS3 ATM module has the following hardware features: Number of ports: two Connector type: four BNC connectors for the two ports (each port has one receive connector and one transmit connector) Line rate: Mbps (typical) Line encoding mode: B3ZS Line type: C-bit parity, clear channel Loopback capabilities: local loop, line loop, payload loop Transmit clock: Local timing, loop timing Line buildout: short [ m (0 133 ft)]; long [ m ( ft)] Cell mapping: PLCP, direct mapping The 2-Port DS3 ATM module provides a network interface at Digital Signal Level 3 (DS3), with a line rate of Mbps. Typically, this module is used to connect the PSAX system to an ATM edge switch or digital subscriber line aggregation multiplexer (DSLAM) device. Physical and Environmental Specifications Table 1 provides the general physical hardware and environmental specifications for the PSAX I/O module. Table 1. Physical Hardware Specifications for the PSAX I/O Module Dimensions Specification Weight Operating temperature range for all the PSAX 1250, PSAX 2300, and PSAX 4500 systems Description 17.3 cm H x 2.41 cm W x 24.1 cm D (6.8 in. H x 0.95 in. W x 9.5 in. D) 0.45 kg (1.0 lb.), approximate 0 to 50 C (32 to 122 F) Page 2 of 8 2-Port DS3 ATM Module Description and Technical Specifications
3 Table 1. Physical Hardware Specifications for the PSAX I/O Module (Continued) Specification Operating temperature range for the PSAX 1000 systems Description For AC-powered PSAX 1000 systems: 0 to 50 C (32 to 122 F) For DC-powered PSAX 1000 systems: -20 to 60 C (-4 to 140 F) with a cold start minimum of 0 C (32 F) Operating humidity range for all chassis 5% to 85% relative humidity Operating altitude range for all chassis 60 meters (197 feet) below sea level to 4,000 meters (13,123 feet) above sea level Storage temperature range for all chassis Storage humidity range for all chassis -40 to 70 C (-40 to 158 F) 0% to 90% noncondensing Performance and Power Specifications Table 2 provides the chassis speed, power consumption, and memory allocation specifications for this module. Table 2. Performance and Power Specifications for the 2-Port DS3 ATM Module 20N02 ATM Module 2-Port DS3 Total Amount of SDRAM Module Program and Data Space Maximum Input Buffer * Output Buffer 8MB 3MB 1MB 4MB (65,536) Chassis Speed Low Speed Maximum Power Consumption 15 W * The I/O buffers carry 16,384 cells per megabyte. Indicates the size of the output buffer followed by the maximum number of 64-byte cells in the output buffer. This column relates only to the speed at which the module communicates within the chassis. A high-speed module will communicate at high speed (1.2 Gbps) in a chassis that has a high-speed bus (PSAX 4500 chassis). High-speed modules will communicate at 600 Mbps in any other chassis. Low-speed modules will always communicate at 600 Mbps in any chassis. Module Placement The 2-Port DS3 ATM module is installed in any PSAX chassis slot intended to contain an I/O or server module. If you are installing the module in a newly installed PSAX chassis, be sure to follow your facility site plan for placing this module in the correct location in the chassis. Installing the Module Perform the following procedure to install PSAX I/O modules into a PSAX chassis. Read the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, before proceeding. 2-Port DS3 ATM Module Description and Technical Specifications Page 3 of 8
4 ! WARNING: Be sure to use the ejector handles during installation and removal of a PSAX module.! WARNING: Make sure the locking tab at the bottom of the module (looking at module in a vertical position) is UP before you insert it into the chassis.! WARNING: When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis. Install or remove modules one at a time. Doing this aids in preventing the PSAX system from indicating any erroneous failure messages, and allows the PSAX system time to reinitialize and display the accurate configuration of the module that is inserted. Begin 1 Remove the module from its box and ESD protective bag only when you are ready to install it. Be sure to save the box and the ESD bag to ship the module in the future if needed. 2 Open the ejector handle at the top of the module faceplate, and slide the module into an available slot. Be sure to position the module with the ejector handle near the top edge of the chassis opening on the PSAX 1250, PSAX 2300, and PSAX 4500 chassis. Position the module horizontally in the PSAX 1000 chassis with the ejector handle to the left. 3 Press the ejector handle until it snaps firmly against the faceplate, and verify that the module is secure in its slot. 4 Engage the locking tab based on the PSAX chassis in use as follows: For the PSAX 1000 chassis, insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab to the right (see Figure 2). For the PSAX 1250 chassis, the locking tab is not used. Skip this step and continue with the procedure. For the PSAX 2300 or the PSAX 4500 chassis, insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab down and into the locking tab slot (see Figure 3). Page 4 of 8 2-Port DS3 ATM Module Description and Technical Specifications
5 Locking Tab (Unlocked) Screwdriver Slot Locking Tab (Locked) Figure 2. Engaging the Module Locking Tab on the PSAX 1000 Chassis 4 5 For new installations, run the cabling through a cable management system that provides the necessary connector/cable strain relief to prevent damage to the I/O module connectors.! WARNING: To prevent any damage to the I/O module connectors, do not allow network cables to hang unaided from the connectors. Use standard cable installation procedures to run and secure the network cables through an appropriate cable management system before connecting the cables to the I/O modules. End Figure 3. Engaging the Module Locking Tab on the PSAX 4500 or PSAX 2300 Chassis) 2-Port DS3 ATM Module Description and Technical Specifications Page 5 of 8
6 Verifying the Initial Startup After you insert the 2-Port DS3 ATM module into the chassis, observe the LED status indicators as described in Table 3. If the status indicators do not appear to function properly, refer to Troubleshooting the Installation on page 8. Table 3. LED Indicators for the 2-Port DS3 ATM Module LED FAIL (red) ACTIVE (green) LOS (Loss of Signal) (yellow) Initial Power-On No Configured Ports One or More Configured Ports Lights briefly * Not lit Lights only when the module is not functioning Lights briefly * Not lit Lights only when the module is functioning properly Lights briefly Module Status No Cable on Port Lights Cable on Port Does not light if signal is being received. Lights if signal is missing. * After power is initially applied to the system and the system boot is complete, the FAIL and ACTIVE LEDs indicate whether the module has no configured ports (red), or one or more configured ports (green). After power is initially applied to the system and the system boot is complete, the LOS LED indicates whether the port has a cable connected to it. Removing the Module Perform the following procedure to remove the module. Read the PacketStar PSAX Multiservice Media Gateway Safety Guidelines, which accompanies this product, before proceeding.! WARNING: Be sure to use the ejector handles during installation and removal of a PSAX module. Removing an I/O Module or a CPU2 Module Begin 1 Disconnect the cables from the module port (or ports). 2 Disengage the locking tab based on the PSAX chassis as follows: For the PSAX 1000 chassis, insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab to the left (see Figure 4). For the PSAX 1250 chassis, the locking tab is not used. Skip this step and continue the procedure. Page 6 of 8 2-Port DS3 ATM Module Description and Technical Specifications
7 For the PSAX 2300 or the PSAX 4500 chassis, insert a flathead screwdriver into the screwdriver slot of the locking tab, and slide the locking tab up and out of the locking tab slot (see Figure 5). 3 Pull backward on the ejector handle until the module is released from the midplane/backplane. Locking Tab (Unlocked) Screwdriver Slot Locking Tab (Locked) Figure 4. Locking Tab on the Module, on the PSAX 1000 Chassis 4 Figure 5. Locking Tab on the Module (Shown in a PSAX 4500 Chassis) 4 Remove the module from the chassis. 5 Put the module in its ESD bag, close the bag, and place the module in its original shipping box. 6 If another module is not being immediately inserted into the empty slot, insert a blank faceplate module into the slot to prevent electromagnetic interference (EMI) and maintain proper air flow inside the chassis. 2-Port DS3 ATM Module Description and Technical Specifications Page 7 of 8
8 ! CAUTION: Ultimate disposal of this product should be handled according to all laws and regulations in your specific geographic region. End Configuring the Module For information on configuring the ports and channels, interfaces, and connections for this module, see the Product Information Library CD-ROM that accompanied your PSAX Multiservice Media Gateway system software shipment. You can also separately order a printed copy of the PacketStar PSAX 2-Port DS3 ATM Module User Guide from the Lucent Technologies Customer Information Center Web site at: Troubleshooting the Installation If you experience a problem with the 2-Port DS3 ATM module, refer to the Lucent Technologies Product Warranty Registration Information, which accompanied your shipment, for instructions on obtaining support in your area. Regulatory Standards Compliance Safety and Electromagnetic Compatibility (EMC) The following PacketStar PSAX systems are compliant with applicable safety and EMC standards when configured with the 2-Port DS3 ATM module (model 20N22): PSAX 1000 system PSAX 1250 system PSAX 2300 system PSAX 4500 system Please refer to the PacketStar PSAX 1000, PSAX 1250, PSAX 2300, or PSAX 4500 Multiservice Media Gateway installation guide for details on safety and EMC standards compliance. The information in this document is for informational use only, is subject to change without notice, and should not be construed as a commitment by Lucent Technologies, Inc. This document is without warranty of any kind, either expressed or implied. Lucent Technologies, Inc. assumes no responsibility for any errors, inaccuracies, or omissions. Neither is any liability assumed for damages resulting from the use of the information or instructions contained herein. Lucent Technologies, Inc. is not responsible for any damage or loss to your data or equipment resulting either directly or indirectly from use of this document. Lucent Technologies has made a commitment to reduce the environmental impact of its products by reusing and recycling material. In keeping with this commitment, this document is printed on paper containing 100% recycled paper. We encourage you to support the principle of reduction, reuse, and recycling of materials by recycling this product when it is no longer needed. Copyright 2004 Lucent Technologies All rights reserved. Printed in the USA. Part Number: 508M0A0001Z3
1-Port Channelized OC-3/STM-1 CES Multimode and Single-Mode Modules Description and Specifications. The modules are shown in Figure 1.
1-Port Channelized OC-3/STM-1 CES Multimode and Single-Mode Modules Description and Specifications Purpose of This Document This document identifies and describes the 1-Port Channelized OC-3/STM-1 CES
More informationInstalling the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS MA
Installing the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS 15310-MA Product Names: 15310-28WBE-3BBE, 15310-84WBE-3BBE This document provides a card description, specifications, and an
More informationPerle MCR200 Installation Guide
Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT
More informationDell SC7020 Storage Controller Getting Started Guide
Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
More informationInstallation Notes for the Cisco TwinGig and OneX Converter Modules
Installation Notes for the Cisco TwinGig and OneX Converter Modules PID: CVR-X2-SFP and CVR-X2-SFP10G This note provides the installation instructions for the Cisco TwinGig and OneX Converter Modules.
More informationInstalling the IPS 4345 and IPS 4360
CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product
More informationSCv360 Expansion Enclosure
SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:
More informationDell SC460 Expansion Enclosure Getting Started Guide
Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationSATADOM. for Dell PowerEdge R630, R730, and R730xd systems
SATADOM for Dell PowerEdge R630, R730, and R730xd systems Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More informationDell SCv300 and SCv320 Expansion Enclosure Owner's Manual
Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationDell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001
Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing
More informationManaging Individual Components
CHAPTER 3 This chapter describes how to install the Field Replaceable Units (FRUs) in the Cisco SFS 7008P system. About the Field Replaceable Units The following Field Replaceable Units (FRUs) are a part
More informationWhat is a Hotwire Shelf Concentration Module?
Hotwire Shelf Concentration Module (SCM) Card Installation Instructions Document Number 8021-A2-GZ40-40 February 2001 What is a Hotwire Shelf Concentration Module? A Hotwire Shelf Concentration Module
More informationRemoving and Installing the ISA and the ISM
CHAPTER This chapter describes how to remove the ISA or ISM from supported platforms and also how to install a new or replacement ISA or ISM. This chapter contains the following sections: Handling the
More information14 USB devices or 3 USB hubs with 11 USB devices. Input: 100/240 V AC, Hz, 600 ma maximum Output: 5 V DC, 3 A
Please visit Icron s website for answers to FAQs: http://www.icron.com/faq Specifications - USB r 2201 USB hub support 100m (330ft) over Cat 5e (or better) cable Full speed devices (12 Mb/s) (USB 2.0 &
More informationCisco UBR-MC20X20V Cable Interface Line Card Quick Start Guide
Cisco UBR-MC20X20V Cable Interface Line Card Quick Start Guide First Published: November 16, 2009 Last Updated: May 10, 2010, Overview The Cisco UBR-MC20X20V cable interface line card transmits and receives
More informationInstalling IDS Introducing IDS-4215 CHAPTER
CHAPTER 3 This chapter describes IDS-4215 and how to install it. It also describes the accessories and how to install them. This chapter contains the following sections: Introducing IDS-4215, page 3-1
More informationStacking Module. Installation Guide AT-MCF2000S. PN Rev A
Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission
More informationDell Vostro 1014 and 1015 Setup and Features Information Tech Sheet
About Warnings WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Dell Vostro 1014 and 1015 Setup and Features Information Tech Sheet Front View 1 2 3 4 17 16 5 15
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More informationWhat is a Hotwire 8310 MVL Card?
Hotwire 8310 MVL Card Installation Instructions Document Number 8310-A2-GZ40-20 January 2000 What is a Hotwire 8310 MVL Card? A Hotwire 8310 MVL (Multiple Virtual Lines) card is a circuit card assembly
More informationInstallation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules
Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules Published: April, 2010 Revised: April, 2013 For information about using the power supply modules with a switch, see the
More informationInstalling a Network Module
3 CHAPTER This chapter describes how to install and connect a network module. Overview, page 3-1 in the Switch, page 3-4 SFP and SFP+ Modules, page 3-7 Finding the Network Module Serial Number, page 3-9
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity Hybrid Replacing a faulted 3.5-inch disk drive 302-002-595 REV 01 May, 2016 This document describes how to replace a faulted 3.5-inch disk drive in the Unity
More informationMaintaining E-Series Routers
Maintaining E-Series Routers 9 This chapter lists the tools, items, and steps needed for installing and uninstalling E-series components. Other maintenance procedures must be performed by an authorized
More informationDell Latitude E5410/E5510
Dell Latitude E5410/E5510 Setup and Features Information About Warnings WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Latitude E5410 Front View 19 18 20 21 17
More informationInstalling a Network Module
Network Modules Overview, page 1 in the Switch, page 2 Removing a Network Module, page 10 SFP and SFP+ Modules, page 11 Finding the Network Module Serial Number, page 13 Network Modules Overview The Cisco
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
More informationDell Vostro 1310/1510/1710/2510 Setup and Features Information
9 A WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Dell Vostro 1310/1510/1710/2510 Setup and Features Information Vostro 1310 1 2 3 4 5 6 13 12 10 9 8 7 11 January
More informationGB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.
IBM System Storage DS4800 Controller Cache Upgrade Kit Instructions Attention: IBM has renamed some FAStT family products. FAStT EXP100 has been renamed DS4000 EXP100, FAStT EXP700 has been renamed DS4000
More informationMaintaining the ERX System
7 This chapter describes the procedures that you must perform to maintain the ERX system and its components. Other maintenance procedures must be performed by an authorized Juniper Networks technician.
More informationInstalling Power Modules
This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,
More informationUSB 3.1 CAT6A/7 EXTENDER
USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION
More informationInstalling a Network Module
Network Module Overview, page in the Switch, page 7 Removing a Network Module, page 3 SFP and SFP+ Modules, page 4 Finding the Network Module Serial Number, page 6 Network Module Overview Network Module
More informationKvaser Leaf Light v2 User s Guide
Kvaser Leaf Light v2 User s Guide Copyright 2011-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Thursday 20 th March, 2014 We believe that the information contained herein was accurate in
More informationHP Rack Storage/12 Installation Guide
HP Rack Storage/12 Installation Guide HP Part Number D5989-90000 Printed in October 1998 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no
More informationSwitchBlade Switch Controller Quick Install Guide
SwitchBlade Switch Controller Quick Install Guide SwitchBlade Switch Controller Quick Install Guide Document Number. Copyright 2002-2005 Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite
More informationInstalling the Cisco ADE 2130 and 2140 Series Appliance Hardware Options
CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE
More informationPerle SMI Media Converter Installation Guide
Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
More informationPerle 10/100/1000 Ethernet Extender Modules. 10/100 10/100/1000 (Gigabit)
Perle 10/100/1000 Ethernet Extender Modules 10/100 10/100/1000 (Gigabit) ex-1c/cm110-rj ex-1c/cm110-bnc ex-1c/cm110-tb ex-1c/cm1110-rj ex-1c/cm1110-bnc ex-1c/cm1110 -TB Part# 5500331-11(Rev A) Version:
More information14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10
14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 2 Copyright 2007. International and its licensors. All rights reserved. 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 3 Contents Contents
More informationCustomer Replacement Procedure
Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace
More informationReplacing an Advanced Power and Cooling (APC) Unit
Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DominoPLUS Installation Guide DA-360 BN 9314/96.29 1998 Wandel & Goltermann, Inc. Microsoft is a registered trademark
More informationDell Networking S4810 Open Networking (ON) Getting Started Guide
Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationDell Latitude E6220. Setup And Features Information. About Warnings. Front And Back View
Dell Latitude E6220 Setup And Features Information About Warnings WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Front And Back View Figure 1. Front View 1. microphone
More information3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE
3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology
More informationKvaser USBcan Light User s Guide
Kvaser USBcan Light User s Guide Copyright 2018 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Wednesday 16 th May, 2018 We believe that the information contained herein was accurate in all respects
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationKvaser Leaf Light v2 User s Guide
Kvaser Leaf Light v2 User s Guide Copyright 2011-2016 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Thursday 15 th September, 2016 We believe that the information contained herein was accurate
More informationPort Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline
C-Series FlexMedia Card: 36 Ports 10/100/1000 Base-T Ethernet (PoE and non-poe), 8 Ports 1G, 2 Ports 10G Feature Highlights and Installation Instructions Feature Highlights There are two versions of the
More informationDell Networking S4100-ON Series. Set-Up Guide
Dell Networking S4100-ON Series Set-Up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either
More informationUSB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies
More informationDell SCv3000 and SCv3020 Storage System Getting Started Guide
Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationSySTIUM TM TECHNOLOGIES Model 215
SySTIUM TM TECHNOLOGIES Model 215 MotherBoard Ready SM System ASSEMBLY GUIDE SySTIUM TM TECHNOLOGIES MOTHERBOARD READ Y SM SYSTEM MODEL 215 Radio Frequency Interference Notice (USA) This equipment has
More informationReplacing a 3.5-inch disk drive
EMC VNXe Replacing a 3.5-inch disk drive 302-000-213 REV 02 July, 2015 This document describes how to replace a disk drive in a supported 12-slot disk enclosure: 12-slot disk processor enclosure (DPE)
More informationCustomer Upgrade Procedure
Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive
More informationCatalyst 6500 Series Wireless LAN Services Module Installation and Verification Note
Catalyst 00 Series Wireless LAN Services Module Installation and Verification Product number: WS-SVC-WLAN--K This document provides installation procedures for the Catalyst 00 series Wireless LAN Services
More informationUSB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1
USB 2.0 SR Extender over one CAT-5 Cable EXT-USB2.0-SR User Manual Version A1 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.
More informationFR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH
FR-IB100/PCIe FlexRay PCI Express Interface Card USER MANUAL 4.01.0103.20000 2.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform
More informationInstalling ONS SDH OC3 IR 4/STM1 SH 1310 Cards
Installing ONS 15454 SDH OC3 IR 4/STM1 SH 1310 Cards Product Name: 15454E-S1.1-4= This document contains a description of OC3 IR 4/STM1 SH 1310 card features, installation procedures, removal instructions,
More informationHP Deskjet F2100 All-in-One series. Basics Guide
HP Deskjet F2100 All-in-One series Basics Guide Hewlett-Packard Company notices The information contained in this document is subject to change without notice. All rights reserved. Reproduction, adaptation,
More informationKvaser Leaf Light v2 User s Guide
Kvaser Leaf Light v2 User s Guide Copyright 2011-2017 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Wednesday 13 th September, 2017 We believe that the information contained herein was accurate
More informationSGI InfiniteStorage 120
SGI InfiniteStorage 120 Mass Storage Hardware Topics Edition 003 007-4853-003 Proprietary Rights Notices COPYRIGHT 2006, 2007 SGI. All rights reserved; provided portions may be copyright in third parties,
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Replacing a faulted 2.5-inch disk drive 302-002-594 REV 01 May, 2016 This document describes how to replace a faulted 2.5-inch
More informationHard Drive/Solid-State Drive Replacement Instructions
Hard Drive/Solid-State Drive Replacement Instructions 925496-001 Before you begin Observe the following requirements before removing and replacing the hard drive or solid-state drive. WARNING: To reduce
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationTBX-1316 High-Voltage Attenuator Terminal Block
INSTALLATION GUIDE TBX-1316 High-Voltage Attenuator Terminal Block This guide describes how to install and use the TBX-1316 high-voltage attenuator terminal block with the following modules: SCXI-1125
More informationSwitched Uplink Modules
APPENDIX D Switched Uplink Modules When installed in a FastHub 400 model, each 10BaseT/100BaseTX and 100BaseFX switched uplink module provides a separate switched collision domain for traffic to the workgroup
More informationKvaser USBcan Light 4xHS User s Guide
Kvaser USBcan Light 4xHS User s Guide Copyright 2015-2015 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Monday 21 st September, 2015 We believe that the information contained herein was accurate
More informationPower Enclosure Components
Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class
More informationInstallation Job Aid for Avaya Virtual Services Platform 8400
Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing
More informationKvaser PCIEcan 2xHS v2 User s Guide
Kvaser PCIEcan 2xHS v2 User s Guide Copyright 2016-2017 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Friday 5 th May, 2017 We believe that the information contained herein was accurate in all
More informationDell SC5020 and SC5020F Storage Systems Getting Started Guide
Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationInstalling and Upgrading Memory and Virtual Private Network Modules
APPENDIX C Installing and Upgrading Memory and Virtual Private Network Modules This chapter tells how to install or upgrade memory and how to install a Virtual Private Network (VPN) module in your Cisco
More informationInstalling System Board Options
CHAPTER 8 Installing System Board Options This section describes how to install the following options: Expansion cards Memory modules Microprocessor This section also includes instructions for replacing
More informationInstallation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:
Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes
More informationPerle Cx-10GR-STS Media Converter Modules
Perle Cx-10GR-STS Media Converter Modules Installation Guide C-10GR-STS CM-10GR-STS P/N 5500435-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More informationDell PowerVault MD3060e Storage Enclosure Owner's Manual
Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More informationInstallation Guide HP J3102A
Guide HP J3102A HP AdvanceStack Switch Ethernet Module HP Customer Support Services How to get the latest software You can download a compressed file ( j3100a.exe) containing the latest version of the
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationInstallation Instructions
Installation Instructions (Cat. No. 71-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Because of the variety of uses for the products described in this publication, those responsible for the application and use
More informationPower Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationH3C SecPath M9000-S NSQM2MPUD0 main processing unit
H3C SecPath M9000-S NSQM2MPUD0 main processing unit 1 Identifier The module identifier NSQM2MPUD0 is at the upper right corner of the front panel. 2 The NSQM2MPUD0 MPU has a console port, a USB port, a
More informationUSB 2.0 CAT5E/6/7 EXTENDER
USER MANUAL IC402A-R2 USB 2.0 CAT5E/6/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM + + + + Mode Config Power Link Host Activity Power Link Host Activity TABLE OF CONTENTS PRODUCT OPERATION AND STORAGE... 3
More informationKvaser PCIEcan 4xHS User s Guide
Kvaser PCIEcan 4xHS User s Guide Copyright 2015-2017 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Wednesday 13 th September, 2017 We believe that the information contained herein was accurate
More informationS4112-ON Series. Setup Guide
S4112-ON Series Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage
More informationSleepMinder TM Non Contact Sleep Monitoring
SleepMinder TM Non Contact Sleep Monitoring ABOUT THE SLEEPMINDER TM The SleepMinder TM uses a specially-designed motion sensor to detect body movement associated with sleeping. It can be used in the home,
More information