Manual Control Unit GFC 32

Size: px
Start display at page:

Download "Manual Control Unit GFC 32"

Transcription

1 Manual Control Unit _EN/

2 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control 8 8. Shut down cleaning 8 9. Low pressure Short circuit alarm of the outputs Microprocessor failure alarm Troubleshooting Fuse table Factory settings/program menu Legend Simatek :20: General assembly Electric diagram for Simatek : 20 valves Declaration of Conformity 15 NOTE: Figures shown inside square brackets [ ] refer to positions on page 13. ATTENTION: Before use, read the instructions thoroughly to acquire sufficient knowledge of the product. For your convenience, keep this sheet as a quick reference. Subject to change without notice. Note: The unit is to be installed by trained personnel only! aftersales@simatek.dk 2 Doc. No.: _EN

3 1. Main features The Simatek has been designed to guarantee the control of diaphragm valves mounted on pulse jet dust collector filters containing filter bags or cartridges. The main features of the Simatek are: Manual selection of Pulse and Pause time. Can be operated by a remote pressure switch or PLC. Automatic load search for connected valves, while ignoring outlets which have not been connected. Shut down cleaning with selectable number of cycles. 2. Technical features Enclosure Grey ABS transparent cover Grade of protection IP65 Dimensions Simatek : 20/32 outputs: case 296 x 256 x 118. Weight Simatek : 20/32 outputs: approx. 3.5 kg. Connections Push in terminal plugs max. section 2.5 mm². Temperature Storage: -20 C/+80 C. Operating: -10 C/+50 C, with duty cycle 30 % Voltage available Input: 230 V (±10%) 50/60 Hz / Output: 115/230/24V AC, 24 V DC. Input: 115 V (±10%) 50/60 Hz / Output: 115/24V AC, 24 V DC. See page 6, 6.1 Special version 24V DC/24V DC Power consumption Without output 2.5 VA. Output: max 25 VA / AC or 20 W / DC. Pulse time sec Pause time sec Max duty cycle 30 % Remote control Activated via external contact (normally open) free of power. Shut down cleaning To be operated from the normally closed contact of fan remote control switch Alarm relay Short circuit or Watch Dog (electronic surveillance of the microprocessor) Relay max 2 A 250 V AC, free contact Main fuse 1 A delayed V; 2 A delayed V AC and 24 V DC power supply The device should be disposed of in accordance with current European regulations The neutral of the power supply shall be connected to earth. If this is not the case an isolation transformer is to be installed and the neutral of the output to be earthed. Otherwise the filter control will be damaged. aftersales@simatek.dk 3 Doc. No.: _DK

4 3. Installation guidelines Do not expose the control unit to direct sunlight in order to prevent overheating of the circuit board. Connect the control unit to a continually powered line to allow SHUT-DOWN CLEANING when the fan stops. Protect the control unit from rain, water infiltration and humidity. Incomplete closing of the cover may cause infiltration which can seriously damage the circuit board. Do not have cables entering via the upper part of the control unit. Do not install any electronic devices on vibrating structures. Use only cable glands with protection grade IP65 and of proper size (according to the cable used). A disconnecting switch has to be installed on the power line before the control unit. Do not attempt to repair the control unit contact Simatek! All wiring has to be carried out by a qualified electrician to prevent any risk of fire and electrical shocks. Control unit wiring has to be performed in such a way that the different types of cables, (power, relay s contact, valve output, 4-20 ma output) are kept separate and not passing close by the PCB. Before opening the unit make sure that the control unit is switched off (switch on/off [1] on 0 and wires on clamps [4] disconnected, including connection to alarm/signal relays. All electrical connections of the control unit, including solenoid valves, have to use separate paths in respect to the other loads. Voltage selector s jumpers have to be positioned only by skilled personnel and following the instructions. A wrong voltage selector s jumpers positioning may cause potential danger to the personnel safety. aftersales@simatek.dk 4 Doc. No.: _EN

5 4. Preliminary checks 1. Check that the Simatek does not have power (switch on/off [1] on 0 and terminals [4] disconnected). 2. Check that the supply voltage indicated on the yellow label [22] as IN, corresponds to the available power supply (Voltage end Frequency). 3. Check that the supply voltage to valves indicated on the yellow label [22] as OUT, corresponds to the voltage / frequency as indicated on the coils. 5. Electrical connections 1. Unscrew and remove the terminals cover [20]. 2. Check that Simatek does not have power (on/off switch [1] on 0 and terminals [4] disconnected). 3. Extract the removable terminals [2]. 4. Check that the supply voltage to valves indicated on the yellow label [22] as OUT corresponds to the voltage/frequency as indicated on the coils. 5. Connect the valves to the terminal blocks [2], between terminal C and the numbered outputs. 6. Earthing [3] of the valves is necessary when output voltage is 48 V. 7. NEVER connect the Common or valve output to earth [3]. 8. The Commons are interconnected on the printed circuit board. 9. The outputs are static type, with zero crossing command, to prevent electrical disturbances. 10. Check that the valve connections are correct and isolated in regard to earthing, by measuring the isolation between Ground [3] and Common with outputs terminal. 11. Put the extractable terminals [2] back in place. 12. Replace the terminals cover [20] and replace the screws. aftersales@simatek.dk 5 Doc. No.: _DK

6 6. Settings 6.1 Voltage selection CHECK: 1. That the Simatek does not have power (switch on/off [1] on 0 and terminals [4] disconnected). 2. That the supply voltage indicated on the yellow label [22] as IN corresponds to the available supply voltage (Voltage and frequency). 3. That the supply voltage to valves indicated on the yellow label [22] as OUT corresponds to the voltage/frequency indicated on the coils. If these 3 conditions are met, go to paragraph 6.2. Otherwise, carefully follow the procedure below! A. Supply voltage selection 1. Unscrew the 2 screws [21] (optional), and open the Simatek transparent cover. 2. Remove the 4 screws of the front panel. Lift the front panel (do not remove it as it is connected to the base of the enclosure!). 3. Check that the supply voltage, selectable by jumper [5], corresponds to the one available from the supply voltage (e.g. both are set to 230 V). 4. Should the two voltages be different, move the jumper [5] in order to select the same supply voltage. 5. Go to point 6.1.B. B. Selection of power supply to the valves 1. Check that the supply voltage to the valves selectable by jumpers [6] and [6A] corresponds to the supply voltage indicated on the coils of the valves (e.g. both are set to 24 V). 2. Should the two voltages be different, move the jumpers [6] and [6A] in order to select the same supply voltage as indicated on the coils. 3. Caution: both jumpers [6] and [6A] must correspond to the same voltage! 4. Go to point 6.1.C. C. Selection of power supply frequency to the valves (AC/DC) 1. Make sure that the output frequency to the valves, selectable by jumpers [8], corresponds to the value indicated on the coils (e.g. both are set to AC). 2. Should the two frequencies are different, move the jumpers [8] in order to select the same frequency as indicated on the coils. 3. Put the front panel back in place and fasten the 4 screws. 4. Close the transparent cover by means of the 2 screws [21] (optional). Never select 115 or 230 V/DC for output! aftersales@simatek.dk 6 Doc. No.: _EN

7 6.2 Parameters selection Make sure that all electrical connections have been carried out as described in paragraph 5. Switch on/off [1] on 1. LED WD [18] and LED Remote [16] are on. On the display [7] appears, for a few seconds, the Simatek identification code. Once the code disappears, the display will show the letter E (run) and the number of the valve which is going to be activated. 1) Press SELECT MENU [9]: The no. 1 will flash on the display [7]: Using +/ buttons [10] select Pulse Time ( sec). 2) Press SELECT MENU [9]: The no. 2 will flash on the display [7]: Using +/ buttons [10] select Pause Time (1-999 sec). 3) Press SELECT MENU [9]: The no. 3 will flash on the display [7]: Using +/ buttons [10] select Pause Time in Shut down cleaning (1-999 sec). 4) Press SELECT MENU [9]: The no. 4 will flash on the display [7]: Using +/ buttons [10] select the No. of cycles of Shut down cleaning (0-99). Select 0 if you don t wish to have Shut down cleaning. 5) Press SELECT MENU [9]: The display [7] will show the letter E (run) and the number of the valve which is going to be activated - the cleaning cycle starts. LED PULSE [11] will indicate that a valve is activated. LED PAUSE [12] will indicate that the Simatek is waiting to activate the next valve. NOTE! Valves are pulsed from output No. 1 onwards. The Simatek automatically skips any disconnected outputs, while showing the corresponding output numbers on the display [7] in quick sequence. If no valves are connected, the display will show the numbers of all the outlets in sequence. Check that during the first cleaning cycle every valve is activated. We suggest setting the Simatek working parameters to clean the filter at the lowest frequency possible, thereby reducing the little dust escape arising during jet-pulsing, achieving a longer lifetime of filter bags/cartridges and reducing the compressed air consumption. Pause time should allow an efficient filter cleaning in the worst conditions, but should never be shorter than the time needed to re-pressurise the compressed-air tank. While selecting parameters (Select menu), Simatek will return to normal operation if no buttons are pressed within a 5 minute interval. aftersales@simatek.dk 7 Doc. No.: _DK

8 7. Remote control NOTE Simatek fits the Simatek unit with a connection on terminals Remote [26] and Common [37]. If you wish to operate Simatek with a remote switch, read instructions below. If you do not wish to take advantage of this opportunity, do not remove the connection. To activate Remote: 1. Unscrew and remove the terminals cover [20]. 2. Remove the connection from terminals Remote [26] and Common [37]. 3. Bring an external no-load and normally open (NO) contact to Remote [26] and Common [37] terminals from an external device (e.g. contact from DP monitor). 4. Replace and screw the terminals cover tight [20]. 5. Close the contacts on the Remote [26] and Common [37] terminals in order to enable the Remote function. 6. Should you open the contact on Remote [26] and Common [37] the Simatek will stop working and LED Remote [35] and LED Pause [12] will be off. Close the contact in order to start the cleaning cycle again from the position where it stopped. 8. Shut down cleaning We suggest operating one or more cycles of Shut down cleaning at the end of each working session in order to remove the residual dust of the filter. Shut down cleaning is started each time the fan is switched off. In order to activate Shut down cleaning: 1. Select Pause Time and number of cycles of Shut down cleaning (see paragraph 6). 2. Unscrew and remove the terminals cover [20]. 3. Bring an external no-load and normally closed (NC) contact to terminals Fan [36] and Common [37] from the fan switch. 4. Replace the terminals cover [20] and tighten the screws. 5. Shut down cleaning starts as soon as the Fan is switched off, contact on terminals Fan [36] and Common is closed, and LED Shut down [33] flashes. NOTE: Should you have selected 0 at step 4 of paragraph 6.2, Simatek will stop working as soon as the contact on terminals Fan [36] and Common [37] is closed (LED Shut down [33] is on). 6. Once Shut down cleaning is completed, LED Shut down [33] will remain on. Switch the fan on in order to start cleaning cycle again. The cleaning cycle starts from the first valve. 9. Low pressure You can connect a pressure gauge contact to terminals Low Pressure [29]. When the contact is closed the unit will stop working. To activate Low Pressure: 1. Unscrew and remove the terminals cover [20]. 2. Connect an external pressure gauge contact to Low Pressure [29]. 3. Replace the terminals cover [20] and fasten the screws. 4. Set the pressure gauge at the minimum desired pressure value, when the pressure is lower the contact closes and the unit will stop working. aftersales@simatek.dk 8 Doc. No.: _EN

9 10. Short circuit alarm of the outputs The short circuit alarm is automatically activated by the Simatek (LED Alarm [17] is on) in order to signal failure of the solenoid/s. The Simatek will not activate the outputs in alarm, and will therefore exclude the faulty valves from the cleaning cycle. In order to identify the faulty valves: 1. Press the key + [10]: The display [7] will show the letter A followed by the number of the output in alarm. 2. Keep pressing the key + [10] in order to identify all of the outputs in alarm. 3. Press key - [10] to go back to E (run). 4. Perform the required maintenance. 5. Press Alarm reset [19]: The alarm is eliminated as the fault has been rectified. To have remote Alarm signal, connect to the relay s terminals on contacts All common [38] and No [39] or Nc [40]. 11. Microprocessor failure alarm LED WD [18] will switch off each time the microprocessor is faulty. The customer cannot solve the problem: contact Simatek. This will also activate the Alarm contact. aftersales@simatek.dk 9 Doc. No.: _DK

10 12. Troubleshooting Problem Probable cause Solution Display is blank and all LEDs are off. No power supply. Check the connections of the power supply terminals [4] and the selection of supply voltage. Display shows all the numbers of the outlets in quick sequence. No outputs connected. Check connection to the valves [2]. Some valves are ignored by the Simatek. Display shows the pulsing sequence but valves are not functioning. Wrong electrical connections between Simatek and coils. Coils are interrupted. The secondary of the transformer is interrupted. Power circuit is damaged. Check connections [2]. Check coils continuity. Contact Simatek Contact Simatek Supply voltage to valves is different from voltage indicated on the coils. LED WD [18] is off. Microprocessor failure. Contact Simatek. Move jumpers [6] and [6A] in order to select the same power supply as indicated on the coils. LED REMOTE [35] is off and Simatek is in block. The bridge on terminals Remote [26] has been removed. Contact on terminals Remote [26] has been opened. Replace the bridge on terminals [26]. Close the contact on terminals [26]. LED ALARM [17] is on. Short circuit on one or more outputs. See paragraph 10. IMPORTANT NOTE: Should the Simatek unit be powered with 24 V DC, make sure inlet supply voltage is not lower than 24 V, and that voltage is proportioned to connected loads. 13. Fuse table Dimension Value Type No. on drawing Description 5 x 20 1A T [23] Main fuse with 115/230 V supply 5 x 20 2A T [23] Main fuse with 24/48 V supply 5 x ma T [31] External contacts supply 5 x ma T [32] Internal +5V supply (micro, display) In case of replacement you must respect the values above. aftersales@simatek.dk 10 Doc. No.: _EN

11 14. Factory settings/program menu 14.1 Pulse time Simatek recommends a pulse time of 0.2 sec. Recommended pause times for SimPact 4T/4T-R filters 14.2 Pause time By continuous cleaning, the pause time is calculated from a total cleaning time for the filter of 180 sec. See recommended pause time by continuous cleaning for the current filter type Pause time Shut down cleaning The pause time during shut down cleaning may be set as required according to the properties of the dust in question, however, the pause time must be correspond to the compressor capacity Shut down cycles Bag cleaning will continue during the set number of cycles (first valve to last valve) after connection between Fan [36] and Common [37], (fan stopped). Any equipment for removal of the separated dust should run during shut down cleaning. Simatek recommends 2-3 cycles, as the current cycle is regarded as the first shut down cycle. Therefore the first cycle will not necessarily be a full cycle. aftersales@simatek.dk 11 Doc. No.: _DK

12 15. Legend [1] On/off switch [2] Push in valves terminals [3] Valve earthing [4] Power supply terminals [5] Jumper for inlet supply voltage selection [6] Jumper for voltage selection to valves [6A] Jumper for voltage selection to valves [7] Display [8] Jumper for frequency selection to valves [9] Push button Select Menu [10] Push buttons +/- [11] LED Pulse [12] LED Pause [15] LED Low pressure [17] LED Alarm [18] LED WD (watch dog) [19] Push button Reset [20] Terminals cover [21] Transparent cover fixing screws (optional) [22] Yellow label indicating IN/OUT voltage frequency [23] Fuse [24] Relay terminals [25] Product code and serial number [26] Terminals Remote [29] Terminal Low pressure [31] External contacts supply fuse [32] Internal +5V supply (micro, display) [33] LED Shut down [35] LED Remote [36] Terminals Fan [37] Common terminal [38] Alarm common terminal [39] Alarm No terminal [40] Alarm Nc terminal 12 Doc. No.: _EN

13 16. Simatek :20: General assembly 13 Doc. No.: _DK

14 17. Electric diagram for Simatek : 20 valves aftersales@simatek.dk 14 Doc. No.: _EN

15 18. Declaration of Conformity 15 Doc. No.: _DK

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

Manual Control Unit GFCD 16

Manual Control Unit GFCD 16 Manual Control Unit 1400002_EN/04.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Filter taps 5 7. Settings 6 8.

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying

More information

SEQUENCER FOR DEDUSTING PLANTS

SEQUENCER FOR DEDUSTING PLANTS BB SEQUENCER FOR DEDUSTING PLANTS PLEASE READ THE WHOLE USER MANUAL CAREFULLY BEFORE INSTALLING THE EQUIPMENT 1. ENTER DATAS IN SET MODE 1. Press key C to have access to the function menu F01 F13. 2. Press

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Operating and Maintenance Instructions

Operating and Maintenance Instructions Part No Description Dual EC Fan Controller Issue Date Bug no Comments 1 10 July 2012 1205 Signed CE front sheet & instructions clarified 2 28 Jan 2013 1205 Instructions clarified, identify Live & SELV

More information

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.: Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: BLDA-1 & 2 Water Leak Detection Manual CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 Contents 1) System Overview 2) Installation 3) Wiring 4) Water

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-RO8 and IO-DI8-RO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

AL168 Series Multi-Output Power Supplies

AL168 Series Multi-Output Power Supplies AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @

More information

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34 Vision OPLC V130-33-TR34/V130-J-TR34 V350-35-TR34/V350-J-TR34 V430-J-TR34 V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Installation Guide 22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Vision OPLC V TR20/V350-J-TR20

Vision OPLC V TR20/V350-J-TR20 Vision OPLC V350-35-TR20/V350-J-TR20 Installation Guide The Unitronics V350-35-TR20/V350-J-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, and 3

More information

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down) Data sheet Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN 14597 certified safety function (spring down) Description AME 10 AME 13 AME 20, AME 30 AME 23, AME

More information

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch Manual Supplement 00809-0200-400, Rev AA July 2005 Rosemount 220 Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 220 Vibrating Fork Liquid Level Switch Refer to the Rosemount

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30

More information

ELV12 Series. Instruction Manual

ELV12 Series. Instruction Manual Instruction Manual TDK-Lambda BEFORE USING POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all warnings and cautions before using the unit.

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Control D. Controller Module for Proportional Valve Control. Installation Manual

Control D. Controller Module for Proportional Valve Control. Installation Manual Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

EWCH 485 Electronic Pulse Counter

EWCH 485 Electronic Pulse Counter Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:

More information

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Screen 2.4 3.5 Color Touch 4.3 Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed V130-33-TR20/V130-J-TR20 V350-35-TR20/V350-J-TR20 V430-J-RH2 Installation Guide 12 Digital Inputs, including 2 Analog, 3 HSC/Shaft-encoder inputs 6 Relay Outputs 2 high-speed npn Transistor Outputs (TR20

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

User safety and equipment protection guidelines

User safety and equipment protection guidelines Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital

More information

Type Quickstart

Type Quickstart Type 8605 Digital Control Electronics for Proportional Valves Digitale Ansteuerelektronik für Proportionalventile Régulateur électronique numérique pour vannes proportionnelles Quickstart Contents 1 Quickstart...

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Operating Instructions Differential Pressure Transducer PS27

Operating Instructions Differential Pressure Transducer PS27 Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Component identification

Component identification IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that

More information

Vision OPLC. V T38 Installation Guide. General Description

Vision OPLC. V T38 Installation Guide. General Description Vision OPLC V130-33-T38 Installation Guide The Unitronics V130-33-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs 16

More information

Chameleon Stand-alone

Chameleon Stand-alone Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

This guide provides basic information for Unitronics controller model V T2.

This guide provides basic information for Unitronics controller model V T2. Vision OPLC 12 pnp/npn Digital, including 2 Analog, 3 HSC/Shaftencoder Inputs, 12 Transistor Outputs This guide provides basic information for Unitronics controller model V350-35-T2. General Description

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X Instruction Manual Electrical Management System (EMS) EMS-PT30X & EMS-PT50X EMS-PT50X EMS-PT30X 2 ProgressiveIndustries.net 919-267-6964 Features High/Low Voltage Protection: The EMS continuously monitors

More information

EC Series. Safety Guide

EC Series. Safety Guide EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

V TU24 V350-J-TU24

V TU24 V350-J-TU24 Vision PLC+HMI V350-35-TU24 V350-J-TU24 Installation Guide 12 Digital Inputs, including 2 Analog, 2 PT100/TC,1 HSC/Shaft-encoder input 12 Transistor Outputs General Description All of the controllers covered

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Vision OPLC V350-35-B1/V350-J-B1 Installation Guide The Unitronics V350-35-B1/V350-J-B1 offers the following features: I/O configurations can be added via Expansion Modules. General Description V350 OPLCs

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Fog machine PT Users Manual

Fog machine PT Users Manual Fog machine PT-1500 Users Manual Table of content 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Intended use of the device... 4 2.1. Overhead installation... 5 2.2. Electrical

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information