Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12
|
|
- Clinton Hudson
- 5 years ago
- Views:
Transcription
1
2 01-02 Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU How to install
3 Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U Safewell Basic PDU have modularized structure that can be manufactured according to customer's technical requirements. Strictly designed according to international standard and have been awarded invention patent. Internationally leading technology, original and novel structure, safe and reliable quality, easy installation and wide use. Mainly applicable to 19'' standard and nonstandard cabinet. Input voltage is 110VAC, 220VAC and 380VAC, output voltage is 110VAC and 220VAC. The maximum load current can reach 10-36A and above. All Safewell PDU were checked one by one, Each series are all with CE and RoHS certification. Technical Input current Mounting method Material Cable size 16A Horizontally mounting to standard 19 cabinet Aluminium alloy 2m*1.5mm² Outlet connector (8) IEC 320 C14 16A connector Input connector ICE 320 C14 16A connector Control/ Protective Control Others One package contains 4pcs mounting screw sets Specification Features Outlet Options Control function Module Protective Function Module Size(Width) NEMA-5-15; NEMA 5-20; IEC 320C13; IEC 320 C19; Schuko DIN49440; French NFC61-314; Italy universal; Denmark SB D1; Switzerland SEV 1011; Israel SI32;South Africa INDIA SOCKET; Australia AS/NZS 3112 ON/OFF Switch; 1P circuit breaker; 2P circuit breaker;power indicator; Overload protect module Surge Protective Device; 3 lights Protective device; Voltage and current meter; Current meter. 1U;1.5U Horizontal 19" rack mountable, Vertical suitable for rack mounting. Left hand with different kinds power input. CE Approved. RoHS compliant. Various countries plug/socket types available, including:britain, American, Germany, IEC,etc. Master on/off switch. Optional circuit breaker. Black plastic and aluminum body. Input Power Options International 230V, 16A/32A; 110V 16A/32A Material Aluminum; SPCC;Plastic Maximum Outlets Basic: 45 Maximum Operating Temp. Range 0 C to 55 C Storage Temperature Range -25 C to 85 C Relative Humidity 5% to 95% 1 Mounting method Agency Approvals Parameters Measured Toolless brackets; Universal Mounting bracket; Ability to ship rack PDU pre-installed in Safewell Racks CE;RoHS Volts, Current 2
4 Control Function Module Protective Function Module Double Break Switch Module Switch with power light can cut off the neutral and live wires at the same time,to avoid danger from mis-connecting in circuit check or repair SPD Surge Excluder Surge protector provides protection against instantaneous current up to 10,000 amperes with booting time less than one microsecond and nominal discharge current 8/20us. Top surge master not only prevents injury caused by lightning strike and various types of surge phenomenon during daily power-supply, but also can prevent effective protection at every moment against different surge intrusion. Overload Protective Module V/A Meter Possess safety certificate of good quality, senstive overload protective devices and is flexible, reusable,convenient and safe. When overload is excluded, you can reset the device to resume power supply. Can show the aggregate current timely, it monitors the circuit at any moment to avoid overload. Air Proctective Control Module 3 in 1 Protective Module 1P or 2P circuit breaker.cuts-off and carries working current of the circuit,when there is overload, short circuit or overvoltage it provides the most reliable protection to ensure the safety of circuit and power,related standard air protective switch regarding highpower environment with automatically devices. 1.Surge protective function 2.Wave filtering function 3.Power instruction, operation instruction and earthing instruction. Single Power Indicator Power instruction, inspect whether the electric circuit is work or not and PDU operate normally. 3 4
5 SW Meter PDU Model: SW-M-8IECC13 Electrical Specification Input connector Output connector Overload protection Max output current (outlet) Max output current (Branch) Nominal input voltage Acceptable input voltage Max Power Input Frequency Sensor Interface Console Interface Ethernet Interface Height Width Depth IEC 320 C20 16A connnector (8) IEC 320 C13 No breaker 10A IEC 320 C13 16A 100 VAC ~ 240 VAC ± 10% of nominal voltage 3.84kVA 47-63Hz RJ11 RJ45 RJ mm mm mm Features View parameters over remote IT assets from anywhere on earth; Outlet level power meter, including Current /Voltage /Apparent Power /Active Power /Power Factor /Frequency /Consumption with 1% precises; External environment sensor of temperature and humidity; Configurable thresholds, and send fault notification via , SNMP trap and SYSLOG; Outlet level power cost, carbon emission and power saving calculation.; Users privilege management; Ethernet & console CLI management; Support HTTP, HTTPS, TELNET,SSH, SNMP etc, and service enable/disable; Support DHCP, NTP, SYSLOG, FTP, etc; Support NMS(Network Management Server) with topology, alerts, logs, privilege management and dashboards; Safely upgrade without interrupting power output; APP monitoring. Net Weight 2.5 KG Range & Precise Working Range Meter Range Precise Distinguishability Temperature( C ) 0~55 0~70 ±0.2 C 0.1 Humidity(%RH) 20~90 1~99 ±2%RH 0.1 Current(A) 0~Rated 0.01~ Rated ±1% Voltage(V) 100~240VAC 50~265VAC ±1% 0.1 Apparent Power (VA) 0~Rated 0~Rated ±1% 0.1 Active Power(W) 0~Rated 0~Rated ±1% 0.1 Power factor 0~1 0~1 ±1% Frequency(Hz) 50/ Power Consumption(kWh) ±1%
6 SW Meter-Switch PDU Model: SW-M-S-8IECC13-4IECC19 Electrical Specification Input connector Output connector Overload protection Max output current (outlet) Max output current (Branch) Cord length Nominal input voltage Acceptable input voltage Max Power Input Frequency Sensor Interface Console Interface Ethernet Interface Height Width Depth Net Weight IEC 309 P+N+E 16A connector (8) IEC 320 C13 +(4) IEC 320 C19 (1) 16-A 1P breaker 10A IEC 320 C13, 16A IEC 320 C19 16A 2.0m 2.5mm²*3 100 VAC ~ 240 VAC ± 10% of nominal voltage 3.84kVA 47-63Hz (1) RJ mm mm mm 4.0 KG Features Power control over remote IT assets from anywhere on earth; Outlet level power meter, including Current /Voltage /Apparent Power /Active Power /Power Factor /Frequency /Consumption with 1% precises; External environment sensor of temperature and humidity; Configurable thresholds, and send fault notification via , SNMP trap and SYSLOG; Outlet level power cost, carbon emission and power saving calculation.; Users privilege management; Ethernet & console CLI management; Support HTTP, HTTPS, TELNET,SSH, SNMP etc, and service enable/disable; Support DHCP, NTP, SYSLOG, FTP, SMTP, etc; Support NMS(Network Management Server) with topology, alerts, logs, privilege management and dashboards; Safely upgrade without interrupting power output; APP monitoring. Range & Precise Working Range Meter Range Precise Distinguishability Temperature( C ) 0~55 0~70 ±0.2 C 0.1 Humidity(%RH) 20~90 1~99 ±2%RH 0.1 Current(A) 0~Rated 0.01~ Rated ±1% Voltage(V) 100~240VAC 50~265VAC ±1% 0.1 Apparent Power (VA) 0~Rated 0~Rated ±1% 0.1 Active Power(W) 0~Rated 0~Rated ±1% 0.1 Power factor 0~1 0~1 ±1% Frequency(Hz) 50/ Power Consumption(kWh) ±1%
7 SW Three Phase PDU Data Sheet SW Three Phase PDU Model: SW-M-TP36IECC13 Electrical Specification Input connector Output connector Overload protection Max output current (outlet) Max output current (phase) Cord length Nominal input voltage Acceptable input voltage Max Power Input Frequency Sensor Interface Console Interface RS485 Interface ExT Interface Ethernet Interface Height Width Depth Net Weight IEC 309 3P+N+E 32A connector (36) IEC 320 C13 (3) 32-A single-pole breakers 10A IEC 320 C13 32A ft (3.05m) 220VAC, 3-phase ± 10% of nominal voltage 23.04kVA 47-63Hz (3) RJ11 (2) RJ mm mm mm 7.5 KG Range & Precise Features Working Range Meter Range Precise Distinguishability Temperature( C ) 0~55 0~70 ±0.2 C 0.1 View parameters over remote IT assets from anywhere on earth; Branch level power meter, including Current /Voltage /Apparent Power /Active Power /Power Factor / Frequency /Consumption with 1% precises; External environment sensor of temperature and humidity; Configurable thresholds, and send fault notification via , SNMP trap and SYSLOG; Branch level power cost, carbon emission and power saving calculation.; Users privilege management; LCD display; Ethernet & console CLI management; Support HTTP, HTTPS, TELNET,SSH, SNMP etc, and service enable/disable; Support DHCP, NTP, SYSLOG, FTP, etc; Support NMS(Network Management Server) with topology, alerts, logs, privilege management and dashboards; Safely upgrade without interrupting power output; APP monitoring. 9 Humidity(%RH) 20~90 1~99 ±2%RH 0.1 Current(A) 0~Rated 0.01~ Rated ±1% Voltage(V) 100~240VAC 50~265VAC ±1% 0.1 Apparent Power (VA) 0~Rated 0~Rated ±1% 0.1 Active Power(W) 0~Rated 0~Rated ±1% 0.1 Power factor 0~1 0~1 ±1% Frequency(Hz) 50/ Power Consumption(kWh) ±1%
8 How to Install the Rack PDU Mounting Bracket Options How to Install the Rack PDU Mounting options You can install the Basic Rack PDU in one of two ways: using toolless mounting pegs (provided) or the vertical-mounting brackets (provided). To install the Basic Rack PDU using the toolless mounting method, install it in the rear of the Safewell SSG series server rack, in the cable channel directly behind the rear vertical- mounting rails. To install the Basic Rack PDU using the mounting brackets, install it on a vertical- mounting rail in the rack or enclosure.mounting brackets, install it on a vertical-mounting rail in the rack or enclosure. 3 Toolless Mounting Bracket mounting To mount the Rack PDU vertically in standard SSG rack or enclosure: 1. Attach the vertical-mounting brackets to the Rack PDU, using four M6*8 screws per bracket. 2. Attach the PDU to a vertical-cable management in the rear of the enclosure using two additional screws per bracket (not provided). Bracket and Accessories Toolless mounting 1. Slide both mounting pegs into the holes located in the cable channel in the rear panel of the enclosure. 2. Snap the Rack PDU into place by pushing it downward until it locks into position. You can mount two PDUs on each side of the enclosure by using the toolless mounting method Note
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationPDU Solutions. PDU Solutions
Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More information5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA
Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationECO PDU Power Distribution Unit
ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationCS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)
CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationCS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)
CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationStripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...
Stripes 19" Outlet Stripes... 90 Desktop Outlet Stripes... 93 IP Power Distribution Units... 94 IP Monitoring Units... 95 UPS... 96 19" Outlet Stripes DIGITUS 19" outlet strip with switch, 7 outlets DIGITUS
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationInnovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s
Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power
More information8-Outlet eco PDU PE6208AV
8-Outlet eco PDU Ideal for CI and Pro-AV applications, the ATEN NRGence eco PDU is an intelligent 1U rack PDU that contains 8 AC outlets available in an IEC socket configuration. The unique design with
More informationPDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions
PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the
More informationPE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
More informationOPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES
OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,
More informationSmart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V
Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V APC Smart-UPS, 480 Watts / 750 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 1 U Includes: CD with software,
More informationSmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial
SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial MODEL NUMBER: SU1500RTXL2UN Highlights 1500VA / 1.5kVA / 1200
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 6. Specifications... 8 1. Introduction The ServerLink PDU is a network
More informationCS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)
CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More informationThe -3Ph extension on a product indicates a 3 Phase power product.
Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationNeutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A
PDU16-AV 20A AC PDU WITH POWER MONITOR 2U Rack Mount PDU with Overload Protection & Power Monitoring 2U high Horizontal Mounting unit designed to provide versatile hook-up for the distribution of AC power
More informationPOWER DISTRIBUTION UNITS
POWER DISTRIBUTION UNITS Efficient and safe power distribution for information systems and datacenters POWER DISTRIBUTION UNITS > THE SOLUTION Power distribution units Eurolan s extensive product range
More informationSmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationECO PDU PE7108/PE7208
PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent
More information6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable
6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect
More informationModels. Specifications
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors
More informationLiebert MPH TM Managed Rack-PDU Systems monitoring and control
Liebert MPH TM Managed Rack-PDU Systems monitoring and control The Liebert MPH TM Managed Rack PDU is a power supply system with monitoring and control functions. The housing consists of a robust sheet
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationSLI 15 INVERTER SERIES, 1500 W
SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with
More informationECO PDU PE5108/PE5208
1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationUninterruptible Power Supplies
Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA
More informationG GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44
More informationSmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial MODEL NUMBER: SMART750RM1UN Highlights.75kVA / 750VA / 600W line interactive
More informationSwitched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5
More informationBack-UPS RS APC Back-UPS RS 800VA 120V Black
Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationIBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide
IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationSwitched, Outlet Level Monitoring
Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on
More informationCAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. TM Introducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors of
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed
More informationMODEL NUMBER: SMART3000RMXLN. Highlights. Package Includes. Description
SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, LCD Display, USB, DB9 Serial MODEL NUMBER: SMART3000RMXLN Highlights 3kVA
More informationSmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9
SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9 MODEL NUMBER: SU3000RTXLCD3N Highlights Zero transfer time suitable for advanced
More informationIT PDU. PULTI Solution for computer rack equipment
IT PDU PULTI Solution for computer rack equipment 1 2 ELECTRICAL INSTALLATION SYSTEM PULTI the 19 housing reference in Europe Information and communication technologies (IT) bring together the techniques
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationYourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.
This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. Your PDU 3..7 1. 2. Our advanced technology offers you accurate measurements and detailed data, so that
More informationQuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview
Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationManaged Rack PDU MPH2 More efficient Simpler Better
Managed Rack PDU MPH2 More efficient Simpler Better MPH2 Managed Rack PDU The newly developed Managed Rack PDU MPH2 TM is a power supply system with monitoring and control functions. Standout features
More informationSmart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out
Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out APC Smart-UPS, 1600 Watts / 2200 VA,Input 120V, 230V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, Rack Height 3 U Includes: CD with software,
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationipdu Pocket Guide NORTH AMERICA
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide NORTH AMERICA Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationSymmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,
More informationAVR Series 230V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port, French/Belgian Outlets
AVR Series 230V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port, French/Belgian Outlets MODEL NUMBER: AVRX750UF Highlights 750VA ultra-compact 230V line interactive UPS Corrects brownouts and
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationSymmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,
More informationSmart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V
Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V APC Smart-UPS XL, 1850 Watts / 1850 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB, SmartSlot, Extended runtime model, Rack Height 3 U Includes:
More information550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure
550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset
More informationQuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview
HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching
More informationIBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide
IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter
QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.
More informationIBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation
IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units 10/9/2007 Agenda System x Options Program and PDU market overview What is a PDU? Why do you need an IBM DPI PDU? IBM DPI PDU offering
More informationModular PDU Smart metering for your IT
Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With
More informationVFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative
VFI RTG PDU 6-10K Installation and user manual Service and support: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that
More informationInstallation Manual for D1800 Series High Power PoE Midspan Power Supply
Installation Manual for D1800 Series High Power PoE Midspan Power Supply Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A - Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com
More informationPN5212/PN5320/PN7212/PN7320
PN522/PN520/PN722/PN720 Power Over the NET Power Distribution Units ALTUSEN Power Over the NET products are Power Distribution Units that offer outlet level control combined with remote access to give
More informationDisclaimer. Note that the Midspan is designed for indoor use only.
Gigabit Power over Ethernet Midspans PD-6006G, PD-6012G & PD-6024G 6/12/24-Port Models IEEE 802.3af-compliant User Guide Notice The information contained herein is believed to be accurate and reliable
More informationSmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets
SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets MODEL NUMBER: SU20KRT-1TF Description Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt
More informationPowerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)
Powerstar PS3204rm2u PS3204 tower (120V) 3.4 H x16.9 W x19.7 D 85 x 430 x 497mm Model upgrade from PS3200 (GXT2) and PS3203 (GXT3)- now using Liebert GXT4 electronics Double Conversion true online type
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationServer Specifications
, page 1 Power Cord s, page 6 This appendix lists the physical, environmental, and power specifications for the server. Physical s, on page 1 Environmental s, on page 2 Power s, on page 2 Physical s The
More informationApplication. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:
Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this
More informationE-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual
NTI R NETWORK 1275 Danner Dr Tel:330-562-7070 TECHNOLOGIES Aurora, OH 44202 Fax:330-562-1999 INCORPORATED www.networktechinc.com ENVIROMUX Series E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation
More informationSmart-UPS APC Smart-UPS 2200VA USB & Serial 120V
Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V APC Smart-UPS, 1980 Watts / 2200 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB, SmartSlot Includes: CD with software, Smart UPS signalling
More informationSmart-UPS APC Smart-UPS 1500VA USB & Serial 120V
Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V APC Smart-UPS, 980 Watts / 1440 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationProduct Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators
Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators Good. Great. GUDE. v2.5.5 Product Catalogue of Gude Analog- und Digitalsysteme Dear customer, Koeln, January
More informationSmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9
SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9 MODEL NUMBER: SMX3000XLRT2UA Highlights 3kVA / 3000VA / 2700W line interactive 2U rack/tower
More informationRM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases
Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching
More informationUser Guide Automatic Transfer Switch (ATS)
User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...
More informationPOWER DISTRIBUTION UNITS (PDUs)
P R O D U C T D ATA S H E E T POWER DISTRIBUTION UNITS (s) for CPI Rack and Cabinet Systems K E Y F E AT U R E S Distribute power to multiple devices from a single power connection NEMA, California Style
More informationRCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers
More informationSmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets
SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets MODEL NUMBER: SMART1500RM2UN Highlights Corrects under- and overvoltages from
More information