Technical features OVR Surge Protective Devices Type 1 & Type 1+2
|
|
- Harry Jones
- 5 years ago
- Views:
Transcription
1 Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC / EN Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L 1P+N 1N 3P+N 3N Types of networks IT - TNS TNS-TNC TNC TNS TT - TNS TT - TNS Type of current A.C. Nominal voltage Un (L-N/L-L) V / / /400 Max. cont. operating voltage Uc V Max. cont. operating voltage Uc (L-N / N- ) V / 2 2 / 2 Impulse current Iimp (10/30) per pole ka Impulse current Iimp (10/30) (L-N / N- ) ka / 0 2 / 100 Imax discharge current (8/20) per pole (Imax) ka Imax discharge current (8/20) (L-N/N-terre) (Imax) ka Nominal discharge current In (8/20) ka Voltage protection level Up kv Voltage protection level Up (L-N / N- ) kv / 2 2. / 2 Follow current interrupting rating If i karms Follow current interrupting rating If i (L-N / N- ) karms / / 0.1 TOV (Temporary overvoltage) withstand U T (s.) V TOV (Temporary overvoltage) withstand U T (L-N: s. / N- : 200ms.) V / / 1200 Continuous operating current Ic ma None Short-circuit withstand capability karms 0 Load current I load (for V-wiring) A 12 Maximum back-up fuse gg/gl - Parallel Connection A 12 Serial Connection (V-wiring) A 12 Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V0 Colour of Housing Polyarylamide grey RAL 703 State indicator Option (with TS) TS remote indicator Option (TS) Wire range (L, N, ) solid wire mm stranded wire mm Stripping length (L, N, ) mm 1 Tightening torque (L, N, ) Nm 3. TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features Contact complement 1NO (1 normally open contact), +1NC (1 normally closed contact) Min. load 6 V D.C ma Max. load 20 V A.C. - A Continuous operating current ma 10 Connection cross-section mm 2 1. /2 ABB
2 Type 1 & Type 1+2 Type 1 Type1+2 Type 1+2 Type 1+2 OVR T OVR T TS OVR T OVR T s P Triggered spark-gap Triggered spark-gap/varistor Triggered spark-gap Varistor IEC / EN IEC / EN IEC / EN IEC / EN / I 1/ I 1 / I 1 / I 1P - 3P+N 3N 1P - 3P+N 3N 1P - 3P 3L 4P 4L 1P+N 1N 3P+N 3N TNS-TNC TT - TNS TNS - TNC TNS-TNC TT - TNS TNS-TNC TNC TNS TT - TNS TT - TNS A.C. A.C. A.C. A.C. 230/ / / / / / 2-2 / / / / 0-7 / / /70 70/ / / / / NA / / NA / 0.1 NA / / / / 1200 < 2 (LED) < 1 (Varistor leakage) < 2 (LED) < NA 12 NA NA -40 to to to to +80 IP 20 IP 20 IP 20 IP 20 V0 V0 V0 V0 Polyarylamide grey RAL 703 Polyarylamide grey RAL 703 Polyarylamide grey RAL 703 PC grey RAL 703 Yes Yes Yes Yes No Yes No No NO (1 normally open contact), NC (1 normally closed contact) - 12V D.C ma V A.C. - 1 A None ABB /3
3 Type 2 TECHNICAL FEATURES Technology Type 2 (pluggable) OVR T2 (s) P (TS) Varistor Electrical features Standard IEC / EN Type / test class 2 / II Poles 1P - 3P 3L 4P 4L 3P+N 3N 1P - 3P3L 4P4L 1P+N 1N 3P+N 3N Types of networks IT - TNS IT* IT TT - TNS TNS-TNC TNC TNS TT-TNS TT-TNS Type of current A.C. A.C. A.C. A.C. A.C. Nominal voltage Un (L-N/L-L) V / / /400 Max. cont. operating voltage Uc V Max. cont. operating voltage Uc (L-N / N-PE) V / 2-27 / 2 Max. cont. operating voltage Ucpv V Maximum discharge current Imax (8/20) per pole ka Maximum discharge current Imax (8/20) (L-N / N-PE) ka 1 /70 40 /70 70 / /70 40 /70 70 /70 Nominal discharge current In (8/20) ka Nominal discharge current In (8/20) (L-N / N-PE) ka /30 20/30 30/ /30 20/30 30/30 Voltage protection level Up kv Voltage protection level Up (L-N / N-PE) kv 1./ /1.4 2/ / /1.4 1./1.4 Residual voltage Ures at 3 ka per pole kv Residual voltage Ures at 3kA (L-N / N-PE) kv 1.4/ / / / / /1.2 Follow current interrupting rating If i karms NA NA - NA - Follow current interrupting rating If i (L-N / N-PE) karms - - NA / NA / 0.1 TOV (Temporary overvoltage) withstand Ut (s.) V TOV (Temporary overvoltage) withstand Ut (L-N: s./n-pe: 200ms) V / / 1200 Continuous operating current Ic ma < 1 < 1 < 1 < 1 < 1 Short-circuit withstand capability karms Short-circuit D.C. current withstand capability Iscwpv A Disconnector gg -gl fuse A curve C circuit breaker A Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V0 Material of Housing PC grey RAL 703 Pluggable cartridge Yes Integrated thermal disconnector Yes State indicator Yes Safety reserve Option (s) TS remote indicator Option (TS) Wire range (L, N, ) solid wire mm stranded wire mm Stripping length (L, N, ) mm 12. Tightening torque (L, N, ) Nm 2.8 TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features Contact complement 1NO (1 make contact), +1NC (1 normally closed contact) Min. load 12V D.C ma Max. load 20V A.C. - 1 A Continuous operating current ma None Connection cross-section mm 2 1. /4 ABB
4 Type 2 Type 2 (non pluggable) Type 2 (non pluggable) OVR Plus N1 40 OVR Plus N3 1 OVR Plus N3 40 OVR T2 27 Varistor IEC / EN EN , IEC EN , IEC IEC / EN / II T2/II T2/II 2 / II 1P+N N P - 4P 4L TT - TNS TT-TNS TT-TNS TNS - TNC TNS A.C. A.C. A.C. A.C. 230/ / / / / 40 1/60 40/ /40 20/ / /1. 2/ / /1 1.1/1 - - NA - - NA / / < 1 <0.1 <0.1 < Integrated MCB Integrated MCB Integrated MCB to to +80 IP 20 IP 20 V0 V0 PC grey RAL 703 PC grey RAL 703 No No No No Yes Yes Yes Yes Yes (MCB) Yes (MCB) Yes (MCB) Yes No No No No Optional (S2C-H6R) Optional (S2C-H6R) Optional (S2C-H6R) ABB (2CDS200912R0001) ABB (2CDS200912R0001) ABB (2CDS200912R0001) No ,8 2,8 2,8 ABB /
5 Type 2 NEW TECHNICAL FEATURES Type 1 Photovoltaic OVR PV T1 6.2 xx P TS Technology Varistor Electrical features Standard IEC / EN / UTE / pren Type / test class T1/I Poles 9 Types of networks Photovoltaic Type of current V D.C. Nominal voltage Un (L-N/L-L) V Max. cont. operating voltage Uc V - - Max. cont. operating voltage Ucpv V Impulse current Iimp (10/30) per pole ka 6,2 6,2 Maximum discharge current Imax (8/20) per pole ka - - Nominal discharge current In (8/20) ka 6,2 6,2 Voltage protection level Up kv 1.9 / / 2. Follow current interrupting rating Ifi ka - - TOV (Temporary overvoltage) withstand Ut (s.) V - - TOV (Temporary overvoltage) withstand Ut (L-N: s./n-pe: 200ms) V - - Response time ns <2 <2 Series resistance Ω - - Cut frequency MHz - - Continuous operating current Ic ma <0.1 <0.1 Short-circuit withstand capability ka - - Short-circuit D.C. current withstand capability Iscwpv A 100 Disconnector If Iscwpv>100A fuse A 10AgPV (E90PV) circuit breaker A - - Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 VO Material of Housing PC grey RAL 703 Pluggable cartridge No No Integrated thermal disconnector Yes Yes State indicator Yes Yes Safety reserve No No TS remote indicator Yes Yes Wire range (L, N, ) solid wire mm² 2. 2 stranded wire mm² Stripping length (L, N, ) mm 12,2 12,2 Tightening torque (L, N, ) Nm 2, 2, TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features 1 NO - 1 NC 1 NO - 1 NC Contact complement Min. load 12 V DC - 10 ma 12 V DC - 10 ma Max. load 20 V AC - 1 A 20 V AC - 1 A Connection cross-section mm² 1, 1, /6 ABB
6 Type 2 Type 2 Photovoltaic OVR PV 40 xx P (TS) Telecom / Dataline OVR TC xx V P Varistor IEC / EN / UTE / pren IEC T2/II C2 3 1 pair Photovoltaic RS RS 232 4/20 ma RNIS ADSL ADSL 422/48 D.C. D.C FR <2 <2 <1 < na na <0.0 < na If Iscwpv>100A 10AgPV (E90PV) - S802PV-S10 S804PV-S to +80 IP 20 VO PC grey RAL 703 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - Yes Yes - No No No No No No No No Yes (TS option) Yes (TS option) No No No No No No , ,2 12,2 7 2, 2, 0,4 1 NO - 1 NC 1 NO - 1 NC V DC - 10 ma 12 V DC - 10 ma - 20 V AC - 1 A 20 V AC - 1 A - 1, 1, - ABB /7
7 Selection tables T1 2CSC400313F0201 2CSC400313F0201 2CSC400316F0201 2CSC40031F0201 2CSC40031F0201 2CSC400306F0201 Surge Protective Devices, Type 1 / Type 1+2 Function: Type 1 and Type 1+2 are Lightning Current Arresters. They can handle and divert high energy from lightning. They are necessary when the installation is exposed to direct lightning (for example when the building is equipped with external lightning protection system or powered by aerial lines). They shall be installed at the line entrance of the installation (meter board or main distribution board). ABB Type 1 and Type 1+2 are tested with wave-shape 10/30. Additionnaly, Type 1+2 are also tested with wave-shape 8/20 to guarantee protection against overvoltage of low energy from remote lightning stroke or from switching operations. ABB Type 1+2 feature a better voltage protection level (Up) than Type 1 which make them suitable for protection of most of electrical and electronic equipment. Type 1 Neutral are for TT networks when used in combination with phase Type 1 or Type 1+2. Application: residential, commercial, industrial Standard: IEC / EN /30 current wave for Type 1, 10/30 & 8/20 for Type 1+2, spark-gap technology (no blow-out). Nb. of Impulse Follow Voltage Nominal Max. cont. Order Bbn Price Price Weight Pack poles current current protection voltage operating details piece group 1 piece unit Iimp interrupting level voltage (10/30) If i Up Un Uc ka karms kv V V Type code Order code EAN kg pc. Type 1 (Ifi = 0 ka) TNS, TNC OVR T CTB81101R IT, TNC OVR T CTB81101R TNS 2 2 (2) OVR T1 2L 2 2 2CTB81101R (2) OVR T1 2L 2 2 TS (3) 2CTB81101R TT (1 Ph+N), TNS 1+N 2/0 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 1N 2 2 2CTB81101R N 2/0 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 1N 2 2 TS (3) 2CTB81101R TNC 3 2 (2) OVR T1 3L 2 2 2CTB81101R (2) OVR T1 3L 2 2 TS (3) 2CTB81101R TNS 4 2 (2) OVR T1 4L 2 2 2CTB81101R (2) OVR T1 4L 2 2 TS (3) 2CTB81101R TT (3 Ph+N), TNS 3+N 2/100 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 3N 2 2 2CTB81101R N 2/100 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 3N 2 2 TS (3) 2CTB81101R (1) L-N / N-. (2) per pole. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ /8 ABB
8 Selection tables T1 2CSC400297F0201 Nb. of Impulse Follow Voltage Nominal Max. cont. Order Bbn Price Price Weight Pack poles current current protection voltage operating details piece group 1 piece unit Iimp 7% level voltage (10/30) If i Up Un Uc ka karms kv V V Type code Order code EAN kg pc. Type 1 (Ifi = 7 ka) TNS, TNC 2CSC400299F OVR T CTB81101R TT (3 Ph+N), TNS 3+N 2/100 (1) 7/0.1 (1) 2./1. (1) 230 2/2 (1) OVR T1 3N CTB81101R OVR HL (Type 1 with varistors) T1+T2 1N 4L T1 (N+PE) 2CSC400306F0201 2CSC400299F0201 2CSC400299F0201 2CSC400297F0201 2CSC400300F0201 2CSC400299F0201 TT, TNS, TNC, IT 1 1 NA OVR HL s P TS 2CTB81201R NA OVR HL 2L s P TS 2CTB81303R Type 1+2 (Iimp = 2 ka) TNS, TNC OVR T TS (3) 2CTB81101R Type 1+2 (Iimp = 1 ka) TNS, TNC OVR T CTB81101R TT (3 Ph+N), TNS 3+N 1/0 (1) 7/0.1 (1) 1./1. (1) 230 2/2 (1) OVR T1+2 3N CTB81101R Type 1+2 (Iimp = 7 ka) OVR T s P 2CTB81101R / OVR T1+2 1N 7 27s P 2CTB81302R / OVR T1+2 3N 7 27s P 2CTB8102R OVR T1+2 3L 7 27s P 2CTB81101R OVR T1+2 4L 7 27s P 2CTB81101R OVR T s C 2CTB81101R OVR T NC 2CTB81101R Type 1 Neutral For TT networks when used in combination with phase Type 1 or Type < OVR T1 2 N 2CTB81101R OVR T1 0 N 2CTB81101R OVR T1 100 N 2CTB81101R (1) L-N / N-. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. Bus bar For TT (3Ph+N) networks, this bus bar can be used to connect four single pole Type 1 & Type 1+2 (except for Type 1 with Ifi = 7 ka) - Bus bar 3N 2CTB81102R Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ ABB /9
9 Selection tables T2 Surge Protective Devices, Type 2 Function: Type 2 are surge arresters. They can handle energy from distant/ indirect lightning strikes or from switching operations. Type 2 can not discharge high energies from direct lightning like Type 1 but they feature lower protection level (Up). They are recommended at the incoming of installation for locations with no exposure to direct lightning impulses. Application: residential, commercial, industrial Standard: IEC / EN /20 current wave, varistor technology 2CSC400303F0201 2CSC400304F0201 2CSC400302F0201 2CSC400301F0201 2CSC400311F0201 2CSC400311F0201 2CSC400311F0201 Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection voltage operating details piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. Type 2 (pluggable) TNS, TNC OVR T P 2CTB80381R OVR T P 2CTB80381R OVR T s P 2CTB80381R OVR T P TS 2CTB80381R OVR T s P TS (3) 2CTB80381R OVR T s P 2CTB80381R OVR T s P TS (3) 2CTB80381R IT, TNS, TNC OVR T P 2CTB80381R OVR T P 2CTB80381R OVR T s P 2CTB80381R OVR T P TS 2CTB80381R OVR T s P TS (3) 2CTB80381R OVR T s P 2CTB80381R OVR T s P TS (3) 2CTB80381R OVR T s P TS (3) 2CTB80391R TT, TN-S (1 Ph+N) 1+N 1/70 (1) (1) 1.0/1.4 (1) /2 (1) OVR T2 1N 1 27 P 2CTB80392R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 1N P 2CTB80392R N 40/70 (1) 20 (1) 1.4/ /2 OVR T2 1N 40 27s P 2CTB80392R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 1N P TS 2CTB80392R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 1N 40 27s P TS (3) 2CTB80392R N 70/70 (1) 30 (1) 1./ /2 OVR T2 1N s P 2CTB80392R N 70/70 (1) 30 (1) 1./1.4 (1) /2 (1) OVR T2 1N 70 27s P TS (3) 2CTB80392R TNC 3 1 (2) (2) OVR T2 3L 1 27 P 2CTB80383R (2) 20 (2) OVR T2 3L P 2CTB80383R (2) 20 (2) OVR T2 3L 40 27sP 2CTB80383R (2) 20 (2) OVR T2 3L P TS 2CTB80383R (2) 20 (2) OVR T2 3L 40 27s P TS (3) 2CTB80383R (2) 30 (2) OVR T2 3L s P 2CTB80383R (2) 30 (2) OVR T2 3L 70 27s P TS (3) 2CTB80383R TNS 4 1 (2) (2) OVR T2 4L 1 27 P 2CTB80383R (2) 20 (2) OVR T2 4L P 2CTB 80383R (2) 20 (2) OVR T2 4L 40 27sP 2CTB80383R (2) 20 (2) OVR T2 4L P TS 2CTB80383R (2) 20 (2) OVR T2 4L 40 27s P TS (3) 2CTB80383R (2) 30 (2) OVR T2 4L s P 2CTB803919R (2) 30 (2) OVR T2 4L 70 27s P TS (3) 2CTB803919R TT, TN-S (3 Ph+N) 3+N 1/70 (1) (1) 1.0/1.4 (1) /2 (1) OVR T2 3N 1 27 P 2CTB80393R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 3N P 2CTB80393R N 40/70 (1) 20 (1) 1.4/ /2 OVR T2 3N 40 27sP 2CTB80393R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 3N P TS 2CTB80393R N 40/70 (1) 20 (1) 1.4/1.4 (1) /2 (1) OVR T2 3N 40 27s P TS (3) 2CTB80393R N 70/70 (1) 30 (1) 1./ /2 OVR T2 3N s P 2CTB80393R N 70/70 (1) 30 (1) 1./1.4 (1) /2 (1) OVR T2 3N 70 27s P TS (3) 2CTB80393R (1) L-N / N-. (2) per pole. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. The safety reserve(s) ensures a preventive maintenance of the installation. TT*: in TT network for L/N protection only Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ /10 ABB
10 Selection tables Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack T2 poles discharge discharge protection voltage operating details piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. 2CSC400310F0201 2CSC400307F0201 2CSC400310F0201 2CSC400309F0201 2CSC400309F0201 2CSC400309F0201 2CSC400303F0201 TT (3 Ph+N), TNS 3+N 1 1./1.4 (1) /2 (1) OVR T2 3N P 2CTB80393R N /1.4 (1) /2 (1) OVR T2 3N P 2CTB80393R N /1.4 (1) /2 (1) OVR T2 3N P TS (3) 2CTB80393R N /1.4 (1) /2 (1) OVR T2 3N s P TS (3) 2CTB80393R N /1.4 (1) /2 (1) OVR T2 3N s P 2CTB80393R N /1.4 (1) /2 (1) OVR T2 3N s P TS (3) 2CTB80393R TNC, IT OVR T2 3L P 2CTB80383R OVR T2 3L P TS 2CTB80383R OVR T2 3L s P 2CTB80383R OVR T2 3L s P TS 2CTB80383R TNS, IT /1.4 (1) OVR T2 4L P 2CTB80383R /1.4 (1) OVR T2 4L P TS 2CTB80383R /1.4 (1) OVR T2 4L s P 2CTB80383R /1.4 (1) OVR T2 4L s P TS 2CTB80383R Type 2 Neutral OVR T2 70 N P 2CTB80393R OVR Type 2 Special 24/48V AC & DC These type 2 SPD s can be used in very low voltages & data lines for current higher than 140mA OVR 1 7 P 2CTB81381R OVR 1 7 P TS 2CTB81381R / OVR P 2CTB81382R / OVR P TS 2CTB81382R / OVR 2 1 7s P TS 2CTB81382R Back-up protection by fuse: 16A gg under AC, 16A gr under DC Replacement cartridges for Surge Protective Devices Type 2 Phase cartridge, 7 V OVR 1 7 C 2CTB81384R Phase cartridge, 27 V OVR T C 2CTB80384R OVR T C 2CTB80384R OVR T s C (1) 2CTB80384R OVR T s C (1) 2CTB80384R Neutral cartridge for products OVR T2 1N (..) & OVR T2 3N (..), 27 V OVR T2 70 N C 2CTB80384R Phase cartridge, 440 V OVR T C 2CTB80384R OVR T C 2CTB80384R OVR T s C (1) 2CTB80384R OVR T s C (1) 2CTB80384R T2+T3 3N Nb. of Maxi. Nominal Voltage Voltage Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection protection combination voltage operating details piece group 1 piece unit current current level level wave Un voltage Imax In Up Up Uoc Uc (8/20) (8/20) at Uoc ka ka kv kv kv V V Type code Order code EAN kg ppc. Type 3 (non pluggable) 1+N / / OVR 1N CTB813912R N / / OVR 3N CTB813913R Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ ABB /11
11 Selection tables T2 3N auto-protected 2CSC400309F0201 Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection voltage operating details piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. Type 2 (non pluggable) / OVR T CTB804200R / OVR T CTB804201R / OVR T CTB804200R / OVR T CTB804201R / OVR T2 3L CTB804600R / OVR T2 3L CTB804601R / OVR T2 4L CTB804600R / OVR T2 4L CTB804601R N GND TC L 2CSC400309F0201 2CSC400309F0201 2CSC400309F0201 OVR Plus with integrated end of life protection (auto-protected) N+1 40*/40 20/40 1.6/ /2 OVR Plus N1 40 2CTB803701R N+3 1/60 /40 1.3/1. 230/ OVR Plus N3 1 2CTB803701R N+3 40/60 20/40 2/1. 230/ OVR Plus N3 40 2CTB803701R *Im = Imax MOV Surge Protective Devices, Low current The transmission line pluggable surge arresters (OVR TC P) provide protection against transient overvoltages for quipment connected to telephone lines (digital or analog), computer links or current loops, for applications such as RS-48, or 4-20 ma OVR TC 6V P 2CTB804820R OVR TC 12V P 2CTB804820R OVR TC 24V P 2CTB804820R OVR TC 48V P 2CTB804820R OVR TC 200V P 2CTB804820R OVR TC 200FR P 2CTB804820R OVR TC 6V C 2CTB804821R OVR TC 12V C 2CTB804821R OVR TC 24V C 2CTB804821R OVR TC 48V C 2CTB804821R OVR TC 200V C 2CTB804821R OVR TC 200FR C 2CTB804821R Base OVR TC RJ11 2CTB804840R Base OVR TC RJ4 2CTB804840R Surge Protective Devices, Photovoltaic OVR TC P 200 V in parallel OVR TC P / xx V / 200 FR in series PV 2CSC400309F0201 OVR PV 600 V 2CSC400001F0202 The specific OVR PV range offer a safe and efficient protection against transient overvoltages for equipments on photovoltaic installations. The OVR PV range comply with the UTE C on surge protective devices connected to photovoltaic generators. Impulse Maxi. Nominal Voltage Max. Short circuit Order Bbn Price Price Weight Pack current discharge discharge protection Cont. DC current details piece group 1 piece unit current current level Operating withstand Iimp Imax In Up Voltage Iscwpv (10/30) (8/20) (8/20) Ucpv ka ka ka kv V A Type code Order code EAN kg ppc. Type 1 PV, 9 poles OVR PV T P TS 2CTB80393R OVR PV T P TS 2CTB80393R Type 2 PV. 3 poles OVR PV P 2CTB80393R OVR PV P TS 2CTB80393R OVR PV P 2CTB80393R OVR PV P TS 2CTB80393R Replacement cartridges for Surge Protective Devices OVR PV OVR PV T C 2CTB80390R OVR PV T C 2CTB80390R OVR PV C 2CTB80390R OVR PV C 2CTB80390R OVR PV MC 2CTB80390R NEW /12 ABB
US Catalog March Surge protective devices (SPDs) UL range
US Catalog March 017 Surge protective devices (SPDs) UL range Surge protective devices (SPDs) UL range Introduction 1 1 OVR surge protective devices Joslyn surge protective devices Marketing tools 4 US
More informationCONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection
CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationAutoprotected Surge Arresters New OVR Plus range
Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationOvervoltage Protection
Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationETITEC - Lightning and Surge Arresters
ETITEC Lightning and Surge Arresters Overvoltage protection selection ETITEC selection Define system data: U max Uc > 1,2 x U max External lightning protection exist? NO Apply ETITEC C on string and on
More informationType of surge arrester
ipf surge arresters Type 2 or 3 LV surge arresters The ipf multi-pole single-piece surge arrester range is adapted for earthing systems: TT, TN-S,. Type 2 surge arresters are tested with a 8/20 µs current
More informationOvervoltage Protection Devices
Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationReliability in Surge Protection. Photovoltaic Systems.
Reliability in Surge Protection Photovoltaic Systems www.citelcp.com Roof top installations For low power PV applications, i.e. residences and small offices, it is necessary to consider surge protecting
More informationSingle Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th
V20 -S U oc 20kV ¾ SPD with high energy MOV technology ¾ Max discharge current up to 20kA 8/20μs and open circuit voltage U oc to 20kV. ¾ Pluggable module for easy replacement ¾ Reliable thermal disconnector
More informationwietap wietap Overvoltage Protection Tensions running high
wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as
More informationCirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device
A1 Cirprotec Specialists in Lightning and Surge Protection for Photovoltaic Systems Includes new plugin range and insulation monitoring device Complete protection systems with maximum continuity of service
More informationLeutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14
Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationSurge & Filter Protection Addressing your industrial power quality needs.
Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More information3 Design of the electrical installation protection system
J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationPage 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P
Page -4 Page -4 SURGE PROTECTIO DEVICES TY 1 AD 2 MOOBOCK VERSIOS 1P, 1P+, 2P, 3P, 3P+, 4P IEC impulse current Iimp (10/350μs): 25kA IEC maximum discharge current Imax (8/20μs): 100kA SPD status indicator
More informationModular surge protective devices (SPDs) Cat. Nos :
Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information
More informationL*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA
Prosurge BSF series surge filter is two-port Surge Protective Device with LC Filter especially for low-voltage power supply system surge protection at the boundaries from lightning protection zone 0 B
More informationSURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT
SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT FOR INDUSTRIAL, COMMERCIAL AND DOMESTIC ELECTRICAL INSTALLATIONS Surge Protection Devices and its Partner Companies have been solving problems in Lightning
More information2 Principle of lightning protection
2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More informationExtract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards
Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs
More informationLightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany
Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning
More informationModular surge protective devices
S D 870 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Modular surge protective devices Cat. o(s): 039 10-030 00/0//3/7 age /L 1. General characteristics... 1. Overall dimensions....1-3.
More informationSurge Protective Device
Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationProtection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device
Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE Surge Protection Device CHOICE OF SURGE PROTECTION DEVICES FOR PHOTOVOLTAIC APPLICATIONS General concept To achieve complete functionality
More informationS400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks
S400 Series HIGH EFFICIENCY SURGE PROTECTIONS For power supply For measurement and control devices For LAN / ICT Networks S400 Series High Efficiency Surge Protections High Efficiency Surge Protections
More informationENGR. MARITES R. PANGILINAN, P.E.E.
ENGR. MARITES R. PANGILINAN, P.E.E. WHAT IS LOW VOLTAGE INSULATION COORDINATION AND WHY IT IS IMPORTANT WHERE DO SURGES COME FROM HOW DO SPDs WORK/TYPE OF SPDs SPD SPECIFICATIONS SPD COORDINATION /CASCADING
More informationLightning Current Equipotential Bonding SPDs
Lightning Current Equipotential Bonding SPDs Introduction Furse is a world leader in the design, manufacture, and supply of earthing and lightning protection systems. Over 100 years of experience makes
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationBuilding Surge Protection Information Pack
Building Surge Protection Information Pack For All Your Surge Solutions PD Devices Ltd. Old Station Yard, South Brent, Devon, UK, TQ10 9AL W: www.pddevices.co.uk T: +44 (0)1364 649248 E: sales@pddevices.co.uk
More informationTechnical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:
Technical Data Circuit Protection - Surge Protection Devices Ver 1.0 CUSPD1110 Brief product description: Surge Protection Device (SPD) protect against lightning surges and man made surges such as motors,
More informationSurge Protection for Surveillance Systems
Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:
More informationVAL-CP-3S-350. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page
More informationDSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationCoordination of Surge protection devices
Coordination of Surge protection devices Design guide Surge arresters for commercial and industrial buildings Surge protection devices: how to choose them? coordination How to choose surge protection devices?
More informationSPD Catalogue. SPD Catalogue. for AC applications
SPD Catalogue SPD Catalogue for AC applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make
More informationPRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION
INTERNAL PROTECTION systems PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION INDUSTRIAL INSTALLATIONS 2 1 2 5 5 7 2 2 2 2 4 6 6 7 3 OBJECT: Industrial premises, Industrial complexes, Hospitals, Public buildings
More informationSurge Protection Solutions
Surge Protection Solutions SOLUTIONS guide Surge-Trap Type 2 fail-safe Surge Protective Devices Mersen Surge Protection Solutions 1 Reducing the impact of transient damage Surge-Trap SPD offers a patented
More informationPT 2X2-24DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationSurge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates
Application note Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates ABB OVR Series Electrical surges can be a real downer. Sherwood Construction's stone quarry in Tulsa, Oklahoma,
More informationTT-2-PE-M-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,
More informationTT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage
More informationLightning & Surge Protection
Watchful Eye olutions, Inc. WTH-120, WTH-165/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-165/G/1-255
More informationNEW surge protective devices
NEW surge protective devices For use in low-voltage systems For overhead power lines and buildings Made in EU ABOUT COMPANY INTRODUCTION Company ELEKTROMEHANIKA & BB d.o.o. was established from recent
More informationLightning & Surge Protection for Wind Turbine Systems
Lightning & Surge Protection for Wind Turbine Systems Product Selection Guide Table of Contents Technologies for Wind Turbine Protection 3 Protective Device Recommendations 4 Class I Strikesorb Surge Protection
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationBS th Edition wiring regulations Furse overview
BS 7671 18th Edition wiring regulations Furse overview Transient overvoltage protection TRANSIENT OVERVOLTAGE PROTECTION - RISK ASSESSMENT TO BS 7671 Furse electronic systems protection Enhanced solutions
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More informationLightning & Surge Protection
Watchful Eye olutions, Inc. WTH-300, WTH-500/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-300/G
More informationTT-2-PE- 24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24
More informationMiniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :
Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique
More informationPT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal
More informationInstallation / Control Technique
Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or
More informationThe Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE
The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination Hans Slagter, DEHN + SOHNE Earthing, Bonding & Surge Protection Conference, Auckland 2012 Discussion topics 1. Introduction
More informationSurge Protection for Low Voltage Power Systems
Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationIncreased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse
Increased Safety for Switchgear Cabinets CI Arresters with Backup Fuse www.dehn-international.com 1 fuse 1 2 fuse monitoring 2 3 Considerable space saving 3 Innovative solution to save space in the switchgear
More informationCONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters
CONNECT AND PROTECT nvent ERICO Critec SRF N-Series Surge Reduction Filters TABLE OF CONTENTS PROVEN FOR CRITICAL APPLICATIONS... 3 SRF N-SERIES COMBINED TECHNOLOGY PROTECTION... 4 SPARK GAP TECHNOLOGY...
More informationPT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5
More informationRemote contact signaling available. visual status indication
Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual
More informationPT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,
More informationmcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches
NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationR3&A Limited, Cobourg, ON
R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationDatasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations
Datasheet SPD II 1 Surge Protectors for A Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Weidmuller s SPD II 1 series transient voltage surge protectors consist of a range
More informationProduct Overview Surge Protective Devices
Product Overview Surge Protective Devices 2018 Who we are What we do SALTEK is a leading Czech based company specialising in the development and production of Surge Protective Devices. SALTEK offers a
More informationUS CATALOG SMISSLINE TP
US CATALOG SMISSLINE TP 2 SMISSLINE TP US CATALOG SMISSLINE TP US CATALOG 3 Table of contents 004 Description 005 012 for UL 508 and UL 489 based solutions Overview and ordering information 013 014 for
More informationReliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.
Reliability in Surge Protection Surge Protection AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes www.citel.us CITEL Established in 1937, CITEL is the global leader in the development and
More informationELECTRONICS Electronics
ELECTRONICS CONTA-ELECTRONICS CONTA-ELECTRONICS Overview of the product line Conta-Clip Our Company 3 CONTA-CLIP on the internet 4 CONTA-ELECTRONICS General Information 5 Product overview 6 DC power supplies
More informationSurge Protective Device
SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous
More informationPV protective solutions
PV SPD catalogue PV protective solutions for solar PV applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
More informationDatasheet Stock No: RS Pro
Datasheet Stock No: 9012718 RS Pro Product Details: Our RS Pro metal oxide varistors have been designed to meet the abnormal overvoltage requirements outlined in Section 39.4 of the UL1449 standard (4
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationUS Catalog July 2016 SMISSLINE TP
US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information
More informationOvervoltage Protection for low-voltage supplies
Class I Overvoltage Protection.2 -.3 with sparkover gaps.4 -.9 with high-power varistors.10 -.11 Overvoltage Protection, combination arrester.12 -.15 Class II Overvoltage Protection with varistors.16 -.25
More informationCARLO GAVAZZI Automation Components. Surge Protection Devices
CARLO GAVAZZI Automation Components Surge Protection Devices DSF, DSB and DSC Surge Protection Devices Carlo Gavazzi range of Surge Protection Devices has been developed in order to fulfil any application
More informationvoltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection
voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationLightning and Surge Protection for PV Systems
Lightning and Surge Protection for PV Systems Application Note (AU) Phillip Tompson Introduction Like all electrical equipment photovoltaic systems can be damaged by both direct and indirect lightning
More informationic60n RCBO 30 ma IEC , IEC , AS/NZS
ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of
More informationCompany Profile Surge Protective Devices
Company Profile Surge Protective Devices Who we are What we do SALTEK is a leading Czech based company specialising in the development and production of Surge Protective Devices. SALTEK offers a complete
More informationSurge Protection Devices OVR series
PRODUCT CATALOGUE CANADA Surge Protection Devices OVR series UL / CSA range of SPDs Type 1 and Type 2 for main electrical distribution equipment and control panel applications Hardwired and DIN rail versions
More informationType 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016
Type 1 Arresters Use in installations with short-circuit currents up to 100 ka rms Definition of follow current, follow current extinguishing capability and short-circuit withstand capability Follow current
More informationLightning and Surge Arresters
/ Lightning and Surge Arresters Product overview /3 Introduction /6 Lightning arresters, requirement category I (B) /8 Combination arresters, requirement category I (B) and II (C) /0 Single-pole surge
More information