1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
|
|
- Silvester Benson
- 5 years ago
- Views:
Transcription
1 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications Selection Product Selection Accessories Technical Data and Specifications Dimensions Page V-T- V-T- V-T- V-T-8 V-T-7 V-T-78 WMZS Circuit Breaker Product Overview Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eaton s WMZS DIN rail mountable circuit breaker is designed for use in control panel applications.the WMZS is available with B, C and D characteristics in accordance with UL 077, CSA C. No. and IEC Application Description Supplementary protection: Control circuits Lighting Business equipment Appliances Features Complete range of UL 077 Recognized DIN rail mounted miniature circuit breakers up to A current rating Standard ratings of 0 kaic at 77/80 Vac Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit Offers supplementary protection Thermal-magnetic overcurrent protection Three levels of shortcircuit protection, categorized by B, C and D curves Trip-free design breaker can not be defeated by holding the handle in the ON position Captive screws cannot be lost Fulfill UL 077, CSA C. No. and also IEC 097- Standard Field-installable shunt trip and auxiliary switch subsequent mounting Module width of only 0.9 inches (7. mm) per pole Contact Position Indicator (red/green) Easy installation on DIN rail Possibility for sealing the toggle in ON or OFF position V-T- Volume Circuit Protection CA080000E September 0
2 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Advanced Features Breakers install on standard DIN rail Available in single-, two- and three-pole models Color-coded indicator provides breaker status for easy troubleshooting Selection Breaker Family WMZS = Supplementary Protector Captive posidrive terminal screws with finger and backof-hand protection (IP0) Trip-free design; breaker cannot be defeated by holding the handle in the ON position Breaker information printed on the front of the device for quick identification of Poles = Single-pole = Two-pole = Three-pole WMZS B 0 Standards and Certifications Worldwide Acceptance WMZS Supplementary Protectors are UL Recognized for use in the United States in accordance with NFPA 70 (NEC). The devices comply with UL 077 and CSA. No., meeting the requirements for supplementary protectors. These devices are for international and domestic use, and also comply with IEC 097- and are CE marked. These devices are RoHS compliant. Protective Curve B = B Curve ( X I n ) C = C Curve ( 0X I n ) D = D Curve (0 0X I n ) 00 = 0.A 0 = A 0 = A 0 = A 0 = A 0 = A 0 = A Ampere Rating 07 = 7A 08 = 8A 0 = 0A = A = A = A 0 = 0A = A 0 = 0A = A 0 = 0A 0 = 0A = A Volume Circuit Protection CA080000E September 0 V-T-
3 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Product Selection WMZS Product Selection B Curve ( X I n Current Rating) Suitable for applications where protection against low level short circuit faults in control wiring is desired. Instantaneous trip is X continuous rating of device (I n ). Applications include PLC wiring, business equipment, lighting, appliances and some motors. Low magnetic trip point. Single-Pole Two-Pole Three-Pole B Curve ( X I n Current Rating) Designed for Resistive or Slightly Inductive Loads Amperes Single-Pole Two-Pole Three-Pole WMZSB0 WMZSB0 WMZSB0 7 WMZSB07 WMZSB07 WMZSB07 8 WMZSB08 WMZSB08 WMZSB08 0 WMZSB0 WMZSB0 WMZSB0 WMZSB WMZSB WMZSB WMZSB WMZSB WMZSB WMZSB WMZSB WMZSB 0 WMZSB0 WMZSB0 WMZSB0 WMZSB WMZSB WMZSB 0 WMZSB0 WMZSB0 WMZSB0 WMZSB WMZSB WMZSB 0 WMZSB0 WMZSB0 WMZSB0 0 WMZSB0 WMZSB0 WMZSB0 WMZSB WMZSB WMZSB WMZS Product Selection C Curve ( 0X I n Current Rating) Suitable for applications where medium levels of inrush current are expected. Instantaneous trip is 0X rating of device (In). Applications include small transformers, lighting, pilot devices, control circuits, and coils. Medium magnetic trip point. Single-Pole Two-Pole Three-Pole C Curve ( 0X I n Current Rating) Designed for Inductive Loads Amperes Single-Pole Two-Pole Three-Pole 0. WMZSC00 WMZSC00 WMZSC00 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 WMZSC0 7 WMZSC07 WMZSC07 WMZSC07 8 WMZSC08 WMZSC08 WMZSC08 0 WMZSC0 WMZSC0 WMZSC0 WMZSC WMZSC WMZSC WMZSC WMZSC WMZSC WMZSC WMZSC WMZSC 0 WMZSC0 WMZSC0 WMZSC0 WMZSC WMZSC WMZSC 0 WMZSC0 WMZSC0 WMZSC0 WMZSC WMZSC WMZSC 0 WMZSC0 WMZSC0 WMZSC0 0 WMZSC0 WMZSC0 WMZSC0 WMZSC WMZSC WMZSC Notes In North America, these switches are UL recognized and CSA certified as Supplementary Protection devices. Per the intent of NEC (National Electrical Code), Article 0, and CEC (Canadian Electrical Code), Part C., supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. Designed for resistive or slightly inductive loads. Response time of instantaneous trip: X I n current rating. Designed for inductive loads. Response time of instantaneous trip: 0X I n current rating. V-T- Volume Circuit Protection CA080000E September 0
4 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. WMZS Product Selection D Curve (0 0X I n Current Rating) Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 0 0X rating of device (I n ). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies. Single-Pole Two-Pole Three-Pole D Curve (0 0X I n Current Rating) Designed for Inductive Loads Amperes Single-Pole Two-Pole Three-Pole 0. WMZSD00 WMZSD00 WMZSD00 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 WMZSD0 7 WMZSD07 WMZSD07 WMZSD07 8 WMZSD08 WMZSD08 WMZSD08 0 WMZSD0 WMZSD0 WMZSD0 WMZSD WMZSD WMZSD WMZSD WMZSD WMZSD WMZSD WMZSD WMZSD 0 WMZSD0 WMZSD0 WMZSD0 WMZSD WMZSD WMZSD 0 WMZSD0 WMZSD0 WMZSD0 WMZSD WMZSD WMZSD 0 WMZSD0 WMZSD0 WMZSD0 Notes In North America, these switches are UL recognized and CSA certified as Supplementary Protection devices. Per the intent of NEC (National Electrical Code), Article 0, and CEC (Canadian Electrical Code), Part C., supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required. Designed for highly inductive loads. Response time of instantaneous trip: 0 0X I n current rating. Volume Circuit Protection CA080000E September 0 V-T-7
5 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Accessories Auxiliary Contacts and Voltage Trips Module Circuit Diagram Description Standard Auxiliary Contacts Auxiliary/Trip Indicating Contact Undervoltage Trip Shunt Trip Allowable Combinations of Accessories H N.... D U D C C OFF.. NO/NC Installs on left side of WMZS or shunt trip Max. one per WMZS (077) device Switches when WMZS is tripped electrically or manually Small selector screw changes mode Two Form C (changeover) contacts Installs on left side of WMZS or shunt trip Auxiliary contacts switch when WMZS is tripped electrically or manually Trip indicating contact switches only when WMZS is tripped electrically Prevents WMZS from operating unless voltage is present Installs on left side of WMZS Includes test button Allows remote trip of WMZS Installs on left side of WMZS AUX AUX WMZS AUX AUX WMZS WMZS TRIP TRIP or Circuit Breaker or Shunt Trip Circuit Breaker UnderV Trip Rated Operational Voltage 0 Vac WMZSAUX 0 Vac WMZSAUXTRIP Vac WMZSUVR 0 Vac WMZSUVR0 00 Vac WMZSUVR00 0 Vac WMZSST 0 0 Vdc 0 Vac WMZSST0 0 Vdc Circuit Breaker V-T-8 Volume Circuit Protection CA080000E September 0
6 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Busbar System Description Without Auxiliary Contacts For connecting WMZS Supplementary Protectors without auxiliary contacts. May be fed from line or load side. WMZS WMZS WMZS Auxiliary/Trip Indicating Contact For connecting WMZS Supplementary Protectors with auxiliary contacts. May be fed from line or load side. WMZS WMZSBCONA lb-in ( Nm) WMZS lb-in (. Nm) WMZSEXT Rated Operational Current (A) of Poles per Device of Terminals 80 7 WMZSP7T WMZSPT 7 WMZSP7T 00 7 WMZSP7T WMZSPT 7 WMZSP7T 80 7 WMZSP7TAUX WMZSPTAUX 8 WMZSP8TAUX 00 7 WMZSP7TAUX WMZSBBTC 0 lb-in (. Nm) WMZSPTAUX 8 WMZSP8TAUX WMZSCAP or WMZSCAP Volume Circuit Protection CA080000E September 0 V-T-9
7 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Incoming Terminal Pin Type Incoming Supply Terminals Description Accommodates conductors from mm /#0 AWG. Nm/ 0 lb-in Finger-safe connection WMZSEXT Incoming Terminal Bus Incoming Supply Terminals Description 0 mm # AWG 7 Deg Wire A/Y, 80V UL 0A/Y 90V IEC WMZSBCONA Busbar Terminal Cover Protective Accessories Description For covering unused terminals WMZSBBTC Fork Connector Two- and Three-Pole Busbar End Cap Description Install after cutting busbar Protects end of busbar of Poles and WMZSCAP Padlock Hasp Prevents reactivation of the device during maintenance Holds one padlock WMZPLK Fork Connector Two- and Three-Pole WMZSCAP V-T-70 Volume Circuit Protection CA080000E September 0
8 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Technical Data and Specifications Trip Curve Charts Three Tripping Curves to Choose Eaton WMZS Supplementary Protectors are available with three different tripping characteristics, including Type B, C and D. Definitions for each trip curve are contained on the ordering pages and can be used to determine the optimal characteristic for your application. For example, low level short-circuit faults in control wiring, such as PLCs, are best protected by devices with Type B trip characteristics ( to X continuous rating of the device (I n ). Even though not required by NEC or CEC for Supplementary Protectors, Eaton s WMZS devices are current limiting, which means they interrupt fault currents within one half cycle. Current limiting devices offer superior protection by reducing peak let-through current and energy. WMZS Tripping Curves t [sec] Time-current characteristic acc. to UL 077 conventional non-tripping current I nt =. I N : t > h conventional tripping current I t =. I N : t < h B C I / I N D. I N : t = 0 s (I N < A) t = 0 s (I N < A) Type B: I N : t > 0. s Type B: I N : t < 0. s Type C: I N : t > 0. s Type C: 0 I N : t < 0. s Type D: 0 I N : t > 0. s Type D: 0 I N : t < 0. s Volume Circuit Protection CA080000E September 0 V-T-7
9 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors B Curve D Curve Specified non-tripping current I NT =. x I N for t > h Specified tripping current I T =. x I N for t < h. I N : t = 0 s (I N < A) t = 0 s (I N > A) Type B: x I N : t > 0. s Type B: x I N : t < 0. s Type C: x I N : t > 0. s Type C: 0 x I N : t < 0. s Type D: 0 x I N : t > 0. s Type D: 0 x I N : t < 0. s Specified non-tripping current I NT =. x I N for t > h Specified tripping current I T =. x I N for t < h. I N : t = 0 s (I N < A) t = 0 s (I N > A) Type B: x I N : t > 0. s Type B: x I N : t < 0. s Type C: x I N : t > 0. s Type C: 0 x I N : t < 0. s Type D: 0 x I N : t > 0. s Type D: 0 x I N : t < 0. s t [sec] B C D t [sec] B C D I / I N I / I N C Curve t [sec] Specified non-tripping current I NT =. x I N for t > h Specified tripping current I T =. x I N for t < h. I N : t = 0 s (I N < A) t = 0 s (I N > A) Type B: x I N : t > 0. s Type B: x I N : t < 0. s Type C: x I N : t > 0. s Type C: 0 x I N : t < 0. s Type D: 0 x I N : t > 0. s Type D: 0 x I N : t < 0. s B C D I / I N V-T-7 Volume Circuit Protection CA080000E September 0
10 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Technical Data Description B Curve C Curve D Curve Electrical Approvals UR (UL 077), CSA (CSA. No. ), CE Standards IEC/EN 097- Short-circuit trip response I n 0 I n 0 0 I n Supplementary Protectors UL/CSA Current range A 0. A 0. 0A Maximum voltage ratings UL/CSA Single-pole 77 Vac 77 Vac 77 Vac 8 Vdc 8 Vdc 8 Vdc Two-, three-pole 80Y/77 Vac 80Y/77 Vac 80Y/77 Vac Two poles in series 9 Vdc 9 Vdc 9 Vdc Thermal tripping characteristics Single-pole. x I n at 0 C. x I n at 0 C. x I n at 0 C Multi-pole. x I n at 0 C. x I n at 0 C. x I n at 0 C Short-circuit ratings (at max. voltage) Single-pole 0 ka ( ka for 0 A device) 0 ka ( ka for 0 A device) ka Two-, three-pole 0 ka ( ka for 0 A device) 0 ka ( ka for 0 A device) ka Single-pole 0 ka at 8 Vdc 0 ka at 8 Vdc 0 ka at 8 Vdc Two poles in series 0 ka at 9 Vdc 0 ka at 9 Vdc 0 ka at 9 Vdc Miniature Circuit Breaker IEC Current range A 0. A 0. 0A Maximum voltage ratings IEC 097- Single-pole 0 Vac 0 Vac 0 Vac 8 Vdc 8 Vdc 8 Vdc Two-, three-pole 0/00 Vac 0/00 Vac 0/00 Vac Maximum voltage ratings IEC 0898 Single-pole 0 Vac 0 Vac 0 Vac 8 Vdc 8 Vdc 8 Vdc Two-, three-pole 0/ Vac 0/ Vac 0/ Vac Thermal tripping characteristics Single-pole > hour at.0 x I n > hour at.0 x I n > hour at.0 x I n Multi-pole < hour at. x I n < hour at. x I n < hour at. x I n Interrupting ratings (at max. voltage) IEC 097- ka ka ka IEC ka 0 ka 0 ka Operational switching capacity 7. ka 7. ka 7. ka Max. back-up fuse [gl/gg] A A A Rated impulse withstand U imp 000 Vac 000 Vac 000 Vac Rated insulation voltage U i 0 Vac 0 Vac 0 Vac Volume Circuit Protection CA080000E September 0 V-T-7
11 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Technical Data, continued Description B Curve C Curve D Curve Environmental/General Selectivity class Lifespan (operations) > 0,000 ( operation = ON/OFF) > 0000 ( operation = ON/OFF) > 0000 ( operation = ON/OFF) Shock (IEC 8--) 0g 0 ms 0g 0 ms 0g 0 ms Operating temperature range to 0 F ( to 0 C) to 0 F ( to 0 C) to 0 F ( to 0 C) Shipment and short-term storage 0 to 8 F ( 0 to 8 C) 0 to 8 F ( 0 to 8 C) 0 to 8 F ( 0 to 8 C) Housing material Nylon Nylon Nylon Mechanical Standard Front Dimension Device height 80 mm 80 mm 80 mm Terminal protection Finger and back-of-hand proof to IEC Finger and back-of-hand proof to IEC Finger and back-of-hand proof to IEC Mounting width per pole 7. mm 7. mm 7. mm Mounting IEC/EN 07 top-hat rail IEC/EN 07 top-hat rail IEC/EN 07 top-hat rail Degree of protection IP0 IP0 IP0 Terminals top and bottom Twin-purpose terminals Twin-purpose terminals Twin-purpose terminals Supply connection Line or load side Line or load side Line or load side Terminal capacity [mm ] x (AWG 8) / x 0 (AWG 8 8) x (AWG 8) / x 0 (AWG 8 8) x (AWG 8) / x 0 (AWG 8 8) Torque. Nm. Nm. Nm Imperial torque lb-in (AWG 8 ), lb-in (AWG 0 8), lb-in (AWG ) lb-in (AWG 8 ), lb-in (AWG 0 8), lb-in (AWG ) lb-in (AWG 8 ), lb-in (AWG 0 8), lb-in (AWG ) Thickness of busbar material 0.8 mm 0.8 mm 0.8 mm Mounting position As required As required As required V-T-7 Volume Circuit Protection CA080000E September 0
12 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Let-Through Energy I t Characteristic B and C i dt 0 [A s] Characteristic D i dt 0 [A s] I cc rms [ka] A 0 A 0 A A 0 A A A 0 A A A A A WMZS-...-BHI I cc rms [ka] A 0. A 0 A A A 0 A A A 0 A A Let-Through Current I D Characteristic B and C l 0 D 9 [A] Characteristic D l 0 D 9 [A] I cc rms [ka] A 0 A 0 A A A 0 A A A 0 A A A A A A 0. A I cc rms [ka] 0 A A A 0 A A A 0 A A Volume Circuit Protection CA080000E September 0 V-T-7
13 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Influence of the Ambient Temperature on the Thermal Tripping Behavior Corrected values of the rated current dependent on the ambient temperature Ambient Temperature T I n (A) C 0 C 0 C 0 C 0 C 0 C 0 C C 0 C C 0 C C 0 C Influence of the Mains Frequency Influence of the mains frequency on the tripping behavior I MA of the instantaneous release Mains Frequency f [Hz] Description / I MA (f)i MA (0 Hz) [%] Load Carrying Capacity of Adjoining Miniature Circuit Breakers Rated Diversity Factor of Circuit Breakers V-T-7 Volume Circuit Protection CA080000E September 0
14 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Technical Data Description WMZSAUX WMZSAUXTRIP WMZSST WMZSUVR Electrical Contact function A + B C/O Rated operational voltage U n 0 Vac Vac WMZSUVR 0 Vac WMZSUVR0 00 Vac WMZSUVR00 Voltage range WMZSST0 0 Vac 0 Vdc Voltage range WMZSST 0 Vac 0 0 Vdc Closing threshold [x U n ] 0.8 Tripping threshold [x U n ] 0. Rated frequency ƒ 0/0 Hz 0/0 Hz 0/0 Hz General use (UL/CSA) AC 0/0 Vac /A DC 0/0 Vdc 0./0.A Pilot duty A00/Q00 Conventional free air thermal current I th A Rated operational current AC- I e A (0 Vac) AC- I e A (0 Vac) DC- I e 0.A (0 Vdc) Rated insulation voltage U i 0 Vac Minimum operating voltage per contract U min Vdc Rated impulse withstand voltage (./0μ) U imp. kv Rated conditional short-circuit current with A back-up fuse I SC ka Max. admissible back-up fuse A gl Mechanical Standard front dimension mm mm mm Device height 80 mm 80 mm 80 mm Mounting width 8.8 mm 7. mm 7.8 mm Mounting On MCB IEC/EN 07 top-hat rail IEC/EN 07 top-hat rail Degree of protection enclosed IP0 IP0 IP0 Terminal protection Protection against electric shock to IEC Protection against electric shock to IEC Protection against electric shock to IEC Terminals Lift terminals Twin-purpose terminals Twin-purpose terminals Terminal capacity Solid 0.. mm. mm x (.) mm Flexible 0.. mm. mm x (.) mm Tightening torque of terminal screws Nm (7 9 lb-in). Nm ( lb-in) 0.8 Nm (7 lb-in) Volume Circuit Protection CA080000E September 0 V-T-77
15 . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors Dimensions Approximate Dimensions in Inches (mm) Miniature Circuit Breakers WMZS 0. (.).0 (0.) 0.8 (.). (80.0). (80.0). (80.0).77 (.0) 0.9 (7.).8 (.0).07 (.) P P P.7 (.0). (0.0) 0. (.0) Auxiliary Contacts WMZSAUX. (0.0).7 (.0) 0.08 (.0) 0.8 (9.) Shunt Releases WMZSST. (80.0).77 (.0). (80.0) 0. (8.9) WMZSAUXTRIP. (8.) 0. (.) 0. (.).77 (.0) 0.9 (7.).0 (.) 0. (.) Undervoltage Releases WMZSUVR 0. (.).7 (.0). (0.0) 0.9 (0.0) 0. (9.0). (0.0).7 (.0) 0.8 (9.). (80.0).77 (.0). (80.0) 0. (.).77 (.0) 0.70 (7.8) 0. (.).7 (.0). (0.0) V-T-78 Volume Circuit Protection CA080000E September 0
16 Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors. Approximate Dimensions in Inches (mm) Busbar and Accessory Weights and Dimensions Unit Weight Lbs (kg) Length Width Height WMZSP7T 0. (0.9) 9.7 (009.0) 0.9 (.0) 0.9 (.0) WMZSPT. (0.) 9.0 (99.0) 0.87 (.0). (7.0) WMZSP7T.8 (0.8) 9.7 (009.0) 0.87 (.0). (7.0) WMZSP7TAUX 0.7 (0.) 8.78 (98.0) 0.9 (.0) 0.9 (.0) WMZSPTAUX.9 (0.) 9.7 (009.0) 0.87 (.0). (7.0) WMZSP8TAUX.7 (0.79) 8. (98.0) 0.87 (.0). (7.0) WMZSP7T 0.79 (0.) 9.7 (009.0) 0.9 (.0) 0.9 (.0) WMZSPT.7 (0.79) 9.0 (99.0) 0.87 (.0). (7.0) WMZSP7T.9 (.0) 9.7 (009.0) 0.87 (.0). (7.0) WMZSP7TAUX 0.8 (0.) 8.78 (98.0) 0.9 (.0) 0.9 (.0) WMZSPTAUX. (0.7) 9.7 (009.0) 0.87 (.0). (7.0) WMZSP8TAUX. (0.97) 8. (98.0) 0.87 (.0). (7.0) WMZSEXT 0.07 (0.0). (0.0) 0.7 (7.0). (9.0) WMZSBCONA 0.07 (0.0).7 (0.0) 0.7 (8.0).8 (0.0) WMZSBBTC (0.00). (8.0) 0.7 (.0) 0.9 (.0) WMZSCAP 0.00 (0.00) 0. (.0) 0.0 (.0) 0.9 (0.0) WMZSCAP 0.00 (0.00) 0.9 (.0) 0.87 (.0) 0.9 (0.0) L H W Volume Circuit Protection CA080000E September 0 V-T-79
Product Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationControl Circuit and Load Protection Products
Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationBulletin 1492-MC 1492-MCGA, -MCEA 1492-SP
Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationSafety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths
DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 850R miniature control relays 850RS4 standard 850RS24 low level 850RS34 hermetically sealed Catalog 204 Contents Class 850R miniature control relays bbspecifications....................................................
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationMulti 9 System Catalog
Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics
More informationSupplemental Protectors
compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationIntroduction Electronic Circuit Protection ESX10-T
Introduction Electronic Circuit Protection ESX0-T Electronic circuit protection type ESX0-T is designed to ensure selective disconnection of 24VDC load systems. 24VDC power supplies, which are widely used
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationCat. No. 140M-F M-D8E-B
Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class 0 0 Rated Operational
More informationMax. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame
! Bulletin 0M Motor Circuit Protectors Type Coordination 00V Current Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 00V For Use With Contactors Below (or larger) 0M-CE-A
More informationRM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary
Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationRM35TF V AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationThe new Arc Fault Detection Device S-ARC1 Maximum safety easy installation
ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationSafety relay emergency stop/protective door, 230VAC, 3 enabling paths
DATASHEET - ESR5-NO-31-230VAC Safety relay emergency stop/protective door, 230VAC, 3 enabling paths Part no. ESR5-NO-31-230VAC Catalog No. 119380 EL-Nummer (Norway) 4133320 Delivery program Product range
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationRM4TR31 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationDSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More information140M C 2 E A63 KN CC GJ
Motor Protection Circuit Breakers Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection;
More information140M C 2 N A63 KN CC GJ
Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA
Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...
More informationCP30F Series Circuit Protector for Improving Safety and Wiring Workability
CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationMax. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2
Bulletin T Product Selection Thermal Overload Relays For Use With C C Setting Range [A] gl/gg Max. Backup fuse [A] UL Class K ka, V AC ka, V AC IEC/EN Coordination Type Type UL.. TAA.. TAA.. TAA.. TAA..
More informationSafety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths
DATASHEET - ESR5-NO-31-24VAC-DC Delivery program Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths Part no. ESR5-NO-31-24VAC-DC Catalog No. 118702 EL-Nummer (Norway) 4133318 Product
More informationUS BROCHURE. Circuit protection according to UL 489 and UL 1077
US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationRM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases
Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching
More information