1 MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures 1a, b, c. Module mounting (a) and fan sides (b) of MC 11 AC EB-2 cabinet, and (c) slot 0 panel. 1. General description REFER TO SECTION 10 FOR SAFETY AND EMC RELATED ITEMS FIRST The MC 11 AC EB-2 19" power supply cabinet with external bus has 11 free slots for TKH Security plug-in modules (7TE), supplying these with the correct DC voltages. The 'mains' power connector module in the remaining, dedicated slot 0 contains a microprocessor. This processor is used for: - status monitoring and controlling of SNM compatible modules and those from the AWS 3000 series in the cabinet; - controlling two relays; - reading status information of the cabinet proper. Two RS-485 serial bus interfaces to the processor are provided, allowing remote system management and control. By way of these interfaces, a large number of MC XX EB-2 cabinets may be linked with shielded 4(+1 ground)-wire data cable. More information on system control can be found in supplementary manuals; the cabinet can be set to EB compatibility. The 230 or 120 Vac-powered MC 11 AC EB-2 internals are cooled with two fans. Note that the cabinet mounting brackets can be put on the module side or on the fan side (see figures 1a,b). 2. Indicators and connectors In figure 1a, SLOT 0-SLOT 11 indicate the twelve Siqura 2017 Version f MC11AC EB-2 (MW10) module slots. An external earthing point (1) is provided on one shorter cabinet side. The front panel of the controller module has two 9-pin D-connectors for serial (external) communications, and two 2-pin relay connections 1 and 2 combined into one connector (see figures 1a, c and table 1). The controller module front panel furthermore provides a mains connector and an access panel for the mains fuse (figures 1a,c and 4). (AC connector) mains connector (fuse) power fuse holder strain relief stud (M4) CC o (4-p Combicon) relay contacts 1, 2 DATA o, 9-pin fem. D- RS-485 serial interfaces connector, 2x (1 active in EB-1 mode) Status LEDs *DC (green) DC power OK (internal) *EB (green) control data I/O *1 (red) relay 1 activated *2 (red) relay 2 activated Table 1. Panel layout of module S0. Note: the relay contacts are open when the MC 11 EB-2 is not powered. 3. Installation instructions for EB-2 mode 1. Choose the mode of operation (EB-2 absolute addressing, EB-2 local addressing, or EB compatibility mode, see 5). 2. Mount the MC 11 EB-2 cabinet into a standard 19-inch rack, without modules in the slots. Check whether the specified power voltage of the cabinet matches the local power supply voltage.

2 Note: to prevent overheating of the cabinet and inserted modules, provide air circulation room at the cabinet front and rear (10 cm) and bottom (1 cm). 3. The chassis should be connected to safety ground utilising the connection on the side wall of the cabinet (1 in figure 1a). 4. Fasten the power cord to the strain relief stud (see the hexagons in figures 1a and c, top). 5. Connect the power cord to the power supply and switch on power. The electric fans should be working; if not, disconnect power immediately and check the power voltage. 6. Power off the cabinet and install the TKH Security modules according to the instructions given in the user manuals of the modules. Slots not in use should be covered with 7TE blanking plates (BF 07). 7. Power on the cabinet. Both fans should be working, blowing outwards. 4. Care, maintenance and safety For reliable operation of the module, observe the following: - prevent dust from collecting on the equipment - protect the equipment against moisture - maintain sufficient cooling space around the equipment (see 3). - replace the electric fans every 5 years. Consult section 7 on how to replace fans. - replace blown fuses only with the types specified. Consult section 8 on how to change fuses. For ultimate safety, one should not remove, add or exchange modules while the power supply cabinet is operating. If a module causes a DC short on the secondary (output) side, the MC 11 will turn itself off; it can be restarted by taking power off for at least 4 seconds, then connecting it again. 5. Configuring the cabinet 5.1. General There are two basic operating modes: SNM (also loosely called EB-2) and EB (the latter providing compatibility with the older EB protocol; for EB ON Figure 2. Dip switches on the EB-2 controller board (details left out for clarity) ON DIP SWITCH BANK configuration see 5.3). Dip switches are used to set modes and parameters, which are not identical for the two modes. The dip switches for setting the parameters of MC 11 EB-2 cabinets are located on the board inside the module in the dedicated slot 0 (the EB-2 board: see figures 1a and 2). If the cabinet is already installed and filled with modules, these switches may be accessed - after powering off - by removing the modules from the first three or four adjoining slots. The position of switch no. 8 determines whether the module is in EB-2 or in EB mode (see table 2) SNM (EB-2) mode In SNM (EB-2) mode, the RS-485 transmission speed is fixed at 19.2 kbaud. The address (1-31) of the EB-2 module must be set if this module is to use EB-2 local addressing mode. These address switch settings are listed in table 3. Switch Set(s) 1-5 EB-2 address if set to local addressing using dip switches (see table 5) 6&7 off-off: EB-2 absolute addressing 6&7 on-off: EB-2 local (manual) addressing 8 compatibility mode: must be 0 (off) for EB-2 Table 2. Dip switch assignments in EB-2 mode. Switch Address Reserved default on on on on on on - on on on on on on on - 08 on - - on on - on - 10 on on - on on on - 12 on - on on on on on - 14 on on on on on 16 on on 17 - on - - on 18 on on - - on on - on 20 on - on - on 21 - on on - on 22 on on on - on on on 24 on - - on on 25 - on - on on 26 on on - on on on on on 28 on - on on on 29 - on on on on 30 on on on on on 31 Table 3. Setting the communication address of an MC 11 RS-485 interface in EB-2 local addressing mode or in EB mode. - = off. 2

3 5.3. Configuration for EB mode In EB (= EB-1) compatibility mode, switches 1-5 set the cabinet address, while switches 6 and 7 control the transmission rate (see tables 3-5). Switch Set(s) bit address of cabinet in EB mode 6-7 baud rate (see table 5) 8 always 1 (on) for EB mode Table 4. Switch assignments in EB mode Switch 6 7 Transmission rate (baud) on 4800 on on on 19.2 k Table 5. Setting the transmission rate of the RS-485 interface in EB mode Cabinet programming For more information on EB mode, consult the 'MC EB Users Manual for Remote Control'. SNM/EB-2 programming is taught in the SNM/EB-2 Programming Manual. 6. D-connector pin assignments The pin assignments of the 9-pin D-connectors are given in table 6 below. In EB-1 mode, only the leftmost D-connector (front view) is active. Pin Description 1 not connected 2 B tx' inverting output o (- out) 3 A tx' non-inverting output o (+ out) 4 B rx' inverting input o (- in) 5 A rx' non-inverting input o (+ in) 6 not connected 7 not connected 8 not connected 9 not connected Table 6. Pin assignment of the 9-pin D connectors 7. Replacing the electric fans (Qualified service personnel only) The two electric fans must be changed every five years (replacements may be obtained from TKH Security). The procedure for mounting a new fan is as follows (see also figure 3): 1. Power down the MC 11 EB-2 cabinet and wait >3 minutes. 2. Remove the black cover with the mounted fans. 3. Disconnect fans to be replaced from their power supplies (see figure 3: these two connectors sit side by side). Since the wires run between circuit board and panel, it will usually be necessary to loosen the screws holding the wires in the connectors. Do not disconnect the wires of the similarly shaped, single mains voltage connector at the opposite corner of the board. 4. Remove disconnected fans and replace them with new ones. Make certain the blowing direction is outwards. Please use the washers and nuts as indicated for one of the fastening screws. 5. Reconnect the fan power supply wires, observing correct polarities. Tighten the screws carefully. 6. Replace the cover. 7. Reconnect the power cabinet to the mains. Check whether the fan is blowing outwards. 8. Replacing and checking the primary fuses 1. Power down the MC EB-2 cabinet by disconnecting it from the power supply. 2. The primary fuse (1 in figure 4) is located right under the mains socket. Table 7 lists fuse data. 1 supply wires to second fan 1 2 circuit board Figure 3. Replacing a fan (view from above, left fan). A fan's power connector has two fastening screws for the fans' power supply wires; polarities are indicated on the circuit board. Figure 4. Replacing the fuse of the MC 11 AC EB-2 Power voltage fuse value type 230 Vac 250 V/1.6 A, time-lag glass, 5x20 mm 120 Vac 250 V/3.15 A, time-lag glass, 5x20 mm Table 7. Replacement fuses 3. Reconnect power to switch on the cabinet. 3

4 9. Technical specifications MC 11 AC EB-2 technical specifications are detailed in table 8 below. Electrical...Power: AC voltage nominal Vac AC voltage working Vac optional AC voltage nominal 120 Vac optional AC voltage working Vac frequency Hz maximum drop-out time 10 ms Secondary maximum load, continuous +15 V±5% max. current. 7.0 A 15 V±5% max. current 2.0 A +15 V±5% operational 5.5 A 15 V±5% operational 2.0 A AC input current 1.0 A AC input current 120 V model 2.0 A Power efficiency (, full load) 83 % Max. output power (see fig. 5) 105 W Max. output power up to 74 C 83 W Primary fuses fuse type 5 x 20 (glass) mm 230 Vac version 250 V/1.6 A, time-lag 115 Vac version 250 V/3.15 A, time-lag...relays 1 and 2 Switching current 100 ma Switching voltage (AC/DC) 100 V "on" resistance 100 RS-485 interfacing Data rate (selectable): EB EB (4.8, 9.6, 19.2) 19.2 kb/s Protocol EB-1 or SNM (EB-2) (1) Environmental & safety Temperature range Full load (11 slots x 9W) o C Operational (max 83W) o C Relative humidity (no cond.) 95 % MTBF hrs Electrical safety IEC UL Listed I.T.E. E Surge protection AC mains 2 kv (IEC ) EMC emission IEC EN Class B FCC pt. 15 Class B EMC immunity IEC , EN ESD 6 kv contact, 8 kv air (IEC ) Mechanical Housing 3 HE, 19" (84TE), 24 cm AC connector type IEC 60320, male RS-485 connectors 9-p sub-d socket Weight (approx.) 4.5 kg Max. number of modules 11 (1) see Supplementary user manuals for remote control (EB) and SNM/EB-2 programming guide Table 8. Technical specifications of the MC 11 AC EB EU Declaration of Conformity The EU Declaration of Conformity for this product is available at Safety and EMC information The equipment described in this manual has been designed and tested according to the IEC safety requirements. It is an IEC safety class 1 product; the ground wire in the line cord must be connected when operating. Warning: Operation of this equipment in a residential environment could cause radio interference. This device has been tested and found to meet the CE regulations relating to EMC and complies with the limits for a Class A device, pursuant to Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against interference to radio communications in any installation. The equipment generates, uses, and can radiate radio frequency energy; improper use or special circumstances may cause interference to other equipment or a performance decrease due to interference radiated by other equipment. In such cases, the user will have to take appropriate measures to reduce such interactions between this and other equipment. Note that the warning above does not apply to TKH Security products which comply with the limits for a Class B device. For product-specific details, refer to the EU Declaration of Conformity. Any interruption of the shielding inside or outside the equipment could make the equipment more prone to fail EMC requirements. To ensure EMC compliance of the equipment, use shielded cables for all signal cables including Ethernet, such as CAT5E SF/UTP or better, as defined in ISO IEC For power cables, unshielded three wire cable (2p + PE) is acceptable Ensure that all electrically connected components are carefully earthed and protected against surges (high voltage transients caused by switching or lightning. The equipment described in this manual is designed for use by properly trained personnel. This means that adjustment, maintenance and repair of the equipment should only be carried out by qualified personnel aware of the hazards involved. For correct and safe use of the equipment and in order to keep the equipment in a safe condition, it is essential that both operating and servicing personnel follow standard safety procedures in addition to the safety precautions and warnings specified in this manual. If there is any doubt regarding the safety of the equipment, do not put it into operation. This might be the case when the equipment shows physical damage or is stressed beyond its tolerable limits (e.g. during storage and transportation). Before opening the equipment, disconnect it from all power sources. After disconnection from its power sources, the capacitors in the equipment may remain charged for some (typically 2-3) minutes. When removing covers or other parts of the equipment, live parts or terminals may be exposed. If the opened, live equipment needs calibration, maintenance or repair, only trained personnel, who are aware of the risks, may perform this. Any interruption of the ground wire inside or outside the equipment, or disconnection of the protective earth terminal, could make the equipment dangerous. Before any connections are made, the equipment must be connected to safety ground. Electrostatic discharge (ESD) can damage or destroy electronic components. Proper precautions should be taken against ESD when opening the equipment. 4

5 Total output power [W] MC10-11 Power supply - Output Power Derating 12. Product disposal Total output power +15V and -15V load combined Recycling This product contains valuable materials which qualify for recycling. In the interest of protecting the natural environment, properly recycling the product at the end of its service life is imperative Ambient Temperature [ C] Figure 5. Power loading of the power supply cabinet 11 slots loaded with 9W modules: Max. ambient 65 C 11 slots loaded with 6W modules: Max. ambient 74 C Accessories: MC 11 EB-2 AC: - power cord - mounting kit - 4-pin Combicon connector 5

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL DVBus 8050-16, 8050-24 and 8050-32 Multiplexer and demultiplexer assemblies for 16-32 video channels USER MANUAL 1. Description DVBus 8050 systems transmit 10-bit digitized video signals over one optical

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

3/4 U CPCI Serial Case System

3/4 U CPCI Serial Case System 3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

3+1 U CPCI Serial System

3+1 U CPCI Serial System 3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,

More information

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

CPCI System Subrack 1 U

CPCI System Subrack 1 U User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this

More information

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Installation instructions Ethernet switch EC / / 2011

Installation instructions Ethernet switch EC / / 2011 Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max. MLP75 Medical Features 3 x 2 x 1 Inches Form factor 75 Watts Convection Approval to EN60601 3 rd Edition Efficiencies upto 93% -40 to 70 degree operating temperature Dual fusing Thermal Shut-Down feature

More information

AO523 Analog Input Module

AO523 Analog Input Module Ordering Data DATA SHEET AO523 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 200 R0001 1SAP 450 200 R0001 AO523, analog output module, 16 AO, U/I, 12 bits

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Safety Standards. Model Number: Unit Weight:

Safety Standards. Model Number: Unit Weight: MEA-250A24C Highlights & Features Meet Efficiency Level VI Safety Approvals to IEC 60601-1 3.1 Ed. & IEC 60950-1 Compliant with IEC 60601-1-2 3 th and 4 th Ed. Requirements IP22 ingress protection rating

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

NI PXI-1042 Series Power Supply Shuttle

NI PXI-1042 Series Power Supply Shuttle USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

D-Link Switch User Manual. Table of Contents

D-Link Switch User Manual. Table of Contents Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs...

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Pro Series DC Power Supply INSTRUCTION MANUAL 855-343-001 Models: ICT690-12S/ICT690-12SB ICT690-24S/ICT690-24SB ICT690-48S/ICT690-48SB ICT1190-12S/ICT1190-12SB ICT1190-24S/ICT1190-24SB

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision Revision 0.20 020-10122009-1415 user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Copyright and Trademarks Copyright 2009 VIA Technologies Incorporated. All rights

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Universal Power Supplies

Universal Power Supplies , Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC

More information

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014 Mounting Instruction Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family RM Sb MACH104-20TX-F USB V.24 1 3 5 7 9 11 13 15 17 19 21 23 Aufkleber MAC-Adresse P 2 4 6 8 10 12 14 16 18 20 22 24

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC) 225 Watt Industrial Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

Neets Switching Relay - 2. Installation manual

Neets Switching Relay - 2. Installation manual Neets Switching Relay - 2 Installation manual Foreword The purpose of this document is to describe how to install and configure Neets Switching Relay 2 with build-in power supply. COPYRIGHT - All information

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply Data sheet Power supply CP-E 48/1.25 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

AC-DC Converter REC K10

AC-DC Converter REC K10 Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,

More information

VME64x System Subrack 8 U

VME64x System Subrack 8 U User s Manual Product No.: Doc-No: 63972-158 Revision: R1.1, November 14, 2008 Rev. Date updated Change R1.0 November 19, 2007 Initial release R1.1 November 14, 2008 Part no. FCM added Impressum: Schroff

More information

AX521 Analog Input/Output Module

AX521 Analog Input/Output Module Ordering Data DATA SHEET AX521 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 100 R0001 1SAP 450 100 R0001 AX521, analog input/output module, 4 AI,

More information

COGNEX. Checker SensorView. Quick Reference Guide

COGNEX. Checker SensorView. Quick Reference Guide COGNEX Checker SensorView Quick Reference Guide 890 SensorView 890 Overview SensorView 890 provides self-contained IP-65 touchscreen configuration, control, and monitoring of one or more Checker 4G series

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

Industrial Power Supplies

Industrial Power Supplies 50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply Data sheet Power supply CP-E 24/0.75 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature User Manual EKI-6528TI/ 6528TPI EN50155 8-port M12 Unmanaged/ PoE Switch with Wide Temperature Copyright The documentation and the software included with this product are copyrighted 2006 by Advantech

More information

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the

More information

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing The TSR10 is a 10 kw, 3-phase input voltage 360-440 VAC power supply with an adjustable DC output voltage between 0.5 V and 50 V and output current between 0.5 A and 200 A. The power supply has been designed

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter

More information

Industrial Power Supplies

Industrial Power Supplies , Rugged metal case for harsh industrial environments Industrial operating temperature range: 25 C to +70 C Overload and and overtemperature protection Power boost up to 120 % Power-Good signal Shock and

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL 4.01.0067.20000 3.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

EZmoto V4.1 Product description Rev. 2 30/07/2015

EZmoto V4.1 Product description Rev. 2 30/07/2015 EZmoto V4.1 Product description Rev. 2 30/07/2015 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

PCT2000. User Manual. Precision current transducer 2000 A

PCT2000. User Manual. Precision current transducer 2000 A PCT2000 User Manual PCT2000 Precision current transducer 2000 A User Manual Status: November 6, 2018 Copyright 2018 ZES ZIMMER Electronic Systems GmbH Pfeiffstraße 12 61440 Oberursel (Taunus), Germany

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

AX522 Analog Input/Output Module

AX522 Analog Input/Output Module Ordering Data DATA SHEET AX522 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 000 R0001 1SAP 450 000 R0001 AX522, analog input/output module, 8 AI

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

PDD-300 pulsed diode driver

PDD-300 pulsed diode driver rev 1.08 / 2019 02 13 PDD-300 pulsed diode driver User manual Warning! This equipment may be dangerous. Please read user manual before starting operations. Important note. Please measure output with adequate

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

CPCI System Subrack 3 U

CPCI System Subrack 3 U User s Manual Product No.: Doc-No: 63972-224_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff

More information