Making the impossible data center a reality.
|
|
- Nathaniel Terry
- 5 years ago
- Views:
Transcription
1 United Nations ITU WSIS 2016 WINNER E-Environment Malaysia s First Win 2015 ASIA PACIFIC WINNER 2015 Best of Sustainability and Environmental Technology WINNER 2015 Best of Sustainability and Environmental Technology MERIT 2015 Best of Start-Up Companies Making the impossible data center a reality.
2 Data Centers Face Many Challenges
3 We Removed Air From The Equation, Solving Multiple Data Center Problems.
4 CURRENT INDUSTRY FACT IT Power = 1 Watt Cooling Power = 1 Watt Power Usage Effectiveness (PUE) = 2.0 HOW? We do away with CRAC, CRAH, Chillers or Fans. Air is a poor heat conductor. Kept at 21 C (7 C at chiller) to keep servers cool. [Eco 2 ] Economical & Eco-Friendly [Eco 2 ] FACT IT Power = 0.9 Watt Cooling Power = 0.1 Watt Power Usage Effectiveness (PUE) = 1.1 WHAT!!? Submersion cooling = 1356x more efficient at holding heat than air. [Eco 2 ] at 38 C is as efficient as 21 C air.
5
6 CASE STUDY: CRF DATA CENTER What Is Eco 2?
7 CASE STUDY: CRF DATA CENTER What Is Eco 2?
8 CLOUD IN A BOX POWERED BY Eco 2 DESIGN BRIEF: THE MOST COST EFFICIENT MODULAR GREEN DATA CENTER IN THE WORLD MOBILE: Fast and low cost transportation to provide computing resources in any location. MODULAR: Lego blocks methodology. koolkubes can be stacked up 7 levels high. Smallest Deployment Unit is 1/3 of a rack. PLUG & PLAY: Just plug in power and bandwidth. LOW CAPEX: Verified lowest capex globally & lowest opex regionally. Mikros Uses ambient MICRO DATA CENTER cooling with POWERED BY Eco 2 Eco 2 coolant. Rugged and weatherproof. PUE= kw, scalable to 6372kw Up to U Servers 480sf vs 1450sf conventional US$3 per watt CAPEX vs $10-$20/w The latest mobile applications needs ultra low latency, 15ms vs current 200ms. This is the biggest challenge of the industry right now. To fix this, the Internet needs to be redesigned or DCs need to be closer to users. We bring DCs closer.
9 Comparing With The Existing 1.6 Billion Square Feet of Global Data Center Space Using Air Cooling Component Air Cooling Eco 2 CRAC/CRAH REQUIRED NOT REQUIRED CHILLER REQUIRED NOT REQUIRED LARGE BACKUP GENERATOR AIR FLOW ENGINEERING FULL SIZE REQUIRED HALF SIZE NOT REQUIRED 70% less capital expenditure 50% less energy bill 50% less carbon footprint 80% Faster Deployment 30% Less Equipment Failure 40% Cheaper HDDs 8 Hours Disaster Recovery- Response Time Dust Free Operations Noise Free Operations Eco 2 vs Air Cooling vs Transformer Oil HOT/COLD AISLE REQUIRED NOT REQUIRED RAISED FLOOR/SPECIAL FLOOR REQUIRED NOT REQUIRED RACK RAILS REQUIRED NOT REQUIRED
10 Comparing With The Existing 20,000 Square Feet of Global Data Center Space Using Fluid Submersion Feature Eco 2 Transformer Oil DESIGN FOR ICT FOR TRANSFORMERS HEAT CAPACITY 118KW 100KW DIELECTRIC CAPACITY BREAKDOWN AT 75KV BREAKDOWN AT 45KV FLASH POINT >220 C >145 C FIRE POINT TOXICITY >220 C SAFE FOR HUMANS, ALL ADDITIVES FDA APPROVED >185 C WHO GROUP 1 CARCINOGEN FOR HUMAN TOTAL INFRA COSTS US$2/WATT US$4/WATT RENEWABLE YES NO SUSTAINABLE YES NO BIO-DEGRADABLE YES NO 66% more dielectric - capacity 18% more heat - conductivity 50% less capital - expenditure 51% higher flash point 19% higher fire point International Agency for Research on Cancer found Polycyclic Aromatic Hydrocarbons
11 MAJOR COST SAVINGS E.G: 0.5 MW (MEDIUM DC) CAPEX OPEX TCO ROI Eco 2 = US$1.0M Traditional = US$3.35M Eco 2 Cooling = US$87.6K /yr Air Cooling = US$876K /yr Eco 2 Maint. = US$125K /5yrs Air Cooling Maint. = US$525K /5yrs Eco 2 Savings = US$788K /yr 70% Lower* 90% Lower + 10% Lower IT** 76% Lower 15 Months *Based on 500kw IT equipment capacity. Includes racks & complete cooling. Excludes building, raised flooring, ICT, etc. **Based on US$0.20 per kwh, lower IT because of fans removals.
12 COMPARING SPECIFIC DEPLOYMENTS FOR MEGA DCs Eco 2 Conventional A Conventional B Conventional C Total Power Needed 24.3 MW 36MW 43MW 48MW Power Usage Effectiveness (PuE) Design Total Critical IT Load MW (10% less IT power due to fans removal) 24MW 24MW 24MW Cooling & Auxiliaries Load 2.7MW 12MW 19MW 24MW Cooling & Racking Infrastructure CapEX US$2 per IT Watt = US$48,000,000 US$6.5 per IT Watt = US$156,000,000 US$6.5 per IT Watt = US$156,000,000 US$6.5 per IT Watt = US$156,000,000 Annual Total DC Energy OpEX 212,868,000KWh x 0.45sen = RM95,790, ,360,000KWh x 0.45sen = RM141,912, ,680,000KWh x 0.45sen = RM169,506, ,480,000KWh x 0.45sen = RM189,216,000 Annual DC Carbon Footprint 157,735,188 MT CO 2 233,681,760 MT CO 2 279,119,880 MT CO 2 311,575,680 MT CO 2
13 STAYING TRUE TO OUR MISSION, ALWAYS. We are environmental stewards representing the ICT industry with the mission of helping preserve Earth for our future generations. One DC at a time, low cost. THANK YOU FOR YOUR TIME.
PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES
PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more
More informationHow Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October
How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion
More informationFREEING HPC FROM THE DATACENTRE
FREEING HPC FROM THE DATACENTRE ku:l sistem TM COOLING REDEFINED www.iceotope.com ku:l sistem removes the need for inefficient air cooling technologies FREEING HPC FROM THE DATACENTRE Iceotope s patented
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationEP s approach to Power & Energy efficiency in DCs & paradigms
DG for Innovation and Technological Support EP s approach to Power & Energy efficiency in DCs & paradigms Presentation Presentation subtitle subtitle or lead-in or lead-in that says that what says what
More informationApplication of Green Technology For Data Centre
Application of Green Technology For Data Centre Steven So Vice President Data Centre Business Cloud Business Division NTT Com Asia Limited 25 Sep 2013 Today s Agenda Why? How? What? Business Drivers
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationDC Energy, Efficiency Challenges
DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in
More informationSmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity
SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up Solutions For Business-Critical Continuity Deploy a Fully Configured Data Center in Just Weeks Efficiency. Capacity. Availability.
More informationNext Generation Cooling
Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack
More informationNREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions
NREL Validates LCS Technology PRESENTED BY Herb Zien CEO, LiquidCool Solutions Learning Objectives As much as 40% of data center power is used to circulate air, and fans in a typical 30-megawatt data center
More informationSmartRow Solution Intelligent, Integrated Infrastructure for the Data Center
SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center Deploy a Fully Configured Data Center in Just Weeks Availability, Capacity, Efficiency. You need them and now you can have them
More informationThe End of Redundancy. Alan Wood Sun Microsystems May 8, 2009
The End of Redundancy Alan Wood Sun Microsystems May 8, 2009 Growing Demand, Shrinking Resources By 2008, 50% of current data centers will have insufficient power and cooling capacity to meet the demands
More informationVirtualization and consolidation
Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical
More informationCapacity and Power Management: The Forgotten Factors in Disaster Recovery Planning Presented by: Clemens Pfeiffer CTO Power Assure, Inc.
Capacity and Power Management: The Forgotten Factors in Disaster Recovery Planning Presented by: Clemens Pfeiffer CTO Power Assure, Inc. The Purpose of a Data Center Provide IT equipment a healthy environment
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationDCIM Data Center Infrastructure Management Measurement is the first step
DCIM Data Center Infrastructure Management Measurement is the first step Presented by Julius Neudorfer Sponsored by DCIM Data Center Infrastructure Management Measurement is the first step Presented by
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationPlanning a Green Datacenter
Planning a Green Datacenter Dr. Dominique Singy Contribution to: Green IT Crash Course Organisator: Green IT Special Interest Group of the Swiss Informatics Society ETH-Zurich / February 13, Green Data
More informationEaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..
Eaton 93PM: Value, Benefits, and Features 93PM value proposition The Eaton 93PM UPS combines unprecedented efficiency, reliability and vertical or horizontal scalability with eyecatching design. A space-saving,
More informationINNOVATE DESIGN APPLY.
INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues
More informationHIGH DENSITY RACK COOLING CHOICES
WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES
More informationINNOVATE DESIGN APPLY.
INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues
More informationSmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity
SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks Solutions For Business-Critical Continuity Deploy An Efficient and Flexible Row-Based Infrastructure Efficiency. Capacity.
More informationData Center Temperature Design Tutorial. Ian Seaton Chatsworth Products
Data Center Temperature Design Tutorial Ian Seaton Chatsworth Products What are we going to do today? Explore a process for determining what data center operating temperature will deliver the best total
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationTrends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon
Trends and legislations in the data center industry Pär Åberg - Business Development Manager - Swegon DC Fastest growing industry in the world 2 Fast and furious 3 IT services in the driving seat of the
More informationMake the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group
Make the most of your Energy from Power Plant to Plug Chris Simard, Regional Director Field Sales Group We see six key challenges facing our world Connectivity Simplicity Globalization Demand For Energy
More informationHow High-Density Colocation and Enhanced Visibility Improve Business Performance
How High-Density Colocation and Enhanced Visibility Improve Business Performance Steven So Vice President Data Center Business Cloud Business Division NTT Com Asia Limited 11 Sep 2015 NTT Communications
More informationProduct Brochure Eaton 93PR UPS kw
Product Brochure Eaton 93PR UPS 25-200 kw For more than 50 years, Eaton has been safeguarding the critical systems of businesses across the globe. Whether protecting a single desktop or the largest data
More informationWHITE PAPER. Oil Immersion Cooling for Today s Data Centers. An analysis of the technology and its business
WHITE PAPER Oil Immersion Cooling for Today s Data Centers An analysis of the technology and its business In response to a growing demand for computing power and technological advancement, server densities
More informationModular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered
Modular & Mobile Data Centre Solutions www.workspace-technology.com www.mobiledatacentre.com Data Centre Solutions Expertly Engineered ...providing clients with complete agility, delivering a scalable
More informationPros and Cons of Various DC Distribution Architectures
Pros and Cons of Various DC Distribution Architectures Source: Solar Powered Datacenter by Google Randy Malik Power Technology And Qualification IBM RTP Raleigh NC Rick Fishbune Power Technology And Qualification
More informationHot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit
Hot vs Cold Energy Efficient Data Centers - SVLG Data Center Center Efficiency Summit KC Mares November 2014 The Great Debate about Hardware Inlet Temperature Feb 2003: RMI report on high-performance data
More informationThe Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation
Ee The Efficient Enterprise All content in this presentation is protected 2008 American Power Conversion Corporation Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic!
More informationHow green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.
How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter Summary Diesel Rotary UPS (DRUPS) systems are best in class regarding energy
More informationMicrosoft s Cloud. Delivering operational excellence in the cloud Infrastructure. Erik Jan van Vuuren Azure Lead Microsoft Netherlands
Microsoft s Cloud Delivering operational excellence in the cloud Infrastructure Erik Jan van Vuuren Azure Lead Microsoft Netherlands 4 Megatrends are driving a revolution 44% of users (350M people) access
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationDealing with the Density Dilemma
W H I T E PA P E R Dealing with the Density Dilemma How To Prepare Your Data Center Now For Next-Gen Application Architectures in AI, Microservices and IoT. YEARS 11525 Stonehollow Drive, Suite A-150 Austin,
More informationSchneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions
Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in
More informationInterested in conducting your own webinar?
Interested in conducting your own webinar? Email webinars@bnpmedia.com July 17, 2012 TCO in the Data Center Audio Abstract Presenter Info Slides Handouts Group Chat Q & A Live Twitter Feed Help Survey
More informationSmartCabinet Intelligent, Integrated Containment for IT Infrastructure
TM SmartCabinet Intelligent, Integrated Containment for IT Infrastructure WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds,and services mission critical technologies that enable vital
More informationHighly Efficient Power Protection for High Density Computing Applications
Highly Efficient Power Protection for High Density Computing Applications IB Power and Cooling Symposium Lennart Jonsson Eaton Corporation 2007 Eaton Corporation. All rights reserved. Impact of High Density
More information18 th National Award for Excellence in Energy Management. July 27, 2017
18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months
More informationData center redundancy. Air traffic High-speed pipes. Training Design. Costs. Guy with a wrench. Terrorism
Data center redundancy Costs Training Design Air traffic High-speed High speed pipes Guy with a wrench Terrorism Fire Communications Backup and Network power Power di t ib ti distribution Security Governance
More informationHigh Density Cooling Solutions that work from Knurr Kris Holla
High Density Cooling Solutions that work from Knurr Kris Holla The Heat Goes On Ó by Knürr A An International Company Ranked #3 in the world Founded 1931 Strong international setting in over 32 countries
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationReducing Data Center Cooling Costs through Airflow Containment
FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental
More informationEcolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001
Ecolibrium OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 Cloud control Keeping data centres cool. COVER FEATURE Cloud control Such is the growth in data centres globally
More informationCompute Engineering Workshop March 9, 2015 San Jose
Compute Engineering Workshop March 9, 2015 San Jose Compute Engineering Workshop Microsoft OCS Distributed Local Battery Energy Power System Shaun L. Harris Director of Hardware Engineering Windows Cloud
More informationSMARTAISLE Intelligent, Integrated Infrastructure for the Data Center
SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center SMARTAISLE Deploy an Efficient and Flexible Row-Based Infrastructure Efficiency. Capacity. Availability. Control. The SmartAisle infrastructure
More informationData Center UPS Systems Why 1% Efficiency Matters
Data Center UPS Systems Why 1% Efficiency Matters Harry Handlin Director Critical Power Applications, September 18, 2014 Key Questions / Problems Addressed: Why efficiency gains of as little as 1 percent
More informationDATA CENTER COLOCATION BUILD VS. BUY
DATA CENTER COLOCATION BUILD VS. BUY Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for
More informationData Center Design: Power, Cooling & Management
Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1 UPS topologies Large Free standing Static Switches
More informationEvaporative free air cooling technology Providing evaporative free air cooling solutions.
Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free
More informationData Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala
Data Centre Energy & Cost Efficiency Simulation Software Zahl Limbuwala BCS Data Centre Simulator Overview of Tools Structure of the BCS Simulator Input Data Sample Output Development Path Overview of
More informationSMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER
SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationEcoflair Air Economizers
Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your
More informationSwitch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationPLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy
PLAYBOOK F O R C H A N G E How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy The world is becoming more digital every day. The demand for feature-rich,
More informationIT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day
IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm
More informationHow to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC
12 Technology for energy efficiency www.circutor.com Technical article Francisco Domínguez Network Quality Division How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing
More informationHPC Solutions in High Density Data Centers
Executive Report HPC Solutions in High Density Data Centers How CyrusOne s Houston West data center campus delivers the highest density solutions to customers With the ever-increasing demand on IT resources,
More informationRittal Cooling Solutions A. Tropp
1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.
More informationHow much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)
How much power?! Data Centre Efficiency The US EPA found in 2006 data centres used 1.5% of total US consumption (5) For Bangor University data centres use approximately 5-10% of the total university electricity
More informationINT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)
INT 492 : Selected Topic in IT II (Data Center Design) 3(3-0-6) การออกแบบระบบศ นย สารสนเทศ Overview The American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Technical Committee
More informationSmart Solutions Intelligent, Integrated Infrastructure for the Data Center
Solutions For Business-Critical Continuity Smart Solutions Intelligent, Integrated Infrastructure for the Data Center DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Deploy
More informationOne Stop Cooling Solution. Ben Tam Business Development Manager
One Stop Cooling Solution Ben Tam Business Development Manager Agenda One Stop Cooling Solution Challenges Customers Are Facing Today Rack / Row / Room Solution Keynotes New Product Launch Slide 2 2 One
More informationOptimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.
Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery
More informationMaximise Data Center Value
Maximise Data Center Value with Higher Density Infrastructure Dramatic cost savings enabled; Requires solving unique electrical + cooling challenges; 08 December 2015 Speaker gokhan.gulal@4g.net.tr Genel
More informationData Center Infrastructure Management (D.C.I.M.)
Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)
More informationVodafone Sustainability & Innovation in emerging market
Second Green Power for Mobile Regional Special Working Group Hosted by Safaricom 15 th 16 th March 2011, Mombasa, Kenya Vodafone Sustainability & Innovation in emerging market Mohammed Belfqih Senior Manager
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationIndustry leading low energy evaporative fresh air cooling.
Industry leading low energy evaporative fresh air cooling. Freecool Evaporative Free Air Cooling by Workspace Technology delivers innovative low energy cooling for a range of applications including data
More informationENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012
ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012 Robert (RJ) Meyers Data Center Products Lead ENERGY STAR Program US Environmental Protection Agency 1 Overview Main
More informationSystem Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks
Liquid Cooling for Data Centers System Overview The Chilldyne Cool-Flo System is a direct-to-chip liquid cooling system that delivers coolant under negative pressure. Chilldyne s technologies were designed
More informationE f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n
E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; 4 0 0 V D C p o w e r f e e d s o l u t i o n Juha Klemola / HW Architect / Nokia Introduction to the challenge Datacenter
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More informationAir Containment Design Choices and Considerations
Air Containment Design Choices and Considerations Brad J. Murphy, A.Sc.T., ATS, DCDC, DCEP, Principal Racon Data Centres Introduction Introduction Air containment design must consider many different factors
More informationPower Consumption in the Data Center. Green Concepts
Power Consumption in the Data Center Green Concepts What is your Energy Saving Strategy? Buying Energy Efficient Equipment (EEE) 46% Say Yes to Green Technology Information Week Research Green Data Center
More informationValidating Hyperconsolidation Savings With VMAX 3
Validating Hyperconsolidation Savings With VMAX 3 By Ashish Nadkarni, IDC Storage Team An IDC Infobrief, sponsored by EMC January 2015 Validating Hyperconsolidation Savings With VMAX 3 Executive Summary:
More informationLecture 20: WSC, Datacenters. Topics: warehouse-scale computing and datacenters (Sections )
Lecture 20: WSC, Datacenters Topics: warehouse-scale computing and datacenters (Sections 6.1-6.7) 1 Warehouse-Scale Computer (WSC) 100K+ servers in one WSC ~$150M overall cost Requests from millions of
More informationCooling Solutions & Considerations for High Performance Computers
Cooling Solutions & Considerations for High Performance Computers White Paper 6 Revision 1 By Rich Whitmore Executive summary The recent advances in high performance computing have driven innovations not
More informationCannon T4 Modular Data Center (MDC)
SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4
More informationDATA CENTER LIQUID COOLING
DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid
More informationPower & Cooling Considerations for Virtualized Environments
Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted
More informationCost Model Energy Benefits DirectAire & SmartAire Overview & Explanation
Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation A cost model (See figure 1) has been created to provide the user a simplified method for directly comparing the energy cost of a
More informationNewave s approach for protecting mission critical application
ABB Technology Show, May 2013 Newave s approach for protecting mission critical application May 13, 2013 Slide 1 Contents Newave s company overview Electricity environment and trend Data Centre environment
More informationInnovative Data Center Efficiency Techniques. Michael K Patterson, PhD PE Eco-technology Program Office Intel Corporation
Innovative Data Center Efficiency Techniques Michael K Patterson, PhD PE Eco-technology Program Office Intel Corporation 1 Alternate titles.. Crisis or opportunity? Never build a new data center! Improve
More informationExcool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling
Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Data Centre Solutions Expertly Engineered Indirect Adiabatic and Evaporative
More informationTopics. CIT 470: Advanced Network and System Administration. Google DC in The Dalles. Google DC in The Dalles. Data Centers
CIT 470: Advanced Network and System Administration Data Centers Topics Data Center: A facility for housing a large amount of computer or communications equipment. 1. Racks 2. Power 3. PUE 4. Cooling 5.
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationPartner Introduction
P R E S E N T S Partner Introduction September 16, 2013 Today s Agenda The Market Opportunity The Cooling Capacity Factor (CCF) New service Benefits to Upsite Partners How to Sell Launch Plan & Support
More informationPOWERING A CONNECTED ASIA. Pacnet Hong Kong DataSpace1 Technical Specifications. Advanced Data Center Facility for Multi-Site Enterprises
POWERING A CONNECTED ASIA Pacnet Hong Kong DataSpace1 Technical Specifications Advanced Data Center Facility for Multi-Site Enterprises Pacnet Hong Kong DataSpce1 (HKDS1) provides an ideal environment
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More information2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.
[Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL
More information