Table of Contents. 1 Introduction. 2 Facility and Space Planning Requirements

Size: px
Start display at page:

Download "Table of Contents. 1 Introduction. 2 Facility and Space Planning Requirements"

Transcription

1 1 Introduction 1.1 Purpose and Scope Telecommunications Service Provider (TSP) Role Equipment Manufacturer Role Application Guidelines Central Offices (COs) and Similar Facilities Commercial Buildings Non-Environmentally Controlled Locations Other Locations Reasons for, Issue Structure and Use of This Document Related Documents Requirements Terminology Requirement Labeling Conventions Numbering of Requirement and Related Objects Requirement, Conditional Requirement, and Objective Identification Supplier-Provided Documentation Facility and Space Planning Requirements 2.1 Equipment Frames and Lineup Conformity Floor Plans Vertical Space Allocation Equipment Frame Dimensions Special Cases Equipment Frame Floor Loading Space Planning for Distributing Frames (DFs) Space Planning for Centralized DC Power Plant Equipment Cable Distribution Systems (CDSs) CDS Requirements General Overhead Cable Distribution Cable Distribution Under Raised Floor Cable Pathways Over Equipment Frame Areas Elements of Allocation Plan System Cable Racks Via Cable Racks Lights Cable Pathways Over Distributing Frame (DF) Areas CDS Floor Load and Support Operations Support Systems (OSSs) Cable Entrance Facility (CEF) CEF Spatial Requirements CEF Loading Requirements Summary of Equipment Allocations Equipment Room Cooling Systems Central Cooling Systems Distributed Cooling Systems v

2 Issue 4, April Hot Aisles and Cold Aisles Airborne Contaminants Within the Equipment Room Contamination Classes Gaseous Contamination Levels Measurement of Contaminant Levels Illumination of Equipment Spaces Illumination Criteria for Central Office (CO) Lighting Systems Quantity of Light Luminance Ratios Color of Light Illumination Test Method for Central Office (CO) Lighting Systems Test 1 Console Illumination, Readability, and Glare Tests Test 2 Lighting System Tests Equipment Spatial Design Requirements for Frames and Chassis 3.1 Equipment Frame Nomenclature Equipment Frame Floor Mounting Equipment Frame Junctioning Equipment Frame Dimensions Equipment Frame Dimensions Open-Style Racks Equipment Frame Dimensions Other Rack Styles Equipment Frame Dimensions Shipping Equipment Frame End Guards Equipment Frame Dimensions Special Cases Equipment Frame Cable Management Provisions Equipment Frame Interface With Cable Rack Equipment Frame Weight Equipment Frame Support of CDS and Lights AC Convenience Outlets Within Equipment Frames Other Frame Types Distributing and Interconnecting Frames (DFs and IFs) Distributing Frames (DFs) Interconnecting Frames (IFs) DC Power Plant Equipment Frames Equipment-Chassis Mounting Requirements Network Equipment Environmental Criteria 4.1 Temperature, Humidity, and Altitude Criteria Transportation and Storage Environmental Criteria Low-Temperature Exposure and Thermal Shock High-Relative-Humidity Exposure High-Temperature Exposure and Thermal Shock Operating Temperature and Humidity Criteria Altitude Temperature Margin Evaluation Fan-Cooled Equipment Criteria Equipment Fan-Performance Criteria Equipment Fan-Filter Criteria Heat Dissipation and Energy Efficiency Surface Temperature vi

3 4.1.8 Equipment Airflow Fire Resistance Fire-Resistance Rationale Equipment Assembly Fire Tests Frame-Level Fire-Resistance Criteria Shelf-Level Fire-Resistance Criteria Smoke and Self-Extinguishment Criteria Use of Fire-Resistant Materials, Components, Wiring, and Cable Material/Components Fire-Resistance Criteria Wire and Cable Between Frames Optical Fiber Cable Trays and Raceways Ignitability Requirements for Ancillary Materials Equipment Handling Criteria Packaged Equipment Shock Criteria Category A Containers Category B Containers Unpackaged Equipment Shock Criteria Earthquake, Office Vibration, and Transportation Vibration Earthquake Environment and Criteria Earthquake Environment Physical Performance Criteria Functional Performance Framework and Anchor Criteria Wall-Mounted Equipment Anchor Criterion Office Vibration Environment and Criteria Office Vibration Environment Physical Performance Criteria Functional Performance Criteria Transportation Vibration Criteria Transportation Environment Airborne Contaminants Environmentally Controlled Space and Sealed Network Cabinets Ventilated Outside Plant (OSP) Equipment Acoustic Noise Illumination Criteria for Network Equipment Surface Reflectance and Color Glare Network Equipment Environmental Test Methods 5.1 Temperature, Humidity, and Altitude Test Methods Transportation and Storage Test Methods Low-Temperature Exposure and Thermal Shock High-Relative-Humidity Exposure High-Temperature Exposure and Thermal Shock Operating Temperature and Relative Humidity Operating Altitude Temperature Margin Determination Operation With Fan Failure Rate of Heat-Dissipation Calculation Procedure Surface Temperature Test Procedures vii

4 Issue 4, April Infrared Measurement Equipment Contact Measurement Equipment Equipment Evaluation Procedures Fire Test Methods Sample Configuration Testing Clarification Circuit Board Removal Adjacent Printed Wiring Boards (PWBs) in Close Proximity Case 1 No Mezzanine Cards Case 2 Mezzanine Card Case 3 Larger or Multiple Mezzanine Cards Adjacent Printed Wiring Boards (PWBs) Not in Close Proximity ATIS Test Deviation Fan-Powering Options Telcordia Needle Flame Test Application to Individual Components In-Situ Application to Individual Components Guidelines for Re-Testing to Address Product Changes Test Reporting Additions Handling Test Methods Handling Drop Tests Packaged Equipment Category A Container Test Procedure Category B Container Test Procedure Unpackaged Equipment Drop Tests Test Procedure Equipment and Field Replaceable Units (FRUs) Weighing Less Than 25 kg (55.1 lb) Test Procedure Equipment and Field Replaceable Units (FRUs) Weighing 25 kg (55.1 lb) or More Earthquake, Office Vibration, and Transportation Vibration Test Methods Earthquake Test Methods Test Plan Laboratory Equipment Test Configuration Static Test Procedure Waveform Test Procedure Test Report Office Vibration Test Procedure Test Procedure All Frame-Mounted or Wall-Mounted Equipment Transportation Vibration Packaged Equipment Airborne Contaminants Test Methods Scope Gaseous Contaminants Test Method Two Cleaning Procedures for Copper Coupons Test Procedure Measuring Parameters Safety Procedures for Testing Gaseous Contaminants Performance Criteria Test Report Hygroscopic Dust Test Method Sample Selection Sample Handling Test Sequence viii

5 Performance Criteria Test Report Acoustical Measurement Methodology Procedure for Nominal, 27 C Operating Conditions: Test Room at 27 C Procedure for Nominal, 27 C Operating Conditions: Test Room at Other Than 27 C Procedure for Nominal, 23 C Operating Conditions Procedure for High-Temperature Operating Conditions Illumination Test Methods for Network Equipment Equipment Assembly Readability, Glare, and Reflectance Tests Test Procedure Equipment Assembly Readability and Glare Test Procedure Equipment Surface Reflectance Appendix A: References A.1 Telcordia Documents A 1 A.2 Other Referenced Documents or Material A 2 A.3 Telcordia Document Sets Family of Requirements (FR) and Family of Documents (FD) A 5 A.4 Telcordia Reference Notes A 7 A.4.1 Contact Telcordia Customer Service A 7 A.4.2 Order Documents Online From the Telcordia Information SuperStore.. A 7 A.4.3 Web Sites for Generic Requirements Information A 8 A.4.4 Licensing Agreements for Telcordia Documents A 8 Appendix B: Acronyms Requirement-Object Index ix

2 Telecommunications Data Center Facility Requirements

2 Telecommunications Data Center Facility Requirements Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................

More information

Table of Contents. 1 Introduction. 2 Reliability Assurance Overview and Philosophy. 3 Basic Reliability Assurance Program Requirements

Table of Contents. 1 Introduction. 2 Reliability Assurance Overview and Philosophy. 3 Basic Reliability Assurance Program Requirements Reliability Requirements for Passive Optical Components GR-1221-CORE Table of Contents Table of Contents 1 Introduction 1.1 Scope and Purpose.................................. 1 2 1.2 Changes in the Document..............................

More information

Review of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014

Review of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014 Review of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014 Telcordia Contact: Ernie Gallo Director Telcordia Network

More information

Generic Requirements for Optical Network Unit (ONU) Closures

Generic Requirements for Optical Network Unit (ONU) Closures Generic Requirements for Optical Network Unit (ONU) Closures Preface... Preface 1 1. Introduction...1 1 1.1 Purpose and Scope...1 1 1.2 Organization...1 1 1.3 Summary of Changes...1 2 1.4 Target Audience...1

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER 2 7 CHAPTER This chapter describes the Cisco ME 00 series Ethernet switches and contains these sections: Cisco ME 2 Ethernet Switch (ME-C2GS-8S), page - Cisco ME 2 Ethernet Switch (ME-C2GT-8S), page -7

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks Guidelines June 2000 Prepared by: Storage Products Group Compaq Computer Corporation Contents Introduction...3 Rack Warnings...4 Telco Rack Option Kit for Compaq ProLiant DL360 Server Installation...5

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications

More information

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Reducing Energy Consumption with

Reducing Energy Consumption with Reducing Energy Consumption with Passive Cooling Ian Cathcart, RCDD Technical Support Manager Technical Support Manager Chatsworth Products, Inc. Thermal Management: Mission Critical Data center heat loads

More information

MX480 3D Universal Edge Router

MX480 3D Universal Edge Router MX480 3D Universal Edge Router Hardware Guide Published: 2013-08-29 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net This product includes

More information

Generic Requirements for Singlemode Fiber Optic Switches

Generic Requirements for Singlemode Fiber Optic Switches 1. Introduction... 1 1 1.1 Purpose and Scope... 1 2 1.2 Target Audience... 1 2 1.3 Structure of This Document... 1 3 1.4 Requirements Terminology... 1 3 1.5 Requirement Labeling Conventions... 1 4 1.5.1

More information

STANDARD MEDIA CONVERTER SWITCHES

STANDARD MEDIA CONVERTER SWITCHES 2005. All rights reserved. Black Box Corporation. Black Box Network Services (UK) Ltd 464 Basingstoke Road Reading, berkshire, RG2 0BG Tech Support: 0118 965 6000 www.blackbox.co.uk STANDARD MEDIA CONVERTER

More information

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE:

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

S5048F-ON. Set-up Guide

S5048F-ON. Set-up Guide S5048F-ON Set-up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

Specifications and Part Numbers

Specifications and Part Numbers This appendix provides information on the part numbers of the router variants, SFP modules, product, power, and environmental specifications of the Cisco ASR 901S Series Aggregation Services Router components.

More information

Data Centre Infrastructure

Data Centre Infrastructure Data Centre Infrastructure Aisle Containment Solution Aisle Containment is a popular way of cooling high density server installations. Aisle containment can work in two ways: Cold Aisle Containment where

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

1.0 Executive Summary

1.0 Executive Summary Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service

More information

Dell Networking S4100-ON Series. Set-Up Guide

Dell Networking S4100-ON Series. Set-Up Guide Dell Networking S4100-ON Series Set-Up Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Project Olympus 2U Server Mechanical Specification

Project Olympus 2U Server Mechanical Specification Project Olympus 2U Server Mechanical Author: Anand Kulkarni, Senior Mechanical Engineer, Microsoft Revision History Date Description 11/1/2017 Version 1.0 Ready for Project Olympus github ii November 1,

More information

LCP Hybrid Efficient performance with heat pipe technology

LCP Hybrid Efficient performance with heat pipe technology LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative

More information

Cisco Nexus 7700 Switches Data Sheet

Cisco Nexus 7700 Switches Data Sheet Data Sheet Cisco Nexus 7700 Switches Data Sheet Product Overview The Cisco Nexus 7000 Series Switches are the foundation of the Cisco Unified Fabric solution. Designed to meet the requirements of mission-critical

More information

Installation Job Aid for Avaya Virtual Services Platform 8400

Installation Job Aid for Avaya Virtual Services Platform 8400 Installation Job Aid for Avaya Virtual Services Platform 8400 Support Release 4.2 NN47227-305 Issue 01.06 June 2015 Go to the Avaya Support website at http://support.avaya.com for the most up-to-date documentation,

More information

VEP4600. Setup Guide

VEP4600. Setup Guide VEP4600 Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Site Preparation for ClearCube Installation. Rev. F

Site Preparation for ClearCube Installation. Rev. F Site Preparation for ClearCube Installation Rev. F EXECUTIVE SUMMARY Because of the centralized nature of the ClearCube architecture, installation of the system requires a certain degree of site preparation.

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Newark, Delaware Architectural Engineering Senior Thesis Portfolio Telecommunications System Design The represents the advancement of solar design in our world today. The building itself is an example of this. A Headquarters this dedicated to moving into the future should

More information

EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL

EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL ESP-001 Form EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL Acoustic Noise Engineering Data Physical Data Equipment System Manufacturer: Date: Product Name: Equip. Functional Description and

More information

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. DATA CENTRE COOLING SYSTEM A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. 1. Cooling Optimized to Electronic

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

Project Olympus 1U Server Mechanical Specification

Project Olympus 1U Server Mechanical Specification Project Olympus 1U Server Mechanical Author: Anand Kulkarni, Senior Mechanical Engineer, Microsoft Open Compute Project Project Olympus 1U Server Mechanical Revision History Date Description 10/24/16 Version

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 18010 First edition 2002-05 Information technology Pathways and spaces for customer premises cabling ISO/IEC 2002 All rights reserved. Unless otherwise specified, no part

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

V-Built Custom Preconfigured Solutions

V-Built Custom Preconfigured Solutions WWW.SIEMON.COM V-Built Custom Preconfigured Solutions 8 One Part Number, One Price Ready to Roll Available with any Siemon cabinet, rack or enclosure, Siemon s V-Built Custom Preconfigured Solutions are

More information

Rack & Enclosure Systems

Rack & Enclosure Systems Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Product availability : Stock - Normally stocked in distribution facility Price* : 1468.00 USD Main Range

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer. Facility Guidelines This section provides details relating to site selection, site preparation and readiness of the facility to accept and install the ProJet Professional Printing System. Discuss appropriate

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

CCBC is equipped with 3 computer rooms, one at each main campus location:

CCBC is equipped with 3 computer rooms, one at each main campus location: Policy: Computer Room Procedures Policy: Draft 12/14/2009 1.0 Purpose The purpose of this document is to establish procedures for the Community College of Baltimore County (CCBC) Information Technology

More information

6. Secured Collocation Open Physical Environment (SCOPE) 6.1 Description

6. Secured Collocation Open Physical Environment (SCOPE) 6.1 Description 6.1 Description Page 1 Unless otherwise specified herein, general regulations contained in Part A, Sections 1 through 4 and Part E, Sections 1 and 2 apply in addition to the regulations contained in this

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

PI Server - 19 enclosures

PI Server - 19 enclosures PI Server - 19 The PI server enclosure range has been designed to complement our original PI Data enclosure and to accommodate the requirement of a cost effective server cabinet solution. This product

More information

DATACOM CABINETS SOLUTION GUIDE

DATACOM CABINETS SOLUTION GUIDE DATACOM CABINETS SOLUTION GUIDE designed to be better. LEGRAND S CABINET OFFERING Legrand cabinets are designed with cable management, airflow management and effortless installation to meet all network

More information

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications

More information

Table of Contents. 1 Introduction. 2 Reliability Predictions for Electronic Equipment. 3 Steady State Failure Rate Prediction for Devices

Table of Contents. 1 Introduction. 2 Reliability Predictions for Electronic Equipment. 3 Steady State Failure Rate Prediction for Devices Reliability Prediction Procedure for Electronic Equipment SR-332 Table of Contents Table of Contents 1 Introduction 1.1 Purpose and Scope.................................. 1 1 1.2 Changes........................................

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3

More information

EMC VMAX3 Family Site Planning Guide

EMC VMAX3 Family Site Planning Guide EMC VMAX3 Family Site Planning Guide VMAX 100K, VMAX 200K, VMAX 400K, with HYPERMAX OS REVISION 8.2 Copyright 2014-2018 Dell Inc. or its subsidiaries. All rights reserved. Published April 2018 Dell believes

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation

More information

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting. UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

RZ2 BioAmp Processor. Operator s Manual

RZ2 BioAmp Processor. Operator s Manual RZ2 BioAmp Processor Operator s Manual RZ2 BioAmp Processor Operator s Manual Copyright 2008-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

Installation Job Aid for Avaya Virtual Services Platform 7200 Series

Installation Job Aid for Avaya Virtual Services Platform 7200 Series Installation Job Aid for Avaya Virtual Services Platform 7200 Series Support Release 4.2.1 NN47228-301 Issue 01.02 January 2015 Go to the Avaya Support website at http://support.avaya.com for the most

More information

Introducing the Heat Wheel to the Data Center

Introducing the Heat Wheel to the Data Center Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique

More information

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor User Manual Rack Mount Display Monitor - 4K RMP-161-4K17 7U 17.3 inch Rack Mount Display Monitor Options : - DC 9~36V power input - Touchscreen - AR hardness glass Contents < Part. 1 > RMB-17W-4K 1.1 Package

More information

CVH Slot Media Converter Chassis Quick Installation Guide

CVH Slot Media Converter Chassis Quick Installation Guide CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site Preparation Guide 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered

More information

Specification. Chassis Specifications. Catalyst 9407R Switch Chassis Specifications

Specification. Chassis Specifications. Catalyst 9407R Switch Chassis Specifications Chassis Chassis, on page 1 Power Supply, on page 4 Chassis and Module Power and Heat Values, on page 8, on page 9 Catalyst 9407R Switch Chassis Table 1: Physical of the Chassis Dimensions (H x W x D) Rack

More information

Design and Installation Challenges: Aisle Containment Systems

Design and Installation Challenges: Aisle Containment Systems Design and Installation Challenges: Aisle Containment Systems 1 We all know the Benefits of Containment 1. Reduces Total Cost of Data Center Ownership 2. Eliminates hot spots 3. Supports higher heat and

More information

RZ5/RZ5D/RZ6 Processor. Operator s Manual

RZ5/RZ5D/RZ6 Processor. Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual Copyright 2010-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced

More information

PSW-002. Fiber Optic Polarization Switch. User Guide

PSW-002. Fiber Optic Polarization Switch. User Guide PSW-002 Fiber Optic Polarization Switch User Guide Version: 1.1 Date: June 30, 2015 General Photonics Corporation is located in Chino California. For more information visit the company's website at: www.generalphotonics.com

More information

PRODUCT FEATURES AND ADVANTAGES

PRODUCT FEATURES AND ADVANTAGES Flatpack2 24/1800 HE 24VDC Rectifier/Converter Modules The combination of innovative design, efficiency and reliability makes the Flatpack2 HE stand out. With efficiency up to 96.2%, the losses have been

More information

HP Integrity NonStop NS-Series Site Preparation Guide

HP Integrity NonStop NS-Series Site Preparation Guide HP Integrity NonStop NS-Series Site Preparation Guide Abstract This manual provides the physical, electrical, and environmental specifications for use by HP professional service personnel for site preparation,

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6) INT 492 : Selected Topic in IT II (Data Center Design) 3(3-0-6) การออกแบบระบบศ นย สารสนเทศ Overview The American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Technical Committee

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Test Report S

Test Report S Sunkom Pty Ltd FDX card s A101, A102, A104 and A108 Laboratory Details All tests were performed at : Comtest Laboratories Pty. Ltd. Unit 1 / 570 City Road South Melbourne Victoria 3205 Australia Telephone

More information

Power Systems. Site preparation and physical planning IBM

Power Systems. Site preparation and physical planning IBM Power Systems Site preparation and physical planning IBM Power Systems Site preparation and physical planning IBM Note Before using this information and the product it supports, read the information in

More information

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC July 2014 Robert Konnik. Nuclear Facilities Preview

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC July 2014 Robert Konnik. Nuclear Facilities Preview IEEE 383 Standard for Qualifying Electric Cables and Splices for NPEC July 2014 Robert Konnik Nuclear Facilities Preview IEEE 383 Background This standard provides guidance for developing a program to

More information

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc. USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-145 2018A-0119 Power Over Fiber SYSTEM INSTALLATI INFORMATI Description Our patented Power Over Fiber (PoF) system provides

More information

DeltaV Electronic Marshalling for Migrations

DeltaV Electronic Marshalling for Migrations DeltaV Distributed Control System Product Data Sheet DeltaV Electronic Marshalling for Migrations I/O anywhere you need it Single channel granularity Replaces legacy I/O in place Fully redundant architecture

More information

AT&T Switched Ethernet Service SM

AT&T Switched Ethernet Service SM Site Preparation Guide AT&T Switched Ethernet Service SM December 2016 2016 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

ATR012-HEX-3U. 1/2 ATR Chassis, Sealed w/heat Exchange KEY FEATURES

ATR012-HEX-3U. 1/2 ATR Chassis, Sealed w/heat Exchange KEY FEATURES ATR012-HEX-3U KEY FEATURES Rugged MIL 1/2 ATR enclosure for 3U boards Sealed conduction cooled enclosure with 4 heat exchangers + fan guards 5 slots at 1.0 pitch or 6 slots at 0.85 pitch 215mm H x 163mm

More information

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? A Network Power Management White Paper Who Needs Remote Power Management for Power Distribution,

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information