BICSI NxtGEN & Global Data Center Standards Update

Size: px
Start display at page:

Download "BICSI NxtGEN & Global Data Center Standards Update"

Transcription

1 BICSI NxtGEN & Global Data Center Standards Update Bob Faber, RCDD/NTS Siemon Global Accounts Manager Chair NEMA High Performance Wire & Cable Chair BICSI Standards Committee Vice Chair BICSI TI&M Committee Member TIA TR42 sub-committees Member SIA and NECA

2 BICSI NxtGEN NOW acquire specialties without RCDD 2 yrs ITS experience required Pass ITS fundamentals exam Pass specialty exam (NTS, OSP, WD, ESS) RCDD is now tougher to acquire 5 yrs ITS experience required Pass ITS fundamentals exam Pass RCDD exam Master RCDD, RCDD or RITP?

3 Education & Management Experience RITP ITS Core Exam ITS Training Requirements Master RCDD Review Board Master RCDD Application RCDD ITS Core Exam No add l Add l specialty or technician 3+ yrs add l experience Experience Equiv 3+ yrs add l experience Specialty or Experience Equiv 2 yrs ITS INDUSTRY Experience 2 yrs ITS DESIGN Experience ITS Fundamentals Exam

4

5 Technical Writing Committees Technical Information and Methods TDMM NDRM OSP WDRM ESS A/V Codes National Electrical Code Standards ANSI-accredited ANSI/NECA/BICSI ANSI/BICSI ANSI/NECA/BICSI ANSI/BICSI Healthcare Electronic Safety & Security

6 Global Data Center Standards 1. EN "Information Technology - Generic Cabling Systems - Part 5: Data Centres" 2. ISO/IEC FCD 24764: "Information Technology - Generic Cabling for Data Centre Premises 3. ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" ANSI/TIA "Data Center Coaxial Cabling Specifications and Application Distances 4. ANSI/BICSI-002 "Data Center Design Standard and Recommended Practices"

7 CENELEC EN ISO/IEC CD Category 6/Class E minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Copper & fiber trunks NOT addressed by this Standard Category 6 A /Class E A minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Informative Annex: Copper & fiber trunks addressed by this Standard

8 CENELEC EN OM2 minimum Fiber classes OM2 & OM3 OS1 & OS2 Fiber connectors standardized IEC or CENELEC ISO/IEC CD OM1 minimum 1. SM LC angled ENI 2. If 1 or 2 MM fiber, ENI 3. If 1 or 2 MM fiber, then EO 4. If multifiber, then MPO (Array) EO 1. IEC Part 7

9 Three cabling subsystems: 1. network access cabling 2. main distribution cabling 3. zone distribution cabling ISO/IEC CD & EN

10 ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" 1. Data Center Design Overview 2. Data Center Cabling Infrastructure 3. Data Center Telecommunications Spaces and Related Topologies 4. Data Center Cabling Systems 5. Data Center Cabling Pathways 6. Data Center Redundancy

11 ANSI/BICSI-002 "Data Center Design Standard & Recommended Practices" 1. Design Process 2. Space Planning 3. Redundancy 4. Site Selection 5. Architectural 6. Structural 7. Electrical 8. Mechanical 9. Fire Protection 10.Security 11.Building Automation 12.Access Providers 13.Telecom Spaces 14.Cabinets & Racks 15.Cabling Pathways 16.Cabling Systems 17.Cabling Field Testing 18.Telecom Administration 19.Information Technology 20.Commissioning 21.Maintenance

12 ANSI/TIA-942 Category 5e minimum for all subsystems Category 6 Recommended Copper & fiber trunks NOT addressed ANSI/BICSI-002 Category 6 minimum for all subsystems Category 6 A /Class E A Recommended Copper & fiber trunks are addressed by this Standard

13 ANSI/TIA-942 OM1 minimum OM3 Recommended Fiber connectors NOT specified ANSI/BICSI-002 OM2 minimum OM3 Recommended OM4 May be added Fiber connectors NOT specified

14 ANSI/TIA-942 & ANSI/BICSI-002 UPS up to 100 kva Permitted in computer room Larger should be located in a separate room Ceiling Height 2.6 m minimum clear height 450 mm clearance to water sprinkler heads Cable Tray Clearance 20 mm between top of tray & bottom of access floor tile Lighting 500 lux minimum Doors 1 m wide minimum 2.13 m high minimum Floor Loading 7.2 kpa minimum 12 kpa recommended Operational Parameters 20 o C to 25 o C temperature 40% to 55% humidity

15 CENELEC EN ISO/IEC FCD ANSI/TIA- 942 ANSI/BICSI- 002 Balanced Cabling Minimum (Recommended) Category 6 Class E Category6 A Class E A Category 5e (Category 6) Category 6 (Category 6 A ) Balanced Cabling Trunks Recognized NO YES NO YES Optical Fiber Cabling Minimum (Recommended) Optical Fiber Cabling Trunks Recognized OM2 or OM3 OM1 OM1 OM2 (OM3) OS1 or OS2 OS1 OS1 OM1 NO YES NO YES Optical Fiber Cabling Connectivity YES LC & ARRAY NOT SPECIFIED NOT SPECIFIED

16 Thank You Questions Encouraged

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic

More information

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications

More information

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Industry Standards in ICT Enabled Projects Reading and Applying the Fine Print Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland

More information

Application Note. Data Center Standards and Layouts

Application Note. Data Center Standards and Layouts Application Note Data Center Standards and Layouts 1. Data Center Standards In earlier times, a room in which one or more servers, a telephone system and active network components were located was often

More information

Welcome. BICSI And BICSI Standards, An Overview. Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director

Welcome. BICSI And BICSI Standards, An Overview. Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director Welcome BICSI And BICSI Standards, An Overview July 12 th 2007 Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director Greg Sherry, Qualitas Ltd 1976 - Started in the IT industry Various roles

More information

(Data Center Networks & Cloud Computing Security)

(Data Center Networks & Cloud Computing Security) BPSDC (Data Center Networks & Cloud Computing Security) Lecture 3 Data Center Standars Service Level Agreement 2 Building a Data Center is just a Start What is Service Level Agreement (SLA)? An official

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications

More information

ANSI/BICSI , Information Transport Systems Design Standard for K-12 Educational Institutions

ANSI/BICSI , Information Transport Systems Design Standard for K-12 Educational Institutions ANSI/BICSI-001-2009, Information Transport Systems Design Standard for K-12 Educational Institutions Terry W. Hochbein RCDD/NTS/OSP ATSR Architects/Engineers Forward PURPOSE This Standard specifies minimum

More information

CODES, STANDARDS AND PUBLICATIONS UPDATE

CODES, STANDARDS AND PUBLICATIONS UPDATE CODES, STANDARDS AND PUBLICATIONS UPDATE June 2014 Bob Hertling Supervising Communications Engineer RCDD, OSP RI Telecommunications Systems Contractor License #4848 PARSONS Member and Vice-Chair, BICSI

More information

Cabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari

Cabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari Cabling for Data Centres Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari Data Center Definition is a facility used to house computer systems and associated components, such as telecommunications

More information

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only 1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda

More information

Technical Planning for Moving Into a Colocation Data Center

Technical Planning for Moving Into a Colocation Data Center Technical Planning for Moving Into a Colocation Data Center Jonathan Jew - J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Secretary TIA TR-4 Telecommunications Cabling Systems Chair TIA

More information

Cabling a Data Center to TIA-942 Standard

Cabling a Data Center to TIA-942 Standard Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center

More information

CODES, STANDARDS AND PUBLICATIONS UPDATE March 2015

CODES, STANDARDS AND PUBLICATIONS UPDATE March 2015 CODES, STANDARDS AND PUBLICATIONS UPDATE March 2015 Bob Hertling Supervising Communications Engineer RCDD, OSP RI Telecommunications Systems Contractor License #4848 PARSONS Rail and Transit Systems Division

More information

Atras Network Communications

Atras Network Communications Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry

More information

DATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005

DATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005 DATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005 Mike Gilmore Managing Director, e-ready Building Convenor CENELEC TC215 WG1 Mike Gilmore Standards Activities Member JTC1 SC25 WG3: Generic

More information

AVANI Riverside Bangkok Hotel DAY 2 Garies Chong, RCDD, DCDC BICSI Southeast Asia District Chair M.D. of EMS Wiring Systems

AVANI Riverside Bangkok Hotel DAY 2 Garies Chong, RCDD, DCDC BICSI Southeast Asia District Chair M.D. of EMS Wiring Systems WELCOME BICSI Southeast Asia Thailand Conference 2017 (23 rd to 24 th November 2017) AVANI Riverside Bangkok Hotel DAY 2 Garies Chong, RCDD, DCDC BICSI Southeast Asia District Chair M.D. of EMS Wiring

More information

Industry Standards Activity Overview

Industry Standards Activity Overview Industry Standards Activity Overview Most Recent Plenary Meeting: June 12-16, 2017 in Quebec City, QC, CAN Updated: July 7, 2017 TR-42.1 Commercial Building Cabling: TIA TSB-185 Environmental Classification

More information

History of Standards

History of Standards History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures

More information

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents

More information

November 2010 IEEE 802.3

November 2010 IEEE 802.3 TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Vice Chair, TIA TR-42.7 November, 2010 Dallas, TX 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org TR-42:

More information

Copper Cabling Standards

Copper Cabling Standards Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals

More information

Introduction to Key Principles of Telecommunications Cabling

Introduction to Key Principles of Telecommunications Cabling Introduction to Key Principles of Telecommunications Cabling Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of

More information

IoT and Intelligent Building Challenges in ICT

IoT and Intelligent Building Challenges in ICT IoT and Intelligent Building Challenges in ICT Carol E. Oliver, RCDD, ESS Training and Contractor Manager LegrandNorth America Data Communications Division Yesterday Today History Repeats Itself... Yesterday...

More information

CERTIFICATION PLUS SM

CERTIFICATION PLUS SM CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation

More information

Telecommunications Structured Cabling Systems

Telecommunications Structured Cabling Systems Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Charleston, WV Rick Foster RCDD,TLT Communications Infrastructure Group April 20, 2006 Maurice Zetena Fiber Connect Standards TIA-942 NFPA-70 Article 645

More information

November 2013 IEEE 802.3

November 2013 IEEE 802.3 TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Telecommunications Cabling Systems Engineering Committee November, 2013 Dallas, TX 1 Introduction to TIA Telecommunications Industry

More information

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect How to Decide on Optical Fibre Termination Options Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect Termination Choices Optical Fiber Cabling in Data Center Options available Traditional

More information

Developing Standards for the Global Smart City & IoT Infrastructure Industry & Advancements in BICSI Training Programs for Aspiring ICT ACE & PMs

Developing Standards for the Global Smart City & IoT Infrastructure Industry & Advancements in BICSI Training Programs for Aspiring ICT ACE & PMs Developing Standards for the Global Smart City & IoT Infrastructure Industry & Advancements in BICSI Training Programs for Aspiring ICT ACE & PMs Paul Weintraub, RCDD, ESS, RTPM, TECH, CAE Vice President

More information

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS SECTION 27 11 19 COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section specifies the products and installation of communications termination blocks and patch panels

More information

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC :: Module Title Duration : Course CTDC : Certified TIA-942 Design Consultant : 3 days Course Description Data centres are at the core of many organisations. Downtime of the data centre could lead to major

More information

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the

More information

DATA CENTER CABLING DESIGN FUNDAMENTALS

DATA CENTER CABLING DESIGN FUNDAMENTALS White Paper DATA CENTER CABLING DESIGN FUNDAMENTALS Telecommunications Cabling Infrastructure Requirements according the Availability Classes I-IV of Introduction With the completion by end of Q1 2016,

More information

PANGEN SYSTEM WARRANTY. Warranty Guide

PANGEN SYSTEM WARRANTY. Warranty Guide PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &

More information

Technical Planning for Moving Into a Colocation Data Center

Technical Planning for Moving Into a Colocation Data Center Technical Planning for Moving Into a Colocation Data Center Jonathan Jew J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Secretary TIA TR-4 Telecommunications Cabling Systems Chair TIA TR-4.6

More information

Peter Sharp RCDD IBI Group

Peter Sharp RCDD IBI Group Peter Sharp RCDD IBI Group Who am I? Presenter Credentials Electrical Engineering Consultant Specialties in communications, electronics and computer sciences, In practice for more than 40 years Member

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant Is Cable Balancing Efficient i Enough for EMI Mitigation in Data Centers? Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant What are You going to Learn? What are the potential sources

More information

FTTE Revisited for New Technologies

FTTE Revisited for New Technologies FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern

More information

ABOUT ANIXTER UNIVERSITY

ABOUT ANIXTER UNIVERSITY Q4 2014 1 2 ABOUT ANIXTER UNIVERSITY Anixter University TM is the educational initiative of Anixter, a leading global supplier of communications and security products, electrical and electronic wire and

More information

Data Center Network Infrastructure

Data Center Network Infrastructure Data Center Network Infrastructure COPPER CAT 6 А, 7, 7 А, 8 Pre-Terminated Copper SOLUTIONS FIBER OPTIC Cables Category 6 A, 7, 7 A, 8.2 Cable Assemblies MTP/MPO Systems Copper Connectors Category 6 A,

More information

The Riser as a Contract Document. Peter Sharp, RCDD

The Riser as a Contract Document. Peter Sharp, RCDD The Riser as a Contract Document Peter Sharp, RCDD IBI Group 1 1 Who am I? Presenter Credentials Electrical Engineer Specialties in communications, electronics and computer sciences, In practice for 40

More information

SPECIFICATION STANDARD

SPECIFICATION STANDARD PART 1: GENERAL 1.01 SCOPE OF WORK SPECIFICATION STANDARD A. Work covered by this Section shall consist of furnishing labor, equipment, supplies, materials, and testing unless otherwise specified, and

More information

Michael A. Collins, RCDD, CCDA, NCE BICSI President Elect

Michael A. Collins, RCDD, CCDA, NCE BICSI President Elect BICSI Around the World Michael A. Collins, RCDD, CCDA, NCE BICSI President Elect Discussion What is BICSI? Global Presence Products & Services Credentials Training i Publications & Standards Events Key

More information

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional

More information

BICSI Northeast Regional Meeting June 17, Storrs CT. Considerations in Data Center Design. Thomas McNamara, RCDD

BICSI Northeast Regional Meeting June 17, Storrs CT. Considerations in Data Center Design. Thomas McNamara, RCDD BICSI Northeast Regional Meeting June 17, Storrs CT Considerations in Data Center Design Thomas McNamara, RCDD AGENDA Purpose is to allow the ITS professional to be aware of the issues and therefore pose

More information

ANSI/BICSI Data Center Design and Implementation Best Practices

ANSI/BICSI Data Center Design and Implementation Best Practices ANSI/BICSI 002-2014 Data Center Design and Implementation Best Practices Risk, Reliability & Availability Selecting a Data Center Design Class Bob Camerino RCDD DCDC CT Vice Chair BICSI Mainland Europe

More information

Design of the Physical Layer

Design of the Physical Layer Design of the Physical Layer Critical Choices for Today's Data Centres The Siemon Company: The partner of choice for your Global Data Centers Alberto Zucchinali RCDD Senior Technical Manager EMEA DC Solutions

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

Siemon Interconnect Solutions

Siemon Interconnect Solutions Siemon Interconnect Solutions W W W. S I E M O N. C O M / S I S technology at work for you DESIGN ENGINEERING Our Product Development Engineers and R&D Lab combine state of the art tools and capabilities

More information

Implementation considerations for cabling supporting remote powering

Implementation considerations for cabling supporting remote powering Implementation considerations for cabling supporting remote powering Table of contents Background...3 Advantages of remote powering using communications cabling...4 CommScope implementation considerations

More information

Structured Cabling Design for Large IT/Service Provider Data Centres. Liang Dong Yuan, Technical Sales manager, CDCE

Structured Cabling Design for Large IT/Service Provider Data Centres. Liang Dong Yuan, Technical Sales manager, CDCE Structured Cabling Design for Large IT/Service Provider Data Centres Liang Dong Yuan, Technical Sales manager, CDCE Structured Cabling Design for Large IT/Service Provider DCs Outline Section Industry

More information

Data Center Practices the Good, the Bad, & the Ugly

Data Center Practices the Good, the Bad, & the Ugly Data Center Practices the Good, the Bad, & the Ugly Image by Thiago Rodrigues Santos Jonathan Jew - J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Chair TIA TR-42.6 Telecom Administration

More information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017. Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations

More information

LAN Standards, News & Trends Update 2017 June 15, 2017

LAN Standards, News & Trends Update 2017 June 15, 2017 LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE

More information

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008 LAN Standards, News & Trends Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008 October 16, 2008 Objectives Review the recent events and activities of the TIA TR-42 Subcommittees Review

More information

PRODUCT DATA SHEET FLEX MODULE PDS wirewerks.com T F

PRODUCT DATA SHEET FLEX MODULE PDS wirewerks.com T F PRODUT DATA SHEET FLEX MODULE wirewerks.com T 1 888 993-4237 F 1 888 893-4237 DESRIPTION The NextSTEP FLEX Module is a ready-to-use, plug-and-play 12/24F MPO-MPO factory terminated cable assembly with

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Fiber in Data Centers What s Next? Srinivasan B, RCDD

Fiber in Data Centers What s Next? Srinivasan B, RCDD Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:

More information

THE INTERCONNECTED NETWORK

THE INTERCONNECTED NETWORK THE INTERCONNECTED NETWORK The Interconnected Network The number of applications / Services on a network increases from year to year. New applications are permanently in preparation. Server and Server

More information

HUBER+SUHNER DCCT Training

HUBER+SUHNER DCCT Training HUBER+SUHNER DCCT Training DCCT training The following topics are covered throughout the 2 course: Fiber optic fundamentals This is an optional section of the training which covers the basics about fiber

More information

Telecommunication Cabling Standards to address IoT and power delivery. 5 October

Telecommunication Cabling Standards to address IoT and power delivery. 5 October Telecommunication Cabling Standards to address IoT and power delivery 1 5 October 2018 www.vti.net.au In a nut shell Out for comment NOW AS/NZS 11801.1 (General requirements) AS 11801.2 (Office) AS 11801.3

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 15018 First edition 2004-06 Information technology Generic cabling for homes ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may

More information

Copper Riser And Intrabuilding Cabling

Copper Riser And Intrabuilding Cabling Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD ISO/IEC 11801-3 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 3: Industrial premises INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200

More information

This work is licensed under a Creative Commons Attribution 4.0 International License.

This work is licensed under a Creative Commons Attribution 4.0 International License. Revision, Licence & Use Revision History Date Description 05 Oct 2017 1.0 This work is licensed under a Creative Commons Attribution 4.0 International License. Checklist Use Information It has been defined

More information

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix Director of Business Technology Development Day Welcome Agenda Introduction CPR and Standards update Lunch Residential

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix CEP - Construction Products Director of regulations Business Development and the Impact on Cabling Standards CPD

More information

Classroom WiFi Network Infrastructure Plan

Classroom WiFi Network Infrastructure Plan Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to

More information

Fiber To The Office (FTTO) For Future-Proofed, Energy-Efficient and Economical Premise Cabling

Fiber To The Office (FTTO) For Future-Proofed, Energy-Efficient and Economical Premise Cabling Fiber To The Office (FTTO) For Future-Proofed, Energy-Efficient and Economical Premise Cabling Kandasamy Ganesan, RCDD, DCDC, TECH, CT Topnet Distribution FZCO Dubai, United Arab Emirates Agenda Modern

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB s Agreement Description for Central Office and POI Co-location 1 Interpretation 1.1 The Central Office and POI Co-location described in this Description will be available from the date

More information

Distributed ConvergeIT Systems. Lee Funnell EMEA Technical Manager

Distributed ConvergeIT Systems. Lee Funnell EMEA Technical Manager Distributed ConvergeIT Systems Lee Funnell EMEA Technical Manager Introduction Lee Funnell CTP, CDCDP EMEA Technical Manager British Standards Institute - Premises Cabling Experts Panel Data Centre Alliance

More information

FMT4S. High Density Connectivity Solution

FMT4S. High Density Connectivity Solution FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.

More information

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

Conflicts in Data Center Fiber Structured Cabling Standards

Conflicts in Data Center Fiber Structured Cabling Standards Conflicts in Data Center Fiber Structured Cabling Standards By Dave Fredricks, CABLExpress Data Center Infrastructure Architect Various telecommunications and data center (DC)-specific standards are commonly

More information

MOLEX PREMISE NETWORKS

MOLEX PREMISE NETWORKS MOLEX PREMISE NETWORKS Training Catalog Version 2.2 Bringing Advanced Physical Layer Lifecycle Management to Enterprises Worldwide Copper Fiber Wireless Advanced Physical Layer Management Advanced Physical

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6) INT 492 : Selected Topic in IT II (Data Center Design) 3(3-0-6) การออกแบบระบบศ นย สารสนเทศ Overview The American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Technical Committee

More information

CommercialNetworking: Training

CommercialNetworking: Training 17.1 Table of Contents CommercialNetworking: Training 17 Commercial Networking Training Page No. Overview: 17.2 / Course Number 17.3 17.6 Intro to Belden Belden IBDN 305 17.3 Project Management Belden

More information

Communication

Communication 27 00 00 Communication 1.01 Scope of Standard A. These guidelines identify and define Texas State University requirements and policies for designing and installing telecommunications infrastructure and

More information

PN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003

PN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003 0 NOTICE: PN--00 Telecommunications Infrastructure Standard for Data Centers Draft.0 July, 00 0 This contribution has been prepared to assist the TR- Standards Committee. It is offered to the Committee

More information

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture Issue Document Status Date: Prepared: Checked: 6 Cat 6 U/UTP, Optical Fibre and MER/SER Guidelines 29/03/2018

More information

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution 1 2 Agenda 1. Wirewerks introduction 2. Wirewerks products overview Data Center: Next Step TM Confidential Information Wirewerks

More information

Los Angeles Community College District Design Standards

Los Angeles Community College District Design Standards LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure

More information

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines Design Guidelines Issue 2 August 2010 Contents 1.0 Overview 3 2.0 Power Separation 4 3.0 Bonding and Grounding 4 4.0 Administration and Labeling 5 5.0 General Cable Guidelines 5 6.0 Bundling and Alien

More information

ANSI/BICSI Data Center Design and Implementation Best Practices

ANSI/BICSI Data Center Design and Implementation Best Practices ANSI/BICSI 002-2014 Data Center Design and Implementation Best Practices Risk, Reliability & Availability Selecting a Data Center Design Class Bob Camerino RCDD DCDC CT Secretary BICSI Mainland Europe

More information

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering

More information

Cabling Designer s Guide to Education

Cabling Designer s Guide to Education Cabling Designer s Guide to Education Published: December 1999 Important Note This is a living document created for cabling designers community. Please feel free to send your suggestions and additions

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled. 27 05 53 Identification (Labeling) for Communications Systems (Revision date: 3/6/13) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are part

More information

Checklist for building an edge data center

Checklist for building an edge data center Checklist for building an edge data center Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of

More information

Data center cabling design fundamentals

Data center cabling design fundamentals White paper Data center cabling design fundamentals Telecommunications cabling infrastructure requirements according the availability classes I-IV of EN 50600-2-4 www.commscope.com 1 Introduction With

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

PoE Lighting: Unleashing IoT and Opportunity in the ICT Industry

PoE Lighting: Unleashing IoT and Opportunity in the ICT Industry PoE Lighting: Unleashing IoT and Opportunity in the ICT Industry Bob Allan, MBA, LEED GA Global Business Development Manager Intelligent Buildings and Strategic Alliances @ballan32 There s a Revolution

More information

Infrastructure Challenges and Solutions for IoT and Intelligent Building Integration

Infrastructure Challenges and Solutions for IoT and Intelligent Building Integration Infrastructure Challenges and Solutions for IoT and Intelligent Building Integration Carol Everett Oliver, RCDD, ESS, Legrand North America Farukh Aslam, CEO, Sinclair Holdings LLC Yesterday History Repeats

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD ISO/IEC 11801-4 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 4: Single-tenant homes INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200

More information