BICSI NxtGEN & Global Data Center Standards Update
|
|
- Elvin Conley
- 6 years ago
- Views:
Transcription
1 BICSI NxtGEN & Global Data Center Standards Update Bob Faber, RCDD/NTS Siemon Global Accounts Manager Chair NEMA High Performance Wire & Cable Chair BICSI Standards Committee Vice Chair BICSI TI&M Committee Member TIA TR42 sub-committees Member SIA and NECA
2 BICSI NxtGEN NOW acquire specialties without RCDD 2 yrs ITS experience required Pass ITS fundamentals exam Pass specialty exam (NTS, OSP, WD, ESS) RCDD is now tougher to acquire 5 yrs ITS experience required Pass ITS fundamentals exam Pass RCDD exam Master RCDD, RCDD or RITP?
3 Education & Management Experience RITP ITS Core Exam ITS Training Requirements Master RCDD Review Board Master RCDD Application RCDD ITS Core Exam No add l Add l specialty or technician 3+ yrs add l experience Experience Equiv 3+ yrs add l experience Specialty or Experience Equiv 2 yrs ITS INDUSTRY Experience 2 yrs ITS DESIGN Experience ITS Fundamentals Exam
4
5 Technical Writing Committees Technical Information and Methods TDMM NDRM OSP WDRM ESS A/V Codes National Electrical Code Standards ANSI-accredited ANSI/NECA/BICSI ANSI/BICSI ANSI/NECA/BICSI ANSI/BICSI Healthcare Electronic Safety & Security
6 Global Data Center Standards 1. EN "Information Technology - Generic Cabling Systems - Part 5: Data Centres" 2. ISO/IEC FCD 24764: "Information Technology - Generic Cabling for Data Centre Premises 3. ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" ANSI/TIA "Data Center Coaxial Cabling Specifications and Application Distances 4. ANSI/BICSI-002 "Data Center Design Standard and Recommended Practices"
7 CENELEC EN ISO/IEC CD Category 6/Class E minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Copper & fiber trunks NOT addressed by this Standard Category 6 A /Class E A minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Informative Annex: Copper & fiber trunks addressed by this Standard
8 CENELEC EN OM2 minimum Fiber classes OM2 & OM3 OS1 & OS2 Fiber connectors standardized IEC or CENELEC ISO/IEC CD OM1 minimum 1. SM LC angled ENI 2. If 1 or 2 MM fiber, ENI 3. If 1 or 2 MM fiber, then EO 4. If multifiber, then MPO (Array) EO 1. IEC Part 7
9 Three cabling subsystems: 1. network access cabling 2. main distribution cabling 3. zone distribution cabling ISO/IEC CD & EN
10 ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" 1. Data Center Design Overview 2. Data Center Cabling Infrastructure 3. Data Center Telecommunications Spaces and Related Topologies 4. Data Center Cabling Systems 5. Data Center Cabling Pathways 6. Data Center Redundancy
11 ANSI/BICSI-002 "Data Center Design Standard & Recommended Practices" 1. Design Process 2. Space Planning 3. Redundancy 4. Site Selection 5. Architectural 6. Structural 7. Electrical 8. Mechanical 9. Fire Protection 10.Security 11.Building Automation 12.Access Providers 13.Telecom Spaces 14.Cabinets & Racks 15.Cabling Pathways 16.Cabling Systems 17.Cabling Field Testing 18.Telecom Administration 19.Information Technology 20.Commissioning 21.Maintenance
12 ANSI/TIA-942 Category 5e minimum for all subsystems Category 6 Recommended Copper & fiber trunks NOT addressed ANSI/BICSI-002 Category 6 minimum for all subsystems Category 6 A /Class E A Recommended Copper & fiber trunks are addressed by this Standard
13 ANSI/TIA-942 OM1 minimum OM3 Recommended Fiber connectors NOT specified ANSI/BICSI-002 OM2 minimum OM3 Recommended OM4 May be added Fiber connectors NOT specified
14 ANSI/TIA-942 & ANSI/BICSI-002 UPS up to 100 kva Permitted in computer room Larger should be located in a separate room Ceiling Height 2.6 m minimum clear height 450 mm clearance to water sprinkler heads Cable Tray Clearance 20 mm between top of tray & bottom of access floor tile Lighting 500 lux minimum Doors 1 m wide minimum 2.13 m high minimum Floor Loading 7.2 kpa minimum 12 kpa recommended Operational Parameters 20 o C to 25 o C temperature 40% to 55% humidity
15 CENELEC EN ISO/IEC FCD ANSI/TIA- 942 ANSI/BICSI- 002 Balanced Cabling Minimum (Recommended) Category 6 Class E Category6 A Class E A Category 5e (Category 6) Category 6 (Category 6 A ) Balanced Cabling Trunks Recognized NO YES NO YES Optical Fiber Cabling Minimum (Recommended) Optical Fiber Cabling Trunks Recognized OM2 or OM3 OM1 OM1 OM2 (OM3) OS1 or OS2 OS1 OS1 OM1 NO YES NO YES Optical Fiber Cabling Connectivity YES LC & ARRAY NOT SPECIFIED NOT SPECIFIED
16 Thank You Questions Encouraged
Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee
Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic
More informationOptimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit
Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications
More informationIndustry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"
Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland
More informationApplication Note. Data Center Standards and Layouts
Application Note Data Center Standards and Layouts 1. Data Center Standards In earlier times, a room in which one or more servers, a telephone system and active network components were located was often
More informationWelcome. BICSI And BICSI Standards, An Overview. Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director
Welcome BICSI And BICSI Standards, An Overview July 12 th 2007 Presented by: Greg Sherry RCDD/NTS/WD BICSI European Region Director Greg Sherry, Qualitas Ltd 1976 - Started in the IT industry Various roles
More information(Data Center Networks & Cloud Computing Security)
BPSDC (Data Center Networks & Cloud Computing Security) Lecture 3 Data Center Standars Service Level Agreement 2 Building a Data Center is just a Start What is Service Level Agreement (SLA)? An official
More informationData Center Design and the ANSI/TIA-942 Standard
Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications
More informationANSI/BICSI , Information Transport Systems Design Standard for K-12 Educational Institutions
ANSI/BICSI-001-2009, Information Transport Systems Design Standard for K-12 Educational Institutions Terry W. Hochbein RCDD/NTS/OSP ATSR Architects/Engineers Forward PURPOSE This Standard specifies minimum
More informationCODES, STANDARDS AND PUBLICATIONS UPDATE
CODES, STANDARDS AND PUBLICATIONS UPDATE June 2014 Bob Hertling Supervising Communications Engineer RCDD, OSP RI Telecommunications Systems Contractor License #4848 PARSONS Member and Vice-Chair, BICSI
More informationCabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari
Cabling for Data Centres Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari Data Center Definition is a facility used to house computer systems and associated components, such as telecommunications
More informationCopper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only
1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda
More informationTechnical Planning for Moving Into a Colocation Data Center
Technical Planning for Moving Into a Colocation Data Center Jonathan Jew - J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Secretary TIA TR-4 Telecommunications Cabling Systems Chair TIA
More informationCabling a Data Center to TIA-942 Standard
Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center
More informationCODES, STANDARDS AND PUBLICATIONS UPDATE March 2015
CODES, STANDARDS AND PUBLICATIONS UPDATE March 2015 Bob Hertling Supervising Communications Engineer RCDD, OSP RI Telecommunications Systems Contractor License #4848 PARSONS Rail and Transit Systems Division
More informationAtras Network Communications
Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry
More informationDATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005
DATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005 Mike Gilmore Managing Director, e-ready Building Convenor CENELEC TC215 WG1 Mike Gilmore Standards Activities Member JTC1 SC25 WG3: Generic
More informationAVANI Riverside Bangkok Hotel DAY 2 Garies Chong, RCDD, DCDC BICSI Southeast Asia District Chair M.D. of EMS Wiring Systems
WELCOME BICSI Southeast Asia Thailand Conference 2017 (23 rd to 24 th November 2017) AVANI Riverside Bangkok Hotel DAY 2 Garies Chong, RCDD, DCDC BICSI Southeast Asia District Chair M.D. of EMS Wiring
More informationIndustry Standards Activity Overview
Industry Standards Activity Overview Most Recent Plenary Meeting: June 12-16, 2017 in Quebec City, QC, CAN Updated: July 7, 2017 TR-42.1 Commercial Building Cabling: TIA TSB-185 Environmental Classification
More informationHistory of Standards
History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationNovember 2010 IEEE 802.3
TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Vice Chair, TIA TR-42.7 November, 2010 Dallas, TX 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org TR-42:
More informationCopper Cabling Standards
Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals
More informationIntroduction to Key Principles of Telecommunications Cabling
Introduction to Key Principles of Telecommunications Cabling Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of
More informationIoT and Intelligent Building Challenges in ICT
IoT and Intelligent Building Challenges in ICT Carol E. Oliver, RCDD, ESS Training and Contractor Manager LegrandNorth America Data Communications Division Yesterday Today History Repeats Itself... Yesterday...
More informationCERTIFICATION PLUS SM
CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation
More informationTelecommunications Structured Cabling Systems
Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major
More informationData Center Design and the ANSI/TIA-942 Standard
Data Center Design and the BICSI Regional Meeting Charleston, WV Rick Foster RCDD,TLT Communications Infrastructure Group April 20, 2006 Maurice Zetena Fiber Connect Standards TIA-942 NFPA-70 Article 645
More informationNovember 2013 IEEE 802.3
TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Telecommunications Cabling Systems Engineering Committee November, 2013 Dallas, TX 1 Introduction to TIA Telecommunications Industry
More informationHow to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect
How to Decide on Optical Fibre Termination Options Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect Termination Choices Optical Fiber Cabling in Data Center Options available Traditional
More informationDeveloping Standards for the Global Smart City & IoT Infrastructure Industry & Advancements in BICSI Training Programs for Aspiring ICT ACE & PMs
Developing Standards for the Global Smart City & IoT Infrastructure Industry & Advancements in BICSI Training Programs for Aspiring ICT ACE & PMs Paul Weintraub, RCDD, ESS, RTPM, TECH, CAE Vice President
More informationThe University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS
SECTION 27 11 19 COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section specifies the products and installation of communications termination blocks and patch panels
More informationCourse Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::
Module Title Duration : Course CTDC : Certified TIA-942 Design Consultant : 3 days Course Description Data centres are at the core of many organisations. Downtime of the data centre could lead to major
More informationSPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING
PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the
More informationDATA CENTER CABLING DESIGN FUNDAMENTALS
White Paper DATA CENTER CABLING DESIGN FUNDAMENTALS Telecommunications Cabling Infrastructure Requirements according the Availability Classes I-IV of Introduction With the completion by end of Q1 2016,
More informationPANGEN SYSTEM WARRANTY. Warranty Guide
PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &
More informationTechnical Planning for Moving Into a Colocation Data Center
Technical Planning for Moving Into a Colocation Data Center Jonathan Jew J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Secretary TIA TR-4 Telecommunications Cabling Systems Chair TIA TR-4.6
More informationPeter Sharp RCDD IBI Group
Peter Sharp RCDD IBI Group Who am I? Presenter Credentials Electrical Engineering Consultant Specialties in communications, electronics and computer sciences, In practice for more than 40 years Member
More informationSiemon PON Fiber Cabling Solutions
Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility
More informationDr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant
Is Cable Balancing Efficient i Enough for EMI Mitigation in Data Centers? Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant What are You going to Learn? What are the potential sources
More informationFTTE Revisited for New Technologies
FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern
More informationABOUT ANIXTER UNIVERSITY
Q4 2014 1 2 ABOUT ANIXTER UNIVERSITY Anixter University TM is the educational initiative of Anixter, a leading global supplier of communications and security products, electrical and electronic wire and
More informationData Center Network Infrastructure
Data Center Network Infrastructure COPPER CAT 6 А, 7, 7 А, 8 Pre-Terminated Copper SOLUTIONS FIBER OPTIC Cables Category 6 A, 7, 7 A, 8.2 Cable Assemblies MTP/MPO Systems Copper Connectors Category 6 A,
More informationThe Riser as a Contract Document. Peter Sharp, RCDD
The Riser as a Contract Document Peter Sharp, RCDD IBI Group 1 1 Who am I? Presenter Credentials Electrical Engineer Specialties in communications, electronics and computer sciences, In practice for 40
More informationSPECIFICATION STANDARD
PART 1: GENERAL 1.01 SCOPE OF WORK SPECIFICATION STANDARD A. Work covered by this Section shall consist of furnishing labor, equipment, supplies, materials, and testing unless otherwise specified, and
More informationMichael A. Collins, RCDD, CCDA, NCE BICSI President Elect
BICSI Around the World Michael A. Collins, RCDD, CCDA, NCE BICSI President Elect Discussion What is BICSI? Global Presence Products & Services Credentials Training i Publications & Standards Events Key
More informationJamey Calloway, RCDD Product Management Specialist Optical Cable Corporation
Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional
More informationBICSI Northeast Regional Meeting June 17, Storrs CT. Considerations in Data Center Design. Thomas McNamara, RCDD
BICSI Northeast Regional Meeting June 17, Storrs CT Considerations in Data Center Design Thomas McNamara, RCDD AGENDA Purpose is to allow the ITS professional to be aware of the issues and therefore pose
More informationANSI/BICSI Data Center Design and Implementation Best Practices
ANSI/BICSI 002-2014 Data Center Design and Implementation Best Practices Risk, Reliability & Availability Selecting a Data Center Design Class Bob Camerino RCDD DCDC CT Vice Chair BICSI Mainland Europe
More informationDesign of the Physical Layer
Design of the Physical Layer Critical Choices for Today's Data Centres The Siemon Company: The partner of choice for your Global Data Centers Alberto Zucchinali RCDD Senior Technical Manager EMEA DC Solutions
More informationf) Telecommunications Equipment Rooms
SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification
More informationSiemon Interconnect Solutions
Siemon Interconnect Solutions W W W. S I E M O N. C O M / S I S technology at work for you DESIGN ENGINEERING Our Product Development Engineers and R&D Lab combine state of the art tools and capabilities
More informationImplementation considerations for cabling supporting remote powering
Implementation considerations for cabling supporting remote powering Table of contents Background...3 Advantages of remote powering using communications cabling...4 CommScope implementation considerations
More informationStructured Cabling Design for Large IT/Service Provider Data Centres. Liang Dong Yuan, Technical Sales manager, CDCE
Structured Cabling Design for Large IT/Service Provider Data Centres Liang Dong Yuan, Technical Sales manager, CDCE Structured Cabling Design for Large IT/Service Provider DCs Outline Section Industry
More informationData Center Practices the Good, the Bad, & the Ugly
Data Center Practices the Good, the Bad, & the Ugly Image by Thiago Rodrigues Santos Jonathan Jew - J&M Consultants, Inc. Co-chair BICSI Data Center Subcommittee Chair TIA TR-42.6 Telecom Administration
More informationv2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.
Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations
More informationLAN Standards, News & Trends Update 2017 June 15, 2017
LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE
More informationLAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008
LAN Standards, News & Trends Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008 October 16, 2008 Objectives Review the recent events and activities of the TIA TR-42 Subcommittees Review
More informationPRODUCT DATA SHEET FLEX MODULE PDS wirewerks.com T F
PRODUT DATA SHEET FLEX MODULE wirewerks.com T 1 888 993-4237 F 1 888 893-4237 DESRIPTION The NextSTEP FLEX Module is a ready-to-use, plug-and-play 12/24F MPO-MPO factory terminated cable assembly with
More informationTarleton State University. Specifications
Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication
More informationFiber in Data Centers What s Next? Srinivasan B, RCDD
Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:
More informationTHE INTERCONNECTED NETWORK
THE INTERCONNECTED NETWORK The Interconnected Network The number of applications / Services on a network increases from year to year. New applications are permanently in preparation. Server and Server
More informationHUBER+SUHNER DCCT Training
HUBER+SUHNER DCCT Training DCCT training The following topics are covered throughout the 2 course: Fiber optic fundamentals This is an optional section of the training which covers the basics about fiber
More informationTelecommunication Cabling Standards to address IoT and power delivery. 5 October
Telecommunication Cabling Standards to address IoT and power delivery 1 5 October 2018 www.vti.net.au In a nut shell Out for comment NOW AS/NZS 11801.1 (General requirements) AS 11801.2 (Office) AS 11801.3
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 15018 First edition 2004-06 Information technology Generic cabling for homes ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may
More informationCopper Riser And Intrabuilding Cabling
Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable
More informationCommunications. UNM IT/Telecommunications Guide Specification Communications
The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary
More informationINTERNATIONAL STANDARD
ISO/IEC 11801-3 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 3: Industrial premises INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200
More informationThis work is licensed under a Creative Commons Attribution 4.0 International License.
Revision, Licence & Use Revision History Date Description 05 Oct 2017 1.0 This work is licensed under a Creative Commons Attribution 4.0 International License. Checklist Use Information It has been defined
More informationIEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3
IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org
More informationConnectix Cabling Systems
Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix Director of Business Technology Development Day Welcome Agenda Introduction CPR and Standards update Lunch Residential
More informationConnectix Cabling Systems
Connectix Cabling Systems Cabling Standards and CPR Update Jason Holroyd CNID Connectix CEP - Construction Products Director of regulations Business Development and the Impact on Cabling Standards CPD
More informationClassroom WiFi Network Infrastructure Plan
Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to
More informationFiber To The Office (FTTO) For Future-Proofed, Energy-Efficient and Economical Premise Cabling
Fiber To The Office (FTTO) For Future-Proofed, Energy-Efficient and Economical Premise Cabling Kandasamy Ganesan, RCDD, DCDC, TECH, CT Topnet Distribution FZCO Dubai, United Arab Emirates Agenda Modern
More informationUltrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service
Ultrafast Fibre UFB s Agreement Description for Central Office and POI Co-location 1 Interpretation 1.1 The Central Office and POI Co-location described in this Description will be available from the date
More informationDistributed ConvergeIT Systems. Lee Funnell EMEA Technical Manager
Distributed ConvergeIT Systems Lee Funnell EMEA Technical Manager Introduction Lee Funnell CTP, CDCDP EMEA Technical Manager British Standards Institute - Premises Cabling Experts Panel Data Centre Alliance
More informationFMT4S. High Density Connectivity Solution
FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.
More informationChorus UFB Services Agreement Service Description for Central Office and POI Co-location Service
Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description
More informationConflicts in Data Center Fiber Structured Cabling Standards
Conflicts in Data Center Fiber Structured Cabling Standards By Dave Fredricks, CABLExpress Data Center Infrastructure Architect Various telecommunications and data center (DC)-specific standards are commonly
More informationMOLEX PREMISE NETWORKS
MOLEX PREMISE NETWORKS Training Catalog Version 2.2 Bringing Advanced Physical Layer Lifecycle Management to Enterprises Worldwide Copper Fiber Wireless Advanced Physical Layer Management Advanced Physical
More informationNZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling
Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation
More informationINT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)
INT 492 : Selected Topic in IT II (Data Center Design) 3(3-0-6) การออกแบบระบบศ นย สารสนเทศ Overview The American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Technical Committee
More informationCommercialNetworking: Training
17.1 Table of Contents CommercialNetworking: Training 17 Commercial Networking Training Page No. Overview: 17.2 / Course Number 17.3 17.6 Intro to Belden Belden IBDN 305 17.3 Project Management Belden
More informationCommunication
27 00 00 Communication 1.01 Scope of Standard A. These guidelines identify and define Texas State University requirements and policies for designing and installing telecommunications infrastructure and
More informationPN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003
0 NOTICE: PN--00 Telecommunications Infrastructure Standard for Data Centers Draft.0 July, 00 0 This contribution has been prepared to assist the TR- Standards Committee. It is offered to the Committee
More informationConnectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture
Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture Issue Document Status Date: Prepared: Checked: 6 Cat 6 U/UTP, Optical Fibre and MER/SER Guidelines 29/03/2018
More informationWirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution
Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution 1 2 Agenda 1. Wirewerks introduction 2. Wirewerks products overview Data Center: Next Step TM Confidential Information Wirewerks
More informationLos Angeles Community College District Design Standards
LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure
More informationSYSTIMAX GigaSPEED Xpress Solution Design Guidelines
Design Guidelines Issue 2 August 2010 Contents 1.0 Overview 3 2.0 Power Separation 4 3.0 Bonding and Grounding 4 4.0 Administration and Labeling 5 5.0 General Cable Guidelines 5 6.0 Bundling and Alien
More informationANSI/BICSI Data Center Design and Implementation Best Practices
ANSI/BICSI 002-2014 Data Center Design and Implementation Best Practices Risk, Reliability & Availability Selecting a Data Center Design Class Bob Camerino RCDD DCDC CT Secretary BICSI Mainland Europe
More informationIXcellerate Moscow One Datacentre - Phase 1 & 2 Overview
Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering
More informationCabling Designer s Guide to Education
Cabling Designer s Guide to Education Published: December 1999 Important Note This is a living document created for cabling designers community. Please feel free to send your suggestions and additions
More informationANSI/TIA/EIA-568-B Cabling Standard
73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before
More informationUltrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service
Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description
More informationE. Numbering and Labeling Pathway components. In general, pathway components are not labeled.
27 05 53 Identification (Labeling) for Communications Systems (Revision date: 3/6/13) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are part
More informationChecklist for building an edge data center
Checklist for building an edge data center Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of
More informationData center cabling design fundamentals
White paper Data center cabling design fundamentals Telecommunications cabling infrastructure requirements according the availability classes I-IV of EN 50600-2-4 www.commscope.com 1 Introduction With
More informationAnticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards
Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper
More informationPoE Lighting: Unleashing IoT and Opportunity in the ICT Industry
PoE Lighting: Unleashing IoT and Opportunity in the ICT Industry Bob Allan, MBA, LEED GA Global Business Development Manager Intelligent Buildings and Strategic Alliances @ballan32 There s a Revolution
More informationInfrastructure Challenges and Solutions for IoT and Intelligent Building Integration
Infrastructure Challenges and Solutions for IoT and Intelligent Building Integration Carol Everett Oliver, RCDD, ESS, Legrand North America Farukh Aslam, CEO, Sinclair Holdings LLC Yesterday History Repeats
More informationINTERNATIONAL STANDARD
ISO/IEC 11801-4 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 4: Single-tenant homes INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200
More information