Validus DC Systems. DC Power Distribution Solutions Serving: Mission Critical Applications Next Generation Data Centers Green IT Infrastucture

Size: px
Start display at page:

Download "Validus DC Systems. DC Power Distribution Solutions Serving: Mission Critical Applications Next Generation Data Centers Green IT Infrastucture"

Transcription

1 Validus DC Systems DC Power Distribution Solutions Serving: Mission Critical Applications Next Generation Data Centers Green IT Infrastucture Copyright Validus DC Systems, LLC

2 AC vs. DC: A Quick Tutorial Scalable DC Power Distribution Solutions for Mission Critical Facilities, Buildings and Utilities Copyright Validus DC Systems, LLC

3 AC vs. DC: An Overview Alternating Current: An alternating current (AC) is an electrical current whose magnitude and direction vary cyclically, as opposed to direct current, whose direction remains constant. The usual waveform of an AC power circuit is a sine wave, as this results in the most efficient transmission of energy. Used generically, AC refers to the form in which electricity is delivered to businesses and residences. Direct Current: Direct current (DC or continuous current ) is the constant flow of electric charge. This is typically in a conductor such as a wire, but can also be through semiconductors, insulators, or even through a vacuum as in electron or ion beams. In direct current, the electric charges flow in the same direction, distinguishing it from alternating current. Most electronic circuits require a DC power supply. Today, most electricity is transported at AC format. But since DC power is needed to run most electronics, AC power must be converted into DC power at some point. Thomas Edison originally promoted DC for electrical power distribution, considering it a safer, more reliable option than AC power. Copyright Validus DC Systems, LLC Company Overview - Dec

4 AC vs. DC: An Overview, Continued DC power is commonly used today (i.e., subway systems, and the telecommunications industry) because of its reliability and efficiency It is well understood that DC power is a more stable approach to power distribution. AC requires sine wave and grid synchronization whereas, DC electrical charges flow in the same direction at a constant. This quality allows DC systems to not only offer greater stability, but also to enables seamless integration of renewable power sources (which all produce energy in the DC format). Additionally, AC systems require a series of step up and step down power conversions that result in energy losses (energy released in the form of heat), which then must subsequently be cooled. This power and cooling challenge has become an equally serious issue in data centers. DC requires fewer power transformations, thus fewer losses, and less demand on infrastructure cooling. Copyright Validus DC Systems, LLC Company Overview - Dec

5 Why DC Makes Sense for the Data Center First of all the semiconductors used in computing and communications equipment runs on DC. Power supplies and POL (Point of Load) converters transform AC into the right power required by the target silicon. By distributing DC power you will: Reduce the number of conversions and energy losses before the load Increase system reliability by removing conversion equipment Simplify the system architecture Gain a higher utilization of existing floor space Enable a direct seamless integration infrastructure for renewable energy sources (i.e., Solar PV, Solar SC, Wind Turbine, etc.) DC power distribution and Validus system optimization enables: Increased system efficiency, monitoring and maintainability Modular system enhancements including both power and cooling Tailored reduction in TCO for current and next generation data centers Risk mitigation through effective co-existence with legacy AC systems Copyright Validus DC Systems, LLC Company Overview - Dec

6 Validus DC Systems: Who We Are Scaleable DC Power Distribution Solutions for Mission Critical Facilities, Buildings and Utilities Copyright Validus DC Systems, LLC

7 Company Overview Headquartered in Brookfield, Connecticut Established in 2002 Capitalized by private equity - Lead investor is Oak Hill Venture Partners $10 million series A funding round closed in December 2007 Leadership team with deep experience in IT facilities management, mission-critical application development, electrical engineering, systems integration, and power systems maintenance Rudy Kraus, CEO Ron Croce, COO Frank J. Catapano, Vice President of Technical Services Technology developed in partnership with Dr. Marcel Gaudreau, former head of Massachusetts Institute of Technology s Plasma Science and Fusion Center. Copyright Validus DC Systems, LLC Company Overview - Dec

8 What Validus Does Validus offers a fully integrated, Direct Current, mission critical power infrastructure solution that is available today Validus patented, end-to-end, DC power distribution system is safe, affordable and scalable, enabling end users to efficiently distribute -575 VDC power to the load and scale it to -48 VDC where appropriate In data center applications, Validus powers high-density -48 VDC IT equipment while reducing overall energy consumption and both increasing available floor space and overall system reliability The Validus solution includes: Large scale central rectification systems Central plant power conversion systems DC distribution equipment Back up power sources and field support The Validus technology is already proven in military applications Copyright Validus DC Systems, LLC Company Overview - Dec

9 AC vs. Validus DC Power Paths (potential configuration) Copyright Validus DC Systems, LLC

10 Benefits of the Validus DC Systems Solution REDUCES ENABLES PROVIDES Energy consumption by up to 40% (compared to legacy systems) by reducing conversions, rectifications, transformations and duplications Copper distribution costs by 16 20% Cooling requirements in data centers typically 1 cooling watt to 1 processing watt Use of DC servers that are more reliable and energyefficient (no PFC or AC silver box) Use of various fuel cells, batteries, flywheels, and renewable energy sources (i.e., Solar / Wind) in multiple locations Use of DC converters that have a more flat efficiency curve at 20 40% loads than AC devices at similar loads More reliability through fewer conversions / less equipment and effective use of O-ring diodes Energy storage Redundant power supplies Scalable feeds to LED lighting Processing equipment Motors Cooling equipment AGGREGATES & OPTIMIZES SCALEABLE CENTRAL POWER SUPPLIES Fewer parts count, greater efficiency, reliability and maintainability Allows for higher voltage AC to be rectified closer to the load 15kV to rectifiers Can build modular power and cooling systems Copyright Validus DC Systems, LLC Company Overview - Dec

11 A Typical AC Data Center Floor Plan Conventional data center layout with 100 server racks housing 25 servers in each rack, based on Dell SC 1425 Servers are typical Dell and/or Sun Systems Watts per server = 302; watts per rack = 7550 Cooling consists of nine, 30 ton CRAC units. One CRAC unit is redundant Total data center power requirements = 755kw Total data center cooling requirement = 214 tons Total data center watts per square foot = 234 Total data center square footage = 2,777 2,777 square foot data center Scale: 1/8 = 1-0 Source: Dell Copyright Validus DC Systems, LLC Company Overview - Dec

12 A Typical DC Data Center Power converters PCU systems and Rackable DC configuration layout with 82 servers in each rack and a total of 30 server racks DC racks with built-in hot aisle exhaust Watts per server = 175; watts per rack = 9000 Cooling consists of six 30 ton CRAC units. One CRAC is redundant Total data center power requirements = 410kw Total data center cooling requirement = 116 tons Total data center watts per square foot = 276 Total data center square footage = 1,400 (including power modules) 1,400 square foot data center Scale: 1/8 = 1-0 Source: Rackable Copyright Validus DC Systems, LLC Company Overview - Dec

13 Markets and Vertical Opportunities Data Centers Telecommunications Lighting Applications (i.e. LED) Utility Distribution Systems utilizing DC Motors, Drives, Cooling Systems Renewable Energy Generation Plants Copyright Validus DC Systems, LLC Company Overview - Dec

14 Validus DC Systems Product Portfolio Scaleable DC Power Distribution Solutions for Mission Critical Facilities, Buildings and Utilities Copyright Validus DC Systems, LLC

15 The Power Converter Unit (PCU 120) The Power Converter Unit, or PCU 120, is the enabling component in Validus DC power system The PCU s main job is to step down high power (up to 120KW) to safe, usable DC power at the voltage level required at the point of use (i.e., server or rack) The PCU typically consists of up to 4 integrated Power Converter Modules (PCMs) Technical specifications: kw in a 19 Rack 30kW modular drawers Flat efficiency curve above 15% loading N+1 90 KW of load -575 VDC input, -54 VDC output Hot swappable power supply modules Dual feed capable PLC controls Custom controls and monitoring available Remote monitoring and control TUV approved to UL and IEC/ECN and FCC Part 15 A standards Output to PDM-055, bus duct or cable tray Copyright Validus DC Systems, LLC Company Overview - Dec

16 The Power Converter Module (PCM 030 / 30kW DC-DC) The PCM is the highly efficient power conversion engine of the PCU, and delivers a precise regulated output to service any load demand (up to 30KW) The PCMs can be hot swapped during usage, meaning they can be handled safely, maintained, and taken offline even when they are in an operational mode Technical specifications: -575 VDC Input -54 VDC Output Compact design Will operate independently from other power supplies Highly efficient under dynamic and low loading Hot swappable Copyright Validus DC Systems, LLC Company Overview - Dec

17 The Power Quality Module (PQM) The Validus DC Systems PQM (Power Quality Module) is the interface to the utility power connected to the facility The job of the PQM is to convert 150KW to 2.5MW (at 50-60Hz) of AC from the utility, to the high voltage DC distributed to the balance of the Validus DC System architecture The PQM also maintains system stability despite inconsistencies in line power and ensures a high level of reliability through its inherent fault tolerant design Technical specifications: Mission Critical Rectifier Plant with Enhanced Features for Monitoring, Pre-Alarming, Paralleling and Operation 150 KW to 2,500 KW 50 or 60 Hz. Units Available Full Input Voltage Range from 208 VAC to 34,000 VAC Indoor or Outdoor Units Available Copyright Validus DC Systems, LLC Company Overview - Dec

18 The Power Distribution Module (PDM 550) The Validus DC Systems PDM 550 is a switchboard that controls the power traffic across multiple system inputs and the DC distribution components This component interfaces with the Power Quality Module, stored energy devices (i.e., batteries), battery charger components, and provides load distribution throughout Technical specifications: Rated 800 to 6,000 Amp, 600 VDC Integrates One or More Inputs, PCU Output Feeders and Stored Energy System Components Can Support N or 2N Distribution Architectures Can Accept Multiple DC Input Sources via a Simple Diode Can be Equipped with a Variety of Alarming and Monitoring Solutions Copyright Validus DC Systems, LLC Company Overview - Dec

19 The Power Distribution Module-Fused Distribution Bay (PDM 054) The PDM 054 is a free standing, fused, control module that distributes the output of a PCU 120 The PDM 054 also supports 2N system (redundant power design) load configurations and can manage the output of 2 Power Converter Units Technical specifications: -60 VDC Fused Distribution Bay Rated 2,400 Amps, Single or Dual Feed Mounted Adjacent to PCU 120 Uses TPL Type Fuses (100 to 800 Amp) Can Support Up to 30 Output Feeders to Server Racks Circuit Breakers Available Can be Equipped with a Variety of Alarming and Monitoring Solutions Copyright Validus DC Systems, LLC Company Overview - Dec

20 The Battery Charging System (PQX) The Validus DC Systems PQX in an air-cooled, AC powered, stand-alone battery charging system designed work seamlessly with the Validus DC Systems line of PDM 550 switchboards and standalone battery systems The PQX includes an interactive LCD display, RS232/485 Modbus RTU communication interface, Form C contacts for summary and high ripple alarms, and automatic restart after a high voltage shutdown event Technical specifications: Stand Alone Battery Charger Designed to Interface with PDM 550 and PBS System Custom Designed to VDCS Requirements 50 Amp Rated Equipped with RS-485 Interface for Remote Monitoring Copyright Validus DC Systems, LLC Company Overview - Dec

21 The Power Battery System (PBS) The The Validus DC Systems PBS is a stand alone battery cabinet system that seamlessly integrates the Validus line of PDM 550 switchboards and provides reserve power to further backup to the system. The standard PBS system is developed to support predefined battery backup run time and to leverage a ten year maintenance free battery in a standalone or parallel configuration. All standard PBS systems are provided in battery cabinets equipped with a DC disconnect and the required system interface components to interconnect each cabinet to the PDM 550 switchboard. Alternate battery solutions, including wet cell, rack mounted, modular and lithium ion units are available upon request. Technical specifications: Sealed Maintenance Free Battery Cabinet with a Full Range of System Run Times Flywheel solutions Wet Cell Solutions Available Can be Provided with a Variety of Industry Standard Monitoring and Alarming Solutions Copyright Validus DC Systems, LLC Company Overview - Dec

22 For more information please visit our Web Site located at: Or contact us at: Validus DC Systems, LLC 50 Pocono Road Brookfield, CT Copyright Validus DC Systems, LLC

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications DC POWER OVERVIEW BROCHURE NETSURE APPLICATIONS yradio Base Station / Microwave Site ywireless & Wireline Access

More information

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

3300 kw, Tier 3, Chilled Water, 70,000 ft 2 [Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied

More information

PRODUCTS AND SERVICES. At a glance

PRODUCTS AND SERVICES. At a glance PRODUCTS AND SERVICES At a glance ELTEK DEUTSCHLAND GMBH Eltek Deutschland is a full-range provider of protected power supplies for the telecom, renewable and OEM power industries and industrial applications.

More information

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology Liebert APM from 30 to 300 kw The Compact Row Based UPS With FlexPower Technology LIEBERT APM from 30 to 300 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

A. Advanced Features. Configurable High Power Solution

A. Advanced Features. Configurable High Power Solution Sorensen HPX Series High Power Extensible Programmable DC Series 36 kw - 240 kw 10-1000 V 45-6000 A Advanced Features High Power Density: Up to 150KW in a single bay rack-mount cabinet. Up to 240KW in

More information

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance

More information

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Socomec Netys PR RT U P S TOWER / RACK MOUNT Socomec Netys PR RT Ideal solution for protecting small servers, networking devices and peripherals. Assures service continuity to critical applications. Designed for professional applications: the sinevawe

More information

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology APM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology T M LIEBERT APM UPS Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can

More information

SMARTONLINE E3 UPS SYSTEMS

SMARTONLINE E3 UPS SYSTEMS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,

More information

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS POWERING TECHNOLOGY Reliably powering your business. Solving your power needs. DC POWER SYSTEMS P O W E R I N G T E C H N O L O G Y UNIPOWER Systems today incorporates products from the former Power-One

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

02 Why Does My IT Infrastructure Need a UPS?

02 Why Does My IT Infrastructure Need a UPS? UPS Buyer s Guide TABLE OF CONTENTS 01 What is a UPS? 02 Why Does My IT Infrastructure Need a UPS? 03 Common Features of UPS Systems ENERGY STORAGE SYSTEMS BATTERIES POWER PROTECTION MONITORING SOLUTIONS

More information

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG. Alternative Energy Series and Field of Use LVD Series Low-Voltage Disconnect (LVD) stops battery damage due to over discharge by disconnecting the battery at an adjustable voltage. DCDC Series Regulated

More information

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; 4 0 0 V D C p o w e r f e e d s o l u t i o n Juha Klemola / HW Architect / Nokia Introduction to the challenge Datacenter

More information

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application. DC Power Solutions Overview DC Power Solutions for EVERY Network Application. DC Power Solutions for Every Network Application Eaton recognizes the challenges that are unique to different customers applications.

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM Liebert NXr Series 30kVA to 160kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

Converged Power Solutions. Data center power reinvented

Converged Power Solutions. Data center power reinvented Converged Power Solutions Data center power reinvented always on anywhere anytime With Eltek s Converged Power Solutions, the next generation power solution for data centers is here. It offers unmatched

More information

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW PowerWAVE 9250DPA (50 250 N+1 kva/kw) Parallelable up to 1.5 MVA/MW True modular UPS for medium power applications in critical, high-density computing environments such as small to medium-sized data centres,

More information

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Highly Efficient Power Protection for High Density Computing Applications

Highly Efficient Power Protection for High Density Computing Applications Highly Efficient Power Protection for High Density Computing Applications IB Power and Cooling Symposium Lennart Jonsson Eaton Corporation 2007 Eaton Corporation. All rights reserved. Impact of High Density

More information

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines

More information

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers The right-sized UPS for demanding business-critical applications The Schneider Electric Symmetra PX 96/160

More information

Pros and Cons of Various DC Distribution Architectures

Pros and Cons of Various DC Distribution Architectures Pros and Cons of Various DC Distribution Architectures Source: Solar Powered Datacenter by Google Randy Malik Power Technology And Qualification IBM RTP Raleigh NC Rick Fishbune Power Technology And Qualification

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Revision 1 Executive Summary A new approach to power distribution for high density

More information

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines

More information

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2 [Reference esign 62] 9.6 MW, Traditional IT and OC-compatible, Indirect Air Economizer, 16970 m 2 ESIGN OVERVIEW ata Center IT Capacity 9.6 MW Target Availability Tier III with 2N power distribution and

More information

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS NEXT GENERATION TECHNOLOGY Toshiba International Corporation provides a full range of Uninterruptible Power Systems (UPS) for datacenter/, commercial/ retail,

More information

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft. [Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL

More information

Est FlexiPower Ultra UPS FPX Ultra kVA

Est FlexiPower Ultra UPS FPX Ultra kVA Est.1968 FlexiPower Ultra UPS FPX Ultra 500 1000kVA Prepared by Thycon Industrial Pty Ltd. The Thycon FlexiPower Ultra boasts the lowest cost of ownership of any UPS system by offering energy efficiency,

More information

5.2 MW, Pod-based build, Chilled Water, ft 2

5.2 MW, Pod-based build, Chilled Water, ft 2 [Reference Design 65] 5.2 MW, Pod-based build, hilled Water, 85000 ft 2 DESIGN OVERVIEW Data enter apacity 5.2 MW Target Availability Tier III with 2N power distribution and less-redundant generator configuration

More information

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM Liebert NX Series 30kVA to 200kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across

More information

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline

More information

Redundant Power Supplies. Keep Machines Up When Power Goes Down

Redundant Power Supplies. Keep Machines Up When Power Goes Down Redundant Power Supplies Keep Machines Up When Power Goes Down When your operation is critical, you need power you can count on. Redundant Power Systems are ideal for any equipment where the highest attainable

More information

CPS VS UPS FOR POWERING DATA CENTERS

CPS VS UPS FOR POWERING DATA CENTERS CPS VS UPS FOR POWERING DATA CENTERS HOW THE ADVANTAGES OF A NO BREAK CONVERGED POWER SYSTEM (CPS) PROVIDED BETTER POWER RELIABILITY, SYSTEM AVAILABILITY AND REDUCED COSTS OVER A UNINTERRUPTABLE POWER

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable to 20 kw Modular, scalable, high-efficiency power protection for data centers The Symmetra TM PX 20 kw is a world-class, high-efficiency, ENERGY STAR qualified power protection system designed

More information

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the electrical,

More information

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application MUST900 Modular UPS 30-300 kva modular UPS - up to 900 Datacenter & servers Internet centers Local Area Networks (LAN) Telecommunication devices Emergency application Smart Energy Solutions HOT SWAP 0.9

More information

Mid-Sized Data Center UPS Solutions Overview

Mid-Sized Data Center UPS Solutions Overview Mid-Sized Data Center UPS Solutions Overview 2008 2008 Eaton Eaton Corporation. Corporation. All All rights rights reserved. reserved. Mid-Range System Concerns IT / ENGINEERS / BUYERS Cooling Designs

More information

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America MODEL NUMBER: SU80KTV Highlights 80,000 VA (80kVA) tower UPS with 4 hot-swappable power

More information

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 kw to1500 kw N+1

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Zenith Series STS-3 Static Transfer Switches

Zenith Series STS-3 Static Transfer Switches GE Energy Connections Zenith Series STS-3 Static Transfer Switches 60Hz UL Version, 150-1600AMP Seamless Input Source Transfers for Sensitive Critical Loads. Touching all Areas of the Energy Industry GE

More information

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM Powering Change in the Data Center A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity are driving change in the power and

More information

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW PRODUCT BROCHURE Conceptpower DPA 120 208V UL Modular UPS 20kW 600kW 2 CONCEPTPOWER DPA 120 280V MODULAR UPS Today s data centers require continuous uptime. That target is why ABB s Conceptpower DPA 120

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

High Voltage Direct Current Power Solutions for Data Centers

High Voltage Direct Current Power Solutions for Data Centers High Voltage Direct Current Power Solutions for Data Centers Professor: Dr. Danny Silver Acadia University Student Name: Jim Nasium Published: April 10 th, 2011 1. Introduction As the demand on data centers

More information

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Description Tripp Lite's SU40K (40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line

More information

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA

More information

Current Trends in UPS Technology. Voltages

Current Trends in UPS Technology. Voltages Voltages 1 Voltages 3-ph, 4 W, 120/208V classification for small and mid range sizes 3-ph, 480V classification is typical in larger capacity UPS Systems 3-ph, 4 W, 230/400V becoming more widely used in

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW Product brochure Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW 2 Product brochure Conceptpower DPA 120 UL UPS Conceptpower DPA 120 The modular UPS for small and medium-sized data centers UPS

More information

380VDC Data Center Duke Energy Charlotte, NC

380VDC Data Center Duke Energy Charlotte, NC 380VDC Data Center Duke Energy Charlotte, NC Dennis P. Symanski EPRI - Senior Project Manager Silicon Valley Leadership Group 2011 Data Center Efficiency Summit 18NOV2011 IBM - San Jose, CA 380VDC Data

More information

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline

More information

POWER PROBLEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

POWER PROBLEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R POWER PROBLEMS Power Problems: > External causes (utility outages) > Internal causes (CB trip, inrush, bus failure) Power Problems: > Black-out, Brown -out, Sags, Swells, Surges, Transients, Waveform Distortion

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

Infinisolar V Hybrid-On Grid Inverter with Energy Storage Infinisolar V Hybrid-On Grid Inverter with Energy Storage Pure sine wave output Self-consumption and Feed-in to the grid Programmable supply priority for PV, Battery or Grid User-adjustable charging current

More information

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW Liebert APM The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative

More information

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications APM UPS 18kW - 90kW The Flexpower Technology for mission critical applications WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable

More information

Eaton DC Power Solutions

Eaton DC Power Solutions Eaton DC Power Solutions 19 sub-rack Modular 3U and 6U options Up to 6 rectifier modules Pre-configured software High power density (24/48V: 300/250A, 6U, 19 ) Multiple AC option (1Ø, 3Ø, 2Ø) Fast on-line

More information

AC Power For Business-Critical Continuity. Liebert NX. UPS For Small And Medium Business

AC Power For Business-Critical Continuity. Liebert NX.  UPS For Small And Medium Business AC Power For Business-Critical Continuity Liebert NX For Small And Medium Business Emerson Network Power Has A That Matches Your Growth Plans Changing data centers, rapid and unpredictable growth, plus

More information

24/48V Battery Bank Ah High Cycling Long Life

24/48V Battery Bank Ah High Cycling Long Life Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module

More information

Protected Power Supply for your Applications. Telecom Industrial Data Center

Protected Power Supply for your Applications. Telecom Industrial Data Center Protected Power Supply for your Applications Telecom Industrial Data Center The future is here. ELTEK Deutschland- Your partner for highly efficient power systems and services When it comes to power conversion

More information

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency

More information

Modular and Scalable Power Converters in the UPS Industry

Modular and Scalable Power Converters in the UPS Industry A-PDF Split DEMO : Purchase from www.a-pdf.com to remove the watermark Modular and Scalable Power Converters in the Industry Ian Wallace Eaton Corporation, Innovation Center 1 Eaton Overview Eaton Electric

More information

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW PRODUCT BROCHURE Conceptpower DPA 500 480V UL Modular UPS 100kW 3MW 2 C O N C E P T P O W E R D PA 5 0 0 4 8 0 V M O D U L A R U P S Today s data centers require continuous uptime. That target is why ABB

More information

Liebert NXC from 10 to 60kVA

Liebert NXC from 10 to 60kVA Liebert NXC from 10 to 60kVA We help make the future of our customers business possible. Emerson Network Power, a global company that leads by applying a unique combination of industry expertise, technology,

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

Cisco CRS 16-Slot Chassis Power Systems

Cisco CRS 16-Slot Chassis Power Systems This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power

More information

the Centric 300 An advanced modular UPS up to 1800kVA/kW

the Centric 300 An advanced modular UPS up to 1800kVA/kW the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has

More information

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Highlights 40,000 VA (40kVA) tower UPS with 2 hot-swappable power modules N+1 redundant

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Rail solutions. Energizing a sustainable rail industry

Rail solutions. Energizing a sustainable rail industry Rail solutions Energizing a sustainable rail industry At Eaton, we are helping many of the world s rail leaders build a more sustainable future. Eaton is a leading power management company, providing energy

More information

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016 BY H S W Karunaratne Assistant Director - Engineering Sri Lanka Standards Institution. 1 DEFINITIONS Ac module:

More information

aentron Energy System 1 to 900 Vdc

aentron Energy System 1 to 900 Vdc aentron Energy System 1 to 900 Vdc The aentron lithium-ion energy system enables the realisation of a modular and scalable lithium-ion battery solution. The management of large lithium-ion batteries systems

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Hitec QPS product range

Hitec QPS product range Hitec QPS product range Continuous Power Uninterrupted Power Quality Power Highest No-Break UPS Ratings Exceptional Power Density Modular Design Approach Best End-to-End Efficiency Optimized Availability

More information

The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power. Alex Emms Operations Director

The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power. Alex Emms Operations Director The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power Alex Emms Operations Director Less UPS Drivers More UPS Drivers UPS Datacentre Drivers/Trends Datacentres =

More information

XTREME POWER CONVERSION THE VALUE LEADER IN POWER PROTECTION

XTREME POWER CONVERSION THE VALUE LEADER IN POWER PROTECTION CONVERSION THE VALUE LEADER IN POWER PROTECTION Xtreme Power is a global manufacturer of power quality and data center solutions Xtreme Power manufactures UPS from 400VA to 40kVA Designs, engineers, and

More information

WIRELESS ENVIRONMENTAL MONITORS

WIRELESS ENVIRONMENTAL MONITORS Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless

More information

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution Liebert NXC 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution Regardless of your size, you can t afford for your critical business systems to go down and you can t waste time

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager Power+ Family Products 1 P+ Family Products: Seth Davis- Global Marketing Manager Power+ Family Product line Power+ 10-20KVA 19 2 Mega Power+ 3 Power+ Family Product line Have you ever asked yourself what

More information

2016 IEEE / MCPG meetings cycle,

2016 IEEE / MCPG meetings cycle, 2016 IEEE / MCPG meetings cycle, Kameel Andrawos Director, Power Systems Schneider Electric Nashville, TN UPS Topologies UPS Construction Modular construction Traditional with plug-in assemblies UPS Configuration

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

Est FlexiPower Maxi UPS FPX Maxi kVA

Est FlexiPower Maxi UPS FPX Maxi kVA Est.1968 FlexiPower Maxi UPS FPX Maxi 50 250kVA True modular UPS system for critical applications Designed and Published by Thycon. A UPS DESIGNED TO MEET THE NEEDS OF TODAY AND TOMORROW The FlexiPower

More information

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU6000RT3UHV 6000VA online 6U rack / tower UPS (3U Power Module + 3U Battery

More information

JUNXY Series DC Load Banks

JUNXY Series DC Load Banks JUNXY Series DC Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, AC & DC generator, rectifier, transformers, inverter etc working in good

More information

GE Zenith ZDEC Modular Paralleling Switchgear

GE Zenith ZDEC Modular Paralleling Switchgear GE Zenith ZDEC 2020 Modular Paralleling Switchgear ZDEC 2020 Has the Solution Healthcare and Critical Facilities Demand Generator Paralleling Systems that are Flexible design compatible with multiple brands

More information

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Description Tripp Lite's SU80KX (80kVA) SmartOnline Modular 3-Phase

More information