HPE Performance Optimized Datacenter (POD) Networking Guide

Size: px
Start display at page:

Download "HPE Performance Optimized Datacenter (POD) Networking Guide"

Transcription

1 HPE Performance Optimized Datacenter (POD) Networking Guide Abstract This document provides networking guidance for the various HPE PODs. Part Number: R November 2015 Edition: 4

2 Copyright 2011, 2015 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.

3 Contents Overview... 4 Networking introduction... 4 Network best practices... 4 Planning considerations... 4 Network hardware not requiring customization in the HPE POD rack... 5 Network hardware requiring customization in HPE POD infrastructure... 6 Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A)... 8 HPE network switchbox enclosure... 8 Cisco MDS 9500 multilayer director Cisco Catalyst 6500-E Other hardware considerations Cabling POD cable management POD 240a cable management POD 40c and POD 20c cable management Integrating additional IT at the customer site Network access Network entry Network demarcation Frequently asked questions Documentation feedback Contents 3

4 Overview Networking introduction This guide is a primer and does not cover all networking best practices for the PODs. The customer has responsibility for providing the airflow direction of the network devices that are intended to be installed, especially if the devices are customer-furnished equipment. This must be managed by the account team and the network solution architect. Devices that require hot aisle servicing or maintenance must be placed in racks that allow full rear access. This document includes hardware that is optimized for the HPE POD 240a, HPE POD 40c, and HPE POD 20c airflow cooling and hardware that will need special consideration. Network best practices The following best practices are established for all POD network configurations: Ensure that customer intent is finalized and documented. Assign a network specialist as early as possible (from the customer side) to create and finalize the POD network design and configuration to include point-to-point specification. Refer to this guide to understand which network devices require customization and, if possible, install network devices recommended by Hewlett Packard Enterprise. Use the network switch enclosure option, SKU AT053A, for those devices that utilize side-to-side air-flow cooling, and use side panels, SKU AT960A, as required. Understand the hardware size specifications of the equipment being placed inside the racks of the POD to ensure interference limitations are taken into consideration. Arrange to have the external telecom box sized according to the customer's requirement. Hewlett Packard Enterprise does not provide this box. Plan accordingly for high cable counts aggregating to core network racks. Planning considerations The POD can support various Tier x interconnects via an External Telecom Panel or direct termination at the rack level via patch panels. An External Telecom Panel enables each customer to adjust to fit their specific site requirements. The customer should plan to either install an External Telecom Panel as part of their site design, or plan another solution for demarcation in to the POD. In planning the correct solution, the customer must consider: What Telecom panel rating is required? What is the size of the Telecom panel (H x W x D)? Where is the entry point for the Telecom panel? Which hardware components are required for termination? What is the hardware placement within the Telecom panel? Overview 4

5 How many fiber/copper devices are being terminated? What are the length of service loops within the Telecom panel? Is hardware designed to be used only in racks? Is this single or multi-homed? Are the network specifications available? Are site and network drawings available? If you require Hewelett Packard Enterprise to provide an External Telecom Panel with termination hardware, specifications must be clearly identified by the customer to Hewelett Packard Enterprise, and will involve lead time and cost incremental to the basic solution. Network hardware not requiring customization in the HPE POD rack NOTE: For current information, see the appropriate product website. For more information, see the following: ProCurve 6600 Series HPE 5800AF Series HPE Series HPE S9508E-V Router HPE A6616 Router HPE 8808-V Router Arista 7048T, 7050 switches Cisco Nexus 2000 Series Fabric Extender o If the Cisco Nexus 2000 must be positioned with ports flush to the rear of the POD rack, custom mounting brackets will be required. Cisco Nexus 5000 Series Cisco Nexus 7010 Cisco 4948 E(-F) Cisco 6509-V-E Quanta LB4M QLogic Additional information: Several of these previously listed devices have the potential of supporting up to 864 ports, which can result in a large volume of cables, and must be placed in a rack that has full rear-door access to facilitate the maintenance or the replacement of hardware. The recessing of switches to be flush with the back of the rack will require the prevention of air flow recirculation to eliminate the mixing of hot aisle and IT section air. Overview 5

6 Network hardware requiring customization in HPE POD infrastructure CAUTION: The IT section and hot aisle air separation begins on the front side of the rack at the RETMA rails. Any hardware with air inlets on the side will intake hot aisle air and have the potential to overheat. Devices that work best inside the POD utilize a front-to-back airflow model. Any devices designed with side-to-side airflow need special consideration. The network solution architect of the account team should understand hardware air-flow requirements prior to requesting a formal legal quote from the respective order management team. The following network hardware does require a customized air-flow solution: HPE MSR30-xx series router Cisco 3700 series Cisco 3750-E The following figure shows the airflow for the 3750-E. Cisco 3750-X The following figure shows the airflow for the 3750-X, which includes air inlets on the port side and are not found in the 3750-E model. Cisco 4948 Cisco Catalyst 6500-E Overview 6

7 Cisco 3800 series router Cisco 2350 series switch Cisco MDS 9124 multilayer fabric switch Cisco 9500 series multilayer director F5 BIG IP 6800 series Digi CM Procurve 2600, 2900, 5400 Avocent Cyclades ACS48 Switches that are not itemized above must be evaluated by the POD network SA to determine if a customized solution is required. All applicable hardware and technical specifications for the devices must be provided to the POD network specialist in the initial engagement stage in order to mitigate last-minute customizations. All customizations impact price, schedule, and resources. NOTE: Some hardware components are labeled as having front-to-back airflow. However, the front of the component, as identified by the vendor, might need to be reoriented in order to prevent overheating and enable proper cooling, as the following image illustrates. Overview 7

8 Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A) HPE network switchbox enclosure Devices that are not optimized for front-to-back airflow require an Network Switchbox Enclosure Kit (SKU AT053A) which has been designed to alleviate overheating. The following figure is a diagram of the AT053A kit. During the design phase, the additional RU space required for the top and bottom of the enclosure must be considered. Both the base and the top of the enclosure use 1RU, which leaves 3RU open within the enclosure. Even though there are 4RU open spaces, an empty RU is required between devices for air flow and cable management. The following images show the side air flow. Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A) 8

9 AT053A Rack with two side to side air flow switches Item Component Description 1 Air baffle top The top of the air baffle that allows side air flow. 2 Air baffle bottom The bottom of the air baffle that allows side air flow. AT053A Rack with three side to side air flow switches Item Component Description 1 Air baffle top The top of the air baffle that allows side air flow. 2 Air baffle bottom The bottom of the air baffle that allows side air flow. For efficient airflow, maintain a minimum space of 1RU between devices when stacking more than two devices together. IMPORTANT: If installing a single 1RU switch in a Network Switch Enclosure, you must leave one empty RU either above or below the switch to allow for air circulation. Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A) 9

10 Devices that are installed in the Network Switch Enclosure and require more than 3RU of space will need additional side panels from the (Network Switch Enclosure Sidepanel Kit (SKU AT960A). The rack openings on the back side of the AT053A Network Switch Enclosure must be filled with blanking panels. Cisco MDS 9500 multilayer director This device requires 3RU minimum space below and above the chassis to provide air flow. The device also requires a Network Switchbox Enclosure Kit (SKU AT053A) as depicted in the previous illustration, as well as the Network Switch Enclosure Sidepanel Kit side panels (SKU AT960A) on the inlet side only. Do not install side panels on the exhaust side of the device. To enable adequate airflow along the top, bottom, and side of the air-inlet side of the chassis, the MDS 9500 must be placed on a support rail and secured to the rack with custom mounting brackets, allowing the chassis to be recessed in the rack. Care must be taken to also maintain hot and cold air-flow separation. The 9500 series switches have complex air flow and will require additional parts and customization. The account SA is responsible for engaging directly with the POD network SA for additional guidance. Rack-mount support brackets from Cisco are included with this device and are required for installation. These brackets are not removable. Power cables for this device must be secured at a level above the chassis to enable fan tray removal. All network cables must be secured to the side of the rack. Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A) 10

11 Cisco Catalyst 6500-E This device requires 2RU minimum space below and 3RU above the chassis. The device also requires a Network Switchbox Enclosure Kit (SKU AT053A) and an Network Switch Enclosure Side panel Kit (SKU AT960A). The Cisco Catalyst 6500-E does not require a side panel kit on the exhaust side of the chassis. To enable adequate airflow along the top, bottom, and side of the air-inlet side of the chassis, the 6500-E must be placed on a support rail and secured to the rack with custom mounting brackets, allowing the chassis to be recessed in the rack. Care must be taken to also maintain hot and cold air-flow separation. The 6500 series switches have complex air flow and will require additional parts and customization for successful operation. The account SA is responsible for engaging directly with the POD network SA for additional guidance. Other hardware considerations To maintain hot and cold air seperation while the TFT is in the open position, you must place TFT and KVM devices inside an Network Switchbox Enclosure Kit (SKU AT053A). NOTE: Each customer has individual site requirements, and requires a customized Statement of Work from Hewlett Packard Enterprise Technical Services. Addressing airflow with HPE Network Switchbox Enclosure Kit (SKU AT053A) 11

12 Cabling POD cable management The customer must create and finalize the POD network design and configuration to include point-to-point cabling specification prior to the receipt of the purchase order. The customer network solution architect will work with the Hewlett Packard Enterprise account team network solution architect to finalize the POD network strategy. The following figure illustrates the rack dimensions that must be considered. Item Component Description 1 RETMA rail 29-inches from the front to the back 2 Rack 35-inches from the front to the back POD 240a cable management The POD 240a utilizes a wire-tray basket system suspended above the racks and positioned towards the rear of the rack for cable management. Feature Specification Location Cable tray over rack aisle Cable tray connecting IT sections across the hot aisle Cable tray across the hot aisle connecting the IT sections Clearances Must maintain a minimum of 2 in between the top of the racks and the bottom of the cable tray Must maintain a minimum of 91.9 in between base of cable tray and the floor Dimensions of cable 16 in wide x 2 in deep x 10 ft long tray sections over racks Cabling 12

13 Feature Specification Quantity of cable tray sections over racks Dimensions of cable tray sections across the hot aisle Quantity of cable tray sections across the hot aisle connecting the IT sections Four per rack aisle Eight total per POD 240a 8 in wide x 2 in deep x 98 in long Three per POD 240a The following image illustrates the location of the cable tray in the hot aisle. The inset image illustrates how the cable tray hangs from the ceiling of the hot aisle. Top view shown POD 40c and POD 20c cable management For large quantities of cables in the hot aisle, order one of the following: POD 40c; SKU AT965A, POD 40ft Cable Cover Kit POD 20c; SKU AT966A, POD 20ft Cable Cover Kit Feature Specification Location Quantity of floor cable tray sections in hot aisle Dimensions of floor cable tray sections across the hot aisle Floor tray in hot aisle Six per POD 40c: 4 long, 2 short Three per POD 20c: 1 long, 2 short 9 in wide x 3.75 in deep Cabling 13

14 The following images illustrate the cable tray. Integrating additional IT at the customer site When installing additional hardware in the POD on location, follow these guidelines: Maintain hot and cold air separation within the racks. PDUs in the POD are not equipped with L6-20 connectors. POD 240a In the POD 240a, avoid rack placement for network switches in racks 1 and 22. Cabling 14

15 Top view shown POD 40c Item Component Description 1 Dock side The side of the POD 240a that provides direct access to IT section A, IT section B, and the hot aisle. 2 Truck/power side The side of the POD 240a that provides access to all main power components. In the POD 40c, avoid rack placement for network switches in racks 1, 2, 5, 6, 7, 11, 12, 16, 17, 18, 21 and 22. POD 40c G2 In the POD 40c G2, avoid rack placement for network switches in racks 4, 8, 12, 16, and 20. NOTE: In the following illustration, the racks that are shaded provide clear access to the back of the rack via the rear doors. Cabling 15

16 POD 20c In the POD 20c, avoid rack placement for network switches in racks 1, 5, 6, and 10. Cabling 16

17 Network access Network entry POD 240a The POD 240a has six network access points at the rear of the POD 240a above the cargo doors. NOTE: The connection portal location and configuration might look different, depending on the POD design. Rear cargo end view shown POD 40c and POD 20c The POD 40c and POD 20c have six network access penetrations in vertical alignment on the rear cargo door. Network access 17

18 Rear cargo end view shown NOTE: The cargo doors might look different, depending on the POD design. The POD 40c G2 also has six network access penetrations in vertical alignment on the water connect side of the POD. Water connection end view shown The POD 40c G2 also has a single network access penetration on the water connect side of the POD. Network access 18

19 Water connection end view shown Network demarcation Network configurations vary; therefore, the customer is responsible for installing external telecom panel access. The POD does not ship with an external telecom panel to serve as a demarcation point of entry into the POD. Therefore, customers must specify the appropriate external telecom panel. An external telecom panel is not required to extend network cables from outside the POD. A patch panel installed in a rack to distribute connectivity can serve as a demarcation point. However, if the customer decides to install an external telecom panel, the following figure shows the location of a panel. Network access 19

20 POD external telecom panel example The external telecom panel model can be applied to any POD version as long as the size, rating, cable count capacity, and mounting location requirements are met. Network access 20

21 Frequently asked questions 1. Can a customer use mounting ear brackets on the equipment in the racks in the POD? When installing through the front of the rack (IT section), yes. If equipment must be installed from the back of the rack (hot aisle), Hewlett Packard Enterprise recommends rail kits instead of mounting ear brackets for devices to be used in the racks. The customer must ensure that rail kits are available for the third-party equipment that is ordered from their respective vendor. Hewlett Packard Enterprise does not recommend using mounting ear brackets in the racks on devices installed from the back of the rack. 2. Is plenum-rated cable needed in the POD? Hewlett Packard Enterprise recommends that you confirm with local agencies to understand permit requirements. 3. How do I plan for network connectivity from the outside world in to the POD and what should I take into consideration? The POD can support various Tier X interconnects via an external telecom panel or direct termination at the rack level to patch panels. Since each customer requires a customized solution, the customer can normally procure and install an external telecom panel or patch panels for direct termination to fit the specific site requirements. The customer should plan to install an external telecom panel or direct termination as part of their site design for demarcation to the POD. In planning the correct solution, the customer must consider: o What is the telecom panel rating requirement? o What is the size of telecom panel (H x W x D)? o What is the entry point for the telecom panel? o What hardware components are required for termination? o What is the placement of hardware within telecom panel? o What are the fiber/copper quantities being terminated? o What are local codes for network cabling requirements (plenum, non-plenum, or LSZH rated)? o What are the lengths of the service loops required within the telecom panel? o Is the hardware being specified in the telecom panel designed to be used only in racks? o Is connectivity single or multi-homed? o Are network specifications available for the required hardware? o Are drawings available of the design? Frequently asked questions 21

22 Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page. Documentation feedback 22

HP D6000 Disk Enclosure Direct Connect Cabling Guide

HP D6000 Disk Enclosure Direct Connect Cabling Guide HP D6000 Disk Enclosure Direct Connect Cabling Guide Abstract This document provides cabling examples for when an HP D6000 Disk Enclosure is connected directly to a server. Part Number: 682251-001 September

More information

QuickSpecs. HP Rack G2 Series Overview

QuickSpecs. HP Rack G2 Series Overview Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

QuickSpecs. HPE G2 Enterprise Series Racks. Overview Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise

More information

QuickSpecs. HP Rack G2 Series. Overview

QuickSpecs. HP Rack G2 Series. Overview Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

QuickSpecs. Compaq Rack Accessories

QuickSpecs. Compaq Rack Accessories Compaq offers a wide variety of rack accessories that help you to configure Compaq Racks. For more information go to http://www.compaq.com/racks or http://www.compaq.com/rackoptions. Compaq Flat Panel

More information

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

QuickSpecs. HPE G2 Enterprise Series Racks. Overview Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise

More information

Aruba JL311A Cable Guard Installation Instructions

Aruba JL311A Cable Guard Installation Instructions Aruba JL3A Cable Guard Installation Instructions Abstract Use this guide to assist in the basic installation of the Aruba JL3A Cable Guard on select Aruba 8 port switches. *500-97* Part Number: 500-97

More information

QuickSpecs. HPE G2 Advanced Series Racks. Overview

QuickSpecs. HPE G2 Advanced Series Racks. Overview HPE G2 Advanced Series Racks Overview HPE G2 Advanced Series Racks HPE G2 Advanced Series Racks are designed for low-to-medium density IT configurations deployed in a diverse set of environments from the

More information

How to Sell APC s Cisco Approved Solution for Nexus 7018

How to Sell APC s Cisco Approved Solution for Nexus 7018 NetShelter SX Side Airflow Solution for Cisco Nexus 7018 How to Sell APC s Cisco Approved Solution for Nexus 7018 Objectives Explain Sales Strategy for the Side Airflow Solution for Nexus 7018 Explain

More information

QuickSpecs. HP Rack Series. Overview. HP Rack Series - 36U

QuickSpecs. HP Rack Series. Overview. HP Rack Series - 36U Overview - 42U - 36U - 22U DIM "A" 78.838 [2002.50] DIM "A" 68.338 [1735.78] DIM "A" 43.838 [1113.48] DIM "B" 24.125 [612.77] DIM "B" 24.125 [612.77] DIM "B" 24.125 [612.77] DA - 10995 Worldwide Version

More information

QuickSpecs. HP Rack G2 Series - top view

QuickSpecs. HP Rack G2 Series - top view DA - 12402 Worldwide Version 6 3.8.2007 Page 1 Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines

More information

QuickSpecs. HP Rack Accessories. QuickSpecs. Retired

QuickSpecs. HP Rack Accessories. QuickSpecs. Retired HP Rack and Power infrastructure solutions are the foundation you are looking for to help secure your long-term IT success. These products are designed to help you react to changes in the industry. They

More information

HPE Factory Express Customized Integration with Onsite Startup Service

HPE Factory Express Customized Integration with Onsite Startup Service Data sheet HPE Factory Express Customized Integration with Onsite Startup Service HPE Lifecycle Event Services HPE Factory Express Customized Integration with Onsite Startup Service (formerly known as

More information

HPE Factory Express and Deployment Service for HPE ConvergedSystem 700 solutions

HPE Factory Express and Deployment Service for HPE ConvergedSystem 700 solutions Data sheet HPE Factory Express and Deployment Service for HPE ConvergedSystem 700 solutions Support Services HPE Factory Express and Deployment Service for HPE ConvergedSystem 700 (CS700) for virtualization

More information

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU

More information

HPE Synergy Configuration and Compatibility Guide

HPE Synergy Configuration and Compatibility Guide HPE Synergy Configuration and Compatibility Guide Abstract This guide describes HPE Synergy hardware configuration options and compatibility. Hewlett Packard Enterprise assumes you are qualified in the

More information

QuickSpecs. What's New. HP Rack G2 Series Overview

QuickSpecs. What's New. HP Rack G2 Series Overview Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,

More information

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions. Designed for use with HPE Standard, Advanced,

More information

HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service

HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service Data sheet HPE ConvergedSystem 700 for Hyper-V Deployment Accelerator Service HPE Technology Consulting HPE ConvergedSystem 700 for Hyper-V is a solution that allows you to acquire and deploy a virtualization

More information

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network? Overview Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network? allow you to view and manage up to 256 rackmount servers across your data center

More information

16-Port Serial Console Server. 48-Port Serial Console Server

16-Port Serial Console Server. 48-Port Serial Console Server Overview The s provide remote access to up to 16 or 48 direct attached devices. The HP serial consoling solution utilizes CAT5 UTP cables to connect to any serially managed device, facilitating cable routing

More information

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for use with

More information

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network? Overview Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network? allow you to view and manage up to 256 rackmount servers across your data center

More information

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications The Cisco Unified Computing System is a next-generation data center platform that unites compute, network,

More information

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas One Dell Way Round Rock, Texas 78682 www.dell.com DELL ENTERPRISE WHITEPAPER MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES Dominick Lovicott Enterprise Thermal

More information

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information

More information

Replacing the Battery HP t5730 and t5735 Thin Clients

Replacing the Battery HP t5730 and t5735 Thin Clients Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows

More information

APC APPLICATION NOTE #146

APC APPLICATION NOTE #146 #146 Hot Aisle Containment Application Guidelines and Approved Configurations By Kevin Lemke Abstract The Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating

More information

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies.   PoE. Power over Ethernet Devices Installation and Getting Started Guide HP ProCurve 600/610 External Supplies www.hp.com/go/hpprocurve PoE over Ethernet Devices HP ProCurve 600/610 External Supplies Installation and Getting Started Guide

More information

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units Overview Setting new standards for reliable power distribution and metering HPE Advanced Series G2 Metered PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a

More information

QuickSpecs. What's New. HP Rack G2 Series - top view

QuickSpecs. What's New. HP Rack G2 Series - top view Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

QuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview

QuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview Overview are designed for lowtomedium density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA310 specifications for 19 inch racks, G2

More information

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes Part Number: 732171-007 Published: February 2017 Edition: 1 2017 Hewlett Packard Enterprise Development LP Notices The information contained

More information

QuickSpecs HP Rack 5642

QuickSpecs HP Rack 5642 Overview The HP 5642 rack, specifically designed for the value minded customer, is a revolutionary new rack that is assembled by the customer presenting significant savings while still proving to be a

More information

HPE Enhanced Network Installation and Startup Service for HPE BladeSystem

HPE Enhanced Network Installation and Startup Service for HPE BladeSystem Data sheet HPE Enhanced Network Installation and Startup Service for HPE BladeSystem HPE Lifecycle Event Services HPE Enhanced Network Installation and Startup Service for HPE BladeSystem provides configuration

More information

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment

More information

HP Modular Cooling System: water cooling technology for high-density server installations

HP Modular Cooling System: water cooling technology for high-density server installations HP Modular Cooling System: water cooling technology for high-density server installations technical brief Abstract... 2 Introduction... 2 Data center trends... 2 Increased power demands... 3 Increased

More information

QuickSpecs. HP Server Console Switches. HP Server Console Switches

QuickSpecs. HP Server Console Switches. HP Server Console Switches Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

HP Notebook Stands Overview. HP Adjustable Display Stand. HP Display and Notebook Stand HP Dual Hinge Notebook Stand. HP LCD Monitor Stand

HP Notebook Stands Overview. HP Adjustable Display Stand. HP Display and Notebook Stand HP Dual Hinge Notebook Stand. HP LCD Monitor Stand Introduction include a range of convenient solutions and space-saving designs that easily connect to your HP Business Notebook and enable easy viewing and an ideal desktop computing environment. Models

More information

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview Overview HPE Basic PDUs are designed to provide reliable and cost effective power distribution for your Hewlett Packard Enterprise and non-hewlett Packard Enterprise IT racks. Offering simple 0U and 1U

More information

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here Abstract This document describes how to install a StoreEver LTO Ultrium SAS internal tape drive and is intended for

More information

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks Guidelines June 2000 Prepared by: Storage Products Group Compaq Computer Corporation Contents Introduction...3 Rack Warnings...4 Telco Rack Option Kit for Compaq ProLiant DL360 Server Installation...5

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6960 32QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline 6960 32QSFP28 x86 ONIE AC Back-to-Front Switch JL279A JL280A Key features High 100GbE port density and low latency

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

StoreOnce 6500 (88TB) System Capacity Expansion Guide

StoreOnce 6500 (88TB) System Capacity Expansion Guide StoreOnce 6500 (88TB) System Capacity Expansion Guide Abstract This document explains how to install the StoreOnce 6500 System Capacity Expansion Kit, apply the new license, and add the new storage to

More information

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6960 32QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline 6960 32QSFP28 x86 ONIE AC Back-to-Front Switch JL279A JL280A Key features High 100GbE port density and low latency

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

HPE Aruba Airwave Installation and Startup Service

HPE Aruba Airwave Installation and Startup Service Data sheet HPE Aruba Airwave Installation and Startup Service Support Services HPE Installation and Startup Service for select Aruba Airwave products coordinates installation, configuration, and verification

More information

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview Overview (Supporting HP-UX and 64 Bit Linux Operating Systems on HP Integrity and HP 9000 Servers only) (Supporting HP-UX and 64 Bit Linux Operating Systems on HP Integrity and HP 9000 Servers/Workstations

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

QuickSpecs HP BladeSystem Breaker Panel

QuickSpecs HP BladeSystem Breaker Panel Overview The HP BladeSystem Breaker Panel is a dual input panel, where each input is rated for 240Amp, -36VDC to -72VDC. There are seven breakers on each input of the panel; where the first three are pre-configured

More information

Mounting and Cable Routing Procedures for Dell Digital KVM s (1082DS, 2162DS, 4322DS)

Mounting and Cable Routing Procedures for Dell Digital KVM s (1082DS, 2162DS, 4322DS) Mounting and Cable Routing Procedures for Dell Digital KVM s (1082DS, 2162DS, 4322DS) A Dell Technical White Paper Dell Datacenter Infrastructure Engineering By Daniel Whittaker and Jose L. Flores August

More information

HPE 3PAR Performance and Capacity Trending Service

HPE 3PAR Performance and Capacity Trending Service Data sheet HPE 3PAR Performance and Capacity Trending Service HPE Lifecycle Event Services HPE 3PAR Performance and Capacity Trending Service provides data collection, analysis, and reports with key performance

More information

Retired. Models HPE Altoline QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP+ x86 ONIE AC Back-to-Front Switch

Retired. Models HPE Altoline QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP+ x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6940 32QSFP+ PPC ONIE AC Front-to-Back Switch HPE Altoline 6940 32QSFP+ PPC ONIE AC Back-to-Front Switch HPE Altoline 6940 32QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms Problem Several cooling system mistakes are very common and avoidable Mistakes compromise availability and increase

More information

Improving Rack Cooling Performance Using Blanking Panels

Improving Rack Cooling Performance Using Blanking Panels Improving Rack Cooling Performance Using Blanking By Neil Rasmussen White Paper #44 Revision 1 Executive Summary Unused vertical space in open frame racks and rack enclosures creates an unrestricted recycling

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview Overview HP Basic PDUs are designed to provide reliable and cost effective power distribution for your HP and non-hp IT racks. Offering simple 0U and 1U installation options, HP Basic PDUs are available

More information

QuickSpecs. What's New. HP Intelligent Series Rack - top view

QuickSpecs. What's New. HP Intelligent Series Rack - top view Overview The family is the next generation of enterprise-class racks designed to meet the current and future requirements of demanding datacenters. It offers innovative intelligence capabilities for asset

More information

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series Overview Models HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Back-to-Front Switch HPE Altoline 6921 48XGT 6QSFP+ x86 ONIE AC Front-to-Back

More information

Setting new standards for reliable power distribution and metering

Setting new standards for reliable power distribution and metering Overview Setting new standards for reliable power distribution and metering HPE G2 Switched PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

HPE Data Center Operations Consulting Service

HPE Data Center Operations Consulting Service Data sheet HPE Data Center Operations Consulting Service HPE Packaged Consulting Services Data centers are large-scale capital investments that may not meet their capacity, availability, and operational

More information

QuickSpecs. HP Intelligent Series Rack Intelligent Series. Overview

QuickSpecs. HP Intelligent Series Rack Intelligent Series. Overview Overview The HP Intelligent Series Rack family is the next generation of enterprise-class racks designed to meet the current and future requirements of demanding datacenters. It offers innovative intelligence

More information

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches Table of Contents

More information

Netfinity White Paper Netfinity Technology Center

Netfinity White Paper Netfinity Technology Center Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes

More information

HPE 3PAR Remote Copy Extension Software Suite Implementation Service

HPE 3PAR Remote Copy Extension Software Suite Implementation Service Data sheet HPE 3PAR Remote Copy Extension Software Suite Implementation Service HPE Lifecycle Event Services HPE 3PAR Remote Copy Extension Software Suite Implementation Service provides customized deployment

More information

HPE Integrity MC990 X Server Getting Started Guide

HPE Integrity MC990 X Server Getting Started Guide HPE Integrity MC990 X Server Getting Started Guide Abstract This guide describes the HPE Integrity MC990 X Server computer system and provides information to get started using it. Part Number: 855699-003

More information

HPE Altoline XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline XG 6QSFP+ x86 ONIE AC Back-to-Front Switch

HPE Altoline XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline XG 6QSFP+ x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Back-to-Front Switch JL167A JL168A Key features High 10GbE port density and low

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

QuickSpecs. HP Server Console Switches Overview

QuickSpecs. HP Server Console Switches Overview Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be

More information

HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5

HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5 HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5 January 2016 This release note describes the enhancement, known restrictions, and errors found in the WBEM software and documentation,

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks) Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single

More information

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview Overview You cannot control what you cannot monitor. The new brings state of the art management and control to rack mounted power distribution units (PDU) to prevent over provisioning of power from restricting

More information

HPE Energy Efficiency Certification Service

HPE Energy Efficiency Certification Service Data sheet HPE Energy Efficiency Certification Service HPE Technology Consulting As power consumption and heat generation in the data center increase due to information explosion, big data, e-commerce,

More information

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell

More information

External Devices User Guide

External Devices User Guide External Devices User Guide Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services

More information

Powering HP BladeSystem c7000 Enclosures

Powering HP BladeSystem c7000 Enclosures Powering HP BladeSystem c7000 Enclosures HOWTO Abstract... 2 Power draw of HP BladeSystem c7000 Enclosure... 2 Power Distribution...2 Uninterruptible Power Supplies... 6 For more information... 9 Call

More information

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching

More information

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview QuickSpecs Overview (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to make the most of circuit capacity

More information

QuickSpecs. HPE Synergy QSFP+ Transceiver. Overview. HPE Synergy QSFP+ Transceiver. Page 1

QuickSpecs. HPE Synergy QSFP+ Transceiver. Overview. HPE Synergy QSFP+ Transceiver. Page 1 Overview Page 1 Platform Information Models Recommended This transceiver is a recommended option that has been selected by HPE experts to provide the right technology for a range of workloads and market

More information

QuickSpecs. HP 50 Modular Smart Array Enclosure. Overview

QuickSpecs. HP 50 Modular Smart Array Enclosure. Overview Overview The HP 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers

More information

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters.

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters. Overview The HPE Server Console Switch with Virtual Media is a key component in managing the data center. Connections for two local consoles (a console represents one keyboard, monitor and mouse) allow

More information

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER By David Moss Dell Data Center Infrastructure dell.com/hiddendatacenter Many people see an IT rack as a glorified shelving system.

More information

HPE RDX Utility Version 2.36 Release Notes

HPE RDX Utility Version 2.36 Release Notes HPE RDX Utility Version 2.36 Release Notes (RDX Tools 1.59) Abstract RDX Utility 2.36 (RDX Tools 1.59) enhances RDX Utility reporting for cartridges with a capacity greater than 2TB and implements Hewlett

More information

QuickSpecs. What's New. HP G2 Series Racks. Overview

QuickSpecs. What's New. HP G2 Series Racks. Overview Overview Designed for modern datacenters on a budget the HP 11000 G2 Series racks deliver all of the innovations HP racks have been known for while maintaining a focus on simplicity. Using the same fully

More information

HP Installation and Startup Service for HP Superdome 2

HP Installation and Startup Service for HP Superdome 2 HP Installation and Startup Service for HP Superdome 2 HP Services Technical data The HP Installation and Startup Service for HP Superdome 2 is designed to provide onsite installation of the HP Superdome

More information

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the T320 & T420 systems.

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment Part number: 5697-8185 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company,

More information