LAN Standards, News & Trends Update 2017 June 15, 2017

Size: px
Start display at page:

Download "LAN Standards, News & Trends Update 2017 June 15, 2017"

Transcription

1 LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist

2 Our Objectives Review new & ongoing applications work in IEEE Review new & ongoing work in Fibre Channel Review current TIA standards under revision & new work Review recently published TIA standards LEGRAND, NORTH AMERICA 2

3 IEEE Working group that develops standards for Ethernet based LANs 3

4 IEEE 802.3bs 200 Gb/s & 400 Gb/s Ethernet Task Force Task Force added 200 Gb/s capability to this project in May, 2016 to support a cost and performance optimized migration path to 400 Gb/s. Provide physical layer specifications, which support 200 Gb/s operation over: At least 500 m of 4-lane parallel SMF At least 2 km of SMF (4λ WDM duplex fiber) At least 10 km of SMF (4λ WDM duplex fiber) Provide physical layer specifications, which support 400 Gb/s operation over: At least 100 m of MMF (sixteen lanes/ 32 fibers total) At least 500 m of SMF (four lanes / 8 fibers total) At least 2 km of SMF (8λ WDM duplex fiber) At least 10 km of SMF (8λ WDM duplex fiber) Expect standard at end of

5 IEEE P802.3cd 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet NGOATH = Next Generation One And Two Hundred 5

6 IEEE 802.3bt DTE Power via MDI over 4-pair As of February, 2017 Split Type 3 & Type 4 to new clause (clause 145) Support Operation of 10GBASE-T Comply with SELV (Safety Extra Low Voltage) requirements as define in ISO/IEC Send 60w from PSE for PD (Type 3) Send 100w from PSE to get PD (Type 4) Uses all 4 pairs Expected Current levels 850mA to 1000mA per pair Expect standard in early

7 IEEE 802.3bt DTE Power via MDI over 4-pair Standard IEEE 802.3af IEEE 802.3at IEEE 802.3bt PoE PoE+ 4-pairs PoE or 4PPoE Type Status Released Released Expected early 2018 Maximum number of energized pairs Maximum DC current per pair 350 ma 600 ma 960 ma 960 ma Maximum power delivered by the Power Sourcing Equipment (PSE) 15.4 watt 30.0 Watt 60.0 Watt 99.9 Watt Minimum required power at the Powered Device (PD) Watt 25.5 Watt 51.0 Watt 71.0 Watt 7

8 IEEE 802.3cg 10Mb/s Single Twisted Pair Ethernet Objectives: Support 10Mb/s operation in automotive & industrial environments over single balanced twisted-pair cabling Support for optional auto-negotiation over single-pair Link Segment: up to 4 connectors for up to at least 15m Define link segment & PHY to support point-to-point operation with 10 inline connectors using balanced cabling (1-pair) for up to at least 1km Two amendments published already 802.3bw-2015: Amendment 1: 100Mb/s over single TP cable 802.3bp-2016: Amendment 4: 1Gb/s over single TP cable 8

9 IEEE 802.3cg 10Mb/s Single Twisted Pair Ethernet Why is TIA looking at this? Baseline frequency range from 100 khz to 20 MHz may consider additional link segment specifications as this progresses. IEEE P802.3cg Task Force is actively considering proposals for different link segments Benefits offered by generic cabling infrastructure in supporting other applications IEEE supportive of this concept inside buildings 9

10 Fibre Channel Standardized by International Committee for Information Technology Standards, or INCITS, T11 Technical Committee 10

11 Fibre Channel FC 32G PI-6 / FC 128G PI-6P completed (bit rate 28.05Gbps) FC 64G per fiber PI-7 & FC 256G PI-7P (bit rate 56.1 Gbps per fiber) Still facing several challenges for 64G FC using PAM-4 using work from IEEE 802.3bs Clause 121 (closely related 50GBASE-SR and 64GFC MM variants) Wideband Multimode Fiber (WBMMF)/OM5 Fibre Channel Looks like this will be a transceiver media option for PI-7 (use two or four wavelengths for 64G/256G variants) Requirements for Link Speed Negotiation for transceiver modules (backwards compatibility to 32G) in development, including transmitter training for FC-PI-7 and new requirements for LSN for SFP & QSFP modules Breakout use cases will not be documented in std. (but could be implemented by vendors) Possibility of draft publication by June

12 Fibre Channel Speeds 12

13 Fibre Channel Ports Shipped Annually Source: Dell Oro 13

14 TR-42 Engineering Committee on Telecommunications Cabling Systems 14

15 TIA Standards Update Engineering Committee Develops standards for telecommunications cabling infrastructure Standards cover many different premises, i.e. data center, commercial building, residential, healthcare facility, education facility, etc. Standards are grouped into 3 categories: Common, Premises and Cabling & Components Currently 9 working subcommittees 15

16 TR-42.1 Subcommittee on Generic Cabling & Commercial Building Cabling 16

17 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress: D (Generic) working on Addendum 1 Updated References & New Media Types 2 nd industry ballot D (Commercial) working on Addendum 1 Updated References & New Media Types 2 nd industry ballot 17

18 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress: TIA-1179-A (Healthcare) Revision A default ballot TIA-942 (Data Centers) Revision B Default ballot 18

19 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress : TIA-1179-A Healthcare Standard Significant technical changes References were updated Balanced twisted-pair backbone & horizontal cabling - cat 6A minimum OM4 is minimum recommended Minimum two fibers required for fiber backbone cabling Array connectors now permitted in work area MUTOA & Consolidation Points may be used as additional network elements 19

20 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress : TIA-1179-A Healthcare Standard Significant technical changes continued: Requirements were added for: pathways and spaces (additional requirements to those in ANSI/TIA-569-D) bonding and grounding fire stopping broadband coaxial cabling multi-tenant building spaces Recommendations were added for cabling for: wireless access points distributed antenna systems 20

21 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress : TIA-942-B Data Center Standard Significant technical changes: Added MPO-16, MPO-32 (ANSI/TIA ) & MPO-24 (ANSI/TIA-604-5) Added category 8 Changed recommendation to category 6A or higher Added wideband laser-optimized 50/125 um multimode (OM5) Added 75-ohm broadband coaxial cables & connectors (ANSI/TIA-568.C-4) Added recommendations for fiber in non-continuous pathways that could cause micro bends 21

22 TR-42.1 Commercial Building Telecommunications Cabling Work in Progress : TIA-942-B Data Center Standard Significant technical changes continued: Recommends that cabinets be at 1200 mm (48 ) deep and to consider cabinets wider than 600 mm (24 ) wide. Recommends considering pre-terminated cabling to reduce installation time & improve consistency and quality of terminations. Recommends considering need for proper labeling, cable routing, cable management, and ability to insert and remove cords without disrupting existing or adjacent connections. Maximum cable lengths for direct attach cabling in EDAs reduced from 10 m (33 ft.) to 7 m (23 ft.). Direct attach cabling between rows is not recommended. 22

23 TR-42.1 Commercial Building Telecommunications Cabling New Work: ANSI/TIA-570-C (Residential) Project request to start D revision approved Targeted for 1 st industry ballot in next meeting cycle ANSI/TIA-758-B (OSP) Project request to start C revision approved 1 st industry ballot based on editors schedule 23

24 TR-42.1 Commercial Building Telecommunications Cabling New Work: ANSI/TIA-862-B (IBS) Approved project request to create Addendum 1 Targeted for 1 st industry ballot in next meeting cycle ANSI/TIA-4966 (Education) Approved project request to create Addendum 1 Targeted for 1 st industry ballot in next meeting cycle 24

25 TR-42.1 Places of Assembly Task Group New Work: Task group work re-started end of last year Evaluating need for standard for premises not covered by other standards Based on IBC Assembly group classifications Call for interest Next call April 28 th, 1-2 PM eastern Monthly calls Don t need to be a TIA member to participate in a task group cindy.montstream@legrand.us if interested 25

26 TR-42.3 Subcommittee on Pathways & Spaces 26

27 TR-42.3 Commercial Building Telecommunications Pathways and Spaces TIA-569-D-2 Pathways & Spaces for Remote Powering Provides additional guidelines for pathway systems supporting copper telecommunications cabling used for remote power delivery Going out for 2 nd Committee Ballot 27

28 TR-42.6 Administration 28

29 42.6 Telecommunications Infrastructure & Equipment Administration ANSI/TIA-5048 Adaption of ISO/IEC AIM Standard Added reference to ANSI/TIA-606-C ANSI/TIA-606-C Finalizing C revision Out for default ballot Publish if no technical comments or no votes Addendum TIA-606-B-1 replaced with reference to ANSI/TIA-5048 Include content (Annex D) regarding administration of remote powering 29

30 42.6 Telecommunications Infrastructure & Equipment Administration TIA-606-C Significant Technical Changes: Changed telecommunications bonding & grounding identifier schemes (ISO/IEC & ANSI/TIA-607-C) Legacy terms may also be used. BCT > TBC RGB > RBB GE > BBC TMGB > PBB TGB > SBB Added a table with all of the variables used in the identifier formats. Renamed some of the variables to avoid duplication n used for sequential cable number (was L ) L used for slot, card, module variable (was s ) 30

31 TR-42.7 Subcommittee on Copper Cabling Systems 31

32 TR-42.7 Telecommunications Copper Cabling Systems Working on ANSI/TIA/568.2-D (TP copper) 1st committee ballot Performance specifications are provided for category 8 shielded balanced twisted-pair cabling & components ANSI/TIA D (coax) 2nd industry ballot 32

33 TR-42.7 Telecommunications Copper Cabling Systems Task Group Activities: End plug application & testing (adding to D) Will add as ANNEX D in TIA D Study 28 AWG patch cords Study patch cord measurement Study transmission properties at temps. Above 60 C Participation in joint TG on 1-pair cabling Studying connector selection for IEEE cg application 33

34 Fiber Subcommittees TR Subcommittee on Optical Fiber Systems TR-42.12: Subcommittee on Optical Fiber & Cables TR-42.13: Passive Optical Devices and Fiber Optic Metrology 34

35 TR Optical Fibers and Cables Ongoing work: Revising TIA-598D Addendum 1: Specs for colors TG formed for round robin on color measurement for colors 13-16; 2 nd industry ballot Addendum 2: Jacket color for WBMMF Approval of Lime for jacket color for OM5 fiber applications. 35

36 Completed Standards 36

37 Wide Band Multimode Fiber ANSI/TIA-492AAAE Wide Band Multimode (WBMMF) 50µ Laser Optimized Multimode Fiber Use cost effective MM VCSEL technology Optimized to support at least 4 wavelengths OM5 designation Backwards compatible Continue to support legacy 850nm OM4 applications No additional field testing required Field polished the same way as any other MMF Published 06/

38 TR-42.12/42.11 Joint Project Wide Band Multimode (WBMMF) SWDM (4λ over 1 fiber) 38

39 Specifications for 100Ω Category 8 Cabling ANSI/TIA 568-C.2-1 FTP Cable: 22 AWG to 24 AWG Cord cable: 22 AWG to 26 AWG RJ-45 2-connector channel 24m PL De-rating of PC length based on AWG Equipment cord de-rating factor Length of cordage allowed (m) 0 % (22/23 AWG) 8 (TBD) 20 % (24 AWG) 6 (TBD) 50 % (26 AWG) 4 (TBD) Note: This is based on max permanent link length of 24m 39

40 Optical Fiber Cabling Components ANSI/TIA D Now components & cabling (testing, polarity, etc.) Splitters will be part of budget MMF loss at 850nm changes from 3.5dB/km to 3.0dB/km Changed return loss for single-mode from a minimum of 26 db to a minimum of 35 db Harmonizes with IEEE Will make more difficult to field terminate Published 09/

41 Field Test Requirements for Balanced TP Cabling ANSI/TIA-1152-A (2G field testing for cat 8) Requirements for Field Test Instruments and Measurements for Balanced Twisted-Pair Cabling Field Tester Accuracy Levels Cabling Standard Frequency Range (MHz) Accuracy Level CAT 5e 100 Level II CAT Level III CAT 6A 500 Level IIIe CAT 8 2,000 Level 2G ISO-only Accuracy Levels (ISO ) Cabling Standard Frequency Range (MHz) Accuracy Level CLASS F 600 Level IV CLASS FA 1000 Level V (draft) 41

42 Guidelines for Supporting Power Delivery over TP Cable TIA-TSB-184-A (support for 4-pair remote power) Provides guidelines for supporting power delivery over twistedpair cabling simultaneously with data Twisted-pair cabling defined in ANSI/TIA-568 series Safety Extra Low Voltage (SELV) limited power source (LPS) power Describes methods to help manage temperature rise ( 15º C) Defines bundle sizes Includes 26 AWG Installation recommendations Approved for publication at last meeting 42

43 Structured Cabling Guidelines for Distributed Antenna Systems TIA TSB-5018 (DAS) Published 06/2016 The media used for Cabling Subsystem 1, 2, and 3 for DAS are: Multimode optical fiber cabling (see ANSI/TIA D) Single-mode optical fiber cabling (see ANSI/TIA D) Broadband coaxial cabling (see ANSI/TIA-568-C.4) Coaxial cabling per equipment manufacturer s recommendations Balanced twisted pair cabling (see ANSI/TIA-568- C.2) Hybrid cabling supporting both fiber (communications) and copper (power) elements in the same sheath Common cellular grid design of cabling can support both DAS and wireless access points (see TIA TSB-162-A)

44 Supporting 2.5G/5.0G With Existing Cabling TIA-TSB-5021 Support of 2.5GBASE-T & 5GBASE-T (as specified in IEEE 802.3bz) using existing cabling (cat 5e & cat 6) Alien crosstalk mitigation procedures Internal parameter mitigation procedures Cat 6a supports both 44

45 Other Published ANSI/TIA Standards ANSI/TIA-569-D-1 Pathways & Spaces Addendum 1: Updated ASHRE ANSI/TIA-607-C-1 Bonding & Grounding Addendum 1: Bonding in Multi-Tenant Buildings Published 01/2017 ANSI/TIA-862-B Intelligent Building Systems Structured Cabling Published 02/2016 ANSI/TIA-5017 Physical Network Security Standard Published 02/2016

46 How do I get a copy of the standards? All published standards can be purchased directly from TIA or through IHS (formerly known as Global Documents) 46

47 Thank you for your time 47

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic

More information

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only 1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda

More information

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,

More information

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications

More information

Atras Network Communications

Atras Network Communications Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry

More information

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org

More information

Industry Standards Activity Overview

Industry Standards Activity Overview Industry Standards Activity Overview Most Recent Plenary Meeting: June 12-16, 2017 in Quebec City, QC, CAN Updated: July 7, 2017 TR-42.1 Commercial Building Cabling: TIA TSB-185 Environmental Classification

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement Overview SPE is poised to enable a new class of low power devices that

More information

November 2013 IEEE 802.3

November 2013 IEEE 802.3 TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Telecommunications Cabling Systems Engineering Committee November, 2013 Dallas, TX 1 Introduction to TIA Telecommunications Industry

More information

Fiber Optic Cabling Systems for High Performance Applications

Fiber Optic Cabling Systems for High Performance Applications Fiber Optic Cabling Systems for High Performance Applications BICSI Conference Bangkok, Thailand 17-18 November 2016 Nicholas Yeo, RCDD/NTS/DCDC Data Center Trends Computing evolution Cloud computing Servers

More information

November 2010 IEEE 802.3

November 2010 IEEE 802.3 TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire Vice Chair, TIA TR-42 Vice Chair, TIA TR-42.7 November, 2010 Dallas, TX 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org TR-42:

More information

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008 LAN Standards, News & Trends Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008 October 16, 2008 Objectives Review the recent events and activities of the TIA TR-42 Subcommittees Review

More information

History of Standards

History of Standards History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures

More information

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring Cabling to support 802.11ac and beyond Nate Herring Sr. Product Manager Hubbell Premise Wiring IP Traffic Continues to Increase Globally, IP traffic will grow 3-fold from 2014 to 2019, a compound annual

More information

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions Tim Takala RCDD Vice President Field Application Engineer APAC Mobility is Driving Changing Network Architectures & Transceiver Evolutions 5TOP TRENDS SHAPING NETWORKS 1. Mobility 2. Connected Devices

More information

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Industry Standards in ICT Enabled Projects Reading and Applying the Fine Print Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland

More information

Optical Fiber Premises Standards News & Trends

Optical Fiber Premises Standards News & Trends 1 Optical Fiber Premises Standards News & Trends Herb Congdon Tyco Electronics Updated: October 2005 hvcongdon@tycoelectronics.com 2 IEEE Ten Gigabit Ethernet (10GBASE-F) Published as IEEE802.3ae in June

More information

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher

More information

Certification for 10G copper cabling

Certification for 10G copper cabling Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards

More information

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope Choosing MPO Connectors for the Data Center Ken Hall, RCDD, NTS Data Center Architect CommScope Agenda Network Architecture changes Data Center & MPO Standards Application comparisons Additional considerations

More information

Fiber in Data Centers What s Next? Srinivasan B, RCDD

Fiber in Data Centers What s Next? Srinivasan B, RCDD Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:

More information

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1

More information

Implementation considerations for cabling supporting remote powering

Implementation considerations for cabling supporting remote powering Implementation considerations for cabling supporting remote powering Table of contents Background...3 Advantages of remote powering using communications cabling...4 CommScope implementation considerations

More information

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit NGEAB-T Use Cases Berlin, Germany February 2015 Chris DiMinico MC Communications/Panduit cdiminico@ieee.org 1 Scope Next Generation Enterprise Access BASE-T PHY Study Group to define use cases and deployment

More information

The Power of PoE: Converging Power and Control of Intelligent Devices

The Power of PoE: Converging Power and Control of Intelligent Devices The Power of PoE: Converging Power and Control of Intelligent Devices Amir Sekhavat Global Director, Copper Product Management and Enterprise Market Development Superior Essex Objectives What drives the

More information

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications Telecom 2017 Corning Restricted Incorporated 2 Server Access Switch

More information

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond Leaders in the Advancement of Multimode Fiber Fiber Future and Beyond Major Milestones in the Advancement of Multimode Fiber (MMF) Transmission OM4 Signature Core Fiber Cabling TIA WBMMF ISO/IEC OM5 (WBMMF)

More information

Optical Fiber Networks: Industry. and New Options for Networks

Optical Fiber Networks: Industry. and New Options for Networks Optical Fiber Networks: Industry Trends, Application Influences and New Options for Networks Herbert V Congdon II, PE Manager, Standards & Technology Tyco Electronics AMP NETCONNECT Solutions Preview Deciding

More information

Copper Cabling Standards

Copper Cabling Standards Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals

More information

Anixter Standards Reference Guide

Anixter Standards Reference Guide Anixter: The Cabling System Experts Anixter is a leading global supplier of communications and security products, electrical and electronic wire and cable, fasteners and other small components. We help

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

NGBASE-T Cabling Requirements

NGBASE-T Cabling Requirements NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T

More information

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions A Fork in the Road OM5 vs. Single-Mode in the Data Center Gary Bernstein, Sr. Director, Product Management, Network Solutions Outline Definition of Enterprise and Cloud Data Centers The Growth of Cloud

More information

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Fiber Optics LAN Section Part of the Telecommunications Industry

More information

What s the technology Buzz at the 2017 Optical Fiber Communications Conference?

What s the technology Buzz at the 2017 Optical Fiber Communications Conference? 40G 100G.400G 800G? What s the technology Buzz at the 2017 Optical Fiber Communications Conference? Lylette Macdonald, RCDD Legrand Data Communications Division lylette.macdonald@legrand.us The Future

More information

(Data Center Networks & Cloud Computing Security)

(Data Center Networks & Cloud Computing Security) BPSDC (Data Center Networks & Cloud Computing Security) Lecture 3 Data Center Standars Service Level Agreement 2 Building a Data Center is just a Start What is Service Level Agreement (SLA)? An official

More information

Standards Update. by Paul Kish NORDX/CDT

Standards Update. by Paul Kish NORDX/CDT Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline

More information

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager Overcoming the Testing Challenges of 40G and Beyond Eric Farst Channel Sales Manager Agenda Introduction Increased demand for speed & capacity in the Enterprise/Data Center How Enterprises/Data Centers

More information

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit

More information

FREQUENTLY ASKED QUESTIONS (FAQs)

FREQUENTLY ASKED QUESTIONS (FAQs) FREQUENTLY ASKED QUESTIONS (FAQs) Q. What is the standard that governs Power over Ethernet? The standard governing Powered Ethernet is IEEE 802.3af Data Terminal Equipment (DTE) Power via Media Dependent

More information

Structured Cabling Organizations and Standards

Structured Cabling Organizations and Standards since 1976 Structured Cabling Organizations and Standards Key cabling infrastructure standards ANSI/TIA ISO/IEC 724-746-5500 blackbox.com IEEE Introduction Table of Contents The importance of standards...

More information

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett Testing Considerations for Beyond 10Gigabit Ethernet Erin Hallett JDSU Agenda Intro Need for Speed Growth of IP traffic Fiber vs. Copper Fiber Tightening requirements Testing considerations and practices

More information

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional

More information

IEEE P802.3bt Guidelines For Field Deployment

IEEE P802.3bt Guidelines For Field Deployment IEEE P802.3bt Guidelines For Field Deployment Chris DiMinico MC Communications/Panduit cdiminico@ieee.org 1 Background Power delivery over BASE-T PHYS with specified operation over TIA/ISO cabling 802.3af,

More information

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises Corrigendum 1 to Amendment 2 1 ISO/IEC 11801 ISO/IEC 11801 (second edition 2002) Information technology Generic cabling for customer premises Amendment 2 (2010) CORRIGENDUM 1 Corrigendum 1 applies to Amendment

More information

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions Trends in Testing Data Center Infrastructure Ed Gastle VIAVI Solutions Agenda INTRODUCTION Modern Data Center Architecture Historically Enterprise has been a 3 tier topology Core, Aggregation, Access Cloud

More information

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS. Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets

More information

Data center applications standards reference guide

Data center applications standards reference guide White paper Data center applications standards reference guide Networking and storage Contents Scope 3 Introduction 3 Data center cabling standard ISO/IEC 24764 3 Ethernet (IEEE 802.3) 4 Proprietary 40

More information

High Speed Migration 100G & Beyond

High Speed Migration 100G & Beyond High Speed Migration 100G & Beyond Moses Ngugi Field Application Engineer 5th September 2017 BANDWIDTH GROWTH Mobile Data IP Video Global Cloud IP Traffic Global IP Traffic Cisco CAGR: 50+% CAGR: 35%+

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3 Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation IEEE 802.3 Draft 0.3 Agenda Overview Discussion Presenter 1 Presentations Market Drivers Presenter 2 Technical

More information

Keeping up to Speed with High Data Rate Fiber Solutions. Eric Leichter Manager, Training and Technology

Keeping up to Speed with High Data Rate Fiber Solutions. Eric Leichter Manager, Training and Technology Keeping up to Speed with High Data Rate Fiber Solutions Eric Leichter Manager, Training and Technology Keeping up to Speed with High Data Rate Fiber Solutions Global Standards Update OM4 Optical Fiber

More information

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies. 1 ISO/IEC SC25 WG3 Who are they & what can they do for 802.3cg? Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Who are ISO/IEC SC25 WG3? Ø International systems group

More information

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF Data Sheet Highlights Compact Quad Small Form-factor Pluggable (QSFP28) products for high density 100Gb Ethernet applications Hot swappable, field serviceable modular interfaces for Extreme Networks switches

More information

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

DELL EMC NETWORKING TRANSCEIVERS AND CABLES DELL EMC NETWORKING TRANSCEIVERS AND CABLES Features and benefits Hot-swappable for simplified maintenance (no power-down required for installation or replacement) Some of the smallest and lowestpower

More information

Ethernet evolution: what s new and what s next

Ethernet evolution: what s new and what s next Ethernet evolution: what s new and what s next Greg Hankins European Peering Forum 2016 1 Nokia 2016 EPF 2016 2016/09/19 I ve been giving presentations about Ethernet developments

More information

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect How to Decide on Optical Fibre Termination Options Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect Termination Choices Optical Fiber Cabling in Data Center Options available Traditional

More information

Wideband Multimode Fiber What is it and why does it make sense?

Wideband Multimode Fiber What is it and why does it make sense? White Paper Wideband Multimode Fiber What is it and why does it make sense? March, 2015 Contents Executive summary 3 A brief history of MMF 3 The role of fiber connectors 4 Introducing WBMMF 5 2 Executive

More information

Optical Fiber for Today s Premises Applications

Optical Fiber for Today s Premises Applications Optical Fiber for Today s Premises Applications Tony Irujo Customer Technical Support Mgr. OFS Optical Fiber Division 508-347-8582 tirujo@ofsoptics.com 1 Copyright 2006 Fitel USA Corp., All rights reserved.

More information

Yuna Shin Leviton Network Solutions

Yuna Shin Leviton Network Solutions Y Yuna Shin Leviton Network Solutions Presenter Bio Yuna Shin Senior Product Manager, Copper Leviton Network Solutions Bothell, WA U.S.A. Manages Leviton's extensive selection of Category 6A, 6, and 5e

More information

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 15018 First edition 2004-06 Information technology Generic cabling for homes ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may

More information

Everything you wanted to know about cabling, but were afraid to ask

Everything you wanted to know about cabling, but were afraid to ask Everything you wanted to know about cabling, but were afraid to ask Join the teleconference To receive a call back, click Communicate/Teleconference/Join Teleconference. In the pop-up window, enter your

More information

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output

More information

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

STANDARDS REFERENCE GUIDE ANIXTER anixter.com. Products. Technology. Services. Delivered Globally.

STANDARDS REFERENCE GUIDE ANIXTER anixter.com. Products. Technology. Services. Delivered Globally. ANSI/TIA-568-C.0 ANSI/TIA-568-C.1 ANSI/TIA-568-C.2 ANSI/TIA-568-C.3 ANSI/TIA-569-D ANSI/TIA-606-B ANSI/TIA-607-C ANSI/TIA-862-A ANSI/TIA-942-A ANSI/TIA-1005-A ANSI/TIA-1179 ISO/IEC 11801 IEEE 802.3af IEEE

More information

THE OFFICIAL TRADE JOURNAL OF BICSI. November/December 2015 Volume 36, Number 6

THE OFFICIAL TRADE JOURNAL OF BICSI. November/December 2015 Volume 36, Number 6 ICT TODAY THE OFFICIAL TRADE JOURNAL OF BICSI November/December 2015 Volume 36, Number 6 COVER STORY 2 ICT TODAY By Valerie Maguire, BSEE and Betsy Conroy In the data center environment, copper and optical

More information

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Singapore: January 2017

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Singapore: January 2017 1 ISO/IEC SC25/WG3 Meeting Singapore: 16-20 January 2017 - Customer Premises Cabling - Key Items: 1. ISO/IEC 11801 Ed.3 major revision - DIS ballot positive and progressing to FDIS - final draft (contains

More information

10 Gigabit Ethernet and Future Cabling for Offices + Data Centres

10 Gigabit Ethernet and Future Cabling for Offices + Data Centres 10 Gigabit Ethernet and Future Cabling for Offices + Data Centres Presentation at Nexans Seminar Scandinavia, May 2006 Dr Alan Flatman Principal Consultant LAN Technologies Topics 1. 10 Gig over optical

More information

The Real Impact of High Power PoE on Your IP Network

The Real Impact of High Power PoE on Your IP Network The Real Impact of High Power PoE on Your IP Network Jason Finnegan, Product Manager Copper Solutions, Legrand Cindy Montstream, Director of Technical Support & Training, Legrand Amir Sekhavat, Global

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

Laying the groundwork for a new level of Power over Ethernet

Laying the groundwork for a new level of Power over Ethernet Laying the groundwork for a new level of Power over Ethernet October 2018 Table of contents Laying the groundwork for a new level of Power over Ethernet...3 PoE basics...4 PoE standards development...5

More information

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya DC Center Copper Cabling up to 40Gbase-T Halim Senjaya CTDC CTIA Data Center Expert Datwyler Singapore Diploma in Eng ng in Physics Bandung IT Diploma in Cloud DC Technologies - NP MBA Middlebury Institute

More information

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX KGC-352 Series Installation Guide DOC.070820-KGC-352-1- (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation

More information

Power Patch Panel. Your head end solution for media conversion & PoE extension

Power Patch Panel. Your head end solution for media conversion & PoE extension Your head end solution for media conversion & PoE extension PRODUCT OVERVIEW Power Patch Panel NO MORE 90 METER LIMITS! Drive PoE up to 4750 meters from the head end of your network PoE powered devices

More information

Meeting updated ISO/IEC Your professional partner of structured cabling system

Meeting updated ISO/IEC Your professional partner of structured cabling system Meeting updated ISO/IEC11801 Premium Line Systems Group Premium Line Systems GmbH, Based in Germany, it is the worldwide headquarter 25 Years experience in Cabling and Networking products End-to-End comprehensive

More information

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope Connected & Efficient Building Field Application Engineer - Kutlugün Sürmeli CommScope Low Voltage Over Twisted Pair Revolution Desktop Voice and Data WiFi Access Control Security Cameras Occupancy Sensors

More information

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure Power Over Ethernet with Panduit Copper Cabling How To Create More Meaningful Connections With The Highest Performing Infrastructure Introduction Increasing usage of Power over Ethernet (PoE) represents

More information

Fiber backbone cabling in buildings

Fiber backbone cabling in buildings White paper Fiber backbone cabling in buildings www.commscope.com 1 Contents Introduction 3 Backbone cabling speeds 3 Optical fiber in the backbone 3 10 Gbps optical fiber backbone 3 Migrating to 40 Gbps

More information

ISO/IEC TR Guidance on 40GBASE-T T Cabling

ISO/IEC TR Guidance on 40GBASE-T T Cabling 1 ISO/IEC TR 11801-99 99-1 Guidance on 40GBASE-T T Cabling - a tutorial - Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Content 1. introduction to ISO/IEC SC25 WG3

More information

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions Leveraging the Structured Cabling System for Security Applications Mark Dearing, RCDD Leviton Network Solutions Trends - Cable Category Mix Source: Leviton projections based on market growth rates Over

More information

PANGEN SYSTEM WARRANTY. Warranty Guide

PANGEN SYSTEM WARRANTY. Warranty Guide PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &

More information

Telecommunication Cabling Standards to address IoT and power delivery. 5 October

Telecommunication Cabling Standards to address IoT and power delivery. 5 October Telecommunication Cabling Standards to address IoT and power delivery 1 5 October 2018 www.vti.net.au In a nut shell Out for comment NOW AS/NZS 11801.1 (General requirements) AS 11801.2 (Office) AS 11801.3

More information

Optical Trends in the Data Center

Optical Trends in the Data Center Optical Trends in the Data Center Romeo Lazar Sales Manager, Eastern Europe Corning Optical Communications EMEA September 2016 Agenda Agenda Corning overview Data Center Server and Switch Trends Standards

More information

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant Is Cable Balancing Efficient i Enough for EMI Mitigation in Data Centers? Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant What are You going to Learn? What are the potential sources

More information

CERTIFICATION PLUS SM

CERTIFICATION PLUS SM CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation

More information

Data Center Optical Connectivity with Bend-Optimized OM3/OM4 Multimode Optical Fiber

Data Center Optical Connectivity with Bend-Optimized OM3/OM4 Multimode Optical Fiber Data Center Optical Connectivity with Bend-Optimized OM3/OM4 Multimode Optical Fiber Doug Coleman Corning Cable Systems Manager, Technology & Standards Data Center Environment Data Center Environment Higher

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Prepare for Ludicrous Speed! Kelly Urbanik Programs Specialist

Prepare for Ludicrous Speed! Kelly Urbanik Programs Specialist Prepare for Ludicrous Speed! Kelly Urbanik Programs Specialist Yesterday Yesterday The Birth of Ethernet The Development Cycle 10BASE-T 100BASE-T Gigabit Ethernet Fiber Twisted Pair 10 Gigabit Ethernet

More information

The Real Impact of High-Power PoE on Your IP Network

The Real Impact of High-Power PoE on Your IP Network The Real Impact of High-Power PoE on Your IP Network Jason Finnegan, Product Manager Copper Solutions - Legrand Cindy Montstream, RCDD, NTS - Director of Technical Support & Training - Legrand Brian Ensign,

More information

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly

More information

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Ethernet seems to be one of the fastest

More information

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents

More information

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution 1 2 Agenda 1. Wirewerks introduction 2. Wirewerks products overview Data Center: Next Step TM Confidential Information Wirewerks

More information

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers Page 1 of 5 Title Demonstrate knowledge for telecommunications premises network cablers Level 2 Credits 2 Purpose This unit standard is for people installing and maintaining telecommunications cables on

More information

10 GB Ethernet: Copper or Fiber? Choosing the Right Media for the Application

10 GB Ethernet: Copper or Fiber? Choosing the Right Media for the Application 10 GB Ethernet: Copper or Fiber? Choosing the Right Media for the Application Outline Why 10 GB Ethernet? Current Standards Copper Choices Fiber Choices Comparison Summary Why 10 GB Ethernet? Aggregation

More information

1 of 5 12/31/2008 8:41 AM

1 of 5 12/31/2008 8:41 AM 1 of 5 12/31/2008 8:41 AM SAVE THIS EMAIL THIS Close All multimode fiber is not created equal By Robert Reid Bandwidth, reach, and cost are among the key factors you ll need to weigh. Multimode fiber cabling

More information

Deploying NBASE-TTM 2.5G/5GBASE-T Technologies

Deploying NBASE-TTM 2.5G/5GBASE-T Technologies Deploying NBASE-TTM 2.5G/5GBASE-T Technologies George A. Zimmerman, Ph.D., CME Consulting Board of Directors, NBASE-T Alliance Peter Jones, Cisco Systems Chairman, NBASE-T Alliance Masood Shariff, CommScope

More information