Integralna rešenja Infrastrukture Data Centra

Size: px
Start display at page:

Download "Integralna rešenja Infrastrukture Data Centra"

Transcription

1 1

2 2 Integralna rešenja Infrastrukture Data Centra Jason Dodier, Solutions Business Development Manager - Global Sales (Schneider Electric) Overview of Prefabricated DC's market Prefab - needs to be satisfied One vendor for critical applications Applications and added values end user verticals

3 Confidential Property of Schneider Electric 3 3

4 4 Prefabricated Chilled Water Plant Prefabricated UPS and Switchgear Prefabricated IT Infrastructure

5 5 Value proposition. Pain-points Prefabricated Datacenter Modules address. 5

6 6 Prefabricated data center advantages... Flexibility and Scalability Faster Deployment Predictable Performance Defer capital expenses and minimize over sizing. Adjust quickly changes in your demand, up or down. Build in smaller, more granular phases Shorten planning cycle and reduce complexity Simplify build process Delivery in weeks or less (upon design sign-off and receipt of PO) The density, availability and efficiency you expected The cost you were promised Less changes to your design... vs. traditional data centers

7 7 Simplify Lifecycle Services with Prefabrication Minimize design work to module and site layout, common connections, and local codes Reduce on-site construction and coordination Simplify planning process with 35 Prefab Reference Designs Minimize on-site programming and configuration with integrated DCIM software Are Prefabricated Data Center Module the right fit?

8 Confidential Property of Schneider Electric 8 If you have any of these issues > Out of space or capacity in my current data center > Need to set up small server rooms at our branch offices (or remote locations). > Only have a few months to build a new data center > Data center needs to be near our production facility > Have access to a unfinished building shell that I plan to convert to whitespace. > Need to add capacity quickly when my customers demand increases (colo). then Prefabricated Modules could be a good solution

9 9 The Industry has focused on cost savings as a driver to use prefabricated modules > There are significant cost advantages that can be achieved, but prefabrication is not always cheaper depends on density, growth plans, size, application. > Most customers that have deployed prefabricated modules had a specific business need. > Need to deploy quickly > High cost to retrofit building power and/or cooling > Scalability and Deferred cost > Predictability and minimizing risk > Build or Buy > Industrial environment

10 10 Product Offer/Base Designs 10

11 Confidential Property of Schneider Electric 11 Right size your solution Not one-size-fits-all Power Power Increments between 200kW 1.2MW IT Space IT solutions from 1 Rack 200 Racks Cooling Technologies: DX Chilled Water Direct Air Indirect Air

12 Base Designs IT Room Modules Power Modules Cooling Modules 90kW All-in-One 250kW 20ft Enclosure with UPS, Switchgear, cooling, DCIM 500kW Hydronics Modules (Support 3-250kW Chillers) 110kW Single Module 240kW Dual Module 500kW 40ft Enclosure with UPS, Switchgear, cooling, DCIM 1000kW Hydronics Modules (Support 3-500kW Chillers) kW Dual Module Confidential Property of Schneider Electric 1.2 MW Skid mounted, UPS, Switchgear, DCIM Chiller Skids & Enclosures Packaged Chiller, pump, and Tank with connecting piping 12

13 IT Module Detail 2 bay, In-Row, 240kW shown Fire-rated, insulated and sealed wall construction with metal clad exterior to provide safe and secure IT room for each customer Cold and Hot Aisles are isolated with a built-in containment system to provide efficient cooling and airflow control Isolated entrance and service area for mechanical and electrical systems Confidential Property of Schneider Electric Each block is protected with it s own fire detection and suppression system Configurable space for 20-24, 48 deep racks Aisles are standard width for easy access and functionality 13

14 14 Custom Multi-Module Example Design 500kW TierIII 120 Rack System 4kW/rack average Non-ISO Prefabricated Module design Indirect Air Economizer with Natural Free Cooling Modules Cooling Modules installed inside building with mechanical heat rejection to air cooled chiller plant outside Buss Bar Power distribution to the rack Indirect Air Economizer Modules Entrance and Electrical Distribution Modules 20 Racks per module x 6 Modules

15 15 Form Factors/Modules by Type 15

16 Module Enclosure SmartShelter Modules Overview Non-ISO design is wider, taller, deeper than a shipping container and engineered to provide a spacious, functional workspace for IT personnel Efficient, scalable design allows for custom, multimodule configurations Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row) Robust frame design simplifies installation and ganging together Best option for a complete configurable space

17 Module Enclosure SmartShelter Container Overview Containers are typically used in more industrial applications, harsh environments, and remote areas that have limited access for transportation. They are rugged, environmentally sound and easily transportable anywhere in the world. ISO shipping container is defined to 8ft (2.4m) wide and lengths of 10ft (3m), 20ft (6m), 40ft (12m), and 53ft in U.S. Schneider has unique solutions for sliding racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations of shipping containers Overhead cooling units (DX and CW) are available to maximize rack space 17 17

18 Module Enclosure Data Center Modular Room Overview Quickly add secure data centre rooms to a minimal finished building All wall panels, ceiling, and doors are pre-engineered to meet customer specs and delivered on-site for fast assembly All of the advantages of a modular build Scalable, simple design and deployment, and preserve Capex with the all of the flexibility of a traditional IT space Highly Secure Fire rated, Water-tight, Dust-tight Energy Efficient minimal thermal transmission losses Cleaner installation than traditional build no construction, conservation of materials Video Link 18 18

19 19 Smart Bunker Micro Data Center Self Sufficient Micro Datacenter in a Rack. Available in 23, 37 & 46Us configurations. Plug and play solution. Includes 100% DC infrastructure needed in a traditional server room. Prefabricated & offsite constructed - ready for production. Project simplification. High level of physical security. Anti ballistic & EMI protection optional. Indoor & outdoor deployment. Suitable for harsh environments Can be easily relocated and fits through doors. COOLING FIRE EXTINGUISING MONITORING UPS ACCESS INSULATION

20 20 Case Studies 20

21 21 Three Major Applications for Prefab Military, O&G, Remote deployments Service Providers and Large Scale Deployments Small & Medium Enterprises/DC Upgrades Challenges: Harsh environments International installations High Security Minimal local support for design/build/deploy Challenges: Grow data center capacity quickly Minimize CapEx through scalability Deploy in MWs Challenges: Lack of in-house design support Mitigate Risks Simplify my project Do I Buy or Build?

22 22 Case Studies Military, O&G, Remote deployments 22

23 Our Clients 23

24 Confidential Property of Schneider Electric 24 Military Customer - USA >Issue: >Military needed transportable C-130 solution built in US. >Military security specs, withstand harsh environment >Able to be disconnected within 7 hours >Solution: >5 x 20 ISO Containers >Entrance vestibule for clean air >2 IT Modules ganged to form single room >Power(225 KW N+1) >Chiller (60 tons N+1)

25 Confidential Property of Schneider Electric 25 Chevron Industrial/O&G > Issue: >Multiple sites with limited controls >Need consistent, repeatable design that can be deployed globally in different environments > Solution: >Multiple sites with same basic design >(3-5) ISO IT Containers with Integrated Chilled Water >(2) 500kW Power Modules >Chiller Skid & Generator Container

26 27 Case Studies Service Providers and Large Scale Deployments 27

27 Our Clients 28

28 Confidential Property of Schneider Electric 29 Vimpelcom, Russia Telco. DC Modular Rooms Issue > Need for a phased datacenter approach to preserve Capex. > Energy Efficiency as main objective > Data Center will support a new line of cloud services by Vimpelcom Solution > 6 DC Modular Rooms with a total power capacity of approx 7 MW of IT Power > Each Modular Room will host a1,2 MW of IT Power > Tier 3 design > Indirect Free Cooling (NFC*) as Source of Cooling aiming to work 98% of time a year with Free Cooling.

29 Confidential Property of Schneider Electric 30 Thor, Iceland Hosting and Cloud Storage Issue: > Growing service provider needed scalable solution to growth with their business > Geographically beneficial to use outside air for cooling Iceland Solution: > First Phase: One 40 IT Container with 17 indirect air economizer module on top (NFC), PUE 1.07 > Second Phase: Modular Data Center Room (assembled on site) with 50 indirect air economizer module on top (NFC).

30 Confidential Property of Schneider Electric 34 Capgemini, UK Service Provider Issue: > Global service provider needs to scale infrastructure with customer demand within large warehouse space > Needed flexible solution to expand in rack increments > Required air-economizer cooling limitations on PUE Solution: > Multi-Module system expandable up to 500kW > Indirect Air Economizer cooling > Cooling Modules installed inside building with mechanical heat rejection to air cooled chiller plant outside > Buss Bar Power distribution to the rack

31 35 Case Studies Enterprise Data Centers/DC Upgrades 35

32 Our Clients 36

33 Confidential Property of Schneider Electric 38 Nextel, Spain > Issue: > Challenging indoor parking lot location > Different IT loads per rack > Upgradable cooling and UPS capacity. > Potential Need to relocate. > Solution: >2x20 ISO. One for IT & One for Services >(8) 9kW/rack >(2) 50kW NFC cooling units >Vesda, Novec & CCTV >Optimize OPEX using NFC >Spend CAPEX as required

34 Confidential Property of Schneider Electric 39 Mackenzie Health - Health Care > Issue: >Growing hospital with a need for greater data center capacity with little available space >Data center is support not producing revenue. New building would cost too much >Need completed in 6 months > Solution: >11' x 55' Non-ISO All-in-one Module >Total Capacity 130kW > PX UPS, 12 racks, modular power, In-Row CW Cooling, Netbotz & DCIM software. >Chiller supplied by Contractor

35 40 Baidu, China DC Expansion Issue Facility ran out of white space had excess power and cooling. Baidu is testing Prefab concept for further expansions and sites Solution 160kW IT Module, located outside existing datacenter Prefab module will share the electrical infrastructure, generator and chilled with building. Module design includes Symmetra PX 250 UPS, InRow RC Gen 2, and Prisma panelboards.

36 41 Sagrada Familia, Barcelona > Objective >To support the construction process as well as ticketing and other key SF s processes. > Solution >2 Twin NON ISO 25 Prefabricated Datacenters All in One. >10 racks at 4KW/per rack and upgradable to 8KW /per rack. >Overhead fan coils cooling. UPS Symmetra PX, Netshelter Racks. > Why Schneider Electric? >Customization as winning factor >SE s ability to provide an upgradable and relocatable solution. >In-house Maintenance Capabilities & Services

37 42 Support 42

38 43 Where do I start? 1. Review planning and design tools 2. Work with local Sales and Prefab Specialists for preliminary budget and options Do I have local support? 3. Review Struxureware and Lifecycle Services for end-to-end solution 4. Yes! Local certified partner is ENEL PS d.o.o., supported by local and global teams. Confidential Property of Schneider Electric 43

39 44 Planning and Design Tools Prefabricated DC White Papers #163, 164, 165, 166 Trade-Off Tool - Cost Analysis of traditional vs Prefab hite%20paper&query_type= VTNR_R1_EN.swf?sdirect=true

40 Confidential Property of Schneider Electric 45 Planning and Design Tools Prefabricated Data Center Reference Designs > Library of engineered reference designs > 500kW, 1 MW, 2MW, 3.3MW and 20MW deployment sizes > Uptime Tier II and III designs > Semi and Fully prefabricated configurations > Design Methodology and Explanation > System level technical specifications - Available load, PUE, Density, Layout > Complete schematics and BOMs

41 46 Planning and Design Tools (2) 250 kw Power Modules (3) 250 kw Chillers (2) 240 kw, 22 rack IT Modules (1) 500 kw Hydronics Module Ex: Fully Prefabricated Data Center Reference Design # kw Tier II

42 Planning and Design Tools - Website 47

43 48 Planning and Design Tools Website contains pre-engineered designs and technical documentation Submittal Drawings Electrical and mechanical one-lines Individual Data Sheets on each module Manuals and Site Prep Guides Downloadable CAD files

44 49 Schneider has invested to make Prefabricated data centers mainstream 1. We have a team of solution architects utilizing tools that can clearly demonstrate advantages and disadvantages when comparing prefabrication vs stick built 2. Schneider has building blocks of various ratings, technologies, and form factors are available not just containers 3. We are able to deliver an entire custom solution with our holistic approach to plan, design, deploy and operate a prefabricated data center

45 Schedule a tour to one of our demo sites - Barcelona, Spain - St. Louis, US

46 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies or their respective owners. 51

Prefabricated Data Center Solutions: Coming of Age

Prefabricated Data Center Solutions: Coming of Age Prefabricated Data Center Solutions: Coming of Age Steven Carlini - Global Data Center Marketing Director April 2014 Schneider Electric 1 Schneider Electric 2 Your ability to compete relies on the design,

More information

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft. [Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL

More information

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

3300 kw, Tier 3, Chilled Water, 70,000 ft 2 [Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

Nominee: Prefabricated, Pre Assembled Data Centre Modules by Schneider Electric

Nominee: Prefabricated, Pre Assembled Data Centre Modules by Schneider Electric Nominee: Prefabricated, Pre Assembled Data Centre Modules by Schneider Electric Nomination title: Schneider Electric Prefabricated, Pre Assembled Data Centre Modules Schneider Electric has introduced a

More information

NON ISO Modular Datacenter

NON ISO Modular Datacenter NON ISO Modular Datacenter NON ISO MODULAR DATACENTER Benefits NON ISO Modular Data Center is a purpose-engineered and fully > Differed Capex. integrated datacenter system designed to offer organizations

More information

200 kw, Tier 3, Chilled Water, 5250 ft 2

200 kw, Tier 3, Chilled Water, 5250 ft 2 [eference Design 4] 200 kw, Tier 3, Chilled Water, 5250 ft 2 DESIGN OVEVIEW Data Center IT Capacity 200 kw Adaptable from 50 kw to 600 kw Target Availability Tier 3 Annualized UE at 100% Load 1.67 in Miami,

More information

Sept 29, Schneider Electric s Micro Data Center Solutions

Sept 29, Schneider Electric s Micro Data Center Solutions Sept 29, 2015 Schneider Electric s Micro Data Center Solutions Micro Data Center Solutions ..by 2018 Digital traffic is expanding annually by 23%+, creating the need to scale digital infrastructure Source:

More information

1008 kw, Tier 2, Chilled Water, ft 2

1008 kw, Tier 2, Chilled Water, ft 2 [eference Design 81] 1008 kw, Tier 2, hilled Water, 18115 ft 2 DESIGN OVEVIEW Data enter IT apacity 1008 kw Adaptable from 200 kw to 3024 kw Target Availability Tier 2 Annualized PUE at 100% Load 1.65

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

5.2 MW, Pod-based build, Chilled Water, ft 2

5.2 MW, Pod-based build, Chilled Water, ft 2 [Reference Design 65] 5.2 MW, Pod-based build, hilled Water, 85000 ft 2 DESIGN OVERVIEW Data enter apacity 5.2 MW Target Availability Tier III with 2N power distribution and less-redundant generator configuration

More information

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2 [Reference esign 62] 9.6 MW, Traditional IT and OC-compatible, Indirect Air Economizer, 16970 m 2 ESIGN OVERVIEW ata Center IT Capacity 9.6 MW Target Availability Tier III with 2N power distribution and

More information

Types of Prefabricated Modular Data Centers

Types of Prefabricated Modular Data Centers Types of Prefabricated Modular Data Centers White Paper 165 Revision 0 by Wendy Torell Executive summary Data center systems or subsystems that are preassembled in a factory are often described with terms

More information

Total Modular Data Centre Solutions

Total Modular Data Centre Solutions Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system

More information

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been

More information

Cannon T4 Modular Data Center (MDC)

Cannon T4 Modular Data Center (MDC) SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4

More information

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Rack Colocation Hosting.   Data Centre Solutions Expertly Engineered Rack Colocation Hosting www.workspace-technology.com Data Centre Solutions Expertly Engineered We are committed to ensuring the very best data centre environment for your business Rack Colocation Hosting

More information

Close-coupled cooling

Close-coupled cooling Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

APC by Schneider Electric Elite Data Centre Partner

APC by Schneider Electric Elite Data Centre Partner Data Centre Solutions...energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration

More information

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals Michael Gagnon Coolcentric October 13 2011 Data Center Trends Energy consumption in the Data Center (DC) 2006-61 billion

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

Investor day. November 17, IT business Laurent Vernerey Executive Vice President

Investor day. November 17, IT business Laurent Vernerey Executive Vice President Investor day November 17, 2010 IT business Laurent Vernerey Executive Vice President IT business strategic domain Centralized generation Residential Residential Industries Non Residential Transmission

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm

More information

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Data Centre Solutions.   Data Centre Solutions Expertly Engineered Data Centre Solutions www.workspace-technology.com Data Centre Solutions Expertly Engineered We will expertly deliver your data centre using our world-class skills and capabilities. Data Centre Solutions

More information

Datacenter Cooling. DC Cooling Efficiency and Project experience. Osman Uzuner. Vakıfbank Central Systems Management Datacenter Operations

Datacenter Cooling. DC Cooling Efficiency and Project experience. Osman Uzuner. Vakıfbank Central Systems Management Datacenter Operations Datacenter Cooling DC Cooling Efficiency and Project experience Osman Uzuner Vakıfbank Central Systems Management Datacenter Operations Agenda Agenda and Intro About Vakıfbank DC Energy Consumption breakdown

More information

APC APPLICATION NOTE #146

APC APPLICATION NOTE #146 #146 Hot Aisle Containment Application Guidelines and Approved Configurations By Kevin Lemke Abstract The Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating

More information

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency

More information

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Data Center Trends: How the Customer Drives Industry Advances and Design Development Bablu Kazi, PE MORRISON HERSHFIELD MISSION CRITICAL Data Center Trends: How the Customer Drives Industry Advances and Design Development What does the Customer Need? Scalability P U E Latest Technology

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are

More information

Reference Design Quicktour Design Summary

Reference Design Quicktour Design Summary Quicktour Design Summary Outdoor Heat Rejection Mixed Use or Purpose Built Data Center Facility Indoor/Outdoor Power Generation Mechanical Room Electrical Room Data Center Whitespace Reclaimed Whitespace

More information

One Stop Cooling Solution. Ben Tam Business Development Manager

One Stop Cooling Solution. Ben Tam Business Development Manager One Stop Cooling Solution Ben Tam Business Development Manager Agenda One Stop Cooling Solution Challenges Customers Are Facing Today Rack / Row / Room Solution Keynotes New Product Launch Slide 2 2 One

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design. TelecityGroup Kvastvägen 25-29 128 62 Sköndal Stockholm Sweden Tel: +46 (0) 8 799 3800 se.info@telecity.com www.telecitygroup.se

More information

Next Generation Cooling

Next Generation Cooling Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack

More information

DATA CENTER COLOCATION BUILD VS. BUY

DATA CENTER COLOCATION BUILD VS. BUY DATA CENTER COLOCATION BUILD VS. BUY Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for

More information

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited. Data Centre & Colocation in Birmingham Flexible. Secure. Accredited. Intercity - transforming your business Work Together. Work Anywhere. Work Securely. At Intercity Technology, we re driven by our people-first

More information

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient

More information

SmartMod Intelligent, Integrated Infrastructure for the Data Center

SmartMod Intelligent, Integrated Infrastructure for the Data Center SmartMod Intelligent, Integrated Infrastructure for the Data Center Deploy a High-Capacity, Efficient and Secure Infrastructure in Just Months Building a new data center in a short timeframe is nearly

More information

Datacentre Milton Keynes Data sheet

Datacentre Milton Keynes Data sheet Datacentre Milton Keynes Data sheet Data sheet Datacentre Milton Keynes Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the

More information

Welcome Association of Energy Engineers to the Microsoft Technology Center

Welcome Association of Energy Engineers to the Microsoft Technology Center Welcome Association of Energy Engineers to the Microsoft Technology Center Today s Agenda 10:00 10:30 What s new in data center energy efficiency planning and implementation? 10:30 11:00 ASHRAE data center

More information

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions

More information

Reducing Data Center Cooling Costs through Airflow Containment

Reducing Data Center Cooling Costs through Airflow Containment FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Datacentre Milton Keynes Hall C Data sheet

Datacentre Milton Keynes Hall C Data sheet Datacentre Milton Keynes Hall C Data sheet Data sheet Datacentre Milton Keynes Hall C Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant

More information

Datacentre Reading East 2 Data sheet

Datacentre Reading East 2 Data sheet Datacentre Reading East 2 Data sheet Data sheet Datacentre Reading East 2 Find us With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our datacentre locations, Pulsant has the

More information

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up Solutions For Business-Critical Continuity Deploy a Fully Configured Data Center in Just Weeks Efficiency. Capacity. Availability.

More information

Data Center Infrastructure Management (D.C.I.M.)

Data Center Infrastructure Management (D.C.I.M.) Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)

More information

Datacentre Newbridge Data sheet

Datacentre Newbridge Data sheet Datacentre Newbridge Data sheet Data sheet Datacentre Newbridge Find us 7 Claylands Road Edinburgh EH28 8LF Scotland With 10 datacentres, over 4,500 racks and a 10Gb resilient core network between our

More information

Constru January 15, 2013

Constru January 15, 2013 Use of Modula ar Design and its Relation to Energy Performance and Constru uction Costs January 15, 2013 The data center designerr and user now have a very wide range of modular options available with

More information

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy PLAYBOOK F O R C H A N G E How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy The world is becoming more digital every day. The demand for feature-rich,

More information

DATA CENTER LIQUID COOLING

DATA CENTER LIQUID COOLING DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid

More information

Data Centre In A Box

Data Centre In A Box Data Centre In A Box Data Centre In A Box Rittal s Data Centre In A Box replicates all of the key data centre capabilities but on a smaller scale. The Data Centre In A Box mitigates risk and provides compelling

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Impact of Air Containment Systems

Impact of Air Containment Systems White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical

More information

A next generation Colocation data centre for Birmingham city centre

A next generation Colocation data centre for Birmingham city centre A next generation Colocation data centre for Birmingham city centre Presenter: Russel Smith The Exponential Growth in Data BIG Data Social Networking Cloud Multi Media Device Apps SMART Cities High density,

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Close Coupled Cooling for Datacentres

Close Coupled Cooling for Datacentres Close Coupled Cooling for Datacentres Dr Fathi Tarada Mosen Ltd fathi.tarada@mosenltd.com www.mosenltd.com Agenda Increasing Power Densities Raised Floor Limitations Hot and Cold Aisle Enclosures Close

More information

Case Study Leicester City Council

Case Study Leicester City Council Data Centre Solutions...energy efficient by design Case Study Leicester City Council Leicester City Council Deploys New Sub 1.1 PUE3 Data Centre Infrastructure. Designed & Installed by Workspace Technology

More information

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling STULZ Micro DC with Chip-to-Atmosphere TM Liquid to Chip Cooling STULZ Micro DC Data center professionals and communication service providers (CSPs) face an increasingly difficult world. The continued

More information

M+W Group s Visionary Delta Datacenter

M+W Group s Visionary Delta Datacenter Region Central Europe M+W Germany GmbH A Company of the M+W Group 23 rd April 2014 M+W Group s Visionary Delta Datacenter IKS Data Center Design & Engineering Conference 2014 Moscow, Russia M+W Group at

More information

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Modular & Mobile Data Centre Solutions.     Data Centre Solutions Expertly Engineered Modular & Mobile Data Centre Solutions www.workspace-technology.com www.mobiledatacentre.com Data Centre Solutions Expertly Engineered ...providing clients with complete agility, delivering a scalable

More information

Customizable Colocation: Building for the Future

Customizable Colocation: Building for the Future Customizable Colocation: Building for the Future IronGate Data Centers meets the exact needs of customers with flexible Data Center Infrastructure solutions from Schneider Electric IronGate Data Centers

More information

18 th National Award for Excellence in Energy Management. July 27, 2017

18 th National Award for Excellence in Energy Management. July 27, 2017 18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months

More information

30 th September Always Right Size Modular Data Centres. Cannon Technologies Ltd (2015)

30 th September Always Right Size Modular Data Centres. Cannon Technologies Ltd (2015) 30 th September 2015 Glenn Conlon Always Right Size Modular Data Centres Traditional DC Build: Image courtesy of ENP Traditional DC: IRO 20 million + @ T2/3 Image courtesy of ENP DC Halls x 2, 500 Cabinets

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

Indirect Adiabatic and Evaporative Data Centre Cooling

Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group Make the most of your Energy from Power Plant to Plug Chris Simard, Regional Director Field Sales Group We see six key challenges facing our world Connectivity Simplicity Globalization Demand For Energy

More information

Liebert DCW CATALOGUE

Liebert DCW CATALOGUE Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers

More information

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Variable Density, Closed-Loop, Water-Cooled Data Center Solution Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of

More information

POWER AND THERMAL MANAGEMENT SOLUTIONS

POWER AND THERMAL MANAGEMENT SOLUTIONS POWER AND THERMAL MANAGEMENT SOLUTIONS Power has long been a critical public utility we depend on in our homes and daily lives. Companies are under pressure to provide the necessary hardware and software

More information

Indirect Adiabatic and Evaporative Data Center Cooling

Indirect Adiabatic and Evaporative Data Center Cooling Indirect Adiabatic and Evaporative Data Center Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced technology

More information

APC InfraStruXure Solution Overview

APC InfraStruXure Solution Overview APC InfraStruXure Solution Overview We re waiting for your call or email. 800--0 uptime@uptimeu.com Wiring Closets ( Racks) Small Server Rooms ( Racks) Small Data Centers ( 0 Racks) Medium Data Centers

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

HIGH DENSITY RACK COOLING CHOICES

HIGH DENSITY RACK COOLING CHOICES WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES

More information

Virtualization and consolidation

Virtualization and consolidation Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical

More information

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc. Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

ZTE ZXCR Series DX In-Row Air Conditioning Product Description ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase

More information

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions NREL Validates LCS Technology PRESENTED BY Herb Zien CEO, LiquidCool Solutions Learning Objectives As much as 40% of data center power is used to circulate air, and fans in a typical 30-megawatt data center

More information

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center SMARTAISLE Deploy an Efficient and Flexible Row-Based Infrastructure Efficiency. Capacity. Availability. Control. The SmartAisle infrastructure

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers The right-sized UPS for demanding business-critical applications The Schneider Electric Symmetra PX 96/160

More information

Making the impossible data center a reality.

Making the impossible data center a reality. United Nations ITU WSIS 2016 WINNER E-Environment Malaysia s First Win 2015 ASIA PACIFIC WINNER 2015 Best of Sustainability and Environmental Technology WINNER 2015 Best of Sustainability and Environmental

More information

Continuity Insights Chicago: Evolving Data Center Trends & Design Standards. 19 June Jose Hernandez, 30+ years of design/build experience

Continuity Insights Chicago: Evolving Data Center Trends & Design Standards. 19 June Jose Hernandez, 30+ years of design/build experience Continuity Insights Chicago: Evolving Data Center Trends & Design Standards Technology Management, Inc. 1911 Rohlwing Rd., Suite E Rolling Meadows, IL 60008 847 394 8900 19 June 2013 www.tmiamerica.com

More information

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Evaporative free air cooling technology Providing evaporative free air cooling solutions. Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free

More information

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center Deploy a Fully Configured Data Center in Just Weeks Availability, Capacity, Efficiency. You need them and now you can have them

More information

Huangcun IDC of China Unicom Beijing: China's First Warehouse Micro-modular IDC

Huangcun IDC of China Unicom Beijing: China's First Warehouse Micro-modular IDC Huangcun IDC of China Unicom Beijing: China's First Warehouse Micro-modular IDC China Unicom Beijing (hereinafter referred to as Beijing Unicom below) has reconstructed its two unused warehouses in Huangcun,

More information

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC Planning for Liquid Cooling -------------------------------- Patrick McGinn Product Manager, Rack DCLC February 3 rd, 2015 Expertise, Innovation & Delivery 13 years in the making with a 1800% growth rate

More information

DC Energy, Efficiency Challenges

DC Energy, Efficiency Challenges DC Energy, Efficiency Challenges Choosing a density strategy Implementing a high density environment Maximizing the efficiency benefit Anticipating the dynamic data center Key points on energy usage in

More information