Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

Size: px
Start display at page:

Download "Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products"

Transcription

1 Data Center Temperature Design Tutorial Ian Seaton Chatsworth Products

2 What are we going to do today? Explore a process for determining what data center operating temperature will deliver the best total cost of ownership, while meeting uptime and reliability objectives, for a wide range of boundary variables

3 What are we going to do today? Background of ASHRAE environmental guidelines for data centers Difference between comfort cooling and data center cooling Minimum best practices Considerations for a design without cooling economization Considerations for a design with cooling economization Considerations for a design without mechanical cooling How to weigh impact of design elements on computer equipment reliability and availability BREAK

4 What are we going to do today? Quiz Design element assessment practice exercise Special considerations for a building retrofit project Special considerations for an efficiency upgrade project Summary/review

5 Learning Objectives You will understand how to integrate ASHRAE TCO guidelines into a building design project. You will be able to articulate the differences between comfort cooling and data center cooling. You will be able to apply the different data center class temperature thresholds to the process of evaluating relative merits of competing design concepts. You will be able to de-couple inherent power usage effectiveness (PUE) errors from total building energy use estimates. You will be able to calculate the impact on computer equipment reliability of specific building design strategies.

6 Appendix C Detailed Flowchart for the Use and Application of the ASHRAE Data Center Classes ANSI/BICSI Data Center Design and Implementation Best Practices Appendix G Design for Energy Efficiency

7

8 2015 Update Thermal Guidelines for Data Processing Equipment, ASHRAE, 2012

9 Dry Bulb Temperatures Server Classes Recommended Allowable A to to 89.6 A to to 95 A to to 104 A to to 113

10

11 Let s Get Started Desire to Reduce TCO and Explore Higher Temperatures My data center project is? New Construction Major Retrofit Existing, looking for Efficiency Gains

12 NOTES FOR APPENDIX C FLOW CHARTS 1. To use the highest inlet temperatures, ensure excellent airflow segregation is in place to avoid recirculation with warmer IT outlet flows. 2. Higher temperature IT loses its primary benefit if mixed with standard IT equipment, a common cooling system must meet the most demanding IT equipment requirements. 3. Ensure no chiller option choice meets availability requirements of the IT workload needs; investigate site extreme temperature and humidity conditions and economizer uptime risk. 4. Ensure the operational and safety aspects of high hot-aisle temperatures are understood; temperature of 140⁰F to 160⁰F may be expected. 5. Ensure higher airflow for IT equipment above the recommended range is understood. Data center airflow may have to increase dramatically.

13 New Construction Include best practices: airflow management, containment, VFD, control cooling at IT inlet Will you have an economizer? No Yes

14 Economizer? No Note 1 Operate data center within recommended environmental range at IT inlet. Investigate warmer chilled water temperature. Procure Class A1 or A2 ITE going forward

15 NOTES FOR APPENDIX C FLOW CHARTS 1. To use the highest inlet temperatures, ensure excellent airflow segregation is in place to avoid recirculation with warmer IT outlet flows. 2. Higher temperature IT loses its primary benefit if mixed with standard IT equipment, a common cooling system must meet the most demanding IT equipment requirements. 3. Ensure no chiller option choice meets availability requirements of the IT workload needs; investigate site extreme temperature and humidity conditions and economizer uptime risk. 4. Ensure the operational and safety aspects of high hot-aisle temperatures are understood; temperature of 140⁰F to 160⁰F may be expected. 5. Ensure higher airflow for IT equipment above the recommended range is understood. Data center airflow may have to increase dramatically.

16 Maximize Airflow Segregation Maximize Airflow Segregation When: T i max = TSLA Then: T i min - 10⁰F = LWT

17 Maximize Airflow Segregation

18 Economizer? No Note 1 Operate data center within recommended environmental range at IT inlet. Investigate warmer chilled water temperature. Procure Class A1 or A2 ITE going forward?

19 Where to procure Class A1 Servers? Where to procure Class A1 servers?

20 Economizer? No Note 1 Operate data center within recommended environmental range at IT inlet. Investigate warmer chilled water temperature. Assess accelerating technology refresh

21 Chiller Efficiency at Higher Set Points Why T i min is so important Chart from ASHRAE Data Center Design and Operation Book#6: Best Practices for Datacom Facility Energy Efficiency

22 With economizer Will you have an economizer? No Yes 1. Do detailed TCO analysis considering hours of economization at various Ti (including added cost of A3/A4 servers and increased energy use at higher Ti 2. Evaluate acceptable reliability of higher Ti 3. Assess impact of Class A3/A4 servers 4. Define optimum Tmax

23 Yes, with Economizer

24 TCO Worksheet, with economizer Sample Scenario Label Total 500kW IT load with 100 average 5kW each, in 5 rows of 20 cabinets each. Seven 30 ton N+2 redundancy, on slab floor with chimney cabinets

25 TCO Analysis Steps 1.Obtain relevant outdoor temperature bin data 2.Determine (estimate) total sensible cooling load 3.Obtain economizer operating cost estimate 4.Determine cost of expediting technology refresh from legacy Class A2 servers and cost between A3 and A4 servers

26 Outdoor Ambient Operating Conditions limatedata.html Content/Tools/NAmericanFreeCooling Tool

27 Water-Side Economization Parallel Economizer On or Off (may limit free cooling hours) Simple pump control Dead band increases approach temperature Should be controlled by engineer Easier retrofit Better ROI for larger data centers Long, cold winter Series Economizer Partial economization adds free cooling Complex pump control Approach figured on return temperature Can be controlled by automation More complex retrofit Better ROI for smaller data centers Temperate climate

28 Affinity Law Fan Energy Economies 10 CRAH units with 12 Hp fan motors 797, % rpm 581,130 90% rpm 408,146 80% rpm 273,426 70% rpm

29 Affinity Law Fan Energy Economies 2 MW data center case study example, N+2 CRAH redundancy $290,765 to operate 44 94% fan rpm $42,075 to operate 44 49% fan rpm $141,417 to operate 24 90% rpm $500,000 capital expense avoidance Year One $1,390, CRAHs and no containment $1,142, CRAHs and containment $741, CRAHs and containment

30 Affinity Law Fan Energy Economies 2 MW data center case study example, N+2 CRAH redundancy $290,765 to operate 44 94% fan rpm $42,075 to operate 44 49% fan rpm $141,417 to operate 24 90% rpm $500,000 capital expense avoidance Year Five $2,553, CRAHs and no containment $1,307, CRAHs and containment $1,307, CRAHs and containment

31 Affinity Law Fan Energy Economies 2 MW data center case study example, N+2 CRAH redundancy $290,765 to operate 44 94% fan rpm $42,075 to operate 44 49% fan rpm $141,417 to operate 24 90% rpm $500,000 capital expense avoidance Year Ten $4,087, CRAHs and no containment $1,518, CRAHs and containment $2,014, CRAHs and containment

32 Energy Use in Data Centers IT Energy (UPS Load) Cooling equipment Power Conversion Lighting

33 Cooling Requirements in Data Centers IT Load Electrical room Battery room Power substation CRAC/CRAH fan motors Power Conversion Losses Lighting Make-up air Pump motors Bypass air Building and room skin losses

34 Energy Use in Data Centers

35 Determine Sensible Cooling Load

36 Forecast the Life of the Data Center Source: Datacom Equipment Power Trends and Cooling Applications, 2 nd edition, ASHRAE, 2012, Table 4.1 Volume Server Power Trends

37 Apply Power Trends to Plan How many technology refreshes is the data center being planned to see? How much expected application growth? Plot refresh growth from point on the trend curves where you are today. Determine how much of the forecasted load to include in initial capacity.

38 Using CFD to fine-tune TCO Analysis 64% airflow volume < 1.5% over-supply Higher supply air temperature

39 Using CFD to fine-tune TCO Analysis All server inlet temperatures are within recommended environmental envelope

40 Server Airflow versus Temperature 1.4 = 40% increase in airflow 40% increase in airflow = 274% increase in fan energy (1.4 3 = 2.74) Example 700 watt server with 70 watts for fan 68 Fan energy increased to Thermal Guidelines for Data Processing Environments, Fourth Edition, ASHRAE Total server energy increased from 700 to

41 Server Airflow versus Temperature Example Implications 500 servers = 840,000 kw hours hours = 1.5 million kw hours avoidance 4 ½ year = 750,000 kw hours avoidance Realistic scenario 10% of year running CRACs when ambient exceeds 86 50% of year running no CRACs % of year running no CRACs below 68

42 Server Airflow versus Temperature Convection heat transfer from a surface to an airflow is governed by the equation q = ha(t w T f ) Where q = the heat transfer rate h = the convection heat transfer coefficient A = the surface area T w = the temperature of the surface T f = the temperature of the fluid Sensible cooling CFM = 3.1W ΔT Where CFM = cubic feet per minute airflow w = watts (sensible heat load) ΔT = temperature rise in ⁰F

43 Server Airflow versus Temperature Hewlett-Packard research project reported at 2011 Uptime Symposium Server Inlet Total Energy Temperature Cost _ PUE 68⁰F $ ⁰F $ ⁰F $ ⁰F $

44 Thermal Guidelines for Data Processing Environments, Fourth Edition, ASHRAE Server Airflow versus Temperature

45 Server Airflow versus Temperature Hypothetical Illustrative Example One Megawatt data center watt servers A3 95 F = 8% fan energy penalty (or watts) Build new data center in Seattle

46 Server Airflow versus Temperature Seattle Illustrative Example with A3 Servers 3 hours a year at or above 96 3 hours a year right at 95 3 hours a year at hours a year at hours a year at hours a year at hours a year at hours at 68 F or lower

47 Server Airflow versus Temperature 3 hours on chiller = 0 penalty 3 8% $.10 per kw/h = $0.24 penalty 3 5% $.10 per kw/h = $0.15 penalty % $.10 per kw/h = $0.85 penalty % $.10 per kw/h = $2.57 penalty 220 1% $.10 per kw/h = $2.22 penalty 442 $.10 per kw/h = $2.27 penalty $.10 per kw/h = $0 penalty Total fan energy penalty for Class A3 servers in 1MW Seattle data center = $8.25

48 Server Airflow versus Temperature WITH ALLOWABLE MAXIMUM SERVER INLET OF 95 Total energy savings for 8757 hours without a chiller = $195, : 200% up to 700% 5 year ROI 33 to 83 week payback 2015 and following: 2.4 million % 1 year ROI 22 minute payback

49 Server Airflow versus Temperature San Antonio Illustrative Example with A3 Servers 9 hours a year at or above 96 4 hours a year right at hours a year at hours a year at hours a year at hours a year at hours a year at hours at 68 F or lower

50 Server Airflow versus Temperature 9 hours on chiller = 0 penalty 4 8% $.10 per kw/h = $3.20 penalty 161 5% $.10 per kw/h = $80.50 penalty % $.10 per kw/h = $ penalty % $.10 per kw/h = $ penalty % $.10 per kw/h = $ penalty $.10 per kw/h = $84.60 penalty $.10 per kw/h = $0 penalty Total fan energy penalty for Class A3 servers in 1MW San Antonio data center = $805.30

51 Server Airflow versus Temperature WITH ALLOWABLE MAXIMUM SERVER INLET OF 95 Total energy savings for 8751 hours without a chiller = $195, : 200% up to 650% 5 year ROI 34 to 84 week payback 2015 and following: 24,134% 1 year ROI 1.5 day payback

52 Cooling Cost Roll-up, example 12kW to operate 5 cooling 64% capacity 41.8kW to operate 65 F H 2 O leaving temperature 0.06 kw for fresh air (N+1) 0.56kW for electrical room (N+1) 0.06kW for battery room (N+1) 15kW for substation (N+1, but not simultaneously running redundancy 608,119 kw hours per year $58,800 cooling budget at $0.10 per kw hour (.23 ANNUALIZED MECHANICAL LOAD COMPONENT)

53 TCO Calculation

54 TCO Calculation

55 TCO Calculation

56 The Big Worry: How to know the effect of temperature on ICT equipment reliability/life? How to know how long it is OK to operate in allowable temperature range? The X Factor 1. Baseline = 24/7 68 F server inlet temperature 2. OEM historical data on user failure reports 3. Performance variations above, at and below baseline Premise is that the data center temperature follows mother nature

57 Evaluate acceptable reliability of higher Inlet Temperatures T i Failure Rate x-factor (⁰F) Lower Bound Average Bound Upper Bound Thermal Guidelines for Data Processing Environments, Fourth Edition, ASHRAE TC9.9

58 Implications of X - Factor If 1000 servers produced 30 failures during warranty period (3% failure rate) running all year at 68⁰F, then those servers would produce 44 failures running all 90⁰F inlet temperature BUT 438 hours below 59⁰F 876 hours at 59⁰F F ⁰F ⁰ ⁰F ⁰F Results in 29 failures, or one fewer than running all 68⁰F

59 Implications of X - Factor Thermal Guidelines for Data Processing Environments, Fourth Edition, ASHRAE TC9.9

60 Evaluate acceptable reliability of higher Inlet Temperatures Time at temperature weighted failure rate calculations for IT equipment in Chicago Inlet Temperature The X factor % of Hours 59⁰F T 68⁰F ⁰F T 77⁰F ⁰F T 86⁰F ⁰F T 95⁰F % 17.2% 10.6% 4.6% 2011Thermal Guidelines for Data Processing Environments Expanded Data Center Classes and Usage Guidance, White Paper, ASHRAE TC9.9 Net x-factor = 0.99

61 TCO Preliminary Results Analysis shows positive returns? No Yes No Will you have a chiller? Yes Operate data center within recommended environmental range at IT inlet. Investigate warmer chilled water temperature. Procure Class A1 or A2 ITE Think Technology Refresh

62 Economizer with Chiller Notes 4,5 Yes Set economizer to provide free cooling from 59⁰F to lowest TCO Tmax, select ITE for Ti as: A1: 90⁰F A2: 95⁰F A3: 104⁰F A4: 113⁰F Ensure all data center components capable of meeting ASHRAE Class

63 NOTES FOR APPENDIX C FLOW CHARTS 1. To use the highest inlet temperatures, ensure excellent airflow segregation is in place to avoid recirculation with warmer IT outlet flows. 2. Higher temperature IT loses its primary benefit if mixed with standard IT equipment, a common cooling system must meet the most demanding IT equipment requirements. 3. Ensure no chiller option choice meets availability requirements of the IT workload needs; investigate site extreme temperature and humidity conditions and economizer uptime risk. 4. Ensure the operational and safety aspects of high hot-aisle temperatures are understood; temperature of 140⁰F to 160⁰F may be expected. 5. Ensure higher airflow for IT equipment above the recommended range is understood. Data center airflow may have to increase dramatically.

64 CRAC/CRAH Selection Cooling capacity requirement (growth + redundancy) Efficiency (EER/SEER or COP) CRAH-1w/EC EER = 58 CRAH-2wEC EER = 133 CRAH-3 centrifugal EER = 43 Close-Coupled EER = 38 CRAC-1 EER = 14 CRAC-2 EER = 11 kw per ton Chiller New Chiller Existing Reciprocating.78 to to 1.2 or higher Screw.62 to to.85 or higher Centrifugal High.50 to.62 NA Centrifugal Moderate.63 to to.80 or higher CRAC (DX) 1.0 to to 2.5 or higher Free-cooling opportunities

65 Economizer with Chiller Notes 4,5 Yes Set economizer to provide free cooling from 59⁰F to lowest TCO Tmax, select ITE for Ti as: A1: 90⁰F A2: 95⁰F A3: 104⁰F A4: 113⁰F Ensure all data center components capable of meeting ASHRAE Class

66 Annual Hours of Operation with Mechanical Cooling and Class A2 Servers Recommended inlet temperatures Class A2 allowable inlet temperatures Economizer with Data Center Containment HA/CA Water-Side Wheel Air-Side IEC Chicago 70% 14.6% 14.6% 12.7% 10.2% 70% 0% 0.2% 0% 0% Seattle 92.5% 4% 2.9% 2.4% 0% 92.5% 0% 0.1% 0% 0% San Antonio 98% 58.4% 36.5% 33.4% 42.2% 98% 0.9% 1% 0.1% 18.6% Denver 71.9% 6.8% 13% 12% 22.2% 71.9% 0% 2% 0.7% 0%

67 Annual Hours of Operation with Mechanical Cooling and A3 Servers Recommended inlet temperatures Class A3 allowable inlet temperatures Economizer with Data Center Containment HA/CA Water-Side Wheel Air-Side IEC Chicago 70% 14.6% 14.6% 12.7% 10.2% 70% 0% 0% 0% 0% Seattle 92.5% 4% 2.9% 2.4% 0% 92.5% 0% 0% 0% 0% San Antonio 98% 58.4% 36.5% 33.4% 42.2% 98% 0.6% 0% 0% 0.6% Denver 71.9% 6.8% 13% 12% 22.2% 71.9% 0% 0% 0% 0%

68 Economizer without Chiller Notes 3,4,5 No Set economizer to provide free cooling from 59⁰F to maximum annual outdoor temperature, select ITE for Ti as: A1: 90⁰F A2: 95⁰F A3: 104⁰F A4: 113⁰F Ensure all data center components capable of meeting ASHRAE Class

69 NOTES FOR APPENDIX C FLOW CHARTS 1. To use the highest inlet temperatures, ensure excellent airflow segregation is in place to avoid recirculation with warmer IT outlet flows. 2. Higher temperature IT loses its primary benefit if mixed with standard IT equipment, a common cooling system must meet the most demanding IT equipment requirements. 3. Ensure no chiller option choice meets availability requirements of the IT workload needs; investigate site extreme temperature and humidity conditions and economizer uptime risk. 4. Ensure the operational and safety aspects of high hot-aisle temperatures are understood; temperature of 140⁰F to 160⁰F may be expected. 5. Ensure higher airflow for IT equipment above the recommended range is understood. Data center airflow may have to increase dramatically.

70 Economizer without Chiller Notes 3,4,5 No Set economizer to provide free cooling from 59⁰F to maximum annual outdoor temperature, select ITE for Ti as: A1: 90⁰F A2: 95⁰F A3: 104⁰F A4: 113⁰F Ensure all data center components capable of meeting ASHRAE Class

71 Final Note No single design concept is best for all situations Well executed airflow management is the foundation for everything Newer ICT equipment opens more design options Free cooling does not necessarily mean exposure to outside elements ICT procurement/specification decisions affect mechanical design and performance Mechanical design decisions affect ICT deployment Consider EVERYTHING while you are still in design phase

72 10 MINUTE BREAK

73

74 QUICK REVIEW

75 What do you remember from before the break? What are the differences between comfort cooling and data center cooling?

76 What do you remember from before the break? What are the ASHRAE recommended temperature thresholds?

77 What do you remember from before the break? What are the ASHRAE allowable temperature thresholds for class A3 servers?

78 What do you remember from before the break? Where can you buy Class A1 servers today?

79 What do you remember from before the break? How can your PUE go down and your operating costs actually increase for doing the same amount of work?

80 What do you remember from before the break? How do you determine if your PUE anomaly is actually a serious issue?

81 What do you remember from before the break? What might make a Q factor of 1.3 acceptable?

82 Let s apply that 1. Open file: BICSI Practice Exercise w-omaha data.xls from the provided USB device 2. Go to the Input tab 3. Enter data only in yellow shaded cells 4. N.B.: Only ONE approach temperature (not both wet and dry) 5. Use AFM factor (airflow management) on card provided 6. You can pick maximum server inlet temperature, class of servers, and type of economization

83 Why We re not Examining Class A1 Servers Today Class A1 Sever Chart shows fan airflow Each point is an airflow that needs to be cubed to get energy 95 F is or 564% 40 watts X 564% = watts 400 watts 40 watts watts = watts 2500 servers = 1464KW total server energy = 464kW server fan energy penalty

84 Why We re Examining Class A2 and A3 Servers Today Class A2 and A3 charts show actual server energy Each point is a total server energy variation 95 F = or 112.5% 400 watts X 112.5% = 450 watts 2500 servers X 450 watts = 1125kW total server energy = 125kW server fan penalty

85 Let s apply that 1. Open file: Omaha BICSI Practice Exercise.xls from the provided USB device 2. Go to the Input tab 3. Enter data only in yellow shaded cells 4. N.B.: Only ONE approach temperature (not both wet and dry) 5. Use AFM factor (airflow management) on card provided 6. You can pick maximum server inlet temperature, class of servers, and type of economization 7. Enter server failure experience 8. Enter actual server inlet temperature experience 9. Short report on findings

86 Let s apply that Points of reference: 2.0 PUE = 8,760,000 kw hours for cooling energy 1.5 PUE = 3,504,000 kw hours for cooling energy 1.25 PUE = 1,314,000 kw hours for cooling energy WRITE THAT DOWN!!!

87 Let s apply that GO TO WORK WHAT DID YOU DISCOVER?

88 The Rest of the Story Desire to Reduce TCO and Explore Higher Temperatures My data center project is? New Construction Major Retrofit Existing, looking for Efficiency Gains

89 Major Retrofit Include best practices: airflow management, containment, VFD, control cooling at IT inlet Yes Do you have or are you adding an economizer? Is the new space thermally and airflow segregated from existing IT? Yes No No

90 With Economizer and Segregated New Space Yes 1. Do detailed TCO analysis considering hours of economization at various Ti (including added cost of A3/A4 servers and increased energy use at higher Ti 2. Evaluate acceptable reliability of higher Ti 3. Assess impact of Class A3/A4 servers 4. Define optimum Tmax No Analysis shows positive returns? Yes Will you have a chiller? Yes No

91 With Economizer and Segregated New Space Segregated high density space with cold aisle containment and partitioned return air space

92 Desire to Reduce TCO and Explore Higher Temperatures My data center project is? New Construction Major Retrofit Existing, looking for Efficiency Gains

93 Existing Data Center, Looking for Efficiency Gains Include best practices: airflow management, containment, VFD, control cooling at IT inlet Implement best practices for airflow management, hot/cold aisle, containment, blanking panels, correct airflows, VFDs (see BICSI , ASHRAE Datacom book series and EU CoC best practices No Do you have good airflow mgt? Rack Cooling Index & Return Temp. Index? Yes

94 Rack Index Over Temperature Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI), Magnus Herrlin, ASHRAE Transactions, Volume 111, Part 2 (DE )

95 Rack Index Under Temperature Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI), Magnus Herrlin, ASHRAE Transactions, Volume 111, Part 2 (DE )

96 Rack Index Under Temperature Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI), Magnus Herrlin, ASHRAE Transactions, Volume 111, Part 2 (DE ) Ian s suggestion for an improvement target: Set your minimum recommended temperature within 3⁰F of your maximum recommended temperature and then set your minimum allowable temperature 1-2⁰F below your minimum recommended temperature and set 100% as your project target

97 Existing Data Center, Looking for Efficiency Gains With Effective Airflow Management Yes Correct control strategy No Do you measure/ control IT inlet temperature? Yes Do you have an economizer? No Yes

98 NOTES FOR APPENDIX C FLOW CHARTS 1. To use the highest inlet temperatures, ensure excellent airflow segregation is in place to avoid recirculation with warmer IT outlet flows. 2. Higher temperature IT loses its primary benefit if mixed with standard IT equipment, a common cooling system must meet the most demanding IT equipment requirements. 3. Ensure no chiller option choice meets availability requirements of the IT workload needs; investigate site extreme temperature and humidity conditions and economizer uptime risk. 4. Ensure the operational and safety aspects of high hot-aisle temperatures are understood; temperature of 140⁰F to 160⁰F may be expected. 5. Ensure higher airflow for IT equipment above the recommended range is understood. Data center airflow may have to increase dramatically.

99 Final Note No single design concept is best for all situations Well executed airflow management is the foundation for everything Newer ICT equipment opens more design options Free cooling does not necessarily mean exposure to outside elements ICT procurement/specification decisions affect mechanical design and performance Mechanical design decisions affect ICT deployment Consider EVERYTHING while you are still in design phase

100 QUESTIONS? Ian Seaton Chatsworth Products, Inc. (512)

Recapture Capacity for Existing. and Airflow Optimization

Recapture Capacity for Existing. and Airflow Optimization Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities

More information

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Data Center Energy Savings By the numbers

Data Center Energy Savings By the numbers Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained

More information

Reducing Data Center Cooling Costs through Airflow Containment

Reducing Data Center Cooling Costs through Airflow Containment FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

Introducing the Heat Wheel to the Data Center

Introducing the Heat Wheel to the Data Center Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell

More information

Impact of Air Containment Systems

Impact of Air Containment Systems White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical

More information

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more

More information

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP This case study will evaluate the feasibility of data center free cooling in the Middle East using indirect

More information

18 th National Award for Excellence in Energy Management. July 27, 2017

18 th National Award for Excellence in Energy Management. July 27, 2017 18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months

More information

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Variable Density, Closed-Loop, Water-Cooled Data Center Solution Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of

More information

DCIM Data Center Infrastructure Management Measurement is the first step

DCIM Data Center Infrastructure Management Measurement is the first step DCIM Data Center Infrastructure Management Measurement is the first step Presented by Julius Neudorfer Sponsored by DCIM Data Center Infrastructure Management Measurement is the first step Presented by

More information

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant

More information

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings WHITE PAPER AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc.

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment

More information

A Green Approach. Thermal

A Green Approach. Thermal A Green Approach to Thermal Management Thermal Management - AGENDA Definitions & Thermal Facts Density Trends Rack Level Management Passive Solutions Thermal Sources & Green Solutions Data Center Layout

More information

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit Hot vs Cold Energy Efficient Data Centers - SVLG Data Center Center Efficiency Summit KC Mares November 2014 The Great Debate about Hardware Inlet Temperature Feb 2003: RMI report on high-performance data

More information

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Reducing Energy Consumption with

Reducing Energy Consumption with Reducing Energy Consumption with Passive Cooling Ian Cathcart, RCDD Technical Support Manager Technical Support Manager Chatsworth Products, Inc. Thermal Management: Mission Critical Data center heat loads

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency

More information

Data Center Energy and Cost Saving Evaluation

Data Center Energy and Cost Saving Evaluation Available online at www.sciencedirect.com ScienceDirect Energy Procedia 75 (2015 ) 1255 1260 The 7 th International Conference on Applied Energy ICAE2015 Data Center Energy and Cost Saving Evaluation Z.

More information

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data White Paper EC9005A Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data Peer reviewed case study data from ASHRAE now updated with CFD model analysis revealing

More information

Virtualization and consolidation

Virtualization and consolidation Virtualization and consolidation Choosing a density strategy Implementing a high-density environment Maximizing the efficiency benefit Anticipating the dynamic data center Schneider Electric 1 Topical

More information

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Optimization in Data Centres Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering Outline Background and Motivation Overview and scale of data

More information

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located

More information

Optimiz Chilled January 25, 2013

Optimiz Chilled January 25, 2013 Optimiz zing Existing Data Center Chilled Water Plants January 25, 2013 This White Paper describes factors to be consideredd when optimizing an existing data center chilledd water plant. Authored by Michael

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Evaporative free air cooling technology Providing evaporative free air cooling solutions. Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free

More information

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. :: In a recent Uptime Institute survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. 2 Maintain Assess Control ROI Monitor Optimize The Need for a Better Approach

More information

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt

More information

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are

More information

Welcome Association of Energy Engineers to the Microsoft Technology Center

Welcome Association of Energy Engineers to the Microsoft Technology Center Welcome Association of Energy Engineers to the Microsoft Technology Center Today s Agenda 10:00 10:30 What s new in data center energy efficiency planning and implementation? 10:30 11:00 ASHRAE data center

More information

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project Cisco Lab Setpoint Increase Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify key technology, policy and

More information

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach Proper airfl ow and thermal management are the most critical aspects of designing and operating your data center,

More information

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Data Center Trends: How the Customer Drives Industry Advances and Design Development Bablu Kazi, PE MORRISON HERSHFIELD MISSION CRITICAL Data Center Trends: How the Customer Drives Industry Advances and Design Development What does the Customer Need? Scalability P U E Latest Technology

More information

Cooling Solutions & Considerations for High Performance Computers

Cooling Solutions & Considerations for High Performance Computers Cooling Solutions & Considerations for High Performance Computers White Paper 6 Revision 1 By Rich Whitmore Executive summary The recent advances in high performance computing have driven innovations not

More information

The Energy. David L. Moss Dell Data Center Infrastructure

The Energy. David L. Moss Dell Data Center Infrastructure The Energy Advantages of Containment Systems David L. Moss Dell Data Center Infrastructure www.dell.com/hiddendatacenter Summary The Uptime Institute estimates that the cost to build a new 20,000 square

More information

Data Center Trends and Challenges

Data Center Trends and Challenges Data Center Trends and Challenges, IBM Fellow Chief Engineer - Data Center Energy Efficiency Customers challenges are driven by the following Increasing IT demand Continued cost pressure Responsive to

More information

Planning a Green Datacenter

Planning a Green Datacenter Planning a Green Datacenter Dr. Dominique Singy Contribution to: Green IT Crash Course Organisator: Green IT Special Interest Group of the Swiss Informatics Society ETH-Zurich / February 13, Green Data

More information

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 APC InRow Cooler Prototype Initial Report - Test Setup Verification H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 1 Introduction Contents Technology Description/Attributes Installation

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

Rittal Cooling Solutions A. Tropp

Rittal Cooling Solutions A. Tropp 1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

Air Containment Design Choices and Considerations

Air Containment Design Choices and Considerations Air Containment Design Choices and Considerations Brad J. Murphy, A.Sc.T., ATS, DCDC, DCEP, Principal Racon Data Centres Introduction Introduction Air containment design must consider many different factors

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent

More information

Optimizing Cooling Performance Of a Data Center

Optimizing Cooling Performance Of a Data Center ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,

More information

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and

More information

Google s Green Data Centers: Network POP Case Study

Google s Green Data Centers: Network POP Case Study Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice

More information

Next Generation Cooling

Next Generation Cooling Next Generation Cooling Server Manufacturer Perspective Practical and Cost Effective David Moss Data Center Strategist Dell 1 Why Chip, Row, or Rack? Density? Energy Don t be scared; I don t see 50kW/rack

More information

Case study: Energy efficiency improvements in a legacy data centre. Robert Tozer Director Opera>onal Intelligence

Case study: Energy efficiency improvements in a legacy data centre. Robert Tozer Director Opera>onal Intelligence Case study: Energy efficiency improvements in a legacy data centre Robert Tozer Director Opera>onal Intelligence Objec>ves First improve air management Air supply temperature to servers Lower temperature

More information

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009 The End of Redundancy Alan Wood Sun Microsystems May 8, 2009 Growing Demand, Shrinking Resources By 2008, 50% of current data centers will have insufficient power and cooling capacity to meet the demands

More information

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group Data center cooling evolution. The hottest way to save energy Lucio Bustaffa: Product Development Manager BlueBox Group Data Center overview What s happening in the web? 2 Data Center overview What s happening

More information

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for: REPORT Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD Prepared for: San Diego Supercomputer Center 10100 John J Hopkins Drive San Diego, CA 92037 May 11, 2009

More information

IT Air Conditioning Units

IT Air Conditioning Units IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered Survey and Audit Service Schedule Airflow and Thermal Imaging Survey Service Schedule Data Centre Solutions Expertly Engineered Consult optimisation, audit and survey services Data Centre Services Workspace

More information

Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation

Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation A cost model (See figure 1) has been created to provide the user a simplified method for directly comparing the energy cost of a

More information

Retro-Commissioning Report

Retro-Commissioning Report 10 Retro-Commissioning Report Retro-Commissioning Retro-Commissioning is the process for identifying intrinsic operational and energy related issues in the facilities DDC system and providing a mechanism

More information

Green IT Project: The Business Case

Green IT Project: The Business Case Green IT Project: The Business Case Indumathi Lnu University at Albany DATE We will discuss Identifying green IT projects Funding green IT projects Building the business case Case study: University at

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

MEASURE MONITOR UNDERSTAND

MEASURE MONITOR UNDERSTAND MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration

More information

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Effectiveness and Implementation of Modular Containment in Existing Data Centers WHITE PAPER Effectiveness and Implementation of Modular Containment in Existing Data Centers By Lars Strong, P.E., Upsite Technologies, Inc. Bruce Long, Upsite Technologies, Inc. 505.798.0200 upsite.com

More information

Power & Cooling Considerations for Virtualized Environments

Power & Cooling Considerations for Virtualized Environments Power & Cooling Considerations for Virtualized Environments Cisco Data Center Day 2008 31-01-2008 APC-MGE Vision & Mission OUR VISION APC-MGE products ensure availability wherever data is created, transmitted

More information

Scalable, Secure. Jason Rylands

Scalable, Secure. Jason Rylands Energy Efficient, Modular, Scalable, Secure Jason Rylands The planning, construction and operation of IT infrastructure for mission critical applications in reliable Datacentres represents a real challenge.

More information

International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase

International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase Chris Noland cnoland@cisco.com Vipha Kanakakorn vkanakak@cisco.com 3/4/2010 Goal & Limitations

More information

Data Center Infrastructure Management ( DCiM )

Data Center Infrastructure Management ( DCiM ) Page 1 Data Center Infrastructure Management ( DCiM ) DCiM is defined by technology researchers and analysts as the integration of information technology (IT) and facility management disciplines to centralize

More information

Data Center Design: Power, Cooling & Management

Data Center Design: Power, Cooling & Management Presents Data Center Design: Power, Cooling & Management The Legacy Data Center Large (oversized) UPS Systems Large Power Distribution Systems N, N+1 UPS topologies Large Free standing Static Switches

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

Chiller Replacement and System Strategy. Colin Berry Account Manager

Chiller Replacement and System Strategy. Colin Berry Account Manager Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit

More information

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. DATA CENTRE COOLING SYSTEM A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems. 1. Cooling Optimized to Electronic

More information

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS Dr Jon Summers Scientific Leader in Data Centers Part-time Academic in Thermofluids at the

More information

Environmental Data Center Management and Monitoring

Environmental Data Center Management and Monitoring 1 Environmental Data Center Management and Monitoring A White Paper from aritan 2 Table of Contents Introduction... 3 Sensor Design Considerations... 3 Temperature and Humidity Sensors... 4 Airflow Sensor...5

More information

Rethinking Datacenter Cooling

Rethinking Datacenter Cooling Rethinking Datacenter Cooling www.sempertec.com SemperTec White Paper Rethinking Datacenter Cooling Contents Executive Summary Introduction Air Distribution: Three Cooling Design Considerations Cold Aisle

More information

ANCIS I N C O R P O R A T E D

ANCIS I N C O R P O R A T E D Thermal Design of Data Centers to Safeguard Electronic Equipment Presentation at the Thermal Design Center Santa Clara, CA, March 9, 2010 Magnus K. Herrlin, Ph.D. President Incorporated mherrlin@ancis.us

More information

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient

More information

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering What s New for Data Centers in Title 24-2013 Jeff Stein, PE Taylor Engineering SVLG Workshop November 14, 2013 About Jeff Stein Principal, Taylor Engineering 2000 - now Professional Experience Eley Associates,

More information

Data Centre Air Segregation Efficiency (ASE)

Data Centre Air Segregation Efficiency (ASE) Data Centre Air Segregation Efficiency (ASE) Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Sophia Flucker CEng MIMechE Operational Intelligence Ltd. info@dc-oi.com Abstract Data centres are large

More information

ASHRAE Data Center Standards: An Overview

ASHRAE Data Center Standards: An Overview Mission Critical Facilities ASHRAE Data Center Standards: An Overview 10012 North Dale Mabry Highway Suite 109 Tampa, FL 33618 813-792-6009 www.pergravis.com Presenter: Steve Ritzi, CDCE Pergravis is a

More information

DCIM Data Center Infrastructure Management

DCIM Data Center Infrastructure Management DCIM Data Center Infrastructure Management Part 2 Implementation Challenges & Strategic Advantages - Predictive Analysis August 8, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Implementation

More information

Implications of Current Thermal Guidelines

Implications of Current Thermal Guidelines Copyright 2010, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. This posting is by permission from ASHRAE Journal/High Performing Buildings. This material may not be copied

More information

Trends in Data Center Energy Efficiency

Trends in Data Center Energy Efficiency Trends in Data Center Energy Efficiency Presented by: Todd Boucher Better Building by Design 2012 1 Efficiency Vermont is a Registered Provider with The American Institute of Architects Continuing Education

More information

HIGH DENSITY RACK COOLING CHOICES

HIGH DENSITY RACK COOLING CHOICES WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES

More information

Green IT and Green DC

Green IT and Green DC Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental

More information

How to Increase Data Center Efficiency

How to Increase Data Center Efficiency How to Increase Data Center Efficiency Shivani Shukla Potkar Product Marketing Manager Pentair Electronics Protection High cooling efficiency & and reduced power consumption enhances the balance between

More information

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex Green Sustainable Data Centres Checklist - EU Code of Conduct on Data Centres Annex This course is produced under the authority of e-infranet: http://e-infranet.eu/ Course team prof. dr. Colin Pattinson,

More information

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation Ee The Efficient Enterprise All content in this presentation is protected 2008 American Power Conversion Corporation Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic!

More information

Experimental Study of Airflow Designs for Data Centers

Experimental Study of Airflow Designs for Data Centers Experimental Study of Airflow Designs for Data Centers Takashi Tsuchiya*, Yoshihide Suwa 2 and Ryozo Ooka 3 Technical Research Institute, Obayashi Corporation, M. Eng., Japan 2 Technical Research Institute,

More information

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services EMEA Roll-out 2 Main Mirror UK Swindon/Newbury area (15,000m 2 ) Germany Russelsheim(main)/

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information