NZQA unit standard version 2 Page 1 of 5
|
|
- Erin Briana Dickerson
- 6 years ago
- Views:
Transcription
1 Page 1 of 5 Title Demonstrate knowledge of installation practices and procedures for telecommunications network equipment Level 3 Credits 10 Purpose This unit standard covers the installation of basic telecommunication cabling, equipment, systems, and services. People credited with this unit standard are able to: demonstrate knowledge of regulatory requirements for installations; demonstrate basic knowledge of cabling and cable support installation practice; demonstrate knowledge of installation requirements for telecommunications equipment; demonstrate basic knowledge of power systems used in telecommunications installations; and demonstrate knowledge of commissioning telecommunications installations. Classification Telecommunications > Telecommunications - Service Delivery Available grade Achieved Guidance Information 1 References AS/NZS ISO/IEC 15018:2005, Information technology - Generic cabling for homes; AS/NZS 3000:2007 Electrical installations (known as the Australia/New Zealand Wiring Rules); AS/NZS 3080:2013, Information technology - Generic cabling for customer premises; AS/NZS 3084:2017, Telecommunications installations - Telecommunications pathways and spaces for commercial buildings; TIA/EIA-568A (2017) Telecommunications Wiring and Cabling Standard; Building Act 2004; Electricity Act 1992; Electricity Safety Regulations 2010; Health and Safety at Work 2015; Telecommunications Act 2001; Resource Management Act 1991; Resource Management (National Environmental Standards for Telecommunication Facilities) Regulations 2008; Local Body regulations; Telecommunications Carriers Forum Code for Residential, SOHO and Multi-dwelling Premises Wiring (Premises Wiring Code of Practice) (2011) available at and all subsequent amendments
2 Page 2 of 5 and replacements. 2 Definitions a.c alternating current. Basic knowledge employing some operational and theoretical knowledge of the subject matter to interpret available information. CPE Customer Premises Equipment. d.c direct current. EME Electromagnetic Emissions. Industry practice those practices that competent practitioners within the industry recognise as current industry best practice. UPS Uninterruptable Power Supply. 3 Evidence for outcomes 2, 3 and 4 may be demonstrated through either knowledge assessment or practical assessment. The use of diverse forms of evidence in assessment against this unit standard is encouraged. Outcomes and performance criteria Outcome 1 Demonstrate knowledge of regulatory requirements for installations. 1.1 Explain New Zealand Acts of Parliament impacting on the installation of telecommunications equipment in terms of their impact on telecommunications equipment installations. Acts Telecommunications Act, Building Act, Electricity Act, Resource Management Act; impacts may include but are not limited to requirements for registration, requirement to seek consent. 1.2 Explain regulations impacting on the installation of telecommunications equipment in terms of the requirements they impose on telecommunications equipment installations. Regulations local body regulations, Electricity (Safety) Regulations, Resource Management (National Environmental Standards for Telecommunications Facilities) Regulations, Building Regulations; requirements may include but are not limited to electrically safe, compliant with AS/NZS 3000: 2007, prescribed electrical work, penalties, wall penetration requirements, seismic strength, load bearing, fire stopping, permitted hole sizes in structural materials, EME requirements, noise limits, protection of trees and vegetation, protection of heritage sites, antenna installation and replacements, water disbursement.
3 Page 3 of Identify Standards, Codes of Practice, and acceptable solutions as tools to assist in compliance with Acts and regulations. may include but is not limited to New Zealand Standards, International Standards, Telecommunications Carriers Forum, Building Code, Electrical Codes of Practice, Simple House, Acceptable Solutions. 1.4 Explain environmental conditions that must be considered in terms of regulatory requirements when performing installations. moisture ingress, water disbursement, insect and vermin ingress, corrosion, ventilation, equipment protection, cable protection, lightning protection, notifiable substances. Outcome 2 Demonstrate basic knowledge of cabling and cable support installation practice. 2.1 Explain suitability of common telecommunications cables for a given application and in accordance with industry practice. cables copper, coaxial cable, fibre, waveguide; applications may include but are not limited to CPE, broadcasting, radio systems, access network, core network, signals and communications. 2.2 Explain colour coding or labelling, used to identify cables or cable pairs, in telecommunications cabling. copper, coaxial cable, fibre, waveguide. 2.3 Explain termination methods for common telecommunications cables, including any specialist tools. cables copper, coaxial cable, fibre, waveguide; terminations may include but are not limited to wire wrap, solder, crimp, DB connectors, internal displacement connectors, co-axial connectors, RJ connectors, fibre connectors, fibre fusion splicing. 2.4 Explain methods employed to join telecommunications cables, and their limitations. copper, coaxial cable, fibre, waveguide.
4 Page 4 of Explain cable support systems installation practices in accordance with industry practice. support systems cable tray, ladder rack, trunking, conduit, catenary wire, aerial support systems; mounting hardware fittings, fixtures, fastenings. 2.6 Explain management practices for telecommunications cable support systems. support systems cable tray, ladder rack, trunking, conduit, aerial, buried; management practice bend radius, securing, grounding, bonding, labelling, separation of services, diversity routes, cable handling techniques. Outcome 3 Demonstrate knowledge of installation requirements for telecommunications equipment. 3.1 Identify suitability of frames/cabinets for a given application. cabinets racks, frames, construction, seismic suitability, suitability for loads. 3.2 Explain equipment installation practices in accordance with industry practice. locations equipment room/closet, patch-panels, cabinets, pedestals; mounting methods wall mount, pole mount, plinth, rack mount; other considerations electrical isolation, dissimilar metals, seismic suitability, dust control during installation. Outcome 4 Demonstrate basic knowledge of power systems used in telecommunications installations. Evidence requirements 4.1 Explain types of power systems and their purpose in terms of telecommunications installations. d.c. power, a.c. power, battery backup, renewable energy, inverters, UPS. 4.2 Identify protection devices used in telecommunications installations and their application. earthing, circuit breakers, fuses, thermal overloads, surge protection, lightning protection, static protection.
5 Page 5 of Explain termination methods for extra low voltage power cables. pillar and post, crimp lug, terminal blocks, polarity, plug and socket. Outcome 5 Demonstrate knowledge of commissioning telecommunications installations. 5.1 Identify reasons for performing commissioning tests. safety, performance, harm to equipment, damage to cabling, incorrect function, compliance, warranties. 5.2 Explain common commissioning testing. visual inspections, polarity, functional tests, end to end tests, remote control access. 5.3 Identify information required before handover of installation. Planned review date 31 December 2020 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 18 July 2013 N/A Rollover and Revision 2 23 November 2017 N/A Consent and Moderation Requirements (CMR) reference 0101 This CMR can be accessed at Comments on this unit standard Please contact Infrastructure ITO qualifications@connexis.org.nz if you wish to suggest changes to the content of this unit standard.
NZQA unit standard version 2 Page 1 of 5
Page 1 of 5 Title Demonstrate knowledge of telecommunications access networks service provisioning and restoration practices Level 3 Credits 15 Purpose This unit standard covers basic underpinning knowledge
More informationNZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers
Page 1 of 5 Title Demonstrate knowledge for telecommunications premises network cablers Level 2 Credits 2 Purpose This unit standard is for people installing and maintaining telecommunications cables on
More informationNZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling
Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation
More informationNZQA unit standard version 2 Page 1 of 6. Demonstrate knowledge of telecommunications core network systems and services
Page 1 of 6 Title Demonstrate knowledge of telecommunications core network systems and services Level 3 Credits 15 Purpose This unit standard covers basic underpinning knowledge for people engaged in the
More informationNZQA registered unit standard version 2 Page 1 of 9. Install and maintain information and communications technology (ICT) systems and services
Page 1 of 9 Title Install and maintain information and communications technology (ICT) systems and services Level 4 Credits 25 Purpose This unit standard covers installation and maintenance of information
More informationNZQA unit standard version 2 Page 1 of 6. Demonstrate basic knowledge of telecommunications concepts
Page 1 of 6 Title Demonstrate basic knowledge of telecommunications concepts Level 2 Credits 10 Purpose This unit standard covers basic telecommunications principles and is intended for telecommunications
More informationNZQA unit standard version 3 Page 1 of 6. Demonstrate knowledge of telecommunications bearer and switching systems
Page 1 of 6 Title Demonstrate knowledge of telecommunications bearer and switching systems Level 4 Credits 20 Purpose This unit standard covers underpinning knowledge for people engaged in installation
More informationDemonstrate and apply knowledge of computer networking infrastructure principles
Demonstrate and apply knowledge of computer networking infrastructure principles 22713 version 1 Page 1 of 5 Level 4 Credits 15 Purpose This unit standard covers the necessary introductory skills required
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 18010 First edition 2002-05 Information technology Pathways and spaces for customer premises cabling ISO/IEC 2002 All rights reserved. Unless otherwise specified, no part
More informationNZQA registered unit standard 8086 version 7 Page 1 of 5. Demonstrate knowledge required for quality auditing
Page 1 of 5 Title Demonstrate knowledge required for quality auditing Level 4 Credits 4 Purpose People credited with this unit standard are able to demonstrate knowledge of: quality auditing, preparation
More informationQualification details
Outcome Statement Qualification details Title New Zealand Certificate in Electricity Supply (Fault Response and Switching) (Level 4) with strands in Distribution Fault Response, Distribution Network Switching,
More informationNational Certificate in Electrical Engineering (Electrician for Registration) (Level 4)
NZQF NQ Ref 1195 Version 3 Page 1 of 11 National Certificate in Electrical Engineering (Electrician for Registration) (Level 4) Level 4 Credits 249 This qualification has been revised. The last date to
More information2 Telecommunications Data Center Facility Requirements
Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................
More informationReview of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014
Review of Generic Requirements for Remote Radio Head Protection Used in Fiber to the Antenna (FTTA) Systems GR-3177-CORE Issue 1, December 2014 Telcordia Contact: Ernie Gallo Director Telcordia Network
More informationAtras Network Communications
Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry
More informationUltrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service
Ultrafast Fibre UFB s Agreement Description for Central Office and POI Co-location 1 Interpretation 1.1 The Central Office and POI Co-location described in this Description will be available from the date
More informationChorus UFB Services Agreement Service Description for Central Office and POI Co-location Service
Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description
More informationUltrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service
Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More informationNZQF NQ Ref 1093 Version 3 Page 1 of 10. This qualification has been reviewed. The last date to meet the requirements is 31 December 2022.
NZQF NQ Ref 1093 Version 3 Page 1 of 10 National Certificate in Electronic Engineering (Level 3) Level 3 Credits 117 This qualification has been reviewed. The last date to meet the requirements is 31 December
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationINSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationNorthpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service
Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service 1 Interpretation 1.1 The Direct Fibre Access Service described in this Service Description will be available
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More informationNZQA unit standard version 2 Page 1 of 5. Demonstrate knowledge of and install wireless local area computer networks
Page 1 of 5 Title Demonstrate knowledge of and install wireless local area computer networks Level 6 Credits 15 Purpose This unit standard covers installation of wireless local area networks including
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationOffice of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO
Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note
More informationInstallation Manual for D1800 Series High Power PoE Midspan Power Supply
Installation Manual for D1800 Series High Power PoE Midspan Power Supply Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A - Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationPoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS
PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS Version 14 November 19, 2014 Digital Realty Table of Contents INTRODUCTION... 3 ACCESS TO THE POP ROOMS, ISP & OSP... 3 PoP- MoP Forms... 3 Who must
More informationWORLDSKILLS STANDARD SPECIFICATION
WORLDSKILLS STANDARD SPECIFICATION Skill 02 Information Network Cabling WSC2015_WSSS02 THE WORLDSKILLS STANDARDS SPECIFICATION (WSSS) GENERAL NOTES ON THE WSSS The WSSS specifies the knowledge, understanding
More informationSection 21. Telecommunication Hardware. BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
More informationAT&T Virtual Private Network Service (VPN) and AT&T VPN Express
AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation
More informationInstallation Instructions for the AUTOcard-SA System
Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,
More informationEmerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.
Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationSPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING
PART 1: GENERAL 1.01 SCOPE OF WORK A. The Designer and Contractor are responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the
More informationSPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS
SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors
More informationUser Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011
An Expert in Optical Communications User Manual AN5506-01-A GPON Optical Network Unit Version: A Code: MN000000943 Date: December 2011 FiberHome Telecommunication Technologies Co., Ltd. Version Version
More informationAT&T Switched Ethernet Service SM
Site Preparation Guide AT&T Switched Ethernet Service SM December 2016 2016 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks
More information17. Microwave Collocation 17.1 General
Original Page 1 17.1 General 17.1.1 General A. Unless otherwise specified herein, general regulations contained in Sections 1 through 4 and Sections 14 and 15 apply in addition to the regulations contained
More informationThis unit standard is expiring
Page 1 of 5 Title Demonstrate and apply knowledge of a personal computer system Level 1 Credits 3 Purpose People credited with this unit standard are able to: demonstrate knowledge of the hardware components
More informationQualification details
Qualification details Title New Zealand Certificate in Construction Related Trades (Supervisor) (Level 4) [Ref: 2381] Version 1 Qualification type Certificate Level 4 Credits 58 NZSCED 040399 Architecture
More informationAREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.
AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationICT30110 Certificate III in Broadband and Wireless Networks Technology
ICT30110 Qualification Notes Certificate III in Broadband and Wireless Networks Technology Descriptor This qualification reflects the role of a tradesperson with a range of telecommunications skills who
More informationAS1008-P AS1026-P AS2008-P AS2024-P User Manual
Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationInstallation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010
Installation instructions RF-identification system with integrated AS-i slave UK DTSLF 704153 / 07 04 / 2010 Inhalt 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationone cool inverter. GT Series Solar Inverter Quick Install Guide v1.4
one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 This quick installation guide must be used in conjunction with the Installation Manual. For installation support contact your local
More informationSmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide
SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide Approval Models that are equipped with telecom interfaces have been approved for connection to the public telecommunication
More informationCourse outline: 221 Cabling G106A UEENEEG106A - Terminate cables, cords and accessories for low voltage circuits
RTO Code 41319 Course outline: 221 Cabling G106A UEENEEG106A - Terminate cables, accessories for low voltage circuits Qualification: Applicable to: Unit of competency: Related policies: Monitor review:
More informationInstallation instructions Ethernet switch EC / / 2011
Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................
More informationOwner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications
Warranty Registration Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual ECO-UPS Systems with LCD Models: ECO650LCD, ECO850LCD Not suitable for
More informationHigh Performance Network Isolator
EMOSAFE EN-1005 + High Performance Network Isolator Product Datasheet 1 FEATURES AND ADVANTAGES High performance Gigabit Ethernet 5.0 kv AC dielectric strength 8.5 kv DC dielectric strength Conforms to
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationWS must be used in a temperature controlled place. It is compliant to ETS Class T
Important Information about the Sagemcom F@ST 2705 WS: Operational working: F@ST2705 WS must be used in a temperature controlled place. It is compliant to ETS 300 019-1-3 Class T 3.2 standard: 1. Temperature
More informationBulletin Installation of solar photovoltaic systems Rules , , , , and
Bulletin 64-5-0 Installation of solar photovoltaic systems Rules 64-060, 64-200, 64-214, 84-020, 84-024 and 84-030 Scope (1) Introduction (2) Disconnecting means (a) Disconnecting means for solar photovoltaic
More informationChapter 1 Introduction to Outside Plant
Chapter 1 Introduction to Outside Plant Chapter 1 offers an overview of outside plant (OSP) fundamentals. An introduction to standardization and valuable resources for the OSP designer are also included
More informationBasics of Industrial Electricity and Troubleshooting Electrical Control Circuits
Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology
More informationDocument Title Issue Date. TBE/KBE-DOC TBE/KBE Document List TBE/KBE-REV TBE/KBE Revision List
Sid 1 (6) TBE/KBE DOCUMENT LIST Document Issue Date Supersedes TBE/KBE-DOC 12.0 2013-08-20 Issue 11.0 TBE/KBE-DOC TBE/KBE Document List 12.0 13-08-20 TBE/KBE-REV TBE/KBE Revision List 12.0 13-08-20 TBE/KBE
More informationSubmission to the Australian Government Consultation on Possible Amendments to Telecommunications Carrier Powers and Immunities.
Submission to the Australian Government Consultation on Possible Amendments to Telecommunications Carrier Powers and Immunities July 2017 Opening Local Government NSW (LGNSW) is the peak body for local
More informationFTTH Planning and Design Training Guideline for Telecommunications Companies
FTTH Planning and Design Training Guideline for Telecommunications Companies Publication Date: 20th January, 2015 Document Number: Version 0.2 DRAFT Document Control Document Authorities Document Details
More informationVRp Three-Phase Precision AC Voltage Regulator
VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6)
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationG.SHDSL NTU with Fixed Serial Interfaces
DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,
More informationNational Certificate in Extractive Industries (Mining Administration B Grade Tunnel Manager) (Level 5) with an optional strand in Coal Mine Deputy
NZQF NQ Ref 1535 Version 4 Page 1 of 9 National Certificate in Extractive Industries (Mining Administration B Grade Tunnel Manager) (Level 5) with an optional strand in Coal Mine Deputy Level 5 Credits
More informationElectrical Integration of PV Systems. Ridha Hamidi, Ph.D.
Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various
More informationMAINS DISTRIBUTION UNIT MDU14-CO
MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200,
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationThis qualification has been revised. The last date to meet the requirements is 31 December 2021.
NQF Ref 0223 Version 6 Page 1 of 8 National Certificate in Electrical Engineering (Level 3) Level 3 Credits 149 This qualification has been revised. The last date to meet the requirements is 31 December
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationTVAC25100 TVAC25110 User manual
TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the
More informationInstallation instructions Inclination sensor EC2019 EC / / 2013
Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics
More informationTitle Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)
Discipline Engineering Standard - NSW Category Signalling Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units Reference Number SPS 30 - (RIC Standard: SC 09 10 07 00 SP)
More informationEMOSAFE EN-85e Network Isolator with Overtension Auto-Release
EMOSAFE EN-85e Network Isolator with Overtension Auto-Release Product Datasheet 1 FEATURES AND ADVANTAGES 1.1 OVERVIEW High Performance Gigabit Ethernet 4.6 kv AC dielectric strength 8.5 kv DC dielectric
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationTXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O
s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point
More informationQualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001
Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon, Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design
More informationAT&T Virtual Private Network Service (VPN) and AT&T VPN Express
AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site Preparation Guide 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered
More informationB60 Domestic Voltage Optimisation Unit
B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,
More informationDigital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025)
Digital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025) This series of digital power probes by Networked Robotics is used to record a yes/no indication of the presence
More informationRemote RMM-1400 Intelligent Remote Site Management Device. Installation Guide
Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox
More informationTest Report S
Sunkom Pty Ltd FDX card s A101, A102, A104 and A108 Laboratory Details All tests were performed at : Comtest Laboratories Pty. Ltd. Unit 1 / 570 City Road South Melbourne Victoria 3205 Australia Telephone
More informationAT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationExternal Assessment Specifications Document Curriculum. NQF Qualification Title Code
External Assessment Specifications Document Curriculum NQF Qualification Title Code Level 671101000 Occupational Certificate: Electrician 4 Name E-mail Phone Logo National Assessment Artisan Quality Moderation
More informationICT30610 Certificate III in Broadband and Wireless Networks Qualification Notes
ICT30610 Qualification Notes Certificate III in Broadband and Wireless Networks Descriptor This qualification reflects the role of a tradesperson with a range of telecommunications skills who can: install
More informationManual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics
Manual Network Expansion Port 2 NEP-2 English www.lowrance.com www.simrad-yachting.com Brands by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain
More informationAT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T
More informationUnit descriptor. Employability skills Prerequisite units. Co-requisite units. Application of the unit. Competency field Unit sector
ICTCBL2005A Install customer cable support systems ICTCBL2005A Unit descriptor Install customer cable support systems This unit describes the performance outcomes, skills and knowledge required to install
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationTruRead Plug and Play Pulse Splitter Type L4SK0. Document Version 1.02
Type L4SK0 Document Version 1.02 Introduction TruRead Plug and Play Pulse Splitter This document describes the requirements and considerations for installation of the L4SK0 Plug and Play Passive Pulse
More information