DESIGN GUIDELINES. Building Circulation

Size: px
Start display at page:

Download "DESIGN GUIDELINES. Building Circulation"

Transcription

1 DESIGN GUIDELINES Building Circulation Conceptual Plan FUNCTIONAL AREA DESCRIPTION Building circulation includes all the elements which enable people (including those with disability restrictions) to circulate through the building. A well designed circulation system should support clear way -finding, allowing users to identify entrances, move easily between floors, and find their final destinations with a minimum of effort. Users should be able to find and use public amenities such as restrooms, phones, and drinking fountains easily. Circulation components are the most viewed and used spaces within a building and require materials with exceptional durability. The overall impression of a building lies largely with the visual character of the circulation components. Lobbies Lobbies allow large groups to enter and gather within a building. They serve as focal points that orient users. In addition to the main lobby, additional lobbies should be considered outside any space where large numbers of people gather, including the multipurpose room and gymnasium. Any functional area entered from the lobby gains prominence within a building. These often include the Information Center and Administration spaces. Corridors Connecting all the spaces together, corridors allow movement through the building. In temperate areas, these may actually be simply covered exterior walkways. Due to code and security issues, avoid dead end corridors. Avoid layouts that create bottlenecks and excessive cross traffic. The key dimension is the corridor width. Learning Studio doors should be recessed when they open into corridors so that they do not swing into the path of travel. Stairs Most importantly, stairs need to satisfy the egress and area of refuge requirements dictated by applicable codes. Place stairs in locations that facilitate both the arrival and dismissal of students as well as class changes. Consider the impact of the stairs on adjacent corridors and lobbies, since they tend to be bottlenecks in the circulation. This can be mitigated by over-sizing the width of these elements (min - 0 wide (124 mm)). Interior door widths at the top and bottom of stairways that feed into corridors shall be at least 6-0 wide (1829 mm). Install the normally 17 January 2012 open type of doors with magnetic releases. Ensure compliance with applicable codes for headroom and railing placement. Avoid open wells which encourage students to drop objects down through them. Provide exterior protection from the weather if the exterior doors will be used as a point of entry. Elevators The elevators enable those unable to use the stairs to change levels. Custodial staff will also use the elevator to move materials. The elevator should be centrally located. It should not be a prominent part of the design. The elevator must be ADA accessible, lockable, and remotely return to the first floor. Entrances/exits Entrances and exits need to satisfy the egress requirements dictated by applicable codes. Exit signs should be visible from any location along the path of travel. Entrances need to be coordinated with AT/FP access control guidelines. Door hardware also needs to be coordinated with AT/FP access control guidelines. The use of electronic, lock and/or ID credential systems or combinations thereof, will be based on local area requirements. BUILDING CIRCULATION 1

2 DESIGN GUIDELINES Building Construction EXTERIOR Coordinate the design with the local jurisdiction from the beginning of the project. Comply with base and local guidelines. Use durable low maintenance materials. These include masonry, concrete, and stone. Window/door hardware and glazing shall meet AT/ FP design requirements. Though the design should have enough variation in form to be interesting and meet local design criteria, avoid creating niches and hidden building areas which create security blind spots. A hierarchy of entrances should allow visitors to easily find their way to the main entry. Additional prominent entries for athletic or arts facilities may make this more difficult. In addition, site limitations may require the use of entries other than the main entry for student arrival and dismissal. Light all exterior doors. FACILITY ELEVATIONS Although project site and Base Master Plans have a major impact on overall building design and its associated elevation, there are several dictates that should be followed: Education facilities should be three (3) floors maximum. Two stories is the preferred solution. In accordance with National Life Safety codes, Grades 1 and below shall be placed on the 1st (Ground) floor. Second grade cannot be above the second floor. For design purposes, it is recommended that approximately 60 percent of the classrooms and major school support functions be placed on the 1st (ground) floor. A split-level facility may be considered where terrain/ site elevations dictate, thus allowing students to move either up or down one floor for classroom access. Facility designs shall take into consideration AT/FP progressive collapse criteria and local area seismic requirements. INTERIOR Use durable low maintenance materials. Comply with all Anti-Terrorism / Force Protection standards to include access control. Create easily supervised and understood circulation paths. Place vertical circulation in locations that allow arriving and departing students to quickly move to the appropriate floor without traversing other floors. Use variation in ceiling heights to call attention to entries. Use this variation to create a hierarchy that calls more attention to special one-of-a-kind rooms (Information Center) over typical instructional spaces. Zone spaces that may be used after hours by the public so that they can be closed off from the remainder of the facility. Provide a means of securing these assembly spaces so that users do not gain access to the entire facility when attending a function. Public restrooms must be included in the segregated area. Provide for ADA Accessibility. Areas of refuge, fire and smoke compartmentalization should be considered. 17 January 2012 UTILITY SYSTEMS (HVAC/ELECTRICAL/ MECHANICAL/COMMUNICATIONS) Utility systems should be located in the facility where they are not intrusive, and located for easy maintenance access for major system components subsequent to construction. Electrical/Mechanical support tie-ins to the facility shall be underground. Designers shall develop interior HVAC/Electrical/ Mechanical/Communication corridors in the building for easy maintenance access and future upgrades. Comply with AT/FP design standards. As new and renovated facilities become more "closed" due to new AT/FP glazing and frame requirements, HVAC becomes more an issue. Facilities should have a minimum of four (4) changes of air ventilation per hour. All areas should be designed for forced ventilation with or without air conditioning. The facilities HVAC system design should be in accordance with ASHRAE 62 and local host nation requirements as applicable. Air conditioning should be provided in geographical areas where it is required. Engineers and school administrators need to check with their assigned Area Office to determine if air conditioning is applicable to their particular geographical area. Electrical outlets located near sinks must be GFCI, per code. All administrative offices and technology areas should have ample electrical outlets installed. In offices, provide one duplex receptacle per wall, minimum. BUILDING CONSTRUCTION 1

3 DESIGN GUIDELINES Local Area Network The total oversight and management responsibilities for information assurance (IA) and protection of DoDEA s critical infrastructure fall under the purview of the DoDEA Chief Information Officer (CIO) and DoDEA IA Chief. All requests for use of wireless technologies within DoDEA are to be routed to the DoDEA CIO and DoDEA IA Chief for approval. It is the responsibility of the contractor or reader to be familiar with and to comply with the federal and industry Local Area Network (LAN) standards as referenced documents in Reference A for design, installation, and testing of all components. Contractors must also comply with federal and DOD LAN guidelines and standards (See Reference B). Due to emerging network technologies, the LAN Standards shall be reviewed on an annual basis. Check with your Area Information Technology (IT) Director or DoDEA IT to ensure that this is the most current LAN standard. Planning Requirements Typical Features: Telecommunication and LAN Room(s) sf per room (6. m2-10 m2) - subject to actual equipment and required clearances. Built-In Furnishings LAN equipment racks (option-based on chosen model) Finishes Floor: an antistatic surface such as tiled or sealed concrete, carpet is prohibited. Base: as appropriate for flooring material. Ceiling: no finish, waterproof, no suspended ceilings. The height of the ceiling from the floor level must be no less than 8-6 (260cm) high. Walls: concrete block, reinforced concrete, plaster, drywall or other locally available, durable material. Equipment LAN equipment (as required) LAN component racks Punch boards (as required) minimum 4 x 8 x ¾ (122cm x 244cm x 19mm) plywood Rack mounted servers (as required) Electrical Fluorescent lighting (00 lux minimum at desk height) General purpose outlets as required for equipment (110V and 208V in USA, utilize comparable standards for facilities outside USA) Rack mounted servers Concentrator Fire Protection Fire protection system as required by NFPA Telecommunications Telecommunications Rooms Telecommunications Rooms (TR) are special-purpose rooms that house telecommunications equipment. These rooms have stringent requirements due to the nature, size, expense and complexity of the equipment housed in them. TR sizes vary according to the size of the building, number of floors, occupancy characteristics and telecommunications 17 January 2012 services required. Consideration to the future needs of the facility and the end users is a necessity. TR Nomenclature/Designation TR numbers will be designated as follows. The cable entrance point of the building will be designated as TR1. Additional TR rooms will be designated as TR2, TR3, etc. starting in the basement or first floor, then additional floors as required. If more than one TR exists on each floor, then the TRs will be numbered in order of installation. Room Dimensions TRs must be at least 10 ft x 10 ft (3m x 3m) to accommodate the telecommunications cabinets. They must be located in such a way as to provide the most advantageous cable routing and positioning of cabinets. In other words, the location of the TRs must take into account the size of the building, the required length of cable runs, the types of electronic equipment required to service the entire building. In addition, TRs may not be located or co-located with steam, electrical power, or environmental control rooms nor may they be in areas that may suffer flood damage or where flood damage occurred and has not been repaired. Cabinet Types Server Cabinets shall have specific dimensions to accommodate various size servers. In reference to the Dell 4210 Cabinets currently in use, dimensions of this model cabinet are 39 (100cm) tall, 24 (61cm) wide, and 39 (100cm) deep 39 (1-meter) depth is mandatory. The rack must have 42 Rack Units (RU). Figure 1 depicts server cabinets. 1

4 For network equipment and local area copper cabling, the Local Area Network (LAN) cabinets should be utilized. A common model is the 42RU Rittal Cabinet as shown in Figure 2. These cabinets provide sufficient space for the horizontal cabling patch panels and patch cords that connect into Access Layer Switches as shown in Figure 2. The dimensions are 4 (11cm) high, 32 (82cm) wide, and 3 (90cm) deep. The rack must have 42 RUs. LAN Cabinets will be equipped with thermostat controlled ventilation system (consisting of two ventilators) mounted in the top panel without loss of height units. Thermostat will be installed in front, left corner. LAN cabinets will be equipped with an 8 (20 cm) 14 W fluorescent light fixture including electronic ballast and installed top, front and centered in horizontal position without loss of height units. Cabinets should be equipped with a 19 (48 cm) telescoping convenience shelf to accommodate administrative requirements. All cabinets will be equipped with a ft (1. m) grounding bar, installed vertically against a rear leg of frame. If the RJ-4 patch panels have the ground lug positioned on the left side the ground bar will be mounted on the left leg. If the RJ-4 patch panels have the ground lug positioned on the right side the ground bar will be mounted on the right leg. Cabinets will be positioned in room in such a way as to provide front and rear access. If cabinet is a standalone cabinet, then the cabinet must have three- (3) sided access (front, rear and one side). Cabinet cable entry will be on sides, top and bottom of the cabinets. Cabinets may be bolted to the floor but is not necessary. The server racks have stabilizing platforms that must be installed. Figure 1 shows an example of front and back rack stabilizers. Placement of TRs A TR will be located on each floor at a minimum. Additional cabinets per floor may be necessary if the distances to the wall outlets exceed the maximum length of 29 ft (90m). Copper LAN cables will not be installed between floors. Physical Room Security Security locks will be provided for the TR and keys will be issued only to IT Division, Facility, and Security personnel authorized access by the IT Division Chief or required for access by fire personnel (per the NFPA). All LAN cabinet locks shall be identically keyed for management ease. The TR will be secured with a traditional lock and key system that will be keyed different than the LAN cabinet key. Cable Tray 4 (10cm) deep cable trays will loop the entire perimeter inside a TR at no less than 8 ft (244cm) above the floor. Maintain a 4 (10cm) clearance from each wall. Universal 12 (30cm) cable tray (see figure 3) will be installed at the top of the communications racks spanning the width of the room. (The use of a cable tray is ideal for installing all low voltage cables; telephone, television, security, data cables etc. at the time of installation, saving time and money. Installing a cable tray with space for future cabling also Figure 1-server cabinets Figure 2-LAN cabinet 2

5 provides an easy way to add data cables in the future without extensively disturbing the existing ceiling. Drainage Telecommunications rooms will not have floor drains in order to avoid the threat of back flooding. Telecommunication rooms shall not be located in any area that presents a high risk of water damage to the network equipment. Electrical Requirements Conditioned power will be delivered to each cabinet via an overhead cable tray. An online power backup source will support the following requirements. In all LAN and Main Distribution Frame (MDF) TRs, for each cabinet there must be installed three (3) 16 amp circuit breakers above a new server cabinet or LAN cabinet. Each circuit shall be on a different electrical phase. For the server cabinets, splice a Power Distribution Unit (PDU) power cable into each circuit with enough length to enter the cabinet in the front hole, shown in Figure 4, and reach the floor of the cabinet. Figure 4 shows three different phased 220V AC power in a splice box with the black PDU power cables splicing into the circuits. Figure, shows where the three PDU are located in the server cabinet. These PDUs are mounted on the right side facing the back of the server cabinet. Each PDU is mounted directly below each other. All cables need to reach the floor to ensure there is sufficient length. This distance may vary depending on how these circuits are mounted. Figure 3-cable trays Figure 4-front view of 16 amp circuits Figure 4-front view of 16 amp circuits Figure -top PDU locations in the server rack 3

6 From the 16 amp junction boxes, LAN cabinets will have two (2), seven-receptacle power strips, without switches. These power strips will be installed at the rear, lower half of the inner frame of the cabinet, one on the left and one on the right, and will have the receptacles facing towards the middle (not towards the front of the cabinet). Power cable will be installed in one continuous length without splicing. This rule may be waved in certain situations, but not if power cables run under a raised floor along with the facility air conditioning. Power will enter the cabinet and terminate to junction boxes mounted on the lower right side horizontal support and centered. The junction boxes will be labeled (on the box if possible) showing the distribution panel number and its fuse number. Each cabinet will be separately grounded (from the cabinet busbar) to the Telecommunications Main Ground Busbar (TMGB) or to the Telecommunications Ground Busbar (TGB) installed in the TR and connected to main building ground. Ground wires will be terminated on the TMGB or the TGB. Ground wires must be continuous with no splices. Environmental A dedicated air conditioning (A/C) unit shall be installed in each LAN, communications, and online backup system room to maintain temperature and humidity to a maximum of 68 degrees Fahrenheit (20 degrees Celsius) and 40-0 percent relative humidity. Rating of A/C units should be based on the heat generation and power consumption ratings of the installed equipment to maintain this ambient level. Fluorescent lighting shall be installed to provide 00- lux minimum at desk height. The area must be clean, temperature controlled and large enough to allow full and unimpeded access to the cabinet for installation and maintenance requirements. Grounding A communications ground (#6 AWG minimum) shall be installed from the main service entrance ground bus to each LAN and TR LAN cabinet and terminate on a copper ground plate located in the bottom rear of the cabinet. No Additional Utilities No plumbing, HVAC, or electrical conduit shall pass through, or be directly above, the Telecommunications room. In renovation projects where new Telecommunications rooms are established, all overhead utilities will be relocated out of the room. Telecommunication Room Requirements Main Distribution Frame (MDF) TR The MDF TR is a physical room located in a centralized area of the school complex used to aggregate vertical fiber optic cabling from TRs and accommodate enterprise servers, routers, and phone systems. Input power for the entire room will be provided from an online backup system. A minimum of 2-4 LAN cabinets are required to support the majority of all LAN connectivity and IT resource requirements. The Server Cabinets suitable for mounting servers while the LAN Cabinets are suitable for LAN Equipment. Additional LAN cabinets (maximum of 6) may be Figure -Middle PDU Locations in the Server Rack Figure -Bottom PDU Locations in the Server Rack 4

7 required to support site-specific requirements and future technologies. A minimum of 39 (1m) clearance around the entire LAN cabinet and unrestricted access to all cabinet doors and side panels is necessitated. In situations that present space limitations, a maximum of two cabinets may be bolted together with three sides of each cabinet still accessible as seen in Figure 6. Local Area Network (LAN) TR Physical rooms located throughout a building that contain LAN cabinets required to connect horizontal copper cabling between patch panels and room wall outlets. Each TR will connect to the MDF via fiber optic cabling. At minimum, one TR shall be allocated per building per floor. In multi-level buildings, it is feasible to configure TRs on top of each other for ease of maintenance and future upgrades. Adequate clearance around the entire LAN cabinets and unrestricted access to all cabinet doors and side panels is necessitated. Vertical Cable Infrastructure - Fiber Optics Renovation projects or additions to existing LAN infrastructure At a minimum, backbone network cabling shall consist of one (1) 4-strand, 62./12-micron multimode fiber (MMF) optic cable terminated in a fiber optic distribution panel with ST connectors and one (1) 8-strand 9/12-micron single-mode fiber (SMF) optic cable terminated in a fiber optic distribution panel with SC connectors. The installation of MMF in renovation projects allows for backward compatibility with existing legacy networks already using this technology. SMF optic cabling provides more efficient Figure 6-top view example of MDF TR Figure 6-top view example of MDF TR Figure 7-top view example of LAN TR Figure 7-top view example of LAN TR

8 data throughput, increased bandwidth capacity, and greater distance support in comparison to MMF optic cable. Fiber optic cabling shall meet all applicable EIA/TIA 68 B.3 standards capable of supporting 1000Base-T and 10GBASE-T deployments conforming to IEEE 802.3ae and 802.3an. New Construction MILCON Projects At a minimum, backbone network cabling shall consist of one (1) 12-strand, 9/12-micron singlemode fiber (SMF) optic cable terminated in a fiber optic distribution panel with SC connectors. Fiber optic cabling shall meet all applicable EIA/TIA 68 B.3 standards capable of supporting 1000Base-T and 10GBASE-T deployments conforming to IEEE 802.3ae and an. Installation Guidelines: Install plenum-rated cabling where applicable. Fiber optic patch panels shall be located in the upper portion of the LAN cabinet. Single-mode fiber will be terminated with SC connectors Multi-mode fiber will be terminated with SC connectors. Provide 48 (122cm) service loop for fiber optic cables in each LAN cabinet. Excess cable shall be located neatly in cable tray. Machine printed labels will be provided for fiber optic patch panel identification. Fiber optic patch panel labeling will include type, cable number, count, and cable size at the terminal points. See Table 1 for an example of labeling fiber cabling. All fiber optic cabling will be certified to EIA/TIA 68 B.3 standards. Test report data must be presented, unaltered, in a common electronic format prior to acceptance of horizontal cabling infrastructure. FOC 01, 1-12, 12SM FM: BLDG, TR1 TO: BLDG, TR2 FOC 01, 1-6, 6MM FROM: BLDG, TR1 TO: BLDG 70, TR10 Table 1-examples of labeling fiber cabling Horizontal Network Cabling The category of cabling used must be determined by the purpose and project requirements. For renovation projects or addition of LAN drops in existing facilities, the same type of copper cabling should be used. In all new constructions, Cat 6 Class E cabling is the standard horizontal cable. The cabling shall be installed in continuous, un-spliced, lengths between the LAN cabinet patch panel and the classroom or office wall outlet. It cannot exceed 29 ft (90m). All cabling installations shall conform to applicable Electrical Code, local regulations, and EIA/TIA 68 B.2 standards. Type Speed Information Cat. E (Class D) 10/100/1000 MbE Maximum cable distance 90m, minimum of 100Mhz of bandwidth Cat. 6 (Class E) 10/100/1000 MbE/10GbE Table 2-copper cable specifications Maximum cable distance 90m, minimum of 100Mhz of bandwidth Installation Guidelines Each LAN cabinet has a maximum capacity of 216 drops. Note that this includes all data, telephone, and wireless AP drops. Install plenum-rated cabling where applicable. Copper patch panels will be located in the upper portion of the LAN cabinet and will be separated by 1 RU of space. In this 1 RU of space, Cable guides should be installed to keep acceptable cable management standards. Cables shall run parallel or at right angles to the building structure and shall not be installed diagonally across ceiling spaces. Cables shall be supported by J-Hooks or equivalent, installed at intervals not exceeding ft (12cm) between supports, and be permanently anchored to building structure or building surfaces. Cabling shall not be supported from ductwork, water or waste piping, electrical conduits, suspended ceiling supports, or be supported from the ceiling suspension system. Provide 24 (61cm) service loop for cables at each LAN cabinet. Excess cable shall be located neatly in cable tray. Provide 12 (30cm) service loop at each LAN wall outlet. Excess cable shall be located in wall, conduit, or ceiling. Machine printed labels will be provided for copper patch panel, media, and the wall outlet identification. Copper patch panel labeling will include TR number or room number, patch panel number, and port number. 6

9 Wireless Network Wireless technology requires additional LAN drops at ceiling level to support Wireless Access Points (APs). These APs provide network connectivity for approximately computers over a limited range of distance. Based on physical area, building structure properties, and number of users, DoDDS-E network administrators determine the placement of wireless access points throughout the school. 4.1 Wireless Installation Power Power to these APs is provided by the network equipment through Power over Ethernet (POE) switches. No additional power requirement is needed. Indoor Installation The best practice is to install a minimum of one drop in the center of the room above the ceiling. Rooms where these drops will be located will be coordinated with AE firms during design and clearly annotated on as-built construction drawings. This will allow the network installers to easily locate the drop and give them the flexibility to install the AP anywhere on the ceiling to provide maximum effectiveness and signal quality to the users. The installation team is required to mark the location of ceiling LAN drops on the LAN box and drop ceiling (if applicable). Outdoor Installation Mounting outdoor wireless equipment needs to be weatherproof but does not require the LAN drop to be located outside the building. The antenna cables are typically long enough to connect from the AP to the external antenna. The antenna must either be able to withstand the outdoor elements or be enclosed in such a manner to withstand the elements. Protective Covering In gymnasiums and multipurpose rooms, a protective enclosure suitable to protect the wireless network equipment. The protective enclosure shall be designed to protect the access point from stray objects while still allowing adequate signal levels to the clients. Cable Termination Wireless access point cabling shall be terminated in a patch panel separate from normal wired connections and should not exceed more than 24 ports per LAN cabinet. It is the Department of Defense (DoD) standard to keep the wireless network physically and logically separated from the data network due to security risks associated with wireless. This is the most effective and robust design along with the ability to add future security equipment to protect network. DoD Wireless Policies Wireless technologies that are integrated or connected to DoDEA networks must comply with DoD Directive and DoD Instruction Wireless technologies under consideration for access to DoDEA networks and information are required to undergo vulnerability testing, complete the Interim DoD IA Certification and Accreditation Process Guidance. DoD Information Assurance Certification and Accreditation Process (DIACAP), previously known as the Department of Defense Information Technology Security Certification and Accreditation Process (DITSCAP), must meet DoD standards and security requirements, and be approved by the DoDEA Chief Information Officer (CIO). Activities considering wireless technologies for use in a test or educational setting must ensure that there is physical and logical separation from any DoDEA network, in addition to, physical and logical separation from any associated DoD networks, and that those technologies do not process unclassified, sensitive, or privacy information. DoD has provided guidance for wireless technology in DoD Directive Voice Over Internet Protocol (VoIP) System The majority of current school LANs will support VoIP technologies without a major upgrade in cable infrastructure. The VoIP phones implemented throughout DoDDS-E, for example, have an additional port to allow a computer access to the network. The phone power is supported by Power Over Ethernet (POE) technology that originates from the network equipment in the telecommunication rooms. It is always recommended to survey a building considering VoIP implementation to best determine additional infrastructure requirements. Such additional requirements may include infrastructure upgrades for wireless networks, IP based overhead paging speakers, and phone trunk connections. Please consult the DoDEA IT Division for further guidance on VoIP requirements. 7

10 SMART Board Installation The school principal will validate requirements for installation of wall-mounted SMART Boards and ceiling mounted LCD projectors with the educational technologist assigned to their school. Once validated, the principal is responsible for the submission of a work request with their local facilities office for action. Installation standards: One SMART Board 680 One electrical outlet located within 6. ft (2m) from center of the SMART Board (not required if an existing outlet is located within the recommended distance allocation) One universal projector ceiling mount One electrical outlet located within 1 ft (30cm) of projector ceiling mount One wall mounted combination USB/VGA terminal One USB cable (provided with SMART Board) connected to the SMART Board and hardwired into the wall mounted USB/VGA terminal One VGA cable connected to the LCD projector (to be provided by DoDDS) and hardwired into the wall mounted USB/VGA terminal Recommended mounting heights from floor to bottom of SMART Board are as follows: Grades K-2 at 26 (66cm), grades 3- at 30 (76cm), grades 6-12 at 36 (91cm) Mounting of SMART Boards will require coordination with existing wall mounted equipment/furnishings, such as LAN raceways, whiteboards/chalkboards/ bulletin boards, cabinets and may require relocation/ removal of some equipment/furnishings. Reference C lists rooms that are authorized installation of wall mounted SMART Boards and ceiling mounted LCD projectors: Online Backup System To protect network resources and LAN equipment from damage or data loss resulting from electrical surges or power outages, online backup systems are needed. An online backup system shall be the recommended system installed to provide conditioned power to network resources and LAN equipment installed in communication and LAN rooms. The online backup system shall be hard wired into the building main power and will provide a minimum of 120 minutes back up power when a power outage has incurred. The online backup system should also provide standby power for approximately three days. Accurate wattage consumption for all planned equipment will be provided to allow for selection of an online backup system that can support the existing power requirements. Placement of the online backup system battery room should be on the ground floor and will be climate controlled to 68 degrees Fahrenheit (20 degrees Celsius). 8

11 DESIGN GUIDELINES Local Area Network The total oversight and management responsibilities for information assurance (IA) and protection of DoDEA s critical infrastructure fall under the purview of the DoDEA Chief Information Officer (CIO) and DoDEA IA Chief. All requests for use of wireless technologies within DoDEA are to be routed to the DoDEA CIO and DoDEA IA Chief for approval. It is the responsibility of the contractor or reader to be familiar with and to comply with the federal and industry Local Area Network (LAN) standards as referenced documents in Reference A for design, installation, and testing of all components. Contractors must also comply with federal and DOD LAN guidelines and standards (See Reference B). Due to emerging network technologies, the LAN Standards shall be reviewed on an annual basis. Check with your Area Information Technology (IT) Director or DoDEA IT to ensure that this is the most current LAN standard. Planning Requirements Typical Features: Telecommunication and LAN Room(s) sf per room (6. m2-10 m2) - subject to actual equipment and required clearances. Built-In Furnishings LAN equipment racks (option-based on chosen model) Finishes Floor: an antistatic surface such as tiled or sealed concrete, carpet is prohibited. Base: as appropriate for flooring material. Ceiling: no finish, waterproof, no suspended ceilings. The height of the ceiling from the floor level must be no less than 8-6 (260cm) high. Walls: concrete block, reinforced concrete, plaster, drywall or other locally available, durable material. Equipment LAN equipment (as required) LAN component racks Punch boards (as required) minimum 4 x 8 x ¾ (122cm x 244cm x 19mm) plywood Rack mounted servers (as required) Electrical Fluorescent lighting (00 lux minimum at desk height) General purpose outlets as required for equipment (110V and 208V in USA, utilize comparable standards for facilities outside USA) Rack mounted servers Concentrator Fire Protection Fire protection system as required by NFPA Telecommunications Telecommunications Rooms Telecommunications Rooms (TR) are special-purpose rooms that house telecommunications equipment. These rooms have stringent requirements due to the nature, size, expense and complexity of the equipment housed in them. TR sizes vary according to the size of the building, number of floors, occupancy characteristics and telecommunications 17 January 2012 services required. Consideration to the future needs of the facility and the end users is a necessity. TR Nomenclature/Designation TR numbers will be designated as follows. The cable entrance point of the building will be designated as TR1. Additional TR rooms will be designated as TR2, TR3, etc. starting in the basement or first floor, then additional floors as required. If more than one TR exists on each floor, then the TRs will be numbered in order of installation. Room Dimensions TRs must be at least 10 ft x 10 ft (3m x 3m) to accommodate the telecommunications cabinets. They must be located in such a way as to provide the most advantageous cable routing and positioning of cabinets. In other words, the location of the TRs must take into account the size of the building, the required length of cable runs, the types of electronic equipment required to service the entire building. In addition, TRs may not be located or co-located with steam, electrical power, or environmental control rooms nor may they be in areas that may suffer flood damage or where flood damage occurred and has not been repaired. Cabinet Types Server Cabinets shall have specific dimensions to accommodate various size servers. In reference to the Dell 4210 Cabinets currently in use, dimensions of this model cabinet are 39 (100cm) tall, 24 (61cm) wide, and 39 (100cm) deep 39 (1-meter) depth is mandatory. The rack must have 42 Rack Units (RU). Figure 1 depicts server cabinets. 1

12 For network equipment and local area copper cabling, the Local Area Network (LAN) cabinets should be utilized. A common model is the 42RU Rittal Cabinet as shown in Figure 2. These cabinets provide sufficient space for the horizontal cabling patch panels and patch cords that connect into Access Layer Switches as shown in Figure 2. The dimensions are 4 (11cm) high, 32 (82cm) wide, and 3 (90cm) deep. The rack must have 42 RUs. LAN Cabinets will be equipped with thermostat controlled ventilation system (consisting of two ventilators) mounted in the top panel without loss of height units. Thermostat will be installed in front, left corner. LAN cabinets will be equipped with an 8 (20 cm) 14 W fluorescent light fixture including electronic ballast and installed top, front and centered in horizontal position without loss of height units. Cabinets should be equipped with a 19 (48 cm) telescoping convenience shelf to accommodate administrative requirements. All cabinets will be equipped with a ft (1. m) grounding bar, installed vertically against a rear leg of frame. If the RJ-4 patch panels have the ground lug positioned on the left side the ground bar will be mounted on the left leg. If the RJ-4 patch panels have the ground lug positioned on the right side the ground bar will be mounted on the right leg. Cabinets will be positioned in room in such a way as to provide front and rear access. If cabinet is a standalone cabinet, then the cabinet must have three- (3) sided access (front, rear and one side). Cabinet cable entry will be on sides, top and bottom of the cabinets. Cabinets may be bolted to the floor but is not necessary. The server racks have stabilizing platforms that must be installed. Figure 1 shows an example of front and back rack stabilizers. Placement of TRs A TR will be located on each floor at a minimum. Additional cabinets per floor may be necessary if the distances to the wall outlets exceed the maximum length of 29 ft (90m). Copper LAN cables will not be installed between floors. Physical Room Security Security locks will be provided for the TR and keys will be issued only to IT Division, Facility, and Security personnel authorized access by the IT Division Chief or required for access by fire personnel (per the NFPA). All LAN cabinet locks shall be identically keyed for management ease. The TR will be secured with a traditional lock and key system that will be keyed different than the LAN cabinet key. Cable Tray 4 (10cm) deep cable trays will loop the entire perimeter inside a TR at no less than 8 ft (244cm) above the floor. Maintain a 4 (10cm) clearance from each wall. Universal 12 (30cm) cable tray (see figure 3) will be installed at the top of the communications racks spanning the width of the room. (The use of a cable tray is ideal for installing all low voltage cables; telephone, television, security, data cables etc. at the time of installation, saving time and money. Installing a cable tray with space for future cabling also Figure 1-server cabinets Figure 2-LAN cabinet 2

13 provides an easy way to add data cables in the future without extensively disturbing the existing ceiling. Drainage Telecommunications rooms will not have floor drains in order to avoid the threat of back flooding. Telecommunication rooms shall not be located in any area that presents a high risk of water damage to the network equipment. Electrical Requirements Conditioned power will be delivered to each cabinet via an overhead cable tray. An online power backup source will support the following requirements. In all LAN and Main Distribution Frame (MDF) TRs, for each cabinet there must be installed three (3) 16 amp circuit breakers above a new server cabinet or LAN cabinet. Each circuit shall be on a different electrical phase. For the server cabinets, splice a Power Distribution Unit (PDU) power cable into each circuit with enough length to enter the cabinet in the front hole, shown in Figure 4, and reach the floor of the cabinet. Figure 4 shows three different phased 220V AC power in a splice box with the black PDU power cables splicing into the circuits. Figure, shows where the three PDU are located in the server cabinet. These PDUs are mounted on the right side facing the back of the server cabinet. Each PDU is mounted directly below each other. All cables need to reach the floor to ensure there is sufficient length. This distance may vary depending on how these circuits are mounted. Figure 3-cable trays Figure 4-front view of 16 amp circuits Figure 4-front view of 16 amp circuits Figure -top PDU locations in the server rack 3

14 From the 16 amp junction boxes, LAN cabinets will have two (2), seven-receptacle power strips, without switches. These power strips will be installed at the rear, lower half of the inner frame of the cabinet, one on the left and one on the right, and will have the receptacles facing towards the middle (not towards the front of the cabinet). Power cable will be installed in one continuous length without splicing. This rule may be waved in certain situations, but not if power cables run under a raised floor along with the facility air conditioning. Power will enter the cabinet and terminate to junction boxes mounted on the lower right side horizontal support and centered. The junction boxes will be labeled (on the box if possible) showing the distribution panel number and its fuse number. Each cabinet will be separately grounded (from the cabinet busbar) to the Telecommunications Main Ground Busbar (TMGB) or to the Telecommunications Ground Busbar (TGB) installed in the TR and connected to main building ground. Ground wires will be terminated on the TMGB or the TGB. Ground wires must be continuous with no splices. Environmental A dedicated air conditioning (A/C) unit shall be installed in each LAN, communications, and online backup system room to maintain temperature and humidity to a maximum of 68 degrees Fahrenheit (20 degrees Celsius) and 40-0 percent relative humidity. Rating of A/C units should be based on the heat generation and power consumption ratings of the installed equipment to maintain this ambient level. Fluorescent lighting shall be installed to provide 00- lux minimum at desk height. The area must be clean, temperature controlled and large enough to allow full and unimpeded access to the cabinet for installation and maintenance requirements. Grounding A communications ground (#6 AWG minimum) shall be installed from the main service entrance ground bus to each LAN and TR LAN cabinet and terminate on a copper ground plate located in the bottom rear of the cabinet. No Additional Utilities No plumbing, HVAC, or electrical conduit shall pass through, or be directly above, the Telecommunications room. In renovation projects where new Telecommunications rooms are established, all overhead utilities will be relocated out of the room. Telecommunication Room Requirements Main Distribution Frame (MDF) TR The MDF TR is a physical room located in a centralized area of the school complex used to aggregate vertical fiber optic cabling from TRs and accommodate enterprise servers, routers, and phone systems. Input power for the entire room will be provided from an online backup system. A minimum of 2-4 LAN cabinets are required to support the majority of all LAN connectivity and IT resource requirements. The Server Cabinets suitable for mounting servers while the LAN Cabinets are suitable for LAN Equipment. Additional LAN cabinets (maximum of 6) may be Figure -Middle PDU Locations in the Server Rack Figure -Bottom PDU Locations in the Server Rack 4

15 required to support site-specific requirements and future technologies. A minimum of 39 (1m) clearance around the entire LAN cabinet and unrestricted access to all cabinet doors and side panels is necessitated. In situations that present space limitations, a maximum of two cabinets may be bolted together with three sides of each cabinet still accessible as seen in Figure 6. Local Area Network (LAN) TR Physical rooms located throughout a building that contain LAN cabinets required to connect horizontal copper cabling between patch panels and room wall outlets. Each TR will connect to the MDF via fiber optic cabling. At minimum, one TR shall be allocated per building per floor. In multi-level buildings, it is feasible to configure TRs on top of each other for ease of maintenance and future upgrades. Adequate clearance around the entire LAN cabinets and unrestricted access to all cabinet doors and side panels is necessitated. Vertical Cable Infrastructure - Fiber Optics Renovation projects or additions to existing LAN infrastructure At a minimum, backbone network cabling shall consist of one (1) 4-strand, 62./12-micron multimode fiber (MMF) optic cable terminated in a fiber optic distribution panel with ST connectors and one (1) 8-strand 9/12-micron single-mode fiber (SMF) optic cable terminated in a fiber optic distribution panel with SC connectors. The installation of MMF in renovation projects allows for backward compatibility with existing legacy networks already using this technology. SMF optic cabling provides more efficient Figure 6-top view example of MDF TR Figure 6-top view example of MDF TR Figure 7-top view example of LAN TR Figure 7-top view example of LAN TR

16 data throughput, increased bandwidth capacity, and greater distance support in comparison to MMF optic cable. Fiber optic cabling shall meet all applicable EIA/TIA 68 B.3 standards capable of supporting 1000Base-T and 10GBASE-T deployments conforming to IEEE 802.3ae and 802.3an. New Construction MILCON Projects At a minimum, backbone network cabling shall consist of one (1) 12-strand, 9/12-micron singlemode fiber (SMF) optic cable terminated in a fiber optic distribution panel with SC connectors. Fiber optic cabling shall meet all applicable EIA/TIA 68 B.3 standards capable of supporting 1000Base-T and 10GBASE-T deployments conforming to IEEE 802.3ae and an. Installation Guidelines: Install plenum-rated cabling where applicable. Fiber optic patch panels shall be located in the upper portion of the LAN cabinet. Single-mode fiber will be terminated with SC connectors Multi-mode fiber will be terminated with SC connectors. Provide 48 (122cm) service loop for fiber optic cables in each LAN cabinet. Excess cable shall be located neatly in cable tray. Machine printed labels will be provided for fiber optic patch panel identification. Fiber optic patch panel labeling will include type, cable number, count, and cable size at the terminal points. See Table 1 for an example of labeling fiber cabling. All fiber optic cabling will be certified to EIA/TIA 68 B.3 standards. Test report data must be presented, unaltered, in a common electronic format prior to acceptance of horizontal cabling infrastructure. FOC 01, 1-12, 12SM FM: BLDG, TR1 TO: BLDG, TR2 FOC 01, 1-6, 6MM FROM: BLDG, TR1 TO: BLDG 70, TR10 Table 1-examples of labeling fiber cabling Horizontal Network Cabling The category of cabling used must be determined by the purpose and project requirements. For renovation projects or addition of LAN drops in existing facilities, the same type of copper cabling should be used. In all new constructions, Cat 6 Class E cabling is the standard horizontal cable. The cabling shall be installed in continuous, un-spliced, lengths between the LAN cabinet patch panel and the classroom or office wall outlet. It cannot exceed 29 ft (90m). All cabling installations shall conform to applicable Electrical Code, local regulations, and EIA/TIA 68 B.2 standards. Type Speed Information Cat. E (Class D) 10/100/1000 MbE Maximum cable distance 90m, minimum of 100Mhz of bandwidth Cat. 6 (Class E) 10/100/1000 MbE/10GbE Table 2-copper cable specifications Maximum cable distance 90m, minimum of 100Mhz of bandwidth Installation Guidelines Each LAN cabinet has a maximum capacity of 216 drops. Note that this includes all data, telephone, and wireless AP drops. Install plenum-rated cabling where applicable. Copper patch panels will be located in the upper portion of the LAN cabinet and will be separated by 1 RU of space. In this 1 RU of space, Cable guides should be installed to keep acceptable cable management standards. Cables shall run parallel or at right angles to the building structure and shall not be installed diagonally across ceiling spaces. Cables shall be supported by J-Hooks or equivalent, installed at intervals not exceeding ft (12cm) between supports, and be permanently anchored to building structure or building surfaces. Cabling shall not be supported from ductwork, water or waste piping, electrical conduits, suspended ceiling supports, or be supported from the ceiling suspension system. Provide 24 (61cm) service loop for cables at each LAN cabinet. Excess cable shall be located neatly in cable tray. Provide 12 (30cm) service loop at each LAN wall outlet. Excess cable shall be located in wall, conduit, or ceiling. Machine printed labels will be provided for copper patch panel, media, and the wall outlet identification. Copper patch panel labeling will include TR number or room number, patch panel number, and port number. 6

17 Wireless Network Wireless technology requires additional LAN drops at ceiling level to support Wireless Access Points (APs). These APs provide network connectivity for approximately computers over a limited range of distance. Based on physical area, building structure properties, and number of users, DoDDS-E network administrators determine the placement of wireless access points throughout the school. 4.1 Wireless Installation Power Power to these APs is provided by the network equipment through Power over Ethernet (POE) switches. No additional power requirement is needed. Indoor Installation The best practice is to install a minimum of one drop in the center of the room above the ceiling. Rooms where these drops will be located will be coordinated with AE firms during design and clearly annotated on as-built construction drawings. This will allow the network installers to easily locate the drop and give them the flexibility to install the AP anywhere on the ceiling to provide maximum effectiveness and signal quality to the users. The installation team is required to mark the location of ceiling LAN drops on the LAN box and drop ceiling (if applicable). Outdoor Installation Mounting outdoor wireless equipment needs to be weatherproof but does not require the LAN drop to be located outside the building. The antenna cables are typically long enough to connect from the AP to the external antenna. The antenna must either be able to withstand the outdoor elements or be enclosed in such a manner to withstand the elements. Protective Covering In gymnasiums and multipurpose rooms, a protective enclosure suitable to protect the wireless network equipment. The protective enclosure shall be designed to protect the access point from stray objects while still allowing adequate signal levels to the clients. Cable Termination Wireless access point cabling shall be terminated in a patch panel separate from normal wired connections and should not exceed more than 24 ports per LAN cabinet. It is the Department of Defense (DoD) standard to keep the wireless network physically and logically separated from the data network due to security risks associated with wireless. This is the most effective and robust design along with the ability to add future security equipment to protect network. DoD Wireless Policies Wireless technologies that are integrated or connected to DoDEA networks must comply with DoD Directive and DoD Instruction Wireless technologies under consideration for access to DoDEA networks and information are required to undergo vulnerability testing, complete the Interim DoD IA Certification and Accreditation Process Guidance. DoD Information Assurance Certification and Accreditation Process (DIACAP), previously known as the Department of Defense Information Technology Security Certification and Accreditation Process (DITSCAP), must meet DoD standards and security requirements, and be approved by the DoDEA Chief Information Officer (CIO). Activities considering wireless technologies for use in a test or educational setting must ensure that there is physical and logical separation from any DoDEA network, in addition to, physical and logical separation from any associated DoD networks, and that those technologies do not process unclassified, sensitive, or privacy information. DoD has provided guidance for wireless technology in DoD Directive Voice Over Internet Protocol (VoIP) System The majority of current school LANs will support VoIP technologies without a major upgrade in cable infrastructure. The VoIP phones implemented throughout DoDDS-E, for example, have an additional port to allow a computer access to the network. The phone power is supported by Power Over Ethernet (POE) technology that originates from the network equipment in the telecommunication rooms. It is always recommended to survey a building considering VoIP implementation to best determine additional infrastructure requirements. Such additional requirements may include infrastructure upgrades for wireless networks, IP based overhead paging speakers, and phone trunk connections. Please consult the DoDEA IT Division for further guidance on VoIP requirements. 7

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120 DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data

More information

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Newark, Delaware Architectural Engineering Senior Thesis Portfolio Telecommunications System Design The represents the advancement of solar design in our world today. The building itself is an example of this. A Headquarters this dedicated to moving into the future should

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS May 1, 2016 Reviewers should - Be aware that these checklists are not allinclusive but only provide important review items. Reviewers should - Use Checklists

More information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017. Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Classroom WiFi Network Infrastructure Plan

Classroom WiFi Network Infrastructure Plan Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to

More information

Tier IV Standards as Specified in the TIA 942 Document

Tier IV Standards as Specified in the TIA 942 Document S No Architectural Proximity of visitor parking to data 18.3 m / 60 ft minimum separation with physical barriers to prevent vehicles from 1 center perimeter building walls driving closer 2 Building Construction

More information

Cabling a Data Center to TIA-942 Standard

Cabling a Data Center to TIA-942 Standard Cabling a Data Center to TIA-942 Standard BICSI 2006 Winter Conference Wednesday, January 25 th 2006 at 9:15 am Gary J. Bernstein, RCDD HellermannTyton Corporation Agenda Overview of TIA-942 Data Center

More information

f) Telecommunications Equipment Rooms

f) Telecommunications Equipment Rooms SECTION 270000 - COMMUNICATIONS PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification

More information

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs SECTION 13744 COMPUTER NETWORK WIRING SYSTEMS FOR PLCs NOTE TO SPECIFIER: This section applies to primary learning centers only. PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete computer network

More information

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES University of California, Riverside Computing and Communications April XX, 2001 R1V6 TABLE OF CONTENTS Introduction and Background...3 Outside

More information

Cabinet Location Plan FIG.01. Cabinet Symbol Key. Air Handler. Air Handler SAN disk storage. SAN disk storage. option B. Not To Scale.

Cabinet Location Plan FIG.01. Cabinet Symbol Key. Air Handler. Air Handler SAN disk storage. SAN disk storage. option B. Not To Scale. Cabinet front face - 09 Data Center Storage / Fit-Up Square Feet Square Meters Up Cabinet Symbol Key A Network Row A Network Substation B Server Cabinet A A A A4 A A6 A7 A8 A9 FIG.0 Data Center Square

More information

Los Angeles Community College District Design Standards

Los Angeles Community College District Design Standards LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure

More information

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6 Network Construction Guide Specification Telecommunications Infrastructure Standards 11-16-2018 V 2.6 Springfield Public Schools R12 Prepared by: Approved by: Released by: Springfield Public Schools R12

More information

LACCD IT Design Standards

LACCD IT Design Standards LACCD IT Design Standards March 1 2009 This document establishes a uniform standard for the design of IT Structured Cabling for LACCD. It ensures a secure, consistent, robust system with physical and low-voltage

More information

FIBER OPTIC HARDWARE STEVE PAULOV

FIBER OPTIC HARDWARE STEVE PAULOV C H A P T E R 7 FIBER OPTIC HARDWARE STEVE PAULOV The main purpose for hardware is to protect and organize splice and termination points. Hardware can be divided into two categories; indoor and outdoor.

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

Data Cabling / Low Voltage Technology Specifications

Data Cabling / Low Voltage Technology Specifications P19-02- Forsyth County Schools Data Cabling / Low Voltage Technology Specifications 1. General requirements 1.1 On premise connectivity All building closets (IDF) aside from the main closet (MDF) shall

More information

ANSI/TIA/EIA-568-B Cabling Standard NOTE

ANSI/TIA/EIA-568-B Cabling Standard NOTE 95 ANSI/TIA/EIA-569-A Though the ANSI/TIA/EIA-568-B Standard describes the subsystems of a structured cabling system, the TIA has published a more thorough document called ANSI/TIA/EIA-569-A Commercial

More information

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...

More information

Data Center Design and the ANSI/TIA-942 Standard

Data Center Design and the ANSI/TIA-942 Standard Data Center Design and the BICSI Regional Meeting Ellicott, MD Rick Foster RCDD,TLT Communications Infrastructure Group July 27, 2006 What is ANSI/TIA-942? Published by TIA in April 2005 Telecommunications

More information

Communications. UNM IT/Telecommunications Guide Specification Communications

Communications. UNM IT/Telecommunications Guide Specification Communications The material below covers specific information we definitely want to be included in the contract documents and may not be a completed specification section. This material is to be highlighted in your preliminary

More information

General. Exterior Cameras. Camera Towers

General. Exterior Cameras. Camera Towers CAMERAS General This section explains the requirements for interior and exterior cameras. Two basic types of training ranges have cameras: Urban Ranges and Instrumented Training Ranges. Refer to the standard

More information

The six major components of a structured wiring system are:

The six major components of a structured wiring system are: OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC 5-, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC 5-,

More information

Legal Aid Ontario IT Standards & Guidelines for LAO Branch and Clinic Offices

Legal Aid Ontario IT Standards & Guidelines for LAO Branch and Clinic Offices Legal Aid Ontario IT Standards & Guidelines for LAO Branch and Clinic Offices Prepared by: LAO IT-Operations Group July 8, 2015 Revision: 1.1 Table of Contents 1. Introduction... 2 1.1 Functions of a Server

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Date: Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of stations meets DD 9, applicable

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site preparation guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TIA/EIA 568A Sub-system HORIZONTAL CABLING

TIA/EIA 568A Sub-system HORIZONTAL CABLING TIA/EIA 568A Sub-system HORIZONTAL CABLING Horizontal Cabling WA 100(120)Ω CAT 3 TP TP 100(120)Ω CAT 5 150Ω STP-A 62.5(50)/125µ FIBER HC/FD WA Horizontal Media Considerations UTP/FTP Consider bandwidth,

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to

More information

SECTION 12.0c CONSTRUCTION SYSTEMS AND ASSEMBLIES STANDARDS AND GUIDELINES ADDENDUM C: CLASSROOMS AND AUDITORIA BEST PRACTICES

SECTION 12.0c CONSTRUCTION SYSTEMS AND ASSEMBLIES STANDARDS AND GUIDELINES ADDENDUM C: CLASSROOMS AND AUDITORIA BEST PRACTICES SECTION 12.0c CONSTRUCTION SYSTEMS AND ASSEMBLIES STANDARDS AND GUIDELINES ADDENDUM C: CLASSROOMS AND AUDITORIA BEST PRACTICES INTRODUCTION The following list of classroom and auditorium features was compiled

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

ARCHITECTURAL GUIDELINES FOR INSTRUCTIONAL TECHNOLOGY

ARCHITECTURAL GUIDELINES FOR INSTRUCTIONAL TECHNOLOGY ARCHITECTURAL GUIDELINES FOR INSTRUCTIONAL TECHNOLOGY Introduction A classroom is measured by its effectiveness in facilitating the exchange of information. The following general guidelines have been developed

More information

Information Services IT Security Policies L. Network Management

Information Services IT Security Policies L. Network Management Information Services IT Security Policies L. Network Management Version 1.1 Last updated: 11th August 2010 Approved by Directorate: 2nd July 2009 Review date: 1st August 2011 Primary owner of security

More information

AT&T Switched Ethernet Service SM

AT&T Switched Ethernet Service SM Site Preparation Guide AT&T Switched Ethernet Service SM December 2016 2016 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks

More information

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T

More information

A Complete Floor Box System for Concrete

A Complete Floor Box System for Concrete A Complete Floor Box System for Concrete Leviton has it all. From the floor box itself to the devices inside, our system delivers superior electrical power, AV and networking solutions. Delivering The

More information

Yuna Shin Leviton Network Solutions

Yuna Shin Leviton Network Solutions Y Yuna Shin Leviton Network Solutions Presenter Bio Yuna Shin Senior Product Manager, Copper Leviton Network Solutions Bothell, WA U.S.A. Manages Leviton's extensive selection of Category 6A, 6, and 5e

More information

Communications Site Installation R56 Installer and Communications Site Inspector/Auditor version COMPETENCY REQUIREMENTS

Communications Site Installation R56 Installer and Communications Site Inspector/Auditor version COMPETENCY REQUIREMENTS Communications Site Installation R56 Installer and Communications Site Inspector/Auditor version COMPETENCY REQUIREMENTS The following is a listing of each topic considered necessary to be included in

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS SECTION 27 11 19 COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section specifies the products and installation of communications termination blocks and patch panels

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

CCBC is equipped with 3 computer rooms, one at each main campus location:

CCBC is equipped with 3 computer rooms, one at each main campus location: Policy: Computer Room Procedures Policy: Draft 12/14/2009 1.0 Purpose The purpose of this document is to establish procedures for the Community College of Baltimore County (CCBC) Information Technology

More information

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Emerging technologies dictate that it is no longer allowable to simply integrate various manufacturers components into a

More information

SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT. ITS Telecommunications Standards - Specifications Manual for Construction and Renovations

SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT. ITS Telecommunications Standards - Specifications Manual for Construction and Renovations SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT ITS Telecommunications Standards - Specifications Manual for Construction and Renovations Page 1 of 67 TABLE OF CONTENTS UNC Charlotte Information Technology

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

XBR V4 INSTALLATION AND USER GUIDE

XBR V4 INSTALLATION AND USER GUIDE XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson

More information

FACILITY COMPONENTS - MIDDLE SCHOOL

FACILITY COMPONENTS - MIDDLE SCHOOL SITE AREAS Parking and Access - Buses 4.0 2.0 0.59 Parking and Access - Serv. / Delivery 3.0 1.0 0.22 Parking and Access - Staff 4.0 3.0 0.89 Parking and Access - Visitors 4.0 3.0 0.89 Parking and Access

More information

2 Telecommunications Data Center Facility Requirements

2 Telecommunications Data Center Facility Requirements Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

Site Preparation for ClearCube Installation. Rev. F

Site Preparation for ClearCube Installation. Rev. F Site Preparation for ClearCube Installation Rev. F EXECUTIVE SUMMARY Because of the centralized nature of the ClearCube architecture, installation of the system requires a certain degree of site preparation.

More information

Business Customer Demarcation Information

Business Customer Demarcation Information Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business data customers and services. 1. What is a

More information

How You Can Optimize Passive Optical LAN Through Structured Cabling

How You Can Optimize Passive Optical LAN Through Structured Cabling How You Can Optimize Passive Optical LAN Through Structured Cabling Author: Stephane Bourgeois Director Technology Strategy Table of Contents Overview 1 What is POLAN? 1, 2 Deploying a POLAN 2 The Benefits

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

Telecommunications Structured Cabling Systems

Telecommunications Structured Cabling Systems Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major

More information

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express AT&T Virtual Private Network Service (VPN) and AT&T VPN Express Site Preparation Guide 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered

More information

Wire Communications Design jfm 07. An Inside Look at Outside Plant

Wire Communications Design jfm 07. An Inside Look at Outside Plant An Inside Look at Outside Plant BICSI Region Meeting 2007 Agenda What is CO-OSP? A close look at the 758-A standard Available Resources What is CO-OSP? Customer Owned Outside Plant Telecommunications infrastructure

More information

Pre-installation Manual

Pre-installation Manual Pre-installation Manual Rinse Gum Unit 85-125-165 Pre-installation Manual Rinse Gum Unit 85-125-165 T11018 Edition BA, March 2006 This book has part no 51477 0-2 Introduction Part 0: Introduction This

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD9, applicable TC -, and CEHNC Design Guide 0-- Oriented to face firing line or firing positions/points B. Roads-Service, Lanes Number of lanes meets DD 9, applicable TC -,

More information

RFP Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service

RFP Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service RFP 2017 845 Annex A Terms of Reference UNHCR HQ Data Centre Colocation Service Version 1 Contents Project objectives... 1 Background... 1 Scope... 1 Timeframe and Cost... 4 Stakeholders, roles and responsibilities...

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum) Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3

More information

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC. Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC. 1.01 General Requirements This section details general requirements for plenum sound masking installations. 1.1 Contract

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS PART 1 - GENERAL SECTION 270500 - COMMON WORK RESULTS FOR COMMUNICATIONS 1.1 RELATED SECTIONS A. All division 27 work shall, in addition to all division 1 specification sections, comply with all of the

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

This manual describes how to prepare a site for the CTL 9712 DPS 7000 Integrated Library Unit (ILU).

This manual describes how to prepare a site for the CTL 9712 DPS 7000 Integrated Library Unit (ILU). January 1997 7 Preface PURPOSE OF THIS MANUAL This manual describes how to prepare a site for the CTL 9712 DPS 7000 Integrated Library Unit (ILU). It gives the specific site requirements for the following

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

Data Centre Security. Presented by: M. Javed Wadood Managing Director (MEA)

Data Centre Security. Presented by: M. Javed Wadood Managing Director (MEA) Data Centre Security Presented by: M. Javed Wadood Managing Director (MEA) EPI history and global locations UK origin, 1987 Singapore office, 1999 9 EPI offices worldwide Global partner network spanning

More information

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies

More information

BROWARD COUNTY AVIATION DEPARTMENT INSIDE PLANT INFRASTRUCTURE SPECIFICATIONS

BROWARD COUNTY AVIATION DEPARTMENT INSIDE PLANT INFRASTRUCTURE SPECIFICATIONS BROWARD COUNTY AVIATION DEPARTMENT INSIDE PLANT INFRASTRUCTURE SPECIFICATIONS All noted standards apply to the current revisions applicable at the time of construction or intended construction. NO SUBSTITUTIONS

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

QUICKSTART INSTALLATION INSTRUCTIONS

QUICKSTART INSTALLATION INSTRUCTIONS WEGENER i8640 DIGITAL AUDIO SERVER QUICKSTART INSTALLATION INSTRUCTIONS This satellite receiver has been provided for the reception of MRN, WestwoodOne or Compass Sports. Once installed, please contact

More information

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet Reference: ZD23 Version: 1.1 Issue date: 15 May 2014 Contents 1 Scope... 3 2 Deer Park Terminal

More information

Proposed Changes (minor changes from 2004 standards) for: Classroom Technology Standards Shoreline Community College

Proposed Changes (minor changes from 2004 standards) for: Classroom Technology Standards Shoreline Community College 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Proposed Changes (minor changes from 2004 standards) for: Classroom Technology

More information

Multi-Purpose Building

Multi-Purpose Building Multi-Purpose Building Description and Goals Multi-Purpose Rooms should be large enough to accommodate 400-500 students. The main multi-purpose will be acoustically designed primarily for musical performances

More information

Network+ Guide to Networks 7 th Edition

Network+ Guide to Networks 7 th Edition Network+ Guide to Networks 7 th Edition Chapter 4 Structured Cabling and Networking Elements 2016 Cengage Learning. May not be scanned, copied or duplicated, or posted to a publicly accessible website,

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

V-Built Custom Preconfigured Solutions

V-Built Custom Preconfigured Solutions WWW.SIEMON.COM V-Built Custom Preconfigured Solutions 8 One Part Number, One Price Ready to Roll Available with any Siemon cabinet, rack or enclosure, Siemon s V-Built Custom Preconfigured Solutions are

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Hardened PoE Ethernet Switch

Hardened PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation

More information

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions Digital Building Solutions Run a Smart Workplace Introducing the Digital Building Maximize efficiency and productivity Enhance infrastructure flexibility & network security Reduce installation and operating

More information

Copper Riser And Intrabuilding Cabling

Copper Riser And Intrabuilding Cabling Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable

More information

WPS Building Committee Ai3 Architects, LLC Daedalus Projects, Inc October 17, 2018

WPS Building Committee Ai3 Architects, LLC Daedalus Projects, Inc October 17, 2018 Watertown Elementary Schools Building Project DesignWatertown WPS Building Committee Ai3 Architects, LLC Daedalus Projects, Inc October 17, 2018 Schools Project Website: www.watertownschoolsproject.com

More information