TIA/EIA 568A Sub-system HORIZONTAL CABLING
|
|
- Tracy Wiggins
- 5 years ago
- Views:
Transcription
1 TIA/EIA 568A Sub-system HORIZONTAL CABLING
2 Horizontal Cabling WA 100(120)Ω CAT 3 TP TP 100(120)Ω CAT 5 150Ω STP-A 62.5(50)/125µ FIBER HC/FD WA
3 Horizontal Media Considerations UTP/FTP Consider bandwidth, architecture and budget for this one. Shielded Twisted Pair fiber
4 Horizontal Media Media Type Conductor Construction Bandwidth Connector Type 100Ω/120Ω CAT 3 UTP 24 AWG Solid (patch - stranded) up to 16 MHz 8-Position IDC 100Ω/120Ω CAT 5 UTP 24 AWG Solid (patch - stranded) up to 100 MHz 8-Position IDC 150Ω STP-A 22 AWG Solid (patch - 26 AWG stranded) up to 300 MHz 4-Position Data OPTICAL FIBER 62.5/125µm Multi-mode 50/125µm Multi-mode up to 500 MHz-km Duplex 568SC SC-D Enhanced CAT 5 CAT6 (250 MHz) CAT 7 (600 MHz)
5 Horizontal Cabling CONNECTORS UTP/FTP PAIR 2 8-POSITION MODULAR JACK CAT 3 CAT 4 CAT 5 PAIR 3 PAIR 1 PAIR T 568 A T3 (WHT/GRN) R3 (GRN/ WHT) T2 (WHT/ORG) R1 (BLU/ WHT) T1 (WHT/BLU) R2 (ORG/WHT) T4 (WHT/BRN) R4 (BRN/ WHT) PAIR 3 PAIR 2 PAIR 1 PAIR POSITION MODULAR PLUG T 568 B (AT&T 258A) T2 (WHT/ORG) R2 (ORG/ WHT) T3 (WHT/GRN) R1 (BLU/ WHT) T1 (WHT/BLU) R3 (GRN/WHT) T4 (WHT/BRN) R4 (BRN/ WHT)
6 Horizontal Cabling CONNECTORS FIBER OPTIC DUPLEX SC CONNECTORS 62.5/125 FIBER 568 SC BULKHEAD CONNECTOR
7 Horizontal Bandwidth and Media Network Type Signaling Bandwidth Cable Pairs Minimum Media 10 BASE-T 10 MHz 2 CAT 3 Token Ring 4MHz/16MHz 2 CAT 3 100BASE-TX MHz 2 CAT Mbps ATM 77.5 MHz 2 CAT BASE-T 62.5 MHz 4 CAT 5? 1.2 Gbps ATM???
8 Horizontal Distances 90 m 6 m 3 m
9 Horizontal Pathways UTP/FTP INSTALLATION PRACTICE Cable, connectors, and patch cords of same category or higher. Untwist of cable pairs <13 mm (0.5 in.) for category 5 applications. Maximum pulling tension for 4 pair 24 AWG (0.5 mm) should not exceed 110 N (25 lbf). Elimination of cable stress caused by tension in suspended cable runs and tight clinched cable bundles (cable ties). Bend radius > four times the cable diameter for 4 pair UTP and > ten times the cable diameter for multi-pr UTP cable. FTP cable shield must be grounded to the Telecommunication Grounding Busbar.
10 Horizontal Pathways FIBER OPTIC INSTALLATION PRACTICE Maximum Pulling Force Should Be Marked on Cable Reel by Manufacturer Average pull tension is 200 lbs. No less than 20 times the diameter when pulling cable No less than 10 times the diameter when placed Cabling Must Be Polarized Cabling Shall Be Tested for Polarity and Attenuation
11 Telecommunications Outlet Elevation
12 AMP Angled Faceplate With Shutter Cover (UK version)
13 Telecommunications Outlet Pathway Elevation
14 Telecommunications Closet TYPICAL FLOOR LAYOUT Area B 530 m (5,300) ft Telecommunications Closet B Telecommunications Closet C Area C 530 m (5,300) ft 7 5 mm Conduit (3") Core Area 7 5 mmconduit (3") Area A 800 m (8,000) ft Telecommunications Closet A
15 Telecommunications Closet TYPICAL CLOSET DESIGN 100mm (4") mm (1-3") Max Typical Conduit Sleeve Through Floor Ladder Rack (Above Relay Racks) Equipment Power 900mm (36")x1800mm (72") Door With Lock Externally Opened Only Equipment Power Power Bar Rear 19" Equipment Rack Front Instrument Power 1m (39" Plus) Aisle (Equipment Repair and Install) Ceiling Fluorescent Fixture Front Power Bar Rear 19" Equipment Rack 20mm (3/4 ) Plywood Backboard Distribution Facilities to Offices Ceiling Level Ladder Rack 3x100mm (4") Ceiling Fluorescent Fixture Sleeves (Minimum) Ceiling Level Ladder Rack Ceiling Fluorescent Fixture Closet Interconnecting Conduit (Fire Stopped) Distribution Facilities to Office 20mm (3/4 ) Plywood Backboard
16 Telecommunications Closet Elevation
17 Telecommunications Closet Rack Elevation
18 Nanyang Primary School 19 Rack Cabinets Layout - LAN Room 1 RACK 1 With Full Load Points 42RU 41RU 40RU 39RU 38RU 37RU 36RU 35RU 34RU 33RU 32RU 31RU 30RU 29RU 28RU 27RU 26RU 25RU 24RU 23RU 22RU 21RU 20RU 19RU 18RU 17RU 16RU 15RU 14RU 13RU 12RU 11RU 10RU 9RU 8RU 7RU 6RU 5RU 4RU 3RU 2RU 1RU APC 3000 APC 3000 L1R1-CS01 L1R1-ES0 1 L1R1-ES0 2 L1R1-ES0 3 L1R1-ES0 4 L1R1-ES0 5 L1R1P01 L1R1P02 L1R1P03 L1R1P04 L1R1P05 L1R1P06 L1R1P07 L1R1P08 L1R1-UPS2 L1R1-UPS1 UPS to Equipm ent L1 R1- UPS2 Rack1 L1 R1- CS 01 L1 R1-ES01 L1 R1-ES02 L1 R1-ES03 L1 R1-ES04 L1 R1-ES05 Unit Wt(Kg) / Unit Weight FTP Points per Rack Jack Panel Cable Management Fiber Junction 2 2 3COM CB COM SSII SU30005U (UPS) " Rack Total Weight L1R1-BP2 Battery Pack L1R1-BP1 Battery Pack 1 Rack Unit (RU) = mm (1.75 )
19
20 Horizontal Cabling Floorplan
21 Horizontal Exercise CABLE LENGTH CALCULATION LL SL ( SL + LL+ 4CH X # WS ) + 15% 2
22 Project Name Contact Name [Company Name] [Address 1] [Address 2] [Customer Name] Phone # [Customer Phone #] * Markup % Labor Rate Mfg P/N Description Qty Cost $ U/M X-Cost $ Marku p % X-Price $ 0 Labor Rate Labor Hrs X-Labor $ Line Total $ /4 CAT5 GRAY PLENUM CABLE (VOICE) 113 $ M/FT. $22, /4 CAT5 WHITE PLENUM CABLE (DATA) 108 $ M/FT. $21, PORT FLUSH FACEPLATE GRAY 250 $1.41 EA. $ PORT FUNITURE FACEPLATE GRAY 350 $1.76 EA. $ BLANK INSERT GRAY 1200 $0.24 EA. $ AMP110W SEMTRON WALL PHONE FACEPLATE 24 $1.95 EA. $ RJ45 CAT5 568A INSERT ORANGE 600 $4.15 EA. $2, RJ45 CAT5 568A INSERT GRAY 624 $4.15 EA. $2, /300 PAIR WIRING BLOCK 10 $24.10 EA. $ /4 PAIR CONNECTING BL0CK 624 $0.40 EA. $ DESIGNATION STRIP HOLDER 60 $0.25 EA. $ CABLE MANAGEMENT RING 10 $7.00 EA. $ PORT CAT5 568A PATCH PANEL 15 $ EA. $2, " HORIZONTAL MANAGEMENT PANEL 20 $41.00 EA. $ CABLE SUPPORT BAR 20 $11.40 EA. $ PRO SYSTEM RACK W/MANAGEMENT 5 $ EA. $2, CADDY MP1 MP1 CUT-IN RING 149 $0.56 EA. $ FT. CAT5 PATCH CORD BLACK BOOT 200 $3.51 EA. $ X-Cost $ X-Price $ Hours X-Labor $ Line Total $ Line Totals
23 Underfloor Systems Horizontal Pathways Underfloor Duct Cellular Floor Access Floor Systems Conduit Systems Cable Trays and Wireways Ceiling Pathways Perimeter Pathways Miscellaneous Pathways
24 Horizontal Pathways UNDERFLOOR DUCT Concrete Two Level Flushduct Multichannel Raceway TC Junction Box Feeder Duct Distribution Duct
25 Horizontal Pathways CELLULAR FLOOR TYPES Steel Concrete TC Power Trough Data Voice
26 Horizontal Pathways ACCESS FLOOR TYPES Stringered Free Standing Cornerlock TC MINIMUM HEIGHTS General Office Areas = 150mm (6") Computer Area or Plenum = 300mm (12")
27 Horizontal Pathways CONDUIT SYSTEMS TYPES Metallic Tubing Rigid Metal Rigid PVC Pull Box TC - Length no more than 30 meters or contain more than two 90 o bends
28 Horizontal Pathways CEILING PATHWAYS Plenum Space TC Suspended Ceiling Utility Columns
29 Horizontal Pathways PERIMETER PATHWAYS TYPES Surface Raceway Recessed Raceway Molding Raceway Multichannel Raceway 10 x 10
30 Horizontal Pathways CABLE TRAYS AND WIREWAYS TYPES Ladder Cable Tray Solid-Bottom Cable Tray Ventilated or Trough Cable Tray Wireway Channel Cable Tray
31
BACKBONE CABLING. Structured Cabling Systems. Entrance Closet. Telco Closet. Intermediate Cross Connect. Telco Closet. Main Cross Connect.
Structured Cabling Systems BACKBONE CABLING Bldg 3 Entrance Closet Telco Closet Bldg 2 Telco Closet Intermediate Cross Connect Main Cross Connect Backbone Cabling ER HC/FD UTP STP-A Optical Fiber HC/FD
More informationCOMPUTER ENGINEERING AND INFORMATION TECHNOLOGY DEPARTMENT NETWORK LABORATORY. Ethernet Cabling
Experiment number :(1) Ethernet Cabling Introduction:- The EIA/TIA (Electronic Industries Association and the newer Telecommunications Industry Alliance) is the standards body that creates the Physical
More informationTarleton State University. Specifications
Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication
More informationCOMPUTER NETWORK WIRING SYSTEMS FOR PLCs
SECTION 13744 COMPUTER NETWORK WIRING SYSTEMS FOR PLCs NOTE TO SPECIFIER: This section applies to primary learning centers only. PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete computer network
More informationE. Numbering and Labeling Pathway components. In general, pathway components are not labeled.
27 05 53 Identification (Labeling) for Communications Systems (Revision date: 3/6/13) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are part
More informationThe six major components of a structured wiring system are:
OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.
More informationNetwork Construction Guide Specification Telecommunications Infrastructure Standards V 2.6
Network Construction Guide Specification Telecommunications Infrastructure Standards 11-16-2018 V 2.6 Springfield Public Schools R12 Prepared by: Approved by: Released by: Springfield Public Schools R12
More informationLos Angeles Community College District Design Standards
LACCD Facilities Design Standards - Structural Cabling and Telecommunications Room Facilities Ver Approved: DTC February 0, 0 LACCD has developed the following Districtwide standard for IT infrastructure
More informationOffice of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO
Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note
More informationGovernment of Prince Edward Island Structured Cabling Standards August 24, 2009
Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Emerging technologies dictate that it is no longer allowable to simply integrate various manufacturers components into a
More informationComputer Network Design Guide Existing Systems 1 / 6
COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should
More informationAMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo
AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM Welcome!!! Instructor : Nicholas Yeo AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM Welcome!!! 2 Standards ISO CENELEC AS/NZS ANSI IEC CSA TIA EIA EN50173 AS/NZS
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationOMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE
OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.
More informationTarget Interface / Construction Compliance Inspection Checklist
TES A. Roads-Service, Lanes Common Items Trails and service roads provide adequate access to buildings for maintenance B. Testing Results-provided to the local government construction representative Data
More informationContents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06
Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...
More informationREFERENCE T3 R3 T2 R1 T1 R2 T4 R4 WHT GRN T2 R2 T3 R1 T1 R3 T4 R4 WHT
P O L A R I Z A T I O N G L O S S A R Y & A L P H A N U M E R I C REFERENCE S Y S T E M A P P L I C A T I O N S C A B L I N G S T A N D A R D S 1 2 3 4 5 6 7 8 T3 R3 T2 R1 T1 R2 T4 R4 WHT GRN GRN WHT ORG
More informationA. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
UDIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
More informationv2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.
Changes in v2.6: v2.5 was updated May 10, 2016. v2.6 is an updated copy from March 1, 2017. Modifications to 4. Horizontal Pathways section with feedback incorporated from UofA Facilities and Operations
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationUNIVERSITY OF CALICUT (Purchase Division)
No. 12831/PURCHASE-ASST-A1/2013/CU UNIVERSITY OF CALICUT (Purchase Division) Calicut University. P.O., Dated, 07.06.2013. TENDER NOTICE Sealed and competitive tenders are invited for the installation of
More informationClassroom WiFi Network Infrastructure Plan
Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to
More informationINTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES
INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES University of California, Riverside Computing and Communications April XX, 2001 R1V6 TABLE OF CONTENTS Introduction and Background...3 Outside
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationSECTION COMMON WORK RESULTS FOR COMMUNICATIONS
PART 1 - GENERAL SECTION 270500 - COMMON WORK RESULTS FOR COMMUNICATIONS 1.1 RELATED SECTIONS A. All division 27 work shall, in addition to all division 1 specification sections, comply with all of the
More informationElement Z General Design Requirements Owner Standards and Other Requirements
Element Z General Design Owner and Other IS Network Services & PART 1 - General Information...2 1.01 Background...2 1.02 Scope...2 1.03 Additions, changes, testing, and acceptance...2 1.04 Special cases
More informationCategory 5e Solutions
Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction
More informationCOMMON WORK RESULTS FOR COMMUNICATIONS
SECTION 270500 - COMMON WORK RESULTS FOR COMMUNICATIONS PART 1 - GENERAL 1.1 RELATED SECTIONS A. All division 27 work shall, in addition to all division 1 specification sections, comply with all of the
More informationInterconnect Product CATALOG Q700
onents.com Interconnect Product CATALOG Q700 Quest Network Quest Network Warranty Products Warranty Que st Technology International Inc., carries a LIFETIME warranty on all Category- Rated link components
More informationData Cabling / Low Voltage Technology Specifications
P19-02- Forsyth County Schools Data Cabling / Low Voltage Technology Specifications 1. General requirements 1.1 On premise connectivity All building closets (IDF) aside from the main closet (MDF) shall
More informationThe Anixter Standards REFERENCE GUIDE
The Anixter Standards REFERENCE GUIDE A reference guide to: ANSI/TIA/EIA-568-A ANSI/TIA/EIA-569-A ANSI/TIA/EIA-606 ANSI/TIA/EIA-607 Now Including: Current Telecommunications Systems Bulletins: TSB-67,
More informationUTP Cat 5e cable (200 MHz) (PVC sheath)
JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance
More informationThe EMITEX PRODUCT GUIDE 2018/19
The EMITEX PRODUCT GUIDE 2018/19 ABOUT US QUALITY GUARANTEED Emitex was established in 2002, and since then has gone from strength to strength, becoming one of the most recognisable brands in the voice
More informationCat.6/5e UTP Patch Panels with 45 Jack
Cat.6/5e UTP Patch Panels with 45 Jack Index TOOL KITS TOOL WIRING CONNECTORS LAN/DATACOMM INSTRUMENT MISCELLANEOUS POWER TOOLS FIBER OPTICS MAGNIFICATION & Our Cat.6/5e patch panels are used for high
More informationANSI/TIA/EIA-568-B Cabling Standard NOTE
95 ANSI/TIA/EIA-569-A Though the ANSI/TIA/EIA-568-B Standard describes the subsystems of a structured cabling system, the TIA has published a more thorough document called ANSI/TIA/EIA-569-A Commercial
More information3M Category 6 Copper Structured Cabling System
Communication Markets Division 3M Category 6 Copper Structured Cabling System 3M RJ45 Category 6 Jacks UTP PL 3M Copper Patch Cords 3M Copper Patch Panels 3M Faceplates & Wall Outlets 3M Copper Cable 3M
More informationSECTION COMMUNICATIONS BACKBONE CABLING
(NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 GENERAL 1.1 RELATED
More informationInstallation Rate - The installation price shall include all Basic Link cable, connection and wire management hardware required to install a 100 run.
Group 77007 Signal Wiring and Cabling, Fiber Optic Cabling Purchase, Installation and Maintenance Definitions: Bidders Price List with Discount Installation Rate - The installation price shall include
More informationPanduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA
Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation
More informationCat 6 (500 MHz) UTP solid cable (PVC sheath)
JetLan is the only structured cabling system that includes all the passive elements required by the installation or modification of your data networks, as it offers all the options for high performance
More informationTermination for 568A and 568B pin configurations.
1 Termination for 568A and 568B pin configurations. The four twisted pairs in Unshielded Twisted Pair (UTP) cabling terminate in eight-pin modular jacks. There are two different pin configurations permitted
More informationTelecommunications Structured Cabling Systems
Section 18 Telecommunications Structured Cabling Systems 18.1.0 Introduction 18.1.1 Important Codes and Standards 18.1.2 Comparison of ANSI/TIA/EIA, ISO/IEC, and CENELEC Cabling Standards 18.2.0 Major
More informationCopper Riser And Intrabuilding Cabling
Copper Riser And Intrabuilding Cabling PART 1: GENERAL The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable
More informationPCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS
Structured Cabling Solutions PCS PATCH CORDS. HiPerlink 6 Colored Patch Cords- 35,36 HiPerlink 1000 Category 5e Colored Patch Cords- 35,36 Snap-in Icons 36 ScTP Category 5 Patch Cord 37 Category 5 Colored
More informationFamily of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits
SYSTIMAX Structured Cabling Systems Family of Cords Quality Stranded and Solid Cords That Connect Data and Voice Circuits Lucent Technologies Family of Stranded Cords includes 110 patch, modular and adapter
More informationThe following pages contain a guide for the installation
INDEX The goal of this section is to illustrate how Siemon Company products can be used to support some of the most popular and emerging networks on the market. Section Contents 100Base-T....................................
More informationNYS NET PRICE LIST Both 5ESS and DMS100
COST QUOTE : REGIONS 7 & 8 (enter Agency name & install location) CONTR # BN SYSTEMS Purchase PT57142 Digital Centrex Contract Maint. PS57143 1/24/01-1/23/04 1/22/2001 Digital Centrex Contract - Page of
More informationVolition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.
Volition VF-45 Singlemode Socket and Patch Cords IT'S AS EASY AS PLUGGING IN AN RJ-45. The Volition VF-45 Singlemode Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnect products
More informationThe Quality Connection. LEONI QuickLine Class E Cabling Solution
The Quality Connection LEONI QuickLine Class E Cabling Solution QuickLine 2 Content Infrastructure & Datacom Solutions from a single source Shielded solution, keystone 4 Shielded solution, punch-down 5
More informationANSI/TIA/EIA-568-B A P P E N D I X TECHNICAL INFORMATION. Contents ANSI/TIA/EIA-568-B. anixter.com
A The urpose: stablish a generic telecommunications cabling standard that will support a multivendor environment nable the planning and installation of a structured cabling system for commercial buildings
More informationPassive network equipment. Catalog
Passive network equipment Catalog 2018 Table of Contents Cabinets, Open Rack, Server Chassis 4 Single section wall mount cabinets 6 Double section wall mount cabinets 8 Free standing cabinets FF01 series
More information3M Fiber Distribution Units 8400 Series
Communication Markets Division 3M Fiber Distribution Units 400 Series Flexible options to meet growing needs in limited spaces 3M offers a full line of patch panel designs to simplify your cable management
More informationQualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001
Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon, Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design
More informationThe 5500 Series from The Wiremold Company
5500 Nonmetallic Raceway Multi-Channel Surface Nonmetallic Raceway Available Factory Prewired. The 5500 Series from The Wiremold Company provides wire and cable management for data, voice, video, and power
More information3M Telecommunications Solutions for Networks. Volition Network Solutions Product Solution Guide. for Enterprise Networks.
3M Telecommunications Solutions for Networks Volition Network Solutions Product Solution Guide for Enterprise Networks 3Innovation Solutions for Enterprise Networks Everything your Network needs Volition
More informationSECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT. ITS Telecommunications Standards - Specifications Manual for Construction and Renovations
SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT ITS Telecommunications Standards - Specifications Manual for Construction and Renovations Page 1 of 67 TABLE OF CONTENTS UNC Charlotte Information Technology
More informationSiemon PON Fiber Cabling Solutions
Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility
More informationTechnology Standards
June 6, 211 Communications Infrastructure Cabling Services ITB Addenda #1 APPENDIX D, Revision 3.3, dated May 19, 26, is replaced in its entirety, with APPENDIX D, Revision 9, dated April 211, per the
More informationCables and Connectors
Module 2 Cables and Connectors Twisted Pair Two wires that carry the data signals (one conductor carries a positive signal; one carries a negative signal). Two wires are twisted to reduce the effects of
More informationAppendix A-1: PANDUIT Copper Cabling System Technical Information PANDUIT TX5eTM Copper Cabling Conduit Fill Capacity Table
Appendix A-1: PANDUIT Copper Cabling System PANDUIT TX5eTM Copper Cabling Conduit Fill Capacity Table 2009 PANDUIT / Physical Infrastructure Reference Architecture Guide 1.0 Page A-5 Appendix A-1: PANDUIT
More informationNZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling
Page 1 of 7 Title Demonstrate basic knowledge of electronic security data protocols and cabling Level 3 Credits 15 Purpose This unit standard is for electronic security installers engaged in the installation
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords O b D s oc ol e um te en t It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects
More information3 Chapter Introduction. 3.2 Copper Cable
3 Chapter 3 3.1 Introduction The Network Media is the device that physically carries the data from computer to computer. The three major types of network media are: Copper Cable Fiber-Optic Cable Wireless
More informationDivision 27 Master Specification for
Division 27 Master Specification for Information Transport Systems and Spaces December 1, 2018 1 Table of Contents 1 Section 27 10 01 Structured Cabling General Requirements 1.1 Scope 1.2 Approved Contractor
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationCSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90
PATCH PANELS & JACKS Cat6 Patch Panels Cat6 Keystone RJ45 Jack CSC616PP 16 CSRJ456K CSC624PP 24 CSRJ456KB CSC648PP 48 CSRJ456K90 90 Category 6 patch panel exceeds TIA/EIA-568-B.2-1 Category 6 & ISO 11801
More informationAT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T
More informationCabling Infrastructure
Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements
More informationSYSTIMAX GigaSPEED Xpress Solution Design Guidelines
Design Guidelines Issue 2 August 2010 Contents 1.0 Overview 3 2.0 Power Separation 4 3.0 Bonding and Grounding 4 4.0 Administration and Labeling 5 5.0 General Cable Guidelines 5 6.0 Bundling and Alien
More informationWith its tamper-resistant design, the
Dual-Channel 40N2 Series Nonmetallic Raceway Systems CableSmart Series Nonmetallic Raceway With its tamper-resistant design, the CableSmart 40N2 Series Raceway is ideal for schools or office settings,
More informationInstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3
More informationNewark, Delaware Architectural Engineering Senior Thesis Portfolio
Telecommunications System Design The represents the advancement of solar design in our world today. The building itself is an example of this. A Headquarters this dedicated to moving into the future should
More informationCabinet Location Plan FIG.01. Cabinet Symbol Key. Air Handler. Air Handler SAN disk storage. SAN disk storage. option B. Not To Scale.
Cabinet front face - 09 Data Center Storage / Fit-Up Square Feet Square Meters Up Cabinet Symbol Key A Network Row A Network Substation B Server Cabinet A A A A4 A A6 A7 A8 A9 FIG.0 Data Center Square
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects for affordable, high
More informationPlug & Play Universal Systems
Corning Cable Systems Plug & Play Universal Systems create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs) consisting of housings, modules, panels, harnesses, trunks
More informationAT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to
More informationCableSmart Series Nonmetallic Raceway
CableSmart Series Nonmetallic Raceway Dual-Channel 40N2 Series Nonmetallic Raceway System FIBER OPTIC CAT5 Wiremold CableSmart 40N2 Series Raceway is a large capacity nonmetallic raceway system that offers
More informationor
Infinite possibilities for your data center The F-Series TeraFrame T M Cabinet System The F-Series TeraFrame Cabinet System from Chatsworth Products, Inc. (CPI) provides configurable thermal management
More informationVF-45 TM (SG) Ferrule-Less Interconnect Proposal
VF-45 TM (SG) Ferrule-Less Interconnect Proposal IEEE 802.5 Token Ring. November 10-12, 1998 Tad Szostak - 3M Telecom Systems Division 512-984-3847; tszostak1@mmm.com www.3m.com/volition Plug and Socket
More informationThe 400, 800, and 2300 Series, from
400, 800, 2300, 2300D Surface Nonmetallic Raceway Systems For Low Voltage and Power pplications 400, 800, 2300, 2300D Series Raceway Systems The 400, 800, and 2300 Series, from The Wiremold Company, is
More informationOR GN BR SL WT RD BK YW VT RO AQ
New Products 2016 See inside for lots of new products from Excel and contact your local sales representative for price and availability details, or visit our brand new website www.excel-networking.com
More informationVoice Integration Overview
Voice Integration Overview 010.2936 Intelligent voice integration Highest packing density Modular design Efficient and tool-free connection technique Comprehensive product range Ingenious labelling system
More informationSECTION TELEPHONE AND COMPUTER CABLING
SECTION 16700 TELEPHONE AND COMPUTER CABLING PART 1 - GENERAL Verify the computer and telephone cabling standards with MINES CCIT and Telecommunications departments. Telephone and computer lines shall
More informationCompact Module. Category 6 UTP Cabling System
Compact Module Suitable for Gigabit Ethernet applications Shallow design requires minimal back-box depth Interchangeable with all other Euro modules and quarter blanks Fits all standard Euro faceplates
More informationPretium EDGE FX Solutions
Pretium EDGE FX Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE FX Solutions create a fixed-tray fiber optic tip-to-tip solution for Data Centers and
More informationUMass Lowell. October 1, Network and Voice Infrastructure Specifications Prepared by Network Engineering and Network Project Management
UMass Lowell October 1, 2011 Network and Voice Infrastructure Specifications Version 5.1 Prepared by Network Engineering and Network Project Management TABLE OF CONTENTS NETWORK AND VOICE INFRASTRUCTURE
More information3M Telecommunications. Solutions for Networks. Solutions. for Enterprise Networks
3M Telecommunications Solutions for Networks Solutions for Enterprise Networks 3 Contents Page 3: Introduction 4: Copper Jacks 5: Patch Panels 6: Faceplates 7: Copper Cable and Patch Cords 8: Telephony
More informationPretium EDGE HD Solutions A LANscape Pretium Solutions Product
Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Pretium EDGE HD solutions create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs)
More informationThe 5400 Series Raceway from The Wiremold
5400 Nonmetallic Raceway Nonmetallic Raceway with Twin Snap Cover System Available Factory Prewired The 5400 Series Raceway from The Wiremold Company provides wire and cable management for data, voice,
More informationANSI/TIA/EIA-568-B Cabling Standard
83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on
More informationDigital Centrex Contract
Group 77002 PT57148/PS57149 Digital Centrex Contract DMS EQUIPMENT Page of MODEL NUMBER ITEM # ITEM / DESCRIPTION COST INSTALL MAINT Nortel 1 Digital Electronic Series M5008 2 M5008 Digital Multiline se
More informationU-SERIES SPECIFICATION GUIDE
U-SERIES SPECIFICATION GUIDE Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND
More information4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT
Components for TV/SAT, telephone installations and Category 5 DATATEL - TEL DATATEL - CAT5 DATATEL - TV/SAT 7 7 Components for telephone installations FIXED TELEPHONE SOCKETS Type RJ Socket 6/ surface
More informationANSI/TIA/EIA-568-B Cabling Standard
73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before
More informationSECURE NETWORK INFRASTRUCTURE POLICY
Responsible University Administrator: Vice Provost for Academic Affairs Responsible Officer: Chief Information Officer Origination Date: N/A Current Revision Date: 02/19/13 Next Review Date: 02/19/17 End
More informationInformation Transport Systems and Spaces
Division 27 Master Specification for Information Transport Systems and Spaces 1 Table of Contents 1 Section 27 10 01 Structured Cabling General Requirements 1.1 Scope 1.2 Approved Contractor 1.3 Submittals
More informationField Term Plug Installation Guidelines
Field Term Plug Installation Guidelines Today s enterprise networks support a growing number of deployed devices which raise several questions for those who build and maintain the network infrastructure
More informationPHYSICAL INFRASTRUCTURE SYSTEMS
PANZONE ZONE CABLING SYSTEMS Panduit provides a complete line of zone cabling products for open office architecture applications, telecommunication enclosures, data centers, wireless deployments, and network
More informationMetropolis ADM MultiService Mux Compact Shelf
Metropolis ADM MultiService Mux Compact Shelf Engineering and Ordering Information Release 5.0 ED8C938-10 Issue 5 13-May-2005 AN55 Copyright 2005 Lucent Technologies All Rights Reserved A A About This
More informationStandards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More information